| 1 | Repair to Desert Cooler Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint etc complete all as specified and directed by Engr- in -charge. |
| 2 | All as per item No. 1 here in before but applying one coats of synthetic enamel paint to external surfaces of desert coolers including steel grills, removing of wooden grass pad & refixing the same after necessary work side panel etc complete all asp specified. |
| 3 | Taking down carefully old unserviceable water pumps heavy duty of capacity 1/70 HP, 230 volts 50 HZ single in lieu providing new submersible type water pump including necessary wire connection etc. M Make;- Bajaj/CG/ Havells |
| 4 | Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, including replacement of mounting legs & nuts boltswith capacitor 4 Mfd as reqd at site complete all as specified and directed.Make;-Bajaj/CG/ Havells |
| 5 | Taking down carefully fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, from existing desert coolers of each camp at MFFR and refixing the same camp fan motor after rewinding with super enameled copper wire of existing size complete including replacement of bush/bearing, mounting legs & nuts boltscapacitor 4 Mfd as reqd at site complete all as specified and directed. Make: Milan/chetakNote:- Contractor will be arranged all required T&P (winding machine) repair for desert cooler motor/sevicing i.e winding/greasing /oilingin AGE MFFR yard) |
| 6 | Taking down the following parts from the existing desert coolers & providing new parts in same possition as listed below-(a) Capacitor for desert cooler 4 MFD 230 volts Make: Asian/Tibcon |
| 7 | GI sheet as per existing guage front grill including nuts bolts and washers suitable for 18/20\" sweep desert coolers including necessary wire connection, regulator & on/off switch etc reqd at site, Make-Alka/kinark. |
| 8 | Taking down following old part of desert cooler old rusted as under and M & L out of 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required accessories for fixing etc complete(a) Bottom tank as existing size |
| 9 | Top cover as existing size |
| 10 | Side panels size- set of three |
| 11 | Wood wool pad for desert coolers (set of three) |
| 12 | Supporting jali for desert coolers (set of three) |
| 13 | Plug Top 3 pin, 5-A, 230 Volt |
| 14 | Plug Top 3 pin, 15-A, 230 Volt |
| 15 | Fan blades made of aluminium for desert cooler as per sample |
| 16 | Cable, 3 core, copper conductor size 23/0.0076 for desert cooler. Make: plaza/finolex/kalinga |
| 17 | Supply only condenser 2.5 MFD |
| 18 | Replacement of PVC pipe 15mm for desert cooler including all necessary \"T\" joints & clamps reqd at site |
| 19 | Distributor of PVC for desert cooler with fixing bolt |
| 20 | Replacement of Elbow of PVC for desert cooler |
| 21 | S&F in repair tap mounting with nipple 1/2\" as per sample. |
| 22 | S&F in repair water outlet nipple with washers and check nuts (copper/brass) |
| 23 | Taking down unserviceable compressor from deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing deep freezers of capacity 320 ltr, Make: voltas/Usha/Sidhwal/Blue star complete all as directed. |
| 24 | Supply and fixing compressor suitable for deep freezer 320 ltr make- Blue star/Gulmarg/Usha, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips. |
| 25 | Supply and fixing compressor suitable for deep freezer 405 ltr make- Blue star, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips. |
| 26 | Cleaning of complete deep freezer existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing deep freezer of 320 /405 ltrs capacity of make and model as per existing complete all as specified and as directed. |
| 27 | Water CoolerTaking down unserviceable compressor form deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing water coolers ofMake: voltas/Usha/Sidhwal/Blue star 60/120,150/180. |
| 28 | Supply and fixing new hermetically sealedunit (compressor) of following Makes and model including provision of new bushes,grommets, sleeves , washers, mounting rubers nuts boltes,terminals,covers,brasing and clips in the existing Water coolers 60/120 Ltrs Make :-Blue star /usha /voltas with necessary accessaries and all as directed. |
| 29 | all as per item No. 28 here in before butfor 150/180ltrs capacitycompleteall as specied and as directed by engr -in-charge. |
| 30 | Taking down carefully existing internal wiring of existing water coolers and in liu provision of new internal wiring of with PVC insulated copper conducter cable of size 40/ 0.0076 sq mm including replacementof main lead 03 meter long, terminals clips, thimbles, 03 pin plug top 15 amps & soldering extra compelte all as specified. Make :- of wiring plaza/finolex |
| 31 | Cleaning of completeexisting gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing water cooler complete all as specified and directed. |
| 32 | Removing of old rusted warn out portion of sheet/angle/flat iron from base, front and top etc. of the water cooler/ air conditioner and providing new mild steel sheet, angle iron/MS flat including necessary bending, welding. reveting etc. including making provision for mounting of fan motors, compressor, and condenser complete all as specified. |
| 33 | Complete removing old faded paint from steel surfaces of water cooler by scrapers making the surface smooth including filing material and painting the surface of any description over 10 Cm in width of girth not otherwise described with one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed. |
| 34 | Taking down deffective fan motor from water coolers, dismentling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size. Make : Milan/Chetak including replacement of shaft, boshes, mounting rubbers, nuts, bolts and refixing after reassembling and testing in existing water cooler for under mentioned fan motors :- (Note : The unit rate coated shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers, insulating materials and clams)Fan motors of capacity 1/16 HP 230 Volts single phase. |
| 35 | Fan motors of capacity 1/32 HP 230 Volts single phase. |
| 36 | Fan motors of capacity 1/35 HP 230 Volts single phase. |
| 37 | fan blade made out of aluminium as per sample |
| 38 | Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed. |
| 39 | Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/16 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed. |
| 40 | Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/10 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed. |
| 41 | Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/25 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed. |
| 42 | S & F push cock (stainlees steel) for water cooler as per sample existing. |
| 43 | S & F thermostat for water cooler as per sample existing. |
| 44 | S & F relay with OLP suitable for water cooler existing as per sample. |
| 45 | S & F runing capacitor 36 MFD. Make : Tibcon/Sharda/Epcos |
| 46 | S & F runing capacitor 60/80 MFD. Make : Tibcon/Sharda/Epcos |
| 47 | S & F runing capacitor 80/100 MFD. Make : Tibcon/Sharda/ Epcos |
| 48 | S & F runing capacitor 100/120 MFD. Make : Tibcon/Sharda/ Epcos |
| 49 | S & F runing capacitor 10MFD. Make : Tibcon/Sharda/Epcos |
| 50 | S & F runing capacitor 15MFD. Make : Tibcon/Sharda/Epcos |
| 51 | S & F runing capacitor 40/60 MFD. Make : Tibcon/Sharda/Epcos |
| 52 | Cable, 3 core, copper conductor size 40/0.0076 for water cooler. Make: plaza /finolex/kalinga |
| 53 | Taking down unserviceable compresor 2TR capacity from the window/split AC of any make and supply and fixing new compresor 2 Ton capacity of including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips from existing AC complete all as specified and as directed. |
| 54 | All as per srl Item No. 53 here-in before but for window type AC 1.5 TR capacity of any make as per existing. |
| 55 | Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing window/split type air conditioner of 1.5/2 TR capacities of make and model as per existing complete all as specified and directed. |
| 56 | Taking down unserviceable fan motor of any capacity from the window type air conditioner 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing guage and size including heat varnishes replacement of shaft, bearing and bush complete all as found unserviceable after opening complete all as specified and required and as directed. |
| 57 | Removing of existing window/split type AC 1.5/2 Ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and refixing on mounting including provn for making opening air tight and dust proof including testing and commissioning complete all as directed. |
| 58 | S & F running capacitor 45 MFD Make : Tibcon/Sharda/Epcos |
| 59 | S & F running capacitor 60 MFD Make : Tibcon/Sharda/Epcos |
| 60 | S & F running capacitor 50 MFD Make : Tibcon/Sharda/Epcos |
| 61 | S & F PCB (Printed Circuit Board) of window/split type capacity 1.5/2 Ton all as specified and as directed. |
| 62 | Replacement of remote control of 1.5/2 Ton window/split type AC of any make/type all as specified and as directed. |
| 63 | Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing and complete overhoauling of AC 1.5/2 ton capacity all as specified: -Note- Accessories/parts paid saperately under relevent items |
| 64 | PVC filters for AC (window/split) |
| 65 | Contactor for split AC |
| 66 | Starting relay for AC |
| 67 | Replacement of burnt out transformer and S&F new transformer of 3 or 4 KVA voltage stabilizer of any make.:\"V\" guard |
| 68 | Taking down unserviceableindoor unit ofsplitAC capacity 1.5 TR fromexisting place and supply and fix new indoor unit of split AC 1.5 TR capacity of includingmounting frame withnuts, bolts in existing place complete all as specified and as directed. Make :- Sumsung |
| 69 | Taking downunserviceable Exhaust roolerofsplitAC capacity2.0 TR fromexisting place and supply and fix new Exhaust rooler of split AC 1.5 TR capacity of includingbush/bearingas per existing type complete accessories fix in existing place complete all as specified and as directed. Make :- Sumsung |
| 70 | Taking downunserviceable out door unit ofsplitAC capacity 1.5 TR fromexisting place and supply and fix new indoor unit of split AC 1.5 TR capacity of includingmounting frame withnuts, bolts and complete accessories fix in existing place complete all as specified and as directed. Make :- Sumsung |
| 71 | Supply and laying PVC insulated stranded aluminium conductor cable heavy duty1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 06 Sqmm 2 core nominal cross section incl remove unserviceable cable complete all as specified. Make -(Asian Cable Co./Finolex/Polycab) |
| 72 | Ceiling FanTaking down ceiling fan for repair/servicing i.e. winding/greasing/oiling etc., 1200/1400 mm sweep, of any make and any type model, ceiing cable end with tape, dismandling the blades, removing fan and deposit the blades/motor to store for repairing/servicing complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be taking down ceiling fan of each camp in MFFR and carrying with saftey deposit for repair/sevicing i.e winding/greasing /oiling in AGE MFFR yard andcamp wise marked each fan by permnent markerand informed to JE E/M) |
| 73 | M&L re-winding of ceiling fan of size 1200/1400 mm sweep with super enameled copper winding wire of gauge as per existing size/No of wire conforming to IS, including varnishing the motor windings with best quality varnish, capacitor 2.5 Mfd and fixing the same place complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be arranged all required T&Prepair for ceiling fan/sevicing i.e winding/greasing /oilingin AGE MFFR yard) |
| 74 | S&F in replacement of ball bearing of size/No. 6201 conforming to IS complete all as specified and as directed by Engineer-in-charge. |
| 75 | S&F in replacement of ball bearing of size/No. 6202 conforming to IS complete all as specified and as directed by Engineer-in-charge. |
| 76 | S&F in replacement of ball bearing of size/No. 6203 conforming to IS complete all as specified and as directed by Engineer-in-charge. |
| 77 | S&F in replacement of brass bush suitable for ceiling fan of any make and model conforming to IS complete all as specified and as directed by Engineer-in-charge |
| 78 | S&F in replacement ofShaft suitable for ceiling fan as per existing size and shape complete all as specified and as directed by Engineer-in-charge |
| 79 | S&F fabricated down rod made out of 15mm dia MS pipe medium duty 60cm long including nut, bolt, & washer etc and including drilling holes on top and bottom fan fixing with fan hooks and ceiling respectively as required suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge. |
| 80 | S&F D clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge. |
| 81 | S&F PVC canopies (set of two) as required at site and as directed by Engineer in charge. |
| 82 | S&F condenser 2.5 MFD conforming to IS complete all as specified and as directed by Engineer-in-charge. |
| 83 | S & F of flexible wire of size 23/.0076 stranded copper conductor complete all as specified and directed by Engr -in-charge. |
| 84 | S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement including taking down old regulator complete all as specified and as directed by Engineer-in-charge. |
| 85 | Taking down and dismantling of exhaust fan 250 mm/350 mm/450 mm sweep of any make and model, opening the cover, separating the rotor and startor assembly, locating the fault and maing the fan in fully serviceable condition including replacing the defected worn out screw, flexible wire size 23/0.0076, oiling/greasing the fan and re-assembling the samd and testing complete to the entire satisfaction of Engineer-in-charge. |
| 86 | Re-winding of exhaust fan 250 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish, capacitor and fixing the same place complete all as specified and as directed by Engineer-in-charge. Note:- Contractor will be arranged all required T&Prepair for exhaust fan/sevicing i.e winding/greasing /oilingin AGE MFFR yard) |
| 87 | Ditto all as per item No. 86 here in above but of size 350 mm sweep complete all as specified and as directed by Engineer-in-charge. |
| 88 | Ditto all as per item No. 86 here in above but of size 450 mm sweep complete all as specified and as directed by Engineer-in-charge. |
| 89 | S&F in replacement of blades suitable size for exhaust fan 250 mm duly approved by Engineer in charge complete all as specified and as directed by Engineer-in-charge. |
| 90 | Ditto all as per item No. 89 here in above but size of exhaust fan 350 mm sweep complete all as specified and as directed by Engineer-in-charge. |
| 91 | Ditto all as per item No. 89 here in above but size of exhaust fan 450 mm sweep complete all as specified and as directed by Engineer-in-charge. |
| 92 | Taking down unsv louver and supply and fix new louver of exhaust fan of size 300 mm complete all as specified and directed by Engr-in- charge. |
| 93 | Taking down unsv louver and supply and fix new louver of exhaust fan of size 450 mm complete all as specified and directed by Engr-in- charge. |
| 94 | Supply and fixingPVC fresh air fan (Exhaust fan) of size 250/300 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and directed. Make: - Usha/Bajaj/Havells |
| 95 | Cleaning and preparation of old surface pf ciling and exhaust fan complete of any size and spray coat painting with synthetic enameled paint complete all as specified and as directed by Enge-in-charge. |