| 1 | A. CONSTRUCTION OF 33KV LINE |
| 2 | 33KV Double Circuit Tower |
| 3 | i) D-type Tower (30°-60°) 2 Nos with auxilliary cross-arms (80kg per X-arm) |
| 4 | ii) 3M extension for D-type tower (2 nos) |
| 5 | Galvanized Bolts & Nuts with spring washers for 2 Nos. of Towers |
| 6 | Templates adjustable for |
| 7 | i) D-Type towers (30°-60°) |
| 8 | Tower Accessories |
| 9 | i) Pipe Earthing |
| 10 | ii) Danger Plate |
| 11 | iii) Number Plate |
| 12 | iv) Phase Plate (Set of Three) |
| 13 | v) Anti climbing device (with Barbed wire) |
| 14 | ACSR (Panther Conductor) (for 0.234Km) |
| 15 | Conductor Accessories |
| 16 | i) Compression Joint |
| 17 | ii) Repair Sleeve |
| 18 | iii) Vibration Damper |
| 19 | iv) P.G. Clamp |
| 20 | Earth/Ground wire (7/3.55cm) |
| 21 | Ground Wire Accessories |
| 22 | i) Compression Joint |
| 23 | ii) Tension Clamp |
| 24 | iii) Vibration Damper |
| 25 | iv) Repair Sleeve |
| 26 | v) Earth Bond |
| 27 | Disc Insulators 120KN |
| 28 | Hardware for Insulator String |
| 29 | i) Single Tension |
| 30 | ii) Double Tension |
| 31 | B. 33KV SUB STATION |
| 32 | Galvanized steel structure i/c bolts & nuts for (4 bays) |
| 33 | 5MVA, 33/11KV transformer with accessories |
| 34 | 33KV SF6 breaker |
| 35 | 33KV LA |
| 36 | 33KV PT |
| 37 | 33KV CT |
| 38 | 33KV Isolator (T/P) |
| 39 | i) with earth blade |
| 40 | ii) without earth blade |
| 41 | 33KV Contro & Relay panel for |
| 42 | i)Power Transformer |
| 43 | ii) feeder |
| 44 | 11 KVVCB Panels (with 2-incomer & 4-outgoing) |
| 45 | DC equipment |
| 46 | i) 24 V, 250AH Batterywith accessories (set of 12 cells) |
| 47 | ii) Battery charger (float-cum-boost) for 24Voltsbattery |
| 48 | iii) DC Distribution Board |
| 49 | LT AC Panel (6 feeder) |
| 50 | Switchyard lighting |
| 51 | i) 250W SON Lamps with fittings on Poles |
| 52 | ii)SON Lamps on switchyard structures |
| 53 | iii)500W Halogen Lamps on Switchyard Structures |
| 54 | Bus-Bar i/c Insulator Strings connector, Sheilding Wire, Post Insulator etc. |
| 55 | 40mm dia. 3Mtr long Pipe Electrodes. |
| 56 | 50x6 mm GI Flat for Earthing |
| 57 | Cables ( 11KV, 3C 150Sq.mm , UE. XLPE Cable for, 33/11KV Transformer , 1.1KV Copper Control Cables, 1.1KV PVC Cables, Cable Termination Kits, Straight Through joints, Power Connectors, Cable Glands etc ) |
| 58 | Fire fighting equipment |
| 59 | i) Dry Powder Type , 50lb for switchyard |
| 60 | ii) Form Type,1Gallon,Wall mounted for Battery Room |
| 61 | iii) Wall mounted, CO2, 10lb. capacity for control room |
| 62 | iv) 50lb, CO2 on Trolleys for Transformer |
| 63 | v) Sand Buckets (4 Nos/Stand)with Stand |
| 64 | Station Transformer 11/0.4KV 250KVA with reqd. materials |