Supply Installation Testing Commissioning Of Split Type Air-Conditioner In Various Room Of Nsut East Campus, Geeta Colony, During The Year 2021-22
Tender Value
19.54 Lakhs
Estimated cost
Bid Submission
02 May 2022
0 days left
EMD
39080
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Supply Installation Testing Commissioning Of Split Type Air-Conditioner In Various Room Of Nsut East Campus, Geeta Colony, During The Year 2021-22
BOQ
| Sl. No. | Item Description |
| 1 | 1 SITC of 1.5 Tr capacity air conditioner, 3 star rated Non Inverter type having cooling facility suitable for operation of 215±10 % volt, 50 HZ, A.C supplywith eco friendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification..(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater. The work shall be completed as per the scope of work, terms & conditions and the Directions of Engineer-in-charge.) |
| 2 | 2 SITC of 1.0 Tr capacity air conditioner, 3 star rated Non Inverter type having cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supplywith ecofriendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater. The work shall be completed as per the scope of work, terms & conditions and the Directions of Engineer-in-charge.) |
| 3 | 3 Supplying, Installation and welding the copper pipe with the existing pipe of 1.5 TR refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping insidethe room shall be properly supported with M. S. hanger / angles / clamping arrangement, dash fasteners suitably run on existing cable tray etc. as required. |
| 4 | 4 SITC of 1/1.5TR AC Outdoor unit powder coated standrequired as per site condition wall / Floor Mounted. |
| 5 | 5 Supplying and Laying of one number 3 core 1.5/2.5 sqmm pvc insulated and pvc sheathed round wire on wall/surface/with refrigerant pipe etc for AC. |
| 6 | 6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on walla 25 mm nominal outer dia Pipes |
| 7 | 7 Comprehensive Annual Maintenance of1/1.5 Tr capacity Inverter type Split AC as per manufacturer recommendation including servicing of the AC ,Refrigerant gas charging , replacement of compressor, motor,wiring,etc complete with all parts required for healthy and proper functioning of the Air Conditioning.(Nothing will be provided by the department during the period)a) Year 1 (after Defect Liability Period of One Year) |
| 8 | b) Year 2 |
| 9 | c) Year 3 |
| 10 | d) Year 4 |
| 11 | e) Year 5 |
| 12 | 8 Dismantaling & Buyback of old and defective Air- conditioners at NSUT campusa) 1.5 Tr capacity Window type air conditioner |
| 13 | b) 1.5 Tr capacity Split type air conditioner |
| 14 | 9 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 15 | 10 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthingas required. |
AI Tender Summary
Tender Timeline
Apr 25, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMay 02, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 02, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender