Repair / Replacement Of Summer Appliances And Certain E / M Works Under Ge ( East ) Ferozepur Cantt, ferozepur-Punjab

Military Engineer Services-MES has published Repair / Replacement Of Summer Appliances And Certain E / M Works Under Ge ( East ) Ferozepur Cantt. Submission Date for this Tender is 16-05-2022. Air Conditioner Tenders in ferozepur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

31988437
Corrigendum : Repair / Replacement Of Summer Appliances And Certain E / M Works Under Ge ( East ) Ferozepur Cantt
Open Tender
Indian
Punjab
ferozepur
16-05-2022

Tender Details

Repair / Replacement Of Summer Appliances And Certain E / M Works Under Ge ( East ) Ferozepur Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-May-2022 Corrigendum No. 01 Other 16-05-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: Repair/ replacement of summer appliances and certain E/M works under GE (East ) Ferozepur Cantt
Sl. No. Item Description
1WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any type and any make including removed of all other unserviceableparts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , startingcapacitor, over load relay complete all as specifid and directed.
2Supply and Fixing company repaired compressor in lieus of defective compressor to water cooler of 150 ltr capacity including Painting, jointing capillary tube and testing the compressor complete all as specified and directed. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
3All as per Srl No. 2 above but of capacity 60/120 Ltr. complete all as specifid and directed. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
4All as per srl no. 2 above but of capacity 40/80 ltr. complete all as specifid and directed. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
5M & L for servicing of water cooler any size and make including drain outwater cleaning of water tank and cleaning of condersor coil withanti scaling solution complete all as specified and directed.
6Charging of water cooler with F-22/134a gas complete including replacement/filling of compressor oil of Make KAPILA "B" after leakage test and testingof water cooler on full load for 24 hrs continuously at site of any type and any Make of capacity upto 150/150 ltr complete all as specifid and directed.
7S&F and repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
8S&F and spray painting of water cooler of any make of capacity 150/120/80/40 ltrs with two coats synthetic enamelled paint of approved colour as approved by Engineer-in-Charge over a coat of red oxide primer complete including removing / scraping old paint, dust, preparation of surface, filling of metal putty and writing of MES No/ SM No of water cooler with Black paint complete all as specified and directed.
9Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/devidayal after providing "E" class insulation material complete including replacement of unserviceable pad MS clamps, nut and bolt, varnishing & refixing the motor in the watercooler and testing of water cooler complete all as specified and directed.
10Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volt 50 c/s of make MIE/Khaitan/ Crompton Greaves complete all as specified and directed.Note: Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
11S&F in replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 ltr made out of GI Sheet complete all as per existing shape and size complete all as specified and directed
12Supply,fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 Ltr complete all as specifid and directed.
13All as per srl item 12 above but Starting capacitor 80-100 MFD complete all as specifid and directed.
14All as per srl item 12 above butOver load protector as per sample complete all as specifid and directed.
15All as per srl item 12 above but Starting relay 1/8 HP as per sample complete all as specifid and directed.
16All as per srl item 12 above but Plunger type relay as per sample complete all as specifid and directed.
17All as per srl item 12 above but Thermostat switch for water cooler as per sample complete all as specifid and directed.
18All as per srl item 12 above Push cock brass HD chromium plated complete all as specifid and directed.
19All as per srl item 12 above but float valve 15mm/ ½” dia, brass with ball. complete all as specifid and directed.
20All as per srl item 12 above but Rubber hose pipe/ for 1 ½” dia and 1.5 m longdrain pipe. complete all as specifid and directed.
21All as per srl item 12 above but Over load/relay complete box type Y-412 complete all as specifid and directed.
22REFRIGIRATOR 310/165 LTR & DEEP FREEZER 300/400 LTR Taking outexisting compressor unit from the Refrigerator of any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
23Taking outexisting compressor unit from the deep freezerof any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
24Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 310/280/180/165 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
25Supply & Fixing company or manufacturerer"s repaired compressor in lieu of defective compressor to deep freezer of 200/250 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
26Supply & Fixing company or manufacturerer"s repaired compressor in lieu of defective compressor to deep freezer of 300/400 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
27Supply and fixing new compressor to Deep freezer of capacity 200/250 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
28Charging of Deepfreezer/refrigerator with F-12 gas of capacity 400/200/310/165 Ltr or any sizeof any make complete including replacement of compressor oil of make capila "B" and testing complete all as specified and directed.
29Supply,fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
30All as per srl item No 29 above butOver load protector 1/6 HP. Make Hitachi or other equvilent makes as approved by GE complete all as specified and directed.
31All as per srl item No 29 above butThermostat switch with knob - u-50-1018 complete all as specified and directed.
32All as per srl item No 29 above butGlass cover heavy duty of Refrigeratorcapacity 310/165/190 ltrs. complete all as specified and directed.
33All as per srl item No 29 above butFreezer door for whirlpool Refrigerator of Cap 310 ltr. complete all as specified and directed.
34All as per srl item No 29 above but Butter box / any try any type and size as per sample complete suitable for whirlpool/Samsungrefrigarater of Cap 310 Ltr. complete all as specified and directed.
35All as per srl item No 29 above butCrisper tray forany make and size Refrigerater as per sample. complete all as specified and directed.
36All as per srl item No 29 above but Replacement ofthe existing damage choked evaporator from the Refrigerator of Cap 310 Ltr of any Make . complete all as specified and directed.
37All as per srl item No 29 above but Replacement ofthe existing damage choked evaporator from the Refrigerator of Cap180/190/165 Ltr of any Make. complete all as specified and directed.
38Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
39Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motorcomplete all as specified and directed.
40AIR CONDITIONER WINDOW & SPLIT TYPE 1.5 TON CAPACITY Dismantling/Taking out existing unserviceable window typeAir conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc complete all as specified and directed.
41All as per Srl item No 40 above but split type AC of Cap 1.5 Ton. complete all as specifid and directed.
42Supply and fixing company or manufacterers repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton/2.0 capacity including jointing compressor,capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specifid and directed.. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment. Note: Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
43Supply and fixing New compressor in lieu of defective compressor to Air Conditioner split type of 1.5 Ton/2.0 capacity including jointing compressor,capillary, copper tubing as required and testing the compressor complete all as specifid and directed. Note: Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
44Supply and fix in replacement of copper tubing for split type Air conmditioner of 3/8inch or any size required at site all as specified and directed.
45Charging of Air conditioner of capacity 1.5 TR/2.0TR with R-22 gas/as on site complete including replacement/ filling of compressor oil of make. Kapila "B" connecting lead tin coated thumble and installation of AC at site testing on full load for 24 hrs continuously complete all as specified and directed.
46Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similarsize super enameled copper winding wire of make. HTP/Devidayal after providing"E" class insulation material complete includingreplacement of unsv rubber pad MS clamp nut bolt varnishing and refixing themotor in the A/C and testing of Air conditioner complete all as specified and directed. Note:- Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
47Supply & fixing outer unit of spilt type AC of existing make complete all as specified and directed.
48Supply & fixing inner unit of spilt type AC of existing make complete all as specified and directed.
49Supply & fixing PCB unit of spilt type AC of exsting make complete all as specified and directed.
50M&L for repair of existing unserviceablePCB unit of spilt type AC of exsting make complete all as specified and directed.
51Supply & fixing in replacement of condensor coil of window type AC of 1.5 TR Capacity any make complete all as specified and directed.
52Supply & fixing in replacement of condensor coil of split type AC of 1.5 TR Capacity any make complete all as specified and directed
53Supply,fixing and connecting Running capacitor 36 MFD complete all as specified and directed.
54All as per srl item No 53 above but Over Load protector No SR-1622 complete all as specified and directed.
55All as per srl item No 53 above butStarting capacitor 100-120MFD.
56All as per srl item No 53 above butStarting Relay box type 1/8 HP SR-1622complete all as specified and directed.
57All as per srl item No 53above butFront show grill Made of Plastic complete including Air filter complete all as specifid and directed.
58M & L for shifting of airconditioner split type of any make from its original position to another position with andincluding any B & R work reqd and electric work requiredfor it complete all as specified and directed.
59M & L for shifting of air conditioner window type of anymake from its original position to another position with andincluding any B& R work and electric work requiredfor it complete all as specified and directed.
60DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed. Note:-Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
61Taking out existing unserviceable tulu pump (water pump) from the desert cooler supply and fixing connecting new tulu pump 1/20 HP 230 Volt 50 C/S single phase of Make - MIE/Khaitan complete all as specifid and directed.
62Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber padcomplete all as specified and directed.
63S&F in replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly spray paining complete all as specifid and directed.
64S&F in replacement of Desert Cooler sides Shutters set of 3 made of PGI sheet 20 gauge with pad sporting frame of size duly painted complete all as specifid and directed.
65S&F in replacement of capacitor 4 MFD, 230 volts 50 c/s of complete all as specified and directed.
66S&F in replacement of 3 wayPVC distributer complete all as specifid and directed.
67S&F in replacement of selector switch with knob complete all as specifid and directed.
68Taking out unserviceable fan blades of fan motor from the desert cooler and supply and fixing new blade of standard quality and as per existing size complete all as specifid and directed.
69Taking out existing serviceable fan motor and tulu pump from the unserviceablebody of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly spray painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and tulu pump and testing complete all as specified and directed. Note: Test certificate and warrently certificateare mandatroy required with the items of reputed brands.
70M&L for painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust/ complete removal of existing treatment and preparation of surface both inside and out side surfacing complete all as specified and directed.
71Supply and fixing PVC pipe 15mm dia 3 mtr in each cooler complete all as specifid and directed.
72Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed
73S&F in replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler complete all as specifid and directed.
74REPAIR TO VOLTAGE STABILIZER OF CAPACITY5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING: Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning "E" class insulator material varnishing and refixing complete all as specifid and directed.
75Dismantling of printed circuit board complete with condenser choke pre fixer and time delay relay complete all as specifid and directed.
76Supply and fixing volt meter 0-300 volt single phase 230 volt make Bajaj/Crompton/GEC complete all as specifid and directed.
77REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning"E" class insulator material varnishing and refixing complete all as specifid and directed.
78Dismantling of printed circuit board complete with condenser dioel pre fixer of time delay relay complete all as specifid and directed.
79Supply and fixing Bakelite connector in main connection lead complete all as specifid and directed.
80Supply and fixing indicator lamp Neon type (Green Red) complete all as specifid and directed.
81Supply and fixing volt meter 0-300 volts single phase 230 volt make Bajaj/Crompton/GEC complete all as specifid and directed.
82REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt copper winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning "E" class insulator material varnishing and refixing complete all as specifid and directed.
83Supply and fixing volt meter 0-300 volt single phase 230 volt make Bajaj or equivalent standard. Makes of as per approval by GE complete all as specifid and directed.
84REPAIR TO VOLTAGE STABILIZER OF CAPACITY 1 KVA/ 0.5 KVA MAKE - INTEG ELECTRON/ RECOLD COMPRISING THE FOLLOWING Dismantling and opening of main transformer and taking out of old burnt winding wire and rewinding of main transformer with super enameled copper winding wire of make HTP/Devidyal afer provisioning "E" class insulator material, varnishing and refixing including replacement of high and low cut of voltage relay and refixing of time relay delay condenser and testing of voltage stabilizer on full load for 8 Hrs complete all as specifid and directed.
85Supply and fixing indication lamp neon type (Red) complete all as specified and directed.
86Supply and fixing of push type switch complete all as specified and directed.
87Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed.
88Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
89M&L for replacment of unserviceableexisting reverse valve copper tubing as required on site complete all as specifid and directed.
90Servicing and repairing of Aqua Guard water purifier of any cap with following replacment of Make :- Aqua guard. (a) Primery filter
91All as per item No 90 above but UV light complete all as specifid and directed.
92All as per item No 90 above but CarbonCandle complete all as specifid and directed.
93All as per item No 90 above but Carbon stone powder complete all as specifid and directed.
94All as per item No 90 above but Sensor of UV light complete all as specifid and directed.
95All as per item No 90 above butPVC pipe gripper at Primery filter ( set of two) complete all as specifid and directed.
96All as per item No 90 above but Replacement of solonide switchcomplete all as specifid and directed.
97All as per item No 90 above but PVCpipe of Aqua Guard as per exiting sizecomplete all as specifid and directed.
98All as per item No 90 above but Primary filter case with clamps complete all as specifid and directed.
99All as per item No 90 above but Repairing of power circuit board complete all as specifid and directed.