Construction Of Water Storage Tank At 10Th Rac Bn Office Campus Bikaner.
Tender Value
16.90 Lakhs
Estimated cost
Bid Submission
10 May 2022
0 days left
EMD
33800
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
bikaner → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Water Storage Tank At 10Th Rac Bn Office Campus Bikaner.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation over areas (exceeding 30 cm in depth, 1.5 Mtr. in width as well as 10 Sqm on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5 Mtr. disposed earth to be leveled and neatly dressed : All kinds of soil |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.:-1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 3 | Centering & Shuttering with plywood or steel sheets including strutting, propping, bracing bothways and removal of formwork for foundations in basements rafts, footings, strap beams bases of columns, etc. upto plinth level. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing, compaction, finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement - All work up to plinth level : 1 : 1 : 2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size |
| 5 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints excluding cost of centering shuttering and reinforcement : 1 : 1 : 2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge . All works upto floor Five floorM20 grade Design Mix |
| 7 | Addextrafor providing richermixes respectively at all floor levels |
| 8 | Providing M-25 grade concreteinstead ofM-20 grade design mix. |
| 9 | Providing M-30 grade concrete instead ofM-20 grade design mix. |
| 10 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. :-Thermo-mechanically Treated bars (Tata, SAIL) |
| 11 | Centering & shuttering with plywood or steel sheets including strutting, propping, bracing bothways with wooden members and removal of formwork for superstructure upto 4.5 m height above plinth, for : Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 12 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for : |
| 13 | Suspended floors, roofs landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintel, beam etc. |
| 14 | Brick masonry in Super structure with bricks of class designation 75 in : Cement mortar 1 : 6 (1 cement : 6 coarse sand). |
| 15 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 16 | Extra if square,rectangular hollow tubelarsections are used or grill made by flats only |
| 17 | Providing and fixing M.S. sheet single leaf door shutter in angle iron frame 35 x 35 x 5 mm suitabilly diagonally braced with 25 x 3 mm flat iron above and below lock rail of size 50 x 5 mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats : including two coats of anit-corrasite red oxide primer paint.M.S. Sheet 18 S.W.G. |
| 18 | Plaster on new surface on wall in cement sand mortar1 : 3 including raking of joints etc. complete finefinish : 20 mm thick |
| 19 | Plaster on new surface on walls in cement sand mortar 1 : 6 including racking of joint etc. complete fine finished : |
| 20 | 12 mm thick |
| 21 | 20 mm thick |
| 22 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound@ 0.253 kg/sqm.b) laying secondlayer of Fiber glass clothwhen the first layer is still green. Overlaps of joints of fiber cloth should not be less than 10 cm .c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/sqm mixed with water proffing cement compound@ 0.670kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all aroundd) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured |
| 23 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) |
| 24 | P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete. |
| 25 | SupplyingandfixingFerro- cementcoverwithC.I.frameforchambers&manholes of size. |
| 26 | 450mm dia, 5Kg. C.I. frameto with stand 3 MT center point load & minimum unfracturedload of 1 MT. (Light duty). |
| 27 | Grading roof water proofing treatment with : Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
| 28 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 29 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 30 | Providing and fixing G.I. pipes (External Work) with G.I. fittings (IS : 1239 Mark) including trenching & refilling earth etc. |
| 31 | 50 mm dia nominal bore |
| 32 | 65 mm dia nominal bore |
| 33 | 80mm dia nominal bore |
| 34 | 15mm dia nominal bore |
| 35 | 20mm dia nominal bore |
| 36 | 25mm dia nominal bore |
| 37 | 32mm dia nominal bore |
| 38 | 40mm dia nominal bore |
| 39 | Providing and fixing Full -way Valve (IS : 778 Mark) or wheel valve of approved make. |
| 40 | Gun-metal 50mm nominal bore. |
| 41 | Gun-metal 65mm nominal bore. |
| 42 | Gun-metal 80mm nominal bore. |
| 43 | Gun-metal 15mm nominal bore. |
| 44 | Gun-metal 20mm nominal bore. |
| 45 | Gun-metal 25mm nominal bore. |
| 46 | Gun-metal 32mm nominal bore. |
| 47 | Gun-metal 40mm nominal bore. |
| 48 | Providing and fixing Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 1000 gm 25 mm |
| 49 | Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : |
| 50 | 15mm dia nominal bore |
| 51 | 20mm dia nominal bore |
| 52 | 25mm dia nominal bore |
| 53 | 32mm dia nominal bore |
| 54 | 40mm dia nominal bore |
| 55 | 50mm dia nominal bore |
| 56 | 65mm dia nominal bore |
| 57 | 80mm dia nominal bore |
| 58 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed within a lead of 50 Mtr.Pipes cables etc. not exceeding 80 mm dia |
| 59 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding : New work (Three or more coats). |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work. |
| 61 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 62 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 63 | ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite,grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazedtilesandMATfinishedtiles. (6.90% of Item 35) |
| 64 | ExtraforusingGreater size of glazed tiles andMAT finishedtiles up to 300x450 mm size (17.69% of item 35) |
| 65 | SITC of Monoblock submersible motor pump sets ISI marked (IS:8034-1989) of approved make with required accessories including making connection suitable for Open well. Undergound water tank The job includes lowering ofriser pipe, G.I./H.D.P.E. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. Make-Crompton greaves,Texmo, KSB, |
| 66 | 5.0 HP, 3-Ø, (120-220)Mtr, (100-38)LPM |
| 67 | Supply and fixing of Oil / Air break Starter panel made out of sheet steelpowder coated enclosure comprising of over load protection relay, short circuit & single phasing protection, ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc. complete in all respect suitable for following rating motors.Group-1 ( Make L&T, Siemens, ABB, BCH,) |
| 68 | For Three phase Submersible / Mono block pump |
| 69 | 3.0 HP to 10.0 HP ( DOL ) |
| 70 | P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.Group-1 (Make-Polycab,Paramount,Plaza) |
| 71 | 35.0 Sq.mm |
| 72 | 3.5 core |
| 73 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make.Outer Dia. / Inner dia.Group-1 |
| 74 | 50/55 mm |
| 75 | P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing ,phophatised ,powder painted complete with insulated suitable ratingcopper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. |
| 76 | Double door with Provision of Incomer MCCB 100 / 125 A Rating |
| 77 | 4 Way |
| 78 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Group-1 |
| 79 | Triple pole MCB |
| 80 | 6 A to 32 A rating |
| 81 | SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required.Group-1 |
| 82 | With Thermal Magnetic release |
| 83 | up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 84 | P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required. |
| 85 | 4.0 Sq.mm 3 core flat / Round |
AI Tender Summary
Tender Timeline
Apr 21, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMay 10, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 11, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender