Supply, Installation, Testing And Commissioning Of Pump Set With All Enm Equipment At Meethapur Booster Pumping Station Of Badarpur Ac-53.- 1 Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to ha, Delhi-Delhi

Delhi Jal Board-DJB has published Supply, Installation, Testing And Commissioning Of Pump Set With All Enm Equipment At Meethapur Booster Pumping Station Of Badarpur Ac-53.- 1 Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to ha. Submission Date for this Tender is 09-05-2022. Coats and Jackets Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

31968495
Supply, Installation, Testing And Commissioning Of Pump Set With All Enm Equipment At Meethapur Booster Pumping Station Of Badarpur Ac-53.- 1 Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to ha
Open Tender
Indian
Delhi
Delhi
09-05-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Pump Set With All Enm Equipment At Meethapur Booster Pumping Station Of Badarpur Ac-53.- 1 Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to handle potable water. The pump should have following duties :- Discharge Capacity :- 63 LPS, Duty Head :- 40 Mtrs., Speed :- 1440 RPM, Material of Construction, Casing :- CI, Shaft :- Stainless Steel EN-8, Impeller :- CI, Sleeve:- SS-410, Wear ring :- CI, Make: Mather & Plate / Kirloskar/Jyoti/DJB approved 2 Supply of 50 HP 1500 RPM (Syn) squirrel cage induction motor suitable to operate on 400±10% Volt, 3Ph , 50Hz , Horizontal foot mounted confirming to IEC:60034-1 (SOR item code: 3.2.16) Make:- ABB/ Kirloskasr/ Jyoti/ Crompton/ DJB approved 3 Supply of MS Base frame, flexible tyre coupling, coupling guard suitable for above pump sets. 4 Supply of 50 HP 1500 RPM (Syn) squirel cage induction motor suitable to operate on 400±10% Volt, 3Ph , 50Hz , Horizontal foot mounted (SOR item code: 3.2.16), Make:- ABB/ Kirloskasr/ Jyoti/ Crompton/ DJB approved 5 LT Starter Panel comprising of following :- Incomer consisting of following :- 1 no. automatic Phase Sequence Correcting Power Switch Circuit with a provision for manual operation : 250 Amps 4P, 415 VAC 50 Hz Make:-L&T/ ABB/ Schneider/ Siemens/ Socomec/ HP ,1 no. MCCB TP 250 Amps 36 kA Thermal Magnetic with adjustable Trip Setting for Overload and Short Circuit Protection Make:-Siemens/ L&T/ ABB/ Schneider , 1 No. voltmeter with VSS 0-500 VAC Digital Type 96mm X 96mm Make:- Rishabh/ AE/ L&T/Schneider , 1 No. ammeter with ASS 0 - 250 Amps Digital type 96mm X 96mm Make:- Rishabh/AE/L&T/Schneider , 1 No. energy Meter (KwHr) Digital Type CT operated Class 0.5 Make:- Rishabh/AE/L&T/Schneider, 3 Nos. CT 250 / 5 Amps Class : 0.5 for metering Make:- Kappa / AE , 1 No. CT 250 / 5 Amps for Power Factor Control Make:- Kappa / AE , 3 Set R Y B Indication Make:- Teknic / L&T / ABB / Schneider , 3 Set On / Off / Trip Indication Make:-Teknic / L&T / ABB / Schneider , 1 No. CBCT based Earth Fault Protection System to trip the MCCB in case of Earth Fault, Make:- Prok Devices / Elmeasure / Siemens / Schneider / ABB / L&T , 1. No Earth Fault Trip Indication suitable for operation of 2P/set Make:- Teknic / L&T / ABB / Schneider. Control consisting of following :- 1 No.Transformer 415 VAC / 220VAC 500 VAMake:- Logicstat / Eq ,2 Nos. Control MCB DP 10 Amps Make:- Siemens/L&T/ABB/Schneider , 1 No. Control On Indication Make:- Teknic / L&T / ABB / Schneider. Starter Section consisting of following :- 50 HP Star / Delta Starter (1W + 1S) with following total material for both - 2 Nos. MCCB TP 36 kA Motor Duty Suitable for 50 HP Make :- Siemens/L&T/ABB/Schneider, 4 Nos. Contactor TP 95 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Contactor TP 63 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/Schneider, 2 Nos. Thermal Over Load Relay 45-63 Amps Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 4 Set Start / Stop PB Make:- Teknic / L&T / ABB / Schneider, 4 Set On / Off / Trip Indication Make:- Teknic / L&T / ABB / Schneider, 4 Nos. Star / Delta Timer Make:- Siemens/L&T/ABB/Schneider. DOL Starter up to 5 H.P for 2 nos. P/set. having 2 No. MCB TP 16 Amps Make:- Siemens /L&T /ABB/Schneider , 1 No. Contactor 16 Amps TP 230 VAC Make:- Siemens /L&T /ABB/Schneider , 1 No. Overload Relay 2.8 - 4 Amps Make:- Siemens /L&T / ABB/Schneider , 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 2 Set Start / Stop PB Make:- Siemens/L&T/ABB/Schneider , 2 Set On / Off / Trip Indication Make:- Teknic / L&T / ABB / Schneider. Lighting Section having 4 Nos. 10 Amps SP MCB for lights/Fans etc Make:-Siemens/ L&T/ ABB/Schneider. Power Factor Section of 50 KVAR APFC System having 1 No. MCCB TP 160 Amps Thermal Magnetic 36 kA for APFC section isolation Make:- Siemens/L&T/ABB/Schneider , 1 No. Microprocessor based APFC Relay 6 Steps Make:- Epcos / L&T / ABB / Beluk , 4 Nos. Capacitor Heavy Duty MPP 10 KVAR 415 VAC Make:- Epcos / L&T / ABB / Beluk , 4 Nos. Capacitor Duty Contactor suitable for 20 KVAR or higher 220 VAC Make:- Siemens/L&T/ABB/Schneider , 4 Nos. MCB TP 40 Amps Make:- Siemens/L&T/ABB/Schneider , 4 Nos. Auto / Manual Selector Switch with LED Indication Make:- Teknic / L&T / ABB / Schneider , 8 Set Start / Stop PB in manual mode Make:- Teknic / L&T / ABB / Schneider , 2 Nos. Capacitor Heavy Duty MPP 5 KVAR 415 VAC Make:- Epcos / L&T / ABB / Beluk , 2 Nos. Capacitor Duty Contactor suitable for 10 KVAR or higher 220 VAC Make:- Siemens/L&T/ABB/Schneider , 2 Nos. MCB TP 20 Amps Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Auto / Manual Selector Switch with LED Indication Make:- Teknic / L&T / ABB / Schneider , 4 Set Start / Stop PB in manual mode Make:- Teknic / L&T / ABB / Schneider. Miscellaneous Material having 1 No. Bus Bar with heak shrinkable sleeves Make:- Hindalco / EC Grade with certificate , 1 No. Powder Coated Panel Enclosure with accessories Make:- DJB Approved , 1 No. Control wire. Make:- DJB Approved , 1 No. Power Wire. Make:- DJB Approved , 1 No. Dismantling of existing panel, 1 No. Delivery and installation of new panel, 1 No. Lugs / Glands as required for connections. 6 Supply of PVC insulated PVC sheathed armound aluminium conductor power cable 1.1 KV as per IS-1554 ( Part-I) of following sizes :- 3½ Corex 120 mm² (SOR item code: 18.2.6) Make : Grandley / Gloster/DJB approved 7 Supply of PVC insulated on armoured single core flexible cooper cable for working voltage upto 1.1 KV as per IS:694/2010 of size 35 mm Sq., Make : Grandley / Gloster/DJB approved 8 Supply of CI Sluice Valves non rising with SS spindle ISI PN 1.0 IS 14846 flanged end of following sizes :- 200 mm dia. 9 Supply of CI Sluice Valves non rising with SS spindle ISI PN 1.0 IS 14846 flanged end of following sizes :- 150 mm dia. 10 Supply of CI non return valve without bypass swing type IS:5312 flange end of 150 mm dia. (SOR item code: 4.9.7) Make:- Kirloskar/ IVC/ DJB approved 11 Supply of CI foot valve swing type with strainer IS-4038 flanged of 200 mm dia. (SOR item code: 4.11.3) Make:- Kirloskar/ IVC/ DJB approved 12 Pipes & Special :- S/o M.S. Pipe of dia. 200 mm. 13 S/o M.S flange of dia. 200 mm. 14 S/o M.S. D.F.90° Bend of 200 mm dia. 15 S/o M.S. D.F.90° Bend of 150 mm dia. 16 S/o M.S. Pipe of 150 mm dia. 17 S/o M.S flange of dia. 150 mm. 18 S/o MS All flanged 200 x 200 x 200 mm dia. Tee. 19 S/o M.S All flanged 150x150x150mm dia. Tee. 20 Welding and fitting of above item as per site requirement. 21 Providing of new dewatering pump setSpecification:-Dewatering pump model type horizontal CI – casing, CI- impeller, C-40 Shaft, GM- Shaft Sleeve, gland packing duly Coupled electric motor 3.00HP/ 2.2KW 1400RPM 3PH. 415V TEFC. Make- Kirloskar/M&P/ Jyoti/ KSB/ Lubi/ Djb approved 22 Supply of 50 mm dia. GI medium class pipe of length 8 mtrs., pipe fittings like socket Elbow, Tee, union, nipple, with required fittings & base frame required for making arrangement for dewatering the water from pump house to man hole. 23 Making of RCC foundation for 2 nos. of above P/sets with all material like steel, cement, concrete & all other related civil work required to complete required size for above pump sets. 24 Supply of 3mm thick high voltage insulation mats, Size 1M X 2M. 25 Supply of Pressure gauge 150 mm dia. 0-100 PSI , GI pipe fitting , stock cock , copper tube , wooden board on the suction & delivery of each pump. One complete set of 250 mm dia. pressure gauge 0-100 PSI on main header with all fittings etc. 150 mm dia. Make:- DJB approved 26 Supply of fire extinguisher powder type 4 Kg capacity.Make:- DJB approved 27 Supply of fire bucket 9 liter capacity with stand of 4 nos. bucket Make :- DJB approved 28 Fabrication / Supply of retro reflective instruction board of size 1250 x 1000 mm made out of 40 x 40 x 6mm angle iron & 2 mm thick MS Sheet. The matter to be written on M.S. board on per the direction of engineer in charge. 29 Fabrication / Supply of retro reflective sign board made out of 40 x 40 x 6mm MS angle iron frame & 2 mm thick MS sheet & 50 mm dia. GI pipe for supporting the board. The size of board 4 mtr. X 1mtr. Including grouting of board in proper way. The board shall be duly painted & matter to be written as per the direction of engineer in charge. 30 Internal / external electrification :- Internal electrification of the pump house as detailed - Light point / fan point / exhaust fan point with 1.5 sq mm PVC insulated copper conductor cable in recess surface as required. (SOR item code: 31.1.3) Make:- Havells / Phillips / Bajaj 31 5 / 6 Amp. 3 Pin Socket Plug Point. (SOR item code: 31.23.4) Make:- Havells / Phillips / Bajaj 32 15 / 16 Amp. 3 Pin Socket Plug Point. (SOR item code: 31.23.5) Make:- Havells / Phillips / Bajaj 33 Providing & fixing 18W LED fittings including making connection as required. Make:- Havells / Phillips / Bajaj 34 Providing & fixing 45 W LED fittings including making connection as required. Make:- Havells / Phillips / Bajaj 35 Providing & fixing of GI bracket of 32 mm dia., suitable bend & shifting including fixing of bracket with MS clamp on pole on wall by grouting of both. Make:- GE / Crompton / Havells 36 Providing & fixing of MCB DB 63 Amp. Capacity in sheet metal enclosure made out of 16 SWG M.S. Sheet duly painted having insulator, aluminium link as required. Make:- GE / Crompton / Havells 37 Supply of PVC insulated PVC Sheathed armoured aluminium conductor cable of2 x 16 mm sq.. Make:- Grandley / Gloster / Havells/DJB approved 38 Supply of Ceiling Fan 1200mm sweep 39 Exhaust Fan 380 mm 40 S/o 6 mtrs. height Hot dip galvanized octagonalpoles with integral control box , MCB and cable termination arrangement with top bracket including excavation work , making foundation with cement , sand , concrete etc. complete as required. Make :- Bajaj / DJB Approved make 41 Supplying & Laying 25 mm x 5 mm GI strip at 0.50 mtr. Below ground as strip earth electrode including connection / terminating with GI nut, bolt, spring, washer etc as required. (jointing shall be done by overlapping & with 2 sets of GI nut bolt & spring washer space that 50 mm) Note:- All the electrification work shall be carried out strictly as per CPWD specification. 42 Providing / fixing of ISMB 300 x 140 mm along the length (7 mtrs.) of pump house with ISI marked triple spur geared chain pulley block with greed 80 alloy steel load chain tested to 50% overload confirming to IS- 3832 - 9087 of 2 ton capacity with overhead monorail travelling trolley with 5 mtr chain mounted on ISMB 300 x 140 approx. 7 mtr long. Make:- Indef / Morris / Avon / Hercules / Reva /DJB approved 43 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe of 2.7 mtr long etc with charcoal / coke & salt as required. 44 Making of RCC foundation for 2 nos. P/Sets with all material like steel , cement, concrete, Foundation Bolt & all other related civil work required to complete the pump house 45 Installation , testing & commissioning of all above E&M equipments , laying of pipe line, Cable as per the instruction of engineer in charge , job also includes cost of packing , cartage , painting , watch & ward & freight , insurance and minor item/Jobs required for pump house operational & Commissioning the same up to the satisfaction of engineer in charge & one year guarantee. Note:- Wherever make not mentioned the make shall be as per approved DJB List / Reputed make

Key Value

Document Fees
INR 500 /-
EMD
INR 72400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :- Supply, Installation, Testing and Commissioning of Pump Set with all E&M Equipment at Meethapur Booster Pumping Station of Badarpur AC-53.
Sl. No. Item Description
1Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to handle potable water. The pump should have following duties :- Discharge Capacity :- 63 LPS, Duty Head :- 40 Mtrs., Speed :- 1440 RPM, Material of Construction, Casing :- CI, Shaft :- Stainless Steel EN-8, Impeller :- CI, Sleeve:- SS-410, Wear ring :- CI, Make: Mather & Plate / Kirloskar/Jyoti/DJB approved
2Supply of 50 HP 1500 RPM (Syn) squirrel cage induction motor suitable to operate on 400±10% Volt, 3Ph , 50Hz , Horizontal foot mounted confirming to IEC:60034-1 (SOR item code: 3.2.16) Make:- ABB/ Kirloskasr/ Jyoti/ Crompton/ DJB approved
3Supply of MS Base frame, flexible tyre coupling, coupling guard suitable for above pump sets.
4Supply of 50 HP 1500 RPM (Syn) squirel cage induction motor suitable to operate on 400±10% Volt, 3Ph , 50Hz , Horizontal foot mounted (SOR item code: 3.2.16), Make:- ABB/ Kirloskasr/ Jyoti/ Crompton/ DJB approved
5LT Starter Panel comprising of following :- Incomer consisting of following :- 1 no. automatic Phase Sequence Correcting Power Switch Circuit with a provision for manual operation : 250 Amps 4P, 415 VAC 50 Hz Make:-L&T/ ABB/ Schneider/ Siemens/ Socomec/ HP ,1 no. MCCB TP 250 Amps 36 kA Thermal Magnetic with adjustable Trip Setting for Overload and Short Circuit Protection Make:-Siemens/ L&T/ ABB/ Schneider , 1 No. voltmeter with VSS 0-500 VAC Digital Type 96mm X 96mm Make:- Rishabh/ AE/ L&T/Schneider , 1 No. ammeter with ASS 0 - 250 Amps Digital type 96mm X 96mm Make:- Rishabh/AE/L&T/Schneider , 1 No. energy Meter (KwHr) Digital Type CT operated Class 0.5 Make:- Rishabh/AE/L&T/Schneider, 3 Nos. CT 250 / 5 Amps Class : 0.5 for metering Make:- Kappa / AE , 1 No. CT 250 / 5 Amps for Power Factor Control Make:- Kappa / AE , 3 Set R Y B Indication Make:- Teknic / L&T / ABB / Schneider , 3 Set On / Off / Trip Indication Make:-Teknic / L&T / ABB / Schneider , 1 No. CBCT based Earth Fault Protection System to trip the MCCB in case of Earth Fault, Make:- Prok Devices / Elmeasure / Siemens / Schneider / ABB / L&T , 1. No Earth Fault Trip Indication suitable for operation of 2P/set Make:- Teknic / L&T / ABB / Schneider. Control consisting of following :- 1 No.Transformer 415 VAC / 220VAC 500 VAMake:- Logicstat / Eq ,2 Nos. Control MCB DP 10 Amps Make:- Siemens/L&T/ABB/Schneider , 1 No. Control On Indication Make:- Teknic / L&T / ABB / Schneider. Starter Section consisting of following :- 50 HP Star / Delta Starter (1W + 1S) with following total material for both - 2 Nos. MCCB TP 36 kA Motor Duty Suitable for 50 HP Make :- Siemens/L&T/ABB/Schneider, 4 Nos. Contactor TP 95 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Contactor TP 63 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/Schneider, 2 Nos. Thermal Over Load Relay 45-63 Amps Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 4 Set Start / Stop PB Make:- Teknic / L&T / ABB / Schneider, 4 Set On / Off / Trip Indication Make:- Teknic / L&T / ABB / Schneider, 4 Nos. Star / Delta Timer Make:- Siemens/L&T/ABB/Schneider. DOL Starter up to 5 H.P for 2 nos. P/set. having 2 No. MCB TP 16 Amps Make:- Siemens /L&T /ABB/Schneider , 1 No. Contactor 16 Amps TP 230 VAC Make:- Siemens /L&T /ABB/Schneider , 1 No. Overload Relay 2.8 - 4 Amps Make:- Siemens /L&T / ABB/Schneider , 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 2 Set Start / Stop PB Make:- Siemens/L&T/ABB/Schneider , 2 Set On / Off / Trip Indication Make:- Teknic / L&T / ABB / Schneider. Lighting Section having 4 Nos. 10 Amps SP MCB for lights/Fans etc Make:-Siemens/ L&T/ ABB/Schneider. Power Factor Section of 50 KVAR APFC System having 1 No. MCCB TP 160 Amps Thermal Magnetic 36 kA for APFC section isolation Make:- Siemens/L&T/ABB/Schneider , 1 No. Microprocessor based APFC Relay 6 Steps Make:- Epcos / L&T / ABB / Beluk , 4 Nos. Capacitor Heavy Duty MPP 10 KVAR 415 VAC Make:- Epcos / L&T / ABB / Beluk , 4 Nos. Capacitor Duty Contactor suitable for 20 KVAR or higher 220 VAC Make:- Siemens/L&T/ABB/Schneider , 4 Nos. MCB TP 40 Amps Make:- Siemens/L&T/ABB/Schneider , 4 Nos. Auto / Manual Selector Switch with LED Indication Make:- Teknic / L&T / ABB / Schneider , 8 Set Start / Stop PB in manual mode Make:- Teknic / L&T / ABB / Schneider , 2 Nos. Capacitor Heavy Duty MPP 5 KVAR 415 VAC Make:- Epcos / L&T / ABB / Beluk , 2 Nos. Capacitor Duty Contactor suitable for 10 KVAR or higher 220 VAC Make:- Siemens/L&T/ABB/Schneider , 2 Nos. MCB TP 20 Amps Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Auto / Manual Selector Switch with LED Indication Make:- Teknic / L&T / ABB / Schneider , 4 Set Start / Stop PB in manual mode Make:- Teknic / L&T / ABB / Schneider. Miscellaneous Material having 1 No. Bus Bar with heak shrinkable sleeves Make:- Hindalco / EC Grade with certificate , 1 No. Powder Coated Panel Enclosure with accessories Make:- DJB Approved , 1 No. Control wire. Make:- DJB Approved , 1 No. Power Wire. Make:- DJB Approved , 1 No. Dismantling of existing panel, 1 No. Delivery and installation of new panel, 1 No. Lugs / Glands as required for connections.
6Supply of PVC insulated PVC sheathed armound aluminium conductor power cable 1.1 KV as per IS-1554 ( Part-I) of following sizes :- 3½ Corex 120 mm² (SOR item code: 18.2.6) Make : Grandley / Gloster/DJB approved
7Supply of PVC insulated on armoured single core flexible cooper cable for working voltage upto 1.1 KV as per IS:694/2010 of size 35 mm Sq., Make : Grandley / Gloster/DJB approved
8Supply of CI Sluice Valves non rising with SS spindle ISI PN 1.0 IS 14846 flanged end of following sizes :- 200 mm dia.
9Supply of CI Sluice Valves non rising with SS spindle ISI PN 1.0 IS 14846 flanged end of following sizes :- 150 mm dia.
10Supply of CI non return valve without bypass swing type IS:5312 flange end of 150 mm dia. (SOR item code: 4.9.7) Make:- Kirloskar/ IVC/ DJB approved
11Supply of CI foot valve swing type with strainer IS-4038 flanged of 200 mm dia. (SOR item code: 4.11.3) Make:- Kirloskar/ IVC/ DJB approved
12Pipes & Special :- S/o M.S. Pipe of dia. 200 mm.
13S/o M.S flange of dia. 200 mm.
14S/o M.S. D.F.90° Bend of 200 mm dia.
15S/o M.S. D.F.90° Bend of 150 mm dia.
16S/o M.S. Pipe of 150 mm dia.
17S/o M.S flange of dia. 150 mm.
18S/o MS All flanged 200 x 200 x 200 mm dia. Tee.
19S/o M.S All flanged 150x150x150mm dia. Tee.
20Welding and fitting of above item as per site requirement.
21Providing of new dewatering pump setSpecification:-Dewatering pump model type horizontal CI – casing, CI- impeller, C-40 Shaft, GM- Shaft Sleeve, gland packing duly Coupled electric motor 3.00HP/ 2.2KW 1400RPM 3PH. 415V TEFC. Make- Kirloskar/M&P/ Jyoti/ KSB/ Lubi/ Djb approved
22Supply of 50 mm dia. GI medium class pipe of length 8 mtrs., pipe fittings like socket Elbow, Tee, union, nipple, with required fittings & base frame required for making arrangement for dewatering the water from pump house to man hole.
23Making of RCC foundation for 2 nos. of above P/sets with all material like steel, cement, concrete & all other related civil work required to complete required size for above pump sets.
24Supply of 3mm thick high voltage insulation mats, Size 1M X 2M.
25Supply of Pressure gauge 150 mm dia. 0-100 PSI , GI pipe fitting , stock cock , copper tube , wooden board on the suction & delivery of each pump. One complete set of 250 mm dia. pressure gauge 0-100 PSI on main header with all fittings etc. 150 mm dia. Make:- DJB approved
26Supply of fire extinguisher powder type 4 Kg capacity.Make:- DJB approved
27Supply of fire bucket 9 liter capacity with stand of 4 nos. bucket Make :- DJB approved
28Fabrication / Supply of retro reflective instruction board of size 1250 x 1000 mm made out of 40 x 40 x 6mm angle iron & 2 mm thick MS Sheet. The matter to be written on M.S. board on per the direction of engineer in charge.
29Fabrication / Supply of retro reflective sign board made out of 40 x 40 x 6mm MS angle iron frame & 2 mm thick MS sheet & 50 mm dia. GI pipe for supporting the board. The size of board 4 mtr. X 1mtr. Including grouting of board in proper way. The board shall be duly painted & matter to be written as per the direction of engineer in charge.
30Internal / external electrification :- Internal electrification of the pump house as detailed - Light point / fan point / exhaust fan point with 1.5 sq mm PVC insulated copper conductor cable in recess surface as required. (SOR item code: 31.1.3) Make:- Havells / Phillips / Bajaj
315 / 6 Amp. 3 Pin Socket Plug Point. (SOR item code: 31.23.4) Make:- Havells / Phillips / Bajaj
3215 / 16 Amp. 3 Pin Socket Plug Point. (SOR item code: 31.23.5) Make:- Havells / Phillips / Bajaj
33Providing & fixing 18W LED fittings including making connection as required. Make:- Havells / Phillips / Bajaj
34Providing & fixing 45 W LED fittings including making connection as required. Make:- Havells / Phillips / Bajaj
35Providing & fixing of GI bracket of 32 mm dia., suitable bend & shifting including fixing of bracket with MS clamp on pole on wall by grouting of both. Make:- GE / Crompton / Havells
36Providing & fixing of MCB DB 63 Amp. Capacity in sheet metal enclosure made out of 16 SWG M.S. Sheet duly painted having insulator, aluminium link as required. Make:- GE / Crompton / Havells
37Supply of PVC insulated PVC Sheathed armoured aluminium conductor cable of2 x 16 mm sq.. Make:- Grandley / Gloster / Havells/DJB approved
38Supply of Ceiling Fan 1200mm sweep
39Exhaust Fan 380 mm
40S/o 6 mtrs. height Hot dip galvanized octagonalpoles with integral control box , MCB and cable termination arrangement with top bracket including excavation work , making foundation with cement , sand , concrete etc. complete as required. Make :- Bajaj / DJB Approved make
41Supplying & Laying 25 mm x 5 mm GI strip at 0.50 mtr. Below ground as strip earth electrode including connection / terminating with GI nut, bolt, spring, washer etc as required. (jointing shall be done by overlapping & with 2 sets of GI nut bolt & spring washer space that 50 mm) Note:- All the electrification work shall be carried out strictly as per CPWD specification.
42Providing / fixing of ISMB 300 x 140 mm along the length (7 mtrs.) of pump house with ISI marked triple spur geared chain pulley block with greed 80 alloy steel load chain tested to 50% overload confirming to IS- 3832 - 9087 of 2 ton capacity with overhead monorail travelling trolley with 5 mtr chain mounted on ISMB 300 x 140 approx. 7 mtr long. Make:- Indef / Morris / Avon / Hercules / Reva /DJB approved
43Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe of 2.7 mtr long etc with charcoal / coke & salt as required.
44Making of RCC foundation for 2 nos. P/Sets with all material like steel , cement, concrete, Foundation Bolt & all other related civil work required to complete the pump house
45Installation , testing & commissioning of all above E&M equipments , laying of pipe line, Cable as per the instruction of engineer in charge , job also includes cost of packing , cartage , painting , watch & ward & freight , insurance and minor item/Jobs required for pump house operational & Commissioning the same up to the satisfaction of engineer in charge & one year guarantee. Note:- Wherever make not mentioned the make shall be as per approved DJB List / Reputed make