Repair / Maint / Replacement Of Lt Infrastructure Unsv Street Light, Flood Light, High Mast Light, Gate Light, Focus Light And Summer Cooling Appliances In The Area Of Age E / M ( Hosp ) Under Ge E / M Lucknow Repair / Maint / Replacement Of Lt Infr, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Repair / Maint / Replacement Of Lt Infrastructure Unsv Street Light, Flood Light, High Mast Light, Gate Light, Focus Light And Summer Cooling Appliances In The Area Of Age E / M ( Hosp ) Under Ge E / M Lucknow Repair / Maint / Replacement Of Lt Infr. Submission Date for this Tender is 30-05-2022. Halogen Light Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31986866
Corrigendum : Repair / Maint / Replacement Of Lt Infrastructure Unsv Street Light, Flood Light, High Mast Light, Gate Light, Focus Light And Summer Cooling Appliances In The Area Of Age E / M ( Hosp ) Under Ge E / M Lucknow Repair / Maint / Replacement Of Lt Infr
Open Tender
Indian
Uttar Pradesh
lucknow
30-05-2022

Tender Details

Repair / Maint / Replacement Of Lt Infrastructure Unsv Street Light, Flood Light, High Mast Light, Gate Light, Focus Light And Summer Cooling Appliances In The Area Of Age E / M ( Hosp ) Under Ge E / M Lucknow Repair / Maint / Replacement Of Lt Infrastructure Unsv Street Light, Flood Light, High Mast Light, Gate Light, Focus Light And Summer Cooling Appliances In The Area Of Age E / M ( Hosp ) Under Ge E / M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-May-2022 Corrigendum1 Date 23-05-2022
2 12-May-2022 Corrigendum2 Financial Bid 23-05-2022
3 12-May-2022 Corrigendum2 BOQ 23-05-2022
4 23-May-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-05-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT/REPLACEMENT OF LT INFRASTRUCTURE UNSV STREET LIGHT, FLOOD LIGHT, HIGH MAST LIGHT, GATE LIGHT, FOCUS LIGHT AND REPAIR/MAINT OF SUMMER APPLIANCES IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW.
Sl. No. Item Description
1Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cablecrossed linked polyethylene ( XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :-Excavation, earth work, sand cushioning, protection bricks/ tiles/ block andpipe shall be measured and paid separately under appropriate items.
2All as per item No 01 above but of size 10 Sqmm 4 core
3All as per item No 01 above but of size 16 Sqmm 4 core
4All as per item No 01 above but of size 25 Sqmm 3.5 core
5All as per item No 01 above but of size 35 Sqmm 3.5 core
6All as per item No 01 above but of size 50 Sqmm 3.5 core
7All as per item No 01 above but of size 70 sq mm 3.5 core
8All as per item No 01 above but of size 95 Sqmm 3.5 core
9All as per item No 01 above but of size120 Sqmm 3.5 core
10All as per item No 01 above but of size 240 Sqmm 3.5 core
11Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/loose soilcomplete all as specified and directed.
12Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
13Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
14Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
15M&L laying fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
16Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
17S & F GI tubing "Light" grade 40 MM for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes of following sizes, complete all as specified and directed.
18All as per item No 17 above but size 50 mm bore dia
19All as per item No 17 above but size 80 mm bore dia
20Labour for taking out the unserviceable / faulty cable after meggering, finding the fault, cutting the cable , jointing with jointing kitusing extra cable if required ,relaying of cables upto 300sqmm 3.5 core ,connecting,rate includedof excavation works, using old bricks complete all as specified and as directed. Note:, cable joints will be measured and paid seperatly under respectrive item of schedule.
21Material & Labour for preparation of old painted surface of steel tubular pole 9 meter long above coping) and applying two coat of aluminium paint, making of strip of 300mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
22Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in black colour background of 80 mm hight around the radius of pole and complete all as specified and directed.
23Supplying and fixing in repair flat twin core ,1.5sqmm nominal cross sectional areamultistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy dutycable PVC insulatedand PVC sheathed complete all as specified and directed.
24Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional areamultistrandedaluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy dutycable PVC insulatedand PVC sheathedcomplete all as specified and directed.
25Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional areamultistrandedaluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and directed.
26M&L for old painted steel surface or iron surfaces of LT FPB of various size by scraping with steel wire brush/scrapper emery paper etc and applying one coat of synthatic enameled siemens grey/existing colour (painting shall be done by spray machine ) including hinge welding and fiting of newtwo number door for front and backside for thickness upto 3.15mm & size as per existing panel ofthe LT FBP door matching with the LT FBP including panel repair complete all as specified and directed.
27MCCBs four pole 16 KA, fixed typeincl taking out unserviceable MCCB"s and connecting,of capacityupto 100 AMPS complete all as specified and directed.
28MCCBs four pole 16 KA, fixed typeincl taking out unserviceable MCCB"s and connecting,of capacity125 AMPScomplete all as specified and directed.
29MCCBs four pole 16 KA, fixed typeincl taking out unserviceable MCCB"s and connecting,of capacity160AMPScomplete all as specified and directed.
30MCCBs four pole 25 KA, fixed typeincl taking out unserviceable MCCB"s and connecting,of capacity250AMPScomplete all as specified and directed.
31MCCBs four pole 36 KA, fixed typeincl taking out unserviceable MCCB"s and connecting,of capacity400AMPScomplete all as specified and directed.
32Digital type Volt meter , 3 ph , class 1 including taking down unserviceable voltmeter, complete all as specified and directed.
33Digital type Ammeter 3 ph , 5 Amps , class 1 including taking down unserviceable ammeter, complete all as specified and directed.
34Indicator lamps (LED Type) including taking down unserviceableindicator lampsall, complete all as specified and directed.
35S & F in repMCB’s singlepole with neutral, 6 to 32 Amps, 250 volts with"B curve, fixed in existing PVC box including connecting complete all as specified and directed.
36M&L for plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as in copping of polescomplete all as specified and directed.
37Disconnecting the LT cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5/4 core 10 to 16 sq mm, complete all as specified and directed.
38All as per item No 37 above but size 25 to 50 Sqmm
39All as per item No 37 above but size 70 to 120 Sqmm
40All as per item No 37 above but size 150 to 185 Sqmm
41All as per item No 37 above but size 240 to 300 Sqmm
42Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps withsynthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paintcomplete all as specified and directed.
43S&FMS Junction Box made of 1.6 mm thick MS sheet of size 300 x 200 x 150 mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bus bar 100 Amps, mounted on porcelain insulatorincluding MCB SP 10Amp , 10 KA-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable sizeFI clamp nut bolts and washer including dulypainted with powder coated paint complete including required size and length of copper conductor cable and making connections completeall as specified and directed.
44S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed Make havells or equivalent complete all as specified and directed.
45S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle typein sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed.
46S & FOff load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and directed.
47Supply and fixing new generation ,energy saving ,environment friendlyLEDGATE LIGHT fitting,fully castaluminium body finish with polyeurethene paint with acryilic window cover with B22 brass holdersuitable for 15 to20watt led bulbas light sopurceincluding making connections complete all as specified and directed. Make- MEPROcat part no. PTL-0002 OR EQUIVALATS MAKE as spacified and directed by engineer in charge
48Supply and fixing new generation ,energy saving ,environment friendlyPOST TOP LANTERNfitting, aluminium spun lamdscape luminaires with high power LED25 watt as light sopurceincluding making connections complete all as specified and directed. Make- havells cat part no. RUBYPT25WLED830SSYMTOPC OR EQUIVALATS MAKE
49Dismantling & taking out old/unsv LT panel board, supply installation testing and commisioning ofLT outdooroutd PanelOF size – 1.5 x 1.0 x 0.50 mtroutdoor typefactory madepedastal type outerfabricated outof 3.15 mmCRCA sheet and inner sheetof MS black sheet and slopy roof and spray paintingtwo coat insiade and outsidewith synthetick enamle paintof approved shade over a coat of red oxide primer locking arrangementcomprise 50 mm size godredge brasspad lock with duplicate keys two earthly terminal suitable cablegland for all incoming and outgoing cablegrouting of feeder pillerbox 40cm above ground level by providing 90 cm longangle iron of size 50x50x6 mm welded on all the for cornerembeded in PCC 1:2:4using20 mm stone agregrateup to 50 cm deepincluding connection all exisiting cable with mCCB terminal all as specified and directed by EIC at the site requirment complete includingthe following component:-(gynology dpt front ) 1) incoming (i) MCCB4P 250Amps , 36 KA -01 Nos. (2) Outgiong (i) MCCBs 4P 100 Amps , 25 KA -05 nos (ii) MCCBs 4P 63Amps, 25 KA-02nos (3)Accessories - (a) copper bus bar rating400 Amps -04 Nos . (b) digital Volt meter 0-500V with selector switch-01 No, (c )digital Amp meter 0-300 amp with CT and selector switch-01 No, (d) Indicating lamp-01 Set (LED Type)
50M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
51M&L Earthing complete with Copper earthPlate electrode 60x60cmx3.15mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, Including connected to copper strip 20x3mmlead (upto 7.5 Mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion.ith salt to a packed thickness of 15 cm all around the plate, and including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
52Dismantling and removing existing unsv street light/ flood light MH/HPSVfittings of any type and any capacity from street light poles any hieghtand high mast light poleafter disconnecteingof electrical connectioncomplete all as specified and directed.
53Supply and Fixing, connecting and testing energy saving LED street light fittings 35Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
54Supply and Fixing, connecting and testing energy saving LED street light fittings 45 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
55Supply and Fixing, connecting and testing energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracketcomplete all as specified and directed.
56Supply and Fixing, connecting and testing energy saving LED street light fittings of 120Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
57Supply and Fixing, connecting and testing energy saving LED street light fittings of 90 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light polesand bracket complete all as specified and directed.
58Fixing in replacement GI bracket for street light fittings fabricated with GI tubing 40mm dia "lightgrade" 1.5m long and bending to angle of 120 degree including mild steel clampof suitable size with two coat aluminium paint suitable for fixing on PCC/steel poles complete all as specified and directed.
59Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 120 Watt pressure die cast aluminium housing and IP66 protection including XLPEarmoured cable 2 core 4 Sqmmup to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
60Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 70 Watt pressure die cast aluminium housing and IP66 protection including XLPEarmoured cable 2 core 4 Sqmmup to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
61Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 150 Watt pressure die cast aluminium housing and IP66 protection including XLPEarmoured cable 2 core 4 Sqmmup to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
62Lowering the high mast light from height of 16 to 25 mtr and repairs to the extent by removing connections from the system, checking of unserviceable spare parts and serviceable parts ,replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location and tesing complete all as specified and directed. Note : (a) Spares required for repair shall be measured and paid separately as supply only items here-in-after (b) The contractor shall provide all type and safety equipment & other tools required at site to electrician for maintenance of light (c) In case any accident/injury of any person deputed by contractor shall be held responsible for setting all claims/compensation. (d) all other item also included in the works which not catered in items
63Supply only gear box as per existing size, capacity and make CROMPTON GREEVES
64Supply only motor as per existing size,capacity and make CROMPTON GREEVES
65Supply only controll switch as per existing size, capacity and make CROMPTON GREEVES
66Supply, fixing, connecting and testing energy efficient LED flood light fittings of200Watt pressure die cast aluminium housing and IP66 protectionwith complete all as specified and directed.
67Dismantling and Supply, installation and testing of outdoor LT PanelOF size – 1.5 x 1.0 x 0.50 mtroutdoor typefactory madepedastal type outerfabricated outof 3.15 mmCRCA sheet and inner sheetof MS black sheet and slopy roof and spray paintingtwo coat inside and outsidewith synthetick enamle paintof approved shade over a coat of red oxide primer locking arrangementcomprise 50 mm size godredge brasspad lock with duplicate keys two earthly terminal suitable cablegland for all incoming and outgoing cablegrouting of feeder pillerbox 40cm above ground level by providing 90 cm longangle iron of size 50x50x6 mm welded on all the for cornerembeded in PCC 1:2:4using20 mm stone agregrateup to 50 cm deepincluding connection all exisiting cable with mCCB terminal all as specified and directed by EIC at the site requirment complete includingthe following component:- (1) incoming (i) MCCB4P 250Amps , 35 KA -01 Nos. (2) Outgiong (i) MCCBs4P Thermal magnitic & fixed type160 Amps, 35 KA-02 nos(ii) MCCBs4P Thermal magnitic & fixed type 63 Amps, 25 KA-02 nos (3)Accessories (a) copper bus bar rating500 Amps -04 Nos . (b) digital Volt meter 0-500V with selector switch-01 No, (c )digital Amp meter 0-300 amp with CT and selector switch-01 No, (d) Indicating lamp-01 Set (LED Type) set of three
68Dismantling and Supply, testing and commissioning weather and vermin proof LT feeder pillar box (Panel board) factory fabricated out door cubical/kiosk type totally enclosed made out of 3.15 mm thick sheet metal enclosure of as per 15:5039/1983 partially type tested with angle iron frame of M.S. angle 50x50x6mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes of prevent ingress of water/vermin etc inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour, including earth,pcc works as directed with the following accessories :- (a) MCCB 4 P 160 Amp 16 KA with thermal & magnatic release-01 Nos (b) Indicator R,Y,B - 3 Nos (c) Digital voltmeter with selector switch 0-500 Volts-01 No (d) Digital Ammeter with slector switch with suitable size CTs (0-300 ) -01 Nos (e) TPN aluminium bus bar of suitable capacity with pvc slip with 6 Nos hole for out going cable entry
69Material and Labour for servicing of split type AC"s of capacity 1.5/2 TR comprising of the following tasks installed at different locations includingtesting complete all as specified and directed. (a) Inspecting and checking the Indoor/outdoor units for noise free operation. (b)Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower. (d) Greasing/Oiling of condenser fan motor and blower motor. (e) Checking for any refrigerant leakage by pressure testing and repair it. (f) Checking for serviceability of remote control unit NOTE - Sevicing of each AC should be done twice in a entire contract period.
70All as per item No 69 above but 1.5/2.0 TR Window type AC.
71Supply and fixed in repairs of starting capacitor of 80-100 /100/120/120/150 Mfd capacity in plastic / metal container complete all as specified and directed.
72Supply and fixed in repairs of running capacitor 36 Mfd capacity in plastic container complete all as specified and directed.
73Supply and fixed in repairs of running capacitor 50+2/50+6 Mfd capacity in plastic container complete all as specified and directed.
74Supply and fixed in repairs starting relay for 1.5 TR /2 TR compressor complete all as specified and directed.
75Supply and fixed in repairs over load protector for 1.5 TR / 2TR compressor complete all as specified and directed.
76Supply and fixed in repairs Thermostate switch for 1.5 TR / 2 TR split AC complete all as specified and directed.
77Supply and fixed in repairs Swing Motor for 1.5 TR / 2 TR Indoor unit complete all as specified and directed.
78Supply and fixed in repairs reverse cycle solenoid valve in split/window type AC 1.5 /2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and directed.
79Supply and fixed in repairs suction copper pipe line heavy duty ½"" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity complete all as specified and directed.
80Supply and fixed in repairs discharge copper pipe line heavy duty 1/4" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 TR 2 TR capacity complete all as specified and directed.
81Supply and fixed in repairsPVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall complete all as specified and directed.
82Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
83Dismantling of burnt blower motor of 1.5 TR /2 TR split AC ( indoor unit) and supply & fixing blower motor of same manufacturer of AC of Make of AC Carrier/Voltas /Blue staras per sample complete all as specified and directed.
84Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split/windowtype AC unit with Refrigerant Gas compatible to R-22 typein required Qty complete all as specified and directed.
85Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas non CFC compatible to R- 710 typeor as eqvlntin required Qty complete all as specified and directed.
86Supply and fixed in repairs ofsuction valve size 1/2" complete all as specified and directed .
87Supply and fixed in repairs of discharge valve size 1/4" complete all as specified and directed.
88Supply and fixed in repairs ofair filter made out Nylon suitable for 1.5 TR split AC capacity air conditioners of any Make and model complete all as specified and directed.
89Carrying out pressure leak test of split ACs 1.5 / 2.0 TRby Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
90Carrying out pressure leak test of 1.5 TR windowAC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe transporting & carrying out Tools and Plant required at sitecomplete all as specified and directed.
91Supply & Fixing the new remote control unit (cordless)as per existing model for 1.5/2 TR split type A/C unit complete all as specified and directed.
92S&F Compressor rotary suitable for reversible cycle split type AC 1.5 TR (Original sealed unit is to supply ) of Make Blue Star, Videocon, Samsung, or its equivalent of other specified make as approved by GE.
93S&F Compressor rotary suitable for reversible cycle split type AC 2.0 TR (Original sealed unit is to supply ) of Make Blue Star, Videocon, Samsung, or its equivalent of other specified make as approved by GE.
94S & F in repairs sheet metal enclosure with metallic socket and MCB single pole 32 Amp and metallic plug top connected from mains to AC complete all as specified and directed.
95S & F repairs metallic plug top of 16 Amps connected from mains to AC complete all as specified and directed.
96Supply and fixing in repairs front grill quantity for window AC of 1.5 TR /2TR of Make National / Cosmo complete all as specified and directed.
97Supply and fixed in repairs ofmild steel stand factory fabricatedmadeout of MS sheet 18 gauge floor/wall mounted, duly powder coated including nuts ,bolt, washer, fastners etc suitable for mounting of out door unit of split AC 1.5/2.0 TR at locationscomplete all as specified and directed.
98Dismantling of indoor/out door unit of split type A/Cs of 1.5/2.0 TR capacity from their original locations and shifting it to other locations including servicing/overhauling of indoor/out door units,top up of refrigerant gas as required quantity and refixing it to locations where directed and making necessory electrical connection/connecting copper tubing of suction/discharge line and testing it upto entire satisfaction of Engineer-in-charge.
99Dismantling of defective worn out wiring of window/splitAC of capacity 2.0 TRTR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and remote hand set to shut /match the existing system complete all as specified and directed. (Make of AC and remote :- Carrier /LG -HI SERIES).
100Supply and fixed in repairs of PVC insulated three core stranded copper cable of size 80/20 complete all as specified and directed.
101Supply and fixed in repairsSingle phase Compact cooling fan motor assembly 230 volt 50 Hz 1/6HP Along with guard etc for 2 TRwalk-in-coolercomplete all as specified and directed.
102Repair & maintenance of water coolers of any capacity comprising of the following tasks at different location complete all as specified and directed. (a) Inspection, taking down, opening, dismantling, descaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning. (c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (j) Testing of water cooler after repair.
103All as per item No 102 above but refrigerator of capacity 165/286/300/310 litre capacity charging of refrigerant gas R-22/R-134
104S&F in repairs starting relay, open type for refrigerator of capacity 190/300/310 litres complete all as specified and directed.
105S & F in repairs of over load protector for 1/6 HP refrigerator of capacity 190/300 /310 litres complete all as specified and directed.
106S & F in repairsthermostat defrost type for refrigerator complete all as specified and directed.
107S & F in repairs door gasketfor refrigerator of 165 / 170 / 180 litres capacities, any make complete all as specified and directed.
108All as per item No 107 above but 286 /300 /310 litres capacities
109S & F in repairs freezer door with spring for Refrigerator of 165 / 170 / 180 litres capacities complete all as specified and directed.
110All as per item No 109 above but for 286 /300 / 310 litres capacities
111M&L for renewal of sealed unit Compressor ofwater coolerof capacities 60/120 ltrduly charged with refrigerent non CFC charged complete all as specified and directed (Make-Kalvinator/ Whirlpool)
112M&L for renewal of sealed unit Compressor water coolerof capacities 150ltr capacities duly charged with refrigerent non CFC charged complete all as specified and directed (Make-Kalvinator/ Whirlpool)
113Dismantling of top cover of water cooler of followingcapacity and S&F new top cover of following sizes 68cm x 61cm made out of 22 gauge GI sheetcomprising CP MS handle of suitable size, PVC gasket, inner lining of glass wool of density not less than 48 kg/cum, locking arrangement, aluminium hinges etc and spray painting the top cover to match with the existing complete all as specified and directed
114All as per item No 113 above but new top cover of size 72.5cm x 55cm x 3mm
115Supply & fixing (in repairs) CP Brass push cock(inner or outer threaded) of 15 mm bore size complete all as specified and directed.
116S&F in repairs float valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified and directed.
117Supply & fixing (in repairs)running capacitor 25 mfd(conforming to IS:2993 - 1975) AC 440 volts in plastic container complete all as specified and directed.
118All as per item No 117 above but 36 mfd
119All as per item No 117 above but 50 mfd
120Supply & fixing (in repairs) overload protector for 1.00 TR compressor complete all as specified and directed.
121Dismantling of existing repaireabledeep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor"s workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
122Supply and Fixing in repairs of starting relay for 190/300 Ltr. Capacity deep freezer complete all as specified and directed.
123Supply and Fixing in repairs of starting relay for 190/ 210 Ltr. Capacity deep freezer complete all as specified and directed.
124Supply and Fixing in repairs of over load protector suitable for 210 / 300 Ltr deep freezer complete all as specified and directed.
125S&F in repairs of running capacitor for /190210 / 300 Ltr capacity deep freezer complete all as specified and directed.
126S&F in repairs of thermostate suitable for 190/210 / 300 Ltr. Capacity deep freezer complete all as specified and directed.
127S&F in repairs of starting capacitor for 210 / 300 Ltr. Capacity deep freezer complete all as specified and directed.
128Taking down defective compressor of 310 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar capacity deep freezer of any Make and depositing same in AGE E/M (HOSP) yard and Supplying and fixing sealed unit compressor as specified here underincluding brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing complete all as specified and directed.
129All as per item No 128 above but 240 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
130Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
131Dismantling of liquid line filter of refrigerator of190 litre capacitiesand supply & fixing new liquid filter , assembling of filter by replacing bolts & gasket etc complete all as specified and directed.
132Taking out defective blower motor and transporting blower motor of any make and capacity 1/16 HP toworkshop and dismanteling the burnt winding and rewinding blower motor with existing size of supper enamelled copper winding wire including insulation, varnishing, greasing and testing complete and transporting back to storeyard complete all as specified and directed.
133Taking down desert cooler of any size and make from existing position i.e. stand/pillar installed at any location of building(s) including making arrangements for loading/ unloading such as rope and ladders etc.for repairs and taking back after repairs & reinstalling in its positionand testing complete all as specified and directed. (Note : Necessaryrepairs and renewalof parts will be measured and paid for separately under appropriate items(s)
134Repairing of leakage of tank by brazing/solderingof any size of desert cooler, testing the leakage water complete all as specified and directed.
135S&F in repairs of of control switch/dimmer electronic 600 watt complete all as specified and directed.
136S&F in repairs of set of panels made out of PGI sheet22 gauge thick with wood wool pads, in required quantity duly filled complete as per sample and complete all as specified and directed.
137Taking out defective pumps vertical/ horizontal type from desert cooler and S&Fnew Horizontal pump/ vertical pump of desert cooler andfixing in positioncomplete all as specified and directed. Make Bajaj/ Crompton
138S&F in repairs of wood wool pad of desert coolers suitable for 450 mm/500 mm sweep complete all as specified and directed.
139S&F in repairs of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"sweep size suitable for desert cooler complete all as specified and directed. (Make:- Jyoti / Champion / Summer Cool)
140Replacing capacitor single phase A/C 250 volts for ceiling fan/kit fan motor and blower motor 2.5 Mfd, complete all as specified and directed.
141All as per item No 140 above but 4.00 Mfd
142S&F (in repair) Gun metal globe or gate valve size 15mm dia, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
143S&F in repairs ofPVC connection 15 mm dia with brass ferule both and length 600 mm size 15mm dia complete all as specified and directed.Make Prayag/ Polytuf
144Collecting defective /unserviceable Heat blowerof any capicity& make and size AGE E/Mhosp yard and carrying to Contractor"s workshop, for repair serivicuing and maintopening and cutting worntout blower motor and unserviceable heating element of any make and capacity230V, 50 Hz, cleaningproperly internally and externally and servicing complete all as specified and directed.
145Supply& Fixing Selector cum thermostateswitch for heat bloweras per existing make and model complete all as specified and directed.
146Supply& FixingBlower motor of 0.50 HPwith standas per existing make and model complete all as specified and directed.
147Supply and fix HEPA filtersuatable for air purifier Healthy airfilter effectively filters out partcicles, dust, allergens and bacteria. roduct dimensions (W x D x H)240 x 30 x 295mm. complete all as specified and directed.Make -phhilips or eqvlnt
148Supply and fix air purifierPCBdigital type for air purifieras per existing modleand make complete all as specified and directed.