| 1 | Please Note that Quoted rates are inclusive of all taxes,duties, royalties, labor, transportation. Nothing Extra shall be paid separtely. |
| 2 | Supply installation testing and commissioning of Oil seals of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 3 | Supply installation testing and commissioning of Piston Rings of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 4 | Supply installation testing and commissioning of Pressing Bush of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 5 | Supply installation testing and commissioning of Distance Ring of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 6 | Supply installation testing and commissioning of Gasket of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 7 | Supply installation testing and commissioning of Spherical Roller Bearing with Cylindrical Bore of model 22308E SKF of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 8 | Supply installation testing and commissioning of Gear set of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 9 | Supply installation testing and commissioning of Suction Filters of STP (Sewage Treatment Plant) Blowers. Make of Blower - Everest Blower, Model No. 610 Capacity. 630 M3/hr.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 10 | Supply of Sodium Hypochlorite ( liquid) for STP. |
| 11 | Supply of Polyaluminum Chloride (PAC) (Powder) for STP. |
| 12 | Supply of Aluminim Sulphate (Alum) Powder for STP. |
| 13 | Supply installation testing and commissioning of Spherical Roller Bearing with Cylindrical Bore of model 22308E SKF of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 14 | Supply installation testing and commissioning of Gear set of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 15 | Supply installation testing and commissioning of Oil seals of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 16 | Supply installation testing and commissioning of Suction Filters of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 17 | Supply installation testing and commissioning of Piston Rings of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 18 | Supply installation testing and commissioning of Distance Rings of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 19 | Supply installation testing and commissioning of Pressing Bush of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 20 | Supply of blower greece (Grade - Ap 3 greece) of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr |
| 21 | Supply of lubrication gear oil (Grade - Ep 90 gear oil) of ETP (Effluent Treatment Plant) Blowers. Make of Blower - Airvak Blower Pvt. Ltd., Model No. 500 Capacity. 500 M3/hr |
| 22 | Supply of lubrication oil SAE 30 grade for cooling tower motors |
| 23 | Chillers |
| 24 | Supply of Refrigerant gas R 134a for centralised centrifugal chillers. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 25 | Supply of Refrigerant gas R 22 for hiwall type air condition units. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 26 | Supply of Nitrogen gas for air condition units leak testing,The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 27 | Supply of 62 kg empty cylinders for refrigerant gas filling and storage pupose for a period of min 15 days. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 28 | Descaling of 470 TR condenser tubes (Approximate 500 Nos. of tubes) of chiller model KSC 087 by supply of acidic chemical of suitable ph level as per the condenser Approach, rotate the acid in the condenser tubes (min 12 hours) and clean it by using brush attached with the motor, repeat the above procedure until the condenser approach reaches a maximum of 4 degree. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 29 | DX Units compressors |
| 30 | Supply installation testing and commissioning of DX hiwall type of 3 Tr capacitycompressor (Copeland Scroll 3 phase), work includes leak testing with nitrogen gas and then vacuum upto the level of OEM recommendations and filling of refrigeranr gas. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 31 | Supply installation testing and commissioning of DX hiwall type of 2 Tr capacitycompressor (Copeland Scroll Single phase), work includes leak testing with nitrogen gas and then vacuum upto the level of OEM recommendations and filling of refrigeranr gas. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 32 | Supply installation testing and commissioning of DX hiwall type of 1.5 Tr capacitycompressor (Copeland Scroll Single phase), work includes leak testing with nitrogen gas and then vacuum upto the level of OEM recommendations and filling of refrigeranr gas. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 33 | Supply installation testing and commissioning of DX hiwall type of 2 Tr capacitycopper condenser coil, work includes leak testing with nitrogen gas and then vacuum upto the level of OEM recommendations and filling of refrigeranr gas. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 34 | Supply installation testing and commissioning of DX hiwall type of 2.5 Tr capacitycopper condenser coil, work includes leak testing with nitrogen gas and then vacuum upto the level of OEM recommendations and filling of refrigeranr gas. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 35 | Supply installation testing and commissioning of DX hiwall type of 3.0 Tr capacitycopper condenser coil, work includes leak testing with nitrogen gas and then vacuum upto the level of OEM recommendations and filling of refrigeranr gas. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 36 | Supply installation testing & commissioning of chilled water 2.0 Tr cassette AC drain pump with float switch. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 37 | Supply of 10 Feet Step Ladder (Silver) of Item dimensions - 3.11 x 0.67 x 0.2 Meters (L x W x H), Material: aluminium, color: silver.Heavy duty professional aluminium step ladder; heavy duty moulded utility top to hold tools and a hook to hang a bucket; aluminium spreader link with hand grip for easy one-handed carry and close; wide 3 inch slip resistant serrated aluminium steps for safe climbing; paint tray slot, can hook, 3 tool holes, drill hole, pint, quart and gallon paint can |
| 38 | Motor Rewinding work |
| 39 | Rewinding of electric motor of capacity 25 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 40 | Rewinding of electric motor of capacity 20 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 41 | Rewinding of electric motor of capacity 15 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 42 | Rewinding of electric motor of capacity 10 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 43 | Rewinding of electric motor of capacity 7.5 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 44 | Rewinding of electric motor of capacity 5 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 45 | Rewinding of electric motor of capacity 2 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 46 | Rewinding of electric motor of capacity 1 HP.The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 47 | Cooling Tower |
| 48 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details arePVC fill sheets MX75-8.1 LEV ( 4* 12 Feet )Part No. P85-4289-13 |
| 49 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details arePVC fill sheets MX75-8.1 LEV ( 4* 12 Feet )Part No. P85-4289-14 |
| 50 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details areFill retainer cap |
| 51 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details areTarget nozzles |
| 52 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details areLubricating oil for cooling tower motors SAE 30 |
| 53 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details areTube 2 \" OD * 20 GA Thk * 600 ERW GI |
| 54 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details areTube 2 \" OD * 20 GA Thk * 670 ERW GI |
| 55 | Supply of cooling tower spare materials of model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur, item details areUni-o strip (For Leakage recovery) |
| 56 | Labour Charges for existing PVC fills cleaning and reinstallation of good fills and installation of new PVC fills with its accessories like fill retainer cap, tubes uni ostrip and target nozzles by dismantling the entire cooling tower & Etc. The cooling tower details are, Model no. 6151, TB/ Sr No. 12-2F0078 and make - Paharpur (Cross flow). |
| 57 | Cooling Tower water treatment chemicals |
| 58 | Supply of scacil 9800 (Regular Treatment) |
| 59 | Supply of scacil 9240 (Regular Treatment) |
| 60 | Supply of scacil 9020 (Regular Treatment) |
| 61 | Supply of Bionil 9030 (Regular Treatment) |
| 62 | Supply of Ph reducing Acid (H2SO4) |
| 63 | Pumps reapairing Work |
| 64 | Charges Towards 100 HP motor Preventive servicing (cleaning of coil, repainting completely, greasing and Etc.), the work should be done on site only. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 65 | Charges Towards 75 HP motor Preventive servicing (cleaning of coil, repainting completely, greasing and Etc.), the work should be done on site only. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 66 | Supply of 100 HP motor bearing of model no. of bearing 6316 2Z C3 80mm I.D Plain Deep Groove Ball Bearing, 170mm O.D ( Make - SKF). The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 67 | Supply of 75 HP motor bearing (Model of bearing 6310 2Z C3 50mm I.D Plain Deep Groove Ball Bearing, 110mm O.D ( Make - SKF). The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift, transportation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 68 | Charges towards Installation of Bearings for 100 HP and 75 HP water pumps & motors wherever applicable & alignment of motor and pumps. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 69 | Rubber bellows - 200 mm diaSupply, Installing, testing and commissioning ofPN 16 rating Flexible Pipe Connections (Expansion bellows) with connecting rod, in position complete with flanges,bolts,nuts, including gaskets etc.conforming to specifications |
| 70 | Rubber bellows - 250 mm diaSupply, Installing, testing and commissioning ofPN 16 rating Flexible Pipe Connections (Expansion bellows) with connecting rod, in position complete with flanges,bolts,nuts, including gaskets etc.conforming to specifications |
| 71 | Valves & Strainers |
| 72 | Supply installation testing and commissioning of valve package of pipe size 25 mm dia with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 73 | Butterfly valves :- 250 mm dia- Insulation indoor duty Supply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 74 | Manual Butterfly valves - 200 mm dia. - Valves with insulationSupplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 75 | Butterfly valves :- 125 mm dia- Insulation indoor duty Supply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 76 | Butterfly valves :- 100 mm dia- Insulation indoor duty Supply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 77 | Butterfly valves :- 80 mm dia- Insulation indoor dutySupply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. Valves shall be PN-10 rating, the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 78 | Butterfly valves :- 65 mm dia- Insulation indoor dutySupply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 79 | Butterfly valves :- 50 mm dia- Insulation indoor dutySupply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 80 | Butterfly valves :- 40 mm dia- Insulation indoor dutySupply, fixing, testing and commissioning of followingvalves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specification. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring, matching flanges,nuts & Bolts PN 16 pressure rating for chilled water/hot water circulation as specified,the quoted rate inclusive of matching flanges, nuts and bolts etc. |
| 81 | NRV valve 100 mm dia- NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. |
| 82 | NRV valve 125 mm dia- NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. |
| 83 | NRV Valve 200 mm dia - NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. |
| 84 | NRV Valve 250 mm dia - Supply of dual plate type non return valve - PN-16 ratings for water lines. The body is made of cast iron/stainless steel, the operating temperature is between 0 to 90 degree celsius and the pressure is around 16 bar, of Following Sizes. Location:-Chiller pumps and chiller (Inlet & Outlet) |
| 85 | Ball valve 1/2\" inch diameter- Supply & installation of brass type ball valve. All complete as per specifications of following sizes. |
| 86 | Ball valve 1\" inch diameter- Supply & installation of brass type ball valve. All complete as per specifications of following sizes. |
| 87 | Fridge work |
| 88 | Supply and installation of compressor (Including Nitrogen leak test, vacuum and gas charging), the capacity of the refrigerator is 1200 liters. |
| 89 | Gas charging (Including Nitrogen leak test, vacuum and gas charging), the capacity of the refrigerator is 1200 liters. |
| 90 | Supply and installation of sub zero controller with sensor for the refrigerator, the capacity of the refrigerator is 1200 liters. |
| 91 | Supply and installation of Stainless Steel Door of refrigerator of capacity 1.2 KL ( The size of the door is 500*500*25 mm thick. |
| 92 | Fans |
| 93 | Inline fans - 600 CFM /10 mm SPSupply of Toilet exhaust ducted inline fans of 10 mm static presuure of water column. The capacity of fans are min 600 CFM. The body is made of MS. The fan is compleyetly single phase and not more than 200 Watts. |
| 94 | Inline fans - 1000 CFM /10 mm SPSupply of Toilet exhaust ducted inline fans of 10 mm static presuure of water column. The capacity of fans are min 600 CFM. The body is made of MS. The fan is compleyetly single phase and not more than 200 Watts. |
| 95 | Axial Type FansSuppy and installation axial type exhaust fans details of requirement are1) Sweep size - 200 mm2)No of Blades - 3/4/5 Each any of three3)Motor Speed - Normal Speed at about 1400 RPMBody and Blades - MetallicAir Delivery - 480 CFMNoise Level - 40dB To 50 dBMax Power Consuption-40 watts/230Volts/50 Hz |
| 96 | Axial Type FansSuppy and installation axial type exhaust fans details of requirement are1) Sweep size - 300 mm2)No of Blades - 3/4/5 Each any of three3)Motor Speed - Normal Speed at about 1400 RPMBody and Blades - MetallicAir Delivery - 800 CFMNoise Level - 50dB To 61 dBPower Consuption - 50 watts/230Volts/50 Hz |
| 97 | Supply and installation of high flow 400 mm diameter swipe wall mounted 3 PVC blades 3 speed controll fans. Watt – 50-60 Frequency 50Hz. (Make : Crompton greaves /Havells /Usha) |
| 98 | Supply and installation of high flow 400 mm diameter swipe floor stand of min hieght 1 meter from the ground mounted 3 PVC blades 3 speed controll fans. Watt – 50-60 Frequency 50Hz. (Make : Crompton greaves /Havells /Usha) |
| 99 | SHEET METAL WORKS :- 0-750 -------0.63 MM (24G) with flangesSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 100 | SHEET METAL WORKS :- 751-1500------0.80 MM (22G) with MS flangesSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 101 | Duct thermal insulation :- 19 mm thickSupplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \"O\") Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 102 | Insulation on chilled water pipe- 19 mm thickSupplying, laying, fixing, testing and commissioning of followingthickness closed cell elastrometric nitrile rubber of class \"O\"applied by suiatable adhesive, as per specifications and asrequired complete in all respect. |
| 103 | Supply of Capacitor application-General purpose.Dielectric characteristic-C0G / NP0.Tolerance- 5%.Capacitence - 40-50 Micro fared.Frequency-50Hz MPSSH.Operating temperature-max 125 degree C.Operating temperature-min 44 degree C.Operating temperature range--40 degree C to +85 degree C |
| 104 | Supply of Aluminium tapes for wrapping on the HVAC pipe lines for avoiding the air leakage (size – 50mmX40 Mtr) |
| 105 | Supply and installation of pressure gauges of dial size 100 mm diameter 10 kg/cm², For the measurement of fluid liquidsthat are non highly viscous, high temp (60 degree celsius), the outer diameter of the threads will be 15 mm |
| 106 | Supply and installation of pressure gauges of dial size100 mm diameter 10 kg/cm², For the measurement of fluid liquidsthat are non highly viscous, high temp (60 degree celsius), the outer diameter of the threads will be 12 mm |
| 107 | Kitchen Hoods section |
| 108 | Servicing of Kitchen hoods with suitable chemicals,brushes etc. The hood was loaded with dirty oil, dust and carbondeposit on the walls of the hoods. The hood is made up ofstainless steel 304 grade. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift, transportation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 109 | Servicing of Scrubbers, pumps, motors. And blowers and entire AHU unit. The scrubber is loaded with dirty oil, dust and carbondeposit on the walls of the AHU unit. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift, transportation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |
| 110 | Servicing of Kitchen hood exhaust ducting with suitable chemicals, brushes etc. The ducting was loaded with dirty oil, dust and carbondeposit on the walls of the hoods. The hood is made up ofstainless steel 304 grade. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift, transportation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. |