}

81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla. 81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla., khadakwasla-Maharashtra

Military Engineer Services-MES has published 81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla. 81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla.. Submission Date for this Tender is 07-05-2022. Air Conditioner Tenders in khadakwasla Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

31839436
Corrigendum : 81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla. 81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla.
Open Tender
Indian
Maharashtra
khadakwasla
07-05-2022

Tender Details

81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla. 81713Provn Of Air Conditioning Of Air Traffic Control Tower At Aftt Nda Khadakwasla.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Apr-2022 Corrigendum No 1 dated 26 April 22 Date 07-05-2022
2 28-Apr-2022 Corrigendum No 02 dated 28 April 2022 BOQ 07-05-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 76720.0 /-
Tender Value
INR 38.36 Lakhs /-

BOQ Items

Name of Work :PROVN OF AIR CONDITIONING OF AIR TRAFFIC CONTROL TOWER AT AFTT NDA KHADAKWASLA.
Sl. No. Item Description
1Supply & Installation of Modular Extendible type 100 % All Inverter Variable Refrigerant Flow Outdoor units comprising of Hermetically sealed INVERTER Variable Speed Scroll compressors. The unit shall comprise of high efficiency, low noise condenser fan with guard and IP 55 motor, heat exchanger and coated fins for increased durability. The casing shall be powder coated and the unit shall be provided with liquid line strainer, catch all drier, thermostats etc.suitable for interconnecting with any type of indoor units with cordless / corded remote controller. The ODU & IDU shall be integrated with special super wiring system with the central monitoring control. The unit shall be factory wired and tested before despatch. The operating refrigerant shall be R-410A only.The unit shall be IBMS compatible with open protocol. Outdoor should give 100% Capacity at 43% Deg C Ambient Tempratur. The COP of the Outdoor units should be more than 3.5 at design conditions.The rate includes AC DB P&S TP/SP20amp metal plug and socket distribution board of 8 Nos as specified and as directed.The VRF Unit should be capable in suchway that refrigerant piping limits shall be as under between Indoor Units & Outdoor units shall be extendable upto 180M of equivalent length. Maximum height difference between outdoor Unit & indoor Unit of 90 M (ODU above IDU), Level difference between Indoor Unit Maximum upto 40 M(a) The condensing unit shall have two compressors for 14 HP & above capacity. (b) The unit shall work for the following ambient condition Range Cooling Mode: 10 Deg C to 56 Deg C, Heating mode : -10 Deg C to 24 Deg C, 20 HP OUT DOOR UNIT(Consists of 2 x 10 HP Units)
2Supply of VRFbased Large Cassette & Compact Cassette machine complete with Fan section with Fan/Cooling Coil suitable for HFC-410a With electronic expansion valve, return air filter, insulated drain tray,inbuit drain pump and necessary controls, 2.5 HP-8 Nos
3Supply of Centralized Controller, Remote Controllers & Refnet Joints as design by OEM, Cordless Remote-08 Nos, Refnet Joints (Indoor Unit) -07 Nos, Refnet Joints (Outdoor Unit)
4LOW SIDE WORK: REFRIGERANT PIPING (a) Supply installation, testing and commissioning ofhard/soft copper refrigerant piping, insulated with 13mm thick and 19mm thick for suction line closed cell nitrile rubber insulation, complete with fittings, elbows, bends supporting arrangement on walls Make : Armacell/Aeroflex (b) Copper piping of size from outdoor unit to indoor unit upto 130 mtr (c) Supply installation, termination , testing and commissioning control wiring of required size for outdoor unit and indoor unit - 130 mtr (d) Supply, installation,testing and commissioning of Additional top up- referigerant, outdoor unloading & shifiting on roof and Pressure Testing and commisioning -01 Job (e) S&F CPVC drain piping for the units insulated with 6mm nitrile rubber (as per site condition) 32 mm dia - 80 mtr
5MS stand for outdoor units zinc chromate primer duly epoxy coated - 02 Nos.
6Supply, installation, testing and comissioning ofinsulation of under deck with 25 mm thick open cell nitrile rubber with anti microbial treatment & of class "I stuck inside the using rubber adhessives (F M approved), density of 140-180 kg/m cub - 30 Sqm.
7Outdoor Unloading & shifting on Roof.
8Pressure Testing and commisioning Note: Line diagram of copper pipe and selection of refnet should be recommended by OEM and approved before procurement. Make : Blue star / LG / Samsung / Daikin / Carrier
9Supply , installation testing and commissioning automatic operation, three phase Servo Controlled naturally oil cooled indoor type Voltage stabilizer & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 V with accuracy ± 1% and of capacity 30 KVA completed all as specified and directed including the followings:- (a) Low Voltage Cut off in case in put voltage goes below the range. (b) High Voltage Cut off in case in put voltage goes above the range . (c) Low/High frequency protection. (d) Single phasing prevention. (e) Phase reversal prevention. (f) Earth fault protection. (g) Delay on Circuits. (h) Overload/ Short circuit Protection. (j) Alarm enunciator for auditable indication of above faults. (k) Ampere Meter with CTs and Selector Switch. (l) Input Spikes and surge protection type I & II. (m) Stabilizer by pass system. (n)Insulation Class - A (o)Temperature rise - 50?C in oil. (p)Efficiency -98.5-99% at full load at unity power factor. (q)Control. -Auto / Manual (r) Indications - LED for each Phase to indicate mains ON, Output ON, Under voltage, Over voltage, Overload, Single Phasing & Trip. (s) Winding - Copper. (t) Response Time -Less than 8V / Sec per Phase. (u) Trip - Incorporated by means of contactor to trip in eventof under voltage, Over voltage, Overload, Single Phasing alongwith audio alarm. (v) Metering - Digital Microprocessor Based Cards for voltage, Output load current with CT. (w)Protections - Overload, Short Circuit, High/Low Voltage cut off & Bypass arrangement to be provided. (x) Oil -First filling of oil to be provided. (y) Fittings - Four Plain Rollers, Two Earthing Terminals, Four Lifting Hooks, Oil filling hole with cap, drain wall, oil level indicator, (z)Testing -All routine tests as per DGAQA & IS to be conducted & Test reports to be furnished along with equipment. Note :- (i) Contractor should submit the drawing for approval of Engineer In Charge before procurement. (ii) Testing of voltage stablizer shall be carried out by electrical inspector depoted by appropriate authority. Make : Vintec / V guard / Aplab / Sinetrac / Automatic Electric
10M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) connected to galvanized iron strip 25 x 4 mm, 7.5 mtr long by means of bolts, nuts and washers of galvanized iron or steel, GI light grade protection pipe 15mm dia, GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No 3 of SSR-2009 pt-I and testing complete including earth work excavation in any type of earth strata PCC 1:2:4 as in earthing pit, 50 mm PCC pit cover with 6mm iron handle attached , common salt charcoal all as specified including testing on complete. Note GI strip beyond 7.5 mtr shall be measured and paid for seprately.
11M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 25 x 4mm GI strip complete all as specified and as directed.
12M&L for brickwork with subclass "B" Bricks straight or curved on plan exc 6m means radius buit in CM 1:6 complete all as specified and as directed.
13M&L for Cement concrete 1:3:6 type C2 using 40mm stone aggregate foundation/resting platform in foundation filling and mass concrete complete all as specified and as directed.
14M&L for mild steel rolled section connected with each other with welding (angle, tee, channel, beam, hollow sections etc) as in main and cross beams, hip verticle hollow sections and jack rafters, purlins where connected to common rafters and running rils where verticle suctions and fixed in welded in wallsin wall surface with plates and other verticle sections are fixed in ground level embedded in concrete fixed and horizontal sections fixed in wall with bolt completly, fixed with angle, cleats or other connecting plates conforming to Gde Fe -410-W (Gde E-250) quality-B complete all as specified and directed by Engr-in-charge
15M&L for Pre painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall tixed with self tapping screws complete all as specified and as directed.
16Supply & laying in trenchs or refixing on wall with shaddle and testing cableXLPE insulted screened, PVC bedded galvanizer steel strip or wire armoured electric powercables (heavy duty) 1100 Volts grade with standard aluminium conductor of size25 sqmm 4 core complete all as specified and as directed.
17All as per item No 09here- in- abovebut of size 16 sqmm 4 core complete all as specified and as directed.
18S&F sheet metal MCB DB 8 way (double door) VTPN with 200 Amps rated copper bus bar suitable for 100 amp MCCB Incomer and the rate includes of8 Nos of MCB TP 240 Volts 20Amp breaking capacity10KAOutgoing complete all as specified and as directed.
19S&F and connecting MCCB 4 pole 415 Volts 100 amps having breaking capacity 16KAcomplete all as specified and as directed.
20M&L for wiring for circuit / Submain wiring along with earth wire with with the following sizes of FRLS PVC insulated copper conductor single corecable in surface/recessed as required in PVC casing caping of size 2 x 2.5 sqmm + 1 x 1.5 sqmm earth wire complete all as specified and as directed.
21Supply and Laying including testing and commissioning LT UG Power cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade multi-stranded aluminium conductor including galvanised or Cadmium plated high tensile nuts, bolts and washers etc including termination on both side of LT Feeder pillar/Panel/Bus Bar Panel complete all as specified and directed of size 3.5 Core 95 Sqmm.
22Excavation in trenches, n.exc 1.5 m wide and n. exc 1.5 m depth and getting out in for foundation of pole, stay, laying of cable and pipe etc :
23Hard/dense soil
24Soft / disintegrated rocks
25Returning and filling in, including spreading and well ramming in layers n exc 25 cm complete all asdirected.
26Removing excavated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all directed.
27M&L for dry sand for cushioing to under ground cable in trenches incl spreading, leveling and hand punning complete all specified. Note : For measurement purpose punned thickness shall be considered.
28Supply and Laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mm x 150mmx 40mm for protection of cable from mechanical damage complete all as specified and as directed.
29S&F Busbar Box weather proof outdoor type single door, fabricated out of3.15 mm thick CRCAsheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finishwith seven tank pre treatment process.The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-43, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof.All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable.The panel shall be provided with aluminium bus bars of 200 Amps current rating, electrolytic grade including required size of nut bolts for fixing of cables.The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 35 mm x 35 mm x 4 mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement.The overall size of the Busbar panel shall notbe less than 500 mm x 300 mm x 700 mm (LxWxH) including earthwork all as directed and specified by Engr in Chrage.
30Supply, installation, testing and commissioning LT Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7032 (Siemens Gray) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-43, front side double door type with locking arrangementfor front side and back side also, comprising ofgaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel.The panel shall be provided with aluminium bus bars, electrolytic grade of 400 Amp current rating.The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured.All joints and cable connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc.The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming.The panel shall be provided with manufacturer"s name plate, skull & bones danger notice board etc.The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement .All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for all incoming and outgoing MCCBs complete all as specified and as directed. The overall size of the panel shall not less than 1000 mm X400 mm X 1000 mm (L x D x H).The panel shall be provided for Cable entry from bottom side for 4 No of Cable, size upto 185 sqmm with suitable size of SS Cable Glands including2 Nos of Earting Terminals one on each side of the Panel including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge.
31ON LOAD change over switch four pole with advance Neutral 200 Amps current rating manual changeover front side handle operated conforming to IS 13947 (Part-3) including RYB LED Indication Lamp for both incoming cables.
32S&F MCCB, 4 Pole 200 Amp, 25 KA Conforms to IS/IEC 60947-3, Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separater etc. (Incoming) - 01 No
33S&F MCCB 4 Pole, 415 Volts, 100 Amp with Thermal Magnetic release, 16 KA, Conforms to IS/IEC 60947-2,Ics = 100% Icu suitable for Isolation, Adjustable Overload setting : 0.8-1.0 x In with both side of spreader links and phase separator etc. (Outgoing) - 02 No.
34S&F of Cable Route Marker made up of Cast Iron of dia 100 mm and thickness 4.65 mm with supporting angle iron of size 20 x 20 x 3 mm and height 0.6 mtr for stand including priming, painting and wirting of "LT CABLE" in suitable size of letter including necessary earthwork and grouted at suitable depth in PCC 1:3:6 Type C2 using 40 mm graded aggregate in mass concrete complete all as specified and directed at site by Engr-in-Charge.
35M&L for Road Cutting as required for laying pipe/cable etc including earthwork and necessary excavation including making good with required material to match with the existing one complete all as specified and as directed by Engineer-in-charge.
36M&L for tubes, Light Grade, galvanised with all fittings, laid in trenches for protection of Cable for Road/Path Way Crossing etc of 100 mm dia size complete all as specified and directed by Engr-in-Charge.
37M&L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to Change over switch panel including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover including with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
38M&L for GI Earthing Strip size 25 x 4 mm thick buried directly in ground or fixed on wall with suitable size of SMC / FRP insulators including bolts, nuts and washers etc beyond the 7.5 mtr length complete all as specified and directed by Engr-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail