Supply, Installation, Testing And Commissioning Of Pump Set With All Enm Equipment At Meethapur Booster Pumping Station Of Badarpur Ac-53.- Supply Of Horizontal Split Casing Single Stage Pump Having Flanged Suction & Delivery And Suitable To Handle Potable Water. The Pump Should Have Following Duties :- Discharge Capacity :- 63 Lps, Duty Head :- 40 Mtrs., Speed :- 1440 Rpm, Material Of Construction, Casing :- Ci, Shaft :- Stainless Steel En-8, Impeller :- Ci, Sleeve:- Ss-410, Wear Ring :- Ci, Make: Mather & Plate / Kirloskar / Jyoti / Djb Approved 2 Supply Of 50 Hp 1500 Rpm ( Syn ) Squirrel Cage Induction Motor Suitable To Operate On 400±10% Volt, 3Ph , 50Hz , Horizontal Foot Mounted Confirming To Iec:60034-1 ( Sor Item Code: 3.2.16 ) Make:- Abb / Kirloskasr / Jyoti / Crompton / Djb Approved 3 Supply Of Ms Base Frame, Flexible Tyre Coupling, Coupling Guard Suitable For Above Pump Sets. 4 Supply Of 50 Hp 1500 Rpm ( Syn ) Squirel Cage Induction Motor Suitable To Operate On 400±10% Volt, 3Ph , 50Hz , Horizontal Foot Mounted ( Sor Item Code: 3.2.16 ) , Make:- Abb / Kirloskasr / Jyoti / Crompton / Djb Approved 5 Lt Starter Panel Comprising Of Following :- Incomer Consisting Of Following :- 1 No. Automatic Phase Sequence Correcting Power Switch Circuit With A Provision For Manual Operation : 250 Amps 4P, 415 Vac 50 Hz Make:-L&T / Abb / Schneider / Siemens / Socomec / Hp , 1 No. Mccb Tp 250 Amps 36 Ka Thermal Magnetic With Adjustable Trip Setting For Overload And Short Circuit Protection Make:-Siemens / L&T / Abb / Schneider , 1 No. Voltmeter With Vss 0-500 Vac Digital Type 96Mm X 96Mm Make:- Rishabh / Ae / L&T / Schneider , 1 No. Ammeter With Ass 0 - 250 Amps Digital Type 96Mm X 96Mm Make:- Rishabh / Ae / L&T / Schneider , 1 No. Energy Meter ( Kwhr ) Digital Type Ct Operated Class 0.5 Make:- Rishabh / Ae / L&T / Schneider, 3 Nos. Ct 250 / 5 Amps Class : 0.5 For Metering Make:- Kappa / Ae , 1 No. Ct 250 / 5 Amps For Power Factor Control Make:- Kappa / Ae , 3 Set R Y B Indication Make:- Teknic / L&T / Abb / Schneider , 3 Set On / Off / Trip Indication Make:-Teknic / L&T / Abb / Schneider , 1 No. Cbct Based Earth Fault Protection System To Trip The Mccb In Case Of Earth Fault, Make:- Prok Devices / Elmeasure / Siemens / Schneider / Abb / L&T , 1. No Earth Fault Trip Indication Suitable For Operation Of 2P / Set Make:- Teknic / L&T / Abb / Schneider. Control Consisting Of Following :- 1 No.Transformer 415 Vac / 220Vac 500 Vamake:- Logicstat / Eq , 2 Nos. Control Mcb Dp 10 Amps Make:- Siemens / L&T / Abb / Schneider , 1 No. Control On Indication Make:- Teknic / L&T / Abb / Schneider. Starter Section Consisting Of Following :- 50 Hp Star / Delta Starter ( 1W + 1S ) With Following Total Material For Both - 2 Nos. Mccb Tp 36 Ka Motor Duty Suitable For 50 Hp Make :- Siemens / L&T / Abb / Schneider, 4 Nos. Contactor Tp 95 Amps Ac3 Duty 220 Vac Make:- Siemens / L&T / Abb / Schneider , 2 Nos. Contactor Tp 63 Amps Ac3 Duty 220 Vac Make:- Siemens / L&T / Abb / Schneider, 2 Nos. Thermal Over Load Relay 45-63 Amps Make:- Siemens / L&T / Abb / Schneider , 2 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 4 Set Start / Stop Pb Make:- Teknic / L&T / Abb / Schneider, 4 Set On / Off / Trip Indication Make:- Teknic / L&T / Abb / Schneider, 4 Nos. Star / Delta Timer Make:- Siemens / L&T / Abb / Schneider. Dol Starter Up To 5 H.P For 2 Nos. P / Set. Having 2 No. Mcb Tp 16 Amps Make:- Siemens / L&T / Abb / Schneider , 1 No. Contactor 16 Amps Tp 230 Vac Make:- Siemens / L&T / Abb / Schneider , 1 No. Overload Relay 2.8 - 4 Amps Make:- Siemens / L&T / Abb / Schneider , 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 2 Set Start / Stop Pb Make:- Siemens / L&T / Abb / Schneider , 2 Set On / Off / Trip Indication Make:- Teknic / L&T / Abb / Schneider. Lighting Section Having 4 Nos. 10 Amps Sp Mcb For Lights / Fans Etc Make:-Siemens / L&T / Abb / Schneider. Power Factor Section Of 50 Kvar Apfc System Having 1 No. Mccb Tp 160 Amps Thermal Magnetic 36 Ka For Apfc Section Isolation Make:- Siemens / L&T / Abb / Schneider , 1 No. Microprocessor Based Apfc Relay 6 Steps Make:- Epcos / L&T / Abb / Beluk , 4 Nos. Capacitor Heavy Duty Mpp 10 Kvar 415 Vac Make:- Epcos / L&T / Abb / Beluk , 4 Nos. Capacitor Duty Contactor Suitable For 20 Kvar Or Higher 220 Vac Make:- Siemens / L&T / Abb / Schneider , 4 Nos. Mcb Tp 40 Amps Make:- Siemens / L&T / Abb / Schneider , 4 Nos. Auto / Manual Selector Switch With Led Indication Make:- Teknic / L&T / Abb / Schneider , 8 Set Start / Stop Pb In Manual Mode Make:- Teknic / L&T / Abb / Schneider , 2 Nos. Capacitor Heavy Duty Mpp 5 Kvar 415 Vac Make:- Epcos / L&T / Abb / Beluk , 2 Nos. Capacitor Duty Contactor Suitable For 10 Kvar Or Higher 220 Vac Make:- Siemens / L&T / Abb / Schneider , 2 Nos. Mcb Tp 20 Amps Make:- Siemens / L&T / Abb / Schneider , 2 Nos. Auto / Manual Selector Switch With Led Indication Make:- Teknic / L&T / Abb / Schneider , 4 Set Start / Stop Pb In Manual Mode Make:- Teknic / L&T / Abb / Schneider. Miscellaneous Material Having 1 No. Bus Bar With Heak Shrinkable Sleeves Make:- Hindalco / Ec Grade With Certificate , 1 No. Powder Coated Panel Enclosure With Accessories Make:- Djb Approved , 1 No. Control Wire. Make:- Djb Approved , 1 No. Power Wire. Make:- Djb Approved , 1 No. Dismantling Of Existing Panel, 1 No. Delivery And Installation Of New Panel, 1 No. Lugs / Glands As Required For Connections. 6 Supply Of Pvc Insulated Pvc Sheathed Armound Aluminium Conductor Power Cable 1.1 Kv As Per Is-1554 ( Part-I ) Of Following Sizes :- 3½ Corex 120 Mm² ( Sor Item Code: 18.2.6 ) Make : Grandley / Gloster / Djb Approved 7 3 Corex 70 Mm² ( Sor Item Code: 18.1.8 ) Make : Grandley / Gloster / Djb Approved 8 Supply Of Ci Sluice Valves Non Rising With Ss Spindle Isi Pn 1.0 Is 14846 Flanged End Of Following Sizes :- 200 Mm Dia. 9 Supply Of Ci Sluice Valves Non Rising With Ss Spindle Isi Pn 1.0 Is 14846 Flanged End Of Following Sizes :- 150 Mm Dia. 10 Supply Of Ci Non Return Valve Without Bypass Swing Type Is:5312 Flange End Of 150 Mm Dia. ( Sor Item Code: 4.9.7 ) Make:- Kirloskar / Ivc / Djb Approved 11 Supply Of Ci Foot Valve Swing Type With Strainer Is-4038 Flanged Of 200 Mm Dia. ( Sor Item Code: 4.11.3 ) Make:- Kirloskar / Ivc / Djb Approved 12 Pipes & Special :- S / O M.S. Pipe Of Dia. 200 Mm. 13 S / O M.S Flange Of Dia. 200 Mm. 14 S / O M.S. D.F.90° Bend Of 200 Mm Dia. 15 S / O M.S. D.F.90° Bend Of 150 Mm Dia. 16 S / O M.S. Pipe Of 150 Mm Dia. 17 S / O M.S Flange Of Dia. 150 Mm. 18 S / O Ms All Flanged 200 X 200 X 200 Mm Dia. Tee. 19 S / O M.S All Flanged 150X150x150mm Dia. Tee. 20 Welding And Fitting Of Above Item As Per Site Requirement. 21 Providing Of New Dewatering Pump Setspecification:-Dewatering Pump Model Type Horizontal Ci – Casing, Ci- Impeller, C-40 Shaft, Gm- Shaft Sleeve, Gland Packing Duly Coupled Electric Motor 3.00Hp / 2.2Kw 1400Rpm 3Ph. 415V Tefc. Make- Kirloskar / M&P / Jyoti / Ksb / Lubi / Djb Approved 22 Supply Of 50 Mm Dia. Gi Medium Class Pipe Of Length 8 Mtrs., Pipe Fittings Like Socket Elbow, Tee, Union, Nipple, With Required Fittings & Base Frame Required For Making Arrangement For Dewatering The Water From Pump House To Man Hole. 23 Making Of Rcc Foundation For 2 Nos. Of Above P / Sets With All Material Like Steel, Cement, Concrete & All Other Related Civil Work Required To Complete Required Size For Above Pump Sets. 24 Supply Of 3Mm Thick High Voltage Insulation Mats, Size 1M X 2M. 25 Supply Of Pressure Gauge 150 Mm Dia. 0-100 Psi , Gi Pipe Fitting , Stock Cock , Copper Tube , Wooden Board On The Suction & Delivery Of Each Pump. One Complete Set Of 250 Mm Dia. Pressure Gauge 0-100 Psi On Main Header With All Fittings Etc. 150 Mm Dia. Make:- Djb Approved 26 Supply Of Fire Extinguisher Powder Type 4 Kg Capacity.Make:- Djb Approved 27 Supply Of Fire Bucket 9 Liter Capacity With Stand Of 4 Nos. Bucket Make :- Djb Approved 28 Fabrication / Supply Of Retro Reflective Instruction Board Of Size 1250 X 1000 Mm Made Out Of 40 X 40 X 6Mm Angle Iron & 2 Mm Thick Ms Sheet. The Matter To Be Written On M.S. Board On Per The Direction Of Engineer In Charge. 29 Fabrication / Supply Of Retro Reflective Sign Board Made Out Of 40 X 40 X 6Mm Ms Angle Iron Frame & 2 Mm Thick Ms Sheet & 50 Mm Dia. Gi Pipe For Supporting The Board. The Size Of Board 4 Mtr. X 1Mtr. Including Grouting Of Board In Proper Way. The Board Shall Be Duly Painted & Matter To Be Written As Per The Direction Of Engineer In Charge. 30 Internal / External Electrification :- Internal Electrification Of The Pump House As Detailed - Light Point / Fan Point / Exhaust Fan Point With 1.5 Sq Mm Pvc Insulated Copper Conductor Cable In Recess Surface As Required. ( Sor Item Code: 31.1.3 ) Make:- Havells / Phillips / Bajaj 31 5 / 6 Amp. 3 Pin Socket Plug Point. ( Sor Item Code: 31.23.4 ) Make:- Havells / Phillips / Bajaj 32 15 / 16 Amp. 3 Pin Socket Plug Point. ( Sor Item Code: 31.23.5 ) Make:- Havells / Phillips / Bajaj 33 Providing & Fixing 18W Led Fittings Including Making Connection As Required. Make:- Havells / Phillips / Bajaj 34 Providing & Fixing 45 W Led Fittings Including Making Connection As Required. Make:- Havells / Phillips / Bajaj 35 Providing & Fixing Of Gi Bracket Of 32 Mm Dia., Suitable Bend & Shifting Including Fixing Of Bracket With Ms Clamp On Pole On Wall By Grouting Of Both. Make:- Ge / Crompton / Havells 36 Providing & Fixing Of Mcb Db 63 Amp. Capacity In Sheet Metal Enclosure Made Out Of 16 Swg M.S. Sheet Duly Painted Having Insulator, Aluminium Link As Required. Make:- Ge / Crompton / Havells 37 Supply Of Pvc Insulated Pvc Sheathed Armoured Aluminium Conductor Cable Of2 X 16 Mm Sq.. Make:- Grandley / Gloster / Havells / Djb Approved 38 Supply Of Ceiling Fan 1200Mm Sweep 39 Exhaust Fan 380 Mm 40 S / O 6 Mtrs. Height Hot Dip Galvanized Octagonalpoles With Integral Control Box , Mcb And Cable Termination Arrangement With Top Bracket Including Excavation Work , Making Foundation With Cement , Sand , Concrete Etc. Complete As Required. Make :- Bajaj / Djb Approved Make 41 Supplying & Laying 25 Mm X 5 Mm Gi Strip At 0.50 Mtr. Below Ground As Strip Earth Electrode Including Connection / Terminating With Gi Nut, Bolt, Spring, Washer Etc As Required. ( Jointing Shall Be Done By Overlapping & With 2 Sets Of Gi Nut Bolt & Spring Washer Space That 50 Mm ) Note:- All The Electrification Work Shall Be Carried Out Strictly As Per Cpwd Specification. 42 Providing / Fixing Of Ismb 300 X 140 Mm Along The Length ( 7 Mtrs. ) Of Pump House With Isi Marked Triple Spur Geared Chain Pulley Block With Greed 80 Alloy Steel Load Chain Tested To 50% Overload Confirming To Is- 3832 - 9087 Of 2 Ton Capacity With Overhead Monorail Travelling Trolley With 5 Mtr Chain Mounted On Ismb 300 X 140 Approx. 7 Mtr Long. Make:- Indef / Morris / Avon / Hercules / Reva / Djb Approved 43 Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories & Providing Masonry Enclosure With Cover Plate Having Locking Arrangement & Watering Pipe Of 2.7 Mtr Long Etc With Charcoal / Coke & Salt As Required. 44 Making Of Rcc Foundation For 2 Nos. P / Sets With All Material Like Steel , Cement, Concrete, Foundation Bolt & All Other Related Civil Work Required To Complete The Pump House 45 Installation , Testing & Commissioning Of All Above E&M Equipments , Laying Of Pipe Line, Cable As Per The Instruction Of Engineer In Charge , Job Also Includes Cost Of Packing , Cartage , Painting , Watch & Ward & Freight , Insurance And Minor Item / Jobs Required For Pump House Operational & Commissioning The Same Up To The Satisfaction Of Engineer In Charge & One Year Guarantee. Note:- Wherever Make Not Mentioned The Make Shall Be As Per Approved Djb List / Reputed Make