Military Engineer Services-MES has published Repair Maintenance Of Led Security Street Lights And Other Connected Items In Txr And Domestic Area At Sonegaon- Phase - I & Phase Ii ( From Sl Item No. 1 To 12 ) Removing Old Pattern Single / Three Phase Electric Meteranddepositedto Age E / M Store Comp. Submission Date for this Tender is 14-05-2022. Bolts Tenders in Nagpur Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-May-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-05-2022 |
Sl. No. | Item Description |
1 | Taking down carefully old tube light/MH/HPSV Light fitting , 70/80/150/250/400 watt, unserviceable LED Street light fittings carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed.Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No. 2 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractor"s property as per Sch of Credit. |
2 | Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 1 here in before complete all as specified and directed. |
3 | (a) LED fittings 70 watt driver |
4 | (b) LED fittings 80 watt driver |
5 | (c) LED fittings 150 watt driver |
6 | (d) LED fittings 200 watt driver |
7 | Taking down carefully old security light/MH/HPSV Light fitting , unserviceableLED building security light fittings 25 watt carefully from towers and upto 10 meter poles, after disconnecting the supply, sealing the cable ends for carrying out repairs/maintenance at site/workshop complete all as specified and directed. |
8 | Supply only the spares LED fittings 20 watt driver required for replacement of spares during the process of repair of the light fitting vide SI item No 3 here in before complete all as specified and directed. |
9 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed. |
10 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
11 | Returning, filling inincluding spreading, levelling, watering and well ramming in layers not exceeding25 cm in soft/loose soil complete all as specified and directed. |
12 | M & L for providing dry river sand as in sand cushioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes |
13 | Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed. |
14 | M & L road cutting of size 30 cm width x 45 cm depth for laying of cables including making good the road with necessaryreturning filling and bituminious portion with concrete and bituminous mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching with the existing surfacescomplete all as specified and directed. |
15 | Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc forprotection of cables including taking down complete all as specified and directed |
16 | Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for the following sizes. |
17 | 50 sqmm, 3.5 core |
18 | 25 sqmm, 3.5 core |
19 | 16 sqmm, 4 core |
20 | 10 sqmm, 2 core |
21 | S&FLED street light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 70 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-BAJAJ Cat no. ENXT P 84L WH CR PC SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI |
22 | S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 200 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-,BAJAJ cat no. PRAZE F 240L WH NB-A5 TG SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI |
23 | S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-,BAJAJ cat no. PRAZE F 96L WH NB-A5 TG SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI |
24 | S&F LED Flood light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity ofcontrol gear box/driver and suitable flexible wiringwith 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron bracket or GI pipe in angle complete all as specified and directed. Make-,BAJAJ cat no. PRAZE F 180L WH NB-A5 TG SD or its equivalent make in PHILIPS, WIPRO, CG, SHAKTI |
25 | S & F 20 Watt LED Bldg security light with a nominal system.The luminaire shall have rated system lifetime of50,000 burning hours at L70.The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70.The luminaire shall meet IP66 rating with THD<20% & pf>0.9.The luminaire housing should be made of pressure die cast aluminimum.The total power consumption should not exceed25W (including driver) pre wired fitted on and including two Nos PVC block of suitablesize and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmmand testing complete including LED lamp complete all asspecified and as directed. Make : BAJAJENXT P 24L WH CR PC SD or itsequivalent inWipro, Bajaj, Philips, Shakti |
26 | Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 70 Sqmm 3.5 corecomplete all as specified and directed Make:- M-Seal / Denson / Raychem |
27 | All as per Item No 18 here in before but of size 95 Sqmm 3.5 core. |
28 | All as per Item No 18 here in before but of size 35 Sqmm 3.5 core. |
29 | All as per Item No 18 here in before but of size 25 Sqmm 4 core. |
30 | M & L for painting of Steel tubular poles of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed. |
31 | M & L for scrapping down rusted, fallen paint from the Electrical LT panel situatedincluding rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint on entire outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red oxide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB"sspecific cabinetcomplete all as specified and directed. |
32 | M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of letter shall be 50 mm or less complete all as specified and directed. |
33 | S&F in repairs Isolator TPN415 volts 63 Amp ACwith necessary connection in existingpanel/DB BOXcomplete all as specified and directed. |
34 | S&F in repairsIsolator DP240 volts 40 Amp ACwith necessary connection in existingpanel/DB BOXcomplete all as specified and directed. |
35 | S&F in repairs MCCBs four pole 415 volts.16 KA ,100Amp ACin existing panel board with modification /fabrication ofexisting panel board as directed by E-in-Chargecomplete all as specified and directed. |
36 | S & F Thermo plastic cable looping boxes, factory made, IP 65 sheet of size 200 x 160 x 98mm seperate detached gland plate and including MCB TPN 20 Amps and bakelite connector 4 way 20 Amp with din rail, weather vermin proof, front door opening with hinge and locking arrangement fixed to polecomplete all as specified and directed. Make : Henselelectric/neptune or its equivalent in other makes. |