| 1 | M&L for removing from existing position, window/Splittype A/C unit 1/1.5 / 2.0 Ton capacity of any makefor servicing the same by complete cleaning the dust including supply and replacement of damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor by oiling/greasing, changing of damaged knobs, painting the old painted surfaces with one coat of synthetic enamel paint, setting of grills alignment complete including refixing in original position, testing & commissioning all as directed by engineer-in-charge. |
| 2 | All as per item No. 01 above but for5/5.5 Ton ductable split type air conditioner three phase |
| 3 | All as per item No. 01 above but for11 Ton Package type air conditioner three phase |
| 4 | M&L for taking out rotary type compressor unit (uncut) from the split type Air Conditioner of any make, 1 ton capacity and replacing the sealed unit as per existing model with reconditioned sealed unit including the following all as specified and as directed. (a) Connection to suction/discharge pipe with necessary repair and brazing.(b) Replacing the capillary tubes of existing size and copper liquid filter.(c) Flushing of entire system before gas charging.(d) Gas charging and testing after completereplacement incl installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed. |
| 5 | All as per item No. 04 above but for1.5 ton capacity |
| 6 | All as per item No. 04 above but for2 ton capacity |
| 7 | All as per item No. 04 above but for 5/5.5ton ductable split type Air conditioner three phase |
| 8 | All as per item No. 04 above but for 1.5ton split type Air conditioner three phase suitable for Refrigeration gas of R32 |
| 9 | All as per item No. 04 above but for 2.0ton split type Air conditioner three phase suitable for Refrigeration gas of R32 |
| 10 | M&L for taking out rotary type compressor unit (uncut) from the Window type Air Conditioner of any make, 1.5 ton capacity and replacing the sealed unit as per existing model with reconditioned sealed unit including the following all as specified and as directed. (a) Connection to suction/discharge pipe with necessary repair and brazing.(b) Replacing the capillary tubes of existing size and copper liquid filter.(c) Flushing of entire system before gas charging.(d) Gas charging and testing after completereplacement incl installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed. |
| 11 | All as per item No. 10 above but for2 ton capacity |
| 12 | M&L for taking out Condenser unit from the split type Air Conditioner of any make and type,1/ 1.5 ton capacity and replacing the same with copper Condenser unit including necessary connection and testing after complete replacement as specified and as directed. |
| 13 | All as per item No. 12 above but for2 ton capacity |
| 14 | M&L for taking out Condenser unitfrom the Window type Air Conditioner of any make and type,1.5 ton capacityand replacing the same with copper Condenserunit including necessary connection andtesting after completereplacementasspecified and as directed. |
| 15 | All as per item No. 14 above but for2 ton capacity |
| 16 | S&F in repair of thermostat switch with knob for any make Window type Air Conditionerof capacity 1.5/2 Ton including necessary electrical connection, lugs, insulation tape etc all as specified and as directed. |
| 17 | M&L for insulation of split type AC of capacity 1/1.5/2 Ton complete all as specified and as directed. |
| 18 | S&F in repair Selector switch suitable for Window type AC 1.5/ 2 Ton capacity as per existing make/ model complete all as specified and directed. |
| 19 | S&F in repair of PVC drain pipe of 15 mm dia 1.5 mtr length suitable for Split AC 1/ 1.5/ 2 toncapacity including necessary connection and fittings etc complete all as specified and as directed. |
| 20 | S&F in repair ofPVC pipe 63 mm dia for protection of insulation of split AC including necessary fittings all as specified and as directed. Make : Prince/Astrol |
| 21 | S&F in repair of thermostat switch with knob for any make Ductable split Air Conditioner of capacity 5/ 5.5 Ton including necessary electrical connection, lugs, insulation tape etc all as specified and as directed. |
| 22 | S&F in repair of overload protector relay suitable for Window/ split type AC of 1/ 1.5/ 2.0ton capacity including necessary electric connections, lugs, insulation tape etc all as specified and as directed. Make: AEI/ Shriram |
| 23 | M&L for taking out defective burnt fan motor from the Split Air Conditioner of capacity 1/ 1.5/ 2 Ton, dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor,re-assembling the motor and testing the motor at medium and full load complete all as directed. |
| 24 | All as per item No. 23 above but rewinding for fan motor of5/5.5 Ton ductable split air conditioner any make and model. |
| 25 | S&F in repair blower motor for 1/1.5/2 ton capacity split AC all as specified and as directed. Make: Suitable for carrier /Voltas /LG /Blue star/ Amtrex spilt AC as per manufactures make. |
| 26 | All as per item No. 25 above but rewinding for blower motor of5/5.5 Ton ductable split air conditioner any make and model. |
| 27 | M&L for taking out defective burnt blower motor from the Window type Air Conditioner of capacity 1.5/2 Ton , dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor,re-assembling the motor and testing the motor at medium and full load completeall as directed. |
| 28 | S&F in repair remote suitable for Window/split type AC 1.5/2 Ton capacity as per existing make/ model complete all as specified and directed. |
| 29 | S&F in repair remote circuit suitable for split type AC 1/1.5/2 Ton capacity as per existing make/ model complete all as specified and directed. |
| 30 | S&F in repair remote circuit suitable for Window type AC 1.5/2 Ton capacity as per existing make/ model complete all as specified and directed. |
| 31 | S&F in repair contactor for split type A, 1/ 1.5/ 2 Ton capacity as per existing make and capacity/ model etc complete all as directed. |
| 32 | S&F in repair of air filter set suitable for split type AC of 1/1.5 / 2 tone capacity of any make and type all as specified and as directed. |
| 33 | S&F in repair of air filter set suitable for Split type AC of 5/ 5.5 tone capacity of any make and type all as specified and as directed. |
| 34 | S&F in repair of air filter set suitable for Window type ACof 1.5 / 2 tone capacity of any make and type all as specified and as directed. |
| 35 | S&F in repair3 core, 1.5 Sq mm copper flexible cable for water coolers / Window type ACs / Split ACs / Refrigerator/ Deep freezer etc complete all as directed. |
| 36 | All as per item No. 35 above but flexible copper cable 3 core, 4 Sq.mm. |
| 37 | All as per item No. 35 above but flexible copper cable 3 core, 2.5 Sq.mm. |
| 38 | S&F in repair 240 V, 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp SP.Make: Legrand Cat No: 6078 41 or equivalent in Schneider / L&T / ABB / Siemens. |
| 39 | S&F in repair 4-8 mfdrunning capacitor for window & Split AC of1/1.5/2 Ton capacity including necessary electrical connections, lugs, insulation tape etc all as specified & as directed.Make: SIMCAP, Unicop, Usha, Epcos |
| 40 | All as per item No. 39 above but 36 mfd Capacity for AC 1.5 ton. |
| 41 | All as per item No. 39 above but 45 mfd Capacity for AC 2 ton. |
| 42 | All as per item No. 39 above but 50 mfd Capacity for AC 2 ton. |
| 43 | S&F in repair 80-100 mfd startingcapacitor for window and Split AC of any make and cap and all as specified and as directed including necessary electrical connections, lugs, insulation tape etc all as specified and as directed. Make: Tesla, Krishnomic, Keltron, BHEL. |
| 44 | All as per item No. 43 above but 100-120 mfd Capacity |
| 45 | S&F in repair of swing motor for split type AC 1/1.5/2 ton capacity of different types and makes Each make of motor shall be same as original all as specified and as directed. |
| 46 | S&F in repair of copper tubing including brazing, flaring & testing of size 1/2\" and 5/8\" in required length including PVC insulation complete all as directed. |
| 47 | M&L for removing water cooler of 40/80/150 Ltr capacity from existing position after disconnecting from inlet water connection and plugged the water line and servicing the water cooler bycleaning the water tank cleaning the internal parts by blower and removing the burned wires and replacing the same with proper size copper conductor cable , repair / replacement of damaged hinges, drain pipe up to 1.5 m long , replacement of rusted nuts and bolts tightening the all connections refixing in original position connecting the water inlet and testing and complete to the entire satisfaction allas directed and specified by the Engineer-in-charge. (refrigerant filling will be measured and paid separately) |
| 48 | M&L for taking out old rotary compressor unitfrom water cooler storage type, 40 Ltr/hr cooling capacity and replacing the sealed unit with new sealed unit of same cap & model including the following:- Make: Tecumseh Kirloskar 4440/436 /443(a) Connection to suction/discharge pipe with necessary replacement and brazing(b) Replacing capillary tube of existing size and copper liquid filters (c) Flushing of entire system before gas charging (d) Gas charging and testing after complete replacement including installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed. |
| 49 | All as per item No. 48 above but for water cooler storage type 60/150 liter per hour cooling capacity. |
| 50 | S&F in repair over load protector relay of water cooler of capacity40/60/150 Ltr make Usha/Blue star including necessary electrical connection, lugs, insulation tape etc all as specified and as directed. |
| 51 | S&F in repairPTMT float valve assembly 15 mmbore with plastic ballincluding GI nipple 3 inch longfor fixing float valve for water cooler all as specified and as directed. Make: Prayag / Prince / Kisan. |
| 52 | S&F PVC connection pipe both end brass joint with rubber washer 45 cm long. |
| 53 | S&F in repair 15 mm dia concussive push button taps of cast copper alloy, screwed for iron pipe for water cooler all as specified and as directed. |
| 54 | S&F in repairof thermostat switch with knob for water coolerofcapacity 40/80/150liters per hour (Usha/Blue Star)including necessary electrical connection, lugs, insulation tape etc all as specified and as directed. Make : Indfoss/Ranutrol |
| 55 | M&L for taking out defective burnt motor from the water cooler of any size/ capacity, dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor,re-assembling the motor and testing the motor at medium and full load completeall as directed. |
| 56 | S&F in repair fan blade of water cooler of 40/80/150 liters per hour capacity suitable for make Usha/ Blue Star all as specified and as directed. |
| 57 | S&F in repair fan motor suitable for water cooler of 40/ 80/100 liters capacity complete all as directed. Make: AEU/MEI. |
| 58 | S&F in repair 10 mfdrunning capacitor for water cooler any capacity including necessary electrical connections, lugs, insulation tape etc all as specified & as directed.Make: SIMCAP, Unicop, Usha, Epcos |
| 59 | S&F repair 40-60 mfd startingcapacitor for water cooler of any make and cap and all as specified and as directed including necessary electrical connections, lugs, insulation tape etc all as specified and as directed. Make: Tesla, Krishnomic, Keltron, BHEL. |
| 60 | Taking down Existing Split AC with pumping down refrigeration gas of any type using vaccum pump and transporting to another location and refixing with proper anchoring bracket including recharging gas duly tested and as directed by Enr in charge |
| 61 | M&L for taking out rotary type compressor unit (uncut) of refrigerator for 286/300/310 Ltr capacity (Make : Godrej / Kelvinator) and replacing the sealed unit with reconditioned sealed unit of same brand including the following all as specified and as directed. Make:- Tecumesh - 1343/ 1350/ 358/ Kirloskar/ Godrej(a) Connection to suction/discharge pipewith necessary replacement and brazing. (b) Replacing capillary tube of existing size and copper liquid filters.(c) Flushing of entire system before gas charging.(d) Gas charging and testing the unit to the entire satisfaction. |
| 62 | S&F in repair of suitable box type relay with over load protector refrigerator of capacity 286/ 300/ 310 liters capacity of different make and size including necessary connections, lugs, insulation tape etc all as specified and as directed. Make: Whirlpool/ Godrej |
| 63 | S&F in repairof cooling coil for refrigerator capacity 286/300/310 Ltrs all as specified and as directed. |
| 64 | Supplying and charging refrigeration gas F-22 or R-22 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed. |
| 65 | Supplying and charging refrigeration gas R-32 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed. |
| 66 | Supplying and charging refrigeration gas F-134A including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed. |
| 67 | M&L for taking out Condenser unitfrom the Refrigerator of any make,286/300/310 ltr capacity and replacing the same with copper Condenser unit including necessary connection and testing after complete replacement complete all as specified and as directed. |
| 68 | S&F in repair of thermostat switch with knob for any make refrigerator of capacity 286/ 300/ 310 liters capacityincluding necessary electrical connection, lugs, insulation tape etc complete all as specified and as directed. Make: Indfoss/ Ranutrol |