Construction Of District Ware House With Integrated Blood Bank At Sadar Hospital Campus Chatra.
Tender Value
3.38 Crore
Estimated cost
Bid Submission
20 Apr 2022
0 days left
EMD
3.40 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
chatra → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of District Ware House With Integrated Blood Bank At Sadar Hospital Campus Chatra.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Apr-2022 | TIME COMPLETION PERIOD | Other | 20-Apr-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B). |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches withina lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including\" cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 5 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 6 | Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. |
| 7 | Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinthwith approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 8 | Providing designation 75B brick work in CM (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials. raking out joints yo 15 mm depth, curing, taxes androyalty all complete as per building specification and direction of E/I. |
| 9 | Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I. |
| 10 | Providing designation 100A brickwork with fly ash lime brick (FLAG) confirming to IS:12894-1990 (9\" x 4.5\" x 3\") in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 11 | Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\" x 4.5\" x 3\") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stoneaggregate 20 mm nominal size) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6(1Cement:3coarsesand(zone-III):6gradedstoneaggregate40mm nominal size) |
| 14 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level.1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 16 | Reinforced cement concrete work in wall (any thickness), including attached pilasters, butterses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts ets. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work inbeams, suspended floor, roofs having slope up to 15\"\" landing, balconies, shelver, chajjas , lintels, bands, plan window sills, staircases and spiral stair case above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 18 | Providing Toe steel reinforcement of 8mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STEEL) |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns etc. for mass concrete. |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc. |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth bams, griders, bressumers and contilevers. |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for :Stairs,(excluding landings) except spiral-staircasess. |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade,Chajjas, corbels etc. including edges |
| 25 | Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick. |
| 26 | Providing and laying damp-proof course 50mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stoneaggregate 12.5mm nominal size) |
| 27 | Providing TOR steel reinforcement of 8mm, 10mm , 12mm , 16mm dia rods or bars as per approved design and drawingexcluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Ltd, Bokaro and Vizal Steel) |
| 28 | Providing TOR steel reinforcement of 20mm, 25mm , 28mm , 32mm dia rods or bars as per approved design and drawingexcluding carriage of bars to work site, cutting, bending, and binding with annealed wire with cost of wire, removal of rust, placing th rods in position all complete as per building specification and direction of E/I. (Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Ltd, Bokaro and Vizal Steel) |
| 29 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge. |
| 30 | Providing and fixing factory made panel PVC door shutter consisting offrame made out of M.S. tubes of 19 gauge thickness and size of 19 mmx 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frameshall have a coat of steel primers of approved make and manufacture.M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel ofsize 30 mm thickness, 70 mm width out of which 50 mm shall be flat and20 mm shall be tapered in 45 degree angle on both side forming stylesand 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flatand 20 mm shall be tapered in 45 degree on the inner side to form topand bottom rail and 115 mm wide PVC sheet out of which 75 mm shall beflat and 20 mm shall be tapered on both sides to form lock rail. Top,bottom and lock rails shall be provided both side of the panel. 10 mm (5mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insertfor top rail & bottom rail, paneling of 5 mm thick both side PVC sheet tobe fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm(5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, andjoined together with solvent cement adhesive. An additional 5 mm thickPVC strip of 20 mm width is to be stuck on the interior side of the \"C\"Channel using PVC solvent adhesive etc. complete as per direction ofEngineer-in-charge, manufacturer\"s specification & drawing. 30 mm thick plain PVC door shutters |
| 31 | Supplying, fitting and fixing 35mm thick solid core type non decorative single leaf flush shutters in doors and windows with block board core blendedwith high quality pehnol formal dehyde synthetic resin both side commercial veneered of standard makewith oxidised ironfittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 32 | Supplying, fitting and fixing 35mm thick solid core type non decorative double leaf flush shutters in doors and windows with block board core blendedwith high quality pehnol formal dehyde synthetic resin both side commercial veneered of standard makewith oxidised ironfittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 33 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 34 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separatelyPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 35 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as perthe architecturaldrawings and the directions of engineer-in-charge With float glass panes of 4.0 mm thickness (weight notless than 10 kg/ sqm) |
| 36 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as perthe architecturaldrawings and the directions of engineer-in-charge With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 37 | Providingandfixingaluminiumextrudedsectionbodytubulartype universalhydraulicdoorcloser(havingbrandlogowithIS:3564, embossed on the body door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 38 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete125 mm |
| 39 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete Twin rubber stopper |
| 40 | Supplying, fitting, and fixing250 x 20 x 6mm L-type M.S. clamp properly fishtailed, including making holes and setting the same in 375x125x75mm. Cement concrete block (\"1 .2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I |
| 41 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold ofmildsteelangleofsection50x25mm,orbasetiesof1.60mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B , Fixing with adjustable lugs with split end tail to each jamb |
| 42 | Supplying, fitting, and fixing M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing , properly fabricated with joints continuous fillet welded and finished, carriage of grill to work site, hoisting as per building speficiation and direction of E/I. (where material is not supplied by the deppt.) |
| 43 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where material is not supplied by the deppt.) |
| 44 | Supplying,fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20X\"10X2 mm. at 100mm. Centres and braced with M.S. flat diagonals 20 X 3mm, with top and bottom rails of T. iron 40x40x6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification arrd direction E/|. |
| 45 | Supplying, fitting and fixing 20 guage GCI sheet gate fitted on M.S> angle frame of size 60X60X6mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in PCC (1:2;4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 46 | Providing and fixing stainless steel (grade 304) railing made of Hollow tubes, channels, plates etc,. Including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessry stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasterners etc,.) |
| 47 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 48 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 49 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red,Elite Brown, Cat Eye or equivalent. |
| 50 | Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent |
| 51 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade(Area of slab over 0.50 sqm) |
| 52 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 53 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 54 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqmincluding pointing the joints with white cement and matching pigment etc., complete. |
| 55 | Providing and laying Doublecharge vitrifed floor tiles in differents size (thickness to be i specrfred by lhe maiirifacturer) with water absorption less than 0.08% and conformrng to lS 15622 / SO 13006 of approved make, in all cotours and I shacjes laid on 20mrn tlrick\"cement mortar 1 4 (1 cement:4 coarse Isancl) lointing witir grey cement slurry @ 3.3 kg/ sqm including I grouting tiie joints v/ith v/hite cement and matching pigments etc., I cornplete Size of l-ile 600x600 mm |
| 56 | Providing and laying 25mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime mortar (1:1:1) (1 lime putty sucrkhi coarse sand) laid over and jointed with grey cement slurry mixed with pigement to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. - 600 X 600mm size |
| 57 | Providing and laying 15 to 23mm thick Kotah stone tiles in risers of steps, skirting and pillars of approved size, taxture and colour and over 12mm thick cement mortar (1:3) and joined with grey cement slury mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing, txes and royalty all complete as per building specifiction and direction of E/I. |
| 58 | Chequered precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)- light shade using white cement |
| 59 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge. |
| 60 | Providing 12mm Thick cement plaster (1:6) with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I |
| 61 | Providing 6mm Thick cement plaster (1:4) in ceiling with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I |
| 62 | Providing 12mm thick cement plaster (1:3)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 63 | Providing 12mm thick waterproof cement plaster (1:4) with clean coarse sand F.M.1.5 with 5% cico or any other approved water proofing compound including curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I |
| 64 | Making 6x6mm grooves in plaster surface over walls truely horizontal or vertical as specified. at regular intervals, at all heights including cleaning, finishing, scaffoding and curing wth all leads and lifts of water all complete as per building specification and direction of E/| |
| 65 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building speicification and direction of E/I. |
| 66 | Providing & laying water proofing treatmentin sunken portion of WCs, bathrooms etc. by applying cement slurry mixed with Armourcrete of M/S The Structural Water Proofing Company PVT. Ltd.or Tapecrete of M/s CICO Engg. Servce consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @0.125 kg/ sq.m. This layer will be allowed to air cure for 4 hours (b)second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @0.126 kg/ sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preperation of surface, treatment& sealing of all joints, corners, junctions of pipes & masonary with polymer mixed slurry. |
| 67 | Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :- (a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with \"150mm X \"150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damagedconcretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, llexrble cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SqmUcoat For the fJUrpose of n\"ieasurernent tite entire treated surface will be measured.\"(c) :2nd Cr:ai :-T,: apply the 2nd coat of two component acrylic modified,reatiy to-use, flexible cementttious material right angle to the \"1st coat over the glass fibre liad surface. 2nd coat should be applied @0.7 kgl Sqrnt/coat. For the pltrpose of measurement the entire treated surface will be rneasurecl.\" Alte r three days of drying the 2nd coat, therainwaterouilets to be plugged and ponding test to be done for 48 hours to rrjerrtify se epage, leal |
| 68 | Covering of treated surface wrth PCC :- Providing 25 mm thick Cementn Concrete M20(1:\"1.5:3) r\"naintaining slope in alternate 2 mIx 2 mt panelswith aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left shouldbe casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr |
| 69 | Provrding and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge (with 18% GST).Brand:-SikaPolysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent |
| 70 | Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior,sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystallineslurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integralcrystalline slurry : 1 part water) for horizontal surfaces and applyingthe same from negative (internal) side with the help of synthetic fiberbrush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than90% compared with control concrete as per DIN 1048 and resistantto 16 bar hydrostatic pressure on negative side. The crystalline slurryshall be capable of self-healing of cracks up to a width of 0.50mm.The work shall be carried out all complete as per specification andthe direction of the engineer-in-charge. The product performance shallcarry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm |
| 71 | Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior,sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystallineslurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integralcrystalline slurry : 1 part water) for horizontal surfaces and applyingthe same from negative (internal) side with the help of synthetic fiberbrush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than90% compared with control concrete as per DIN 1048 and resistantto 16 bar hydrostatic pressure on negative side. The crystalline slurryshall be capable of self-healing of cracks up to a width of 0.50mm.The work shall be carried out all complete as per specification andthe direction of the engineer-in-charge. The product performance shallcarry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. |
| 72 | Providing and supplying aluminium extruded tubular and otheraluminium sections as per the architectural drawings and approvedshop drawings , the aluminium quality as per grade 6063 T5 or T6 asper BS 1474,including super durable powder coating of 60-80 micronsconforming to AAMA 2604 of required colour and shade as approvedby the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extrudedaluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purposeof payment. |
| 73 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structuraland weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approvedsealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminiumsheet 1 mm thick and of sizes, shapes and profiles, as requiredas per the site conditions, to seal the gap between the buildingstructure and all its interfaces with curtain glazing to make itwatertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and asspecified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structuralglazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directedby the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames,shadow boxes, extruded aluminium section capping for fixingin the grooves of the curtain glazing and vermin proof stainlesssteel wire mesh shall be paid for separately under relevantitems under this sub- head. However, for the purpose ofpayment, only the actual area of structural glazing (includingwidth of grooves) on the external face shall be measured insqm. up to two decimal places.Note:-2. The following performance test are to be conductedon structural glazing system if area of structural glazingexceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department ofScience & Technologies, India. Cost of testing is payableseparately.The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importanceof the work. Performance Testing of Structural glazing systemTests to be conducted in the NABL accredited lab or any otheraccreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 170251. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50kpa to 240 kpa (35psi) upto 2000 ml |
| 74 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included incost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflectivesoft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall bedecided by technical sanctioning authority as per the site requirement. |
| 75 | Extra for openable side / top hung vision glass panels (IGUs) includingproviding and supplying at site all accessories and hardwares for theopenable panels as specified and of the approved make such asheavy duty stainless steel friction hinges, min 4 -point cremonelocking sets with stainless steel plates, handles, buffers etc. includingnecessary stainless steel screws/ fasteners, nuts, bolts, washersetc. all complete as per the Architectural drawings, as per the approvedshop drawings, as specified and as directed by the Engineer- in-Charge. |
| 76 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant)provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technicalsanctioning authority as per the site requirement. |
| 77 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a)Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of allthe structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral coresandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 78 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 79 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface inluding preparing the plastered surface by rubbing wmooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per buiiding specification and drrection of E/i. |
| 80 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 81 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 82 | Providing two coats of synthetic enamel paint of approved shade and make over new wooden surfaces including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes, all complete as per building specifications and direction of E/I |
| 83 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/l. |
| 84 | Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I. |
| 85 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size ,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth. |
| 86 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 87 | Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia |
| 88 | Providing and fixingon wall face unplaqsticised- PVCmoulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,includingjointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.Bend 87.5 degree (110x110x110mm) |
| 89 | Providing and fixingon wall face unplaqsticised- PVCmoulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,includingjointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.Shoe (Plain) (110mm shoe) |
| 90 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete -110mm |
| 91 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating15 cm diameter and weighing not less thaN 440 grams. |
| 92 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60(Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as perrequirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. |
| 93 | Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight ofthe cover to be not less than 58 kg |
| 94 | Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 95 | Labour for laying, fitting and fixing NP2 R.C.C. spu pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leak, proof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complete as per specification and direction of E/I.150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L. |
| 96 | Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I.150mm dia |
| 97 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge100 mm nominal size dia |
| 98 | Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge |
| 99 | Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge |
| 100 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge |
| 101 | DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates)Drilling upto 30 mtr. Depth below G.L. in Rural Area |
| 102 | Disrnantling old plaster and pointing in cement or lime and raking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/|. |
| 103 | Dismantling Pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/| |
| 104 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/| |
| 105 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/| |
| 106 | Taking down chaukhats in doors including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/|dismentling gi sheet |
| 107 | dismentling single section truss |
| 108 | Dismentling steel work manually / mechanically |
| 109 | Bricks (1K+ 7P = 8 KM.) |
| 110 | Coarse Sand(15 KM.) |
| 111 | Stone Chips ( 15 KM.) |
| 112 | Stone Metal ( 15 KM.) |
| 113 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I. |
| 114 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 32mm dia |
| 115 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Vertical - 25 mm dia |
| 116 | Providing and fixing 15mm size C.P. brass pillar cock (Weight not less than 350 gms.) C.I. body brass spindle pillar cock of approved quality as per specification and direction of Engineer-in-charge.C.I. body brass spindle |
| 117 | Cutting chhajja or corince for laying G.I. / C.P.V.C pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortor (1:4) as per specification and direction of E/I. |
| 118 | Making holes in walls for laying G.I. / C.P.V.C pipe and restoring the same after pipe laying as per specification and direction of E/I.125 mm thick wall |
| 119 | Making holes in walls for laying G.I. / C.P.V.C pipe and restoring the same after pipe laying as per specification and direction of E/I.250 mm thick wall |
| 120 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 600mm x 450mm |
| 121 | Glass shel with C.P. brass rail - 450mm x 125mm |
| 122 | C.P. brass towel rail 20mm x 600mm with bracket container |
| 123 | C.P. brass soap dish container medium quality with screw and hinges etc. |
| 124 | C.P. bras liquid soap container |
| 125 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. \"p\" trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I.580mm long (c) With 10 Liter Low Level P.V.C. cistern |
| 126 | Supplying, fitting and fixing 40mm high viterous white glazed earthen E.W.C. with \"p\" trap of Parry/hindustan or any other approved I.S.S. make including supplying and fixing 15 liters C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15mm P.V.C. alkathene pipw 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead o commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approvd paint over a coat of red oxide priming, all complete as per specification and direction of E/I.With \"P\" trap - 10 ltr. Low level PVC cistern |
| 127 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of \"Hindustan \"Parry\" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.Flat back or standing corner (600mmx 350mm) |
| 128 | Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 129 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.For classification of soil item - A135x 0.450 x 0.600 |
| 130 | Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.150mm dia R.C.C. spun pipe |
| 131 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 132 | Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe |
| 133 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm |
| 134 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door - 110x110x110 mm |
| 135 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door - 110x110x110 mm |
| 136 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° - 110mm |
| 137 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever requiredKitchen sink without drain board610x460 mm bowl depth 200 mm |
| 138 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25 mm nominal outer dia Pipes |
| 139 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32 mm nominal outer dia Pipes |
| 140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes |
| 141 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal outer dia Pipes |
| 142 | Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 143 | Providing and fixing PTMT grating of approved quality and colour. C.P. Gratings Circular type - 100mm dia |
| 144 | Supplying the follwing bathroom fittings all complete (VIP)Angular stop cock (Long Thread) |
| 145 | Supplying the follwing bathroom fittings all complete (VIP)Pillar cock (Long neck) |
| 146 | Supplying the follwing bathroom fittings all complete (VIP)Telephone shower with flexible pipe/ Health Façade |
| 147 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 148 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 149 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 150 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L. |
| 151 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(b) From 51.0 M to125.00 M |
| 152 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(c) From126.0 M to150.00 M |
| 153 | Supplying, assembling, lowering and fixing in vertical position in borewell,unplasticizedPVCmediumwellcasing(CM)pipeof required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 154 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \"V\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 155 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 156 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 157 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 158 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etcall complete job as per direction of E/I. |
| 159 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etcall complete job as per direction of E/I. |
| 160 | Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 161 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB. Group C |
| 162 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB/HPL/Anchor |
| 163 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB/HPL/Anchor |
| 164 | Supply & fixing 20A SPN MCB Industrial Socket Outlet( for AC+ others): Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps \"C\" series, SP MCCB, in sheet steel enclosure, on surface or in recess withchained metal cover for socket out let and complete with connections, testing and commissioning etc as required. |
| 165 | S/F 20Ams415 volts TPN MCB Industrial Socket: Supply and fixing odf 20 Amps, 415 volts, SPN industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve , TPN, MCB. In sheet steel enclosure, on surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioningetc as required. |
| 166 | Wiring for power plug with 2x4 sqmm FR PVC insulated copper conductor single core cable in recessed PVC conduit alongwith 1 No. 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 167 | Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 168 | Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 169 | Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x6 Sqmm + 1x6 sqmm earth wire-PDB DBs |
| 170 | Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.4x4 Sqmm + 2x4 sqmm earth wire( 32A 3ph,I/S)+LDBs |
| 171 | Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.4x6 Sqmm + 2x6 sqmm earth wire- PDBs |
| 172 | Providing & fixing : Porviding and fixing of MV danger notice plate of 200mmX150 mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 173 | Supplying and fixing Modular type blanking plate-Supplying and fixingmodular blanking plate on existing modular plate switch box excluding modular plate etc. as required. |
| 174 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 175 | Supply fixing(S/F) following sizes ofmedium class PVC Conduit along with accesseories in surface/recess including cutting the wall and making good the same in core recessed conduit etc. as required. Make-Havells/Polycab/ Indo Asian20mm |
| 176 | Supply fixing(S/F) following sizes ofmedium class PVC Conduit along with accesseories in surface/recess including cutting the wall and making good the same in core recessed conduit etc. as required. Make-Havells/Polycab/ Indo Asian25mm |
| 177 | S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections butexcluding modular plate etc as required.5/6 AMPS, one way switch |
| 178 | S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections butexcluding modular plate etc as required.5/6 Amps, 3 pin socket outlet |
| 179 | Ceiling Rose: Supplying and fixing 3 pin,5 amp ceiling rose on existing junction box/wooden block including connection etc as required. |
| 180 | S/F Electronic Musical Call bell: Supplying and fixingelectronic musical call bell suitable for D.C/A.C, single phase 230 volt, complete as required. |
| 181 | ITC fluorescent fitting directly on surface :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor. |
| 182 | ITC fluorescent fittingwith down rods :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, including supplying and fixing ball and socket arrangement, 2 nos. down rods of 20mm dia stee. |
| 183 | ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required. |
| 184 | Numbering of Fan/ fittings: Numbering of ceiling fan/ exhaust fan/ fluorescent fitting as required. |
| 185 | Supplying and fixingthe follwing way Three Pole pole and Neutral Sheet steel M.C.B distribution board, 415 volts in recess, completed with tinned copper busbar, neutral bus bar, earth bus bar, din bar, hinged front acrylic cover from MCB Knob detachable gland plate, interconnection including earthing etc. as required(without MCB/RCCB/Isolator). Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor4 way(4+12) Double door Horizontal type-Lighting( Ground Floor =1, First floor=2) and Power( FF=2) |
| 186 | S/F SP MCB DB: Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor8 ways Double Door Parking + common |
| 187 | S/F SP MCB DB: Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor12 ways Double Door (power-ground floor =1) |
| 188 | S/F \"C\" series SP MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor6/32A Single Pole |
| 189 | S/F \"C\" series SP MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor32A TPN for lighting |
| 190 | S/F \"C\" series SP MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor40A DPfor Lighting and outer light |
| 191 | S/F \"C\" series SP MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor63A DPfor power |
| 192 | S/F \"C\" series SP MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor63A TPNfor power |
| 193 | S/F \"C\" series SP MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB / HPL /Anchor32A TPN MCB - for industrial socket |
| 194 | PVC/ XLPE Armoured Al Cable: Supply of followingPVC/XLPE insulated PVC sheathed, heavy duty , armouredelectrical cable with aluminium conductor for working voltage upto and including1.1 kV grade( Confirms to IS :1554, part-1).3.5CX70 sq. mm armouredAL Cable. |
| 195 | 1.1kV Cable End Termination: suppluingand fixingindoor cable endterminationwith brass double compression gland and AL lugsof following sizeAl armoured cables.3.5Cx70 sq.mm |
| 196 | MV cable Laying upto 95 Sqmmin ground without sand and cover: Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size notexceeding 95 sq.mm. direct in groundbut excluding , sand cushioning, protective coveringas required. |
| 197 | MV cable Laying upto 185 Sqmmin ground without sand and cover: Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size notexceeding 185 sq.mm. direct in groundbut excluding , sand cushioning, protective coveringas required. |
| 198 | Copper Earth Plate Elecrode:- Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but with charcoal or cock and salt) complete etc. as required.Lightning Conductors=2 nos + Panels=1 no). |
| 199 | S/L 8 SWG copper wire in ground :- Supplying and laying 8SWG copper wire at 0.50 metere below ground level for conductor earth electrode, including soldering etc. as required. |
| 200 | Providing and Fixing Lightning Conductor Finial : P/F of lighting conductor finial, made of 25mm dia 300mm long GItube, having single prong at top, with 85mm dia 6mm thick GI base plate including holes etc. complete as required. |
| 201 | GI lightning conductor tape in horizontal run - Providing and fixing of GI tape 20mm X3mm thick on parapet or surface of wall for lighting conductor etc complete as required. |
| 202 | GI lightning conductor tape in Vertical run - Providing and fixing of GI tape 20mm X3mm thick on parapet or surface of wall for lighting conductor etc complete as required. |
| 203 | Supply ofBLDC Ceiling Fan: Supplying and fitting ofBLDC5 Star, 32W, 1200 mm Sweep AC ceiling fan ,including connection with 1.5 sq mm copper wire, down rodof standared length(upto 30cm) with all accessories as required. Make :- Polar/Bajaj/Crompton / Havells / GEC. |
| 204 | Supply of Wallmounted Fan: Supplyof 16\"(400mm), 230V AC wall/cabin fan including fixing the bracket, making , connection testing, commissioning etc as required( Make- Polar/Bajaj/ Havells/Crompton) |
| 205 | Supply of Metal Exhaust Fan 12\"(300mm): Supply of12\"(300mm), 230V ACmetal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required( Make- Polar/Bajaj/ Havells/Crompton) |
| 206 | LED tube with Batten 20W/22W : Supplying and fixingof wall mountedLED 20W /22W tube + batten and electronic driverand accessories as required. ( Make -Wipro/Bajaj / Havells/ Philips) |
| 207 | LED Bulb 9W/10W : Supplying and fixingofLED 9W /10W bulb and accessories as required. ( Make -Bajaj / Havells/ Philips) |
| 208 | LED Floodlights 120W :Environmental friendly, new generation,aesthetically designed, ultra modern LED floodlightluminaire with high diecast housingand IP66 protection.( make: Wipro /Havells/Bajaj/ Philips) |
| 209 | Bulk head 9/10 LED Fitting: Supply and fixing of 9/10W LED, surface mounted bulk head PVE water proof housing forindoor/ ourdoor.( Make-Havells /Bajaj/Wipro/Philips) |
| 210 | 50kVA DG set :Supply, fitting, fixing, errection and commissioning along with civil foundation work of 50kVA D.G. Set, 415 Volts, 3 Ph. Silent Diesel Engine driven generating set as per IS:1460 & IS : 13018 and alternator as per IS:13364 complete with sound proof company make canopy (Acoustic Enclosure suitable for 50 kVA D.G. Set.) with breaker panel (automatic Control Panel) and civil foundation work as per the norms of 82.5 KVA Silent D.G. Set with suitable arrangement for Al./Ar./C etc as required. (Make:- Sterling and Wilson Powergen Private Limited with MTU Engine SDGSC - 3 Cotroller / Kirloskar (GREEN) / Jakson Limited / Mitsubishi / Cater Pillar) |
| 211 | Main LT Panel for 50kVA DG :- Supplying, designing, manufacturing, installation, testing and commissioning of LT Panel of 14 SWG CRCA sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel size - 100 mm x 100 mm x 6 mm with proper lifting arrangement effecting proper connection of all incomers and outgoing(IP-43) fully compartmentalizedcubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 50 kA with front operated construction including separate fabrication arrangement for fixing MCCBs and Bus Coupler. The sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs. The panel includes 415V, 150A, 3Ph, 50kA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) Aluminium, Earth Busfor main supply and 150A Al bus bar with earth bus bar for DG supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing Feeders complete in all respects. All inter connections shall be made with 2.5 4, 6, 10 Sq mm PVC Cu. wire.All incomer MCCB and bus coupler shall be mechanically operated . All 4 pole MCCB with thermomagnetic based release must have following character:Icu=100% Ics with adjustable S/C and O/LProvision for inbuilt earth leakage module & provision for inbuilt measuring unit.The panel consisting of the followings4 pole MCCB 125 A,35 kA with fixed thermal magnetic setting- 2 nos( 1 no for DG and 1 for JSEB)125 amps, 4 pole ChangeoverDP 400 MCB-4 nosTPN40 MCB-4 nosTPN 63 MCB-3nosElectronic On timer delay -30 sec200 amp 415 V heavy duty three phase with neutral busbar chamberIndicator switch- 6 nosSelector switch- 3 nosVoltmeter- 3 nosAmmeter-3 nosC.T. Coil-6 nos |
| 212 | GST @ 12% |
| 213 | Labour Cess@1% |
AI Tender Summary
Tender Timeline
Apr 13, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedApr 20, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedApr 21, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender