Public Administrative Department Local Bodies Closing in 0 days TDR #31759484

Construction Of Health Wellness Center At Dhanirampur In Dhanirampur Ii Gp In Falakata Block Under Alipurduar Zilla Parishad

Issued by Local Bodies · falakata, West Bengal
Tender Value
35.92 Lakhs
Estimated cost
Bid Submission
22 Apr 2022
0 days left
EMD
71851
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
falakata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Health Wellness Center At Dhanirampur In Dhanirampur Ii Gp In Falakata Block Under Alipurduar Zilla Parishad

BOQ

Name of Work: CONSTRUCTION OF HEALTH WELLNESS CENTER AT DHANIRAMPUR IN DHANIRAMPUR II GP IN FALAKATA BLOCK UNDER ALIPURDUAR ZILLA PARISHAD (Two Storied) (Pakur Variety)
Sl. No. Item Description
1ORIGINAL CIVIL WORK Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
2(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000mm. but not requiring shoring.
3Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
4Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)at Plinth lvl (for below flooring)
5Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction.a) Single brick flat soling (thickness 75 mm.)
6(II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. Variety (a) 1:3:6 Poportion
7Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, In ground floor as per relevant IS codes. a) Pakur varietyAt Ground Floor
8At First Floor
9Reinforcement for reinforced concrete work in all sorts of structure i/c. distribution bars, stirrups, binders etc. including supply of rods, straightening and removal of loose rust (if necessary) cutting to requisite length, hooking and binding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(i) Tor steel/Mild Steel II. JSW / JSPL / SHYAM / SRMB / BMASL / ELECTROSTEEL/SSLFor Ground Floor
10For First Floor
11Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(f) 25 mm to 30 mm shuttering without staging in foundation
12a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.At Ground Floor
13ii) In first floor.Column above PL to bottom of FF Slab :
14Brick work with 1st class bricks in cement mortar (1:6)a) In foundation and plinth
1525mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer\"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface Plinth level 125 thick wall (excluding openings)
16125mm thick B/W with 1st class bricks in cement mortar (1:4 )(b) In Superstructure i) In ground floor
17First Floor
18Supplying, fitting & fixing 1st quality Ceramic tiles in wall and floors to match with the existing work and 4 nos. of key stones ( 10 mm ) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor with sand cement mortar (4:1) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement 2.91 kg./M2 & joint filling using white cement slurry @ 0.20 kg./M2i) In ground floor.
19First Floor
20(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.i) In ground floor.
21Frist Floor
22Labour for Chipping of concrete surface before taking up Plastering work.
23Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar(b) 20 mm thick plaster(1) In ground floor.
24(2) In first floor.
25(c) 15mm thick plaster Ground Floor
26(2) In first floor.
27ii) With 1:4 cement motar(c) 10mm thk plaster i) In ground floor.
28ii) With 1:4 cement motar(c) 10mm thk plaster ii) In first floor.
29Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats a) In ground floor:..
30b) In first floor:..
31Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(a) One Coatii) Solvent based interior grade Acrylic Primer
32b) In first floor:..
33Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primera) Normal Acrylic EmulsionTwo coatsi) In ground floor:
34Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primera) Normal Acrylic EmulsionTwo coatsi)ii) In first floor:
35Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).
36M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to i) For trusses spanning up to 12.00 m50mm Dia Pipe (Heavy type)
37Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete.
38Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc.
39M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -chargei) In ground floor.
40M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge ii) In first floor.
41MS or WI Ornamental grill or approved design joints continuously welded with MS or WI flats and bars of window, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Ground Floor(i) Grill weighing above 10kg/m2 and upto 16kg/m2
421st floor (i) Grill weighing above 10kg/m2 and upto 16kg/m2
43Supplying profiles of required section made of Aluminium Alloy Extrusions Conforming to IS: 732-1983 and IS: 1285-1975: Annodized ( with required Film thickness and Specified colour / natural) matt Finished conforming to IS: 1868-1983 for fabrication of composite Door , Sliding & casement windows, Partitions, formed of Basic Sections of any IS embossed / certified make and Brand as per Direction of Engineer-in-Incharge. ( Payment will be made on finished length of the work )(A)10-12 Micron thickness annodizing filmI) In ground floor.i) Natural Whitea) 2-track sliding windowi) Bottom frame
44ii) Top and side frame
45a) Shutter for all track sliding windowi) Bottom & Top member
46ii) Style Side member
47iii) Interlocking member
48h) Louvered windowi) Top, bottom and sidemember
49ii)Louvered Section
50iii) Cleat angle ( Non-annodized)
51k) Movable Door Shutteri) Door frame. (Top & Sides)
52ii) ShutterTop rail
53Bottom rail
54Lock rail
55Door vertical
56Glazing Clip
57g) Fixed glazingi) Top, bottom and side member.
58iii)Glazing clip.
591st Floor i) Natural Whitea) 2-track sliding windowi) Bottom frame
60ii) Top and side frame
61a) Shutter for all track sliding windowi) Bottom & Top member
62ii) Style Side member
63iii) Interlocking member
64h) Louvered windowi) Top, bottom and sidemember
65ii)Louvered Section
66iii) Cleat angle ( Non-annodized)
67k) Movable Door Shutter i) Door frame. (Top & Sides)
68ii) ShutterTop rail
69Bottom rail
70Lock rail
71Door vertical
72Glazing Clip
73g) Fixed glazingi) Top, bottom and side member.
74iii)Glazing clip.
75Supplying EPDM gusket of approved make and brand as per direction of engineer- in- chargei)For sliding windowsa) \" T\" shaped EPDM gasket for frames.
76iii) Weather gasket / wool pile for door vertical
771st Floori)For sliding windowsa) \" T\" shaped EPDM gasket for frames.
78iii) Weather gasket / wool pile for door vertical
79Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(vii) 100x75x4.00 mm
80Supplying PVC rollers for sliding windows as per direction of Engineer in charge.Ground floor window
81Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. a) In ground floor.(i) 2 Track sliding window
82(v)Louvered window
83b) In first floor..(i) 2 Track sliding window
84(v)Louvered window
85(B) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with asketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in chargei) In ground floor.
861st Floor
87Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.vi) 6mm thick coloured / tinted / smoke glass.Ground Floor(d) 3.0 mm thick (5.10 Kg/Sq.m)
88ii) In first floor.
89Supplying, fitting and fixing in position fibre glass panes of approved quality with resin, nail, clip etc. as per IS:12866-1989. (In all floors for internal wall & upto 6 m height for external wall)
90Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod) (iv) 125 mm grip x 10 mm dia rod.For Door
91Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iv) 150mm long x 10mm dia. bolt.
92Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(vii) 225mm long x 10mm dia. Bolt
93i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting(b) 250mm long.
94Collapsible Gate with (40x40x6mm) Tee as top & bottom Guide rail, 20x10x2mm Vartical channel 100 mm as per in fully stretched portion 20x5 MS flats as collapsible lovacings property rivetted & washered including 38mm steel rollers including locking arrangement , fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in wall, floor etc. and making good damages complete.
95Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. G.F
96Painting with best quality synthetic enamel paints of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. the surface, if necessary. (b) On steel or other metal surfacewith super gloss ( hi gloss ) (i) Two coat ( With any shade Except White ) G.F
97Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii)110 mm. Dia.
98a) Plain Tee(ii)110 mm. Dia.
99b) Plain Y (ii)110 mm. Dia
100c) Bend 87.5 degree(ii)110 mm. Dia.
101d) Shoe(ii)110 mm. Dia.
102Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colouri) In ground floor.
103Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mmii) In first floor.
10418 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]i) In ground floor.
10518 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry withii) In first floor.
106SANITARY & PLUMBING WORKS Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(b) For Concealed Work(ii) CPVC Pipes Class-2,SDR-13.5(A) 20mm
107(B) 25 MM
108(a) For Exposed Work(i) CPVC Pipes Class-I,SDR-1132mm
109(a) For Exposed Work(i) CPVC Pipes Class-I,SDR-1140mm
110Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 A) (i) Single Socketed 3 Meter Length 75mm (Bathroom & Kitchen drain line)
111Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 A) (i) Single Socketed 3 Meter Length 110mm (Soil Line)
112(B) Fittings(iii) Door Tee (b) 110 mm
113ix) Bend 45º (b) 110mm
114xi) Door Bend (T.S.) (b) 110 mm
115xIvi) Door Cap (b) 110 mm
116xv) Vent Cowl (b) 110mm
117xxii) 125/110 S Trap with W.C. Ring75 mm
118xxxiv) Multi Floor Trap without Top tile & Strainer75 mm
119Supplying, fitting and fixing water closetsSupplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.(b) With \"S\" trap (with vent)
120Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
121Supplying, fitting and fixing white vitreous china best quality approved make Wash basin with C.I brackets on 75 mm x 75 mm wooden blocks, C.P. waste fittings of 32 mm dia, one approved quality brass C.P. pillar cock of 15 mm dia, C.P. chain with rubber plug of 30 mm dia, approved quality P.V.C waste pipe with C.P. nut 32 mm dia, 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paints.(ii) 550 mm x 400 mm
122Supplying, fitting and fixing pedestal of approved make for wash basin (white)
123Supplying, fitting and fixing stainless steel sink complete with wastfittings and two coats of painting of C.I. brackets.(a) Sink only (ii) 630 mm X 550 mm X 180 mm
124(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No.511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
125Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) FOR SINK
126(ii) Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
127(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
128e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand).
129Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass(ii)25 mm dia. and 600 mm long
130Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colourframe size 550 mm X 400 mm
131Supplying, fitting and fixing porcelain soap tray of approved make.(i) Recessed soap tray of size 150 mm X 150 mm
132Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe (Cistern)
133Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iii) 600 mm long
134Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long
135(a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
136(a) (iii) Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
137(f) Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook (Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
138Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1000 litre capacity
139Labour for hoisting plastic water storage tank.(i)Upto 1500 litre capacity.1st Floor
140Labour for punching hole in plastic water storage tank upto 50 mm dia.
141Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping (i) For 20 users A) With Pakur variety. (JSW / JSPL / SHYAM / SRMB / BMASL / ELECTROSTEEL/SSL)
142Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.ii) With Bazree (N.B Varity) (JSW/JSP/SHYAM/BMASL/ELECTROSTEEL/SSL)
143Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia A) With Pakur variety. (JSW / JSPL / SHYAM / SRMB / BMASL / ELECTROSTEEL/SSL)
144Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A)Above ground(ii) 110 mm dia. pipe
145(i) 75 mm dia pipe
146Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm.
147.Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm
148. (Z) Compact Compact Ball Valve with SS Handle For CPVC/ UPVC Fittings.(As per ASTM D 2467, Schedule 80). 25 mm dia.
14940mm dia.
150Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007. (I) Tank connecting nipple. 40mm dia.
151RIG BORE TUBE WELL SUB MERSIBLE PUMP Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre).(i) First 50 metre
152(ii)Next 50 metre
153Supplying brass-strainer with brass socket of approved make. (Heavy type)
154Supplying, fitting and fixing heavy type bell mouth reducing socket. (iii)100 mm X 150 mm
155Supplying M.S. male /female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per directionof Engineer - in Charge (i) 100 mm
156Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
157Providing 200 mm centre guide. i) With Clamp
158(A) Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of of TATA make (heavy quality) as per standard specification, 5 mm thick. (i)150 mm dia. (internal)
159Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required.
160Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
161Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
162Supplying, fitting and fixing G.I. cap at top(ii) 150mm
16369.00.Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part - I). with allnecessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder batslamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work(i) 32mm dia.
164ii). 15 mm dia
165Supply& fixing & installation on CC muffing of feeder piller (2\"x2.5\"x1\") box febricated by 14SWG MS sheet with angle for main switch starter as stated below with hinged door and locking arrangment as per direction of EIC a) 230/250V,15A,SPN SFU with re-wireable fuse(L&T)b) 230V,1.5HP, DOL Starter with A&V meter (L&T) c) Dener board-1set.
166supply& saying 1.1KV rgade 2x10 sqmm PVC/A AI cable in UG treanch as to GS with 1x6SWG GI wire.
167Supply & fixing of compressive type cable gland as to GS for 2x10 PVC/A cable.
168Finishing the cable end by crimping method as to GS.
169Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Lomg and 1x4 SWG GI (Hot Dip) wire (4 Mts. Lomh), 13 mm dia x 80 mm long GI bolts double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Nts. Long) to be filled with betumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe.
170Supply, Installation, tesing & lowering of 1.5 HP water filled submersible pump motor set complete having suitable discharge as per yeld of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC ber chart (Crompon make Pump) and necessary control panel and starter as per manufacturar specifications.( Rate arrived after quatation which is enclosed)
171Add GST @ 12%
172Add Cess @ 1%

AI Tender Summary

OUR REF NO 31759484
AUTHORITY Local Bodies
TENDER VALUE 35.92 Lakhs
LAST DATE 22-04-2022
Authority
Authority Name Zilla Parishad
Work Description Construction Of Health Wellness Center At Dhanirampur In Dhanirampur Ii Gp In Falakata Block Under Alipurduar Zilla Parishad
Basic Detail
Tender No WBZP/03-EE/APD/2022-23
Bidding Type Tender
Location
City falakata
State West Bengal
Key Dates
Publish Date 07 Apr 2022
Submission Date 22 Apr 2022
Open Date 25 Apr 2022
Finance
Tender Value 35.92 Lakhs
Tender Fee Ref. Documents
EMD 71851
Exemption Not Available
Document List
1ac6b8af-107f-4672-83b9-87e73d80f6c2.html
BOQ_732034.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 22, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 25, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1ac6b8af-107f-4672-83b9-87e73d80f6c2.html

xls

BOQ_732034.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders