| 1 | Excavating over areas, n exc 1.5 m deep and getting out in hard /dense soil, complete all as specified and directed. |
| 2 | All as per item No. 1.00 above but exc 1.50m and n exc 3.00 m deep complete all as specified and directed. |
| 3 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre deep for laying water main pipe/ cablesetc.,getting out and forming bottom surface to required gradient, complete all as specified and as directed. |
| 4 | Returning, filling in, of soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed. |
| 5 | Removing excavated materials not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed. |
| 6 | M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregated as in foundation, complete all as specified and directed. |
| 7 | M & L for 25 mm thick PCC 1:2:4, type B-O, using 12.5mm graded stone aggregate finished fair and even etc complete all as specified and directed. |
| 8 | M & L for Non-skid ceramic colour tiles 7 to 8 mm thick, (square /rectangular), area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and directed. |
| 9 | M & L for Glazed ceramic colour tiles of size 300 x 450 x7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed. |
| 10 | M & L for vitrified / Durastone / Endura parking tiles size 300mm x 300mm x 12mm thickas in floorsset and jointed in neat cement slurry and pointed inwhite cement to match the surface complete all as specified and directed. |
| 11 | M & L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement Mortar 1:6., complete all as specified and directed. |
| 12 | M & L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in CM 1:4 complete all as specified and directed. |
| 13 | M & L for precast cement concrete 1:2:4, type B0 using 12.5mm graded aggregates as in louvres and jallies, 25mm thick (measured solid) set in cement mortar 1:4, including all moulding etc complete all as specified and directed. |
| 14 | Taking down plaster on brick or concrete surfaces including raking out joints for key and scrubbing down with water etc complete all as specified and directed. |
| 15 | M & L for 15mm thick renderingin cement mortar 1:4 on fair faces of brick work or concrete surfacesusing integral water proofing compound 3% by weight of cement and finishing the surface even and smooth without using extra cement complete all as directed and directed. Note:- WPC shall be measured and paid separately. |
| 16 | Supply only integral water proofing compound complete all as specified & directed. |
| 17 | Rendering 10mm thick onother than fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement), complete all as specified and directed. |
| 18 | M & L for applying a coat of 1.5 mm thick Birla wall care putty as per manufacture instruction complete all as specified and directed. |
| 19 | M & L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and directed. |
| 20 | M & L for complete removal of existing treatment by scrapping, wire brushing from old walls and applying two coats of oil bound distemper including preparation of surfaces complete all as specified and directed. |
| 21 | M & L for preparation of new plastered surfaces of wall including cornices, pilasters etc and applying three coat of white wash complete all as specified and directed. |
| 22 | M & L for preparation of new plastered surface and applying two coats of cement base paint on surfaces of wall complete all as specified and directed by EIC. |
| 23 | M & L for preparation of new decorated plastered surfaces of wall including cornices, pilasters etc and applying two coat of white wash complete all as specified and directed. |
| 24 | M & L for 10mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 25 | M & L for 6mm to 8mm,TMT bar cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 26 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces., complete all as specified and directed. |
| 27 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surfaces, complete all as specified and directed. |
| 28 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs etc also splays between floors and beams etc complete all as specified and as directed. |
| 29 | M & L for RCC 1:2:4 type B-1,(using 20mm graded crushed stone aggregate) as in slab supported on walls, Beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed. |
| 30 | M & L for RCC M-30 in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 31 | M & L for RCC M-30 in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses, complete all as specified and directed. |
| 32 | S & F factory solid PVC door frame of size 50mm x 47 mm made out of 5mm wood grain printed PVC sheet reinforced with MS Square tube as per specified & drawing in opening complete all as specified and directed. |
| 33 | S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face complete all as specified and directed. |
| 34 | S & F MS butt hinges of 100 mm size cold rolled mild steel medium weight, ISI marked complete all as specified and directed. |
| 35 | S & F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 36 | S & F 125 mm size Extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 37 | S & F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 38 | Excavation in post holes (or similar holes) each n.exc. 0.50 cum, getting out, in soft/loose including returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering and removingsurplus soil to a distance n.exc 50 m and makinggood surface complete all as specified and directed. |
| 39 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 40 | M & L forrolled mild steel square/rectangular hollow section in main and cross beam, purlins hips and jack rafters where connected to common rafters running railsfixed with angle cleats or other connecting plated, grade Fe 410W (Gde -E-250) Quality A., complete all as specified and directed. |
| 41 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 42 | M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 43 | S & F 15 mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 44 | S & F for grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and directed. |
| 45 | S & F PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls for 75mm borecomplete all as specified and directed. |
| 46 | S & F 75mm dia PVC (SWR) bends any radius, complete all as specified and directed. |
| 47 | M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified anddirected. |
| 48 | M & L for 75mm thick cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate finished even & smooth without using extra cement as in plinth protection including forming joint to full depth at every 3.0m interval and at every charge of direction and filled mixture of bitumen and sand (1:3) by weight, complete all as specified and directed. |
| 49 | S & F for 15mm bore bib tap, chromium plated fancy type, screwed down, high pressure for iron pipe or for brass ferrule, complete all as specified and directed. |
| 50 | INTERNAL ELECTRIFICATION:- M&L for point wiring with 1.5 Sqmm (nominal area) single core PVC insulated 1100 Volts, grade multi stranded (FR-LSH) copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type cast iron or pressed steel terminal box for mounting of modular switches, sockets, fan regulator etc with modular white cover plate with frame for suitable module as per site requirements and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth including cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings of following, complete all as specified and directed:- (Note:- Cost of cutting chase and making good shall be included in the quoted rate.)Make:- Havells/Finolex/Polycab (a) One light point controlled by one way, one switch SP 230 Volts |
| 51 | (b) One 3/5 pin 5 Amp socket outlet point controlled by one way, one switch on same board. |
| 52 | (c) One 3/5 pin 5 Amp socket outlet point controlled by one way one switch on independent board. |
| 53 | (d) One 5 pin, 15 amps socket controlled by Independent 15 Amps switch but with cable 2.5 sqmm. |
| 54 | S & F modular switch 1 way 16 Amp, 1 module, complete all as specified and directed. |
| 55 | S & F modular socket 6 Amp/16 Amp, 2/3 pin combined, 2 module complete all as specified and directed. |
| 56 | S & F modular switch 6 Amp/10 Amp, 2/3 pin combined, 1 module complete all as specified and directed. |
| 57 | S & F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and directed |
| 58 | S & F ceiling rose, 3phase/PVC/Polycarbonate, isolated body, 3 pin surface, white /any shade, three terminals. complete all as specified and directed. |
| 59 | S & F MCB distribution board steel sheet enclosures, powder coated fitted with bus bar, neutral link, earth bar din rail conforms IS-8822:96 and EIC 898-96,240 volts double door when MCB SPN 8 way, 200 amps rated bus bar to be used, complete all as specified and directed. |
| 60 | S & F MCB in DB\"s/ Isolator of the following rating complete all as specified and directed.(a) MCB SPN40 Amps, curve \"C\" breaking capacity 10 kA. |
| 61 | (b) MCB SP 6- 32 Amps, curve \"C\" breaking capacity 10 kA. |
| 62 | S & F LED tube light fitting (separate box fitting and LED rod) acrylic linear tube (1x 18 watt), 230V for single LED light fitting & rod (1 x 18W LED) bar professional CW 6500 K cover channel in box fitting,bipin holders, LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make:- Bajaj /Havells/ Philips |
| 63 | M & L for earthling complete with GI earth plate electrode 60 cm x 60 cm x 6.30 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work,PCC pit with RCC cover, charcoal salt funnel, GI wire up to 7.5 mtrs length complete all as specified and directed. |
| 64 | EXTERNAL WATER SUPPLY & ELECTRIC SUPPLY:- Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size6 Sqmm 2 core. complete all as specified and directed. |
| 65 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size10 Sqmm 2 core. complete all as specified and directed. |
| 66 | S & F single pole and neutral sheet metal enclosure with two pin earth plug and socket complete with one MCB 10 Amp, 240A double pole complete all as specified and directed. |
| 67 | S & F Rigid non-metallic PVC conduit of 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc complete all as specified and directed. |
| 68 | Supply, installation, testing and commissioning direct online starter, 3 phase, AC, 415V for 15 HP centrifugal pump set complete all as specified and directed by Engr-in-Charge. |
| 69 | M & L for PCC type C2 1:3:6 (using 40mm graded aggregate) for foundation of size60cmx60cmx30cm, including plaster work and angle iron arrangement covered from top with galvanium sheet suitable for fitting of sheet metal enclosure complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supplying, laying, jointing and testing (including diversion/change of route) for galvanised steel tubing 25mm bore, ISI marked, \"Medium grade\" with all fitting such as bends, elbows, tees, short pieces, union, etc., and laid in trenches/surfaces/walls complete all as specified and as directed.Make:-Tata/Jindal/Prakash Surya |
| 71 | Supplying, laying, jointing and testing (including diversion/change of route) for galvanised steel tubing 20mm bore, ISI marked, \"Medium grade\" with all fitting such as bends, elbows, tees, short pieces, union, etc., and laid in trenches/surfaces/walls complete all as specified and as directed.Make:-Tata/Jindal/Prakash Surya |
| 72 | S & F PPR Gate Valves (Brass Insert) of 25 mm bore complete all as specified and as directed. |
| 73 | S & F PPR Gate Valves (Brass Insert) of 20 mm bore complete all as specified and as directed. |
| 74 | M & L for cutting in position / existing main pipe line of any size with GI pipe line 25 mm dia & insertion of new GI Tee of suitable sizefor making pipe connection complete all as specified and directed. |
| 75 | M & L for cutting in position / existing main pipe line of any size with GI pipe line 20 mm dia & insertion of new GI Tee of suitable sizefor making pipe connection complete all as specified and directed. |
| 76 | S & F rotational moulded polyethylene triple layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 25mm/20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
| 77 | S & F water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed. |
| 78 | S & F Bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed . |