Repair Maintenance Of Led Security Street Lights And Other Connected Items In Txr And Domestic Area At Sonegaon- Phase - I & Phase Ii ( From Sl Item No. 1 To 12 ) Removing Old Pattern Single / Three Phase Electric Meteranddepositedto Age E / M Store Comp, Nagpur-Maharashtra

Military Engineer Services-MES has published Repair Maintenance Of Led Security Street Lights And Other Connected Items In Txr And Domestic Area At Sonegaon- Phase - I & Phase Ii ( From Sl Item No. 1 To 12 ) Removing Old Pattern Single / Three Phase Electric Meteranddepositedto Age E / M Store Comp. Submission Date for this Tender is 14-05-2022. Bolts Tenders in Nagpur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

31895717
Corrigendum : Repair Maintenance Of Led Security Street Lights And Other Connected Items In Txr And Domestic Area At Sonegaon- Phase - I & Phase Ii ( From Sl Item No. 1 To 12 ) Removing Old Pattern Single / Three Phase Electric Meteranddepositedto Age E / M Store Comp
Open Tender
Indian
Maharashtra
Nagpur
14-05-2022

Tender Details

Repair Maintenance Of Led Security Street Lights And Other Connected Items In Txr And Domestic Area At Sonegaon- Phase - I & Phase Ii ( From Sl Item No. 1 To 12 ) Removing Old Pattern Single / Three Phase Electric Meteranddepositedto Age E / M Store Complete All As Specified And Directed. Note :Last Meter Reading Shall Be Noted By The Contractor And Submitted To Bso & Age E / M Cme. 2 Supply And Installation Ofsmart Single Phase Meter With The Following Specifications: ( A ) Ac Single Phase Two Wire, Tamper Proof, Static Meter Of Class 1.0, 240 V, 50 Hz, 10 A-60 A Conforming To Is-16444 And Relevant Iec Standards With Inbuilt 865-867 Mhz Radio Frequency Communication Facility With Self Healing Mesh Network With Default And On Demand Display, Billing Data Generation Facility, Anti-Tamper Features, Microprocessor And Led / Lcd Based Circuitry. ( B ) Meter Should Support The Following Data : 30 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, 30 Load Survey Data For Energy, Monthly Billing Survey For Cumulative Energy And Max Demand ( C ) Meter Should Have Connect / Disconnect Functionality Operable From Billing Software ( D ) The Meter Should Support Open Communication Protocol Dlmswith The Softwaremake :- L&T Cat No. Wm101bc7dlpr6inn Or Equivalent In Secure Meters / Schneider 3 …..Ditto…. All As Per Sl Item No.2 Above, But As Repeater 4 Supply And Installation Ofthree Phase Meter With The Following Specifications: ( A ) Ac Three Phase Four Wire, Tamper Proof, Static Meter Of Class 1.0, 415 V, 50 Hz, 10 A-60 A Conforming To Is-16444 And Relevant Iec Standards With Inbuilt 865-867 Mhz Radio Frequency Communication Facility With Self Healing Mesh Network With Default And On Demand Display, Billing Data Generation Facility, Anti-Tamper Features, Microprocessor And Led / Lcd Based Circuitry. ( B ) Meter Should Support The Following Data : 30 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, 30 Load Survey Data For Energy, Monthly Billing Survey For Cumulative Energy And Max Demand ( C ) Meter Should Have Connect / Disconnect Functionality Operable From Billing Software ( D ) The Meter Should Support Open Communication Protocol Dlmswith The Softwaremake : L&T Cat No. Wr300bc73lpr6 Or Equivalent Of Secure Meters / Schneider 5 Supply And Installation Of Ip-67 Protection Data Concentrator Units ( Dcu ) Compatible For Remote Automatic Metering Infrastructure ( Ami ) Solution And Capable Of Communicating With The Smart Energy Meter In The Corresponding Frequency Band And With The Data Server Through Gprs / Ethernet. It Would Have Internal Memory To Store Data Of At Least 200 Modules. It Would Have Inbuilt Battery Back-Up. It Would Have Ip-67 Protection. It Would Support Auto Discovery Of The Meters And Self Healing Mechanism For The Breaks In The Rf Network.Make: L&T, Secure Meters, Schneider, Cyanconnnode 6 Supply And Installation Ofsmart Single Phase Meter With The Following Specifications: ( A ) Ac Single Phase Two Wire, Tamper Proof, Static Meter Of Class 1.0, 240 V, 50 Hz, 10 A-60 A Conforming To Is-16444 And Relevant Iec Standards With Inbuilt 4G Modem With Default And On Demand Display, Billing Data Generation Facility, Anti-Tamper Features, Microprocessor And Led / Lcd Based Circuitry. ( B ) Meter Should Support The Following Data : 30 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, 30 Load Survey Data For Energy, Monthly Billing Survey For Cumulative Energy And Max Demand ( C ) Meter Should Have Connect / Disconnect Functionality Operable From Billing Software ( D ) The Meter Should Support Open Communication Protocol Dlmswith The Softwaremake:Cat No.Wm101bc7dsm4ginn Of L&T Or Equivalent Of Secure Meters / Schneider 7 Supply And Installation Ofthree Phase Meter With The Following Specifications: ( A ) Ac Three Phase Four Wire, Tamper Proof, Static Meter Of Class 1.0, 415 V, 50 Hz, 10 A-60 A Conforming To Is-16444 And Relevant Iec Standards With Inbuilt 4G Modem With Default And On Demand Display, Billing Data Generation Facility, Anti-Tamper Features, Microprocessor And Led / Lcd Based Circuitry. ( B ) Meter Should Support The Following Data : 30 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, 30 Load Survey Data For Energy, Monthly Billing Survey For Cumulative Energy And Max Demand ( C ) Meter Should Have Connect / Disconnect Functionality Operable From Billing Software ( D ) The Meter Should Support Open Communication Protocol Dlmswith The Softwaremake :Cat No.Wr300bc83sm4ginn Of L&T Or Equivalent Of Secure Meters / Schneider 8 Supply And Configuration Of The Web Based Software Per Meter With Following Modules: ( I ) Meter Data Management Modulethe Meter Data Management Module Would Be Responsible For Collecting The Data From The Concentrator And Make The Data Available To The Billing System.The Meter Data Management System Would Capture And Provide The Following Data: ( A ) 30 Min Instantaneous Data From All The Meters For Seven Parameters – Cumulative Energy, Cumulative Apparent Energy ( As Applicable ) , Power, Current, Voltage, Power Factor And Frequency 9 ( B ) Monthly Billing Survey Data For Cumulative Energy And Max Demand ( Ii ) Billing Modulethe Billing Module Would Collect The Data From The Meter Data Management Module, Calculate The Energy Consumption, Calculate Billing Determinant And Make Energy Data / Billing Data Available To Admin And End Users. The Billing Module Would Include Functionalities For Tariff Setup, Bill Format Setup, Bill Adjustment, Occupation Billing And Vacation Billing. The System Would Be Setup As Postpaid Billing System. It Would Allow Postpaid And Prepaid Functionality As Required. 10 ( Iii ) Occupation And Vacation Modulethe System Would Support Occupation / Vacation And Billing Reports.The Software Would Be Collecting Data From Dcu. The Software Would Provide Access To Staff As Well As The Occupant For The Data. ( Iv ) Web Site: There Would Be A Dedicated Website For The Age And Bso Team To View Of All The Data And Information. The Designated Users In Mes Would Have The Admin Access To The Application. The Mes Staff Would Also Have The Access Of The Key Information On An Android Mobiles App ( For Admin Use ) . ( V ) Customer Portalthe System Would Include A Customer Portal For The Resident / Occupant To Log In And View Their Own Energy / Billing Data. There Would Be Android And Ios Mobile Apps For The User To Monitor Its Own Data And Balance On Regular Basis. 11 ( Vi ) Energy Accounting Modulethe System Would Include Features Of Energy Accounting. The System Would Be Able To Account For Total Energy Block Wise, Facility Wise And Would Also Allow Calculations Of Unaccounted Energy In Case Total Energy Meter Is Also Available. ( Vii ) Communication Modulethe System Would Provide Communication Of Energy Data And Bills Via Print, Email And Sms Methods. 12 ( Viii ) Meter Master Datathe System Would Support Meter Master Data Repository. The System Would Support Meter Replacement Process. ( Ix ) Excel Exportthe System Would Support Export Of Metering And Billing Data In Excel Format. 13 ( X ) Customer Care Module - The Software Would Include A Customer Care Module Where The User Would Be Log In Any Complaints. The Service Provider Would Monitor The Complaints And Carry Out The Necessary Activities For The Complaints Resolution. ( Xi ) Meter Installation Module - The Software Would Include An App Based Meter Installation Module Where The Meter Installation Or Changes Can Be Captured On The App Itself And The Readings May Be Demonstrated To The User If Required On The App Itself. ( Xii ) Activities Communication - The Software Support Communication Of The Various Activities Such As Occupation, Vacation, Meter Change. Personal Detail Change Etc. With The User As Well As The Department On Email.Make: Innologix, Sap, Oracle 14 Note:- ( A ) The Software Would Be Hosted On Meity ( Ministry Of Information Technology ) Approved Gcc ( Government Community Cloud ) ( B ) The Software Would Contain Two Year Defect Liability Including All Operating Expenses Such As Gprs Charges, Hosting Charges Etc. 15 M&L For Sub Main Wiring With Two Run Of4 Sqmm Single Core Multi Stranded Pvc Insulated And Unsheathed Copper Conductor ( Red For Phase And Black For Neutral ) Of Grade 1100 Volt Frlsh Cable In And Including 1100 Volt Electrical Grade Pvc Casing Capingof Desired Colour Not Less Than1.2 Mm Thick And 25 Mm Wide& Frlsh 4 Sqmm Copper Conductor Cable Pvc Unsheathed Green Coloured For Earthing With Complete Accessories Duly Connected With Earth Dolly Complete All As Specified And As Directed.Note :- Two Runs Of Cable, One Run Of Pvc Casing Capping And One Run Of Earthing Cable Together Measured As One Unit Length. 16 M&L For Sub Main Wiring With Two Run Of6 Sqmm Single Core Multi Stranded Pvc Insulated And Unsheathed Copper Conductor ( Red For Phase And Black For Neutral ) Of Grade 1100 Volt Frlsh Cable In And Including 1100 Volt Electrical Grade Pvc Casing Capingof Desired Colour Not Less Than1.2 Mm Thick And 25 Mm Wide& Frlsh 6 Sqmm Copper Conductor Cable Pvc Unsheathed Green Coloured For Earthing With Complete Accessories Duly Connected With Earth Dolly Complete All As Specified And As Directed.Note :- Two Runs Of Cable, One Run Of Pvc Casing Capping And One Run Of Earthing Cable Together Measured As One Unit Length. 17 M&L For Sub Main Wiring With Four Run Of6 Sqmm Single Core Multi Stranded Pvc Insulated And Unsheathed Copper Conductor ( Red For Phase And Black For Neutral ) Of Grade 1100 Volt Frlsh Cable In And Including 1100 Volt Electrical Grade Pvc Casing Capingof Desired Colour Not Less Than1.2 Mm Thick And 25 Mm Wide& Frlsh 6 Sqmm Copper Conductor Cable Pvc Unsheathed Green Coloured For Earthing With Complete Accessories Duly Connected With Earth Dolly Complete All As Specified And As Directed.Note :- Four Runs Of Cable, One Run Of Pvc Casing Capping And One Run Of Earthing Cable Together Measured As One Unit Length. 18 Supply, Install And Testing Lt Panel Board Wall / Stand Mounted Self Supporting Compartmentalised Design Of Suitable Size To Accommodate The Lt Switch Gears & Other Accessories Suitable For 440 Volt 3 Phase 4 Wire Made Out Of 2.0 Mm Crca Sheet Powder Coated Having Gasketed Front Two Hinged Doors With Locking Arrangement Including Bottom And Top Detachable Gland Plate Complete With Suitable Size Of Rust Proof Nuts Bolts And Washers Etc Complete With Mounting Accessories Including The Following :- ( A ) Four Copper Bus Bar 400A Mounted On Epoxy Insulators Provided With Rust Proof Nuts Bolts And Washer ( B ) Mccb Tpn Adjustable Type 250 Amps 16 Ka-1 No ( C ) Mcb Spn 63 Amps -10 Nos ( D ) Provn For Suitable Space For Electric Meter -10 Nos ( E ) Led Indicating Lamp-3 Nos ( Ryb ) ( F ) Ammeter 0-400Amps With Ct Coil And Selector Switch -01 Set ( G ) Voltmeter 0-500Volt With Selector Swtich-01 No. 19 Phase - Iiim&L For Three Year Comprehensive Maintenance Including Operating Costs After Two Years Of Defect Liability Period. The Service Would Include The Following Items: ( A ) Monthly Sim Charges For The Dcu. The Contractor Would Ensure Supply Of Appropriate Sims To Ensure Necessary Single Availability. The Contractor Would Change The Sim Or Sim Provider As Required. In Case Of Network Issues, The Contractor Would Liaison With The Telecom Service Providers For Necessary Resolution. ( B ) Recurring Sms Charges. The Sms Would Be Issued For The Payments Alerts, Low Balance Alerts And Disconnection / Connection Alerts. 20 ( C ) Software Amc. This Would Include Necessary Upgradations In The Software Such As Support To The Chrome Browser Changes, Android Version Changes , Ios Version Changes. These Changes Happen On Frequent Basis And The Software Would Support All The Changes. ( D ) Changes In The Government Tariff Structure. The Government Tariff Structure Changes May Require Software Upgrade. The Same Would Be Included In The Amc Scope Of Work. 21 ( E ) Remote Server Admin Support - Ensuring Adequate Database Back Up, Upgradations In The Operating System, Anti Virus Updates, Database Upgrade Etc. ( F ) Reports Development - The Additional Reports As Needed For The Success Of The Project Would Be Developed ( G ) Software Installation On Any Alternate / Backup Server If Required 22 ( H ) The Communication Network Monitoring And Support ( I ) Configuration Of The Repaired / Replaced Hardware In The System ( J ) Trouble Shooting And Necessary Actions To Run The System As Required. ( K ) Software Bug Fixing As And When Required

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-May-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-05-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 17000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ MAINT OF LED SECURITY/STREET LIGHTS & OTHER CONNECTED ITEMS INTXR AND DOMESTIC AREA AT SONEGAON
Sl. No. Item Description
1Taking down carefully old tube light/MH/HPSV Light fitting , 70/80/150/250/400 watt, unserviceable LED Street light fittings carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No. 2 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractor"s property as per Sch of Credit.
2Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 1 here in before complete all as specified and directed.
3(a) LED fittings 70 watt driver
4(b) LED fittings 80 watt driver
5(c) LED fittings 150 watt driver
6(d) LED fittings 200 watt driver
7Taking down carefully old security light/MH/HPSV Light fitting , unserviceableLED building security light fittings 25 watt carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.
8Supply only the spares LED fittings 20 watt driver required for replacement of spares during the process of repair of the light fitting vide SI item No 3 here in before complete all as specified and directed.
9Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
10Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
11Returning, filling inincluding spreading, levelling, watering and well ramming in layers not exceeding25 cm in soft/loose soil complete all as specified and directed.
12M & L for providing dry river sand as in sand cushioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
13Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
14M & L road cutting of size 30 cm width x 45 cm depth for laying of cables including making good the road with necessaryreturning filling and bituminious portion with concrete and bituminous mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching with the existing surfacescomplete all as specified and directed.
15Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc forprotection of cables including taking down complete all as specified and directed
16Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for the following sizes.
1750 sqmm, 3.5 core
1825 sqmm, 3.5 core
1916 sqmm, 4 core
2010 sqmm, 2 core
21S&FLED street light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 70 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-BAJAJ Cat no. ENXT P 84L WH CR PC SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI
22S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 200 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-,BAJAJ cat no. PRAZE F 240L WH NB-A5 TG SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI
23S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-,BAJAJ cat no. PRAZE F 96L WH NB-A5 TG SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI
24S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-,BAJAJ cat no. PRAZE F 180L WH NB-A5 TG SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI
25S & F 20 Watt LED Bldg security light with a nominal system.The luminaire shall have rated system lifetime of50,000 burning hours at L70.The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70.The luminaire shall meet IP66 rating with THD<20% & pf>0.9.The luminaire housing should be made of pressure die cast aluminimum.The total power consumption should not exceed25W (including driver) pre wired fitted on and including two Nos PVC block of suitablesize and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmmand testing complete including LED lamp complete all asspecified and as directed. Make : BAJAJENXT P 24L WH CR PC SD or itsequivalent inWipro, Bajaj, Philips, Shakti
26Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 70 Sqmm 3.5 corecomplete all as specified and directed Make:- M-Seal / Denson / Raychem
27All as per Item No 18 here in before but of size 95 Sqmm 3.5 core.
28All as per Item No 18 here in before but of size 35 Sqmm 3.5 core.
29All as per Item No 18 here in before but of size 25 Sqmm 4 core.
30M & L for painting of Steel tubular poles of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed.
31M & L for scrapping down rusted, fallen paint from the Electrical LT panel situatedincluding rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint on entire outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red oxide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB"sspecific cabinetcomplete all as specified and directed.
32M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of letter shall be 50 mm or less complete all as specified and directed.
33S&F in repairs Isolator TPN415 volts 63 Amp ACwith necessary connection in existingpanel/DB BOXcomplete all as specified and directed.
34S&F in repairsIsolator DP240 volts 40 Amp ACwith necessary connection in existingpanel/DB BOXcomplete all as specified and directed.
35S&F in repairs MCCBs four pole 415 volts.16 KA ,100Amp ACin existing panel board with modification /fabrication ofexisting panel board as directed by E-in-Chargecomplete all as specified and directed.
36S & F Thermo plastic cable looping boxes, factory made, IP 65 sheet of size 200 x 160 x 98mm seperate detached gland plate and including MCB TPN 20 Amps and bakelite connector 4 way 20 Amp with din rail, weather vermin proof, front door opening with hinge and locking arrangement fixed to polecomplete all as specified and directed. Make : Henselelectric/neptune or its equivalent in other makes.