Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-05-2022 | BOQ CHANGE | Other | 10-05-2022 |
| Sl. No. | Item Description |
| 1 | General Excavation by mechanical/ manual means in all types of soil including dense soil, discentegrated/ weathered/ including necessary manual excavation for dressing the edges & leveling, all leads and lifts, back filling in layers of 300mm with watering and compaction. Rate to include disposing the excess earth and spreading in layers to the required levels within the site wherever specified, dewatering of both ground and surface water, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, struting, required for keeping earth in position etc,. excavating loose pockets and compacting the same. Note:Authorised working space shall be considered as per IS 1200 (Provision of slopes if required for execution shall not be paid separately). |
| 2 | Upto 1.50 metre from existing Ground Level |
| 3 | Below 1.50 metre upto 3.00 metre |
| 4 | General Excavation by mechanical/ manual means in all types of hard murum including dense soil, discentegrated/ weathered/ including necessary manual excavation for dressing the edges & leveling, all leads and lifts, back filling in layers of 300mm with watering and compaction. Rate to include disposing the excess earth and spreading in layers to the required levels within the site wherever specified, dewatering of both ground and surface water, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, struting, required for keeping earth in position etc,. excavating loose pockets and compacting the same. Note:Authorised working space shall be considered as per IS 1200 (Provision of slopes if required for execution shall not be paid separately). |
| 5 | Upto 1.50 metre from existing Ground Level |
| 6 | Below 1.50 metre upto 3.00 metre |
| 7 | General Excavation by mechanical/ manual means in all types of soft rock including dense soil, discentegrated/ weathered/ including necessary manual excavation for dressing the edges & leveling, all leads and lifts, back filling in layers of 300mm with watering and compaction. Rate to include disposing the excess earth and spreading in layers to the required levels within the site wherever specified, dewatering of both ground and surface water, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, struting, required for keeping earth in position etc,. excavating loose pockets and compacting the same. Note:Authorised working space shall be considered as per IS 1200 (Provision of slopes if required for execution shall not be paid separately). |
| 8 | Upto 1.50 metre from existing Ground Level |
| 9 | Below 1.50 metre upto 3.00 metre |
| 10 | General Excavation by mechanical/ manual means in all types of HARD rock including dense soil, discentegrated/ weathered/ including necessary manual excavation for dressing the edges & leveling, all leads and lifts, back filling in layers of 300mm with watering and compaction. Rate to include disposing the excess earth and spreading in layers to the required levels within the site wherever specified, dewatering of both ground and surface water, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, struting, required for keeping earth in position etc,. excavating loose pockets and compacting the same. Note:Authorised working space shall be considered as per IS 1200 (Provision of slopes if required for execution shall not be paid separately). |
| 11 | Upto 1.50 metre from existing Ground Level |
| 12 | Below 1.50 metre upto 3.00 metre |
| 13 | Filling in plinths etc. wherever specifiedin layers of not exceeding 200 millimetre thick including breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 90 to 95% proctor density at optimum moisture content, all leads and lifts, bailing/ pumping out of water to keep site dry while backfilling; cost shall include conveyance of all materials, labour, royalty, machinery etc. complete as directed (payment for solid measure of the consolidated filling). |
| 14 | With selected earth from excavation |
| 15 | With good earth carried from outside the site premises |
| 16 | Providing and laying in position Stone Metal Hard core using stone aggregates (75-50 millimetre ) and stone dust top compacted thickness of 150millimetresoling with murum cushion of 50mm thick including the cost of murum cushion, Base preparation by Mechanical compaction, usingas directed by the Engineer-in-charge including watering,packing, compaction etc. complete. |
| 17 | Transportation of excess soil not comsumed Outside the Site Boundry upto a lead of 3 kilometres starting from any periphery of the site, using manual, mechanical equipments and machinery (i.e. manual labour, excavators, loaders and dumpers), including double handling of excess materials, disposing-off the excess material to a site approved by the local authority. The item rate should include all the performance and mobility related factors for manpower, mechanical equipments and machinery. |
| 18 | Supplying approved good quality LIGHT WEIGHT filling materialin layers not exceeding 0.20 metre in depth consolidating each deposited layer by mechanical ramming and watering, and leads up to any depth and all lifts at all levels including cost of all labour, transportation etc. complete (compacted thickness will be measured).same above In Toilets, Sunken Slabs and other areas in the building. |
| 19 | Providing Anti termite treatment in accordance with stipulations laid down by IS 6313 - part II by approved agency with minimum of 10 years of guarantee including the cost of chemical,precautionary measures etc.complete along retaining walls only for a width of one meter or as specified by the Architects. For Plinth |
| 20 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-10(1:3:6) of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC withreversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). |
| 21 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-15(1:2:4) of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC withreversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). |
| 22 | Providing and laying in situ/ Ready Mixcement concrete Mix-25of trap/ granite/quartzite/ gneissmetal for Reinforced Cement Concrete workin foundations like raft, strip foundations, grillage andfootings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic ControllerwithSupervisoryControl and Data Acquisition enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 23 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap/ granite/quartzite/ gneiss metal for Reinforced cement concretePlinth Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLCReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). |
| 24 | Providing and laying Cast in situ/ Ready Mix cement concrete M-35 of trap/ granite/quartzite/ gneiss metal for Reinforced cement concreteBeams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). |
| 25 | FIRST SLAB BEAMS |
| 26 | SECOND SLAB BEAMS |
| 27 | THIRD SLAB BEAMS |
| 28 | FOURTH SLAB BEAMS |
| 29 | ABOVE FOURTH SLAB |
| 30 | Providing and laying Cast in situ/ Ready Mix cement concrete M-35 of trap/ granite/quartzite/ gneiss metal for Reinforced cement concreteP.T. Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC withReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). |
| 31 | FIRST SLAB BEAMS |
| 32 | SECOND SLAB BEAMS |
| 33 | THIRD SLAB BEAMS |
| 34 | FOURTH SLAB BEAMS |
| 35 | Providing and laying cast in situ/ Ready Mix cement concrete M-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concretecolumns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC withReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). |
| 36 | UPTO PLINTH |
| 37 | PLINTH TO FIRST SLAB |
| 38 | Providing and laying cast in situ/ Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concretecolumns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC withReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). |
| 39 | FIRST TO SECOND SLAB |
| 40 | SECOND TO THIRD SLAB |
| 41 | TIRD TO FOURTH SLAB |
| 42 | ABOVE FOURTH SLAB |
| 43 | Providing and laying Cast in situ/ Ready Mix cement concrete M-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concreteSlabs and Landingsas per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC withReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 44 | FIRST SLAB |
| 45 | SECOND SLAB |
| 46 | THIRD SLAB |
| 47 | FOURTH SLAB |
| 48 | ABOVE FOURTH SLAB |
| 49 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concretePardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC withReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 50 | UPTO PLINTH |
| 51 | PLINTH TO FIRST SLAB |
| 52 | FIRST TO SECOND SLAB |
| 53 | SECOND TO THIRD SLAB |
| 54 | TIRD TO FOURTH SLAB |
| 55 | ABOVE FOURTH SLAB |
| 56 | Providing and laying Cast in situ/ Ready Mix cement concrete inM-35 of trap / quartzite /granite /gneiss metal for Reinforced cement concreteWaist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based PLC withReversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). |
| 57 | FIRST SLAB |
| 58 | SECOND SLAB |
| 59 | THIRD SLAB |
| 60 | FOURTH SLAB |
| 61 | Providing and laying Cast in situ/ Ready Mix cement concrete M-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concreteChajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 62 | PLINTH TO FIRST SLAB |
| 63 | FIRST TO SECOND SLAB |
| 64 | SECOND TO THIRD SLAB |
| 65 | THIRD TO FOURTH SLAB |
| 66 | Providing and fixing in position Thermo Mechanically Treated(TMT) FE -500 bar reinforcement of various diameters for Reinforced cement concretepile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 67 | FIRST SLAB |
| 68 | SECOND SLAB |
| 69 | THIRD SLAB |
| 70 | FOURTH SLAB |
| 71 | ABOVE FOURTH SLAB |
| 72 | Providing & Execution of Post Tensioning works Beamsincluding decoiling the strands, cutting to the required lengths, supplying and laying of HT strands, sheathing(GI corrugated ducts 80mm x 20 mm 0.30 mm thick) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages including the supply of stressing anchorages suitable for 5-5 & 5-4 Tendons, grout vents, making dead end anchorages including flowering the strands, fixing tendon support bars, supervising the fixing of anti bursting reinforcement, stressing the cables, end trimming, grouting the cables with cement and admixtures, with required Plant & Machineries, tools and tackles, consumables etc., including obtaining approval from client/consultant for the work done as per the requirement of Engineer-In charge at site |
| 73 | FIRST SLAB BEAMS |
| 74 | SECOND SLABBEAMS |
| 75 | THIRD SLAB BEAMS |
| 76 | FOURTH SLAB BEAMS |
| 77 | Providing, Supplying and Mixing in the preparation of Cement Concrete, Cement Mortars and PCC, integral liquid waterproofing admixtures of Pidilite - Dr. FIXIT - PIDIPROOF LW or equivalent as per the dosage and the method of application as recommended by the manufacturer at all levels with all leads and lifts etc. complete. |
| 78 | Providing fly ash brick masonary with conventional /IndianStandardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, strikingjoints, racking out joints, watering and scaffolding complete. |
| 79 | Providing second class Burnt Brick masonry with conventional / I. S. type bricks in cement mortar 1:6 in foundations & plinth including striking joints, raking out joints, watering and scaffolding complete. |
| 80 | Providing fly ash brick masonary with conventional / I.S. type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. |
| 81 | GROUND FLOOR |
| 82 | FIRST FLOOR |
| 83 | SECOND FLOOR |
| 84 | THIRD FLOOR |
| 85 | TOP TERRACE |
| 86 | Providing second class Burnt Brick masonry with conventional / I. S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding comple |
| 87 | GROUND FLOOR |
| 88 | FIRST FLOOR |
| 89 | SECOND FLOOR |
| 90 | THIRD FLOOR |
| 91 | Providing Autoclaved Areated Concrete block masonary of Ecolite or equivalent make conforming to IS:2185(Part 3)- 1984 in extra fine jointing mortor of fixoblock of UltraTech or equivalent in Half brick thick wallincluding striking joints, racking out joints watering and scaffolding etc. complete.(150 millimetrethick) |
| 92 | GROUND FLOOR |
| 93 | FIRST FLOOR |
| 94 | SECOND FLOOR |
| 95 | THIRD FLOOR |
| 96 | Providing internal cement plaster 20 millimetrethick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curingetc.complete. |
| 97 | GROUND FLOOR |
| 98 | FIRST FLOOR |
| 99 | SECOND FLOOR |
| 100 | THIRD FLOOR |
| 101 | Providing & applying 6 millimetrethick P.O.P.Punningfinished to ceilings & ceiling beam,walls including sacffolding ,forming jambs , corners, edges, cills, grooves , pattas, bands , making good to the holes left due to scaffoding at any level & height etc. complete. |
| 102 | GROUND FLOOR |
| 103 | FIRST FLOOR |
| 104 | SECOND FLOOR |
| 105 | THIRD FLOOR |
| 106 | Providing and applying average sand faced cement plaster 20 millimetrein two operations to brickand stone masonry and concrete surfaces in cement mortar 1:4, and providing and applying Chicken Mesh (Plaster Mesh) made from Galvanized Iron Coils of 0.35 millimetrethick, dipped in hot zinc coating of 120 gms per square metreof 200 millimetrewidth to building surfaces of masonry and concrete joints, cutting, fixing with nails, including scaffolding, curing, forming edges, sponged surface andfinishing the surfaces and cleaning with all leads and lifts etc. complete. |
| 107 | GROUND FLOOR |
| 108 | FIRST FLOOR |
| 109 | SECOND FLOOR |
| 110 | THIRD FLOOR |
| 111 | TOP TERRACE |
| 112 | Providing and applying acrylic emulsion MATT finish [two coats or more] (pastle colour) ofapproved brand and of required shade to give an even shade to the satisfaction of the CMC / Site-in-Charge on new work with preparing the surface and including a priming coat, including cost of scaffolding, cleaning the surface, for all type of elements in the structure at all levels with all leads and lifts etc. complete. |
| 113 | GROUND FLOOR |
| 114 | FIRST FLOOR |
| 115 | SECOND FLOOR |
| 116 | THIRD FLOOR |
| 117 | Providing and applyingAnti-fungal Exterior grade (Weather Coat) Paint TEXTURED finish (as per the manufacturers specification and application method) on the plastered surface and concrete surface in approved shade (3 coats), including necessary back coat, all necessary scaffolding, required tools and plants at all levels with all leads and lifts etc. complete. |
| 118 | GROUND FLOOR |
| 119 | FIRST FLOOR |
| 120 | SECOND FLOOR |
| 121 | THIRD FLOOR |
| 122 | TOP TERRACE |
| 123 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg. per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. |
| 124 | Providing water proof bedding for flooring of Bath and WC 25 millimetrethick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. |
| 125 | GROUND FLOOR |
| 126 | FIRST FLOOR |
| 127 | SECOND FLOOR |
| 128 | THIRD FLOOR |
| 129 | Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick cement mortar 1:3 with conceal, setcrete ( RMW ), Algaeproof or other alike water proofing liquids, raking of joints upto 35 mm depth,filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding cement concrete 1:3:6 base concrete). |
| 130 | Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 millimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete). |
| 131 | Providing andAppying waterproofing to water tanks in c.m.1:3 with aggrefate and finishing the surface with wayerproof plaster a9neat cement finish )with all lead & lift etc. complete |
| 132 | Providing and laying fully vitrified matt tiles, high stain resistant tiles of size 600 millimetrex 600millimetre(thickness as per manufacturers specification) for flooringwith bed mortar cement mortar1:4, filing the joints with grout agents and finishing the joints with grout sealants, as per pattern as shown in drawings including cutting (if required), neat finishing the surface at all levels with all leads and lifts etc. complete [Basic Rate : Rs.700 per sq.mt.]. |
| 133 | GROUND FLOOR |
| 134 | FIRST FLOOR |
| 135 | SECOND FLOOR |
| 136 | THIRD FLOOR |
| 137 | Providing and laying polished Kotah stone flooring & Skirting 25 millimetreto 30 millimetrethick & of required . width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. |
| 138 | GROUND FLOOR |
| 139 | FIRST FLOOR |
| 140 | SECOND FLOOR |
| 141 | THIRD FLOOR |
| 142 | Providing and laying Pre-Polished Granite ROUGH GRANITE (full length) of 18 millimetrethickness for Staircase RISER & Tread of approved quality and source in flooring using necessary cement bedding in cement mortar1:4 upto 20 millimetre thick average cement slurry for fixing the tiles with required slopes, curing, cleaning, filling the joints with pigments of similar colour and at all levels with all leads and lifts etc. complete as per directions of site in-charge and as per pattern required |
| 143 | GROUND FLOOR |
| 144 | FIRST FLOOR |
| 145 | SECOND FLOOR |
| 146 | THIRD FLOOR |
| 147 | Providing, making, and fixing Window Sills , Skirting door threshoulds made out pre-polished GRANITE JET BLACK as approved as per detailed drawings and specifications, fixing the same on masonry surface, concrete surface with stainless steel cleats and in cement mortar, corner joints at 45 degrees, edge champhered at all levels of the building with all leads and lifts etc. complete |
| 148 | GROUND FLOOR |
| 149 | FIRST FLOOR |
| 150 | SECOND FLOOR |
| 151 | THIRD FLOOR |
| 152 | Providing, making, and fixing Wash Basin Platform made out pre-polished GRANITE JET BLACK as approved as per detailed drawings and specifications, fixing the same on masonry surface, concrete surface with stainless steel cleats and in cement mortar, corner joints at 45 degrees, edge champhered including Kadappa undelay of minimum 35 mm thick at all levels of the building with all leads and lifts etc. complete |
| 153 | GROUND FLOOR |
| 154 | FIRST FLOOR |
| 155 | SECOND FLOOR |
| 156 | THIRD FLOOR |
| 157 | Providing & fixing coloured Vitrifid Glossy tiles 600 millimetrex 600 millimetrein size & about 6 millimetre thick for dado and skirting in required position on plaster of 1:4 cement mortar including filling joints with neat cement slurry mixed with pigment to match the colour of tiles, curing rubbing & polishing complete. |
| 158 | GROUND FLOOR |
| 159 | FIRST FLOOR |
| 160 | SECOND FLOOR |
| 161 | THIRD FLOOR |
| 162 | Providing, making, and fixing flooring of pre-polished GRANITE JET BLACK as approved as per detailed drawings and specifications in cement mortar1:4,19 millimetrethick at all levels of the building with all leads and lifts etc. complete [ |
| 163 | GROUND FLOOR |
| 164 | FIRST FLOOR |
| 165 | SECOND FLOOR |
| 166 | THIRD FLOOR |
| 167 | Providing, making, and fixing skirting of pre-polished GRANITE JET BLACK as approved as per detailed drawings and specifications in cement mortar1:4,19 millimetre thick at all levels of the building with all leads and lifts etc. complete |
| 168 | GROUND FLOOR |
| 169 | FIRST FLOOR |
| 170 | SECOND FLOOR |
| 171 | THIRD FLOOR |
| 172 | Providing & fixing in position Granite Urinal partitions both side polished with full moulding including necessary cutting joints filling etc. complete |
| 173 | GROUND FLOOR |
| 174 | FIRST FLOOR |
| 175 | SECOND FLOOR |
| 176 | THIRD FLOOR |
| 177 | Providing and laying fully vitrified tiles, high stain resistant tiles of size 600 millimetrex 600 millimetre(thickness as per manufacturers specification) forSKIRTING with bed mortar cement mortar1:4, filing the joints with grout agents and finishing the joints with grout sealants, as per pattern as shown in drawings including cutting (if required), neat finishing the surface at all levels with all leads and lifts etc. complete [Basic Rate : Rs. 700 per sq.mt.]. |
| 178 | GROUND FLOOR |
| 179 | FIRST FLOOR |
| 180 | SECOND FLOOR |
| 181 | THIRD FLOOR |
| 182 | Providing and fixing frame with/ without ventilator of size as specified with country cutteak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 mm x 40 mm x 5 mm with mellamyne polish, etc.complete |
| 183 | GROUND FLOOR |
| 184 | FIRST FLOOR |
| 185 | SECOND FLOOR |
| 186 | THIRD FLOOR |
| 187 | Providing and fixing 32 millimetrethick flush door shutters (solid core type) from approved manufacturer conforming to IS:2202-Part-I, having core of block board construction andincluding p/f seasoned hard wood integral lipping of 25 mm thick all around the shutter (over all area of the shutter to be measured), including p/f 4 nos. heavy type 125 mm long thick SS butt hinges with matching screws in each shutter. The both side of the shutter are to be provided with 1 mm thick laminate Edges To be polished With French Polish.including all SSHardware Dorma or equivalent make (12inch tower bolt 2 no..,12 inch handle 2 no..,14 inch Aldrop6 inch hinges 3 no. for each shutter ) etc complete. |
| 188 | GROUND FLOOR |
| 189 | FIRST FLOOR |
| 190 | SECOND FLOOR |
| 191 | THIRD FLOOR |
| 192 | Providing and fixing Country cut Teak Wood, Double or Single leaf second class fully panelled Door Shutter with 35 millimetrethick style and rail with 25 millimetrethick panels with openable fan light as per detailed drawings. Excluding the door frame 60 millimetrex 100 millimetre. Stainless Steel fixtures Dorma or equivalent make(12 inch tower bolt,14inch aldrop 6\" hinges for eachshutter,6inch handle 2 number for eachshutter door stopeeretc.) and fastenings and finishing the wood work with mellamyne polish. (Excluding the door frame) |
| 193 | Providing and fixing in position Aluminium System Window of two tracks with 27 millimetreseries, using Jindal or equivalent make Aluminium sections (Virgin quality and T6 Alloy) with 6mm thick Toughened / Annealed High Performance Glass (Low Solar Factor) and EPDM gasket, and SS Flyproof Mesh, with Multi point Locking System, and adjustable type SS rollers encased in Teflon gasket and joinery of frame as well as of shutters on crimping or cleating system to acheive accuracy in 45 degrees joints, complete with all necessary accessories in Pure Nylon make and fitting with Nylon, Rawl Plug and SS 304 Fastners. As per detailed drawings and as directed by Engineer in charge.With Colour Anodizing minimum20 micron (+/-) 3micromin approved colour, OR With Powder coating minimum 60 micron (+/-) 3micron in approved colour. The samples of Aluminium sections, Glass and all accesories needs prior approval of Engineer-In-Charge, before procuring the same. |
| 194 | GROUND FLOOR |
| 195 | FIRST FLOOR |
| 196 | SECOND FLOOR |
| 197 | THIRD FLOOR |
| 198 | Providing and fixing in position Aluminium System Window of three tracks with 27 millimetreseries, using Jindal or equivalent make Aluminium sections (Virgin quality and T6 Alloy) with 6 millimetrethick Toughened / Annealed High Performance Glass (Low Solar Factor) and EPDM gasket, and SS Flyproof Mesh, with Multi point Locking System, and adjustable type SS rollers encased in Teflon gasket and joinery of frame as well as of shutters on crimping or cleating system to acheive accuracy in 45 degrees joints, complete with all necessary accessories in Pure Nylon make and fitting with Nylon, Rawl Plug and SS 304 Fastners. As per detailed drawings and as directed by Engineer in charge.With Colour Anodizing minimum20 micron (+/-) 3micromin approved colour, OR With Powder coating minimum 60 micron (+/-) 3micron in approved colour. The samples of Aluminium sections, Glass and all accesories needs prior approval of Engineer-In-Charge, before procuring the same.x |
| 199 | GROUND FLOOR |
| 200 | FIRST FLOOR |
| 201 | SECOND FLOOR |
| 202 | THIRD FLOOR |
| 203 | Providing, making, and fixing door frames made out pre-polished GRANITE JET BLACK as per detailed drawings and specifications, fixing the same on masonry surface, concrete surface with stainless steel cleats and in cement mortar, corner joints at 45 degrees, edge champhered, making the locking arrangement at all levels of the building with all leads and lifts etc. complete [Bidders to consider the door frameas a single element comprising of two granite strips attached with each other) |
| 204 | GROUND FLOOR |
| 205 | FIRST FLOOR |
| 206 | SECOND FLOOR |
| 207 | THIRD FLOOR |
| 208 | Providing & fixing mild steel grill work for windows , ventilators etc.20 kilogramme per square metre as per drawing including fixtures necessary welding and painting with one coats of anti corrosive Paint & two coats of oil apinting complete. |
| 209 | GROUND FLOOR |
| 210 | FIRST FLOOR |
| 211 | SECOND FLOOR |
| 212 | THIRD FLOOR |
| 213 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimetrewith lack plate of 3.15 millimetrethickness reinforced with 35X35X5 millimetre angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 millimetreand 3.15 millimetrerespectively with hold fast arrangements, M.S. Bracket plate 300 X 300 X 3.15 millimetreminimum size and shape with square bar, suspension shaft of minimum 32 millimetrediameter, hood cover of M.S. sheet not less than 0.9 millimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. |
| 214 | Providing and mild steel Grill Door 24 kilogram per square metreof various size, as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting etc. complete. SSR Sr.No. 1400, Page No.265, As directed by Engineer-In-Charge. |
| 215 | Providing and fixing in position powder coated aluminium louvered windows/ ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 millimetrex 38millimetrex 1.22 millimetrebox type, 5 millimetrethick sheet glass louvers, of approved quality etc. complete. |
| 216 | GROUND FLOOR |
| 217 | FIRST FLOOR |
| 218 | SECOND FLOOR |
| 219 | THIRD FLOOR |
| 220 | Providing & Fixing Semi Unitised Structural Glazed Façade. Main Frame made from TEA make Structural Glazing Sections having dimensions 56 x 81 millimetreAluminium section duely colour anodisded 22 microns. to withstand the wind pressure of 1 K/PA. Frame fabricated & assembled & mechanically joined in grid pattern, with S.S. Screws (306 Grade) & Aluminium heavy duty cleats. Framed installed in position fixed on M.S. powder coated brackets & S.S. Anchor fastners of Hilti, Fischer, Wruth make fixed to the RCC Colums, Beams & soffit. Glazed panel made from Aluminium sash sections. 6 mm Bronze Reflective Toughened Glass (Gujarat Guardian, Saint Gobain) or equivalent make pasted on the sash frame with Adhesive Spacer Tape & Structural Sealant (Dow Corning) or equivalent make. The Glazed panels will be fixed to the main frame with Aluminium Toggle sections mechanically fixed with S.S. Screws. The outer face glass to glass joints sealled with Backer Rods & Weather Sealant (Dow Corning) or equivalent make. The gap between (Wall, Beam, Column & Soffit) & Structural Glazing Main Frame should be sealled & made Air / Water tight with Aluminium powder coated Flashings & Weather sealant. |
| 221 | Extra Over Providing & Fixing Semi Unitised Structural Glazed Top Hung Openable Shutters in the Façade. Outer frame made from Aluminium casement frame section. Shutter made from casement shutter section. Aluminium section duely colour anodisded 22 microns. Frame fabricated & assembled & mechanically joined with S.S. Screws (306 Grade) & Aluminium heavy duty cleats. Shutter installed in position with heavy duty 4 Bar armed S.S. (306 grade) Friction stay. Shutter panel 6 mm Bronze Reflective Toughened Glass (Gujarat Guardian, Saint Gobain) or equivalent make pasted on the sash frame with Adhesive Spacer Tape & Structural Sealant (Dow Corning) or equivalent make. The Shutter will be rovided with Heavy Duty Single Point Handle cum Lock. Outer frame should be made Air / Water tight with Weather sealant. |
| 222 | Providing and fixing 32 millimetre thick flush door shutters (for toilet)(solid core type) from approved manufacturer conforming to IS:2202-Part-I, having core of block board construction andincluding p/f seasoned hard wood integral lipping of 25 millimetrethick all around the shutter (over all area of the shutter to be measured), including p/f 4 nos. heavy type 125 mm long thick SS butt hinges with matching screws in each shutter. The both side of the shutter are to be provided with 1 mm thick laminate Edges To be polished With French Polish.including all SSHardware Dorma or equivalent make (8 inch tower bolt 8inch handle 2 no.,8 inch Aldrop 6 inch hinges 3 no.for each shutter ) etc complete. |
| 223 | GROUND FLOOR |
| 224 | FIRST FLOOR |
| 225 | SECOND FLOOR |
| 226 | THIRD FLOOR |
| 227 | Providing and fixing 900millimetre high S.S. 304 Grade Stainless steel railing with 40millimetre diameter and 1.5millimetrethick at top, 40millimetre diameter and 1.5millimetrethick vertical supports spaced at 1.5 metre center to center and 8millimetrethick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. |
| 228 | Providing and fixing in position Colour Anodized Aluminiumfixed window fully glazed of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminiumsections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. |
| 229 | Providing,Installation,Fixing, Testing, Commissionings ofEWC Hindware White ARMADA with trapc.i. walll hung bracket, PVC seat and lid with chromium plated brass hinges rubber buffer includingmetropole flush valve Jaquar make cat No. FLV 10895Q Health fauset Jquar make ALD -573 with two way bib cock cutting, grooving making good the walls and floors etc. complete. |
| 230 | Providing,Installation,Fixing, Testing, Commissionings ofEWC Hindware White ARMADA with trapc.i. walll hung bracket, PVC seat and lid with chromium plated brass hinges rubber buffer includingflushing cistern angle cock pvc connection Health fauset Jquar make ALD -573 with two way bib cock cutting, grooving making good the walls and floors etc. complete. |
| 231 | Fixing first qualityglazed vitreous china wash hand basin of approved colour with granite counter support,32 millimetre C.P. brass waste coupling, C.P. brass cast \"P\" trap withnecessary union, 32 millimetrediameterC.P. pipe to wall and C.P wall flange pvc connection Jaquar make angle and pillar cock complete including cutting &making good the walls wherever required. |
| 232 | 15 millimetre diameter angle cock with 15 millimetre diameterCP connector of required length for wash hand basins, washing machine, water purifier points. |
| 233 | 15 mm dia two way C.P. brass bib cock with health faucet with built in filter and wall flange complete. |
| 234 | Square C.P.brassgratingwith C.P. brass frame with anti-cockroach trap includingfixing to the floor withcement mortar and colour grout etc complete |
| 235 | 150 mm dia - Toilet grating |
| 236 | Providing,Installation,Fixing, Testing,Commissionings ofU-PVC, SWR grade selfit pipes,Pipes on exposed wall for carrying soil & waste water.The rates should include necessary cutting to the required length including shortpieces Assorted fittings such as Plug /PlainTee and bend single / double Y, Offsets, etc. jointing with solvent cement solution.Giving water tightness test for pipes,making holes in walls / floor etc.complete. (Makess:- Finolex , Supreme ) |
| 237 | 32 millimetre diameter |
| 238 | 50millimetre diameter |
| 239 | 80millimetre diameter |
| 240 | 110millimetre diameter |
| 241 | Providing and fixing PVC Floor trap (multi-type) of self cleansing design with water seal not less than 50 millimetre, saddle piece for 50 millimetrewaste water connections, set incement concrete 1:2:4 mix completeincluding cost of cutting and making good the walls and floors where required. |
| 242 | Providing and fixing UPVC pipes for Soil, Waste and Vent (IS13592-1992) Type B (6 Kg/sq.cm) including all fittings e.g.(plain or door) bends,junction, cowls, offsets, access pieces, jointing with rubber ring seal joints for vertical pipes (external) including cutting chase or holes in walls and floors and making good where required including fabricated stands, GI brackets, clamps, U-clips for pipe supports etc. complete.( for external drainage pipes in shafts) |
| 243 | 75 millimetre diameter |
| 244 | 110millimetre diameter |
| 245 | Providingand fixing UPVC pipes for Rainwater pipes (IS13592-1992) Type B (6 Kg/sq.cm) including all fittings e.g.(plain or door) bends,junction, cowls, offsets, access pieces at bends, jointingwith rubber ring joints for vertical pipes, including PVC gratings at terraces and balconies, including cutting chase or holes in walls and floors and making good where required including fabricated pipe supports, GI brackets, clamps, U-clips etc complete. |
| 246 | 110millimetre diameter |
| 247 | Making khurras (rainwater inlets)45 centimetre x 45 centimetre with averageminimumthickness of5centimetrecement concrete 1:2:4 overP.V.C. sheet1 metre x 1 metre x 400 micron,finished with 12millimetre cement plaster 1:3 anda coat of neat cement, rounding the edges, providing PVC grating, making andfinishingtheoutlet complete. |
| 248 | Providing,Installation,Fixing, Testing, Commissionings of C-PVC SDR 13.5 class pipes with C-PVC fittings hydraulic testing including a layer of plaster of Paris with chicken mesh for protection line, making holes & making good the damages by bringing them to good original condition & complete in all respect. (Make:- Astral ) |
| 249 | 15millimetre diameter |
| 250 | 20millimetre diameter |
| 251 | 25millimetre diameter |
| 252 | 32millimetre diameter. |
| 253 | 40millimetre diameter |
| 254 | Providing,Installation,Fixing, Testing, Commissionings of G.M. Ball valve ISI make with all required accessories & jointing material. (Makes:- Zoloto,Leader) |
| 255 | 15millimetre diameter |
| 256 | 20millimetre diameter |
| 257 | 25millimetre diameter |
| 258 | 32millimetre diameter |
| 259 | 40millimetre diameter |
| 260 | Providing,Constructing,Testing, lowering ,jointing stoneware well burnt pipes of the bestsalt glazed variety to a designed gradient and alignment by site rails and boning roads for proper levelling andmaking the joints water-tight by providing cement mortor 1:1joints hemp yarn.curing etc.complete as per IS and as per the engineer. |
| 261 | 100millimetre diameter |
| 262 | Providing, Constructing,Testing ofSewer trap (stone ware ) inside themanhole as perdirection of the Site Incharge including making good the damages, if made while fixing the sewer trap etc.complete. (Make:- Local) |
| 263 | 150millimetre diameter |
| 264 | Providing,Installation,Fixing,installation,Testing ofS.W. Gully traps of size150 millimetrex100 millimetrein cement concrete 1:4:8 including heavy cast iron grating over the gully trap weight of cover to be 7 kg & constructing burnt brick Masonrychamber, 300 millimetre x 300 millimetrenicely finished with 1:3 cement mortar from inside & outside cast ironhinged cover ofsize 300 x300 with frame etc. complete. (Make:- Local) |
| 265 | Providing, Constructing,Testing of Burnt Brick Masonry chamber of suitable size with cement concrete bedding 150 millimetrethick in cement mortor outside the B.B.masonry (150 millimetre ) in cement mortor1:6 and benching from inside with1:2:4 cement concreteand plasteringwith cement mortor 1:3 from inside and outside and fixing airtight cast ironcovers of following sizes.NECO make including curing etc.complete as per direction of the Architect.Weightof cover to be100 kilogrammesuitable for following sizes of inspection chambers. (Make:- Neco) |
| 266 | 450 millimetrex 900 millimetre (up to Depth of 1000 millimetre) |
| 267 | Providing, Constructing,Testing ofmanhole chambers of dia 1.4 meter & for connecting sewer lines of following depths in firstclass B.B. masonry works in 1:6 cement mortor including laying cement concrete bedding150mm thick of grade 1:3:6 for foundation and bedding and projecting 100mm outside the brick wall providing 20mm thick cement plaster (1:3)frominside with cement punning (Ghotai) 1:3 cement mortor foroutside &finish rough.Providing & fixing NECO C.I. Airthight manhole cover (heavyduty525 mm dia.)along with frame including providing and fixing C.I.Steps 300mm centre tocentre with a brick wall stenning of 2 bricks for taking load of passing vehicles.Benching of 1:2:4 cement concrete to be provided with cementplaster 1:3 and finish with cement punning the inside dia meter of 1.4 metre to continue vertical upto 0.45 metre above the benchingand then bricks stenning to slope towards top to adjust with cast iron cover frame etc. (Make:- Neco) |
| 268 | For depth of M.H. from 1.01 metre to 1.5 metre |
| 269 | Providing, Constructing,Testing, lowering ,jointing for RCC NP3 class (HUME pipe of standard make including jointing withcollars with hemp yarn, hot bitumen, sand, cement mortor (1:1) etc.complete including giving satisfactory hydraulic test and works to be executed as per ISS complete as per the direction of project engineer. (Make:- Dhere ) |
| 270 | 150millimetre diameter |
| 271 | 300millimetre diameter |
| 272 | Providing & constructing soak pit with excavation brickbat & sand filter bed as per the drawing etc. complete |
| 273 | Constructing brickmasonry chamber upto 1.5 metre deep,withfirst classbricks in cement mortar 1:5 Reinforced cement concretetop slab with 1:2:4 mix, foundation concrete 1:4:8 mix , inside and outsideplastering12millimetrethickwithcementmortar 1:3 finished with afloatingcoatofneat cementinsideand roughplaster onoutside and makingchannels in cement concrete 1:2:4 mix neatly finished complete as perstandard design including excavation refilling and disposalof surplus earth. |
| 274 | 90 centimetre x 45 centimetre inspection chamber with with Reinforced cement concretemanhole cover with frame (heavy duty) |
| 275 | Providing and fixing Orissatype white glazed earthenware 575 mm water closet pan including \"S\" trap with earthenware foot rests, upvc soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding with flushing tank and its accessories etc.complete. |
| 276 | BILL OF QUANTITIES - PART-II (Electrical Work).Memorandum showing the items of work to be carried out by the Contractor. |
| 277 | Supply , Assembly ,Testing, Transport to site, Unloading, Storage at Site, Installation & Commissioning of followingPanels with wherever required complete with base frame etc. as required & as per IEC 61439 specifications. the panel shall be CPRI approved. GA Drawing for approval to be submitted before Finalizing(Refer Single Line Diagram & Panel Specification Sheet & DB Specification Sheet ) In Case of Changes in Specs as per Tender and SLD the SLD shall be Treated as Final (Refer Electrical Technical Specification Part- C - Sr. No. - A - 1.0) |
| 278 | New Collage Bldg. Main LT Panel |
| 279 | Fire Pump Panel |
| 280 | Water Pump DB |
| 281 | 34 W Luminaire LED - Supplementary(Batten Type) SITC of suitable for Classroom Luminaire LED with supporting system of Ceiling surface mount & flexible cable 3c x 2.5 2XY from Ceiling Rose to Light fitting. High performance LED batten Sleek aesthetic design complements interiors, Slim integrated design, easy to install, Extruded aluminium housing, Suitable for Surface mounting & end cap Make: Philips, Model No.: BN0040S Optical : - System efficacy >125 LPM; CRI - 70; Power 34 W; Line Current: 0.21 A; PF. 0.95 CCT 5700; IP 40, (Refer Electrical Technical Specification Part- A - Sr. No. - A - 1.0) Subjected to approval of sample by Architect / client. |
| 282 | 7 W Luminaire LED (Batten Type) SITC of LEDLuminaire Batten Type with supporting systemof Wall/ Ceiling surface mount & flexible cable 3c x 2.5 2XY from Ceiling Rose to Light fitting. Optical : - System efficacy >100 LPM; CRI - 70; Power 7 W; Line Current: 0.03 A; PF. 0.95 CCT 5700; IP 20, (Refer Electrical Technical Specification Part- A - Sr. No. - A - 2.0) Subjected to approval of sample by Architect / client. |
| 283 | 30 W Luminaire LED Circular pendantSITC of LED Circular pendant Luminaire with supporting system & flexible cable 3c x 2.5 2XY from JB to Light fitting. Optical : - System efficacy >105 LPM; CRI - 70; Power 30 W; Line Current: 0.14 A; PF. 0.95 CCT 5700; IP 20, (Refer Electrical Technical Specification Part- A - Sr. No. - A - 3.0) Subjected to approval of sample by Architect / client. |
| 284 | Ceiling mounted Fan SITC of Ceiling mounted Fan confirming to IS: 374 /1979AMDT No. 1 to 6 Class - I ,50 Hz.Specification of Celling Fan must be as per below.(1) Sweep:1200 mm, (2) Operating Voltage:180 to 230 V, (3) Power Factor : >0.9, (4) Power Consumption :Between 50 to 56 W, (5) RPM: 370 to 380, (6) Air delivery: 215 to 220 CMM, (7) Service Value not below 4.1 cu mtr/min/watt. (8) Class of insulation :\"B\", (9) No. of Ball bearing: Two, (10) Total Body :Aluminium die cast, (11) Blade: Aluminium approx1.1 mm thick, (12) Colour: White high grade powder coating, (13) Canopy: Two Nos. Heavy duty,(14) Condenser: Branded make,(15) Down road: up to 1.5 mtr as per site tequirment.,(16)Required fixing accessories,(17) 3 core 1.0 sq.mm wire as per site requirment,(18) BEE Fan rating 5 star.(Crompton make High speed plus Five star rating, Bajaj make kassel Five star model, Havells make ES-50Five star rating makeorUsha,Orient make & model approved by engineer in charge subject to above specifications) including all hardware with Mounting kit etc. (Refer Electrical Technical Specification Part- A - Sr. No. - A - 4.0) |
| 285 | SITC Hi-Speed Fan (9\"\") ( propeller fan )Hi-Speed Fan (9\"\") ( propeller fan ) EXHAUST FAN With Supporting system. For Toilet Battary room Area wall mountin fan. Supports complete with alignment, fixing, cutting, wall cutout, framing , sealing with selaent along with the cabling, termination etc. to be done. Completely with standard accessories , inall respect as required at site, as per guideline & satisfaction of Engineer-in-charge.Rate shall be inculding with all respect with inculding support system.Subjected to approval of sample by Architect / client. (Refer Electrical Technical Specification Part- A - Sr. No. - A - 5.0) |
| 286 | SITC of Primary light point wiring SITC of Primary light point wiring with using Cu. wire shall be single core unsheathed industrial (multistrand) FRLS cable - . 1100 V gr. 2 x 1.5 sq. mm + 1 x 1.5 sq mm for Ph +N+Enon PVC insulation house wires (avgpoint length to be 18 mtrs.) with 20 mm H.M.S. PVC conduits ambedded in RCC work or in wall/floor with chiselling appropriately with The Wire shall be laid in the PVC Conduits in RCC work with necessary accessories like Junction Box, Ceiling rose, Clamps, Cleat, bend etc.Along with 6 A Switchs shall be Myrius with New white Face cover plates with frame, Concealed/Surface mounting boxes as per required erected on wall with all other required accessories etc. (Subjected to approval of sample by Architect / client for Switch, Plates extra) (Refer Electrical Technical Specification Part- A - Sr. No. - B - 6.0) |
| 287 | SITC of Secondary light point wiring SITC of Secondary light point wiring with using Cu. wire shall be single core unsheathed industrial (multistrand) cable - 1100 V gr. 2 x 1.5 sq. mm + 1 x 1.5 sq mm for Ph +N+Enon PVC insulation house wires (avgpoint length to be 8 mtrs.) with 20 mm H.M.S PVC conduits ambedded in RCC work. The Wire shall be laid in the PVC Conduits in RCC work with necessary accessories like Junction Box, Ceiling rose, Clamps, Cleat, bend etc complete as required. (Refer Electrical Technical Specification Part- A - Sr. No. - B - 7.0) |
| 288 | SITC of Primary Fan point wiring for Ceiling fanSITC of Primary light point wiring with using Cu. wire shall be single core unsheathed industrial (multistrand) FRLS cable - 1100 V gr. 2 x 2.5 sq. mm + 1 x 1.5 sq mm for Ph +N+Enon PVC insulation house wires (avgpoint length to be 25 mtrs.) with 25 mm H.M.S PVC conduits ambedded in RCC work or in wall/floor with chiselling appropriately with The Wire shall be laid in the PVC Conduits in RCC work with necessary accessories like Junction Box, Ceiling rose, Clamps, Cleat, bend etc.Along with 6 A Switchs, additional electronic step regulator (2Modular) shall be Myrius with New white Face cover plates with frame, Concealed/Surface mounting boxes as per required erected on wall with all other required accessories etc. (Subjected to approval of sample by Architect / client for Switch, Plates extra) (Refer Electrical Technical Specification Part- A - Sr. No. - B - 8.0) |
| 289 | SITC of Primary point wiring for Exhaust fanSITC of Primary light point wiring with using Cu. wire shall be single core unsheathed industrial (multistrand) FRLS cable - 1100 V gr. 2 x 2.5 sq. mm + 1 x 1.5 sq mm for Ph +N+Enon PVC insulation house wires (avgpoint length to be 20 mtrs.) with 20 mm H.M.S PVC conduits ambedded in RCC work or in wall/floor with chiselling appropriately with The Wire shall be laid in the PVC Conduits in RCC work with necessary accessories like Junction Box, Ceiling rose, Clamps, Cleat, bend etc.Along with 6 A Switchs, additional electronic step regulator (2Modular) shall be Myrius with New white Face cover plates with frame, Concealed/Surface mounting boxes as per required erected on wall with all other required accessories etc. (Subjected to approval of sample by Architect / client for Switch, Plates extra) (Refer Electrical Technical Specification Part- A - Sr. No. - B - 9.0) |
| 290 | SITC of Half pointSITC of Half point on each switch board, concealed in wall along withmodular 6A switch and 6A Universal socket erected on concealed/surfce lighting swich borad box complete as required.(Refer Electrical Technical Specification Part- A - Sr. No. - B - 10.0) |
| 291 | Supply, Installation, testing & Commissioning offollowing wiring mains to be carried through already laid H.M.S PVC Conduit, Concealed/cleated in wall/slab complete as required. (Refer Electrical Technical Specification Part- A- Sr. No. - B - 11.0) |
| 292 | Wiring Mains with 2 x 4 sq.mm + 1 x 1.5 sqmm with using non PVC insulation house Cu. wire shall be single core unsheathed industrial (multistrand) cable - FRLS 1100 V gr.for Ph +N+E for MDB to SB Cable to be laid in already layedH.M.S PVC Conduit, Concealed / cleated in wall/slab complete as required. |
| 293 | Wiring Mains with 2 x 2.5 sq.mm + 1 x 1.5 sqmm with using non PVC insulation house Cu. wire shall be single core unsheathed industrial (multistrand) cable - FRLS 1100 V gr.for Ph +N+E for MDB to SB Cable to be laid in already layedH.M.S PVC Conduit, Concealed / cleated in wall/slab complete as required. |
| 294 | Supply, Installation, testing & Commissioning of following H.M.S PVC Conduit to be Concealed/cleated in wall/slab. rate shall be including Junction Box, Ceiling rose, Clamps, Cleat, bend etc with all accessories complete as required. (Refer Electrical Technical Specification Part- A- Sr. No. - B - 12.0) |
| 295 | Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 296 | Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 297 | Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 298 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 299 | Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 300 | Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 301 | Supplying and erecting UPVC reinforcedflexible conduit 20 mm in dia. conforming toI.S. with requirednumberof couplings, PVC bushes, check nuts etc. complete. |
| 302 | Supply, , Installation, testing & Commissioning of following Modular Distribution Boards rate shall be including Supporitng structere to be considered in this item (as required on site) GI \"Z\" Type support shall be mounted on column as per Typ. drawing with complete hardware as required as per Specification & guideline of Engineer-in-charge of site.(Refer Electrical Technical Specification Part- A- Sr. No. - B - 13.0) |
| 303 | MDB - 01 to 10 |
| 304 | SITC of 1.1 KVGrade, IS 7098 Part- I and Part - II,XLPE & IS 1554 for PVC Insulated PVC or XLPE Sheathed Copper/Aluminium, Armoured / FlexiblePower Cables. To be erected cable tray in already ledrefer drawing. [Cable Must be Tested at Site with Mesuring the Insulation Resistance] cable to be properly Tied & Tagged to the supports of following sizes. refer Cable Shedule for details. (Refer Electrical Technical Specification Part - A- Sr. No. - B - 14.0) |
| 305 | 4 C x 16 Sqmm. A2XFY LT XLPE AL. Armoud Cable |
| 306 | 4 C x 10 Sqmm. 2XWY LT XLPE AL. Armoud Cable |
| 307 | 4 C x 6 Sqmm. 2XWY LT XLPE Cu. Armoud Cable |
| 308 | 3 C x 4 Sqmm. 2XY LT XLPE Cu. Flexible Cable |
| 309 | 3 C x 2.5 Sqmm. 2XY LT XLPE Cu. Flexible Cable |
| 310 | The scope shall include Supply, Installation, testing & Commissioning, of Cable end Termination Kits End termination for above cables including Brass heavy duty glands, lugs, Earth tag, locknet, shroud, supports, plated hardware like lugs / ferrules, Insulation tapes consumable etc. IS 7098 Part- I and Part - II, (With Material same as that of cable), Colour Coaded Insulation tape with Colour Coaded Insulation tape, ferruling, Plated Nut Bolts (As Per IS 1554 & IS 7098). cable to be properly Tied & Tagged to the supports etc. (All termination shall be done with Double compression gland), Alpha Numeric PVC ferrules to be used for each core for control cables. (End terminations for flexible cables will not be considered separately) (Refer Electrical Technical Specification Part - A- Sr. No.-B-15.0) |
| 311 | 4 C x 16 Sqmm. A2XFY LT XLPE AL. Armoud Cable (Double compression gland) |
| 312 | 4 C x 10 Sqmm. 2XWY LT XLPE Al. Armoud Cable (Double compression gland) |
| 313 | 4 C x 6 Sqmm. 2XWY LT XLPE Cu. Armoud Cable (Double compression gland) |
| 314 | 3 C x 4 Sqmm. 2XY LT XLPE Cu. Flexible Cable (Double compression gland) |
| 315 | 3 C x 2.5 Sqmm. 2XY LT XLPE Cu. Flexible Cable (Double compression gland) |
| 316 | Combination Industrial type 16 Amp 3 Ph 1 Nos; 32 Amp 3 Ph 1 Nos IPS WITH RCBOSITC of Combination type (3 ph & 1 ph) Industrial Power Socket with 5 Pin 16 A 3-Ph Socket & 3 Pin 32A 1-Ph Socket with 16A TPN MCB with RCBO 100 mA;& 32 A DP MCB with RCBO 100 mA, readymade IP 66 modular Power sockets with switch, in readymade Polycarbonate anti-corrosion modular box with other required accessories. Box should be suitable to terminate cables / wires easily, complete as required. (Industrial type P17 Tempra pro Legrand Make) to be mounted on column or wall with help of Clip Channels & as per requirement rate shall be including in this item with supporting system as required. (Refer Electrical Technical Specification Part - A- Sr. No.-C-16.0) |
| 317 | Industrial Power Socket of 161 Ph. IPS WITH RCBOSITC of Industrial Power Socket (1 ph) Industrial Power Socket with 3 Pin 16A 1-Ph Socket with 16A TPN MCB with RCBO 100 mA;in readymade IP 66 modular Power sockets with switch, in readymade Polycarbonate anti-corrosion modular box with other required accessories. Box should be suitable to terminate cables / wires easily, complete as required. (Industrial type P17 Tempra pro Legrand Make)to be mounted on column or wall with help of Clip Channels & as per requirement rate shall be including in this item. (Refer Electrical Technical Specification Part - A- Sr. No.-C-17.0) |
| 318 | Junction Box for Industrial Power SocketSITC of loop in loop out Junction box Material- UV Protected Heavy Duty PC-GFC polycarbonate, IP 65, Lockable, halogen-free; with 16 Nos.Terminal Enclosure Box for Power & Control Cable Termination for Terminate the 4c X 6 Sq.mm. 4 no’s Cable with Connect well connectors, with cable glands, Ring/Pin type Lug, & cable tag, number ferrule. mounted on cable tray at 4.0 m level rate shall be required supporting system Complete as required as per guideline of Engineer-in-charge of site. (Refer Electrical Technical Specification Part - A- Sr. No.-C-18.0) |
| 319 | SITC of Raw or UPS Power Socket (1 sockets and 1 switches)Rate shall be including 1 no’s 6/16 amp 5 Pin Multistrand Socket or universal socket 1 Nos 6 A Switch, switch & socket shall be Myrius along with New white plates with frame, Concealed metal boxes as per required erected on Concealed Box with all other required accessories etc. Switch socket Subjected to approval of sample by architect/ client (Refer Electrical Technical Specification Part - A- Sr. No.-C-22.0) |
| 320 | SITC of Raw or UPS Power Socket (1 sockets and 1 switches)Rate shall be including 1 no’s 16 amp 5 Pin universal socket & 1 Nos 16 A Switch, switch & socket shall be Myrius along with New white plates with frame, Concealed metal boxes as per required erected on Concealed with all other required accessories etc. Switch socket Subjected to approval of sample by architect/ client (Refer Electrical Technical Specification Part - A- Sr. No.-C-23.0) |
| 321 | Supply, Installation, testing & Commissioning offollowing wiring mains to be carried through already laid H.M.S PVC Conduit, Concealed/cleated in wall/slab complete as required. (Refer Electrical Technical Specification Part- A- Sr. No. - C - 24.0) |
| 322 | Wiring Mains with 2 x 4 sq.mm + 1 x 1.5 sqmm with using non PVC insulation house Cu. wire shall be single core unsheathed industrial (multistrand) cable - FRLS 1100 V gr.for Ph +N+E for MDB / UPSDB to Power Socket Cable to be laid in already layedH.M.S PVC Conduit, Concealed / cleated in wall/slab complete as required. |
| 323 | Wiring Mains with 2 x 2.5 sq.mm + 1 x 1.5 sqmm with using non PVC insulation house Cu. wire shall be single core unsheathed industrial (multistrand) cable - FRLS 1100 V gr.for Ph +N+E for MDB / UPSDB to Power Socket Cable to be laid in already layedH.M.S PVC Conduit, Concealed / cleated in wall/slab complete as required. |
| 324 | Supply, Installation, testing & Commissioning of following H.M.S PVC Conduit to be Concealed/cleated in wall/slab. rate shall be including Junction Box, Ceiling rose, Clamps, Cleat, bend etc with all accessories complete as required. (Refer Electrical Technical Specification Part- A- Sr. No. - C - 25.0) |
| 325 | Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 326 | Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 327 | Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 328 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 329 | Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 330 | Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 331 | Supply, , Installation, testing & Commissioning of following Modular Distribution Boards rate shall be including Supporitng structere to be considered in this item (as required on site) GI \"Z\" Type support shall be mounted on column as per Typ. drawing with complete hardware as required as per Specification & guideline of Engineer-in-charge of site.(Refer Electrical Technical Specification Part- A- Sr. No. - C - 26.0) |
| 332 | Main UPS DB |
| 333 | UPS DB |
| 334 | Lift Duct Switch Board as per Drawing (2 nos of 16 amp. Switch & 1 nos of Socket, and 10 W Bulkhead) |
| 335 | SITC of UPS Isolator IP 65 EnclosuresSITC of IP 65 Enclosures with Incomer/Outgoing 1 nos. 3 Ph. 32 Amps. Outdoor Type with polycarbonate housing to be installed on wall for UPS. Class II insulated enclosure, Impact resistant reinforced polystyrene , IP65 - IK09, Box: light grey, Cover: dark grey, Marker holder: transparent blue, Double closing point to ensure a good seal. Handle can be fitted with a lock. to gaurantee safety. rate shall be inculding with required support, Complete as required as per Specification & guidelineof Engineer-in-charge of site. (Refer Electrical Technical Specification Part- A - Sr. No. - C - 28) |
| 336 | 3 KVA UPS System- SNMP CommunicableSupply, Installation, Assembly ,Testing, Unloading , Storage at Site, Installation & Commissioning of 3 KVA UPS System with 10 min Battary back up, Battary Charger, DC & AC Cable & Rack along with Support system & accessories, panel , cables and structure etc. as per site condition with wherever as required. Sealed Maint Free battery bank with stand. Three phase Input & Single Phase Output with 32 TPN MCB for incoming isolation. (Refer Electrical Technical Specification Part- A - Sr. No. - C - 29) |
| 337 | SITC of 1.1 KVGrade, IS 7098 Part- I and Part - II,XLPE & IS 1554 for PVC Insulated PVC or XLPE Sheathed Copper/Aluminium, Armoured / FlexiblePower Cables. To be erected cable tray in already ledrefer drawing. [Cable Must be Tested at Site with Mesuring the Insulation Resistance] cable to be properly Tied & Tagged to the supports of following sizes. refer Cable Shedule for details. (Refer Electrical Technical Specification Part - A- Sr. No. - C - 29.0) |
| 338 | 4 C x 16 Sqmm. A2XFY LT XLPE AL. Armoud Cable |
| 339 | 4 C x 10 Sqmm. 2XWY LT XLPE AL. Armoud Cable |
| 340 | 3 C x 6 Sqmm. 2XWY LT XLPE Cu. Armoud Cable |
| 341 | 3 C x 4 Sqmm. 2XY LT XLPE Cu. Flexible Cable |
| 342 | 3 C x 2.5 Sqmm. 2XY LT XLPE Cu. Flexible Cable |
| 343 | The scope shall include Supply, Installation, testing & Commissioning, of Cable end Termination Kits End termination for above cables including Brass heavy duty glands, lugs, Earth tag, locknet, shroud, supports, plated hardware like lugs / ferrules, Insulation tapes consumable etc. IS 7098 Part- I and Part - II, (With Material same as that of cable), Colour Coaded Insulation tape with Colour Coaded Insulation tape, ferruling, Plated Nut Bolts (As Per IS 1554 & IS 7098). cable to be properly Tied & Tagged to the supports etc. (All termination shall be done with Double compression gland), Alpha Numeric PVC ferrules to be used for each core for control cables. (End terminations for flexible cables will not be considered separately) (Refer Electrical Technical Specification Part - A- Sr. No.-C-30.0) |
| 344 | 4 C x 16 Sqmm. A2XFY LT XLPE AL. Armoud Cable (Double compression gland) |
| 345 | 4 C x 10 Sqmm. 2XWY LT XLPE Al. Armoud Cable (Double compression gland) |
| 346 | 3 C x 6 Sqmm. 2XWY LT XLPE Cu. Armoud Cable (Double compression gland) |
| 347 | 3 C x 4 Sqmm. 2XY LT XLPE Cu. Flexible Cable (Double compression gland) |
| 348 | 3 C x 2.5 Sqmm. 2XY LT XLPE Cu. Flexible Cable (Double compression gland) |
| 349 | SITC of following GI Perforated Type Hot Deep Galvanized Cable Tray 14 SWG up to 450 mm & 12 SWG above 450 mm & 16 SWG GI Cover for Vertical down take All Accessories Like Coupler plates (Coupler plate size as per Tray collar Height), Shell headed Nut bolts, Nut Bolts to be Plated with Zinc Chromated. Tee, vertical & horizontal Bends, junctions, elbows etc. to be included in this item. Tray should carry at least 80 Kg/m uniform weight of cable. Standard length of cable tray shall be 3M Length Refer Drawing for Mounting to be mounted on readymade supports. such as Purlin/Rafter/wall/slab or anchor fastener, tie rod, AM strut. with appropriate supporting system. & Specification given in Tender Document complete as per Electrical guideline & site condition. Cutouts required as per site condition shall be considered in this item. (Refer Electrical Technical Specification Part- A - Sr. No. - D - 31.0) |
| 350 | 300 X 75 x 5 mm - 14 SWG. Thk - (All Accessories Like Tee, vertical & horizontal Bends, junctions, elbows etc. shall be Factory fabricated) |
| 351 | 200 X 75 x 5 mm - 14 SWG. Thk - (All Accessories Like Tee, vertical & horizontal Bends, junctions, elbows etc. shall be Factory fabricated) |
| 352 | 100 X 75 mm x 5 mm- 14 SWG. - (All Accessories Like Tee, vertical & horizontal Bends, junctions, elbows etc. shall be Factory fabricated) |
| 353 | 305 X 10 mm- 16 SWG. - (All Accessories Like Tee, vertical & horizontal Bends, junctions, elbows etc. shall be Factory fabricated) |
| 354 | 205 X 10 mm - 16 SWG. - (All Accessories Like Tee, vertical & horizontal Bends, junctions, elbows etc. shall be Factory fabricated) |
| 355 | 105 X 10 mm- 16 SWG. - (All Accessories Like Tee, vertical & horizontal Bends, junctions, elbows etc. shall be Factory fabricated) |
| 356 | SITC of Support System Refer Support Details\" A\" (Refer Electrical Technical Specification Part- A - Sr. No. - D - 31.7) |
| 357 | SITC of Support System Refer Support Details\" B\" (Refer Electrical Technical Specification Part- A - Sr. No. - D - 31.8) |
| 358 | FabricationSupply and Fabrication using MS angle , channels, Beams, plates, slooted rails for trays, DB panels, frames etc welded and including necessary painting with 2 coats of primer & & One Coat of Epoxy based paint with colour shade same as that of the structural members. & required hardware for fixing of supports etc. complete as required.(Refer Electrical Technical Specification Part- A - Sr. No. - D - 31.9) |
| 359 | SITC of 1.1 KVGrade, IS 7098 Part- I and Part - II,XLPE & IS 1554 for PVC Insulated PVC or XLPE Sheathed Copper/Aluminium, Armoured / FlexiblePower Cables. To be erected cable tray in already ledrefer drawing. [Cable Must be Tested at Site with Mesuring the Insulation Resistance] cable to be properly Tied & Tagged to the supports of following sizes. refer Cable Shedule for details. (Refer Electrical Technical Specification Part- C - Sr. No. - R - 124.0) |
| 360 | 4 C x 185 Sqmm. A2XFY LT XLPE Al. Armoured Cable |
| 361 | 4 C x 70 Sqmm. A2XFY LT XLPE Al. Armoured Cable |
| 362 | The scope shall include Supply, Installation, testing & Commissioning, of Cable end Termination Kits End termination for above cables including Brass heavy duty glands, lugs, Earth tag, locknet, shroud, supports, plated hardware like lugs / ferrules, Insulation tapes consumable etc. IS 7098 Part- I and Part - II,(With Material same as that of cable), Colour Coaded Insulation tape with Colour Coaded Insulation tape, ferruling, Plated Nut Bolts (As Per IS 1554 & IS 7098). cable to be properly Tied & Tagged to the supports etc. (All termination shall be done with Double compression gland), Alpha Numeric PVC ferrules to be used for each core for control cables. (End terminations for flexible cables will not be considered separately) (Refer Electrical Technical Specification Part- C - Sr. No. - R - 125.0) |
| 363 | 4 C x 185 Sqmm. A2XFY(Double compression gland) |
| 364 | 4 C x 70 Sqmm. 2XY (Double compression gland) |
| 365 | This specification provides for design, engineering, manufacture, inspection, testing and supply at site including transportation, erection, testing and commissioning of equipment as specified herein for following items complete as mentioned in technical specification sheet and as per schematic/layout drawing. the contractor shall be responsible for coordinating the equipment supplied. Any other material or accessory requirement which are not specifically mentioned, covered here but which are necessary or usual for satisfactory of carrier aided protection for successful commissioning of the system as per approved scheme are also within the scope of the Contract. The rate shall be included the activities and required accessories. (Refer Single Line Diagram, Layouts & Section; Technical Specification sheet & Data ) |
| 366 | SITC of Ready Made / Maintenance free Chemical Type GI Earthing Electrode with Pit and top funnel with wire-mesh with all neccessary material and making chamber, watering arrangement, cover heavy duty etc completeas per ISI 3043-1987. (Refer Sub-Station Layouts & Section; Technical Specification sheet & Data Sheet) (Refer Electrical Technical Specification sheet Part - A - Sr. No. - F - 35.0) |
| 367 | SITC of Cu. Pleted Ready Made / Maintenance free Chemical Type Cu Bonded Earthing Electrode with Pit and top funnel with wire-mesh with all neccessary material and making chamber, watering arrangement, cover heavy duty etc completeas per ISI 3043-1987. (Refer Sub-Station Layouts & Section; Technical Specification sheet & Data Sheet)(Refer Electrical Technical Specification sheet Part - A - Sr. No. - F - 36.0) |
| 368 | Five Prone Lightening ArrestorSIT of CU. Five Prone Lightening Arrestor to be installed on top of the factory roof, with proper clamping & down earth conductor for connection of lightning arrestr to earth pit. & Specification given in Tender Document complete as per EI guideline as required & as per site condition. (Refer Electrical Technical Specification sheet Part - A - Sr. No. - F - 37) |
| 369 | SITC of following GI (hot DIp Gavanized as per is 2629) ( Zinc Coating 65 micron Avg. as per is 4759) / CU earthing strip in ground at a depth of 300 mm including excavation and backfilling in all type of strata or in readymade trenches or Cable Traywith necessary strip saddele clamp at every 0.6 mtrs, Joint shall be done with Nut Bolts & Welding/Brazing joint. the same shall be Paited with Zinc Rich paint & Primer of Zinc Chormate. please also refer Photos & Specification given in Tender Document with necessary clamps, revette jointing as per specification complete required & as per EI guideline & required at as per site condition. (Jointing shall be done by welding overlapping/Brazing joint with Nut Bolts (Refer Earthing Layouts; Technical Specification sheet & Data Sheet) (Refer Electrical Technical Specification sheet Part - A - Sr. No. - F -40) |
| 370 | 50 X 6 GI. Thick Earth strip. with welding joint& min 1 no of Nut bolts on the overlapping, with paint as mentioned above. |
| 371 | 25 X 6 GI. Thick Earth strip. with welding joint& min 1 no of Nut bolts on the overlapping, with paint as mentioned above. |
| 372 | SITC of Earthing Cable offollowing size to be laying in Cable Tray or burried in ground including excavationand back filling in all type of strata or in readymade trenches or to be properly Tied & Tagged to the supports of following sizes including necessary accessories, spider, supports, plated hardware like lugs / ferrules, Insulation tapes etc. Including the termination of the same shall be done with ring type annealed Cu Lugs only. Cable shall be clamped with necessary clamps at an interval. the cable dressing shall be done propoerling and no loose cable shall be laid at any point. refer Cable Earthing Shedule for details. Cable shall be single core unsheathed industrial (multistrand) cable - FRLS with bright annealed electrolytic bare copper copper conductor. (Refer Earthing Layouts; Technical Specification sheet & Data Sheet) (Refer Electrical Technical Specification sheet Part - C - Sr. No. - S -132) |
| 373 | Supply and Installation of 1.1kv 1c x 16 SQ MM Cu. Unarmoured earthing cable with required nos. of sockets on both sides of each piece of cable for Earthing of All the Equipments from earth grid etc. complete to the satisfaction of EIC |
| 374 | Supply and Installation of 1.1kv 1c x 6 SQ MM Cu. Unarmoured earthing cable with required nos. of sockets on both sides of each piece of cable for Earthing of All the Equipments from earth grid etc. complete to the satisfaction of EIC |
| 375 | Local push buttons station SITC of Local push buttons station Al, diacasting mono stable 2 push buttton ( start / stop) ,nonluminiuos facia , red and green, suitable for outdoor mouniting IP55 if required for domestic pump / sump pump / dewatering pump etc.Radius of Coverage Area. Rate shall be inculding with required supprot. (Refer Electrical Technical Specification sheet Part - A - Sr. No. - G - 42.0) |
| 376 | Supply and erection of prefabricted GI supports for trays, DB panels, frames etc.& required hardware for fixing of supports etc. complete as required. as per site condition. (Refer Electrical Technical Specification sheet Part - A - Sr. No. - G - 43.0) |
| 377 | G. I. slotted C-Channel, Size (40x30x2 mm) |
| 378 | 10 mm G. I. Threaded Rod with Threading Rod Coupler |
| 379 | G.I. C-clamp (Beam Clamp) as per Sample |
| 380 | G.I. G- Clamp (PurlinClamp) as per sample |
| 381 | G. I. hardware (bolts with double Washers)(used for supporting for the slotted C-Channel ) |
| 382 | Z-channel 50x50x2 MM (18 gauge) |
| 383 | Supply, installation, testing and commissioning of continuous duty submersible monoblock centrifugal non-clogging water pumps complete with 1 phase motor with all necessary protection and mechanical seal etc.Including electrical & controlcabling from pumpto the Pump panel.Vendor to submit proposed pump model with duty curve.Flow rate : 55.0_ LPM (1set= 1W+1S)Head : 15__MtsSolid Handling: 10-12 MMLocation : pump room for Tank filling fromWater TankerPurpose:Tank water fillingMOC : As per Specification. |
| 384 | Supply , Assembly ,Testing, Transport to site, Unloading, Storage at Site, Installation & Commissioning of followingPanels with wherever required complete with base frame etc. as required & as per IEC 61439 specifications. the panel shall be CPRI approved. GA Drawing for approval to be submitted before Finalizing(Refer Single Line Diagram & Panel Specification Sheet & DB Specification Sheet ) In Case of Changes in Specs as per Tender and SLD the SLD shall be Treated as Final (Refer Electrical Technical Specification Part- B - Sr. No. - H - 47.0) |
| 385 | External Area DB (outdoor IP 66) |
| 386 | 60 W LED Street Light Luminaire (Road Light) SITC of Fitting to be erected on 7 Mtrs High Street light Pole. Rate shall beinculding, Light, &3C X 1.5 sq. mm 2XY Cable from Fitting Upto Junction box etc. Complete as required(Refer Electrical Technical Specification Part - B - Sr. No. - I - 48.0) Subjected to approval of sample by Architect / client. |
| 387 | 115 W LED Flood Light Fitting (Area/ Road / Security Light) SITC of LED Flood Light Illuminaire with 115 W IP65, Fitting to be erected on 13 Mtrs. high Street Light Pole. with Rate shall beinculding Supply & erection ofLight & 3 core 1.5 sqmm 2XY cable from JB to fitting through pole & arm & connection at both ends,from Fitting Upto Pole Junction box etc. necessary controlgear, lamp, hardware etc. including cable connection box. Complete as required as per Specification, guideline & satisfaction of Engineer-in-chargeof site. (Refer Electrical Technical Specification Part - B - Sr. No. - I - 49.0) Subjected to approval of sample by Architect / client. |
| 388 | Bollard fitting 9 W LEDSITC of Bollard fitting Decorative post top lanterns suitable & with 9 W LEDspherical/ flying disc type or lantern type with milky white opal polycarbonate housing , glass facia complete with gear box, capacitorwith decorative mounting shackle etc. Similar to Model No-LBL-846 Hybec. Complete as required as per guideline & satisfaction of Engineer-in-chargeof site. (Refer Electrical Technical Specification Part - B - Sr. No. - I - 50.0) Subjected to approval of sample by Architect / client. |
| 389 | Gate Lights Decorative post top lanterns suitable & with 20 W LEDSITC of Gate LightsDecorative post top lanterns suitable & with 20 W LEDspherical/ flying disc type or lantern type with milky white opal polycarbonate housing , glass facia complete with gear box, capacitorwith decorative mounting shackle etc. Similar to Model No-HLO-5003Hybec. Complete as required.Specification given in Tender Document & as per EI guideline & site condition. (Refer Electrical Technical Specification Part - B - Sr. No. - I - 51.0) Subjected to approval of sample by Architect / client. |
| 390 | Street Light pole Supply & erection of octagonal hot dipped galvanized pole 7mtr. height pole with Rod type earthing & Flush JB with MCB (Refer Electrical Technical Specification Part - B - Sr. No. - J - 52.0) |
| 391 | Flood Light poles Supply, Installation ,testing & Commissioning of flood light poles octagonal hot dipped galvanized pole 13 mtr. pole with Rod earthing & Flush JB with MCB (Refer Electrical Technical Specification Part - B - Sr. No. - J - 53.0) |
| 392 | SITC of Single Arm Bracket (L=1200mm) for above fittings made out of 50mm GI Pipe complete with pole cap, tightening screws (--nos.), hole for cable entry, to be erectd on pole of 7 mtrs. High. Complete as required as per guideline & satisfaction of Engineer-in-chargeof site. (Refer Electrical Technical Specification Part - B - Sr. No. - J - 54.0) |
| 393 | SITC of Double Arm Bracket (L=1200mm) for above fittings made out of 50mm GI Pipe complete with pole cap, tightening screws (--nos.), hole for cable entry, to be erectd on pole of 7 mtrs. High. Complete as required as per guideline & satisfaction of Engineer-in-chargeof site. (Refer Electrical Technical Specification Part - B - Sr. No. - J - 55.0) |
| 394 | SITC of R.C.C. Foundation for Street light above Street Light pole :-40 mm dia 1400 mm long GI. guard pipes bend to shape in foundation for cable entry, other details as per drawing painting with 2 coats of primer & white cement paintincluding excavation of pole pit in all types of strata. complete as required.Complete as required as per guideline & satisfaction of Engineer-in-chargeof site (Refer Electrical Technical Specification Part - B - Sr. No. - J - 56.0) Subjected to approval of sample by Architect / client. |
| 395 | SITC of R.C.C. Foundation for flood light above Street Light pole :-40 mm dia 2200 mm long GI. pipes bend to shape in foundation for cable entry, other details as per drawing painting with 2 coats of primer & white cement paintincluding excavation of pole pit in all types of strata. complete as required.Complete as required as per guideline & satisfaction of Engineer-in-chargeof site. (Refer Electrical Technical Specification Part - B - Sr. No. - J - 57.0) Subjected to approval of sample by Architect / client. |
| 396 | SITC of 1.1 KVGrade, IS 7098 Part- I and Part - II,XLPE & IS 1554 for PVC Insulated PVC or XLPE Sheathed Copper/Aluminium, Armoured / FlexiblePower Cables. To be erected cable tray in already ledrefer drawing. [Cable Must be Tested at Site with Mesuring the Insulation Resistance] cable to be properly Tied & Tagged to the supports of following sizes. refer Cable Shedule for details. (Refer Electrical Technical Specification Part - B - Sr. No. - K - 58.0) |
| 397 | 4 C x 4 Sqmm. 2XWY, LT XLPE Cable (from External area DB to JB) |
| 398 | 3 C x 2.5 Sqmm.2XWY, LT XLPE Cable (from External area DB to JB) |
| 399 | 3 C x 4 Sqmm. Cu. 2XY Cable (Rate Incuding termination) |
| 400 | 3 C x 2.5 Sqmm. Cu. 2XYCable (Rate Incuding termination) |
| 401 | The scope shall include Supply, Installation, testing & Commissioning, of Cable end Termination Kits End termination for above cables including Brass heavy duty glands, lugs, Earth tag, locknet, shroud, supports, plated hardware like lugs / ferrules, Insulation tapes consumable etc. IS 7098 Part- I and Part - II,(With Material same as that of cable), Colour Coaded Insulation tape with Colour Coaded Insulation tape, ferruling, Plated Nut Bolts (As Per IS 1554 & IS 7098). cable to be properly Tied & Tagged to the supports etc. (All termination shall be done with Double compression gland), Alpha Numeric PVC ferrules to be used for each core for control cables. (End terminations for flexible cables will not be considered separately) (Refer Electrical Technical Specification Part - B - Sr. No. - K - 59.0) |
| 402 | 4 C x 4 Sqmm. 2XWY, XLPE Cable (Double compression gland) |
| 403 | 3 C x 2.5 Sqmm.2XWY, LT XLPE Cable (Double compression gland) |
| 404 | Excavation in Hard Murum /Rock up to 1000 mm below ground levelRate to be quoted for Excavation & Backfilling complete. |
| 405 | Excavation in Soft Murum up to 1000 mm below ground levelRate to be quoted for Excavation & Backfilling complete. |
| 406 | SITC of 2 Loop Fire Alarm Control PanelNetworkable Multi Loop Intelligent analogue Addressable Fire Alarm Control Panel, Controller shall have color touch screen display with suitable cable marshling box for cable termination with cable-glands, lugs, cable trunks and installation channels, Control panel should be compatible for integration with existing SIEMENS FIRE CONTROL SYSTEM, and can support third party integration, panel should include 4 Loop driver cards, Address Card and extendiable up to 8 loop, each loop shall have a minimum capacity of 150 detectors & 150 devicesin one loop, Loop length 1.5 Km (300 mA) , Remote Keypads, and OPC servers; Connection to BIS Building Integration System ; Output current: LSN 0300 A- up to 300 mA; Cable length: LSN 0300 A - up to 1600 m. Four access levels, capable of taking Flash Scan devices, flash EPROM, sufficient numbers of programmable relay controls for controlling AHUs,ventilation fans, access control, The Panel shall have facility for integration with BMS. Inculding 240 volts AC power supply, automatic supervised battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 Minutes in emergency conditions as required. battery backup for 24 hrs.in standby mode & 30 min in alarm condition mode and with required accessories. Rate shall be Inculding with cable-glands, lugs ,Termination &all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 62.0) |
| 407 | SITC of NetworkableRepeater Panel 14.5 cm (5.7\") screen with sufficeint fixed keys, up to 32 Panel Controllers, Remote Keypads andwith inbuilt networking port. The Repeater Panel shall allow users to acknowledge, reset, silence, program, view hisory events...etc.(All functions similar to main panel) The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface. The events shall be displayed in different colors etc. for easy identification. The NRP shall be equipped with mounting options include an annunciator box, and blank modules are required for mounting. including all other accessories. Rate shall be Inculding with cable-glands, lugs ,Termination & all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 63.0) |
| 408 | SITC of Analogue Addressable Multi-Sensor Detectors Multi-Sensor Detectors with inbuilt isolators(Optical Smoke + Heat) with base box, Detectorsshall be Surface (ceiling) mounting with required suitable junction boxes, cable-glands, lugs, termination and other required installation accessories. Analog addressable detector with one optical and onethermal sensor, 360° visible red LED; Optical/Thermal with Rotary-Switches; Operating temperature: -20 °C to +50 °C. Monitoring area: Max. 60 m². Maximum installation height: Max. 8 m. Manually and automatically addressable; with Base for surface-mounted and flush-mounted cable feed; Housing material: ABS; The optical sensor element shall have multiple selectable sensitivity levels. Multis-sensor detector shall have a configuration mode that gives separate alarms for smoke detection and heat detection and shall indicate the cause of alarm (smoke or heat). Also the multi-sensor shall have combined configuration mode of smoke and heat detection that gives only one evaluated alarm from a multi-sensor detector in case of a fire event.Rate shall be Inculding all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 64.0) |
| 409 | SITC ofRate of Rise Thermal (Heat) detectorsAnalogue Addressable Rate of Rise Thermal (Heat) detectors cum Fixed Temperature Heat Detector with inbuilt isolators with base box, Detectorsshall be Surface (ceiling) mounting or Reccess Mounting with required suitable junction boxes, cable-glands, lugs, termination and other required installation accessories. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance. Detector should monitor Electromagnetic interference and report to the panel - current and average values. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 65.0) |
| 410 | SITC of Remote Response IndicatorResponse Indicator to be indicate the Fire Status of detectors above false ceiling and the detectors which are not in clear line of sight. Rate shall be Inculding with cable-glands, lugs and Termination, inculding required all other accessoriesand complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 66.0) |
| 411 | SITC of Power SupplyPower Supplyfor above Beam Detector. 24V 5 Amps Power Supply unit including M.S. painted box for wall / ceiling mount installation. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 67.0) |
| 412 | SITC of Analogue Addressable Manual Call PointsAnalogue Addressable, Double Action, Indoor Application, Manual Pull Stations / Manual Call Points suitable for wall / column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The same shall be square in shape & made of ABS plastic material. Surface / Flush Mounting. It shall have a \"Break glass\" message embedded on the glass.The addressable module shall be enclosed along with the break glass in a junction box. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 68.0) |
| 413 | SITC of Addressable Notification Appliances (Hooter with Strobe)Strobe cum Sounder Analog addressable base sounder for indoor use, vol. upto 91.2 dB, red; 5 different tone types can be selected, Frequency range 440 Hz up to 2.90 kHz, Sound pressure level at a distance of 1 m max. 92.1 dB(A), IP 43 *; and Analog addressable strobe, optical indication,flash rate of 1 Hz,red; Current consumption: 0.5 to 6.55 mA, Light intensity: > 2 cd, IP 42. with suitable junction boxes, cable-glands, lugs and required installation accessories. Hooter and Strobe elements of the combined unitshall have independent activation & deactivation criteria. Hooter shall stop at alarm \"Acknowledge\" and the Strobe shall stop at panel \"Reset\". The Hooter and Strobe element of Hooter cum Strobe combined unit shall be selected and triggered independently from FACP for performance check and maintenanace. Hooter with Strobe unit shall have provision to be tested by a hand-held field diagnostic tool in \"Silent Mode\" and \"Full Operation Sound Mode\". The Strobe shall have multiple selectable candela settings configured and selected from the FACP. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 69.0) |
| 414 | SITC of Addressable Supervised Monitor ModuleAnalogue Intelligent Addressable, Supervised Monitor Module monitoring Potential-free, Normally Open Dry Contact input. The Monitor Module shall have operating temperature range from 0°C to 70°C and a humidity tolerance of up to 93% RH, Non-Condensing for Conventional Detectors.withSurface / wall mounting box Rate shall be Inculding mentioned above required all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 70.0) |
| 415 | SITC OF Conventional Zone Module Conv. intrface modul 4 wire, 2 primary lines for 2- or 4-wire conv. detectors, type DIN rail; Allow conventional detectors to be connected to fire panels via a 4-wire supply network with Surface / wall mounting box Rate shall be Inculding mentioned above required all other accessories Complete as per guideline & site condition. (consider this item if Beam detector is non addressable) (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 71.0) |
| 416 | SITC of Control Relay ModuleAddressable relay interface module low voltage with 1 relay output, type in-built; Address setting: 8 DIP switches, Dimensions: Approx. 50 mm x 22 mm (Ø x H), IP 30. with Surface / wall mounting MS painted box. Rate shall be Inculding mentioned above required all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 72.0) |
| 417 | SITC of 2C x 1.5 Sq.mm Copper Armoured Multi stranded FRLS cable, Shield ismandatory. However if the manufacturer\"s data-sheet recommends unshield, then Unshielded cable shall be quoted.To be installed on cable tray / clited on wall / slab or structure with necessary spacer & saddles, cable to be properly Tied & Tagged to the supports. including necessary accessories, spider, supports, plated hardware like lugs / ferrules, Insulation tapes etc. scope shall alsoinclude required end termination using gland,lugs. Rate shall be Inculding mentioned above required all other accessories Complete as per guideline & site condition. (Red in Colour) (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 72.0) |
| 418 | SITC of4C x 1.5 Sq.mm Copper Armoured Multi strandedFRLS cable, (FM Approved) Shielded Twisted Pair. To be installed on cable tray / clited on wall / slab or structure with necessary spacer & saddles, cable to be properly Tied & Tagged to the supports. including necessary accessories, spider, supports, plated hardware like lugs / ferrules, Insulation tapes etc. scope shall also include required end termination using gland,lugs & required accessories. (Red in Colour) Rate shall be Inculding mentioned above required all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - N - 74.0) |
| 419 | SITC of Double shielded Cat 6 STP with EA link performance 4-pair, 23 AWG LAN CableCat 6A Cable Cable to be laid in through ready layed Raceways / Conduit / cable tray, Concealed in Floor / wall / slab ext. Rate shall be Inculding Cable with Performance testing & 25 year system warranty certificate with all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 75.0) |
| 420 | SITC of 24 PortLocable Jack Panel Preloaded ( with jack )24 Port Preloaded Jack Panel (Angular type) for Active Data for Rack Side suitable for above Cat 6 STP Cable with TerminationRate shall be Inculding Jack Panel; Cat 6 Jack ( RJ 45 Socket ) with Performance testing& 25 year system warranty certificate with all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 76.0) |
| 421 | SITC of Cat 6 STP RJ 45 Socket for Active DataCat 6 STP Jack( RJ 45 Socket ) - Active Data User Side suitable for above Cat 6 STP Cable with TerminationRate shall be Inculding RJ 45 Socket with Termination, Performance testing & 25 year system warranty with all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 77.0) |
| 422 | SITC of 1 Port Wall Plate Square1 Port Wall Plate Square Type Face Plates with Back box Rate shall be Inculding Face Plates, Back Box ( Surface / ConcealedM.S. BOX )with all other accessories Complete as per guideline & site condition. ( Module - Myrius / Artior ) (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 78.0) |
| 423 | SITC of Patch CordDouble shielded Cat 6 STP 4-pair, 27 AWG PVC Cords 2 Mtr. Length Rate shall be Inculding Cable with Performance testing & 25 year system warranty with all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 79.0) |
| 424 | SITC of Fiber Optic Cable(for IP PTZ CAMERA )Single Jacket All-Dielectric, Gel-Filled, Outdoor Central Tube Cable, 50/125 GM, OM3, MM, with 6 Fibre Optic Cable Rate shall be Inculding Cable with Performance testing & 25 year system warranty. Complete as perSpecification & guideline & site condition Including all other accessories.(Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 80.0) |
| 425 | SITC of HDMI Cable(for Display ) Length : 20 m (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 81.0) |
| 426 | SITC of Termination for 6 Fiber Optic Cable6F, 1U, LC MM OM3, (forIP PTZ CAMERA ) Loaded with Pigtails, Splice tray, adapter & splice protectors includingall other required accessories etc.( Rate shall be Inculding LIU, Coupler Plate, LC Duplex Adapter, Lazr SPEED, Multimode ,Fusion Tray, LC, MM Pigtail, 6 Feet ( 3 mtr ) 50/125 Ext ) Complete as perSpecification & guideline & site condition Including all other accessories with Performance testing & 25 year system warranty. (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 82.0) |
| 427 | SITC of LC-LC, MM Fiber Patch Cord, 10 Feet 50/125 Rate shall be Inculding Cable with Performance testing & 25 year system warranty with all other accessories Complete as per guideline & site condition. (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 83.0) |
| 428 | SITC of Ethernet to Fiber Media ConverterConverter required for connectivity for IP PTZ Camera with 6 Fiber Optic Cable (Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 84.0) |
| 429 | SITC ofRack Wall Mount 6 U / 600 mm with Including all other accessories, Mounting kit, front lockable glass door, Fan tray fro colling, Caster wheel base , Main Panel with Spike Buster, Unique key, Fan Module, Cable Maniger as required, Casters Set ext.including all internal wiring/ interconnection as required - Siemens Grey Colour, Complete as required for Data System.(Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 86.0) |
| 430 | SITC ofPower Distribution Unit 1Ph, 230 V, , Zero U standard rack mountwith Inlet Plug IEC30916A 4P +E, 16A MCB X 2 Circuits - PDU Rating 1 KVA.(Refer ELV Technical Specification sheet Part - C - Sr. No. - O - 87.0) |
| 431 | SITC ofIP IR Bullet Camera2 MP Varifocal Bullet Network Camera -1/2.8\"\" Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.7 to 13.5 mm Varifocal Auto iris lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, support H.265, H.264, MJPEG, 120db WDR, BLC, HLC, EIS, Defog, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 60m, Smart Supplement Light, Support on-board storage up to 256 GB (SD card not included), Alarm : 2 inputs & 2 outputs, Audio: 1 input & 1 output, IP67, IK10,Edge Analytics- Line crossing detection, intrusion detection, Scene change detection, Motion detection, Face capture, audio exception detection, Video tampering, False alarm reduction through human and vehicle target classification based on deep learning, UL, CE, FCC certified. Rate shall be Inculding Camera with required all other accessories with monting kit Complete as per guideline & site condition. |
| 432 | SITC of IR Fixed Bullet Network Camera 2 MP IR Fixed Bullet Network Camera 30 Mtrs -1/2.8? Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8/4 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, EIS, Defog,Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection,Face capture, Video tampering, audio exception detection,False alarm reduction through human and vehicle target classification based on deep learningUL, CE, FCC certified. Rate shall be Inculding Camera with required all other accessories with monting kit Complete as per guideline & site condition. |
| 433 | 2 MP IR Fixed Dome Network Camera 30 mtrs-1/2.8? Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8/4 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, EIS, Defog,Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection,False alarm reduction through human and vehicle target classification based on deep learningUL, CE, FCC certified. Rate shall be Inculding Camera with required all other accessories with monting kit Complete as per guideline & site condition. |
| 434 | SITC of IP65 2MP IR 1080p Full HD outdoor PTZ Camera2MP IR Outdoor PTZ Camera with 25X: 1/2.8\" Progressive Scan CMOS, 1920 × 1080 at 60fps, 4.8 mm to 120 mm, 25× Optical, 16x digital zoom, Color: 0.005 Lux at F1.6, B/W: 0.001Lux at F1.6, ICR, ONVIF, support H.265,MJPEG, 120 dB WDR, 3D Digital Noise Reduction, HLC, BLC, Defog, EIS, Tripple individually configurable stream, 24 VAC & Hi PoE, IR range: 150m, Pan: 360° endless, Tilt: From -15° to 90° (auto-flip), Pan Speed - from 0.1°/s to 160°/s, Preset Speed: 240°/s, Tilt Speed- from 0.1°/s to 120°/s, Preset Speed: 200°/s, Presets- 300, Alarm Input-2-ch alarm input, Alarm Output-1-ch alarm output, Audio-1 channel input & output, Support on-board storage up to 256 GB (SD card not included), IP66, IK10, Face Detection, Intrusion Detection, Line Crossing Detection, Region Entrance Detection, Region Exiting Detection, UL, CE, FCC certified. Rate shall be Inculding Camera with required all otheraccessories with Mountingkit Complete as per guideline & site condition. |
| 435 | SITC of 64 ch Network Video RecorderConnect Up to 64IP Cameras, Dual OS, Up to 12 Megapixels Resolution,HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output of 4K resolution, atleast 1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG,Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Supports Dual Power-Redundant,Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 8TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. Rate shall be Inculdingwith required all other accessories Complete as per guideline & site condition. |
| 436 | SITC of 8TB Surveillance Hard Disk |
| 437 | SITC of Operator WorkstationWorkstationwith latest i7 processor, 8 GB RAM, 2 TB HDD, keyboard, mouse, windows 11 Operating system, Graaphics Card: ATI 2GB. Software & Licenced Anti-Virus Software Rate shall be Inculdingwith required all other accessories Complete as per guideline & site condition. |
| 438 | SITC of 42inches Display samsung LED |
| 439 | SITC of Core Network Non-PoE Switch 24-Port GigabitManaged Switch with 12 SFP ports +12 UTP Ports switchmanagement Limited CLI/ SNMP support for discovery / mapping3.) |
| 440 | SITC of Network PoE Switch Full unmanagable switch24 x PoE ports, 390 W PoE budget, smart fans. |
| 441 | SITC of Fibre connectivity for Camera Network Switches1G SFP Module. |
| 442 | SITC of PoE-based devices, input voltage:- 100 to 240 V AC &output voltage 55 v DC (max 30 W) |
| 443 | SITC of IP 66 outdoor type Box. 6 U sizeSITC of IP 66 Enclosures outdoor type Box Required for 1 nos 6 Fiber Cable LIU termination, 1 nos Media Convertor 1 Nos Poe Injector 2 nos & 1 PDU & 1 8 port switch gigabit instalation in outdoor type Box. rate shall be inculding with required support. Complete as required as per Specification & guidelineof Engineer-in-charge of site. |
| 444 | SITC of Outdoor box for PTZ camera with 1 switch 2 socket IP 66 rated with gland and Pole mount accessories . |
| 445 | SITC of Camera Mount Box indoor with Glnds and mounting accessories |
| 446 | SITC ofCamera Mount Box outdoor with Glnds and mounting accessories |
| 447 | SITC of Fabricated stand for mounting of bullet camera fixed type 1ft Long |
| 448 | SITC of 10x SFPModule |
| 449 | SITC of Metal Grill Cabinet mount speaker with excellent speech & music reproductionRated Power: 6Watts, Power Tapping: 6/3/1.5W; Effective frequency range(-10 dB) : 180 Hz to 20KHz; SPL at 6W/1W (1Khz at 1 m) 102 dB / 94 dB; Opening angle at 1 kHz / 4 kHz (-6 dB): 180°/ 90° (horizontal) 180°/ 98°(vertical); EN54 Certified , IP 21; Rated Voltage 70V/100V; Wall Mount / Ceiling Mounted Speakers with line matching transformer & accessories & with mounting base, with suitable junction boxes, cable-glands, lugs and required installation accessories.,The speakers shall be of same make as that of the Control Panel & Amplifiers. all other accessories. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 450 | SITC of 15 W Premium-Sound Cabinet Loudspeaker15WCompact ABS cabinet speaker with weather protection of IP 65; Max. Power: 22.5 W,Rated Power: 15 W Watts, Power Tapping:15/7.5/3.75/1.9 W; Effective frequency range(-10 dB) :( 95 Hz to 20 kHz); SPL at rated power (1Khz) 99 dB; Self extingguishing acc. to UL94 V0; Safety acc. to EN60065; Chlorine resistant acc. to IEC60068-2-42; Corrosion resistant acc. to IEC60068-2-52; Salt mist acc. to IEC60068-2-11; aluminum/ABS material;Rate shall be Inculding with Wall Mounted Speakers with mounting base suitable junction boxes, cable-glands, lugs and Termination with required all other accessories,The speakers shall be of same make as that of the Control Panel & Amplifiers. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 451 | SITC of 30 WElliptical Horn Speakers. 30W Horn speaker with excellent speechreproduction; Max Power: 45 W W,Rated Power: 30 Watts; Effective frequency range(-10 dB) :490 Hz to 4500 Hz; SPL at rated power (1Khz at 1 m) 115 dB; Opening Angle 1 KHz / 4 KHz (-6 dB):112 (H) /85 (V); aluminum/ABS material; water and dust protected according IP65;light gray RAL 7035. Rate shall be Inculding with Speakers with mounting base suitable junction boxes, cable-glands, lugs and Termination with required all oher accessories,The speakers shall be of same make as that of the Control Panel & Amplifiers. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 452 | SITC of Call Station The Digital call station shall be an EN54-16 certified user interface. the call station shall have a gooseneck microphone with pop shield and permanent monitoring, an illuminated LC-display and an integrated loudspeaker to be used for system sounds. It shall be possible to modify the call station to suit the user’s requirements by connecting up to five remote call station extensions, each with 20 free customizable functions and selection buttons. The Call station shall have a built-in numerical keypad; it shall be possible to enable or disable the keypad during configuration. Five menu/function keys (pre-programmed) – four buttons shall provide each 1 LED (two LED’s shall be 2 green and 2 LED’s shall be yellow). Green led on the microphone which is active during a call 15 function and speed dial buttons (customizable), two LEDs (green/red) per button. Button functions shall be programmable such as: Zone select, source select, level control, emergency on/off, message on/off, failure acknowledge/reset.switching output trigger on/off or 0 to 10V, select scheduled events, scheduled event on/off. Technical specifications : CAN BUS port - 10, 20, or 62.5 kbit/s, RJ-45,Buttons - 5 pre-programmed, 15 programmable zone/function keys; Ports : 1 CST BUS port (Control data + Audio + Power supply, RJ-45) 1 audio source (line level, phone jack) 1 microphone port (phone jack) 1 EXT OUT port (call station extension, RJ-12) Maximum mic input level --21 dBu; Maximum line input level - +4 dBu; Maximum NF output level - +12 dBu; Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 453 | SITC of class-D Amplifier 2?500 W EN-54 certified2 x 500W Class D, high efficiency amplifier. 70/100V loudspeaker output voltages, galvanically separated, 4automatic selectable audio inputs on RJ45, local input. THD =1%. Frequency response, ref. 1 kHz, rated load, -3 dB : 50 Hz to 25 kHz. Signal-to-noise ratio (A-weighted) > 104 dB, Output noise (A-weighted) < -62 dBu topology - Class-D, transformer, floating Crosstalk , ref. 1 kHz < -85 dB. Protection - Audio inputlevel limiter, RMS output powerlimiter, high temperature, DC, shortcircuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter, groundfault Rated input voltage - +6 dBu;Input level, max. - +18 dBu (9.75 Vrms); Cooling - Front-to-rear, temperaturecontrolled fans; Safety class - Class I; Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 454 | SITC ofNetwork Controller SITC of EN-54 Certified EVAC PA controller with minimum 12 zones in the system and expandable upto 400 zones with 14x 4 Audio matrix with full DSP functionality. 8 audio inputs, 4 audio outputs, 4 channel output matrix. Shall support the following: single line switching or redundant group A/B switching,amplifier redundany, 4 x 100V audio inputs and12 speaker line outputs. 8000 fault, warning and event conditions log.Built in message manager for 100 emergency/business calls up to 85 minutes. 10 control inputs and 13 control outputs. Impedance measurement and Pilot Tone supervision for speaker line monitoring. Frequency response (ref.1 kHz) 20 Hz to 20 kHz (-0.5 dB), Signal-to-noise ratio(A-weighted): Line in to line out: 106 dB typical, THD+N < 0.05%, Crosstalk(linelevel) Line in to line out (0 dB gain): < 100 dB at 1 kHz, Sample rate 48 kHz, DSP processing resolution 24-bitlinear A/D and D/A conversion, 48-bitprocessing. Should be provided with a Configuration and Graphics User Interface Software. Audio inputs (100 V) : AMP IN: 2 ? 6-pin port; Max. voltage - 120 V; • Max. power - 500 W;PVA-4CR12 ;Component :1) PVA-4CR12 2) CAN terminating resistor (120 ohm) 3) Foot stand (self-adhesive) 3) Operation manual 4) Important safety instructions. Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 455 | SITC of Volume Controller as per follwing Size, Rate shall be Inculding with Volume Controller with Black Concealed / Surface box, Faceplate, lugs and Termination with required all oher accessories, The Volume Controller shall be of same make as that of the Control Panel & Amplifiers. |
| 456 | Power : 12 W (max) (Module: - BoschLBC1400/10);Attenuation Steps : 5 x 3 dB + off;Frequency Response :50 Hz to 20 kHz; Current Consumption : 20 mA @ 24 V DC; Connection : Screw terminals; Color : White (RAL 9010); Mounting : U40; Rate shall be Inculding all other required accessories such as a back box,faceplate etc. and complete as per guideline & site condition. |
| 457 | SITC of 760VGrade, Control Cable XLPE Sheathed Copper/Aluminium, Armoured / FlexiblePower Cables. To be erected cable tray in already ledrefer drawing. [CABLES MUST BE TESTED AT SITE WITH MEASURING THE INSULATION RESISTANCE] cable to be properly Tied & Tagged to the supports of following sizes including necessary accessories, spider, supports, plated hardware like lugs / ferrules, Insulation tapes etc. complete ot be installed from panel to panel, panel to DB, DB to DB, DB to Light, DB to Equiment, DB to Socket, DB to JB, JB to JB, JB to Panel/ DB, Panel to JB ext. refer Cable Shedule for details (Refer Technical Specification sheet) |
| 458 | SITC Speaker Cable of 2C x 1.5 Sq.mm 2XWY FRLS Insulated Cable withAnnealed Copper Conductor,Cable conforming to IS 694:1990for Voltage Grade upto 760 Volts. FRLS ; Cable to be laid in through ready layed G.I. Conduit / cable Tray, Concealed in Floor / wall/ slab or clited on wall / slab or structure ext. scope shall alsoinclude required end termination using gland, lugs & Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 459 | SITC Speaker Cable of 2C x 1.5 Sq.mm 2XY FRLS Insulated Cable withAnnealed Copper Conductor,Cable conforming to IS 694:1990for Voltage Grade upto 760 Volts. FRLS ; Cable to be laid in through ready layed G.I. Conduit / cable Tray, Concealed in Floor / wall/ slab or clited on wall / slab or structure ext. scope shall alsoinclude required end termination using gland, lugs & Rate shall be Inculding all other required accessories and complete as per guideline & site condition. |
| 460 | The scope shall include Supply, Installation, testing & Commissioning, of Cable end Termination Kits End termination for above cables including Brass heavy duty glands , lugs, consumable etc. IS 7098 Part- I and Part - II,(With Material same as that of cable), Colour Coaded Insulation tape with Colour Coaded Insulation tape, ferruling, Plated Nut Bolts (As Per IS 1554 & IS 7098). cable to be properly Tied & Tagged to the supports etc. Complete of following sizes including necessary accessories, spider, supports, plated hardware like lugs / ferrules, Insulation tapes etc.(All termination shall be done with Double compression gland), Alpha Numeric PVC ferrules to be used for each core for control cables. (End terminations for flexible cables will not be considered separately) |
| 461 | 2 C x 1.5 Sqmm. FRLS 2XWY LT XLPE Cu. Armourd Cable(Double compression gland) |
| 462 | 2 C x 1.5 Sqmm. FRLS 2XY LT XLPE Cu. Flex Cable(Double compression gland) |
| 463 | Fabrication Supply and Fabrication using MS angle , channels, Beams, plates, slooted rails for trays, DB panels, frames etc welded and including necessary painting with 2 coats of primer & & One Coat of Epoxy based paint with colour shade same as that of the structural members. & required hardware for fixing of supports etc. complete as required. |
| 464 | Junction Box for SpeakersSITC of loop in loop out Junction box Material- UV Protected Heavy Duty PC-GFC polycarbonate, IP 65, Lockable, halogen-free; with 16 Nos.Terminal Enclosure Box for Power & Control Cable Termination for Terminate the 2 c X 1.5 Sq.mm. 6 no’s Cable with Connect well connectors, with cable glands, Ring/Pin type Lug, & cable tag, number ferrule. mounted on cable tray at 6.0 m level rate shall be required supporting system Complete as required as per guideline of Engineer-in-charge of site. (Refer Electrical Technical Specification) |
| 465 | TOTAL COST OF ELECTRICAL WORK (i) |
| 466 | BILL OF QUANTITIES(Part-II (ii) (Fire-Fighting Work).Memorandum showing the items of work to be carried out by the Contractor. |
| 467 | SITC (Supply Installation testing & Commissioning) of UL ApprovedMAIN DIESEL ENGINE DRIVEN PUMP SET with Spilt casing CI casing & Bronze Impeller ( cooling media air , suction throgh radiator ) FOR FIRE HYDRANT/SPRINKLER SYSTEMwith Diesel Engine as Prime Mover with Diesel tank, batteries, exhaust system (Exhaust pipe of 20 meters minimum with M.S. medium grade with mineral wool insulation with aluminum sheet with required support). Batteries to be SMF lead acid along withBattery housing, Battery Charger, Automation Relays, push button, ignition key in compelete with weather proof Control Panel as required for Local ON /OFF Operation & Provision for Auto Start through Pressure Switch/Controller. Battery to be 12 V & 100 Ah. First Fill of Diesel, Lube Oil & Charged Battery for Commissioing are to be considered in the Rates. The quoted rate shall also includes heat exchanger water cooling piping, exhaust piping, coupling guard vibration pads , and other standard accessories,RCC foundation(as recommendedby manufacturer) )and foundation bolts , etc. complete. Unloading , storage, shifting to location and erection shall be included in the rates quoted.Type of Pump: centre suction, top discharge , centrifugal pump Capacity: 1200 lpm Head: 70 MtrDischarge efficiency : 150 % of rated flow CapacityMotor speed : ----- RPM Refer : Pump data sheet for detailed input of pump and motor |
| 468 | SITC (Supply Installation testing & Commissioning) of MAIN ELECTRIC MOTOR DRIVEN PUMP SET with Spilt casing ,CI casing & Bronze Impeller type (UL Approved) FOR SPRINKLER SYSTEM, The pump shall be coupled to TEFC motor The quoted rate shall includes providing Impeller, Shafts, Screwed coupling, imp shaft sleeve, complete set & RCC foundation (as recommended by manufacturer) and foundation bolts etc.The Motor for the pump should be sized for 150% discharge condition and the pump should follow the NFPA 20 curve.with foot mount assembly mounting frame, foundation bolts. Vendor to submit foot print drawing,Data Sheet, civil input & template for foundation casting. Unloading , storage, shifting to location and erection shall be included in the rates quoted. electrical work like cabling, cable trays, earthing, termination etc. is in your scope. Type of Pump: centre suction, top discharge , centrifugal pump Capacity: 1200 lpm Head: 70 MtrDischarge efficiency : 150 % of rated flow CapacityMotor speed : ---- RPMRefer : Pump data sheet for detailed input of pump and motor |
| 469 | SITC (Supply Installation testing & Commissioning) of MAIN ELECTRIC MOTOR BOOSTER PUMP SET with Spilt casing ,CI casing & Bronze Impeller type (UL Approved) FOR SPRINKLER SYSTEM, The pump shall be coupled to TEFC motor The quoted rate shall includes providing Impeller, Shafts, Screwed coupling, imp shaft sleeve, complete set & RCC foundation (as recommended by manufacturer) and foundation bolts etc.The Motor for the pump should be sized for 150% discharge condition and the pump should follow the NFPA 20 curve.with foot mount assembly mounting frame, foundation bolts. Vendor to submit foot print drawing,Data Sheet, civil input & template for foundation casting. Unloading , storage, shifting to location and erection shall be included in the rates quoted. electrical work like cabling, cable trays, earthing, termination etc. is in your scope. Type of Pump: centre suction, top discharge , centrifugal pump Capacity: 180 lpm Head: 70 MtrDischarge efficiency : 150 % of rated flow CapacityMotor speed : ---- RPMRefer : Pump data sheet for detailed input of pump and motor |
| 470 | SITC(Supply, Installation, testing and commissioning) of Above Ground ERW GIPipeClass C ( as per IS: 1239 Pt -I Heavy Grade upto 150NB & above IS: 3589) including all fittings like couplings, bends, tees, U Clamps with EPDM rubber, slip on flanges, concentric & eccentric reducersand ring gasket Gaskets. Rate shall include pipe cutting, Jointing (welding / flanged joints) along with necessary washers, nuts, bolts, as required for Complete piping work, Nuts, bolts and double plain washers & one soring washer shall behot dipped galvanized.Civil cutout is in your scope. |
| 471 | Method of Painting & Piping Work :- The pipe surfaceshallbemanually cleanedofrust / mill scales by wirebrush, Use of Whipping hammer, emery papershallbe done to clean pitted areas. Above ground piping shall be Painted with zinc Chromate primer and final 2 coats of Enamel Paint “ PO-RED“. Painting material shall be low volatile organic compounds (VOC ) material. Thepiping shall be laid & fixed above ground. The pipes to be mounted on support structure OR fixed on to the wall by clamps and hardware or suspended from the ceiling / truss with angle / channel / fabricated iron supports complete with Primer & black paint .Following are the piping sizes.(Civil Stubs and Supports to be Quoted Separately in Item Number below). |
| 472 | 15 NB (For Air Vent, Pressure Gauge and Pressure Switch Connection) |
| 473 | 25 NB |
| 474 | 32 NB |
| 475 | 50 NB |
| 476 | 65 NB |
| 477 | 80 NB |
| 478 | 125 NB |
| 479 | 150 NB |
| 480 | 150 NB (Testing drain line) |
| 481 | SITC of WafertypeNon ReturnValves, (ISI marked) flange end , SGIBody, SGI Disc, EPDM sealing , Pressure ratting of PN 16. Operating temperature range of 0 C to 150 deg.C. Rate shall include for supply and providing companion, flanges, necessary gaskets,hot dipped galvanized nuts-bolts with double washer of following sizes. |
| 482 | 25 NB |
| 483 | 50 NB (Booster Pump) |
| 484 | 65 NB |
| 485 | 80 NB |
| 486 | 125 NB |
| 487 | 150 NB (Main Elctrcal Sprinkler & Hydrant pump ) |
| 488 | SITC of 3 piece BALL VALVE Floating design (ISI marked) screwed ends A 105 Body , SS 304 ball, PTFE seat, SS 304 Stem,Class 800 ISI marked, Operation by hand lever. Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tape etc.of following sizes. |
| 489 | 15 NB |
| 490 | 25 NB (For sprinkler test) |
| 491 | 40 NB |
| 492 | SITC ofBUTTER FLY VALVEBody - Grey Cast Iron BS EN 1561 Grade EN-GJL-250 Phosphate & painted up to size 300mm SG Iron BS EN 1563 Grade EN-GJS-400-15 Phosphate & painted for size 350mm ,Disc : Stainless Steel EN 10283 Grade 1.4408, Seat : EPDM Rubber, Stem : SS 410,Ends : Wafer Suitable to get sandwiched between flanges ANSI B16.5 #150, PN 16, Rate shall include for supply and providing companion, flanges, necessary gaskets,hot dipped galvanized nuts-bolts with double washer of following sizes. |
| 493 | 50 NB |
| 494 | 65 NB |
| 495 | 80 NB |
| 496 | 100 NB |
| 497 | 125 NB |
| 498 | 150 NB |
| 499 | SITC of Bucket Strainer (ISI marked) PN 16, MOC of Body and Cover to be of Carbon steel as per ASTM A216 Grade WCB with removable Bucket screen having 0.125 inch opening. Operating pressure of 275 psi at temperature rating of 100 0F. Flange ends class 150#, Natural Rubber with reinforcement of cotton canvas Door Face and carbon steel Fastener, Rate shall include for supply and providing companion, flanges,necessary gaskets,hot diped galvanized nuts-bolts with double washer of following sizes. |
| 500 | 80 NB |
| 501 | 150 NB |
| 502 | 200 NB |
| 503 | 250 NB |
| 504 | SITC of Strainer Y type (ISI marked) CS body with SS 304 mesh , ISI marked tested to 12 kg/ sq. cm pressure Rate quoted shall include for supply and providing with ,necessary fitting gaskets, G.I.nuts-bolts & washers of following sizes. |
| 505 | 65 NB |
| 506 | SITC of Expansion Bellows (ISI marked) (Antivibration Rubber bellows ) ofhalf circular flanges on both end with tie rod fitting , ISI marked tested to 12 kg/ sq. cm pressure. Rate quoted shall include for supply and providing with companion, flanges, necessary gaskets, H.D.G.nuts-bolts & washers for following sizes. |
| 507 | 50 NB |
| 508 | 65 NB |
| 509 | 80 NB |
| 510 | 125 NB |
| 511 | 150 NB |
| 512 | SITC ofPU coated ( red )coverPressure gauge, glycerine filled, cockburden type with 100 mm dia suitable for 0.5 torr to 20 kg/ sq.cm pressure dialto be graduated both on PSI and KG with 3/4\" end connection. The rate quoted shall include for supply with providing necessary jointing materials like siphoned tube, Teflon tape, companion barrel nipples, hex nipple, etc.of following sizes. with isolation Valve (3 pc Ball Valve, Threaded End class 800 ),application -2 nos. main pump, 2 nos. pr. switch, 2 nos for booster pump. 2 Nos for Existing hydrant and sprinkler line. |
| 513 | SITC of Pressure switch (Adjustable range) Media: Water, Temperature: 0 to 60 deg. C, Enclosure: IP66, Manual Reset Version: IP54, Contact System: SPDP, Interchangeable to other ties, Pressure Range: 1 - 10 Bar, Max Operating Pressure 16 Bar, mounting with siphoned tube along with the cabling ,termination , glanding , and cable trayfrom the pressure switch tothe electric control panel with isolation valve etc. Pressure switch shall include following accessories like cover, seal cap, setting nob, damping coil, armoured damping coil. Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tape etc. |
| 514 | SITC of Automatic air vent valve with unscrew able cover for inspection. Body and cover of brass CW617N. Corrosion-resistant polyethylene float. Nominal pressure: 12 bar. Max. operating pressure: 8 bar. Max. temperature: 115°C. Automatic venting capacity at 3 bar: 17,9 l/min. Manual venting capacity at 3 bar: 139,5 l/min . Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tape etc.of following sizes. |
| 515 | 15 NB (for pump main discharge header) |
| 516 | SITC of Bladder Type Pressure Vessel 600 Ltrs. PN 25 with cluding drain valve |
| 517 | Supply, Installation, Testing & Commissioning of Common Fire Control Panel suitable for Auto operation of abovepumps including all necessary interlocking arrangements to start/stop the pump automatically. DOL starter for Jockey Pumps and star delta starter for hydrant and sprinkler electric pumps having incoming MCCB, Bus bar, Indicating Lamps Push Buttons etc. The starter panel shall be included the remote push buttons with all necessary accessories. as per SLD with PLCand Fire NOC Requirement. |
| 518 | SITC of Local push buttons station Al die-casting, mono stable 2 push button ( start / stop) ,nonluminous facia , red and green, suitable for outdoor mounting IP55 for sump pump , connection required to the dewatering pump etc. |
| 519 | SITC of power cables XLPE insulated 1.1 KV grade, Cu conductor, Strip/wire armoured, to be laid in cable trays / cleated on slab etc. and its termination. |
| 520 | Cable size 3.5 C x50Cu, LT XLPE |
| 521 | Cable size 3.5 C x35 Sqmm Al, ArmedLT XLPE, |
| 522 | Cable size 4 C x4 sqmm Cu. ArmedLT XLPE , |
| 523 | Cable size 2 C x1.5 sq.mm Al, ArmedLT XLPE ( For Pressure Switch) |
| 524 | G.I.Earth strip for panel and pumps |
| 525 | 50 x 6 mm |
| 526 | 25 x 6 mm |
| 527 | 25 X 3 mm |
| 528 | SITC of Control cables XLPE insulated 600 V grade, Cu conductor, wire armoured, to be laid in cable trays / cleated on slab etc.and its termination |
| 529 | 10 core X 1.5 sqmm, Cu conductor, PVC insulated, PVC sheathed, armoured, cable ( from local panel of Diesel pump to Main Panel) |
| 530 | 4 core X 1.5 sqmm, Cu conductor, PVC insulated, PVC sheathed, armoured, cable (from Pressure switches to Main Panel) |
| 531 | SITC of Foot Valves with Strainer , MOC of Housing Seat and Strainer, Door, Strainer- Cast Iron IS 210 Gr. FG200 , MOC of Door Plate-Cast Iron IS 210 Gr. FG200, MOC of Hang Pin-Stainless steel 410 , Flange ends class 150#, Natural Rubber with reinforcement of cotton canvas Door Face and carbon steel Fastener,PN 16 ISI marked. Rate shall include for supply and providing companion, flanges, necessary gaskets,hot dipped galvanized nuts-bolts with double washer of following sizes. |
| 532 | 150 NB |
| 533 | SITC(Supply, Installation, testing and commissioning) of Above Ground ERW GI Pipe Class C ( as per IS: 1239)including all fittings like couplings, bends, tees, U Clamps with EPDM rubber, slip on flanges, concentric & eccentric reducersand ring gasket Gaskets. Rate shall include pipe cutting, Jointing (welding / flanged joints) along with necessary washers, nuts, bolts, as required for Complete piping work, Nuts, bolts and double plain washers & one soring washer shall behot dipped galvanized.Civil cutout is in your scope. |
| 534 | Method of Painting & Piping Work :- The pipe surfaceshallbemanually cleanedofrust / mill scales by wirebrush, Use of Whipping hammer, emery papershallbe done to clean pitted areas. Above ground piping shall be Painted with zinc chromate primer and final 2 coats of Enamel Paint “ PO-RED“. Painting material shall be low volatile organic compounds (VOC ) material. The hydrant piping shall be laid & fixed above ground. The pipes to be mounted on support structureor foundation (Stub) 300 mm average above ground with cement paint prepared by contractor OR fixed on to the wall by clamps and hardware or suspended from the ceiling / truss with angle / channel / fabricated iron supports complete with Primer & black paint .The stub height at few places may go maximum 600 mm. The clamp to be provided for fixing the pipe on the stub.Following are the piping sizes (Civil Stubs and Supports to be Quoted Separately in Item Number below). |
| 535 | 15 NB (For Air Vent) |
| 536 | 25 NB (For stair case Hose reel Connection) |
| 537 | 50 NB |
| 538 | 80 NB (For Hydrant Post and Landing valve in staircase) |
| 539 | 150 NB |
| 540 | SITC(Supply, Installation, testing and commissioning) of Below Ground GI ERW pipeClass C ( as per IS: 1239)including all fittings like couplings, bends, tees, Clamps, flanges, reducersand Gaskets. Rate shall include pipe cutting, Jointing (welding / flanged joints) along with necessary washers, nuts, bolts, as required for Complete piping work Nuts, bolts and washers shall behot dipped galvanized. |
| 541 | Method of Piping Work :-The pipe surface shallbemanually cleanedofrust / mill scales by wirebrush, use of whipping hammer, emery papershallbe done to clean pitted areas. Below ground piping shall be Painted with zinc rich primer& final 2 coats of Enamel Paint “ PO-RED“for road Crossing/Inserted hume pipe . The hydrant piping shall be laid & fixed below groundas per Typical drawing. The pipes to be buried500 mmbelow ground withwrapping & coating. The wrapping /coatingmaterial shall be of IWL02 ; 4mm thick, applied by heating to the pipe with a coat of primer in radial method with 25 mm overlap,( Excavation rate to be Quoted separately in Item Number below). Following are the piping sizes. |
| 542 | 80 NB |
| 543 | 150 NB |
| 544 | FIRE BRIGADE INLET CONNECTIONS:Providing, jointing, testing and commissioning of C.I. body 4-Way Collecting Head (ISI marked)having four gunmetal 63mm male instantaneous inlets conforming to IS:903. including1no of non-return valves , 1 no of butterfly valves and four pvc blank caps with chains for fire brigade connection tomain hydrant ring. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 545 | 150 NB |
| 546 | YARD HYDRANT POST : ( EXTERNAL ) |
| 547 | Providing, jointing, fixing, testing and commissioning ofSINGLE HEADED YARD HYDRANT (ISI marked)oblique pattern fire hydrant landing valves, gunmetal, ISI marked with 80 mm dia flanged inlet and 63 mm dia instantaneous female type lug and all accessories as per IS: 5290 ‘Type-A’ with hydrant matching flanges, gaskets, nuts and bolts .Nuts, bolts and washers Shall be hot dipped galvanized. complete in all respects. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 548 | Providing, jointing, fixing, testing and commissioning ofDOUBLE HEADED YARD HYDRANT (ISI marked)oblique pattern fire hydrant landing valves, gunmetal, ISI marked with 80 mm dia flanged inlet and 63 mm dia instantaneous female type lug and all accessories as per IS: 5290 ‘Type-A’ with hydrant matching flanges, gaskets, nuts and bolts .Nuts, bolts and washers Shall be hot dipped galvanized. complete in all respects. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 549 | Providing, fixing, testing and commissioning of FIRE HOSE CABINET (ISI marked) ( 2 Nos of hose reel ) with glass at front, IP 65 construction, fabricated in 14 gauge GI sheet with powder coated after 7 tank processand enamelled fire red brush finish with fire Hose written on front. suitable to accommodate to Fire Hose Reels, Brach pipes and Nozzle. to be fully welded in construction with hinged and lock made double front door with Chrome plated locking arrangement and partly glazed 5mm thick glass, and including Two keys of recess type and Hammer for break glass. The size of hose cabinet minimum 750x 600 x 250 mm. M.S. fabricated Supports red oxide and black painted frame for cabinet mounting with HDG. washer - nut -bolt OR wall mounted. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 550 | Providing, fixing, testing and commissioning of FIRE HOSE CABINET (ISI marked) ( 1 Nos of hose reel ) with glass at front, IP 65 construction, fabricated in 14 gauge GI sheet with powder coated after 7 tank processand enamelled fire red brush finish with fire Hose written on front. suitable to accommodate to Fire Hose Reels, Brach pipes and Nozzle. to be fully welded in construction with hinged and lock made double front door with Chrome plated locking arrangement and partly glazed 5mm thick glass, and including Two keys of recess type and Hammer for break glass. The size of hose cabinet minimum 450x 600 x 250 mm. M.S. fabricated Supports red oxide and black painted frame for cabinet mounting with HDG. washer - nut -bolt OR wall mounted. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 551 | Providing, fixing, testing and commissioning of 63mm dia x 15 mts long flexible RRL (Rubber reinforced Lining) (ISI marked) type with 100% synthetic yarn & ISI marked hose including gunmetal male and female instantaneous type coupling with ISI marked(IS: 636) machine wound complete in all respect. This is to be mounted inside hose cabinet. |
| 552 | Providing, fixing, testing and commissioning ofNozzles, MOC - gun metal:63 mm dia short branch pipe (Reducing Dia) with 20 mm dia nozzle ISI marked as per (IS: 903)to be mounted on discharge end of hose reel. |
| 553 | SITC of 3 pieceBALL VALVE Floating design screwed ends A 105 Body , SS 304 ball, PTFE seat, SS 304 Stem,Class 800 ISI marked, Operation by hand lever. Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tape etc.of following sizes. |
| 554 | 15 NB (For Air Vent in main hydrant ring) |
| 555 | 25 NB (For Internal hose reel Isolation) |
| 556 | SITC ofBUTTER FLY VALVEBody - Grey Cast Iron BS EN 1561 Grade EN-GJL-250 Phosphate & painted up to size 300mm SG Iron BS EN 1563 Grade EN-GJS-400-15 Phosphate & painted for size 350mm ,Disc : Stainless Steel EN 10283 Grade 1.4408, Seat : EPDM Rubber, Stem : SS 410,Ends : Wafer Suitable to get sandwiched between flanges ANSI B16.5 #150, PN 16, Rate shall include for supply and providing companion, flanges, necessary gaskets,hot dipped galvanized nuts-bolts with double washer of following sizes. |
| 557 | 50 NB |
| 558 | 65 NB |
| 559 | 80 NB |
| 560 | 150 NB (For Wet riser connection)- 2 from pump header |
| 561 | Excavation and back filling, debris shifting in Soft Soil for Above Pipes and Hose cabinet errection, Rate to be quoted for Excavation & Backfilling complete. Pipes to be laid about 500 mm below ground level. |
| 562 | Excavation and back filling, debris shifting in Hard Murum for Above Pipes and Hose cabinet errection,, Rate to be quoted for Excavation & Backfilling complete. Pipes to be laid about 500 mm below ground level. |
| 563 | Providing, fixing, testing and commissioning ofHose Reel Drum Swinging Wall / column mounted type, GI Hose reelP.O. red colour as per IS: 884with 25mm Screwed inlet having Hose length & size: 20mm X 30mtr. length Thermo plastic hoses as per IS: 12585, ISI marked withSS ¾”Shut off Nozzle. Production Plant Area / wet riser. The hose reel drum shall be properly mounted and aligned w.r.t. wall / column. The fabricated support , anchor , fastener , clamps and HDG nut bolt , washer shall be part of scope. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 564 | Manual swing type ,MOC GI with end connection ¾\" , drum dia = 483 mm (19\"), suitable for winding hose length of 30 Mtrs. |
| 565 | SITC of Automatic air vent valve with unscrew able cover for inspection. Body and cover of brass CW617N. Corrosion-resistant polyethylene float. Nominal pressure: 12 bar. Max. operating pressure: 8 bar. Max. temperature: 115°C. Automatic venting capacity at 3 bar: 17,9 l/min. Manual venting capacity at 3 bar: 139,5 l/min . Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tape etc.of following sizes. |
| 566 | 15 NB (In main hydrant ring) |
| 567 | 15 NB (In wet riser main header) |
| 568 | Confirming to IS:2190 SITC of ABC Type fire extinguishers of following capacity at different location as per norGI. This shall be complete with standard discharge valve with tube CI bracket for wall / columnmounting with anchor - fastener or fabricated supportetc. (ISI MARKED )with signboard indicating the type, method of use ,tested details etc. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 569 | capacity of 2 kg |
| 570 | capacity of 4 kg |
| 571 | capacity of 9 kg |
| 572 | Confirming to IS:2190 SITC of 4 KG DCP fire extinguishers (As per 13849 ) of following capacity at different location as per norGI. This shall be complete with standard discharge valve with tube CI bracket for wall / columnmounting with anchor - fastener or fabricated supportetc. (ISI MARKED )with signboard indicating the type, method of use ,tested details etc. at panel room. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 573 | Confirming to IS:2190 SITC of CO2 Type fire extinguishers (As per IS 2878 ) of following 6 Kg capacity at different location as per norGI. This shall be complete with standard discharge valve with tube CI bracket for wall / columnmounting with anchor - fastener or fabricated supportetc. (ISI MARKED )with signboard indicating the type, method of use ,tested details etc. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 574 | Confirming to IS:2190 Supply, installing of fire buckets ( As per IS 2546) of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white insideand red outsideandblackon the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing GI stand duly painted over a coat of primer and enamel paint. Application- attransformer yard, DG yard. Florescent type ( should glow in darkness)Indication stickers to be provided in various relevant location. rate shouldinclusive in this section. |
| 575 | Florescent type ( should glow in darkness)Indication stickers(As Per IS:9457 for Safety colour and Safety, IS:12349 for Fire Protection Safety Signs, IS:12407 for Graphics symbols for Fire Protection Plan.) like DANGER ,NO SMOKING , EXIT ,FIRE ESCAPE,EXSTINGUSHERS ,HYDRANT, ARROWHEAD DIRECTION ,PUMP NAME on panel and PRESSURE SWITCH NO. ,HYDRANT POST BOX ,etc.to be provided. Also board \" DO AND DONT\" to be provided in various relevant location. The letter size as specify in the tender. |
| 576 | Supply, erection of Florescent type ( should glow in darkness) emergency telephone numbers like \"police\", \"fire brigade\", hospital\", \"doctors\", & \"responsible persons of the office\", should be displayed in security cabin, reception area. The letter size as specify in the tender. |
| 577 | Supply, unloading, lifting, store and installation on fabricated support of water Priming Tank capacity of 1000 litres. The shall be sintex type, single wall type, cubical shape, black colour, top opening etc. The cutout required for pipe connections and drain nozzle with isolation valve is included in this item. |
| 578 | Fabrication Job: As and when required on Site for installation of various hydrant components, for the entire sprinkler system, Wet riser cum down comer system, supports for pipe / pipe rack in the pump room / for external hydrant ring/ internal ring etc. The Supports like Angles, channels, fabricated structural etc. shall be Painted with coat of primer and Blackpaint. NOTE: This includes fabrication require for entire system ( Fire Hydrant+ Wet riser cum down comer+ Sprinkler system). |
| 579 | Testing,Commissioning and demonstration of entire fire hydrant system as per liasoning /approvalAuthority with hands andtraining to thecompany relevant staff ,security , maintenance People etc. |
| 580 | Liasoning and approval and receiving of final fire NOC from chief fire authority . |
| 581 | SITC (Supply, Installation, testing and commissioning) of Above Ground ERW GIpipeClass C ( as per IS: 1239)including all fittings likecouplings, bends, tees, U Clamps with EPDM rubber, slip on flanges, concentric & eccentric reducersand ring gasket Gaskets. Rate shall include pipe cutting, Jointing (welding / flanged joints) along with necessary washers, nuts, bolts, as required for Complete piping work. Nuts, bolts and washers shall behot dipped galvanized. The supports shall be used for clamping and support sprinkler header and sub branch to ceiling/wall/column. civil cutout is in your scope. |
| 582 | Method of Painting & Piping Work :- The pipe surfaceshallbemanually cleanedofrust / mill scales by wirebrush, Use of Whipping hammer, emery papershallbe done to clean pitted areas. Above ground piping shall be Painted with zinc chromate primer and final 2 coats of Enamel Paint “ PO-RED“.Painting material shall be low volatile organic compounds (VOC ) material. The Sprinkler piping shall be laid & fixed above ground as per Typical drawing. The pipes to be mounted on ceiling/wall/column or fixed on to the wall by clamps and hardware or suspended from the ceiling / truss with angle / channel / fabricated iron supports complete with Primer & black paint . Following are the piping sizes (Supports to be Quoted Separately in Item Number below). |
| 583 | 25 NB (Sprinkler system sub branches)- In office floor |
| 584 | 32 NB (Sprinkler system sub branches)- In office floor |
| 585 | 40 NB |
| 586 | 50 NB |
| 587 | 100 NB (Sprinkler system branch header at each floor) |
| 588 | 150 NB (Sprinkler system branch header at each floor) |
| 589 | SITC of 3 pieceBALL VALVE Floating screwed ends A 105 Body , SS 304 ball, PTFE seat, SS 304 Stem,Class 800 ISI marked, Operation by hand lever. Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tape etc.of following sizes. |
| 590 | 15 NB (For Air vent at main sprinkler header) |
| 591 | 25 NB (For Air vent at each floor) |
| 592 | SITC ofBUTTER FLY VALVEBody - Grey Cast Iron BS EN 1561 Grade EN-GJL-250 Phosphate & painted up to size 300mm SG Iron BS EN 1563 Grade EN-GJS-400-15 Phosphate & painted for size 350mm ,Disc : Stainless Steel EN 10283 Grade 1.4408, Seat : EPDM Rubber, Stem : SS 410,Ends : Wafer Suitable to get sandwiched between flanges ANSI B16.5 #150, PN 16, Rate shall include for supply and providing companion, flanges, necessary gaskets,hot dipped galvanized nuts-bolts with double washer of following sizes. |
| 593 | 50NB |
| 594 | 65NB |
| 595 | 80 NB |
| 596 | 100 NB ( For isolation of Sprinkler system branch header at each floor) |
| 597 | 100 NB ( For isolation of HVWS System) |
| 598 | 150 NB (For main header delivery line from pump room) |
| 599 | SITC of Automatic air vent valve with unscrewable cover for inspection. The Body and cover of brass CW617N. Corrosion-resistant polyethylene float. Nominal pressure: 12 bar. Max. operating pressure: 8 bar. Max. temperature: 115°C. Automatic venting capacity at 3 bar: 17,9 l/min. Manual venting capacity at 3 bar: 139,5 l/min . Rate shall include for supply and providing companion barrel nipples, hex nipple, Teflon tapeof following sizes. |
| 600 | 15 NB (For Air vent at main sprinkler header) |
| 601 | 15NB (For Air vent at each floor) |
| 602 | SITC of water flow switches (Vane type) including tamper switch and accessories, complete with tap off socket arrangement as required, withpotentialfreecontact: 150 NB pipe size. |
| 603 | SITC of Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer\"s specifications complete as required. The Valve must be UL Listed Size: 150 NB |
| 604 | SITC of Control Valve with turbine type Deluge Valves to be connected with control valve, drain & test valve and all other necessary components as per manufacturer\"s specifications complete as required. The Valve must be UL Listed Size: 100NB |
| 605 | Providing & fixing of Glass bulb type sprinklers(UL approved) .The material shall be of chrome plated cast bronze / forged bronze body of 15 mm dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type & temperature rating shall be as follows. The specification are as follows.Minimum Operating Pressure: 7 bar Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (14 bar).Thread size: 1/2 \" NPTNominal K-Factor: 80Operating Temperature=68 deg.C |
| 606 | Pendent type Sprinklers (For Office Area) |
| 607 | upright type Sprinklers (For Office Area) |
| 608 | SITC offlexible breaded hose for sprinkler including all fittings like couplings bends, tees, Clamps, flanges. Gaskets, including cutting, welding / flanged joints necessary washers, nuts, bolts, L- brackets or S- brackets , ratchets plates in case of false ceiling , supporting arrangement above false ceiling with all other required accessoriesto be connected with header branch/sub branch and sprinkler unit for following pipe sizes. The make must be UL Listed. |
| 609 | Assembly length 700 mm (1 by 1/2 ) |
| 610 | Assembly length 1000 mm (1 by 1/2 ) |
| 611 | Assembly length 1500 mm (1 by 1/2 ) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail