Department Of Tourism has published Up Gradation Of Building At Amusement Park By Way Of Electrification And Cabling Link Between Yatri Niwas Panel And Amusement Park Panel. Cno26 Up Gradation Of Building At Amusement Park By Way Of Electrification And Cabling Link Between Yatri Niwas Panel. Submission Date for this Tender is 20-04-2022. Electrification Work Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supplying and drawing following size of frls pvc insulated conductor single core cable in the existing surface/recessed steel/pvc conduit as required |
2 | 2x2.5sqmm+1x2.5sqmm earth wire |
3 | 2x4sqmm+1x4sqmm earth wire |
4 | 2x6sqmm+1x6sqmm earth wire |
5 | 2x10sqmm+1x10sqmm earth wire |
6 | Providing and fixing of 1200mm ceiling fan white colour with power consumption not to be higher than 50watt,240v,50hz |
7 | Providing and fixing of 4 feet led based tube light |
8 | supplying and fixing of following size of medium class pvc conduit along with accessories like bends flexible pipe etcin surface/recess including cutting the wall and making it good |
9 | 25mm |
10 | 32mm |
11 | Supply and fixing following size /modules, GI box along with modular base and cover plate for modularswitches in recess etc as required |
12 | 4 module |
13 | 6 module |
14 | 8 module |
15 | 12 module |
16 | Supplying and fixing the following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc.as required |
17 | 5/6 amp switch |
18 | 15/16 amp switch |
19 | 3 pin 5/6 amp socket |
20 | 6 pin 15/16 amp socket |
21 | Supplying and fixing of following ways surface/recess mounted vertical type 415 volt ,TPN MCB distribution board of sheet steel,dust protected duly powder painted inclusive of 200AMP tinned copper bus bar common neutral linl earth bar din bar for mounting MCBs(but without MCBs and incomer) as required 4 way(4+12),double door |
22 | Supplying and fixing following rating double pole/single pole and neutral240 voltin the existing MCB DB complete with connections, testing and commissioning etc as required Havells,Anchor,L&T |
23 | 40 amp |
24 | 63amp |
25 | Providing and fixing of double door machine fabricated busbar panel consisting of 04 number of busbar of capacity 300 amp with separate space for 32amp tpn and 63amp tpn each and panel must have 04 legs to be grouted on ground with proper foundation of ratio 1:2:4 (cement: sand: aggregated stone),including cost of aluminium thimbles of 50sqmm 08 number ,aluminium thimbles of 10sqmm 08 number |
26 | Providing and fixing of double door machine fabricated busbar panel consisting of 04 number of busbar of capacity 500 and panel must have 04 legs to be grouted on ground with proper foundation of ratio 1:2:4 (cement:sand:aggregated stone) including cost of aluminium thimbles of 185sqmm 08 number |
27 | Providing and fixing of double door machine fabricated busbar panel consisting of 04 number of busbar of capacity 500 amp with separate space for 315amp mccb and panel must have 04 legs to be grouted on ground with proper foundation of ratio 1:2:4 (cement:sand:aggregated stone) including cost of aluminium thimbles of 185sqmm 08 number,including cost of indiacting voltmeter and amper meter |
28 | Providing and fixing of 1.5 mtr bracket of iron type with fixing of 60watt street light and this to be fixied on prelaid pole /building top as directed by site engineer |
29 | Providing and fixing of 90/100 watt flood light |
30 | Providing and fixing of 1.5sqmm 3 core copper based flexible cable |
31 | Providing and fixing of 10sqmm twin core aluminium cable |
32 | Providing and fixing of 185sqmm xlpe pvc sheathed armoured cable in suitable size of hdpe /dwc pipe in underground /overhead on pole as per site condition from the amusement DG panel to yatri niwas DG panel |
33 | Providimg and fixing of 25 sqmm 3,5 core xlpe pvc sheathed aluminium aroured cable to be laid underground in suitable size of dwc/hdpe pipe including cost digging trnch and refilling of same |
34 | Providing and fixing of 10sqmm 4core xlpe armoured cable insuitable size of hdpe pipe to be laid under ground including cost of digging trench and refilling of same and cutting of tile and making it same as before digging |
35 | Providing and fixing ofpost top garden lanterns of 30 watt IP65 ,240 volt ,50hz including 2.0 mtrGI PIPE with silver colour of 80mm dia to be grounted on ground with cement concrete ration of 1:2:4(cememt:sand:aggregated stone) INCLUDING COST OF JUNCTION BOX and required MCB of 6 amp capacity with 02 pole connector |
36 | Providing and fixing of 12volt,36Ah battery lithium ferro phosphate battery |
37 | Repainting of existing panels with existing quality and colour of panels |
38 | Providing and fixing of 32 amp tpn |
39 | Providing and fixing of 63 amp tpn |
40 | Providing and fixing of 315ampere MCCB |
41 | Repair of flood light by way of replacing its driver and other things like connecting wire connector etc |