Improvement Of Water Supply To Ranapur Nac ( Wtp ) Improvement Of Water Supply To Ranapur Nac ( Wtp )
Tender Value
3.88 Crore
Estimated cost
Bid Submission
10 May 2022
0 days left
EMD
3.88 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
ranapur → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Improvement Of Water Supply To Ranapur Nac ( Wtp ) Improvement Of Water Supply To Ranapur Nac ( Wtp )
BOQ
| Sl. No. | Item Description |
| 1 | Design, Drawing & Construction of 4.00 MLD Capacity Conventional Type Water Treatment Plant with Cascade aerator, Raw water channel, Chemical house, Chemical Store, Chlorine House with chlorination arrangementFlash Mixer/ Rapid Mix/ HBCF, Settling Tank, RGF/ Clariflocculator, Bye Pass channel, filter house with back wash arrangement with pump, CWR (0.40 ML), Clear water pump house, Lab, Administrative Block, internal road & lightining, internal drainage arrangement, internal electrification etc but excluding clear water pumps, External Electrification, Automation & instrumentation & sludge treatment. |
| 2 | Internal electrication to 2 nos pumps and control panel including cables etc. |
| 3 | Supply, Installation, Testing & Commissioning of light/Fan/Exhaust Fan point in 20mm dia medium gauge ISI markedGood quality PVC pipe with 1.5 sq.mm PVC insulated Cu.wire (2 run) &1.0 sq.mmPVC insulated Cu.wire (1 run) for running earth complete with 1 no .6Amp.1way plate type Modular switch (Polycarbonate) ,fan regulator, ply cover, angle holder/ceiling rose and G.I box of adequate size including PVC bend, saddle, elbow, etc and other necessary materials & labour complete as per the direction of Engineer-in-Charge. |
| 4 | Group-A (up to 2mtrs) |
| 5 | Group-B (up to 4mtrs) |
| 6 | Group-C(up to 6mtrs) |
| 7 | Secondary Point(Only wire from 1Lt Point to Another Lt Point-Upto 3mtr) . |
| 8 | Supply, Installation, Testing & Commissioning of 6/16A modular switch & socket outlet complete with 1 no of240 volt 6/16 amp 3 pin universal round/flat pin combined shuttered socket outlet &240 volt 16 amp control switch mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc.as required.complete as per the direction of Engineer-in-Charge. (MAKE- LEGRAND or equivalent brand and quality) |
| 9 | Supply and fixing ofComputer socket outlet complete with 3 no of 240 volt 6 amp 4 pin universal round/flat pin combined shuttered socket outlet & 2 no. of240 volt 6 amp control switch mounted on modular grid plate, all housed in a 8 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with +B17:B18all other accessories etc. as required complete as per the direction of Engineer-in-Charge..(MAKE- LEGRAND or equivalent brand and quality) |
| 10 | Circuit or Sub-main wiringin20/25/32/50mm dia. good quality ISI mark PVC Conduit withfollowing sizes PVC insulated un-sheathed 1100V,Single Core FRLS Cu. conductor wire of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ / HAVELLS or equivalent brand and quality) |
| 11 | (2 x 2.5 + 1 x 1.5) sq.mm copper wire. |
| 12 | Supply, Installation, Testing & Commissioning of 1 ph. 6 way,Single pole and Neutral, sheet steel MCB double horizontal door distribution box complete with tinned copper busbar, neutral link, earth bar, din rail, detachable gland plate includingcommissioning including all other materials etc. as required. -as per SLD.(MAKE- LIGRAND or equivalent brand and quality) |
| 13 | Supply, Installation, Testing & Commissioningof 6 amp to 32 amp rating 240 V \"C\" series miniature circuit breaker suitable for lighting and other loads in the MCB DB ISI marked complete with connections testing and commissioning etc. as required as per SLD.SINGLE POLE |
| 14 | Supply and fixing of 25 amp to 40amp,30mA DP rating 240 V \"C\" series RCCB suitable for inductive loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.as per SLD |
| 15 | Supply, Installation, Testing & CommissioningofTPN 415v 3 phase 200 amp switch disconnector fuseincluding all other materials etc. as required.as per SLD |
| 16 | Supply, Installation, Testing & CommissioningofTPN 415v 3 phase 300 amp 6 waybusbar cgamberincluding all other materials etc. as required .as per SLD |
| 17 | Supply, Installation, Testing & Commissioningof 20wtt 6k tub 220v ac lightincluding all other materials etc. as required.as per SLD |
| 18 | Supply, Installation, Testing & Commissioningof 9 inch metal body Exhaust Fan 220v ac lightincluding all other materials etc. as required.as per SLD |
| 19 | Supply, Installation, Testing & Commissioningof 90wtt street 220v ac light with bend pineincluding all other materials etc. as required.as per SLD |
| 20 | Design engineering procurement at materials and bought out components manufacturing assembly at shop inspection, testing and paints at manufacture\"s works packing, supply, unloading, transpotation, handing/stroage at site, assembly at site installation including touch up painting hook up, pre - commissioning and testing of the completing of the following capacity, DG set along with AMF panels , Acoustic , enclousure supply of all the special tools and tackies(as required) instrumentation all exhaust system & siencer, fuel tank, fuel piping, change over , cables including required silent DG sets of required capacity, Construction of base and shed etc. all complete as per the direction of the engineer in charge. |
| 21 | SilentD.G. sets(250 KVA) |
| 22 | Construction of Compound wall (800 mtr) |
| 23 | Earthwork in ordinary soil for foundationwithin initial leads & lifts including dressing and levelling of bed etc, complete. |
| 24 | P.C.C.(1:3:6) in foundation & plith using 40 mm size b.h.g.c.b metal including mixing of materials and laying in well prepared surface & compacting, watering curing with cost, conveyance, royalities of all materials, T&P and Labour charges etc. complete. |
| 25 | Filling in foundatin and plinth with sand watered and rammed including cost of sand & labour |
| 26 | R.C.C. M-20 Grade using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator and all leads and lifts including frame works etc. complete. In foundation & plinth |
| 27 | R.C.C. M-20 Grade using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator and all leads and lifts including frame works etc. complete. in superstructure |
| 28 | Columns |
| 29 | Plinth beam |
| 30 | Rigid & smooth centering & shuttering for R.C.C.works including false work & dismantling them after casting including cost of materials complete |
| 31 | R.C.C. foudation |
| 32 | Columns |
| 33 | Providing HYSD reinforcement for RCC works including bending, binding & placing in position as per Drawing including cost, conveyance of all materials, all labour and T&P etc complete. |
| 34 | Fly ash. bricks of 25cmx12cmx8cm. Size having crushing strength not less than 75 Kg/Sqcm. With dimensionaltolerance +2%. percentin cement mortar (1:6) in superstructure. |
| 35 | 12mm thick cement plaster in cm (1:6) out side with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 36 | Cement Washing two coats using cement including cost, conveyance of cement and cost of all labour etc. complete. |
| 37 | Supplying,Installation & Testing,Commissioning of 35 HP (68 LPS, 25 M Head) CentrifugalPumpset -2sets without control Panel etc complete. |
| 38 | Supplying all Labour, T&P, materials for Installation of Capacitor Bank as per direction of Engineer-in-Charge. (suitable for running of 35hp x 2 nos pumpsets). |
| 39 | Supplying & Installation of Star Delta Control Pannel with APFC arrangement. (suitable for running of 35hp x 2 nos pumpsets). |
| 40 | Installation of CI/MS Column pipe & Delivery pipe with sluice valve ,Non-Return valve, 300mm dia electro magnatic flow meter,Pressure gauge etc.for 2 sets . |
| 41 | Supplying all labour, T&P and Fixing the cast Iron sluice valve/Butter fly valve/scour valves with double flanged ends for water works purpose for the following rating and nominal diameters (including cost of bolts,nuts and rubber insertion sheet & cost of the cast iron sluice valves) as per specification, complete as per the direction of the Engineer -in-charge(including 1% labour cess) 200mm dia D.I.D/F Sluice valve (PN-1.60) without wheel |
| 42 | Supplying all materials, labour, T&P and fixing swing check type Reflux Valves (Non-return valves) with double flanged ends conforming to IS : 5312 (Part-I) - 2004 for water works purposes for the following rating and nominal diameters as per specification complete and direction of Engineer-in-charge. (including cost of bolts, nuts and rubber insertion sheet & cost of the cast iron Reflux Valves (Non-return valves) |
| 43 | 200mm dia |
| 44 | Fixing Double Air Relief Valve conforming to IS 14845 : 2000 for water works purposes for the following diameters including drilling the water main (Cast iron pipes with metal straps) as per specificationcomplete |
| 45 | 80mm diameter |
| 46 | Fixing Pressure Release Valve with componentsconforming to IS:14150-2005 as per specificationcomplete |
| 47 | 80 mm diameter Pressure Release Valve |
| 48 | Supplying & Laying in trenches MS pipes of all Classes conforming to IS:3589 - 2001 & IS:3601 - 2006 of the following outside diameter as per specification complete. (Earthwork in trenches, jointing of pipes,specials and fittings to be measured separately)including cost of pipe,conveyance of all materials to worksite,contractor profit & labour cess etc all complete as per direction of Engineer-in-charge. |
| 49 | 219.10mm O.D.M.S. pipe 6.30mm thick) |
| 50 | Supplying all materials, labour, T&P for flame cutting and facing of MS plate or pipes upto 12mm to 25mm thick including cost of all labor, material,conveyance to worksite,contractor profit & labour cess for following plate thickness all complete as per specification and direction of Engineer-in-Charge. |
| 51 | Providing joints by welding with two welding beads/pass, conforming to IS:816-1998 (Single 60° Butt weld) to MS pipes and fittings at site by using welding generator including testing of joints, as per specification complete and direction of Engineer-in-charge. |
| 52 | Providingflanged joints conforming to IS:3114-1994 to flanged Cast Iron pipes and fittings of the following nominal diameters including testing of joints, cost of bolts and nuts and rubber insertions but excluding cost of MS flange as per specification complete and direction of Engineer-in-charge. |
| 53 | 200 mm dia pipe |
| 54 | Supplying and Fixing of Water Meters (Electro Magnegnetic flow meter) with double flanged ends for the following nominal diameter as per specificationcomplete. |
| 55 | 200 mm dia |
| 56 | Design, Drawings, Construction of Store Cum Watchman Shed ofsize 3.0 x 5.0m (including toilet) plinth area with Provision of electrical installation and sanitary installation to the watchman as per direction of Engineer-in-Charge. |
| 57 | Earthwork in ordinary soil for foundationwithin initial leads & lifts including dressing and levelling of bed etc, complete. |
| 58 | P.C.C.(1:3:6) in foundation & plith using 40 mm size b.h.g.c.b metal including mixing of materials and laying in well prepared surface & compacting, watering curing with cost, conveyance, royalities of all materials, T&P and Labour charges etc. complete. |
| 59 | Filling in foundation and plinth with sand watered and rammed including cost of sand & labour. |
| 60 | R.C.C. M-20 Grade using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator and all leads and lifts including frame works etc. complete. In foundation & plinth. |
| 61 | R.C.C. M-20 Grade using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator and all leads and lifts including frame works etc. complete. in superstructure. |
| 62 | Columns |
| 63 | Plinth beam |
| 64 | Lintels |
| 65 | Roof Beam |
| 66 | Slab |
| 67 | Rigid & smooth centering & shuttering for R.C.C.works including false work & dismantling them after casting including cost of materials complete. |
| 68 | R.C.C. foudation |
| 69 | Colums,pillars etc. |
| 70 | Beams, lintels etc. |
| 71 | Roof, Slab and Chajja |
| 72 | Providing HYSD reinforcement for RCC works including bending, binding & placing in position as per Drawing including cost, conveyance of all materials, all labour and T&P etc complete. |
| 73 | Fly ash. bricks of 25cmx12cmx8cm. Size having crushing strength not less than 75 Kg/Sqcm. With dimensionaltolerance +2%. percentin cement mortar (1:6) in superstructure. |
| 74 | 12mm thick cement plaster in cm (1:6) out side with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete |
| 75 | 16mm thick cement plaster in cm (1:6) with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 76 | 6mm thick c.p. in cm (1:4) Over RCC surface with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 77 | Fixing Vertified floor tiles of premium grade having thickness 8 mm to 10 mm confirming to IS:13756 of following sizes infloors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete excluding cost of Tile. |
| 78 | Antiskid Floor Tile -in Toilet(Make -Johnson / Khajaria/Somali) |
| 79 | Fixing Tiles to dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles all complete with & without cost of precast tiles.(room & toilet) |
| 80 | Wall painting two coats with weather coat ofapproved shade on new work to give an even shade including cost of paint all labour T&P etc complete. |
| 81 | Finishing wall surfaces of walls with Acrylic wall putty of approved make and finished smooth and even surfaces to receive painting including cost of scaffolding staging charges with cost of all materials, taxes, labour T & P etc completed. |
| 82 | Supplying & Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc including cost of all materials etc complete. |
| 83 | Cement Washing two coats using cement including cost, conveyance of cement and cost of all labour etc. complete. |
| 84 | Finishing exterior wall with cement paint of approved shade on new work of two coats including cost of paints and primer and labour charges etc complete. |
| 85 | 2.5 cm grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips etc complete |
| 86 | Dressed seasoned sal wood work framed and fixed in frames of doors & windows including cost, conveyance of all materials and labour charges etc complete. |
| 87 | 32mm Teak wood panelled shutters (of 32mm style with 18mm panel) including cost conveyance of all materials and labour for fitting excluding cost of iron fittings etc complete. |
| 88 | Painting two coats with enamel paints over one coat of primer with approved quality paints & primer to Wood/Iron work including cost of paints & primer, T&P and labour charges etc complete. |
| 89 | ELECTRICAL PORTIONS: Supply, Installation, Testing & Commissioning oflight/Fan/Exhaust Fan point in 20mm dia medium gauge ISI markedGood quality PVC pipe with 1.5 sq.mm PVC insulated Cu.wire (2 run) &1.0 sq.mmPVC insulated Cu.wire (1 run) for running earth complete with 1 no .6Amp.1way plate type Modular switch (Polycarbonate) , 1 no fan regulator and G.I box of adequate size including PVC bend, saddle, elbow, etc and other necessary materials & labour complete as per the direction of Engineer-in-Charge. |
| 90 | Group-A (up to 2mtrs) |
| 91 | Group-B (up to 4mtrs) |
| 92 | Group-C(up to 6mtrs) |
| 93 | Secondary Point(Only wire from 1Lt Point to Another Lt Point-Upto 3mtr) . |
| 94 | Supply, Installation, Testing & Commissioning of 6A modular switch & socket outlet complete with 1 no of 240 volt 6 amp 5 pin universal round/flat pin combined shuttered socket outlet & 1 no. of240 volt 6 amp control switch mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc. as required complete as per the direction of Engineer-in-Charge. (MAKE- LEGRANDor equivalent brand and quality). |
| 95 | Supply, Installation, Testing & Commissioning of 6/16A modular switch & socket outlet complete with 1 no of240 volt 6/16 amp 3 pin universal round/flat pin combined shuttered socket outlet &240 volt 16 amp control switch mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc.as required.complete as per the direction of Engineer-in-Charge. (MAKE- LEGRANDor equivalent brand and quality). |
| 96 | Supply, Installation, Testing & Commissioning of 20/25A one way switch all housed in a single 1 module recessed zinc chromate passivated MS box includingmoulded cover plate with all other accessories etc. as required complete as per the direction of Engineer-in-Charge.(MAKE- LEGRANDor equivalent brand and quality ) |
| 97 | Supply, Installation, Testing & Commissioning of 20/25A modularsocket outlet complete with 1 no of240 volt 20 amp 4 pin universal round/flat pin combined shuttered socket outletfor S.AC indoor and Out Door unit mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc.as required.complete as per the direction of Engineer-in-Charge.(MAKE- LEGRANDor equivalent brand and quality). |
| 98 | Supply, Installation, Testing & Commissioning ofCalling Bell point in20mm dia. good quality ISI mark PVC Conduit with 1.5 sq.mm PVC insulated Cu.wire (2 run) &1.0 sq.mmPVC insulated Cu.wire (1 run) for running earthcomplete with 1 no .6Amp. bell push with indicator, 1 module white metal plate & G.I box of adequate size including PVC bend, saddle, elbow, etc and all other necessary materials & labour.as per the direction of Engineer-in-Charge. |
| 99 | Supply &fixing ofTelephone point suitable forRJ 11 telephone socket including mounting box (G.I/PVC) & top cover of approved make to be fixed in concealed manner in partition/wall by necessary bolts & nuts with all other accessories etc. as required complete as per the direction of Engineer-in-Charge. (MAKE- LEGRANDor equivalent brand and quality) |
| 100 | Supply and fixing ofTV antennaSocket outlet completelyproviding 1 no. of TV antenna socket & Top , moulded case metal box & plate of adequate size includingPVC bend, saddle, elbow, etc. & other necessary materials &labour complete as per the direction of Engineer-in-Charge. complete as per the direction of Engineer-in-Charge.(MAKE- LEGRANDor equivalent brand and quality) |
| 101 | Supply and fixing ofComputer socket outlet complete with 3 no of 240 volt 6 amp 4 pin universal round/flat pin combined shuttered socket outlet & 2 no. of240 volt 6 amp control switch mounted on modular grid plate, all housed in a 8 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with +B17:B18all other accessories etc. as required complete as per the direction of Engineer-in-Charge..(MAKE- LEGRAND). |
| 102 | Circuit or Sub-main wiringin20/25/32/50mm dia. good quality ISI mark PVC Conduit withfollowing sizes PVC insulated un-sheathed 1100V,Single Core FRLS Cu. conductor wire of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ / HAVELLS) |
| 103 | (2 x 1.5 + 1 x 1.0) sq.mm copper wire. |
| 104 | (2 x 2.5 + 1 x 1.5) sq.mm copper wire. |
| 105 | (2 x 4 + 1 x 1.5) sq.mm copper wire forAC Point. & Geyser Point. |
| 106 | Supply, Installation, Testing & Commissioning of 2 pairs telephone wires ( 0.5 Sqmm) in 20/25 mm dia. good quality ISI mark PVC Conduit withfollowing sizes PVC insulated un-sheathed 1100V,Single Core FRLS Cu. conductor wire of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ DLIK/ HAVELLS) |
| 107 | Supply, Installation, Testing & Commissioningof RJ-6 TV wire in20/25 mm dia. good quality ISI mark PVC Conduit withfollowing sizes of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ DLIK/ HAVELLS) |
| 108 | Supply, Installation, Testing & Commissioning of 1 ph. 8 way,Single pole and Neutral, sheet steel MCB double horizontal door distribution box complete with tinned copper busbar, neutral link, earth bar, din rail, detachable gland plate including commissioning including all other materials etc. as required. -as per SLD. (MAKE- LIGRANDor equivalent brand and quality) |
| 109 | Supply, Installation, Testing & Commissioningof 6 amp to 32 amp rating 240 V \"C\" series miniature circuit breaker suitable for lighting and other loads in the MCB DB ISI marked complete with connections testing and commissioning etc. as required as per SLD.SINGLE POLE |
| 110 | Supply and fixing of 25 amp to 40amp,30mA DP rating 240 V \"C\" series RCCB suitable for inductive loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.as per SLD |
| 111 | Supply, Installation, Testing & Commissioningof 20wtt 6k tub 220v ac lightincluding all other materials etc. as required.as per SLD |
| 112 | Supply, Installation, Testing & Commissioningof 18wtt 9 inchExhaust Fan 220v ac lightincluding all other materials etc. as required.as per SLD |
| 113 | Supply, Installation, Testing & Commissioningof 100wtt street 220v ac light with bend pineincluding all other materials etc. as required.as per SLD |
| 114 | WATER SUPPLY PORTIONS : Fixing of Brass Screw-down Bib Cocks (Taps) polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete. |
| 115 | 15mm dia CP Brass Short Body Bib Cock |
| 116 | 15mm dia CP Brass long body Bib Cock |
| 117 | 15mm dia CP extension piece - 25mm long |
| 118 | 15mm dia CP flange |
| 119 | Fixing Chromium Plated Brass Shower rose with 15mm or 20mm inlet including polishing all complete as per specification. |
| 120 | Fixing of Brass Screw-down Stop Cocks conforming to IS:781-1995 of the following nominal sizes as per specification complete. |
| 121 | 15mm dia CP Brass Angle Stop Cock |
| 122 | 15mm dia CP Brass Concealed Stop Cock |
| 123 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 124 | Stainless steel kitchen sink - without drain board 600x450 mm bowl depth 200 mm (Parry Ware). |
| 125 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge. |
| 126 | 1000 litre capacity Double Layer Cylinderical Vertical water storage tanks(ISI Marked). |
| 127 | RCC beam Staging for installationof PVC tanks with Fly ash Brick Masonary in CM (1:6) |
| 128 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. |
| 129 | 25 mm nominal outer dia pipes |
| 130 | 20 mm nominal outer dia pipes |
| 131 | Fixing of Brass or Gun Metal Full Way Valve conforming to IS:781-1995 of the following nominal sizes with wheel as per specification complete. |
| 132 | 25mm dia Brass or Gun Metal Full Way Valve |
| 133 | 32mm diameter |
| 134 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (SDR-11)conforming to IS 15778, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer- in-Charge. |
| 135 | 32 mm nominal outer dia pipes |
| 136 | Fixing of Brass Ball Valve (Horizontal plunger type) conforming to IS 1703-1977 as per specification complete. |
| 137 | 32mm dia nominal bore with Copper or PVC Ball Valve (Horizontal plunger type) |
| 138 | Fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of the following nominal bore as per specification. |
| 139 | 15mm diameter |
| 140 | 15mm dia CP pillar cock long neck |
| 141 | Cutting holes through existing brick work including makinggood the same in cement mortar (1:4) for takingGI/PVC pipes and fittings etc all complete as per specification. |
| 142 | 250mmthick wall |
| 143 | Cutting hole in R.C.C floors and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof. |
| 144 | Cutting grooves in pucca floors and walls for takingGI/PVC pipes and making good the damages as per specification complete. |
| 145 | Fixing ferrule conforming to IS:2692-1978 of the following nominal bore including drilling thewater main (Cast Iron pipesorpipes with the metal straps) as per Specification complete. |
| 146 | 10mm to 25mm bore |
| 147 | Supplying all labour T & P, material for construction ofStop Cock Chamber as per direction of engineer in charge. |
| 148 | SANITARY INSTALLATION : Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. |
| 149 | Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3-2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification. |
| 150 | 580 mm x 440mm size white glazed Vitreous China Orissa Pattern squatting pan. |
| 151 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 152 | 10 litre capacity - White |
| 153 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 154 | Stainless steel kitchen sink - without drain board 600x450 mm bowl depth 200 mm. |
| 155 | Fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. |
| 156 | Chromium Plated brass towel rail (20mm X 600mm long) |
| 157 | Fixing standard sized Chromium Plated brass towel ring fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. |
| 158 | Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification. |
| 159 | Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification. |
| 160 | Fixing Cast (Spun) Iron floor traps of the following nominal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification. |
| 161 | Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. (Seat and cover to be measured and paid for separately). |
| 162 | Fixing(b) Chromium Plated brass soap dish complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws. . |
| 163 | Supplying all labour, tools and plants ,materials for fixing of CP Gratings. |
| 164 | Sewage Disposal System |
| 165 | Supplying all labour, T&P, Materials for Construction of Gully Trap Chamber with fly ash brick masonary and Rcc cover.(250x250x675)mm. as per specification and direction of engineer in charge. |
| 166 | Supplying all labour, T&P, Materials for Construction of Inspection Chamber. (0.90x0.80x0.45) m with fly ash brick masonary and S.F.R.C Cover. as per specification and direction of engineer in charge. |
| 167 | Supplying all labour, T&P, Materials for Construction of Man Hole Chamber-(0.9mx0.9x0.90m). as per specification and direction of engineer in charge. |
| 168 | Septic Tank (10 Users) - 1no |
| 169 | Supplying all labour, T&P and earth work in excavation in all kinds of soil within initial lead of 50m lead & initial lift of 1.50m. including rough dressing breaking clods & laying in layers not exceeding 0.30m. In depth, leveling the bed, using pans, vessels for slushy soil & including sundries supervision charges & labour cess etc, as per the direction of Engineer-in-charge. |
| 170 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to work site, payment of royalty , taxes ,contractor profit &labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 171 | Supplying all materials, labour, T&P and providing cement concrete(1:4:8) with 40cm size crusher broken black hard granite metal including watering , curing, conveyance of all materials to work site, payment of royalty taxes& labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 172 | Supplying all labour, materials ,T&P and providing Cement concrete (1:2:4) with crusher broken hard granite chips on 12mm size RCC works including cost of conveyance & royalty ,sundries , watering ,curing &lifting &laying concreteat a height of 5mtr. Maximumcomplete etc all complete(Excluding cost of reinforcement & centering & shuttering) |
| 173 | R.C.C work in ground floor of M-20 gradewith 20mm & down grade crusher broken hard Granite chipsincluding hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 174 | Supplying all materials, labour, T&P and providingrigid andSmooth centering and shuttering for R.C.C. works including False work and dismantling them after casting including Conveyance of all materials to Work site, payment of royalty taxes & labour cessetc all complete as per specification and direction of Engineer-in-charge. |
| 175 | Brick work with Fly ash bricks of 25cmx12cmx8cm. Size having crushing strength not less than 75 Kg/Sqcm. With dimensionaltolerance +2%. percentt in cement mortar (1:4) in foundation and plinth. |
| 176 | 12mm thick cement plaster in cm (1:6) out side with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 177 | 12mm thick cement plaster (1:4) over brick work with cement punning for skirting. |
| 178 | Cost of Steel reinfocement and providing in RCC works. |
| 179 | Soak way pit (1.20 m dia x 1.5 m deep) with RCC ring. as per specification & direction of engineer in charge. |
| 180 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 181 | 110mm diameter U-PVC SWR pipes (4kgf) |
| 182 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion. |
| 183 | 110mm pvc coupler |
| 184 | Single tee with door 110x110x110 mm pvc |
| 185 | 110mm pvc dia plain bend |
| 186 | 110mm pvc cowl |
| 187 | 110 pvc offset |
| 188 | Providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the following type of surrounding or encasing salt-glazed stoneware pipes/pvc pipes of the following internal diameter including concrete for bedding and curing complete as per PH specification. TYPE- C 1STANDARD BEDDING : |
| 189 | 100mm diameter |
| 190 | Design, Drawings & Construction of Staff Quarter for Pump Operators (04 nos) as per direction of Engineer-in-Charge.(As per Annexure-5). |
| 191 | Earthwork in ordinary soil for foundationwithin initial leads & lifts including dressing and levelling of bed etc, complete. |
| 192 | P.C.C.(1:3:6) in foundation & plith using 40 mm size b.h.g.c.b metal including mixing of materials and laying in well prepared surface & compacting, watering curing with cost, conveyance, royalities of all materials, T&P and Labour charges etc. complete. |
| 193 | Filling in foundatin and plinth with sand watered and rammed including cost of sand & labour. |
| 194 | R.C.C. M-20 Grade using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator and all leads and lifts including frame works etc. complete. In foundation & plinth. |
| 195 | R.C.C. M-20 Grade using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator and all leads and lifts including frame works etc. complete. in superstructure. |
| 196 | Columns |
| 197 | Plinth beam |
| 198 | Lintels |
| 199 | Roof Beam |
| 200 | Roof Slab |
| 201 | Rigid & smooth centering & shuttering for R.C.C.works including false work & dismantling them after casting including cost of materials complete. |
| 202 | R.C.C. foudation |
| 203 | Colums,pillars etc. |
| 204 | Beams, lintels etc. |
| 205 | Roof, Slab and Chajja |
| 206 | Providing HYSD reinforcement for RCC works including bending, binding & placing in position as per Drawing including cost, conveyance of all materials, all labour and T&P etc complete. |
| 207 | Fly ash. bricks of 25cmx12cmx8cm. Size having crushing strength not less than 75 Kg/Sqcm. With dimensionaltolerance +2%. percentin cement mortar (1:6) in superstructure. |
| 208 | 12mm thick cement plaster in cm (1:6) out side with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 209 | 16mm thick cement plaster in cm (1:6) with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 210 | 6mm thick c.p. in cm (1:4) Over RCC surface with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 211 | Fixing marbles12mm. thick C.P (1:1) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete excluding cost of marble. |
| 212 | Fixing marbles to dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete excluding cost of marble. |
| 213 | Wall painting two coats with weather coat ofapproved shade on new work to give an even shade including cost of paint all labour T&P etc complete. |
| 214 | Finishing wall surfaces of walls with Acrylic wall putty of approved make and finished smooth and even surfaces to receive painting including cost of scaffolding staging charges with cost of all materials, taxes, labour T & P etc completed. |
| 215 | Supplying & fixing of M.S. Grills, M.S.Doors, M.S. Gate etc including cost of all materials etc complete |
| 216 | Cement Washing two coats using cement including cost, conveyance of cement and cost of all labour etc. complete. |
| 217 | Wall painting 2 coats with of approved shade on new work to give an even shade in (Using Asin paintweather Coat Apex Ultima )Ground Floor. |
| 218 | 2.5 cm grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips etc complete. |
| 219 | Dressed seasoned sal wood work framed and fixed in frames of doors & windows including cost, conveyance of all materials and labour charges etc complete. |
| 220 | Painting two coats with enamel paints over one coat of primer with approved quality paints & primer to Wood/Iron work including cost of paints & primer, T&P and labour charges etc complete. |
| 221 | ELECTRICAL PORTIONS : Supply, Installation, Testing & Commissioning oflight/Fan/Exhaust Fan point in 20mm dia medium gauge ISI markedGood quality PVC pipe with 1.5 sq.mm PVC insulated Cu.wire (2 run) &1.0 sq.mmPVC insulated Cu.wire (1 run) for running earth complete with 1 no .6Amp.1way plate type Modular switch (Polycarbonate) , 1 no fan regulator and G.I box of adequate size including PVC bend, saddle, elbow, etc and other necessary materials & labour complete as per the direction of Engineer-in-Charge. |
| 222 | Group-A (up to 2mtrs) |
| 223 | Group-B (up to 4mtrs) |
| 224 | Group-C(up to 6mtrs) |
| 225 | Secondary Point(Only wire from 1Lt Point to Another Lt Point-Upto 3mtr) . |
| 226 | Supply, Installation, Testing & Commissioning of 6A modular switch & socket outlet complete with 1 no of 240 volt 6 amp 5 pin universal round/flat pin combined shuttered socket outlet & 1 no. of240 volt 6 amp control switch mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc. as required complete as per the direction of Engineer-in-Charge. (MAKE- LEGRANDor equivalent brand and quality). |
| 227 | Supply, Installation, Testing & Commissioning of 6/16A modular switch & socket outlet complete with 1 no of240 volt 6/16 amp 3 pin universal round/flat pin combined shuttered socket outlet &240 volt 16 amp control switch mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc.as required.complete as per the direction of Engineer-in-Charge. (MAKE- LEGRANDor equivalent brand and quality). |
| 228 | Supply, Installation, Testing & Commissioning of 20/25A one way switch all housed in a single 1 module recessed zinc chromate passivated MS box includingmoulded cover plate with all other accessories etc. as required complete as per the direction of Engineer-in-Charge.(MAKE- LEGRAND) |
| 229 | Supply, Installation, Testing & Commissioning of 20/25A modularsocket outlet complete with 1 no of240 volt 20 amp 4 pin universal round/flat pin combined shuttered socket outletfor S.AC indoor and Out Door unit mounted on modular grid plate, all housed in a 3 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with all other accessories etc.as required.complete as per the direction of Engineer-in-Charge.(MAKE- LEGRAND or equivalent brand and quality). |
| 230 | Supply, Installation, Testing & Commissioning ofCalling Bell point in20mm dia. good quality ISI mark PVC Conduit with 1.5 sq.mm PVC insulated Cu.wire (2 run) &1.0 sq.mmPVC insulated Cu.wire (1 run) for running earthcomplete with 1 no .6Amp. bell push with indicator, 1 module white metal plate & G.I box of adequate size including PVC bend, saddle, elbow, etc and all other necessary materials & labour.as per the direction of Engineer-in-Charge. |
| 231 | Supply &fixing ofTelephone point suitable forRJ 11 telephone socket including mounting box (G.I/PVC) & top cover of approved make to be fixed in concealed manner in partition/wall by necessary bolts & nuts with all other accessories etc. as required complete as per the direction of Engineer-in-Charge. (MAKE- LEGRANDor equivalent brand and quality) |
| 232 | Supply and fixing ofTV antennaSocket outlet completelyproviding 1 no. of TV antenna socket & Top , moulded case metal box & plate of adequate size includingPVC bend, saddle, elbow, etc. & other necessary materials &labour complete as per the direction of Engineer-in-Charge. complete as per the direction of Engineer-in-Charge.(MAKE- LEGRANDor equivalent brand and quality |
| 233 | Supply and fixing ofComputer socket outlet complete with 3 no of 240 volt 6 amp 4 pin universal round/flat pin combined shuttered socket outlet & 2 no. of240 volt 6 amp control switch mounted on modular grid plate, all housed in a 8 module recessed zinc chromate passivated flush metalbox including mosaic white cover plate of approved make with +B17:B18all other accessories etc. as required complete as per the direction of Engineer-in-Charge..(MAKE- LEGRAND or equivalent brand and quality ) |
| 234 | Circuit or Sub-main wiringin20/25/32/50mm dia. good quality ISI mark PVC Conduit withfollowing sizes PVC insulated un-sheathed 1100V,Single Core FRLS Cu. conductor wire of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ / HAVELLS). |
| 235 | (2 x 1.5 + 1 x 1.0) sq.mm copper wire. |
| 236 | (2 x 2.5 + 1 x 1.5) sq.mm copper wire. |
| 237 | (2 x 4 + 1 x 1.5) sq.mm copper wire forAC Point. & Geyser Point. |
| 238 | Supply, Installation, Testing & Commissioning of 2 pairs telephone wires ( 0.5 Sqmm) in 20/25 mm dia. good quality ISI mark PVC Conduit withfollowing sizes PVC insulated un-sheathed 1100V,Single Core FRLS Cu. conductor wire of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ DLIK/ HAVELLS). |
| 239 | Supply, Installation, Testing & Commissioningof RJ-6 TV wire in20/25 mm dia. good quality ISI mark PVC Conduit withfollowing sizes of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (MAKE- FINOLEX/ DLIK/ HAVELLS). |
| 240 | Supply, Installation, Testing & Commissioning of 1 ph. 12 way,Single pole and Neutral, sheet steel MCB double horizontal door distribution box complete with tinned copper busbar, neutral link, earth bar, din rail, detachable gland plate includingcommissioning including all other materials etc. as required. -as per SLD.(MAKE- LIGRAND or equivalent brand and quality) |
| 241 | Supply, Installation, Testing & Commissioningof 6 amp to 32 amp rating 240 V \"C\" series miniature circuit breaker suitable for lighting and other loads in the MCB DB ISI marked complete with connections testing and commissioning etc. as required as per SLD.SINGLE POLE |
| 242 | Supply and fixing of 25 amp to 63amp,30mA DP rating 240 V \"C\" series RCCB suitable for inductive loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.as per SLD. |
| 243 | Supply, Installation, Testing & Commissioningof 20wtt 6k tub 220v ac lightincluding all other materials etc. as required.as per SLD. |
| 244 | Supply, Installation, Testing & Commissioningof 9 inchExhaust Fan 220v ac lightincluding all other materials etc. as required.as per SLD. |
| 245 | Supply, Installation, Testing & Commissioningof 100wtt street 220v ac light with bend pineincluding all other materials etc. as required.as per SLD. |
| 246 | Water Supply : Fixing of Brass Screw-down Bib Cocks (Taps) polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete. |
| 247 | 15mm dia CP Brass Short Body Bib Cock |
| 248 | 15mm dia CP Brass long body Bib Cock |
| 249 | 15mm dia CP extension piece - 25mm long |
| 250 | 15mm dia CP flange |
| 251 | Fixing Chromium Plated Brass Shower rose with 15mm or 20mm inlet including polishing all complete as per specification. |
| 252 | Fixing of Brass Screw-down Stop Cocks conforming to IS:781-1995 of the following nominal sizes as per specification complete. |
| 253 | 15mm dia CP Brass Angle Stop Cock |
| 254 | 15mm dia CP Brass Concealed Stop Cock |
| 255 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 256 | Stainless steel kitchen sink - without drain board 600x450 mm bowl depth 200 mm (Parry Ware). |
| 257 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge |
| 258 | 1000 litre capacity Double Layer Cylinderical Vertical water storage tanks(ISI Marked) |
| 259 | RCC beam Staging for installationof PVC tanks with Fly ash Brick Masonary in CM (1:6) |
| 260 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. |
| 261 | 25 mm nominal outer dia pipes |
| 262 | 20 mm nominal outer dia pipes |
| 263 | Fixing of Brass or Gun Metal Full Way Valve conforming to IS:781-1995 of the following nominal sizes with wheel as per specification complete. |
| 264 | 25mm dia Brass or Gun Metal Full Way Valve |
| 265 | 32mm diameter |
| 266 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (SDR-11)conforming to IS 15778, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer- in-Charge. a) 32 mm nominal outer dia pipes |
| 267 | Fixing of Brass Ball Valve (Horizontal plunger type) conforming to IS 1703-1977 as per specification complete.a) 32mm dia nominal bore with Copper or PVC Ball Valve (Horizontal plunger type) |
| 268 | Fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of the following nominal bore as per specification. |
| 269 | 15mm diameter |
| 270 | 15mm dia CP pillar cock long neck |
| 271 | Cutting holes through existing brick work including makinggood the same in cement mortar (1:4) for takingGI/PVC pipes and fittings etc all complete as per specification. a)250mmthick wall |
| 272 | Cutting hole in R.C.C floors and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof. |
| 273 | Cutting grooves in pucca floors and walls for takingGI/PVC pipes and making good the damages as per specification complete. |
| 274 | Fixing ferrule conforming to IS:2692-1978 of the following nominal bore including drilling thewater main (Cast Iron pipesorpipes with the metal straps) as per Specification complete. |
| 275 | 10mm to 25mm bore |
| 276 | Supplying all labour, T&P materials for construction of Stop Cock Chamber as per specification & direction of engineer in charge. |
| 277 | SANITARY INSTALLATION: Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. |
| 278 | Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3-2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification. |
| 279 | 580 mm x 440mm size white glazed Vitreous China Orissa Pattern squatting pan. |
| 280 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. a)10 litre capacity - White |
| 281 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 282 | Stainless steel kitchen sink - without drain board 600x450 mm bowl depth 200 mm. |
| 283 | Fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. |
| 284 | Chromium Plated brass towel rail (20mm X 600mm long) |
| 285 | Fixing standard sized Chromium Plated brass towel ring fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. |
| 286 | Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification. |
| 287 | Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification. |
| 288 | Fixing Cast (Spun) Iron floor traps of the following nominal diameter of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification. |
| 289 | Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. (Seat and cover to be measured and paid for separately). |
| 290 | Fixing(b) Chromium Plated brass soap dish complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws. |
| 291 | Supplying all labour, tools and plants , matterials for fixing of CP Gratings. |
| 292 | SEWERAGE DISPOSAL SYSTEM |
| 293 | Supplying all labour, T&P, Materials for Construction of Gully Trap Chamber with fly ash brick masonary and Rcc cover.(250x250x675)mm. as per specification and direction of engineer in charge. |
| 294 | Supplying all labour, T&P, Materials for Construction of Inspection Chamber.(0.90x0.80x0.45)m with fly ash brick masonary and S.F.R.C Cover. as per specification and direction of engineer in charge. |
| 295 | Supplying all labour, T&P, Materials for Construction of Man Hole Chamber-(0.9mx0.9x0.90m). as per specification and direction of engineer in charge. |
| 296 | SEPTIC TANK (10 USERS) -4 nos |
| 297 | Supplying all labour, T&P and earth work in excavation in all kinds of soil within initial lead of 50m lead & initial lift of 1.50m. including rough dressing breaking clods & laying in layers not exceeding 0.30m. In depth, leveling the bed, using pans, vessels for slushy soil & including sundries supervision charges & labour cess etc, as per the direction of Engineer-in-charge. |
| 298 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to work site, payment of royalty , taxes ,contractor profit &labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 299 | Supplying all materials, labour, T&P and providing cement concrete(1:4:8) with 40cm size crusher broken black hard granite metal including watering , curing, conveyance of all materials to work site, payment of royalty taxes& labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 300 | Supplying all labour, materials ,T&P and providing Cement concrete (1:2:4) with crusher broken hard granite chips on 12mm size RCC works including cost of conveyance & royalty ,sundries , watering ,curing &lifting &laying concreteat a height of 5mtr. Maximumcomplete etc all complete(Excluding cost of reinforcement & centering & shuttering) |
| 301 | R.C.C work in ground floor of M-20 gradewith 20mm & down grade crusher broken hard Granite chipsincluding hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 302 | Supplying all materials, labour, T&P and providingrigid andSmooth centering and shuttering for R.C.C. works including False work and dismantling them after casting including Conveyance of all materials to Work site, payment of royalty taxes & labour cessetc all complete as per specification and direction of Engineer-in-charge. |
| 303 | Brick work with Fly ash bricks of 25cmx12cmx8cm. Size having crushing strength not less than 75 Kg/Sqcm. With dimensionaltolerance +2%. percentt in cement mortar (1:4) in foundation and plinth. |
| 304 | 12mm thick cement plaster in cm (1:6) out side with watering, curing and cost, conveyance royality of all materials & cost of all labour charges etc. complete. |
| 305 | 12mm thick cement plaster (1:4) over brick work with cement punning for skirting. |
| 306 | Cost ofsupply of Steel reinfocement and providing in RCC works. |
| 307 | Soak way pit (1.20 m dia x 1.5 m deep) with RCC ring. as per specification & direction of engineer in charge. |
| 308 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 309 | 110mm diameter U-PVC SWR pipes (4kgf) |
| 310 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion. |
| 311 | 110mm pvc coupler |
| 312 | Single tee with door 110x110x110 mm pvc |
| 313 | 110mm pvc dia plain bend |
| 314 | 110mm pvc cowl |
| 315 | 110 pvc offset |
| 316 | Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of surrounding or encasing salt-glazed stoneware pipes/pvc pipes of the following internal diameter including concrete for bedding and curing complete as per PH specification. TYPE- C 1STANDARD BEDDING : |
| 317 | 100mm diameter |
| 318 | Approach road (500 mtr) |
| 319 | Supplying all materials, labour, T&P and filling of road surface with borrow earth from the approved quarry and compacting to the requireddensity with testing including cost of royalty\"lead & transportation & labour cess etc all complete as per the direction of Engineer-in-charge. |
| 320 | Supplying moorum for sub base of road at work site from the approved quarry including cost of all materials, taxes, royalty, conveyance & labour cess etc all complete. |
| 321 | Supplying all labour, T&P and Laying of sub base of road in layers not exceeding 100mm. Wattering and compacting to the required dencity with testingincluding cost of roayality,lead & transportation etc all complete. |
| 322 | Supplying 4cm size hard granite metal forroad work at work site including cost of all labour, T& P etc all complete. I.R.C. Grade I I (63mm to 45mm) |
| 323 | Supplying all labour, T&P and Spreading metals and packing the voids with small stone & hand packing to proper camber including conveying & spreading of filler materials and filling the interstics by spreading the same over the surface, watering and consolidation with P.R.R. |
| 324 | Supplying all materials, labour, T&P and providing rough stone dry packing in approns and revetment with hard granite stone including cost of all materials, taxes,conveyance of all materials to work site, labour cess etc all completeas per specification and direction of Engineer-in-charge. |
| 325 | Site devlopment |
| 326 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area . |
| 327 | Fine dressing of earth work in ordinary or hard soil in road formaton according to the direction of the department including cutting or filling earth upto 0.15m depth of surface |
| 328 | Road lighting |
| 329 | Supply, Installation, Testing & Commissioning of l Hot dip galvanizedlighting Pole 6m hight with Powder coating , the work include supplying and installing the following :- 2 decorative arms.- 2 lanterm IP 65, with LED lamps 27W .-3*2.5mmsq cable inside 1 Inch flexible conduit for Luminaries.-Control box with 1x10 A DP MCB-Steel base with B250 concrete foundations 60x60x60cm.- All needed Bolts ,Nuts ,Washers, Terminal connections, Accessories, & all needed reinforced cement .All works must be According to drawing and supervisor Instructions. |
| 330 | Supplying all Labour, T&P, materials Fixing of Water Meters (Electro Magnegnetic flow meter) with double flanged ends for the following nominal diameter as per specificationcomplete. i) 300mm dia |
AI Tender Summary
Tender Timeline
Apr 19, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMay 10, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 11, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender