01 Preventive Maintenance Of Motor Up To 15Kw Preventive Maintenance Of Motor Up To 15Kw: Scope Of Work Includes Maintenance Of Motors After Feeder Isolation Checking Tightness Of Terminal, Cleaning Of Terminal, Checking Of Fan, Fan Cover, Earthing Et, ganjam-Odisha

Indian Rare Earths Limited-IREL has published 01 Preventive Maintenance Of Motor Up To 15Kw Preventive Maintenance Of Motor Up To 15Kw: Scope Of Work Includes Maintenance Of Motors After Feeder Isolation Checking Tightness Of Terminal, Cleaning Of Terminal, Checking Of Fan, Fan Cover, Earthing Et. Submission Date for this Tender is 09-05-2022. Motor Work Tenders in ganjam Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

31904969
01 Preventive Maintenance Of Motor Up To 15Kw Preventive Maintenance Of Motor Up To 15Kw: Scope Of Work Includes Maintenance Of Motors After Feeder Isolation Checking Tightness Of Terminal, Cleaning Of Terminal, Checking Of Fan, Fan Cover, Earthing Et
Open Tender
Indian
Odisha
ganjam
09-05-2022

Tender Details

01 Preventive Maintenance Of Motor Up To 15Kw Preventive Maintenance Of Motor Up To 15Kw: Scope Of Work Includes Maintenance Of Motors After Feeder Isolation Checking Tightness Of Terminal, Cleaning Of Terminal, Checking Of Fan, Fan Cover, Earthing Etc. 2 02 Preventive Maintenance Of Motor Above 15Kw Preventive Maintenance Of Motor Above 15Kw Up To 45Kw: Scope Of Work Includes Maintenance Of Motors After Feeder Isolation, Checking Tightness Of Terminal, Cleaning Of Terminal, Checking Of Fan, Fan Cover, Earthing Etc. 3 03 Preventive Maintenance Of Motor Above 45Kw Preventive Maintenance Of Motor Above 45Kw: Scope Of Work Includes Maintenance Of Motors After Feeder Isolation Checking Tightness Of Terminal, Cleaning Of Terminal, Checking Of Fan, Fan Cover, Earthing Etc. 4 04 Preventive Maintenance Of Mcc Feeder Preventive Maintenance Of Mcc Feeder: Scope Of Work Includes Blowering And Cleaning Of Feeders After Isolation. Checking Of Terminal Tightness Of Feeder Components. Repair / Replacement The Faulty Component Like Power / Aux Contactor, Control Mcb, Overload Relay Or Terminal Blocks If Required. 5 05 Preventive Maintenance Of Lighting Feeder Preventive Maintenance Of Lighting Feeder: Scope Of Work Includes Blowering And Cleaning Of Feeders After Isolation. Checking Of Terminal Tightness Of Feeder Components. Repair Or Replacement The Faulty Component Like Isolator, Fuse Base, Timer Etc If Required. 6 06 Preventive Maintenance Of Lighting Distribution Board Preventive Maintenance Of Lighting Distribution Board: Scope Of Work Includes Blowering And Cleaning Of Ldb. Checking Terminal Tightness Of Ldb. Repair Or Replacement The Faulty Component Like Mcb, Timer, Contactor, Coil Etc If Required. 7 07 Maintenance Of Light Fittings Maintenance Of Light Fittings: Maintenance Of Light Fitting Includes Maintenance Of Hpmv, Mh, Fluorescent, Hpsv, And Led Fitting. Scope Of Work Includes Tightening Of Terminals, Replacement Of Lamp, Choke, Igniter, Capacitor, Starter, Holder, Terminal Block, Surge Arrester, Driver, Led Assembly / Panel, Rectification Of Loose Connection And Any Work Which Is Related To Rectification Of Fitting For Bringing Back To Operation. 8 08 Maintenance Of Fan Maintenance Of Fan: Fan Means Single Phase Or Three Phase Ceiling, Pedestal, Exhaust, Wall Mounting Fans. Scope Of Work Includes Tightening, Replacement Of Capacitor, Bearing, Blades, Terminal Block, Switch And Any Other Work Related To Rectification Of Fan For Bringing Back Into Operation. 9 09 Preventive Maintenance Of Heating Elements Preventive Maintenance Of Heating Elements 1 Kw To 6 Kw: Scope Of Work Includes Cleaning Of Terminals, Application Of Electrical Contact Cleaner, Tightening Of Terminals 10 10 Preventive Maintenance Of Local Control Station Preventive Maintenance Of Local Control Station: Scope Of Work Includes Cleaning, Tightening Of Terminals, And Replacement Of Components If Required 11 11 Preventive Maintenance Of Dol Starter Preventive Maintenance Of Dol Starter: Cleaning Of Starter, Checking Of Terminal Tightness. Repair / Replacement The Faulty Component Like Contactor, Overload Relay If Required. 12 12 Preventive Maintenance Of Star Delta Starter Preventive Maintenance Of Star Delta Starter: Cleaning Of Starter, Checking Of Terminal Tightness. Repair / Replacement The Faulty Component Like Contactor, Overload Relay, Timer If Required. 13 13 Shift Complaint / Job Attended Shift Complaint / Job Attended: Scope Of Work Includes Complaints Or Job Related To Troubleshooting Of Mcc Feeder, Motors, Hts, Eps, Irms, Hirms, Redms, Rerms, And Ensuring Continuous Availability Of Electrical Equipment For Plant Production. Job Also Includes Removal And Re Installation Of Fuse, Taking Energy Reading, Measurement Of Current, Checking Of Electrode Voltage Of Hts, Eps Checking Of Magnetic Field Intensity. It Also Includes Any Miscellaneous Electrical Work Assigned By Eic. 14 14 Laying Of Cable Laying Of Cable Up To 4.0Sqmm Copper / Aluminum Cable Or Wire Of Any Core Armoured Or Unarmoured: Scope Of Work Includes Shifting Of Cables From Central Stores Or From Any Other Location And Laying Of Cable Over Cable Trays And Binding Of The Cable On The Cable Trays By Gi Wire Or Cable Tie Or Through Gi Conduit On Supports. Up To & Including 4 Sqmm Up To Copper / Aluminum Cables ( Single Core / Multicore Armoured And Unarmoured Cable ) 15 15 Laying Of Cable Laying Of Cable Above 4.0Sqmm Up To 50 Sqmm Copper / Aluminum Cable Of Any Core Armoured Or Unarmoured: Scope Of Work Includes Shifting Of Cables From Central Stores Or From Any Other Location And Laying Of Cable Over Cable Trays And Binding Of The Cable On The Cable Trays By Gi Wire Or Cable Tie Or Through Gi Conduit On Supports. Above 4 Sqmm Up To & Including 50 Sqmm Copper / Aluminum Cables ( Single Core / Multicore Armoured And Unarmoured Cable ) 16 16 Fixing Of Push Botton Station / Dol Starter / Mcb Box / Pull Cord Switch / Limit Switch / Distribution Board / Junction Box / Sfu Fixing Of Push Botton Station / Dol Starter / Mcb Box / Pull Cord Switch / Limit Switch / Distribution Board / Junction Box / Sfu: Scope Of Work Includes Includes Issue Of Items From Stores, Storing In Safe Location And Fixing The Item On The Desired Location As Per The Direction Of Eic Using Proper Frame And Nut & Bolts. Structural Steel, Nut Bolt Etc Shall Be Provided By Irel For Fabrication And Welding Of Frame. Party Has To Arrange Welding Electrode, Welding Machine, Gas Cutting Set, Safety Goggles, Gloves Etc For Work 17 17 Preventive Maintenance Of Local Panels Preventive Maintenance Of Local Panels Like Hts, Redms, Rerms, Eps, Air Table, Irms, Hirms, Heater Etc Panels. Blowering And Cleaning Of Feeders After Isolation. Checking Of Terminal Tightness Of Feeder Components. Repair / Replacement The Faulty Component Like Power / Aux Contactor, Control Mcb, Overload Relay Or Terminal Blocks If Required.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document