}

Procurement Of Rate Of Materials- 1 M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 3 M337jute 4 M922g.M. Ferrules 5, dumka-Jharkhand

Drinking Water And Sanitation Department has published Procurement Of Rate Of Materials- 1 M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 3 M337jute 4 M922g.M. Ferrules 5. Submission Date for this Tender is 04-05-2022. Kitchen Equipment Tenders in dumka Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31985506
Procurement Of Rate Of Materials- 1 M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 3 M337jute 4 M922g.M. Ferrules 5
Open Tender
Indian
Jharkhand
dumka
04-05-2022

Tender Details

Procurement Of Rate Of Materials- 1 M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 3 M337jute 4 M922g.M. Ferrules 5 ( I ) 8 Mm Dia Wt. Not Less Than 400 Gms 6 ( Ii ) 10 Mm Dia Wt. Not Less Than 400 Gms 7 ( Iii ) 15 Mm Dia Wt. Not Less Than 400 Gms 8 ( Iv ) 20 Mm Dia Wt. Not Less Than 600 Gms 9 ( V ) 25 Mm Dia Wt. Not Less Than 900 Gms 10 M923stop Cocks 11 ( I ) 15 Mm Brass Stop Cock Wt. Not Less Than 300 Gms 12 ( Ii ) 20 Mm Brass Stop Cock Wt. Not Less Than 400 Gms 13 ( Iii ) 25 Mm Brass Stop Cock Wt. Not Less Than 575 Gms 14 ( Iv ) 32 Mm Brass Stop Cock Wt. Not Less Than 850 Gms 15 ( V ) 40 Mm Brass Stop Cock Wt. Not Less Than 1.15 Kg 16 ( Vi ) 50 Mm Brass Stop Cock Wt. Not Less Than 2.15 Kg 17 ( Vii ) 15 Mm Dia C.I. Body Brass Working Part Stop Cock. 18 ( Viii ) 20 Mm Dia C.I. Body Brass Working Part Stop Cock. 19 ( Ix ) 25 Mm Dia C.I. Body Brass Working Part Stop Cock. 20 M924g.M. Full Way Valve 21 ( I ) 15 Mm Dia Wt. Not Less Than 300 Gms Without Wheel 22 ( Ii ) 20 Mm Dia Wt. Not Less Than 400 Gms Without Wheel 23 ( Iii ) 25 Mm Dia Wt. Not Less Than 500 Gms Without Wheel 24 ( Iv ) 32 Mm Dia Wt. Not Less Than 700 Gms Without Wheel 25 ( V ) 40 Mm Dia Wt. Not Less Than 1.0 Kg Without Wheel 26 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.4 Kg Without Wheel 27 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.8 Kg Without Wheel 28 ( Viii ) 80 Mm Dia Wt. Not Less Than 2.5 Kg Without Wheel 29 M925g.M. Non Return Valve Vertical 30 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 31 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 32 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 33 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 34 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 35 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 36 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 37 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 38 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 39 M926g.M. Non Return Valve Horizontal 40 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 41 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 42 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 43 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 44 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 45 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 46 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 47 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 48 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 49 M927 Cocks 50 ( I ) 15 Mm Dia G.M. Bib Cock Wt. Not Less Than 300 Gms 51 ( Ii ) 15 Mm Dia Brass Bib Cock Wt. Not Less Than 400 Gms 52 ( Iii ) 15 Mm Dia C.I. Bib Cock Wt. Not Less Than 400 Gms 53 ( Iv ) 15 Mm Dia C.I. Body Brass Working Part Spray Painted Bib Cock Wt. Not Less Than 400 Gms 54 ( V ) 15 Mm Dia C.I. Brass Pillar Cock Cock Wt. Not Less Than 400 Gms 55 ( Vi ) 15 Mm C.I. Plug Cock Ordinary 56 ( Vii ) 15 Mm C.I. Push Cock Ordinary 57 M928chromium Plated Brass Fittings 58 ( I ) C.P. Shower Rose 100 Mm Dia 59 ( Ii ) C.P. Shower Rose 125 Mm Dia 60 ( Iii ) P.V.C. Shower Rose 150 Mm Dia 61 ( Iv ) P.V.C Shower Rose 125 Mm Dia 62 M929connection Pipe 63 ( I ) 15 Mm Dia X 30 Cm. Long Lead Connection Pipe With Brass Fittings. 64 ( Ii ) 15 Mm Dia X 45 Cm. Long Lead Connection Pipe With Brass Fittings. 65 ( Iii ) 15 Mm Dia X 30 Cm. Long Pvc Connection Pipe With Brass Fittings. 66 ( Iv ) 15 Mm Dia X 45 Cm. Long Pvc Connection Pipe Withbrass Fittings. 67 M930g.I. Fittings ( Conforming To I.S. - 1879 ) Isi Marked 68 [ A ] G.I. Bend 69 ( I ) 15 Mm 70 ( Ii ) 20 Mm 71 ( Iii ) 25 Mm 72 ( Iv ) 32 Mm 73 ( V ) 40 Mm 74 ( Vi ) 50 Mm 75 ( Vii ) 65 Mm 76 ( Viii ) 80 Mm 77 ( Ix ) 100 Mm 78 ( X ) 125 Mm 79 ( Xi ) 150 Mm 80 [ B ] Elbow Of The Following Sizes 81 ( I ) 15 Mm 82 ( Ii ) 20 Mm 83 ( Iii ) 25 Mm 84 ( Iv ) 32 Mm 85 ( V ) 40 Mm 86 ( Vi ) 50 Mm 87 ( Vii ) 65 Mm 88 ( Viii ) 80 Mm 89 ( Ix ) 100 Mm 90 ( X ) 125 Mm 91 ( Xi ) 150 Mm 92 [ C ] Tee Plain Of The Following Sizes 93 ( I ) 15 Mm 94 ( Ii ) 20 Mm 95 ( Iii ) 25 Mm 96 ( Iv ) 32 Mm 97 ( V ) 40 Mm 98 ( Vi ) 50 Mm 99 ( Vii ) 65 Mm 100 ( Viii ) 80 Mm 101 ( Ix ) 100 Mm 102 ( X ) 125 Mm 103 ( Xi ) 150 Mm 104 [ D ] Reducing Tee Plain Of The Following Sizes ( Taking Larger Dimension ) 105 ( I ) 20 Mm 106 ( Ii ) 25 Mm 107 ( Iii ) 32 Mm 108 ( Iv ) 40 Mm 109 ( V ) 50 Mm 110 ( Vi ) 65 Mm 111 ( Vii ) 80 Mm 112 ( Viii ) 100 Mm 113 ( Ix ) 125 Mm 114 ( X ) 150 Mm 115 [ E ] Socket Plain Of The Following Size ( Taking Larger Dimension ) 116 ( I ) 15 Mm 117 ( Ii ) 20 Mm 118 ( Iii ) 25 Mm 119 ( Iv ) 32 Mm 120 ( V ) 40 Mm 121 ( Vi ) 50 Mm 122 ( Vii ) 65 Mm 123 ( Viii ) 80 Mm 124 ( Ix ) 100 Mm 125 ( X ) 125 Mm 126 ( Xi ) 150 Mm 127 [ F ] Reducing Socket Plain Of The Following Sizes ( Taking Larger Dimension ) 128 ( I ) 20 Mm 129 ( Ii ) 25 Mm 130 ( Iii ) 32 Mm 131 ( Iv ) 40 Mm 132 ( V ) 50 Mm 133 ( Vi ) 65 Mm 134 ( Vii ) 80 Mm 135 ( Viii ) 100 Mm 136 ( Ix ) 125 Mm 137 ( X ) 150 Mm 138 [ G ] Union Socket Of The Following Sizes 139 ( I ) 15 Mm 140 ( Ii ) 20 Mm 141 ( Iii ) 25 Mm 142 ( Iv ) 32 Mm 143 ( V ) 40 Mm 144 ( Vi ) 50 Mm 145 ( Vii ) 65 Mm 146 ( Viii ) 80 Mm 147 ( Ix ) 100 Mm 148 ( X ) 125 Mm 149 ( Xi ) 150 Mm 150 [ H ] Plugs Of The Following Sizes 151 ( I ) 15 Mm 152 ( Ii ) 20 Mm 153 ( Iii ) 25 Mm 154 ( Iv ) 32 Mm 155 ( V ) 40 Mm 156 ( Vi ) 50 Mm 157 ( Vii ) 65 Mm 158 ( Viii ) 80 Mm 159 ( Ix ) 100 Mm 160 ( X ) 125 Mm 161 ( Xi ) 150 Mm 162 [ I ] Jam Nuts Of The Following Sizes 163 ( I ) 15 Mm 164 ( Ii ) 20 Mm 165 ( Iii ) 25 Mm 166 ( Iv ) 32 Mm 167 ( V ) 40 Mm 168 ( Vi ) 50 Mm 169 ( Vii ) 65 Mm 170 ( Viii ) 80 Mm 171 ( Ix ) 100 Mm 172 ( X ) 125 Mm 173 ( Xi ) 150 Mm 174 [ J ] G.I. Nipple Of The Following Sizes 175 ( I ) 15 Mm Dia X 100 Mm Long 176 ( Ii ) 20 Mm Dia X 100 Mm Long 177 ( Iii ) 25 Mm Dia X 100 Mm Long 178 ( Iv ) 32Mm Dia X 100 Mm Long 179 ( V ) 40 Mm Dia X 100 Mm Long 180 ( Vi ) 50 Mm Dia X 100 Mm Long 181 ( Vii ) 65 Mm Dia X 100 Mm Long 182 ( Viii ) 80 Mm Dia X 100 Mm Long 183 ( Ix ) 100 Mm Dia X 100 Mm Long 184 [ K ] G.I. Pipes Midium ( Tata Mark ) Or Equivalent As Per Is-1239 ( Part-01 ) / 2004 Isi Marked / Medium Quality 185 ( I ) 15 Mm Dia 186 ( Ii ) 20 Mm Dia 187 ( Iii ) 25 Mm Dia 188 ( Iv ) 32 Mm Dia 189 ( V ) 40 Mm Dia 190 ( Vii ) 65 Mm Dia 191 M931mirrors 192 ( A ) Mirror Of 6 Mm Thick Plain Glass 600 Mm X 450 Mm Beveled Edge Mirror Includingc.P. Brass Revolving Fittings 3 Mm Plywood Boardand C.P. Hinges Etc.To Fix The Mirror 193 ( B ) -Do- 450 Mm X 300 Mm -Do- 194 M932 ( A ) Glass Shelf 600 Mm X 125 Mm With C.P. Brass Rail 195 ( B ) -Do- 450 Mm X 125 Mm -Do- 196 M933 ( A ) C.P. Brass Towel Rail 20 Mm X 600 Mm With Bracket All Complete 197 ( B ) Anodized Aluminum 20 Mm X 600 Mm Towel Rail Complete With Brackets 198 M934c.P. Brass Soap Dish Medium Quality With Screw Andhinges Etc. 199 M935c.P. Liquid Soap Solution Holder 200 M936vitreous White Glazed Indian Water Closet Of Hindustan / Parry Ware / Cera / Naycer Or Anyotherequivalent Make 201 ( A ) 580 Mm Long 202 ( B ) 510 Mm Long 203 ( C ) 450 Mm Long 204 ( D ) 510 Mm Long White Glazed Fiber I.W.C 205 M937pair Of Vetreous White Glazed Foot Rest Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 206 M93815 Liters Capacity Pull And Let Go High Level C.I. Cistern Complete With Ball Cock And A Pair Of Bracket 207 M939 ( A ) 12.5 Liters Lowdown C.I. Cistern 208 ( B ) 10.0 Liters Capacity P.V.C. Low Design Cistern 209 M940 ( A ) White Glazed Vitreous E.W.C With P Trap Orany Other Equivalent Make 210 ( B ) E.W.C With S Trap 400 Mm High Of Hindustan / Parry Ware / Cera / Naycear Or Any Other Equivalent Make 211 ( C ) Black / White Plastic Seat For E.W.C -Do- As Above. 212 M941 ( A ) White Glazed Vitreous Earthen Were Urinal Flat Back Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 600 Mm X 350 Mm Size 213 ( B ) -Do- Squatting Small 450 Mm X 350 Mm 214 ( C ) -Do- Squatting Large 600 Mm X 350 Mm 215 ( D ) White Glazed Vitreous Earthen Ware Urinal Standing Corner Size 600 Mm X 350 Mm Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 216 ( E ) Partition Plate For Urinal 25 X 13 Size 217 ( F ) 5 Liters C.I. Automatic Cistern With All P.V.C Fittings 218 M942white Glazed Vitreous Wash Hand Basin 550 Mm X 400Mm Size Of Hindustan / Parryware / Cera / Naycer Or Any Otherequivalent Make 219 M943white Glazed Vitreous Earthen Ware Kitchensinks Of Hindustan / Parryware / Cera / Nayceror Any Other Equivalent Make 220 ( A ) Kitchen Sink 600 Mm X 450 Mm X 200 Mm ( 24 X 18 X 8 ) 221 ( B ) Kitchen Sink 600 Mm X 450 Mm X 250 Mm ( 24 X 18 X 10 ) 222 ( C ) Lab Sink 450 Mm X 300 Mm X 150 Mm ( 18 X 12 X 6 ) 223 ( D ) Lab Sink 300 Mm X 250 Mm X 150 Mm ( 12 X 10 X 6 ) 224 M944drain Board 225 ( A ) 600 Mm X 450 Mm ( 24 X 18 ) 226 ( B ) 525 Mm X 450 Mm ( 21 X 18 ) 227 M945h.C.I. Pipes 228 ( A ) 50 Mm Dia Single Socket 6-0 ( With Ear Weight 13 Kg ) 229 ( B ) 80 Mm Dia Single Socket 6-0 ( With Ear Weight 18 Kg ) 230 ( C ) 100 Mm Dia Single Socket 6-0 ( With Ear Weight 23 Kg ) 231 ( D ) 150 Mm Dia Single Socket 6-0 ( With Ear Weight 30 Kg ) 232 ( E ) 50 Mm Dia Double Socket 6-0 ( With Ear Weight 14 Kg ) 233 ( F ) 80 Mm Dia Double Socket 6-0 ( With Ear Weight 19 Kg ) 234 ( G ) 100 Mm Dia Double Socket 6-0 ( With Ear Weight 25 Kg ) 235 ( H ) 150 Mm Dia Double Socket 6-0 ( With Ear Weight 13 Kg ) 236 ( I ) 50 Mm Dia Single Socket 3-0 ( With Ear Weight 7.25 Kg ) 237 ( J ) 80 Mm Dia Single Socket 3-0 ( With Ear Weight 10.5 Kg ) 238 ( K ) 100 Mm Dia Single Socket 3-0 ( With Ear Weight 13.75 Kg ) 239 ( L ) 150 Mm Dia Single Socket 3-0 With Ear 240 ( M ) 50 Mm Dia Single Socket 2-0 ( With Ear Weight 5.35 Kg ) 241 ( N ) 80 Mm Dia Single Socket2-0 ( With Ear Weight 8.00 Kg ) 242 ( O ) 100 Mm Dia Single Socket 2-0 ( With Ear Weight 10.10 Kg ) 243 ( P ) 150 Mm Dia Single Socket 2-0 With Ear 244 ( Q ) 50 Mm Dia Single Socket 1-0 ( With Ear Weight 3.4 Kg ) 245 ( R ) 80 Mm Dia Single Socket 1-0 ( With Ear Weight 5.50 Kg ) 246 ( S ) 100 Mm Dia Single Socket 1-0 ( With Ear Weight 7.60 Kg ) 247 ( T ) 150 Mm Dia Single Socket 248 M946h.C.I. Fittings. 249 ( I ) Plain Bend Of Following Size 250 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.75 Kg ) 251 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.5 Kg ) 252 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 253 ( D ) 150 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 254 ( Ii ) Bend With Door With Following Size 255 ( A ) 50 Mm Dia ( Wight Without Ear And Socket 2.75 Kg ) 256 ( B ) 80 Mm Dia ( Wight Without Ear And Socket 4.00 Kg ) 257 ( C ) 100 Mm Dia -Do- 5.5 Kg 258 ( D ) 150 Mm Dia -Do- 259 ( Iii ) Single Junction With Door Of Followings Sizes. 260 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 3.75 Kg ) 261 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 6.50 Kg ) 262 ( C ) 100 Mm Dia -Do- 9.50 Kg 263 ( D ) 150 Mm Dia -Do- 264 ( Iv ) Double Junction With Door Of Following Sizes. 265 ( A ) 50 Mm Dia -Do- 4.5 Kg 266 ( B ) 80 Mm Dia -Do- 7.00 Kg 267 ( C ) 100 Mm Dia -Do- 13.00 Kg 268 ( D ) 150 Mm Dia -Do- 269 ( V ) Heel Rest Bend Of Following Sizes 270 ( A ) 50 Mm Dia 271 ( B ) 80 Mm Dia 272 ( C ) 100 Mm Dia 273 ( D ) 150 Mm Dia 274 ( Vi ) Cowel Of Following Sizes 275 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.25 Kg ) 276 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 277 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 278 ( D ) 150 Mm Dia -Do- 279 ( Vii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.5 Kg 280 ( Viii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.8 Kg 281 ( Ix ) 100 Mm X 80 Mm Floor Trap ( Weight Without Ear And Socket ) 4.00 Kg 282 ( X ) Pass Over 50 Mm X 150 Mm For 50 Mm Projection 283 ( Xi ) -Do- 100 Mm X 150 Mm For 100 Mm Projection 284 ( Xii ) Inverted Junction Single 100 Mm X 50 ( Weight Without Ear And Socket ) 9.0 Kg 285 ( Xiii ) Inverted Junction Double 100 Mm X 50 Mm X 50 Mm ( Weight Without Ear And Socket ) 12.0 Kg 286 ( Xiv ) H.C.I. Offset 80 Mm Projection Of The Following Size 287 ( A ) 50 Mm Dia ( Weight Without Ear And Socket ) 2.75 Kg 288 ( B ) 80 Mm Dia -Do- 3.50 Kg 289 ( C ) 100 Mm Dia -Do- 5.00 Kg 290 ( D ) 150 Mm Dia -Do- 291 ( Xv ) H.C.I. Socket Of Following Sizes 292 ( A ) 50 Mm Dia ( Weight Without Ear ) 1.50 Kg 293 ( B ) 80 Mm Dia ( Weight Without Ear ) 3.00 Kg 294 ( C ) 100 Mm Dia ( Weight Without Ear ) 4.50 Kg 295 ( D ) 150 Mm Dia ( Weight Without Ear ) -Do- 296 M947c.I. Cover With Frame For Manhole And Inspection Chamber 297 ( A ) 600 Mm X 450 Mm Size ( Wt. 39 Kg ) 298 ( B ) 600 Mm X 450 Mm Size ( Wt. 25 Kg ) 299 ( C ) 500 Mm X 450 Mm Size ( Wt. 25 Kg ) 300 M948c.I. Bracket Pair For W.H.B 301 ( A ) 550 Mm X 400 Mm Size ( 22 X 16 ) 302 ( B ) -Do- For 12.5 Liter Cistern 303 ( C ) -Do- For 600 Mm X 450 Mm ( 24 X 18 ) Sink 304 ( D ) 40 Mm X 60 Mm Ms Plate Bracket For Sink As Above 305 M949 ( A ) 32 Mm ( 1 1 / 4 ) C.P. Brass Waste For W.H.B 306 ( B ) 40 Mm ( 1 1 / 2 ) C.P. Brass Waste For W.H.B For Sink 307 ( C ) 32 Mm ( 1 1 / 4 ) C.P. Waste Of White Metal 308 ( D ) 40 Mm ( 1 1 / 2 ) C.P. Waste Of White Metal 309 M950 ( A ) 32 Mm ( 1 1 / 4 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) Withbrass Union For W H B 310 ( B ) 40 Mm ( 1 1 / 2 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) With Brass Union For W H B 311 M95132 Mm ( 1 1 / 4 ) P.V.C. Telescopic Flush Pipe With Brass Union For High Level Cistern 312 M952rubber Inserttion 3 Mm ( 1 / 8 ) Thick 313 M953pig Lead 314 M954yarn 315 M955rubber Gasket For D.I Pipe Of Good Quality 316 ( A ) 80 Mm 317 ( B ) 100 Mm 318 ( C ) 125 Mm 319 ( D ) 150 Mm 320 ( E ) 200 Mm 321 ( F ) 250 Mm 322 ( G ) 300 Mm 323 ( H ) 350 Mm 324 ( I ) 400 Mm 325 ( J ) 450 Mm 326 ( K ) 500 Mm 327 ( L ) 600 Mm 328 ( M ) 700 Mm 329 ( N ) 750 Mm 330 ( O ) 800 Mm 331 ( P ) 900 Mm 332 ( Q ) 1000 Mm 333 ( R ) 1200 Mm 334 M956cotton Waste 335 M957asbestos Suta ( Gland Packing ) 336 M958solvent Cement 337 M959hydrocloric Acid ( Sepecific Gravity 1.20 ) 338 M960cp & Pvc Fitting 339 ( I ) 32 Mm Dia C.P. Waste 340 ( Ii ) 32 Mm Dia Pv C Waste Pipe 750 Mm Long With Coupling 341 ( Iii ) 40 Mm Dia C.P. Waste 342 ( Iv 40 Mm Dia Pvc Waste Pipe 750 Mm Long With Coupling 343 ( V 100 Mm Dia Steel Jali 344 ( Vi ) 15 Mm Dia C.P. Nipple With Coupling ( Short Pieces ) 345 ( Vii ) 50 Mm Dia Pvc Pipe With Coupling 346 M961special Type Of C.P. Bath Room Fittings For V.I.P.Buildings ( Jal, Jaquar, Marc Or Equivalent Mark ) 347 ( I ) Pillar Cock ( Isi ) 348 ( Ii ) Pillar Cock ( Long Neck ) 349 ( Iii ) Bib Cock ( Isi ) 350 ( Iv ) Bib Cock ( Long Thread ) 351 ( V ) Angular Stop Cock 352 ( Vi ) Angular Stop Cock ( Long Thread ) 353 ( Vii ) Concealed Stop Cock Reduce ( Isi ) 354 ( Viii ) Concealed Stop Cock Heavy-Duty Extra Adjustable Wall Flange 355 ( Ix ) Long Body Bib Cock 356 ( X ) Swan Neck Tap With Left Hand Operating Knob 357 ( Xi ) Central Hole Basin Mixer ( Best Quality ) 358 ( Xii ) Wall Mixer With Telephonic Shower Arrangement 359 ( Xiii ) Wall Mixer With Provision For Over Head Shower With Elbow Coupling And Well Flange 360 ( Xiv ) Wall Mixer 3 In 1 System With Provision For Over Head Shower With Elbow Coupling And Wall Flange 361 ( Xv ) Sink Mixer With Swinging Casted Spout 362 ( Xvi ) Sink Cock With Swinging Casted Spout 363 ( Xvii ) 4 - Way Diverter For Concealed Fittings 364 ( Xviii ) Pressure Adjustable Shower With Revolving Joint 365 ( Xix ) Telephone Shower With Flexible Pipe 366 ( Xx ) Flush Cock With Wall Flange ( 25 Mm ) 367 ( Xxi ) Towel Rail 24 368 ( Xxii ) Towel Ring 369 ( Xxiii ) Soap Dish 370 ( Xxiv ) Tumbler Holder 371 ( Xxv ) Toilet Paper Holder 372 ( Xxvi ) Glass Shelf 22 373 ( Xxvii ) Corner Glass Shelf With Bracket 374 ( Xxviii ) Flush Valve Complete With 32 Mm Size Controlcock & Flange 375 M962c.I Special & Pvc Pipes 376 1. C.I Double Shocketted Fittings Bend Such As Bend, Tee, Taper, 377 ( A ) 80-200 Mm 378 ( B ) 250-700 Mm 379 ( C ) 700-1000 Mm 380 2. C.I Double Flange Fittings Such As Tee, Taper, Tailpiece, Bend Etc 381 ( A ) 80-200 Mm 382 ( B ) 250-700 Mm 383 ( C ) 700-1000 Mm 384 Spare Parts Of Hand Pump 385 M963hexagonal Bolt M12x1.75X40mm Long Common To Marks Ii & Iii 386 M964hexagonal Nut M12x1.75Mm 387 M965washer M12 ( 2.5Mm Thick ) 388 M966high Tensile Bolt M10x1.5X40mm Long. 389 M967nyloc Nut M10x1.5Mm 390 M968handle Axle ( Stainless Steel ) 391 M969washer For Handle Axle ( 4Mm Thick ) 392 M970ball Bearing 6204 Z 393 M971spacer For Handle. 394 M972chain With Coupling. 395 M973hexagonal Bolt For Front Cover M12x1.75Mm Long. 396 M974nitrile Rubber Cup Washer For Mark – Ii & Iii 397 M975nitrile Sealing Ring Mark – Ii 398 M976nitrile Rubber Seating Big For Lower Valve Mark-Ii 399 M977nitrile Rubber Seating Small For Upper Valve Mark-Ii. 400 M978hexagonal Rod Coupling M12x1.75X50mm Long. 401 M979pump Head Assembly ( G.I. ) With Front Cover, Bolt & Third Plate. 402 M980front Cover ( G.I. ) 403 M981handle Assembly ( G.I. ) 404 M982 ( A ) Water Tank Assemblyfor Mark – Ii ( G.I. ) 405 ( B ) Water Tank Assembly For Mark – Iii ( Vlom-65 ) 406 M983stand Assembly ( G.I. ) Normal. 407 M984stand Assembly ( Telescopic ) ( G.I ) . 408 M985connecting Rod 3Mtr. Long With Coupling And Nut ( Electrogalvanized ) 409 M986a ) Cylinder Assembly Complete Set For Mark-Ii 410 B ) Cylinder Assembly Complete Set For Mark-Iii ( Vlom-65 ) 411 M987a ) Upper Valve Assembly Complete Set For India Mark-Ii 412 B ) Upper Valve Assembly Complete Set For India Mark-Iii ( Vlom-65 ) 413 M988a ) Lower Valve Assembly Complete Set For India Mark-Ii 414 B ) Lower Valve Assembly Complete Set For Im-Iii 415 M989reducer Cap For Cylinder Mark-Ii 416 M990a ) Plunger Rod ( S.S. ) For Mark – Ii 417 B ) Plunger Rod ( S.S. ) For Mark – Iii 418 M991upper Valve Guide ( G.M. ) . 419 M992rubber Seat Retainer For Mark-Ii 420 M993third Plate For Head Assembly ( Galanized ) 421 M994cylinder Body With Brass Liner For Im-Ii With Reducer Cap For Top And Bottom. 422 M995gun Metal Spacer. 423 M996check Valve Guide Mark-Ii 424 M997a ) Check Valve Seat For Mark – Ii 425 B ) Check Valve Seat For Mark – Iii 426 M998nitrile Rubber “O” Ring ( Vlom-65 ) 427 M999push Rod For Mark – Iii ( S.S ) . 428 M1000check Nut For Push Rod ( S.S. ) . 429 M1001nitrile Rubber Cup Washer For Vlom-50 430 M1002nitrile Rubber Sealing Ring For Mark – Iii Vlom-65 431 M1003nitrile Rubber Seating Big For Lower Valve Mk-Ii 432 M1004nitrile Rubber Seating Big For Lower Valve M-Iii Vlom-65 ) 433 M1005nitrile Rubber Bobbin Vlom-50 434 M1006nitrile Rubber “O” Ring Vlom-50 435 M1007nitrile Rubber Cone For Vlom-50 436 M1008nitrile Rubber Cone For Vlom-65 437 M1009nitrile Rubber Centralizer 150Mm For ( Vlom-65 ) . 438 M1010nitrile Rubber Centralizer 125Mm For ( Vlom-65 ) . 439 M1011nitrile Rubber Centralizer 150Mm For ( Vlom-50 ) . 440 M1012nitrile Rubber Centralizer 125Mm For Vlom-50 441 M1013nitrile Rubber Centralizer 100Mm For Vlom-50 442 M1014water Tank Assembly Mark – Iii Vlom-50 443 M1015cylinder Assembly Complete Set For Mark – Iii ( Vlom-50 ) 444 M1016upper Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 445 M1017lower Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 446 M1018a ) Upper Cap Cylinder Mark – Iii ( Vlom-65 ) 447 B ) Upper Cap Cylinder Mark – Iii ( Vlom-50 ) 448 M1019a ) Bottom Cap For Mark – Iii ( Vlom-50 ) 449 B ) Bottom Capfor Mark – Iii ( Vlom-65 ) 450 M1020follower For Im-Iii 451 M1021cage For Mark-Iii 452 M1022s.S. Hexagonal Bolt M-6X25mm Long. 453 M1023basic Rate Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-2, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Ecommended For Use With Cylinder Assembly Suitable For Bore Well Dia 100 To 125Mm Casing Pipe. 454 M1024basic Rate Of Upvc Pipe 125Mm Dia Conforming To I.S.I. Latest Revision Is 12818 / 2016 Cml No. 5543459 455 M1025basic Rate Of 32Mm G.I. Pipe In 3 Mtrs. Length ( Medium ) With Seamless Socket As Per Relevent B.I.S. Specificationis 1239 ( Part-I ) / 2004 456 M1030rcc Esr 457 Designing ( Aesthetically ) , And Constructing Rcc Elevated Service Reservoirs Of Following Capacity With Rcc Staging Consisting Of Columns, Internal And External Bracings Spaced Vertically Not More Than 4.5 Metres Centre To Centre For Esr Having Capacity Upto 500 Cum And Not More Than 6M C / C For Esr Having Capacity Above 500 Cum Including Excavation In All Types Of Strata, Foundation Concrete, Cement Plaster With Water Proofing Compound To The In Side And Out Side Face Of The Container And Also Plaster With Plastic Paint In All Columns And Bracingsincluding Refilling Disposing Off The Surplus Stuff With In A Lead Of 50 Metres, All Labour And Material Charges Including Lowering, Laying, Erecting, Hoisting And Jointing Of Pipe Assembly Of Inlet, Outlet, Washout, Overflow And Bypass Arrangements As Per Departmental Design, Providing And Fixing Accessories Such As M.S. Ladder Out Side, Stainless Steel Lader In Contenor, C.I. Manhole Frame And Covers, Water Level Indicators, Lightening Conductor, G.I. Pipe Railing Around Walk Way And Top Slab, Providing Stair Case From Ground Level To Roof Level, M.S. Grill Gate Of 2M Height With Locking Arrangement Of Approved Design, B.B. Masonry Chambers For All Valves, Ventilating Shafts, Providing And Applying Three Coats Of Acrylie Emulsion With Silicon Edditives Paint To The Structure Incluingroof Slab, Epoxy Painting To Internal Surface And Anti-Termite Treatment For Under Ground Part Soft He Structure And Giving Satisfactory Water Tightness Test As Per I.S. Code. The Job To Include Painting Then Ame Of The Scheme And Other Details On Thereservoir As Per The Directions Of Engineer In - Charge. 458 Notes 459 The Design Of The Structure Be In Accordance With Relevant I.S. Specification ( I.S. 3370 - 1965 Or Revised. ) 460 The Design Shall Satisfy The Stipulations As Per I.S. 1893 -1984 And I.S.13920 / 1993 For Seismic Force And I.S.-11682 / 1985 For R.C.C. Staging Of Over Head Tanks. 461 For Design Having More Than 6 Columns, Suitable Bracing Is Obligatory. 462 Plain Round Mild Steel Bars Grade- I Conforming To I.S.432 Part-I Orhigh Yield Strength Deformed Bars Conforming To I.S. 1786 Or I.S. 1139 Shall Beused, Grade- I Imildsteel Bars Will Not Be Allowed 463 Irrespective Of The Type Of Foundation Proposed In The Design, One Set Of Bracing Be Provided At The Ground Level. 464 These Rates Include Providing M.S. Ladder For E.S.R.S Upto 2 Lakh Litres Capacity And Providing Spiral Stair Case For E.S.R. Above 2 Lakh Litres Capacity. 465 Staging Shall Have To Bede Signed With Stresses Of M-200 Concrete For Esr. However All Rcc Construction Should Be Donein M-250. Structures In Contact With Water Shall Be Designed & Casted In M-300 466 These Rates Are Including The Cost Of Up Lift Pressure If Any And Entire Dewatering During Execution. Incase Of Water Logging Are A Where Water Is Struck At Shallow Depth, Extra Provision Of Dewatering Shall Be Made As Per Site Condition. 467 All Conditions Given In The Member SecretaryS Circular No. Mjp / Ts-I / 350 / 1668 Dt. 2-8-97 And Mjp / S-I / 350 / 2127 Dt. 13-7-99 Shall Be Strictly Followed And Additional Cost, If Any, Due To These Conditions Is Included In The Rates Mentioned Below. 468 75 % Part Rate Shall Be Payable For Reinforcement Concrete And Plastering Items Of Containers Of E.S.R. Till Satisfactory Hydraulic Testing For Water Tightness Is Given; And Till That Work Shall Be Treated As Incomplete. 469 The Rates Indicated In The Table Are Excluding The Cost Of Pipes, Specials And Valves Required For Inlet, Outlet, Washout, Overflow And Bypass Arrangement. The Scope Of Work, However, Includes Cost Of Erecting, Laying And Jointing Of Pipe And Valves Including Cost Of Jointing Materials Upto 5 M Beyond Outer Face Of Outer Most Column ( Cost Of Pipe, Specials And Valves Is Taken As 10% Of The Cost Of Esr As Per Table ) . 470 For Esr Upto 500 Cum Capacity C.I. Double Flanged Pipes Upto 300 Mm Dia Shall Be Provided And C.I. Specials Shall Be Used. For Esr Above 500 Cum Capacity C.I. / M.S. Pipe Assembly With Minimum 8 Mm Thickness Upto 500 Mm Dia And Minimum 10 Mm Thickness Above 500 Mm Dia Can Be Used With Proper Anti-Corrosive Epoxy Treatment From In Side And Out Side. 471 Below Mentioned Rates Are For Foundation Swith Individual Footing With Bearing Capacity Of 20 Tonnes Per Square Metre. For Raft Foundations, These Rates Shall Be Increased By 7.5% Where Safe Bearing Capacity ( Sbc ) Is 5 Mt Per Sqm And By 5 % Where Sbc Is More Than 5Mt / Sqm And Upto 10 Mt / Sqm. This % Of5 % Or 7. 5 % Is Applicable For Estimation Of Amount Of Lumpsum Item Of Esr. For Extra Item Due To Change From Individual Foundation To Raft, Actual Increase In Concrete And Steel Be Paid As Per Relevant Dsr Item. 472 The Rate Shall Be Increased By 30 % For Bearing Piles Upto Depth Of 10 M And For Further Increased In Depth By 5 M Each, It Shall Be Increased By Another 10%. These Rates Are Applicable Where Raft Is Not Feasible. For Pile Foundations Sulphate Resistant Cement Shall Only Beused. Single Pile For The Column Is Not Permitted, Group Of Piles Shall Be Designed With Pile Cap For Each Column Of Esr. 473 The Rates Are Applicable For Staging Height Of 12 M. These Rates Shall Be Increased Or Decreased For Per Metre Variation In This Staging Height As Below : 474 12 To 16 M Staging - 2% Per Metre 475 16 To 20 M Staging - 3% Per Metre 476 20 M And Above - 4% Per Metre 477 For 17 M Staging Height, Percentage Calculation Will Be Like Below : 478 12 To 16 M --- 4 X 2 = 8% 479 16 & 17 M --- 1 X 3% = 3% Total = 11% 480 For 21 M Staging Height, Percentage Calculation Will Be Like Below : 481 12 To 16 M --- 4 X 2 = 8% 482 16 To 20 M --- 4 X 3% = 12% 483 20& 21 M --- 1 X 4% = 4% Total = 24% 484 Following Rates Are For Seismic Zone Iii. For Zone Iv, These Rates Shall Be Increased By 5% And For Zone Ii, These Rates Shall Be Decreased By 5%. Concerned Executive Engineer Shall Confirm The Seismic Zone For The Scheme From Seismic Zone Splan Before Estimation And Adopt Appropriate Rates As Per Actual Seismic Zones. ( Seismic Maps Attached In This Csr ) . 485 Notes 486 Conditions From Sr.No.1 To 10 Shall Form A Part And Parcel Of The Tender And Must Be Included In The Draft Tender Papers For Works Of R.C.C. E.S.R. 487 Conditions From Sr.No.11 To 16 Are For Estimation Purpose Only And Shall Not Appear In The Tender. 488 Rates For Rcc Esrs 489 Upto 25, 000 Litres 490 Cost Of 25, 000 Litres Capacity 491 Add For Capacity Above 25, 000 Upto 50, 000 Litres 492 Cost Of 50, 000 Litres Capacity 493 Add For Capacity Above 50, 000 Upto 75, 000 Litres 494 Cost Of 75, 000 Litres Capacity 495 Add For Capacity Above 75, 000 Upto 1, 00, 000 Litres 496 Cost Of 1, 00, 000 Litres Capacity 497 Add For Capacity Above 1, 00, 000 Upto 1, 50, 000 Litres 498 Cost Of 1, 50, 000 Litres Capacity 499 Add For Capacity Above 1, 50, 000 Upto 2, 00, 000 Litres 500 Cost Of 2, 00, 000 Litres Capacity 501 Add For Capacity Above 2, 00, 000 Upto 2, 50, 000 Litres 502 Cost Of 2, 50, 000 Litres Capacity 503 Add For Capacity Above 2, 50, 000 Upto 3, 00, 000 Litres 504 Cost Of 3, 00, 000 Litres Capacity 505 Add For Capacity Above 3, 00, 000 Upto 4, 00, 000 Litres 506 Cost Of 4, 00, 000 Litres Capacity 507 Add For Capacity Above 4, 00, 000 Upto 5, 00, 000 Litres 508 Cost Of 5, 00, 000 Litres Capacity 509 Add For Capacity Above 5, 00, 000 Upto 7, 50, 000 Litres 510 Cost Of 7, 50, 000 Litres Capacity 511 Add For Capacity Above 7, 50, 000 Upto 10, 00, 000 Litres 512 Cost Of 10, 00, 000 Litres Capacity 513 Add For Capacity Above 10, 00, 000 Upto 15, 00, 000 Litres 514 Cost Of 15, 00, 000 Litres Capacity 515 Add For Capacity Above 15, 00, 000 Upto 20, 00, 000 Litres 516 Cost Of 20, 00, 000 Litres Capacity 517 M1031rcc Gsr And Sump 518 Designing ( Aesthetically ) , And Constructing Rcc Ground Service Reservoirs / Rcc Sumps In M-300 Mix. Of Required Capacity Including Excavation In All Types Of Strata, Foundation Concrete, Container Walls, Bottom Slab Top Rcc Roof Slab / Or Dome, 20 Mm Thick Cement Plaster With Water Proofing Compound In Cm 1:3 Proportion. To Inside Face Of The Container, Including Epoxy Paint From Inside Including Refilling And Disposing Of Surplus Stuff Within Lead Of 50 M, All Labour And Material Charges, For Laying And Jointing Of Pipe Assembly For Inlet, Outlet Washout, Over Flow And Bye-Pass Arrangement Consisting Of C.I. / M.S. D / F. Pipes, Specials And Valves Of Given Diameters, Providing And Fixing Accessories Such As M.S. Ladder Inside And Outside, C.I. Manhole Frame And Cover, Water Top Slab, B.B. Masonry Chamber For All Valves, Ventilating Shafts, Including Giving Satisfactory Hydraulic Test And Water Tightness Test As Per Is Code And Providing Three Coat Of Cement Paints To All Expose Surface Of Structure Including Roof Surface Etc. Complete As Per Design Data, Criteria, Obligatory Requirements And Detailed Specifications. 519 Anti –Termite Treatment Shall Be Given For Under Ground Portion Of The Structure. 520 Notes 521 The Design Shall Be In Accordance With Various Relevant I.S. Specification ( I.S.456 / 2000, I.S.875-1987, I.S.3370-1965 Or Revised. ) 522 Only M.S. Bars Grade I Conforming To I.S. 432 Part-I Or High Yield Strength Deformed Bars Conforming To I.S. 1786 Or I.S.1139 Shall Be Used.Grade- Ii M.S. Bars Shall Not Be Used. 523 Entire Structure Shall Be In M-300 Only. 524 The Scope Of Pipe Assembly Work Shall Be Upto 5 Metre Beyond Out Side Face Of The Wall, Cost Of Pipes Valves And Specials Is Not Included In The Rate But Labour Cost For Laying And Jointing Is Included. 525 The G.S.R. / Sump Above 15 Lakh Litres Capacity Shall Be In Two Compartment. 526 The Job Includes Designing The Structure For Up Lift Pressure And Dewatering If Required During Entire Execution And Disposal Of Surplus Excavated Stuff Within Lead Of 50 Metres As Directed By Engineer-In-Charge. If Up Lifts Considered In Design, Then These Rates Shall Be Increased By 7.5%. 527 G.S.R. Outlets Shall Be With Bell Mouth Of Approved Pattern In Bottom Slab And Cost Of Designing Bell Mouth Is Included In The Rate. Sump Well Includes Cost Of Suction Pit Required At Bottom. 528 For Pipe Diameters Upto 300Mm Only Cipipes And Ci Specials Shall Be Used. For Pipe Diameters Above 300Mm, M.S. Pipes And Specials Minimum 10Mm Thick Shall Be Used With Proper Anti Corrosive Epoxy Treatment From Inside And Outside. 529 Cost Of Pump House Is Not Included In These Rates. 530 Above Rates Are Applicable For Seismic Zones 2, 3 And 4. 531 75% Part Rate Shall Be Payable For Reinforcement, Concrete And Plastering Items Of All Types Of G.S.R. Sand Sump Still Satisfactory Hydraulic Testing For Water Tightness Test Is Given And Till That Work Shall Be Treated As Incomplete. 532 10% Shall Be Added For Sump If Over Head Pump House Is Proposed. 533 Note: Conditions From Sr.No.1 To 11 Shall Form A Part And Parcel Of Tender And Must Be Included In The Draft Tender Papers For Work Of R.C.C .Gsrs And Sumps. 534 Rates For Rcc Gsrs And Sumps 535 Upto 25, 000 Litres 536 Cost Of 25, 000 Litres Capacity 537 Add For Capacity Above 25, 000 Upto 50, 000 Litres 538 Cost Of 50, 000 Litres Capacity 539 Add For Capacity Above 50, 000 Upto 75, 000 Litres 540 Cost Of 75, 000 Litres Capacity 541 Add For Capacity Above 75, 000 Upto 1, 00, 000 Litres 542 Cost Of 1, 00, 000 Litres Capacity 543 Add For Capacity Above 1, 00, 000 Upto 1, 50, 000 Litres 544 Cost Of 1, 50, 000 Litres Capacity 545 Add For Capacity Above 1, 50, 000 Upto 2, 00, 000 Litres 546 Cost Of 2, 00, 000 Litres Capacity 547 Add For Capacity Above 2, 00, 000 Upto 3, 00, 000 Litres 548 Cost Of 3, 00, 000 Litres Capacity 549 Add For Capacity Above 3, 00, 000 Upto 5, 00, 000 Litres 550 Cost Of 5, 00, 000 Litres Capacity 551 Add For Capacity Above 5, 00, 000 Upto 10, 00, 000 Litres 552 Cost Of 10, 00, 000 Litres Capacity 553 Addforcapacityabove10, 00, 000Upto15, 00, 000 Litres 554 Cost Of 15, 00, 000 Litres Capacity 555 Add For Capacity Above 15, 00, 000 Litres 556 Note: 10% Shall Be Added Over The Cost Of Gsr For Sump Where Over Head Pump House Is Proposed. 557 M1032unconventionalwater Treatment Plant 558 Designing ( Aesthetically ) , Providing And Constructinghigh Rate Unconventionalwatertreatmentplant I.E. Simplified Water Treatment Plant Consisting Of Civil Works Includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti-Termitetreatmenttoentirestructurebelowgroundlevel, Ceramic Tiles For Floring, Acrylic Emulsion With Silicon Additives Paint From Outside Stainless Steel Railing, Mechanicalandelectricalcomponentsofvarioussub-Worksasgivenbelow : Includingnecessaryhydraulic Testing, Structuraltesting And Trial For 3 Months, Etc. Completeas Directedbyengineer-In-Charge ( Turn-Key Job ) Works. 559 Aeration Fountain 560 Inlet Arrangements 561 Mixing Channel With Ventury Flume And Flow Measuring Arrangement 562 Inlet Channel 563 Flocculator- Conforming To I.S. 7208-1974 ( Type-C ) With Detention Period Of 30 Minutes 564 Tube Settlers-Designing, Fabricating And Constructing Tube Settlers With Square Or Any Other Shaped Tube Like Circular, Cheveron, Hexagonal Etc .Having Proven Performance 565 Rapid Sand Gravity Filters - All Valve Shall Be Glandless. 566 Filter House 567 Chemical House 568 Alum Tanks- 2Nos. With Mixing, Carrying And Dosing Arrangements With Piping. 569 100 Kg Chlorine Cylender For Capacity Upto 5Mld And Chlorine Tonner For Capacity Above 5 Mld. 570 Tcl Solution Tank With Mixing, Carrying And Dosing Arrangement With Piping. 571 Bypass Arrangement 572 External And Internal Electrification 573 Laboratory Equipments 574 Wash Water Tanks Of Capacity Equal To12 Minutes To Wash Specified Number Of Filter Beds At Time At 600 Lit / M2 / M Under Head Of 12M At Under Drain. 575 Wash Water Pumps With 100% Standby 576 Air Blowers Capable Of Delivering 600 Lmp Per Square Metre Of Free Air Of Filter Area At 0.4 Kg / Sqcm At The Under Drains ( 100 % Standby ) .Air Blowers Shall Be Adopted For Wtp Having Capacity More Than 3 Mld Only. Below 3 Mld Capacity, Air Blowers Shall Not Be Adopted. 577 Pure Water Sump Of Capacity Equal To 1 Hourpumping Capacity. 578 Pure Water Pump House Over The Sump / By The Side Of Sump. 579 Drainage Arrangements 580 Alum Store 581 Sanitary Block With Necessary Water Supply And Drainage Arrangements And Internalwbm Roads. 582 These Rates Are Applicable For Seismic Zones 2, 3 And 4. 583 Rates Given Below Are Inclusive Of Uplift Pressure If Any And Dewatering During The Entire Work. 584 All Rcc Structures Shall Be Constructed In M-250. Structures In Contact With Water Shall Be In M-300. 585 Unconventional Treatment Plants Less Than 1 Mld Capacity Shall Not Be Constructed. 586 All The Structural Steel Works / Fabrications Are To Be Provided With Application Of Hot Dip Zinc Coating According To Specification As Per Is 4759:1996 ( Reafirmed 2006 ) . 587 Note: Conditions From Sr. No. 1 To 28 Shall Form A Part And Parcel Of The Tender And Must Be Included In Draft Tender Papers For The Work Of Unconventional Treatment Plants. 588 Unconventional Water Treatment Plant 589 Fixed Cost For 1 Mld 590 Add For Capacity Above 1 Mld Upto 2 Mld 591 Cost Of 2 Mld Treatment Plant 592 Add For Capacity Above 2 Mld Upto 3 Mld 593 Cost Of 3 Mld Treatment Plant 594 M1033conventionalwater Treatment Plant 595 Designing ( Aesthetically ) , Providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, Mechanicalandelectricalworks Includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, Mechanicalandelectricalcomponentsofvarioussub-Worksasgivenbelow, Includingnecessaryhydraulic Testing, Structuraltesting, Equipmenttestingandtrialrunfora Periodof3 Months, Etc. Completeas Directedbyengineer-In-Charge ( Turn-Key Job ) . 596 Aeration Fountain- Plan Are A Not Less Than 0.625 Square Metre Per Mld 597 Ventury Flume - With Necessary Devices, Consisting Of Simple Mechanical Indicator. ( Pedestal Type Gauge ) 598 Flash Mixer-Rapid Mixing Device, Detention Time 60 Seconds To Give Velocity Gradient 300 To 400 Sec -1, Vane Mixer Type Conforming To I.S. 7090 Of 1985. 599 Flocculator – Conforming To I.S.7208-1974 ( Type-C ) With Detention Period Of 30 Minutes. 600 Clarifier - Horizontal Flow Circular Tank, Detention Period 2-5 Hours, Overflow Rate 30 Cubic Metre Per Square Metre Per Day ( To Be Specified ) , Weir Loading Not More Than 300 Cubic Metre Per Metre Per Day, With Mechanical Sludge Scraper Conforming To I.S. No. 10313-1982. 601 Rapid Sand Filter Sand Filter House-Filter Designed For Filteration Rate Of 5, 000 Litres Per Square Metre Per Hour, Minimum 2 Beds For Plant Upto 10 Mld, For Larger Plants As Specified, Filters To Be Located In Filter House With Roof Slab, Pipe Gallery And Platform Minimum 5.5 Metre In Width. 602 Filtersand-Effective Size 0.45 To 0.70Mm, Uniformity Coefficient Not More Than 1.7, Nor Less Than 1.3, Depth Of Water Over Sand 0.75M, Free Board 50Cm, Gravel 0.45M In Depth, Sand And Gravel Conforming To I.S. 8491 ( I ) -77, Back Wash By Air Wash, Stand Ard Appurtenances ( To Be Specified ) , Rate Of Flow Controller, Filter Gauge, Sand Expansion Gauge, Etc. 603 Wash Water Tank-Capacity To Be Specified And Suitable To Supply Water To Wash 2 Filter Units At A Time Where The Units Are 4 Or More. 604 Wash Water Pumps- Capacity To Fill Water Tank In 1 Hour With 100% Standby. 605 Air Blowers-Capable Of Delivering 600 Lmp Per Square Metre Of Free Air, Of Filter Area At 0.4Kg / Sqcm At The Under Drains ( 100% Standby ) . 606 Chemical House In Two Storeys 607 Ground Floor To Accommodate 7 Days Alum Requirement And Sundry Storage. 608 First Floor To Accommodate Alum And Lime Tanks.Etc. 609 Solution Tanks-Minimum 3 Tanks ( One For Preparation, Second For Dosing And Third As Standby ) , Each Tank Capable Of Giving 8 Hours Maximum Dose Without Interruption, Minimum Free Board 0.30M, Trays For Dissolving, Level Indicator, Mechanical Agitation Devices, Solution Feed And Drain Lines, Solution Feed Device ( Constant Head Device, Strength Of Solution Upto 10% Only ) Conforming To I.S. 9222 Part-I 1979. 610 Pure Water Sump And Sump House. 611 Capacity Of Sump – One Hour Of Designed Flow. 612 Pump House- Pump House Of Required Size Over The Sump Or By The Side. 613 Store House-Suitable For Alum Storage Of Three Months Requirement In Monsoon With 10% Extra Capacity For Other Sundry Articles. 614 Vacuum Feed Type Chlorinators- Make Tobe Approved By Mjp. 615 Conforming To I.S. 10533 - A Part-Ii 1983 616 Rate For Withdrawal 617 Temperature Kg. Of Chlorine Discharge Degree C Per Day ( Cylinders ) 618 45 67Tonnes 619 10 6.359.50 110 620 15 10.75 16.10130 621 20 14.50 21.24254 622 27&Above18.70 28.12315 623 Chlorinator Equipment And Container Room To Conform To I.S. 10553 Part-I 1983. 624 100% Standby Shall Be Provided. 625 By Pass Arrangements - C.I. Or M.S. Pipes. 626 Disposal Of Waste From Wtp: Safe Disposal Arrangement To Near By Nala Including Cost Of Pipe 627 For Wtp Of Capacity 30 Mld And More Additional Arrangement For Backwash Water Recycle Shall Be Provided, Including Sump, Pupming Machinary, Rising Main Etc Complete 628 Drainage Arrangements – Rcc Pipes Up To Plot Boundary. 629 Electrical Installation – Both Internal And External Including Entire Plant Area. 630 Laboratory Equipment –As Per Requirement ( To Be Specified During Tendering ) . 631 Sanitary Blocks – Carpet Area -15 Square Metre Minimum Upto 25 Mld And 25 Square Metre Above 25 Mld. 632 Administrative Block And Internal Road-To Accommodate Office Room, Chlorine Room, Laboratory Room, Panel Board Room, Blower Room Etc. And Wbm Road To Connect All Units From Main Gate Of Plot. 633 Rates Given Below Are Inclusive Of Up Lift Pressure If Any And Dewatering During Entire Work. 634 All Pipes Condutes Channels With20%Overloading 635 These Rates Are Applicable For Seismic Zones 2, 3 And 4. 636 All Rcc Structures Shall Be Constructed In M-300. 637 Note: Conditions From Sr. No. 1 To 22 Shall Form A Part And Parcel Of The Tender And Must Be Incorporated In Draft Tender Papers Of Conventional Treatment Plants ( Proposed ) . 638 Conventional Water Treatment Plant 639 Above3 Mld To Upto 5 Mld 640 Cost Of 5 Mld Treatment Plant 641 Add For Capacity Above 5Mld Upto 10 Mld 642 Cost Of 10 Mld Treatment Plant 643 Add For Capacity Above 10 Mld Upto20 Mld 644 Cost Of 20 Mld Treatment Plant 645 Add For Capacity Above 20 Mld Upto 50 Mld 646 Cost Of 50 Mld Treatment Plant 647 Add For Capacityabove 50 Mld Upto 100 Mld 648 Cost Of 100 Mld Treatment Plant 649 Add For Capacity Above 100 Mld 650 M1034gpt / Hygpt :Drilling By Rotary Drill Machine Of Size 300Mm & 400Mm Dia With T.C. Drill Bit For Tubewells In All Kinds Of Soil Including Moorum, Hard Soil, Soil Mixed With Pebbles, Shingles, Compacted Soil, Clay, Soft And Decomposed Rock Etc, Up To 60 Meters Depth Including Reaming To Facilitate Smooth Lowering Of Casing Pipe Etc. As Per Specification And Direction Of E / I ( Basic Rates ) 651 300 Mm Dia For Gpt 652 400 Mm Dia For Hygpt 653 M1035hydt : Cost Of Drilling 200 Mm X 165 Mm X 125 Meter Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site ( Basic Rates ) 654 From 0-50 Meter 655 From 51-125 Meter 656 M1037dt :Basic Rates For 125 / 115 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil And Rock For Installation Of Hand Pump With Dth Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant, For Making 125 / 115 Mm Dia Boring Etc. And Cost Of Transporting Rig Machine And Other Vehicle Up To Site Of Work As Per Specification And Dirrection Of Engineer Incharge ( Basic Rates ) 657 Drillig Upto 30 Mtr Depth Below G. L. In Rural Area 658 Drilling Beyond 31 Mtr Upto 60 Mtr Below G. L. In Rural Area 659 M1038trenchless 660 Installation Of Product Pipe By Manual Pipe Jacking Method Including Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Manual Shielded Excation , Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 661 From 900 Mm To 1000 Mm Dia 662 In Soft Soil 663 In Hard Soil 664 In Sandy Soil 665 In Stone Soil 666 From 1000 Mm To 1200 Mm Dia 667 In Soft Soil 668 In Hard Soil 669 In Sandy Soil 670 In Stone Soil 671 Above 1200 Mm To 1500 Mm Dia 672 In Soft Soil 673 In Hard Soil 674 In Sandy Soil 675 In Stone Soil 676 Installation Of Product Pipe By Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 677 Upto 300 Mm Dia 678 In Soft Soil 679 In Hard Soil 680 In Sandy Soil 681 In Stone Soil 682 Above300 Mm To 450 Mm Dia 683 In Soft Soil 684 In Hard Soil 685 In Sandy Soil 686 In Stone Soil 687 Above 450 Mm To 600 Mm Dia 688 In Soft Soil 689 In Hard Soil 690 In Sandy Soil 691 In Stone Soil 692 Above 600 Mm To 900 Mm Dia 693 In Soft Soil 694 In Hard Soil 695 In Sandy Soil 696 In Stone Soil 697 Installation Of Product Pipe By Guided Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 698 Upto 300 Mm Dia 699 In Soft Soil 700 In Hard Soil 701 In Sandy Soil 702 In Stone Soil 703 Above300 Mm To 450 Mm Dia 704 In Soft Soil 705 In Hard Soil 706 In Sandy Soil 707 In Stone Soil 708 Above 450 Mm To 600 Mm Dia 709 In Soft Soil 710 In Hard Soil 711 In Sandy Soil 712 In Stone Soil 713 Above 600 Mm To 900 Mm Dia 714 In Soft Soil 715 In Hard Soil 716 In Sandy Soil 717 In Stone Soil 718 M1039providing And Supplying Isi Mark Ci / D / F Reflux Valves ( Non Return Valves ) Of Following Dia Inspection Charges Unloading From Railway Wagon , Loading Into Truck Transportation Upto Department Stores / Site Unloading Stacking Etc. Complete Reflux Valve As Per Is 5312 Part I ( 1984 ) 719 Without Byepass Arrangement - Pn-1 720 50 Mm 721 65 Mm 722 80 Mm 723 100 Mm 724 125 Mm 725 150 Mm 726 200 Mm 727 250 Mm 728 300 Mm 729 350 Mm 730 400 Mm 731 450 Mm 732 500 Mm 733 600 Mm 734 700 Mm 735 750 Mm 736 800 Mm 737 900 Mm 738 1000 Mm 739 1100 Mm 740 1200 Mm 741 With Byepass Arrangement - Pn-1 742 50 Mm 743 65 Mm 744 80 Mm 745 100 Mm 746 125 Mm 747 150 Mm 748 200 Mm 749 250 Mm 750 300 Mm 751 350 Mm 752 400 Mm 753 450 Mm 754 500 Mm 755 600 Mm 756 700 Mm 757 750 Mm 758 800 Mm 759 900 Mm 760 1000 Mm 761 1100 Mm 762 1200 Mm 763 Without Byepass Arrangement - Pn-1.6 764 50 Mm 765 65 Mm 766 80 Mm 767 100 Mm 768 125 Mm 769 150 Mm 770 200 Mm 771 250 Mm 772 300 Mm 773 350 Mm 774 400 Mm 775 450 Mm 776 500 Mm 777 600 Mm 778 With Byepass Arrangement - Pn-1.6 779 50 Mm 780 65 Mm 781 80 Mm 782 100 Mm 783 125 Mm 784 150 Mm 785 200 Mm 786 250 Mm 787 300 Mm 788 350 Mm 789 400 Mm 790 450 Mm 791 500 Mm 792 600 Mm 793 Providing Double Flange Sluice Valve ( Size 50 Mm To 1200 Mm ) Confirming For Is - 2906 / 14846 Including Worn Gear Arrangements As Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete . 794 With Byepass Arrangement - Pn-1 795 50 Mm 796 65 Mm 797 80 Mm 798 100 Mm 799 125 Mm 800 150 Mm 801 200 Mm 802 250 Mm 803 300 Mm 804 350 Mm 805 400 Mm 806 450 Mm 807 500 Mm 808 600 Mm 809 700Mm 810 750 Mm 811 800 Mm 812 900 Mm 813 1000 Mm 814 1100 Mm 815 1200Mm 816 Without Byepass Arrangement - Pn-1 817 50 Mm 818 65 Mm 819 80 Mm 820 100 Mm 821 125 Mm 822 150 Mm 823 200 Mm 824 250 Mm 825 300 Mm 826 350 Mm 827 400 Mm 828 450 Mm 829 500 Mm 830 600 Mm 831 700Mm 832 750 Mm 833 800 Mm 834 900 Mm 835 1000 Mm 836 1100 Mm 837 1200Mm 838 Providing Double Flange Sluice Valve Confirming For Is - 2906 / 14846 Including Worn Gearas Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete For Rateincluding All Taxes . . 839 Without Byepass Arrangement - Pn-1.6 840 50 Mm 841 65 Mm 842 80 Mm 843 100 Mm 844 125 Mm 845 150 Mm 846 200 Mm 847 250 Mm 848 300 Mm 849 350 Mm 850 400 Mm 851 450 Mm 852 500 Mm 853 600 Mm 854 700Mm 855 750 Mm 856 800 Mm 857 900 Mm 858 1000 Mm 859 1100 Mm 860 1200Mm 861 With Byepass Arrangement - Pn-1.6 862 50 Mm 863 65 Mm 864 80 Mm 865 100 Mm 866 125 Mm 867 150 Mm 868 200 Mm 869 250 Mm 870 300 Mm 871 350 Mm 872 400 Mm 873 450 Mm 874 500 Mm 875 600 Mm 876 M1040design And Supply Of V -Wire Screen Laterals Suitable For Infiltration Galleryas Per Site Condition And Detail Provided End Connection Suitable Flange Excluding Taxes And Transportation . 877 Dia - 06 Inch ( 150 Mm ) 878 Id - 153 Mm Od -167 Mm 879 Screen Thickness - 07 Mm 880 Slot - 1.00 Mm 881 Moc - Lowcarbon Galvenised Steel 882 Length - 5 Mtr. 883 Dia - 08 Inch ( 200 Mm ) 884 Id - 205 Mm Od -221Mm 885 Screen Thickness - 08 Mm 886 Slot - 1.00 Mm 887 Moc - Lowcarbon Galvenised Steel 888 Length - 5 Mtr. 889 Dia - 10 Inch ( 250 Mm ) 890 Id - 256 Mm Od -276Mm 891 Screen Thickness - 10 Mm 892 Slot - 1.00 Mm 893 Moc - Lowcarbon Galvenised Steel 894 Length - 5 Mtr. 895 Dia - 12 Inch ( 300 Mm ) 896 Id - 306 Mm Od -326 Mm 897 Screen Thickness - 10 Mm 898 Slot - 1.00 Mm 899 Moc - Lowcarbon Galvenised Steel 900 Length - 5 Mtr. 901 Dia - 14 Inch ( 350 Mm ) 902 Id - 338 Mm Od -363 Mm 903 Screen Thickness - 12.5 Mm 904 Slot - 1.00 Mm 905 Moc - Lowcarbon Galvenised Steel 906 Length - 5 Mtr. 907 M1041supplying All Materials, Labours, Equipments For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Sides From Falling During The Process Of Drilling All Complete Including Carriage Of Materials To Work Site ( Basic Rate ) . 908 M1042supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Dirction E / I ( Basic Rate ) . 909 M1043supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting The Casing Pipe After Lowering In The Bore Including Carriage Of Materials To Work Site Etc. All Complete As Per Specification & Direction Of E / I ( Basic Rate ) . 910 M1044supplying Labour And Equipments Including 125Mm Dia G.I. Cap And Fitting And Fixing Over The Casing Pipe Of Tube Well Properly And Taking It Out As Per Direction E / I ( The Cap Will Be The Property Of Department ) ( Basic Rate ) . 911 M1045supplying All Materials, Labours, Equipments For Constructing P.C.C. ( 1:2:4 ) Circular Platform Around Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design, Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 912 M1046supplying All Materials, Labours And Equipments For Constructing P.C.C. ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 913 M1047supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly & Connecting Rod ( 12 Pcs ) As Per Is : 15500 Part-2 / 2004 ( Basic Rate ) . 914 M1048supply Of 200Mm Dia X 3.00M Long Upvc Casing Pipe Conferming To Is : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 915 M1049supply Of 200Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 916 M1050supply Of 125Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 917 M1051supplying All Tools, Equipments And Labour And Lowering 32 Mm Dia Medium Quality G.I. Pipe In Drilled Tube Well In 3 Mtrs. Length All Complete As Per Dirction E / I Including Carriage Of Materials ( Basic Rate ) . 918 M1052supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod Complete Job As Per Specification & Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 919 M1053supplying All Materials, Labours And Fixing India Mark Ii Hand Pump With All Accessories All Complete Job As Per Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 920 M1054design, Supply, Installation Testing & Commissioning Of Packaged Water Treatment Plants ( Unconventional Type ) Of Different Capacity With ( 20 Hours Operation ) Comprising Of Lamella Clarifier, Static Mixture Flocculation Tank ( Smet ) , Multi Grade Filter ( Mgf ) With Best Quality Filter Media, Lime / Coagulant / Polymer Dosing System Hypo Chloride Dosing System, Raw Water Feed Pump / Clear Water Transfer Pump ( Either Or ) , Sludge Transfer Cum Recirculation Pump, Filter Feed Pump & Back Wash Pump Including All Fitting Like Valve And Other Special Fittings And Electrical Power Supply To The Different Supplied Units With Mcb Panel Internal Electrification With Lighting Arrangement With Treatment Plant Site With Provision Of Chemical Storage And Water Testing Boratoryfacility Should Be From A Reputed Manufacturer / Authorized Distribution / Authorized Dealer Conforming To Relevant Is Codes And Certified By Iso-9001-2008 & 14001, It Also Include Cost Of Civil Foundation, Including Clarified Water Tank Internal Connecting Pipe Line From Raw Water Inlet To Cwr And Applying Internal Epoxy Paint On The Supply Equipment All The Prices Are Exclusive Of Gst, Allied Structure / Items Which Are Site Specific Such As External Electrification, Approach Road, Foot Bridge, Cofferdam, Compound Wall, Scada And Automation, Cwr Pumps Etc Are To Be Considered Extra. 921 0.2 Mld 922 0.3 Mld 923 0.4 Mld 924 0.5 Mld 925 0.6 Mld 926 M1055pumps 927 Supplying100 Mm Dia Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene / Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon / Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single / Double Run Shall Be Provided With Each Pump. 928 Submersible Pump Set 100 Mm Dia ( With Polypropylene / Noryl Impeller ) Up To 20 Stages 929 1 H.P. 930 1.5Hp 931 2 Hp 932 2.5 Hp 933 3.0 Hp 934 4.0 Hp 935 5.0 Hp 936 Supply Rate Should Be Increased By Rs 200 / - Per Stage For Pump With More Than 20 Stages 937 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 8 Stages 938 1.5 Hp 939 2.0 Hp 940 3.0 Hp 941 4.0 Hp 942 5.0 Hp 943 6.0 Hp 944 7.5 Hp 945 Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 8 Stages 946 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 12 Stages 947 8.0 Hp 948 9.0 Hp 949 10.0 Hp 950 11.0 Hp 951 12.5 Hp 952 15.0 Hp 953 Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 12 Stages 954 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 20 Stages 955 17.5 Hp 956 20.0 Hp 957 25 Hp 958 1 ) Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 20 Stages For Bore Well Only. 959 For Other Use 200 Mm Dia Pump Shall Be Preferred Over 150 Mm Dia With More Than 20 Stage Pump. 960 2 ) For 150 Mm Dia Energy Efficient Pumps Add As Below 961 A. Up To 8 Stages :- 3% On Supply Rate 962 B. Up To 12 Stages :- 4% On Supply Rate 963 C. Up To 15 Stages :- 5% On Supply Rate 964 M1056pressure Gauge 965 Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint 966 Pressure Gauge ( 100 Mm Dia ) 967 Pressure Gauge ( 150 Mm Dia ) 968 Vacuum / Combination Gauge 969 Supplyingvacuum Gauge / Combination Gauge Of Required Range Complete With Syphon Tube, Isolating Cock Suitable For 12 Mm Dia G.I. Pipe. 970 Vacuum / Combination Gauge – 100 Mm Dia 971 Vacuum / Combination Gauge – 150 Mm Dia 972 M1057lifting Equipment 973 Chain Pulley Block 974 Supplyingtriple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. 975 1 Tonne Capacity 976 2 Tonne Capacity 977 3 Tonne Capacity 978 Hand Operated Circular Or Rectangular Travelling Crane ( Single Girder ) 979 Supplyingsingle Girder Hand Operated Circular / Rectangular Travelling Crane With 6 M Lift Complete With Chain Pulley Block Isi Marked And Travelling Trolley Both Tested For 50% Overload Including Arrangement For Longitudinal Travel / Circular Travel And Cross Travel With Wheel, Hand Chain, Etc Complete. 980 3 Tonne Capacity 981 Up To 5 M Span 982 Above 5 M Up To 6 M Span 983 Above 6 M Up To 8 M Span 984 5 Tonne Capacity 985 Up To 5 M Span 986 Above 5 M Up To 6 M Span 987 Above 6 M Up To 8 M Span 988 Above 8 M Up To 10 M Span 989 Electric Operated Circular Or Rectangular Travelling Crane ( Single Girder ) 990 Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. 991 5 Tonne Capacity 992 Above 6 M Up To 8 M Span 993 Above 8 M Up To 10 M Span 994 7.5 Tonne Capacity 995 Above 6 M Upto 8 M Span 996 Above 8 M Up To 10 M Span 997 10 Tonne Capacity 998 Above 6 M Up To 8 M Span 999 Above 8 M Up To 10 M Span 1000 Square Bar / Rail 1001 Providing, Erecting And Fixing Square Bar Of En 8 As Rail For Over Head Crane On Provided Track, Girder / Continuous Corbel Beam, Including Supporting Plate And “J” Bolts. 1002 50 X 50 Mm ( En 8 ) 1003 40 X 40 Mm ( En 8 ) 1004 M1058lightening Arrester, Ab Switch, Insulators 1005 Lightening Arrestor 1006 Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. 1007 Suitable For 11 Kv Supply, Distribution Class 1008 Suitable For 22 Kv Supply, Distribution Class 1009 Suitable For 33 Kv Supply, Station Class 1010 Disc Insulator 1011 Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm 1012 Suitable For 11Kv Line 1013 Suitable For 33Kv Line 1014 Pin Insulator 1015 Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm 1016 Suitable For 11Kv Line 1017 Suitable For 33Kv Line 1018 Air Break Switch Without Earth Switch 1019 Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 1020 Suitable For 11Kv Line 1021 Rocking / Tilting Type 1022 Rotating Type 1023 Suitable For 33Kv Line 1024 Rocking / Tilting Type 1025 Rotating Type 1026 Air Break Switch With Earth Switch 1027 Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 1028 Suitable For 11Kv Line 1029 Rotating Type 1030 Suitable For 33Kv Line 1031 Rotating Type 1032 Drop Out Fuse ( Channel Mounted ) 1033 Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Currentup To 50 Amp, Capacity Completeerected On Provided Cross Arm, Each Set Comprising 3 Units 1034 Suitable For 11 Kv Line 1035 Suitable For 33 Kv Line 1036 Horn Gap Fuse ( Channel Mounted ) 1037 Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units 1038 Suitable For 11 Kv Line 1039 Suitable For 33 Kv Line 1040 M1059transformer 1041 Power Transformer ( With Off Load Tap Changer ) Any Isi Mark 1042 Supplyingoutdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 450 C By Thermometer In Oil And 500 C By Theresistance In Winding After Continuous Run At Full Load Rating, Thetransformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provideseparateearthing. The Transformer Shall Have Power Terminal Arrangement, Bushing / Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1043 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 1044 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 1045 3. Oil Drain Valve 1046 4. Oil Filter Valve 1047 5. Lifting Eyes / Hooks 1048 6. Two Earthing Terminals 1049 7. Diagram And Rating Plate 1050 8. Air Vent 1051 9. Explosion Vent 1052 10. 100Mm Dia Thermo Meter With Thermometer Pocket 1053 11. Four Bi Directional Plain Roller. 1054 Power Transformer 11000 / 433 Volts With Off Load Tap Changer – 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. 1055 63 Kva ( No Load Loss 180W And Load Loss 1235W ) 1056 100 Kva ( No Load Loss 260W And Load Loss 1760W ) 1057 160Kva ( No Load Loss 260W And Load Loss 1760W ) 1058 200Kva ( No Load Loss 500W And Load Loss3000w ) 1059 250Kvaa ( No Load Loss 550W And Load Loss3600w ) 1060 315Kva ( No Load Loss 580W And Load Loss 4200W ) 1061 400 Kva ( No Load Loss 715W And Load Loss 5000W ) 1062 500 Kva ( No Load Loss 850W And Load Loss 5800W ) 1063 630 Kva ( No Load Loss 1000W And Load Loss 7000W ) 1064 750 Kva ( No Load Loss 1500W And Load Loss 8000W ) 1065 Power Transformer ( With On Load Tap Changer ) 1066 Supplyingoutdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 450 C By Thermometer In Oil And 500 C By Theresistance In Winding After Continuous Run At Full Load Rating, Thetransformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provideseparateearthing. The Transformer Shall Have Power Terminal Arrangement, Bushing / Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1067 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 1068 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 1069 3. Oil Drain Valve 1070 4. Oil Filter Valve 1071 5. Lifting Eyes / Hooks 1072 6. Two Earthing Terminals 1073 7. Diagram And Rating Plate 1074 8. Air Vent 1075 9. Explosion Vent 1076 10. 100Mm Dia Thermo Meter With Thermometer Pocket 1077 11. Four Bi Directional Plain Roller. 1078 12. Buchholz Relay 1079 13. Resistance Temp. Detector 1080 14. Marshalling Box 1081 15. Automatic Voltage Regulator ( Avr ) 1082 16. Remote Tap Changing Controller ( Rtcc ) 1083 Transformer 11000 / 433 Volts Withon Load Tap Changer – 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification As Per Bis Level-2. 1084 750 Kva 1085 1000 Kva 1086 1250 Kva 1087 1600 Kva 1088 2000 Kva 1089 M1060motors 1090 Foot Mounted Motors Tefc 1500 Rpm 1091 Supplyingfoot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts + / -10%, 3 Phase, 50 Hz + / -3% With “F” Class Insulation Temperature Rise Limited To Class “B” Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. 1092 15 Kw ( 20 Hp ) 1093 18.5 Kw ( 25 Hp ) 1094 22 Kw ( 30 Hp ) 1095 30 Kw ( 40 Hp ) 1096 37 Kw ( 50 Hp ) 1097 45 Kw ( 60 Hp ) 1098 55 Kw ( 75 Hp ) 1099 75 Kw ( 100 Hp ) 1100 90 Kw ( 120 Hp ) 1101 110 Kw ( 150 Hp ) 1102 132Kw ( 180Hp ) 1103 160Kw ( 215 Hp ) 1104 250Kw ( 335 Hp ) 1105 Foot Mounted Motor Tefc 1500 Rpm 1106 0.75 Kw ( 1Hp ) 1107 1.1 Kw ( 1.5 Hp ) 1108 1.5 Kw ( 2 Hp ) 1109 2.2 Kw ( 3 Hp ) 1110 3.7 Kw ( 5 Hp ) 1111 5.5 Kw ( 7.5 Hp ) 1112 7.5 Kw ( 10 Hp ) 1113 9.3 Kw ( 12.5 Hp ) 1114 11 Kw ( 15 Hp ) 1115 M1061aluminium Cable 1116 Cable 1117 Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . 1118 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1119 3 Core 2.5 Sq Mm 1120 3 Core 4 Sq Mm 1121 3 Core 6 Sq Mm 1122 3 Core 10 Sq Mm 1123 3 Core 16 Sq Mm 1124 3 Core 25 Sq Mm 1125 3 Core 35 Sq Mm 1126 3 Core 50 Sq Mm 1127 3 Core 70 Sq Mm 1128 3 Core 95 Sq Mm 1129 3 Core 120 Sq Mm 1130 3 Core 150 Sq Mm 1131 3 Core 185 Sq Mm 1132 3 Core 240 Sq Mm 1133 3 Core 300 Sq Mm 1134 3 Core 400 Sq Mm 1135 Aluminium Conductor 3.5 Core, Xlpe / Pvc Insulated & Unarmoured Cable 1136 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three And Half Core, Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Completein An Approved Manner. 1137 3.5 Core 25 Sq Mm 1138 3.5 Core 35 Sq Mm 1139 3.5 Core 50 Sq Mm 1140 3.5 Core 70 Sq Mm 1141 3.5 Core 95 Sq Mm 1142 3.5 Core 120 Sq Mm 1143 3.5 Core 150 Sq Mm 1144 3.5 Core 185 Sq Mm 1145 3.5 Core 240 Sq Mm 1146 3.5 Core 300 Sq Mm 1147 3.5 Core 400 Sq Mm 1148 Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated 1149 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1150 3 Core 35 Sq Mm 1151 3 Core 50 Sq Mm 1152 3 Core 70 Sq Mm 1153 3 Core 95 Sq Mm 1154 3 Core 120 Sq Mm 1155 3 Core150sq Mm 1156 3 Core 185 Sq Mm 1157 3 Core 240Sq Mm 1158 3 Core 300 Sq Mm 1159 3 Core 400 Sq Mm 1160 Ht Aluminium Three Core 6.6 Kv ( Ue ) / 11Kv Ecable Xlpe Insulated 1161 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1162 3 Core 35 Sq Mm 1163 3 Core 50 Sq Mm 1164 3 Core 70 Sq Mm 1165 3 Core 95 Sq Mm 1166 3 Core 120 Sq Mm 1167 3 Core150sq Mm 1168 3 Core 185 Sq Mm 1169 3 Core 240Sq Mm 1170 3 Core 300 Sq Mm 1171 3 Core 400 Sq Mm 1172 Ht Aluminium Three Core 11Kv ( Ue ) Cable Xlpe Insulated 1173 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1174 3 Core 35 Sq Mm 1175 3 Core 50 Sq Mm 1176 3 Core 70 Sq Mm 1177 3 Core 95 Sq Mm 1178 3 Core 120 Sq Mm 1179 3 Core150sq Mm 1180 3 Core 185 Sq Mm 1181 3 Core 240Sq Mm 1182 3 Core 300 Sq Mm 1183 3 Core 400 Sq Mm 1184 Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable . 1185 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1186 3 Core 4 Sq Mm 1187 3 Core 6 Sq Mm 1188 3 Core 10 Sq Mm 1189 3 Core 16 Sq Mm 1190 3 Core 25 Sq Mm 1191 3 Core 35 Sq Mm 1192 3 Core 50 Sq Mm 1193 3 Core 70 Sq Mm 1194 3 Core 95 Sq Mm 1195 3 Core 120 Sq Mm 1196 3 Core 150 Sq Mm 1197 3 Core 185 Sq Mm 1198 3 Core 240 Sq Mm 1199 3 Core 300 Sq Mm 1200 3 Core 400 Sq Mm 1201 M1062copper Cable 1202 Cable 1203 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . 1204 Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . 1205 3 Core 1.5 Sq Mm 1206 3 Core 2.5 Sq Mm 1207 3 Core 4 Sq Mm 1208 3 Core 6 Sq Mm 1209 3 Core 10 Sq Mm 1210 3 Core 16 Sq Mm 1211 3 Core 25 Sq Mm 1212 3 Core 35 Sq Mm 1213 Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable . 1214 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1215 3 Core 1.5 Sq Mm 1216 3 Core 2.5 Sq Mm 1217 3 Core 4 Sq Mm 1218 3 Core 6 Sq Mm 1219 3 Core 10 Sq Mm 1220 3 Core 16 Sq Mm 1221 3 Core 25 Sq Mm 1222 3 Core 35 Sq Mm 1223 3 Core 50 Sq Mm 1224 3 Core 70 Sq Mm 1225 3 Core 95 Sq Mm 1226 Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . 1227 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Completein An Approved Manner. 1228 3.5 Core 1.5 Sq Mm 1229 3.5 Core 2.5 Sq Mm 1230 3.5 Core 4 Sq Mm 1231 3.5 Core 6 Sq Mm 1232 3.5 Core 10 Sq Mm 1233 3.5 Core 16 Sq Mm 1234 3.5 Core 25 Sq Mm 1235 3.5 Core 35 Sq Mm 1236 3.5 Core 50 Sq Mm 1237 3 .5 Core 70 Sq Mm 1238 3.5 Core 95 Sq Mm 1239 3.5 Core 120 Sq Mm 1240 3 .5 Core150sq Mm 1241 3.5 Core 185 Sq Mm 1242 3.5 Core 240Sq Mm 1243 3.5 Core 300 Sq Mm 1244 3.5 Core 400 Sq Mm 1245 Copper Conductor 3.5 Core Xlpe / Pvcunarmoured 1246 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1247 3.5Core 25 Sq Mm 1248 3.5Core 35 Sq Mm 1249 3.5 Core 50 Sq Mm 1250 3.5 Core 70 Sq Mm 1251 3.5 Core 95 Sq Mm 1252 3.5 Core 120 Sq Mm 1253 3.5 Core150sq Mm 1254 3.5 Core 185 Sq Mm 1255 3.5 Core 240Sq Mm 1256 3.5 Core 300 Sq Mm 1257 3.5 Core 400 Sq Mm 1258 Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . 1259 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1260 3 Core 1.5 Sq Mm 1261 3 Core 2.5 Sq Mm 1262 3 Core 4 Sq Mm 1263 3 Core 6 Sq Mm 1264 3 Core 10 Sq Mm 1265 3 Core 16 Sq Mm 1266 3 Core 25 Sq Mm 1267 3 Core 35 Sq Mm 1268 3 Core 50 Sq Mm 1269 3 Core 70 Sq Mm 1270 3 Core 95 Sq Mm 1271 3 Core 120 Sq Mm 1272 3 Core 150Sq Mm 1273 3Core 185 Sq Mm 1274 3 Core 240 Sq Mm 1275 3 Core 300 Sq Mm 1276 3 Core 400 Sq Mm 1277 M1063foot Valve 1278 Foot Valve 1279 Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. 1280 Flanged Type 1281 50 Mm 1282 65 Mm 1283 80 Mm 1284 100 Mm 1285 125 Mm 1286 150 Mm 1287 M1064aircircuit Breaker 1288 Acbbreaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole 1289 630A 1290 800A 1291 1000A 1292 1250A 1293 1600A 1294 2000A 1295 M1065starter 1296 D.O.L. Starter With Ss Enclosure With 380 / 415 Volt Coil 1297 7.5 H.P. 1298 10 H.P. 1299 Supplyingfully Automatic Star Delta Starter To Operate Induction Motor Working On415v, 3Phase, 50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser 1300 F.A.S.D Starter 1301 10.0 H.P. 1302 15 H.P. 1303 20 H.P. 1304 25 H.P. 1305 35 H.P. 1306 40 Hp 1307 50 Hp 1308 75 H.P. 1309 100 H.P. 1310 125 H.P. 1311 150 H.P. 1312 250 H.P. 1313 M1066servo Controlled Automatic Voltage Stabilizer 1314 Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt + / -1%, 3 Ph, 50 Hz, With Copper Wound Transformer ( Air / Oil Cooled ) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And UserS Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto / Manual Selector Switch, Raise / Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated?? Over Voltage / Under Voltage?? Single Phasing?? Cut Off Contactor With Electronic Output Sensing Unit 1315 Servo Controlled Automatic Voltage Stabiliser ( Out Put 415 + / -1% ) Input 150 To 450 Volt 1316 20 Kva Air Cooled 1317 25 Kva Air Cooled 1318 30 Kva Air Cooled 1319 40 Kva Air Cooled 1320 50 Kva Oil Cooled 1321 60 Kva Oil Cooled 1322 75 Kva Oil Cooled 1323 100 Kva Oil Cooled 1324 125 Kva Oil Cooled 1325 Servo Controlled Automatic Voltage Stabiliser ( Out Put 415 + / -1% ) Input 280 To 460 Volt 1326 15 Kva Air Cooled 1327 20 Kva Air Cooled 1328 25 Kva Air Cooled 1329 30 Kva Air Cooled 1330 40 Kva Air Cooled 1331 50Kva Air Cooled 1332 60 Kva Oil Cooled 1333 75Kva Oil Cooled 1334 100 Kva Oil Cooled 1335 125 Kva Oil Cooled 1336 150 Kva Oil Cooled 1337 200Kva Oil Cooled 1338 250Kva Oil Cooled 1339 300 Kva Oil Cooled 1340 400 Kva Oil Cooled 1341 M1067termination Kit 1342 Providing And Errecting In-Door Type Termination Kit, For 3.3Kv / 6.6 Kv / 11Kv / 22Kv / 33Kv Xlpe Screened 3 Core Cable 1343 In-Door Termination Kit For 3.3Kv ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1344 25-50 Mm2 1345 70-120 Mm2 1346 150-185 Mm2 1347 240-400 Mm2 1348 Out-Door Termination Kit For 3.3 ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1349 25-50 Mm2 1350 70-120 Mm2 1351 150-185 Mm2 1352 240-400 Mm2 1353 Straight Through Joint For 3.3Kv ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1354 25-50 Mm2 1355 70-120 Mm2 1356 150-185 Mm2 1357 240-300 Mm2 1358 In Door Termination Kit For 11Kv ( E ) Xlpe Screened 3 Core Cable 1359 25-50 Mm2 1360 70-120 Mm2 1361 150-185 Mm2 1362 240-400 Mm2 1363 Out Door Termination Kit For 11Kv ( E ) Xlpe Screened 3 Core Cable 1364 25-50 Mm2 1365 70-120 Mm2 1366 150-185 Mm2 1367 240-400 Mm2 1368 Straight Through Joint For 11 Kv ( E ) Xlpe Screened 3 Core Cable 1369 25-50 Mm2 1370 70-120 Mm2 1371 150-185 Mm2 1372 240-300 Mm2 1373 In Door Termination Kit For 22Kv ( E ) Xlpe Screened 3 Core Cable 1374 25-50 Mm2 1375 70-120 Mm2 1376 150-185 Mm2 1377 240-400 Mm2 1378 Out Door Termination Kit For 22Kv ( E ) Xlpe Screened 3 Core Cable 1379 25-50 Mm2 1380 70-120 Mm2 1381 150-185 Mm2 1382 240-400 Mm2 1383 Straight Through Joint For 22 Kv ( E ) Xlpe Screened 3 Core Cable 1384 25-50 Mm2 1385 70-95 Mm2 1386 120-150 Mm2 1387 185-240 Mm2 1388 300-400 Mm2 1389 In Door Termination Kit For 33Kv ( E ) Xlpe Screened 3 Core Cable 1390 25-50 Mm2 1391 70-95 Mm2 1392 120-185 Mm2 1393 240-400 Mm2 1394 Out Door Termination Kit For 33 Kv ( E ) Xlpe Screened 3 Core Cable 1395 25-50 Mm2 1396 70-95 Mm2 1397 120-185 Mm2 1398 240-400 Mm2 1399 Straight Through Joint For 33 Kv ( E ) Xlpe Screened 3 Core Cable 1400 35-70 Mm2 1401 95-150 Mm2 1402 185-300 Mm2 1403 400 Mm2

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:PROCUREMENT OF RATE OF MATERIALS.
Sl. No. Item Description
1M079- Polythene water storage tank of ISI mark (e.g sintex/sinter/himgiri/gangotietc)with cover and locking system
2M193 GI Pipe 50 mm dia (TATA or equivalent make)
3M337 Jute
4M922 G.M. Ferrules
5(i) 8 mm dia Wt. not less than 400 gms
6(ii) 10 mm dia Wt. not less than 400 gms
7(iii) 15 mm dia Wt. not less than 400 gms
8(iv) 20 mm dia Wt. not less than 600 gms
9(v) 25 mm dia Wt. not less than 900 gms
10M923 Stop Cocks
11(i) 15 mm brass stop cock wt. not less than 300 gms
12(ii) 20 mm brass stop cock wt. not less than 400 gms
13(iii) 25 mm brass stop cock wt. not less than 575 gms
14(iv) 32 mm brass stop cock wt. not less than 850 gms
15(v) 40 mm brass stop cock wt. not less than 1.15 kg
16(vi) 50 mm brass stop cock wt. not less than 2.15 kg
17(vii) 15 mm dia C.I. Body brass working part stop cock.
18(viii) 20 mm dia C.I. Body brass working part stop cock.
19(ix) 25 mm dia C.I. Body brass working part stop cock.
20M924 G.M. Full way Valve
21(i) 15 mm dia wt. not less than 300 gms without wheel
22(ii) 20 mm dia wt. not less than 400 gms without wheel
23(iii) 25 mm dia wt. not less than 500 gms without wheel
24(iv) 32 mm dia wt. not less than 700 gms without wheel
25(v) 40 mm dia wt. not less than 1.0 kg without wheel
26(vi) 50 mm dia wt. not less than 1.4 kg without wheel
27(vii) 65 mm dia wt. not less than 1.8 kg without wheel
28(viii) 80 mm dia wt. not less than 2.5 kg without wheel
29M925 G.M. NON RETURN VALVE VERTICAL
30(i) 15 mm dia wt. not less than 150 gms
31(ii) 20 mm dia wt. not less than 250 gms
32(iii) 25 mm dia wt. not less than 375 gms
33(iv) 32 mm dia wt. not less than 600 gms
34(v) 40 mm dia wt. not less than 700 gms
35(vi) 50 mm dia wt. not less than 1.0 kg
36(vii) 65 mm dia wt. not less than 1.20 kg
37(viii) 80 mm dia wt. not less than 1.50 kg
38(ix) 100 mm dia wt. not less than 1.80 kg
39M926 G.M. Non Return Valve Horizontal
40(i) 15 mm dia wt. not less than 150 gms
41(ii) 20 mm dia wt. not less than 250 gms
42(iii) 25 mm dia wt. not less than 375 gms
43(iv) 32 mm dia wt. not less than 600 gms
44(v) 40 mm dia wt. not less than 700 gms
45(vi) 50 mm dia wt. not less than 1.0 kg
46(vii) 65 mm dia wt. not less than 1.20 kg
47(viii) 80 mm dia wt. not less than 1.50 kg
48(ix) 100 mm dia wt. not less than 1.80 kg
49M927 COCKs
50(i) 15 mm dia G.M. bib cock wt. not less than 300 gms
51(ii) 15 mm dia brass bib cock wt. not less than 400 gms
52(iii) 15 mm dia C.I. bib cock wt. not less than 400 gms
53(iv) 15 mm dia C.I. Body brass working part spray painted bib cock wt. not less than 400 gms
54(v) 15 mm dia C.I. Brass pillar cock cock wt. not less than 400 gms
55(vi) 15 mm C.I. Plug cock ordinary
56(vii) 15 mm C.I. push cock ordinary
57M928 CHROMIUM PLATED BRASS FITTINGS
58(i) C.P. Shower rose 100 mm dia
59(ii) C.P. Shower rose 125 mm dia
60(iii) P.V.C. Shower rose 150 mm dia
61(iv) P.V.C Shower rose 125 mm dia
62M929 CONNECTION PIPE
63(i) 15 mm dia x 30 cm. long lead connection pipe with brass fittings.
64(ii) 15 mm dia x 45 cm. long lead connection pipe with brass fittings.
65(iii) 15 mm dia x 30 cm. long PVC connection pipe with brass fittings.
66(iv) 15 mm dia x 45 cm. long PVC connection pipe withbrass fittings.
67M930 G.I. FITTINGS (CONFORMING TO I.S. - 1879 ) ISI Marked
68[A] G.I. BEND
69(i) 15 mm
70(ii) 20 mm
71(iii) 25 mm
72(iv) 32 mm
73(v) 40 mm
74(vi) 50 mm
75(vii) 65 mm
76(viii) 80 mm
77(ix) 100 mm
78(x) 125 mm
79(xi) 150 mm
80[B] ELBOW OF THE FOLLOWING SIZES
81(i) 15 mm
82(ii) 20 mm
83(iii) 25 mm
84(iv) 32 mm
85(v) 40 mm
86(vi) 50 mm
87(vii) 65 mm
88(viii) 80 mm
89(ix) 100 mm
90(x) 125 mm
91(xi) 150 mm
92[C] TEE PLAIN OF THE FOLLOWING SIZES
93(i) 15 mm
94(ii) 20 mm
95(iii) 25 mm
96(iv) 32 mm
97(v) 40 mm
98(vi) 50 mm
99(vii) 65 mm
100(viii) 80 mm
101(ix) 100 mm
102(x) 125 mm
103(xi) 150 mm
104[D] REDUCING TEE PLAIN OF THE FOLLOWING SIZES(Taking larger dimension)
105(i) 20 mm
106(ii) 25 mm
107(iii) 32 mm
108(iv) 40 mm
109(v) 50 mm
110(vi) 65 mm
111(vii) 80 mm
112(viii) 100 mm
113(ix) 125 mm
114(x) 150 mm
115[E] SOCKET PLAIN OF THE FOLLOWING SIZE (Taking larger dimension)
116(i) 15 mm
117(ii) 20 mm
118(iii) 25 mm
119(iv) 32 mm
120(v) 40 mm
121(vi) 50 mm
122(vii) 65 mm
123(viii) 80 mm
124(ix) 100 mm
125(x) 125 mm
126(xi) 150 mm
127[F] REDUCING SOCKET PLAIN OF THE FOLLOWING SIZES (Taking larger dimension)
128(i) 20 mm
129(ii) 25 mm
130(iii) 32 mm
131(iv) 40 mm
132(v) 50 mm
133(vi) 65 mm
134(vii) 80 mm
135(viii) 100 mm
136(ix) 125 mm
137(x) 150 mm
138[G] UNION SOCKET OF THE FOLLOWING SIZES
139(i) 15 mm
140(ii) 20 mm
141(iii) 25 mm
142(iv) 32 mm
143(v) 40 mm
144(vi) 50 mm
145(vii) 65 mm
146(viii) 80 mm
147(ix) 100 mm
148(x) 125 mm
149(xi) 150 mm
150[H] PLUGS OF THE FOLLOWING SIZES
151(i) 15 mm
152(ii) 20 mm
153(iii) 25 mm
154(iv) 32 mm
155(v) 40 mm
156(vi) 50 mm
157(vii) 65 mm
158(viii) 80 mm
159(ix) 100 mm
160(x) 125 mm
161(xi) 150 mm
162[I] JAM NUTS OF THE FOLLOWING SIZES
163(i) 15 mm
164(ii) 20 mm
165(iii) 25 mm
166(iv) 32 mm
167(v) 40 mm
168(vi) 50 mm
169(vii) 65 mm
170(viii) 80 mm
171(ix) 100 mm
172(x) 125 mm
173(xi) 150 mm
174[J] G.I. NIPPLE OF THE FOLLOWING SIZES
175(i) 15 mm dia x 100 mm long
176(ii) 20 mm dia x 100 mm long
177(iii) 25 mm dia x 100 mm long
178(iv) 32mm dia x 100 mm long
179(v) 40 mm dia x 100 mm long
180(vi) 50 mm dia x 100 mm long
181(vii) 65 mm dia x 100 mm long
182(viii) 80 mm dia x 100 mm long
183(ix) 100 mm dia x 100 mm long
184[K] G.I. PIPES MIDIUM(Tata mark) OR EQUIVALENT as per IS-1239 (part-01)/2004 ISI Marked/Medium Quality
185(i) 15 mm dia
186(ii) 20 mm dia
187(iii) 25 mm dia
188(iv) 32 mm dia
189(v) 40 mm dia
190(vii) 65 mm dia
191M931 MIRRORS
192(a) Mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingC.P. brass revolving fittings 3 mm plywood boardand C.P. hinges etc.to fix the mirror
193(b) -do- 450 mm x 300 mm -do-
194M932 (a) Glass shelf 600 mm x 125 mm with C.P. brass rail
195(b) -do- 450 mm x 125 mm -do-
196M933 (a) C.P. Brass towel rail 20 mm x 600 mm with bracket all complete
197(b) Anodized aluminum 20 mm x 600 mm towel rail complete with brackets
198M934 C.P. brass soap dish medium quality with screw andhinges etc.
199M935 C.P. liquid soap solution holder
200M936 VITREOUS WHITE GLAZED INDIAN WATER CLOSET OF Hindustan / Parry Ware / Cera / Naycer or anyotherequivalent make
201(a) 580 mm long
202(b) 510 mm long
203(c) 450 mm long
204(d) 510 mm long White glazed fiber I.W.C
205M937 PAIR OF VETREOUS WHITE GLAZED FOOT REST OF Hindustan / Parryware / Cera / Naycer or any other equivalent make
206M938 15 liters capacity pull and let go high level C.I. cistern complete with ball cock and a pair of bracket
207M939 (a) 12.5 liters lowdown C.I. Cistern
208(b) 10.0 liters capacity P.V.C. low design cistern
209M940 (a) White Glazed vitreous E.W.C with "P" trap orany other equivalent make
210(b) E.W.C with "S" trap 400 mm high of Hindustan / Parry ware / Cera / Naycear or any other equivalent make
211(c) Black / white plastic seat for E.W.C -do- as above.
212M941 (a) White glazed vitreous earthen were urinal flat back of Hindustan / Parryware / Cera / Naycer or any other equivalent make 600 mm x 350 mm size
213(b) -do- squatting small 450 mm x 350 mm
214(c) -do- squatting large 600 mm x 350 mm
215(d) White glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm Hindustan / Parryware /Cera / Naycer or any other equivalent make
216(e) Partition plate for urinal 25" x 13" size
217(f) 5 liters C.I. automatic cistern with all P.V.C fittings
218M942 White glazed vitreous Wash Hand Basin 550 mm x 400mm size of Hindustan / Parryware / Cera / Naycer or any otherequivalent make
219M943 White glazed vitreous earthen ware kitchensinks of Hindustan / Parryware / Cera / Nayceror any other equivalent make
220(a) Kitchen sink 600 mm x 450 mm x 200 mm (24" x 18" x 8")
221(b) Kitchen sink 600 mm x 450 mm x 250 mm (24" x 18" x 10")
222(c) Lab sink 450 mm x 300 mm x 150 mm (18" x 12" x 6")
223(d) Lab sink 300 mm x 250 mm x 150 mm (12" x 10" x 6")
224M944 DRAIN BOARD
225(a) 600 mm x 450 mm (24" x 18")
226(b) 525 mm x 450 mm (21" x 18")
227M945 H.C.I. Pipes
228(a) 50 mm dia single socket 6"-0" (with ear weight 13 kg)
229(b) 80 mm dia single socket 6"-0" (with ear weight 18 kg)
230(c) 100 mm dia single socket 6"-0" (with ear weight 23 kg)
231(d) 150 mm dia single socket 6"-0" (with ear weight 30 kg)
232(e) 50 mm dia double socket 6"-0" (with ear weight 14 kg)
233(f) 80 mm dia double socket 6"-0" (with ear weight 19 kg)
234(g) 100 mm dia double socket 6"-0" (with ear weight 25 kg)
235(h) 150 mm dia double socket 6"-0" (with ear weight 13 kg)
236(i) 50 mm dia single socket 3"-0" (with ear weight 7.25 kg)
237(j) 80 mm dia single socket 3"-0" (with ear weight 10.5 kg)
238(k) 100 mm dia single socket 3"-0" (with ear weight 13.75 kg)
239(l) 150 mm dia single socket 3"-0" with ear
240(m) 50 mm dia single socket 2"-0" (with ear weight 5.35 kg)
241(n) 80 mm dia single socket2"-0" (with ear weight 8.00 kg)
242(o)100 mm dia single socket 2"-0"(with ear weight 10.10 kg)
243(p) 150 mm dia single socket 2"-0" with ear
244(q) 50 mm dia single socket 1"-0" (with ear weight 3.4 kg)
245(r) 80 mm dia single socket 1"-0"(with ear weight 5.50 kg)
246(s) 100 mm dia single socket 1"-0"(with ear weight 7.60 kg)
247(t) 150 mm dia single socket
248M946 H.C.I. FITTINGS.
249(I) Plain bend of following size
250(a) 50 mm dia (weight without ear and socket 2.75 kg)
251(b) 80 mm dia (weight without ear and socket 3.5 kg)
252(c) 100 mm dia (weight without ear and socket 4.5 kg)
253(d) 150 mm dia (weight without ear and socket 4.5 kg)
254(II) Bend with door with following size
255(a) 50 mm dia (Wight without ear and socket 2.75 kg)
256(b) 80 mm dia (Wight without ear and socket 4.00 kg)
257(c) 100 mm dia -do- 5.5 kg
258(d) 150 mm dia -do-
259(III) Single Junction with door of followings sizes.
260(a) 50 mm dia (weight without ear and socket 3.75 kg)
261(b) 80 mm dia (weight without ear and socket 6.50 kg)
262(c) 100 mm dia -do- 9.50 kg
263(d) 150 mm dia -do-
264(IV) Double junction with door of following sizes.
265(a) 50 mm dia -do- 4.5 kg
266(b) 80 mm dia -do- 7.00 kg
267(c) 100 mm dia -do- 13.00 kg
268(d) 150 mm dia -do-
269(V) Heel rest bend of following sizes
270(a) 50 mm dia
271(b) 80 mm dia
272(c) 100 mm dia
273(d) 150 mm dia
274(VI) Cowel of following sizes
275(a) 50 mm dia (weight without ear and socket 2.25 kg)
276(b) 80 mm dia (weight without ear and socket 3.25 kg)
277(c) 100 mm dia (weight without ear and socket 3.25 kg)
278(d) 150 mm dia -do-
279(VII) 100 mm dia "P" trap (wt without ear and socket)8.5 kg
280(VIII) 100 mm dia "P" trap (wt without ear and socket)8.8 kg
281(IX) 100 mm x 80 mm floor trap (weight without ear and socket) 4.00 kg
282(X) Pass over 50 mm x 150 mm for 50 mm projection
283(XI) -Do- 100 mm x 150 mm for 100 mm projection
284(XII) Inverted Junction single 100 mm x 50 (weight without ear and socket) 9.0 kg
285(XIII) Inverted Junction double 100 mm x 50 mm x 50 mm (weight without ear and socket) 12.0 kg
286(XIV) H.C.I. offset 80 mm projection of the following Size
287(a) 50 mm dia (weight without ear and socket) 2.75 kg
288(b) 80 mm dia -do- 3.50 kg
289(c) 100 mm dia -do- 5.00 kg
290(d) 150 mm dia -do-
291(XV) H.C.I. Socket of following sizes
292(a) 50 mm dia (weight without ear) 1.50 kg
293(b) 80 mm dia (weight without ear) 3.00 kg
294(c) 100 mm dia (weight without ear) 4.50 kg
295(d) 150 mm dia (weight without ear) -do-
296M947 C.I. Cover with frame for manhole and inspection chamber
297(a) 600 mm x 450 mm size (wt. 39 kg)
298(b) 600 mm x 450 mm size (wt. 25 kg)
299(c) 500 mm x 450 mm size (wt. 25 kg)
300M948 C.I. Bracket pair for W.H.B
301(a) 550 mm x 400 mm size (22" x 16")
302(b) -do- for 12.5 liter cistern
303(c) -do- for 600 mm x 450 mm (24" x 18") sink
304(d) 40 mm x 60 mm MS Plate bracket for sink as above
305M949 (a) 32 mm (1 1/4") C.P. Brass waste for W.H.B
306(b) 40 mm (1 1/2") C.P. Brass waste for W.H.B for sink
307(c) 32 mm (1 1/4") C.P. waste of white metal
308(d) 40 mm (1 1/2") C.P. waste of white metal
309M950 (a) 32 mm (1 1/4") P.V.C. waste pipe 750 mm long (2"6" long) withbrass Union for W H B
310(b) 40 mm (1 1/2") P.V.C. waste pipe 750 mm long(2"6" long)with brass Union for W H B
311M951 32 mm (1 1/4") P.V.C. telescopic flush pipe with brass union for high level cistern
312M952 Rubber Inserttion 3 mm (1/8") thick
313M953 Pig Lead
314M954 Yarn
315M955 Rubber Gasket for D.I pipe of Good quality
316(a) 80 mm
317(b)100 mm
318(c)125 mm
319(d)150 mm
320(e)200 mm
321(f)250 mm
322(g)300 mm
323(h)350 mm
324(i)400 mm
325(j)450 mm
326(k)500 mm
327(l)600 mm
328(m)700 mm
329(n)750 mm
330(o)800 mm
331(p)900 mm
332(q)1000 mm
333(r)1200 mm
334M956 Cotton waste
335M957 Asbestos Suta (gland packing)
336M958 Solvent Cement
337M959 Hydrocloric acid (Sepecific gravity 1.20)
338M960 CP & PVC Fitting
339(i)32 mm dia C.P. Waste
340(ii)32 mm dia PV C waste pipe 750 mm long with coupling
341(iii)40 mm dia C.P. waste
342(iv 40 mm dia PVC waste pipe 750 mm long with coupling
343(v 100 mm dia steel jali
344(vi)15 mm dia C.P. nipple with coupling (short pieces)
345(vii)50 mm dia PVC pipe with coupling
346M961 Special type of C.P. Bath room fittings for V.I.P.buildings(JAL, Jaquar, Marc or equivalent mark)
347(i) Pillar Cock (ISI)
348(ii) Pillar Cock (Long neck)
349(iii) Bib Cock (ISI)
350(iv) Bib Cock (Long Thread)
351(v) Angular Stop Cock
352(vi) Angular Stop Cock (Long Thread)
353(vii) Concealed stop cock reduce (ISI)
354(viii) Concealed stop Cock heavy-duty extra adjustable wall flange
355(ix) Long Body Bib Cock
356(x) Swan Neck Tap with left hand Operating Knob
357(xi) Central hole basin mixer (Best Quality)
358(xii) Wall mixer with telephonic shower arrangement
359(xiii) Wall mixer with provision for over head shower with elbow coupling and well flange
360(xiv) Wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange
361(xv) Sink mixer with swinging casted spout
362(xvi) Sink Cock with swinging casted spout
363(xvii) 4 - way diverter for concealed fittings
364(xviii) Pressure adjustable shower with revolving joint
365(xix) Telephone shower with flexible pipe
366(xx) Flush Cock with wall flange (25 mm)
367(xxi) Towel Rail 24"
368(xxii) Towel Ring
369(xxiii) Soap dish
370(xxiv) Tumbler Holder
371(xxv) Toilet Paper Holder
372(xxvi) Glass Shelf 22"
373(xxvii) Corner glass shelf with bracket
374(xxviii) Flush Valve complete with 32 mm size controlcock & flange
375M962 C.I Special & PVC Pipes
3761. C.I double shocketted fittings bend such as bend, tee, taper,
377(a) 80-200 mm
378(b) 250-700 mm
379(c) 700-1000 mm
3802. C.I double flange fittings such as tee, taper, tailpiece,bend etc
381(a) 80-200 mm
382(b) 250-700 mm
383(c) 700-1000 mm
384Spare parts of Hand Pump
385M963 Hexagonal Bolt M12x1.75x40mm long common to Marks II & III
386M964 Hexagonal Nut M12x1.75mm
387M965 Washer M12 (2.5mm thick)
388M966 High tensile bolt M10x1.5x40mm long.
389M967 Nyloc Nut M10x1.5mm
390M968 Handle Axle (Stainless Steel)
391M969 Washer for Handle Axle (4mm thick)
392M970 Ball Bearing 6204 Z
393M971 Spacer for Handle.
394M972 Chain with coupling.
395M973 Hexagonal Bolt for front Cover M12x1.75mm long.
396M974 Nitrile Rubber cup washer for Mark – II & III
397M975 Nitrile Sealing ring Mark – II
398M976 Nitrile Rubber Seating Big for Lower valve Mark-II
399M977 Nitrile Rubber Seating Small for Upper valve Mark-II.
400M978 Hexagonal rod coupling M12x1.75x50mm long.
401M979 Pump Head Assembly (G.I.) with front cover, Bolt & third plate.
402M980 Front cover (G.I.)
403M981 Handle Assembly (G.I.)
404M982 (a) Water Tank Assemblyfor Mark – II (G.I.)
405(b) Water Tank Assembly for Mark – III (VLOM-65)
406M983 Stand Assembly (G.I.) Normal.
407M984 Stand Assembly (Telescopic) (G.I).
408M985 Connecting Rod 3mtr. Long with coupling and nut (Electrogalvanized)
409M986 a) Cylinder Assembly complete set for Mark-II
410b) Cylinder Assembly complete set for Mark-III (VLOM-65)
411M987 a) Upper valve Assembly complete set for India Mark-II
412b) Upper valve Assembly complete set for India Mark-III (VLOM-65)
413M988 a) Lower valve Assembly complete set for India Mark-II
414b) Lower valve Assembly complete set for IM-III
415M989 Reducer Cap for Cylinder Mark-II
416M990 a) Plunger Rod (S.S.) for Mark – II
417b) Plunger Rod (S.S.) for Mark – III
418M991 Upper valve Guide (G.M.).
419M992 Rubber Seat Retainer for Mark-II
420M993 Third Plate for Head Assembly (Galanized)
421M994 Cylinder Body with brass liner for IM-II with reducer cap for Top and Bottom.
422M995 Gun Metal Spacer.
423M996 Check valve Guide Mark-II
424M997 a) Check Valve Seat for Mark – II
425b) Check Valve Seat for Mark – III
426M998 Nitrile Rubber “O” ring (VLOM-65)
427M999 Push Rod for Mark – III (S.S).
428M1000 Check Nut for Push Rod (S.S.).
429M1001 Nitrile Rubber Cup Washer for VLOM-50
430M1002 Nitrile Rubber Sealing Ring for Mark – III VLOM-65
431M1003 Nitrile Rubber Seating Big for Lower Valve MK-II
432M1004 Nitrile Rubber Seating Big for Lower Valve M-III VLOM-65)
433M1005 Nitrile Rubber Bobbin VLOM-50
434M1006 Nitrile Rubber “O” Ring VLOM-50
435M1007 Nitrile Rubber cone for VLOM-50
436M1008 Nitrile Rubber cone for VLOM-65
437M1009 Nitrile Rubber Centralizer 150mm for (VLOM-65).
438M1010 Nitrile Rubber Centralizer 125mm for (VLOM-65).
439M1011 Nitrile Rubber Centralizer 150mm for (VLOM-50).
440M1012 Nitrile Rubber Centralizer 125mm for VLOM-50
441M1013 Nitrile Rubber Centralizer 100mm for VLOM-50
442M1014 Water Tank Assembly Mark – III VLOM-50
443M1015 Cylinder Assembly Complete set for Mark – III (VLOM-50)
444M1016 Upper valve Assembly complete set for IM-III (VLOM-50)
445M1017 Lower valve Assembly complete set for IM-III (VLOM-50)
446M1018 a) Upper Cap Cylinder Mark – III (VLOM-65)
447b) Upper Cap Cylinder Mark – III (VLOM-50)
448M1019 a) Bottom Cap for Mark – III (VLOM-50)
449b) Bottom Capfor Mark – III (VLOM-65)
450M1020 Follower for IM-III
451M1021 Cage for Mark-III
452M1022 S.S. Hexagonal Bolt M-6x25mm long.
453M1023 Basic rate of standard I.S.I. mark Deep Well Hand Pump for India mark-2, I.S.I. 15500 (Part 2) / 2004 with latest revision including 12mm x 3meter long 8 no. Connecting Rods made of bright bar electro-galvanized fitted with coupler & normal stand assembly ecommended for use with cylinder assembly suitable for bore well dia 100 to 125mm casing pipe.
454M1024 Basic rate of UPVC pipe 125mm dia conforming to I.S.I. latest revision is 12818/2016 CML No. 5543459
455M1025 Basic rate of 32mm G.I. pipe in 3 mtrs. Length (medium) with seamless socket as per relevent B.I.S. specificationIS 1239(PART-I)/2004
456M1030 RCC ESR
457Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging Consisting of columns, internal and External bracings spaced vertically not More than 4.5 metres centre to centre for ESR having capacity upto 500 cum and Not more than 6m c/c for ESR having Capacity above 500 Cum including Excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all Columns and Bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder out side, Stainless Steel lader in contenor,C.I. manhole frame and covers, water level indicators,lightening conductor, G.I. pipe railing around walk way and top slab, providing stair case from ground level to roof level, M.S. Grill gate of 2M height with locking arrangement of approved design, B.B. Masonry chambers for all valves, ventilating shafts, providing and applying three coats of Acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti-termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per I.S. code. The job to include painting then ame of the scheme and other details on thereservoir as per the directions of Engineer In - Charge.
458Notes
459The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.)
460The design shall satisfy the stipulations as per I.S. 1893 -1984 and I.S.13920/1993 for seismic force and I.S.-11682 / 1985 for R.C.C. staging of over head tanks.
461For design having more than 6 columns, suitable bracing is obligatory.
462Plain round mild steel bars grade- I conforming to I.S.432 part-I orhigh yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall beused, grade- I Imildsteel bars will not be allowed
463Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level.
464These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral stair case for E.S.R. above 2 lakh litres capacity.
465Staging shall have to bede signed with stresses of M-200 concrete for ESR. However all RCC construction should be donein M-250. Structures in contact with water shall be designed & casted in M-300
466These rates are including the cost of up lift pressure if any and entire dewatering during execution. Incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition.
467All conditions given in the Member Secretary"s Circular No. MJP / TS-I / 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below.
46875 % part rate shall be payable for reinforcement concrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete.
469The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. The scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 M beyond outer face of outer most column ( Cost of pipe, specials and valves is taken as 10% of the cost of ESR as per table).
470For ESR upto 500 cum capacity C.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall be used. For ESR above 500 cum capacity C.I. / M.S. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti-corrosive epoxy treatment from in side and out side.
471Below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5 % where SBC is more than 5MT / sqm and upto 10 MT / sqm. This % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item.
472The rate shall be increased by 30 % for bearing piles upto depth of 10 M and for further increased in depth by 5 M each, it shall be increased by another 10%. These rates are applicable where raft is not feasible. For pile foundations sulphate resistant cement shall only beused. Single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of ESR.
473The rates are applicable for staging height of 12 M. These rates shall be increased or decreased for per metre variation in this staging height as below :
47412 to 16 M staging - 2% per metre
47516 to 20 M staging - 3% per metre
47620 M and above - 4% per metre
477For 17 M staging height, percentage calculation will be like below :
47812 to 16 M --- 4 x 2 = 8%
47916 & 17 M --- 1 x 3% = 3% Total = 11%
480For 21 M staging height, percentage calculation will be like below :
48112 to 16 M --- 4 x 2 = 8%
48216 to 20 M --- 4 x 3% = 12%
48320& 21 M --- 1 x 4% = 4% Total = 24%
484Following rates are for seismic zone III. For zone IV, these rates shall be increased by 5% and for zone II, these rates shall be decreased by 5%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. (Seismic maps attached in this CSR).
485Notes
486Conditions from Sr.No.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of R.C.C. E.S.R.
487Conditions from Sr.No.11 to 16 are for estimation purpose only and shall not appear in the tender.
488Rates for RCC ESRs
489Upto 25,000 litres
490Cost of 25,000 litres capacity
491Add for capacity above 25,000 upto 50,000 litres
492Cost of 50,000 litres capacity
493Add for capacity above 50,000 upto 75,000 litres
494Cost of 75,000 litres capacity
495Add for capacity above 75,000 upto 1,00,000 litres
496Cost of 1,00,000 litres capacity
497Add for capacity above 1,00,000 upto 1,50,000 litres
498Cost of 1,50,000 litres capacity
499Add for capacity above 1,50,000 upto 2,00,000 litres
500Cost of 2,00,000 litres capacity
501Add for capacity above 2,00,000 upto 2,50,000 litres
502Cost of 2,50,000 litres capacity
503Add for capacity above 2,50,000 upto 3,00,000 litres
504Cost of 3,00,000 litres capacity
505Add for capacity above 3,00,000 upto 4,00,000 litres
506Cost of 4,00,000 litres capacity
507Add for capacity above 4,00,000 upto 5,00,000 litres
508Cost of 5,00,000 litres capacity
509Add for capacity above 5,00,000 upto 7,50,000 litres
510Cost of 7,50,000 litres capacity
511Add for capacity above 7,50,000 upto 10,00,000 litres
512Cost of 10,00,000 litres capacity
513Add for capacity above 10,00,000 upto 15,00,000 litres
514Cost of 15,00,000 litres capacity
515Add for capacity above 15,00,000 upto 20,00,000 litres
516Cost of 20,00,000 litres capacity
517M1031 RCC GSR AND SUMP
518Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion. to inside face of the container,including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye-pass arrangement consisting of C.I./ M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications.
519Anti –termite treatment shall be given for under ground portion of the structure.
520Notes
521The design shall be in accordance with various relevant I.S. specification (I.S.456/2000,I.S.875-1987,I.S.3370-1965 or revised.)
522Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S.1139 shall be used.Grade- II M.S. bars shall not be used.
523Entire structure shall be in M-300 only.
524The scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.
525The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.
526The Job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineer-in-charge. If up lifts considered in design, then these rates shall be increased by 7.5%.
527G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.
528For pipe diameters upto 300mm only CIpipes and CI specials shall be used. For pipe diameters above 300mm, M.S. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside.
529Cost of pump house is not included in these rates.
530Above rates are applicable for Seismic Zones 2, 3 and 4.
53175% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.
53210% shall be added for sump if over head pump house is proposed.
533Note: Conditions from Sr.No.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C .GSRs and sumps.
534Rates for RCC GSRs and Sumps
535Upto 25,000 litres
536Cost of 25,000 litres capacity
537Add for capacity above 25,000 upto 50,000 litres
538Cost of 50,000 litres capacity
539Add for capacity above 50,000 upto 75,000 litres
540Cost of 75,000 litres capacity
541Add for capacity above 75,000 upto 1,00,000 litres
542Cost of 1,00,000 litres capacity
543Add for capacity above 1,00,000 upto 1,50,000 litres
544Cost of 1,50,000 litres capacity
545Add for capacity above 1,50,000 upto 2,00,000 litres
546Cost of 2,00,000 litres capacity
547Add for capacity above 2,00,000 upto 3,00,000 litres
548Cost of 3,00,000 litres capacity
549Add for capacity above 3,00,000 upto 5,00,000 litres
550Cost of 5,00,000 litres capacity
551Add for capacity above 5,00,000 upto 10,00,000 litres
552Cost of 10,00,000 litres capacity
553Addforcapacityabove10,00,000upto15,00,000 litres
554Cost of 15,00,000 litres capacity
555Add for capacity above 15,00,000 litres
556Note: 10% shall be added over the cost of GSR for sump where over head pump house is proposed.
557M1032 UnconventionalWater Treatment Plant
558Designing (aesthetically), providing and constructinghigh rate UnconventionalWaterTreatmentPlant i.e. Simplified Water Treatment Plant consisting of Civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti-termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, Acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub-worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyEngineer-in-charge (turn-key job) works.
559Aeration fountain
560Inlet arrangements
561Mixing channel with ventury flume and flow measuring arrangement
562Inlet channel
563Flocculator- Conforming to I.S. 7208-1974 (Type-C) with detention period of 30 minutes
564Tube settlers-Designing, fabricating and constructing Tube Settlers with square or any other shaped tube like Circular, Cheveron, Hexagonal etc .having proven performance
565Rapid sand gravity filters - All valve shall be glandless.
566Filter house
567Chemical house
568Alum tanks- 2Nos. with mixing, carrying and dosing arrangements with piping.
569100 kg chlorine cylender for capacity upto 5MLD and Chlorine tonner for capacity above 5 MLD.
570TCL solution tank with mixing, carrying and dosing arrangement with piping.
571Bypass arrangement
572External and internal electrification
573Laboratory equipments
574Wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2/m under head of 12m at under drain.
575Wash water pumps with 100% standby
576Air blowers capable of delivering 600 LMP per square metre of free air of filter area at 0.4 Kg / sqcm at the under drains (100 % standby).Air blowers shall be adopted for WTP having capacity more than 3 MLD only. Below 3 MLD capacity, Air blowers shall not be adopted.
577Pure water sump of capacity equal to 1 hourpumping capacity.
578Pure water pump house over the sump / by the side of sump.
579Drainage arrangements
580Alum store
581Sanitary block with necessary water supply and drainage arrangements and internalWBM roads.
582These rates are applicable for seismic zones 2, 3 and 4.
583Rates given below are inclusive of uplift pressure if any and dewatering during the entire work.
584All RCC structures shall be constructed in M-250. Structures in contact with water shall be in M-300.
585Unconventional Treatment Plants less than 1 MLD capacity shall not be constructed.
586All the Structural Steel Works / Fabrications are to be provided with application of Hot Dip Zinc coating according to specification as per IS 4759:1996 (Reafirmed 2006).
587Note: Conditions from Sr. No. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants.
588Unconventional Water Treatment Plant
589Fixed cost for 1 MLD
590Add for capacity above 1 MLD upto 2 MLD
591Cost of 2 MLD treatment plant
592Add for capacity above 2 MLD upto 3 MLD
593Cost of 3 MLD treatment plant
594M1033 ConventionalWater Treatment Plant
595Designing (aesthetically), providingconstructingandcommissioningConventionalWaterTreatmentPlantconsistingofallCivil, MechanicalandElectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel,mechanicalandelectricalcomponentsofvarioussub-worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyEngineer-in-charge (turn-key job).
596Aeration Fountain- Plan are a not less than 0.625 square metre per MLD
597Ventury Flume - With necessary devices, consisting of simple mechanical indicator. (Pedestal type gauge)
598Flash Mixer-Rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec -1, vane mixer type conforming to I.S. 7090 of 1985.
599Flocculator – Conforming to I.S.7208-1974 (Type-C) with detention period of 30 minutes.
600Clarifier - Horizontal flow circular tank, detention period 2-5 hours, overflow rate 30 cubic metre per square metre per day (to be specified), Weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to I.S. No. 10313-1982.
601Rapid Sand Filter sand Filter House-Filter designed for filteration rate of 5,000 litres per square metre per hour, minimum 2 beds for plant upto 10 MLD, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width.
602FilterSand-Effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75M, free board 50cm, gravel 0.45M in depth, sand and gravel conforming to I.S. 8491 (i)-77, back wash by air wash, stand ard appurtenances (to be specified), rate of flow controller, filter gauge, sand expansion gauge, etc.
603Wash Water Tank-Capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more.
604Wash Water Pumps- Capacity to fill water tank in 1 hour with 100% standby.
605Air Blowers-Capable of delivering 600 LMP per square metre of free air, of filter area at 0.4kg / sqcm at the under drains (100% standby).
606Chemical House in Two Storeys
607Ground floor to accommodate 7 days" alum requirement and sundry storage.
608First floor to accommodate alum and lime tanks.etc.
609Solution tanks-Minimum 3 tanks (one for preparation, second for dosing and third as standby), each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30M, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device (constant head device, strength of solution upto 10% only) conforming to I.S. 9222 Part-I 1979.
610Pure Water Sump and Sump House.
611Capacity of sump – One hour of designed flow.
612Pump House- Pump house of required size over the sump or by the side.
613Store House-Suitable for alum storage of three months" requirement in monsoon with 10% extra capacity for other sundry articles.
614Vacuum feed type Chlorinators- Make tobe approved by MJP.
615Conforming to I.S. 10533 - A Part-II 1983
616Rate for withdrawal
617Temperature Kg. of Chlorine discharge Degree "C" per day (Cylinders)
61845 67Tonnes
61910 6.359.50 110
62015 10.75 16.10130
62120 14.50 21.24254
62227&Above18.70 28.12315
623Chlorinator equipment and container room to conform to I.S. 10553 Part-I 1983.
624100% standby shall be provided.
625By pass arrangements - C.I. or M.S. pipes.
626Disposal of waste from WTP: Safe disposal arrangement to near by Nala including cost of pipe
627For WTP of Capacity 30 MLD and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary,rising main etc complete
628Drainage arrangements – RCC pipes up to plot boundary.
629Electrical installation – Both internal and external including entire plant area.
630Laboratory equipment –As per requirement (to be specified during tendering).
631Sanitary blocks – Carpet area -15 square metre minimum upto 25 Mld and 25 square metre above 25 Mld.
632Administrative block and internal road-To accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and WBM road to connect all units from main gate of plot.
633Rates given below are inclusive of up lift pressure if any and dewatering during entire work.
634All pipes condutes channels with20%overloading
635These rates are applicable for seismic zones 2, 3 and 4.
636All RCC structures shall be constructed in M-300.
637Note: Conditions from Sr. No. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants (proposed).
638Conventional Water Treatment Plant
639Above3 MLD to Upto 5 MLD
640Cost of 5 MLD treatment plant
641Add for capacity above 5MLD upto 10 MLD
642Cost of 10 MLD treatment plant
643Add for capacity above 10 MLD upto20 MLD
644Cost of 20 MLD treatment plant
645Add for capacity above 20 MLD upto 50 MLD
646Cost of 50 MLD treatment plant
647Add for capacityabove 50 MLD upto 100 MLD
648Cost of 100 MLD treatment plant
649Add for capacity above 100 MLD
650M1034 GPT/HYGPT :Drilling by Rotary drill machine of size 300mm & 400mm dia with T.C. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of E/I (Basic rates)
651300 mm dia for GPT
652400 mm dia for HYGPT
653M1035 HYDT : Cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site (Basic rates)
654From 0-50 meter
655From 51-125 meter
656M1037 DT :Basic rates for 125/115 mm dia Drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of Engineer Incharge (Basic rates)
657Drillig upto 30 mtr Depth below G. L. in Rural Area
658Drilling beyond 31 mtr upto 60 mtr below G. L. in Rural Area
659M1038 Trenchless
660Installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation ,shoring / strutting etc manual shielded excation ,lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering -in - charge all complete exept the cost of the pipe average cover of 1.5 depth below GI ( upto 100 meter installation length )
661from 900 mm to 1000 mm dia
662In Soft soil
663In Hard soil
664In sandy Soil
665In Stone Soil
666from 1000 mm to 1200 mm dia
667In Soft soil
668In Hard soil
669In sandy Soil
670In Stone Soil
671Above 1200 mm to 1500 mm dia
672In Soft soil
673In Hard soil
674In sandy Soil
675In Stone Soil
676Installation of product pipe by Auger Boring methodincluding making of entry and exit pits all related civil works like excavation ,shoring/strutting etc shielded excavation ,through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering -in - charge all complete exept the cost of the pipe average cover of 1.5 depth below GI ( upto 100 meter installation length )
677upto 300 mm dia
678In Soft soil
679In Hard soil
680In sandy Soil
681In Stone Soil
682Above300 mm to 450 mm dia
683In Soft soil
684In Hard soil
685In sandy Soil
686In Stone Soil
687Above 450 mm to 600 mm dia
688In Soft soil
689In Hard soil
690In sandy Soil
691In Stone Soil
692Above 600 mm to 900 mm dia
693In Soft soil
694In Hard soil
695In sandy Soil
696In Stone Soil
697Installation of product pipe by Guided Auger Boring methodincluding making of entry and exit pits all related civil works like excavation ,shoring/strutting etc shielded excavation ,through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering -in - charge all complete exept the cost of the pipe average cover of 1.5 depth below GI ( upto 100 meter installation length )
698upto 300 mm dia
699In Soft soil
700In Hard soil
701In sandy Soil
702In Stone Soil
703Above300 mm to 450 mm dia
704In Soft soil
705In Hard soil
706In sandy Soil
707In Stone Soil
708Above 450 mm to 600 mm dia
709In Soft soil
710In Hard soil
711In sandy Soil
712In Stone Soil
713Above 600 mm to 900 mm dia
714In Soft soil
715In Hard soil
716In sandy Soil
717In Stone Soil
718M1039 Providing and Supplying ISI Mark CI/ D/F reflux valves( Non return Valves ) of following dia inspection charges unloading from railway wagon ,loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per IS 5312 Part I (1984)
719Without byepass arrangement - PN-1
72050 MM
72165 MM
72280 MM
723100 MM
724125 MM
725150 MM
726200 MM
727250 MM
728300 MM
729350 MM
730400 MM
731450 MM
732500 MM
733600 MM
734700 MM
735750 MM
736800 MM
737900 MM
7381000 MM
7391100 MM
7401200 MM
741With byepass arrangement - PN-1
74250 MM
74365 MM
74480 MM
745100 MM
746125 MM
747150 MM
748200 MM
749250 MM
750300 MM
751350 MM
752400 MM
753450 MM
754500 MM
755600 MM
756700 MM
757750 MM
758800 MM
759900 MM
7601000 MM
7611100 MM
7621200 MM
763Without byepass arrangement - PN-1.6
76450 MM
76565 MM
76680 MM
767100 MM
768125 MM
769150 MM
770200 MM
771250 MM
772300 MM
773350 MM
774400 MM
775450 MM
776500 MM
777600 MM
778With byepass arrangement - PN-1.6
77950 MM
78065 MM
78180 MM
782100 MM
783125 MM
784150 MM
785200 MM
786250 MM
787300 MM
788350 MM
789400 MM
790450 MM
791500 MM
792600 MM
793Providing double flange sluice valve ( Size 50 mm to 1200 mm ) confirming for IS - 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete .
794With byepass arrangement - PN-1
79550 MM
79665 MM
79780 MM
798100 MM
799125 MM
800150 MM
801200 MM
802250 MM
803300 MM
804350 MM
805400 MM
806450 MM
807500 MM
808600 MM
809700MM
810750 MM
811800 MM
812900 MM
8131000 MM
8141100 MM
8151200MM
816Without byepass arrangement - PN-1
81750 MM
81865 MM
81980 MM
820100 MM
821125 MM
822150 MM
823200 MM
824250 MM
825300 MM
826350 MM
827400 MM
828450 MM
829500 MM
830600 MM
831700MM
832750 MM
833800 MM
834900 MM
8351000 MM
8361100 MM
8371200MM
838Providing double flange sluice valve confirming for IS - 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete FOR Rateincluding all taxes . .
839Without byepass arrangement - PN-1.6
84050 MM
84165 MM
84280 MM
843100 MM
844125 MM
845150 MM
846200 MM
847250 MM
848300 MM
849350 MM
850400 MM
851450 MM
852500 MM
853600 MM
854700MM
855750 MM
856800 MM
857900 MM
8581000 MM
8591100 MM
8601200MM
861With byepass arrangement - PN-1.6
86250 MM
86365 MM
86480 MM
865100 MM
866125 MM
867150 MM
868200 MM
869250 MM
870300 MM
871350 MM
872400 MM
873450 MM
874500 MM
875600 MM
876M1040 Design and Supply of V -wire screen laterals suitable for infiltration Galleryas per site condition and detail provided End connection suitable flange excluding taxes and transportation .
877Dia - 06 inch ( 150 mm )
878ID - 153 mm OD -167 mm
879Screen thickness - 07 mm
880Slot - 1.00 mm
881MOC - LowCarbon Galvenised steel
882Length - 5 mtr.
883Dia - 08 inch ( 200 mm )
884ID - 205 mm OD -221mm
885Screen thickness - 08 mm
886Slot - 1.00 mm
887MOC - LowCarbon Galvenised steel
888Length - 5 mtr.
889Dia - 10 inch ( 250 mm )
890ID - 256 mm OD -276mm
891Screen thickness - 10 mm
892Slot - 1.00 mm
893MOC - LowCarbon Galvenised steel
894Length - 5 mtr.
895Dia - 12 inch ( 300 mm )
896ID - 306 mm OD -326 mm
897Screen thickness - 10 mm
898Slot - 1.00 mm
899MOC - LowCarbon Galvenised steel
900Length - 5 mtr.
901Dia - 14 inch ( 350 mm )
902ID - 338 mm OD -363 mm
903Screen thickness - 12.5 mm
904Slot - 1.00 mm
905MOC - LowCarbon Galvenised steel
906Length - 5 mtr.
907M1041 Supplying all materials, labours, equipments for lowering 125mm dia blue UPVC casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site(Basic Rate).
908M1042 Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction E/I (Basic Rate).
909M1043 Supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of E/I (Basic Rate).
910M1044 Supplying labour and equipments including 125mm dia G.I. Cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction E/I (The cap will be the property of department) (Basic Rate).
911M1045 Supplying all materials, labours, equipments for constructing P.C.C. (1:2:4) circular platform around drilled tube well including 12mm thick cement plaster (1:4) with neat cement punning over exposed surface as per UNICEF design, etc. all complete including carriage of materials (Basic Rate).
912M1046 Supplying all materials, labours and equipments for constructing P.C.C. (1:2:4) drain as per UNICEF design etc. all complete including carriage of materials (Basic Rate).
913M1047 Supplying extra Deep well Hand Pump Complete sets with Cylinder Assembly & Connecting Rod (12 Pcs) as per IS : 15500 Part-2/2004(Basic Rate).
914M1048 Supply of 200mm dia x 3.00m long UPVC casing pipe conferming to IS : 12818: 2016 (CML No. 5543459) latest revision including carrigae(Basic Rate).
915M1049 Supply of 200mm dia ribbed Screen pipe conferming toIS : 12818: 2016 (CML No. 5543459) latest revision including carrigae(Basic Rate).
916M1050 Supply of 125mm dia ribbed Screen pipe conferming toIS : 12818: 2016 (CML No. 5543459) latest revision including carrigae(Basic Rate).
917M1051 Supplying all tools, equipments and labour and lowering 32 mm dia medium quality G.I. pipe in drilled tube well in 3 Mtrs. Length all complete as per dirction E/I including carriage of materials (Basic Rate).
918M1052 Supplying all tools, Labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of E/I including carriage of materials (Basic Rate).
919M1053 Supplying all materials, labours and fixing India mark II Hand Pump with all accessories all complete job as per direction of E/I including carriage of materials(Basic Rate).
920M1054 Design, Supply, Installation testing & Commissioning of packaged water treatment plants (Unconventional type) of different capacity with (20 hours operation) comprising of lamella clarifier, Static Mixture Flocculation Tank (SMET), Multi grade filter (MGF) with best quality filter media, Lime/ coagulant/polymer dosing system hypo chloride dosing system, Raw water feed pump/clear water transfer pump (either or), sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with MCB panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer/ authorized distribution / authorized dealer conforming to relevant IS codes and certified by ISO-9001-2008 & 14001, It also include cost of civil foundation, including clarified water tank internal connecting pipe line from Raw Water inlet to CWR and applying internal epoxy paint on the supply equipment All the prices are exclusive of GST, Allied structure/items which are site specific such as external electrification, approach road, foot Bridge, cofferdam, compound wall, SCADA and automation, CWR pumps etc are to be considered extra.
9210.2 MLD
9220.3 MLD
9230.4 MLD
9240.5 MLD
9250.6 MLD
926M1055 PUMPS
927Supplying100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V+10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.
928Submersible Pump set 100 mm dia (with Polypropylene/ Noryl Impeller) up to 20 stages
9291 H.P.
9301.5HP
9312 HP
9322.5 HP
9333.0 HP
9344.0 HP
9355.0 HP
936Supply rate should be increased by Rs 200/- per stage for pump with more than 20 stages
937Submersible Pump 150 mm dia (with Bronze impeller) up to 8 stages
9381.5 HP
9392.0 HP
9403.0 HP
9414.0 HP
9425.0 HP
9436.0 HP
9447.5 HP
945Supply rate should be increased by Rs 600/- per stage for pump with more than 8 stages
946Submersible Pump 150 mm dia (with Bronze Impeller) up to 12 stages
9478.0 HP
9489.0 HP
94910.0 HP
95011.0 HP
95112.5 HP
95215.0 HP
953Supply rate should be increased by Rs 600/- per stage for pump with more than 12 stages
954Submersible Pump 150 mm dia (with Bronze Impeller) up to 20 stages
95517.5 HP
95620.0 HP
95725 HP
9581) Supply rate should be increased by Rs 600/- per stage for pump with more than 20 stages for Bore well only.
959For other use 200 mm dia pump shall be preferred over 150 mm dia with more than 20 stage pump.
9602) For 150 mm dia energy efficient pumps add as below
961a. up to 8 stages :- 3% on supply rate
962b. up to 12 stages :- 4% on supply rate
963c. up to 15 stages :- 5% on supply rate
964M1056 PRESSURE GAUGE
965Providing fabricating, testing and commisioning pressure vessel fabricating in M.S plate on providing foundation including epoxy paint
966Pressure gauge (100 mm dia)
967Pressure gauge (150 mm dia)
968Vacuum / Combination gauge
969SupplyingVacuum Gauge/ Combination gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. pipe.
970Vacuum / Combination gauge – 100 mm dia
971Vacuum / Combination gauge – 150 mm dia
972M1057 Lifting Equipment
973Chain pulley Block
974Supplyingtriple spur gear type chain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark.
9751 Tonne Capacity
9762 Tonne Capacity
9773 Tonne Capacity
978Hand operated Circular or Rectangular Travelling Crane (Single Girder)
979SupplyingSingle Girder Hand Operated Circular/ Rectangular Travelling Crane with 6 m lift complete with chain pulley block ISI marked and travelling trolley both tested for 50% overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete.
9803 Tonne Capacity
981Up to 5 m span
982Above 5 m up to 6 m span
983Above 6 m up to 8 m span
9845 Tonne Capacity
985Up to 5 m span
986Above 5 m up to 6 m span
987Above 6 m up to 8 m span
988Above 8 m up to 10 m span
989Electric Operated Circular or Rectangular Travelling Crane (Single Girder)
990Supplying single girder Electrically Operated Rectangular Over head Travelling Crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendant control block.
9915 Tonne Capacity
992Above 6 m up to 8 m span
993Above 8 m up to 10 m span
9947.5 Tonne Capacity
995Above 6 m upto 8 m span
996Above 8 m up to 10 m span
99710 Tonne Capacity
998Above 6 m up to 8 m span
999Above 8 m up to 10 m span
1000Square Bar / Rail
1001Providing, erecting and fixing square bar of EN 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and “J” bolts.
100250 X 50 mm (EN 8)
100340 X 40 mm (EN 8)
1004M1058 Lightening Arrester, AB Switch, Insulators
1005Lightening Arrestor
1006Supplying, erecting approved make thyrite type Lightening Arrestor suitable for H.T. supply with necessary ancillary material complete on provided cross arm and connected to overhead line.
1007Suitable for 11 kV Supply, Distribution class
1008Suitable for 22 kV Supply, Distribution class
1009Suitable for 33 kV Supply, Station class
1010Disc Insulator
1011Supplying, erecting porcelain Disc Type Insulators with hardware fittings suitable for H.T. overhead line complete erected with nuts and bolts on provided cross arm
1012Suitable for 11KV line
1013Suitable for 33KV line
1014Pin Insulator
1015Supplying, erecting porcelain Pin Type Insulators with hardware fittings suitable for H.T. overhead line complete erected with nuts and bolts on provided cross arm
1016Suitable for 11KV line
1017Suitable for 33KV line
1018Air break switch without Earth switch
1019Supplying, erecting approved make H.T. outdoor type gang operated air break triple pole switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground with necessary clamps
1020Suitable for 11KV line
1021Rocking / Tilting type
1022Rotating type
1023Suitable for 33KV line
1024Rocking / Tilting type
1025Rotating type
1026Air break switch with Earth switch
1027Supplying, erecting approved make H.T. outdoor type gang operated air break triple pole switch with earth switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground with necessary clamps
1028Suitable for 11KV line
1029Rotating type
1030Suitable for 33KV line
1031Rotating type
1032Drop out Fuse (channel mounted)
1033Supplying, erecting approved make out door type Drop out fuse channel type with insulator complete with fuse holders fuse barrel with metal fittings, fuse element, with working currentup to 50 Amp, capacity completeerected on provided cross arm, each set comprising 3 units
1034Suitable for 11 KV line
1035Suitable for 33 KV line
1036Horn gap fuse (channel mounted)
1037Supplying, erecting approved make out door type Horn gap type fuse with insulator, fuse element, with working current up to 50 Amp, capacity complete erected on provided cross arm, each set comprising 3 units
1038Suitable for 11 KV line
1039Suitable for 33 KV line
1040M1059 TRANSFORMER
1041Power Transformer (with off load Tap changer) Any ISI Mark
1042Supplyingoutdoor type copper wound transformer continuously rated for 3Ph, 50 Hz, at full load and temp. rise not exceeding 450 C by thermometer in oil and 500 C by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provideseparateearthing. The Transformer shall have power terminal arrangement, bushing/ cable end box on HT side and cable end box on LT side. 2 Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. Transformer shall be latest manufacturing standards as per amended IS specifications and the load & No load losses shall be limited to the values given below or as per IS or Norms issued by SEB which ever are lower-
10431.      Oil conservator with filling hole with cap and plain oil level gauge.
10442.      Silica gel dehydrating breather charged with silica gel.
10453.      Oil drain valve
10464.      Oil filter valve
10475.      Lifting eyes/ hooks
10486.      Two earthing terminals
10497.      Diagram and rating plate
10508.      Air vent
10519.      Explosion vent
105210.   100mm dia thermo meter with thermometer pocket
105311.   Four bi directional plain roller.
1054Power Transformer 11000/433 volts With off load Tap Changer – 12.5% to +2.5% in steps of 2.5% as per BIS Level-2.
105563 KVA ( No load loss 180w and load loss 1235w)
1056100 KVA (No load loss 260w and load loss 1760w)
1057160KVA (No load loss 260w and load loss 1760w)
1058200KVA(No load loss 500w and load loss3000w)
1059250KVAA(No load loss 550w and load loss3600w)
1060315KVA (No load loss 580w and load loss 4200w)
1061400 KVA (No load loss 715w and load loss 5000w)
1062500 KVA (No load loss 850w and load loss 5800w)
1063630 KVA (No load loss 1000w and load loss 7000w)
1064750 KVA (No load loss 1500w and load loss 8000w)
1065Power Transformer (with on load Tap changer)
1066Supplyingoutdoor type copper wound transformer continuously rated for 3Ph, 50 Hz, at full load and temp. rise not exceeding 450 C by thermometer in oil and 500 C by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provideseparateearthing. The Transformer shall have power terminal arrangement, bushing/ cable end box on HT side and cable end box on LT side. 2Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. The OLTC should be suitable for minimum 50 operations per day. Transformer shall be latest manufacturing standards as per amended IS specifications and the load & No load losses shall be limited to the values given below or as per IS or Norms issued by SEB which ever are lower-
10671.      Oil conservator with filling hole with cap and plain oil level gauge.
10682.      Silica gel dehydrating breather charged with silica gel.
10693.      Oil drain valve
10704.      Oil filter valve
10715.      Lifting eyes/ hooks
10726.      Two earthing terminals
10737.      Diagram and rating plate
10748.      Air vent
10759.      Explosion vent
107610.   100mm dia thermo meter with thermometer pocket
107711.   Four bi directional plain roller.
107812.   Buchholz relay
107913.   Resistance Temp. detector
108014.   Marshalling box
108115.   Automatic Voltage Regulator (AVR)
108216.   Remote Tap Changing Controller (RTCC)
1083Transformer 11000/433 volts Withon load Tap Changer – 15% to +5% in steps of 1.25% with RTCC, AVR and marshalling box and other specification as per BIS Level-2.
1084750 KVA
10851000 KVA
10861250 KVA
10871600 KVA
10882000 KVA
1089M1060 Motors
1090Foot Mounted Motors TEFC 1500 RPM
1091SupplyingFoot Mounted TEFC 1500 RPM, squirrel cage induction motor, conforming to IS 325 having continuous rating suitable for operation at 415 volts +/-10%, 3 Phase, 50 HZ +/-3% with “F” class insulation temperature rise limited to class “B” insulation. Motors conform to IS-12615 with efficiency level IE3 and provided with enclosure protection class IP-55.
109215 KW (20 HP)
109318.5 KW ( 25 HP)
109422 KW ( 30 HP)
109530 KW ( 40 HP)
109637 KW ( 50 HP)
109745 KW ( 60 HP)
109855 KW ( 75 HP)
109975 KW ( 100 HP)
110090 KW ( 120 HP)
1101110 KW ( 150 HP)
1102132KW(180HP)
1103160KW( 215 HP)
1104250KW (335 HP)
1105Foot Mounted Motor TEFC 1500 RPM
11060.75 KW(1HP)
11071.1   KW ( 1.5 HP)
11081.5 KW ( 2 HP)
11092.2 KW ( 3 HP)
11103.7 KW ( 5 HP)
11115.5 KW ( 7.5 HP)
11127.5 KW ( 10 HP)
11139.3 KW ( 12.5 HP)
111411 KW ( 15 HP)
1115M1061 Aluminium Cable
1116CABLE
1117Aluminium conductor three core, XLPE / PVC insulated & armoured cable .
1118SupplyingXLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner.
11193 core 2.5 sq mm
11203 core 4 sq mm
11213 core 6 sq mm
11223 core 10 sq mm
11233 core 16 sq mm
11243 core 25 sq mm
11253 core 35 sq mm
11263 core 50 sq mm
11273 core 70 sq mm
11283 core 95 sq mm
11293 core 120 sq mm
11303 core 150 sq mm
11313 core 185 sq mm
11323 core 240 sq mm
11333 core 300 sq mm
11343 core 400 sq mm
1135Aluminium conductor 3.5 core, XLPE / PVC insulated & unarmoured cable
1136SupplyingXLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark Three and half core, stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, completein an approved manner.
11373.5 core 25 sq mm
11383.5 core 35 sq mm
11393.5 core 50 sq mm
11403.5 core 70 sq mm
11413.5 core 95 sq mm
11423.5 core 120 sq mm
11433.5 core 150 sq mm
11443.5 core 185 sq mm
11453.5 core 240 sq mm
11463.5 core 300 sq mm
11473.5 core 400 sq mm
1148HT Aluminium three core 3.3 KVE cable XLPE insulated
1149Supplying HT Aluminium three core cable XLPE insulated ,insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape ,galvanised steel flat strip armoured,and overall PVC sheathed cable conforming to IS :7098 /II/85 with latest amendments
11503 core 35 sq mm
11513 core 50 sq mm
11523 core 70 sq mm
11533 core 95 sq mm
11543 core 120 sq mm
11553 core150sq mm
11563 core 185 sq mm
11573 core 240sq mm
11583 core 300 sq mm
11593 core 400 sq mm
1160HT Aluminium three core 6.6 KV(UE)/11KV Ecable XLPE insulated
1161Supplying HT Aluminium three core cable XLPE insulated ,insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape ,galvanised steel flat strip armoured,and overall PVC sheathed cable conforming to IS :7098 /II/85 with latest amendments
11623 core 35 sq mm
11633 core 50 sq mm
11643 core 70 sq mm
11653 core 95 sq mm
11663 core 120 sq mm
11673 core150sq mm
11683 core 185 sq mm
11693 core 240sq mm
11703 core 300 sq mm
11713 core 400 sq mm
1172HT Aluminium three core 11KV(UE) cable XLPE insulated
1173Supplying HT Aluminium three core cable XLPE insulated ,insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape ,galvanised steel flat strip armoured,and overall PVC sheathed cable conforming to IS :7098 /II/85 with latest amendments
11743 core 35 sq mm
11753 core 50 sq mm
11763 core 70 sq mm
11773 core 95 sq mm
11783 core 120 sq mm
11793 core150sq mm
11803 core 185 sq mm
11813 core 240sq mm
11823 core 300 sq mm
11833 core 400 sq mm
1184Aluminium conductor three core, XLPE / PVC insulated & unarmoured cable .
1185SupplyingXLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark Three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner.
11863 core 4 sq mm
11873 core 6 sq mm
11883 core 10 sq mm
11893 core 16 sq mm
11903 core 25 sq mm
11913 core 35 sq mm
11923 core 50 sq mm
11933 core 70 sq mm
11943 core 95 sq mm
11953 core 120 sq mm
11963 core 150 sq mm
11973 core 185 sq mm
11983 core 240 sq mm
11993 core 300 sq mm
12003 core 400 sq mm
1201M1062 Copper Cable
1202CABLE
12033 Core PVC insulated, PVC sheathed copper conductor flat submersible cable .
1204Supplying , Flat flexible submersible cable with, copper conductor, PVC insulated, and PVC sheathed .
12053 core 1.5 sq mm
12063 core 2.5 sq mm
12073 core 4 sq mm
12083 core 6 sq mm
12093 core 10 sq mm
12103 core 16 sq mm
12113 core 25 sq mm
12123 core 35 sq mm
1213Copper conductor three core, XLPE / PVC insulated & unarmoured cable .
1214SupplyingXLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark Three core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner.
12153  core 1.5 sq mm
12163  core 2.5 sq mm
12173  core 4 sq mm
12183  core 6 sq mm
12193  core 10 sq mm
12203  core 16 sq mm
12213 core 25 sq mm
12223 core 35 sq mm
12233 core 50 sq mm
12243 core 70 sq mm
12253 core 95 sq mm
1226Copper conductor 3.5 core, XLPE / PVC insulated & armoured cable .
1227SupplyingXLPE / PVC insulated, armoured cable 1100 V grade with ISI mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, completein an approved manner.
12283.5 core 1.5 sq mm
12293.5 core 2.5 sq mm
12303.5 core 4 sq mm
12313.5 core 6 sq mm
12323.5 core 10 sq mm
12333.5 core 16 sq mm
12343.5 core 25 sq mm
12353.5 core 35 sq mm
12363.5 core 50 sq mm
12373 .5 core 70 sq mm
12383.5 core 95 sq mm
12393.5 core 120 sq mm
12403 .5 core150sq mm
12413.5 core 185 sq mm
12423.5 core 240sq mm
12433.5 core 300 sq mm
12443.5 core 400 sq mm
1245copper conductor 3.5 core XLPE/PVCunarmoured
1246SupplyingXLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner.
12473.5core 25 sq mm
12483.5core 35 sq mm
12493.5 core 50 sq mm
12503.5 core 70 sq mm
12513.5 core 95 sq mm
12523.5 core 120 sq mm
12533.5 core150sq mm
12543.5 core 185 sq mm
12553.5 core 240sq mm
12563.5 core 300 sq mm
12573.5 core 400 sq mm
1258Copper conductor three core, XLPE / PVC insulated & armoured cable .
1259SupplyingXLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Three core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner.
12603  core 1.5 sq mm
12613 core 2.5 sq mm
12623 core 4 sq mm
12633 core 6 sq mm
12643 core 10 sq mm
12653 core 16 sq mm
12663 core 25 sq mm
12673 core 35 sq mm
12683 core 50 sq mm
12693 core 70 sq mm
12703 core 95 sq mm
12713 core 120 sq mm
12723 core 150sq mm
12733core 185 sq mm
12743 core 240 sq mm
12753 core 300 sq mm
12763 core 400 sq mm
1277M1063 FOOT VALVE
1278Foot valve
1279Supplying C.I. foot valve having single leather flap and gunmetal seating. Valve shall be fixed on suction side of pump as per requirement including jointing material and hardware.
1280Flanged type
128150 mm
128265 mm
128380 mm
1284100 mm
1285125 mm
1286150 mm
1287M1064 AirCircuit Breaker
1288ACBbreaking capacity 50kA Thermal Magnetic Manual draw Out type 3 pole
1289630A
1290800A
12911000A
12921250A
12931600A
12942000A
1295M1065 STARTER
1296D.O.L. starter with SS Enclosure with 380/415 Volt coil
12977.5 H.P.
129810 H.P.
1299SupplyingFully automatic star delta starter to operate induction motor working on415v,3phase,50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser
1300F.A.S.D starter
130110.0 H.P.
130215 H.P.
130320 H.P.
130425 H.P.
130535 H.P.
130640 HP
130750 HP
130875 H.P.
1309100 H.P.
1310125 H.P.
1311150 H.P.
1312250 H.P.
1313M1066 Servo Controlled Automatic Voltage Stabilizer
1314Providing, erecting Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user"s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cable should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated ?? Over Voltage / Under Voltage ?? Single Phasing ?? Cut off contactor with electronic output sensing unit
1315Servo Controlled Automatic Voltage Stabiliser(Out put 415 +/-1%)Input 150 to 450 Volt
131620 kVA Air cooled
131725 kVA Air cooled
131830 kVA Air cooled
131940 kVA Air cooled
132050 kVA Oil cooled
132160 kVA Oil cooled
132275 kVA Oil cooled
1323100 kVA Oil cooled
1324125 kVA Oil cooled
1325Servo Controlled Automatic Voltage Stabiliser (Out put 415 +/-1%) Input 280 to 460 Volt
132615 KVA Air cooled
132720 KVA Air cooled
132825 KVA Air cooled
132930 KVA Air cooled
133040 kVA Air cooled
133150KVA Air cooled
133260 KVA Oil cooled
133375KVA Oil cooled
1334100 KVA Oil cooled
1335125 kVA Oil cooled
1336150 KVA oil cooled
1337200KVA oil cooled
1338250KVA oil cooled
1339300 KVA oil cooled
1340400 KVA oil cooled
1341M1067 Termination Kit
1342Providing and errecting IN-DOOR type termination kit, for 3.3kV/ 6.6 kV / 11kV/ 22kV/33kV XLPE Screened 3 core cable
1343IN-DOOR Termination KIT for 3.3kV(E/UE) / 6.6 kV(E) XLPE 3 core cable
134425-50 mm2
134570-120 mm2
1346150-185 mm2
1347240-400 mm2
1348OUT-DOOR Termination KIT for 3.3(E/UE)/6.6 KV(E) XLPE 3 core cable
134925-50 mm2
135070-120 mm2
1351150-185 mm2
1352240-400 mm2
1353Straight through Joint for 3.3KV(E/UE)/ 6.6 KV(E) XLPE 3 core cable
135425-50 mm2
135570-120 mm2
1356150-185 mm2
1357240-300 mm2
1358IN DOOR Termination KIT for 11KV(E) XLPE Screened 3 core cable
135925-50 mm2
136070-120 mm2
1361150-185 mm2
1362240-400 mm2
1363OUT DOOR Termination KIT for 11KV(E) XLPE Screened 3 core cable
136425-50 mm2
136570-120 mm2
1366150-185 mm2
1367240-400 mm2
1368Straight through Joint for 11 KV(E) XLPE Screened 3 core cable
136925-50 mm2
137070-120 mm2
1371150-185 mm2
1372240-300 mm2
1373IN DOOR Termination KIT for 22KV(E) XLPE Screened 3 core cable
137425-50 mm2
137570-120 mm2
1376150-185 mm2
1377240-400 mm2
1378OUT DOOR Termination KIT for 22KV(E) XLPE Screened 3 core cable
137925-50 mm2
138070-120 mm2
1381150-185 mm2
1382240-400 mm2
1383Straight through Joint for 22 KV(E) XLPE Screened 3 core cable
138425-50 mm2
138570-95 mm2
1386120-150 mm2
1387185-240 mm2
1388300-400 mm2
1389IN DOOR Termination KIT for 33KV(E) XLPE Screened 3 core cable
139025-50 mm2
139170-95 mm2
1392120-185 mm2
1393240-400 mm2
1394OUT DOOR Termination KIT for 33 KV(E) XLPE Screened 3 core cable
139525-50 mm2
139670-95 mm2
1397120-185 mm2
1398240-400 mm2
1399Straight through Joint for 33 KV(E) XLPE Screened 3 core cable
140035-70 mm2
140195-150 mm2
1402185-300 mm2
1403400 mm2
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail