}

Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, 11 / 132Kv Generator Transformers For Mukerian Hydel Project, Talwara, Punjab Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, , mukerian-Punjab

Punjab State Power Corporation Limited-PSTCL has published Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, 11 / 132Kv Generator Transformers For Mukerian Hydel Project, Talwara, Punjab Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, . Submission Date for this Tender is 10-08-2022. Container Tenders in mukerian Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

31881317
Corrigendum : Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, 11 / 132Kv Generator Transformers For Mukerian Hydel Project, Talwara, Punjab Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva,
Open Tender
Indian
Punjab
mukerian
10-08-2022

Tender Details

Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, 11 / 132Kv Generator Transformers For Mukerian Hydel Project, Talwara, Punjab Manufacturing, Testing, Supply And Erection And Commissioning Of 3 Nos. 25 Mva, 11 / 132Kv Generator Transformers For Mukerian Hydel Project, Talwara, Punjab , Part I : Supply , 25 Mva, 11 / 132Kv, Onan Cooled, Oil Immersed Outdoor Type Generator Transformer Suitable For 3-Phase, 50 C / S Frequency, Delta-Star Connected In Accordance With Iss Vector Group Yd 11 With Neutral Solidly Earthed On Hv Side. The Transformer Will Be Fitted With Off Ckt Tap Changer Of Easun-Mr / Telk / Bhel / Ngef / Cgl / Ctr / Paragon Associates / Alwaye Make Type 66 Kv, 300 Amps Rating For Voltage Variation On Hv Side To Give 142.5 Kv, 139 Kv, 135.5Kv, 132 Kv And 128.5 Kv With Lv Constant. Percentage Impedance On 25 Mva Base At 75 Deg.C Shall Be As 10% + Tolerance As Per Is-2026 Part-Ii Latest Edition. The Transformer Shall Be Able To Operate Continuously For 10% Overload Capacity. The Transformer Shall Be Dispatched Oil Filled. Transformer Oil ( Napthenic Base ) For Radiators& Conservators Etc. Alongwith 10% Extra Quantity Shall Be Dispatched Directly In Non-Returnable Epoxy Coated Steel Drums. The Transformer Shall Be Complete With All Fittings And Accessories As Per Specification. The Following Extra Spares With Each Transformer Shall Form Part Of Supplies , Hvline End Bushing Complete , Lv Line End Bushing Complete , Hv Neutral End Bushing Complete , Complete Sets Of Gaskets , Wti With Remote Indicator , Magnetic Oil Level Gauge , Oti With Remote Indicator , Silica Gel Container Along With Silicagel ( For One Time Filling ) For Main Tank , Pressure Relief Valve , Buchholz Relay , Dial Type Thermometer For Oti , Switches, Fuses, Relays For Electric Control Ckt. , Short Circuit Test Charges For 1 No. Gt ( If Applicable ) , Part Ii : Erection And Commissioning , Erection, Commissioning Of 25 Mva, 11 / 132Kv, Onan Cooled, Oil Immersed Outdoor Type Generator Transformer.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-May-2022 DATE EXTENSION TE 285/HPs/ED-III/M-141 Date 16-06-2022
2 16-Jun-2022 DATE EXTENSION- II TE 285/HPs/ED-III/M-141 Date 15-07-2022
3 19-Jul-2022 285/HPs/ED-III/M-141-corr3 Date 10-08-2022

Key Value

Document Fees
Refer document
EMD
INR 2000000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: MANUFACTURING, TESTING, SUPPLY AND ERECTION & COMMISSIONING OF 3 NOs. 25 MVA, 11/132KV GENERATOR TRANSFORMERS FOR MUKERIAN HYDEL PROJECT, TALWARA, PUNJAB.
Sl. No. Item Description
1Part I : Supply
225 MVA, 11/132KV, ONAN cooled, oil immersed outdoor type generator transformer suitable for 3-Phase, 50 C/S frequency, Delta-star connected in accordance with ISS Vector group YD 11 with neutral solidly earthed on HV side. The transformer will be fitted with off ckt tap changer of Easun-MR/ TELK/ BHEL/ NGEF/ CGL/ CTR/ Paragon Associates/ Alwaye make Type 66 KV, 300 Amps rating for voltage variation on HV side to give 142.5 KV, 139 KV, 135.5KV, 132 KV and 128.5 KV with LV constant. Percentage impedance on 25 MVA base at 75 deg.C shall be as 10% + tolerance as per IS-2026 Part-II latest edition. The transformer shall be able to operate continuously for 10% overload capacity. The transformer shall be dispatched oil filled. Transformer oil (Napthenic base) for radiators& conservators etc. alongwith 10% extra quantity shall be dispatched directly in non-returnable epoxy coated steel drums. The transformer shall be complete with all fittings and accessories as per specification. The following extra spares with each transformer shall form part of supplies
3HVline end bushing complete
4LV line end bushing complete
5HV neutral end bushing complete
6Complete sets of gaskets
7WTI with remote indicator
8Magnetic oil level gauge
9OTI with remote indicator
10Silica gel container along with Silicagel (for one time filling) for main tank
11Pressure Relief Valve
12Buchholz relay
13Dial type thermometer for OTI
14Switches, fuses, relays for electric control ckt.
15Short circuit test charges for 1 no. GT (If applicable)
16Part II : Erection and commissioning
17Erection, Commissioning of 25 MVA, 11/132KV, ONAN cooled, oil immersed outdoor type generator transformer.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail