Environment and Forests Government Departments Closing in 0 days TDR #31755973

Repair And Renovation Of Mpcb Staff Quarters At Nerul And Belapur Navi Mumbai

Issued by Government Departments · belapur, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Apr 2022
0 days left
EMD
4.45 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
belapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Renovation Of Mpcb Staff Quarters At Nerul And Belapur Navi Mumbai

BOQ

Name of Work: Repair & Renovation of MPCB Staff Quarters at Nerul & Belapur, Navi Mumbai.
Sl. No. Item Description
1Demolition Works
2Removing tiled flooring in all types of wall tiling or flooring i.e. Shahabad, Kotah, Cement, vitrified,Marble mosaic, Glazed, Ceramic tiles etc. including stacking and disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge.
3Removing gypsum/lime or cement plaster including disposing off the spoils as directed with all lifts and leads.
4Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge.
5Demolishing waterproofing/brick bat by manually/ by mechanical means including disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge.
6Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking and disposal of unserviceable material with all lead and lifts as per direction of Engineer-in-charge. :
7Dismantling old sanitary fixures of all types i.e. W.C., urinals, wash basin etc. including its pipes and stacking of serviceable material and disposal of unserviceable material with all lead and lifts.
8Removing old electrical fixtures of all types i.e. lights, fans, detectors, exhaust fan etc. including its wiring and stacking of serviceable material and disposal of unserviceable material with all lead and lifts.
9Removing all types of ceiling i.e. Gypsum, perforated ceiling tile, calcium silicate, mineral fibre etc. including stacking and disposal of unserviceable material with all lead and lifts.
10core cutting in existing RCC wall or slab upto100 mm dia and upto 200 mm deep. The rate shall include making good of the core with airtight micro concreting and water proofing after completing the work. The work should be tested for leak proof to the satisfaction of the EIC/Architect
11core cutting in existing RCC wall or slab upto200 mm dia and upto 300 mm deep. The rate shall include making good of the core with airtight micro concreting and water proofing after completing the work. The work should be tested for leak proof to the satisfaction of the EIC/Architect
12Civil Works includes Mansonry, Flooring, waterproofing,RCC repairs etc.
13Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of any size in extra fine jointing mortar of fixo block of UltraTech or equivalent in superstucture including, striking joints, racking out joints watering and scaffolding etc.complete
14Providing internal plaster in cement mortar in 1:3 with neeru finishing to concrete or masonry surface in all position including scaffolding and curing complete. 12 mm. thick Plaster. (Wall)
15External plaster with 20 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 8mm thick cement plaster 1:3 (1 cement : 3 coarse sand) with neeru finsh. Note: the rate shall include scaffolding.
16Providing and fixing chicken mesh made out of 22 / 24 gauge wire with openings of 25 mm x 25mm or less as approved over junctions of RCC brickwork or any other similar materials, nailing the chicken mesh with wire nails at 200-250 mm c/c prior to plastering, all labour and materials complete.
17Toilet & Wet Areas Waterproofing (viz-steam room, shower, kitchen etc) - Providing and Applying waterproofing and filling for Toilet & other wet areas in following parts as per the specifications listed below and as approved by the engineer-in-charge with a guarantee of 10 years : TREATMENT TO FLOOR AND WALLS:The waterproofing material using M/s. Hitchins-singapore Formdex Uni / Vandex BB 75 E / Blue Hy Seal a cementitious, two-component, polymer-modified, heavy duty slurry waterproofing membrane. Formdex Uni / Vandex BB 75 E / Blue Hy Seal can be applied to both horizontal and vertical masonry surfaces with excellent of 1.3N/mm2 adhesion to substrate against active or passive water pressure.It has high tensile strength of 1.6 N/mm2, elongation of 127% & crack bridging capacity of 2.0mm & is resistance to water pressure @ 6.0 Kg/cm2.The FIRST PART: Cleaning the surface for treatment by removing dust, dirt, surface laitances, loose materials etc by wire brushing & water jetting including making covings in CM1:4 added with Aqua Bond 150 @ 250ml/ bag of cement, at junction of floor slab & vertical wall prior to the waterproofing treatment. Providing and carrying out FORMDEX UNI / Vandex BB 75 E / BLUE HY SEALtwo component polymer modified cementitious water proofing treatment on to slab and walls upto 1.0m height in genaral & 2.0m height in shower areas on damp surface @ 1.0kg/sqm/coat in two coats brush applied and reinforcing with chopped strand fiber glass mat of 225 gsmat upturns and around all detailing as per the manufacturers.
18The Second Part PROTECTIVE PLASTER TO FLOOR & WALL:consisting of providing and laying avg. 10-12 mm thick, CM 1:4 screed / plaster to floor & walls admixed with Integral Waterproofing Compound of approved makes as per manufacturer\"s specifications
19The Third Part consisting of Providing and filling110mm thick Block bat coba in the sunken portion in CM 1:4 including approved make of waterproofing admixture as per the manufacturer\"sspecification, finished on the top with screed 30mm thick in CM 1:4, kept rough to receive subsequent tile, curing and testing for water tightness for 7 days etc. complete.
20Extra Thickness if required over 110 mm providing Block bat coba light in the sunken portion in CM 1:4 including approved make of waterproofing admixture as per the manufacturer\"sspecification, finished on the top with screed in CM 1:4, kept rough to receive subsequent tile, curing and testing for water tightness for 7 days etc. complete.
21Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS.15622-2006 (GroupBla)of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete
22Providing and laying vitrified mirror/glossy finish tiles having size 590mm to 605mm x 590mm to 605mm of 8 to 10mm thickness and confirming to IS.15622-2006 (groupBla)of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
23Providing and laying vitrified mirror/glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (groupBla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
24Granite platform top.. Providing and constructing 600 mm Wide Granite Pantry/Toilet Platform by using 18 mm thick (+/- 2 mm tolerance ) mirror polished granite stone at top to be laid on 25mm thick cuddappah stone base, set in cement mortar 1:4, all exposed edges to be rounded and polished. Also providing vertical facia of granite as shown on drawing. Rate to include making opening for wash basin and pillar tap with all exposed edges polished . All joints shall be made water tight in perfect line, level & slope as desired including curing, polishing & cleaning all joints and floating in coloured cement mortar. Granite shall be of approved colour & shall be as per Architects approved lot. (Only plan area will be measured. Wastage due to dimensional difference, pattern, cutting sizes available will be to the contractors account). Rate to include all holes & openings required for fixtures and fittings. All as per drawing and instructions from Engineer in charge. SS Sink / Sink to be Paid Separately .
25Providing and fixing in position & in stepped manner one side mirror polished machine cut Granite slab Jamblining for Door / Window frames / ledge wall top of width upto 300mm of 18mm thickness (+/- 2 mm tolerance) in cement mortar bedding (1:4) of required thickness. Joints, edges to be floated and finished on neat cement of the same colour as the slab. After setting, the slabs (if read) are to be machine polished at site to obtain perfect finish. All exposed edges to be rounded & polished. The rate to include all necessary chipping of brickwork / concrete so that the slab is 12mm projects from plaster / POP surface with rounding of edges, polishing etc. complete as shown on drawing & as per directions of Engineer In charge. Note: No payment will be made for overlapped portion of the jamblining.
26Providing & Applying Dura Clean-WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/grinding the surface by grinder machine, wirebrush, removing existing corrosion from the metal surface also removing loose particles (using other mechanical/manual means) and apply on prepared surface of DuraGuard-ascorrosion preventive coat on prepared TMT bars, steelstructure, metalsurface etc. to protect it from corrosion etc. as per manufacturer\"s specification (using other manual/ mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge.
27Providing and applying 30 mm thick self curing Ceremic Polymer Microconcrete of approved make having Compressive strength above M30, nonshrink, impermeable, filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface, including honeycomb area (usingmanual/mechanical means). Mixing mortar of NicosilC80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying andf/ inishing by manual trawelling, curing after curing initial setting time etc,as per manufacturers specification etc. complete as per specification and as directed by engineer-incharge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs.500/-stamppaper. (Bondcoat mentioned below is to be done before coating)
28Providing and fixing in position reinforcement of all dia for RCC piles, pile caps, footings, foundations, slabs, columns, beams, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required at all locations and height all labour and materials testing etc.complete.
29Providing and fixing in position Vitrified material Paver tile (Pavit) set to pattern as per drawing on wall/flooring including average 30mm thick cement mortar 1:4 bedding floated with neat cement slurry, filling the joints with matching color pigment mixed with cement laid to perfect line and level & pattern. No extra payment will be made towards wastage due to material pattern & design. payment shall be made on finished floor/wall area only. Rate shall be applicable to all levels & heights.
30Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (naturalsand/crushed sand VSIgrade finely washed etc.) , compacting and proper embedding /laying of interlocking paver blocks into the fine aggregate (naturalsand/ crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSIgrade finely washed etc.) and complete as per manufacturers specifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern.
31Providing and fixing double scaffolding system (cuplocktype) on the exterior side of building / structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S.tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamp sand staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:-(1)The elevational area of the scaffolding shall be measured for payment purpose. (2)The payment will be made once only for execution of all items for such works.
32Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.
33Plumbing Works
34Providing & fixing in position heavy duty CP brass plug cock / screw cock / stop cock conforming to IS:781-1984 including necessary socket/union nut etc. complete for fixing cocks, sun and safeda must be used to make joint perfectly watertight.
35Providing & fixing in position centrifugally cast (spun) C.I. soil / vent waste pipe conforming to IS: 3989-1984 including all requisite specials such as bends, tees, single junctions, double junction, slotted vent offsets on wall including making holes in masonry and / or concrete remaking the same with all requisite fittings, clips including laying & jointing etc complete.a) 75mm
36Providing & fixing in position centrifugally cast (spun) C.I. soil / vent waste pipe conforming to IS: 3989-1984 including all requisite specials such as bends, tees, single junctions, double junction, slotted vent offsets on wall including making holes in masonry and / or concrete remaking the same with all requisite fittings, clips including laying & jointing etc complete.a) 100mm
37Providing & fixing in position centrifugally cast (spun) C.I. soil / vent waste pipe conforming to IS: 3989-1984 including all requisite specials such as bends, tees, single junctions, double junction, slotted vent offsets on wall including making holes in masonry and / or concrete remaking the same with all requisite fittings, clips including laying & jointing etc complete.a) 150mm
38Providing and fixing chlorinated Poly Vinyl Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. a) 25mm
39Providing and fixing chlorinated Poly Vinyl Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. a) 15mm
40Providing and fixing chlorinated Poly Vinyl Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in Charge. a) 20mm
41Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)
42Providing and fixing in position UPVC Nahani Trap of 110mm including SS grating, fixing in cement concrete M-15 etc. complete.
43Providing and fixing 2 way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (Jaquar- FON-40041)
44Providing and fixing Hand shower (health faucet) with 8mm dia. 1.2m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (Jaquar- ALD-577)
45Providing and fixing Table top white wash basin with bottle trap earthenware Wash Hand Basin of 63x45 cm size including coldwater pillertaps, brackets, rubber plugs and brass chain, stoptap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete.
46Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank and flush valve with floor mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
47Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
48Providing and fixing Sink Mixer With Regular Swinging Spout (Wall Mounted Model) With Connecting Legs & Wall Flanges
49Gate Valves - 25mm
50Gate Valves - 32mm
51Providing and fixing Stainless steel towel rod with 20 mm diameter pipe in bathrooms and wherever necessary manufactured as per best engineering practice or as per I.S. wherever applicable with necessary materials and labour cost etc. complete. Upto 1200mm length.
52Painting work
53Providing and applying plaster/wall punning with plaster of paris (with plaster of paris material of Ambuja/MorChap or equivalent make) in 10 to 13 millimeter thickness to previously plastered surface/or on newly bricksurface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc.complete.
54Providing and applying plastic emulsion paint conforming to IS:5411-1991 part I of superior quality of approved make, colour and shade to the old & new surfaces in two coats over primers, including scaffolding, preparing the surfaces to receive the paint and applying putty etc. complete.
55Providing and applying three coats white/colour wash on old and new plastered or masonry surfaces or concrete surface and asbestos cement sheets conforming to IS:6278-1991 including scaffolding and preparing the surface by brushing and brooming etc. complete.
56Providing and applying two coats of Exterior Acrylic paint of approved make and of approved colour to the plastered surfaces including cleaning, prepairing the plaster surface ,applying primer coat as per manufacturer\"s specifications, , scaffolding if necessary, etc.complete.Providing and applying two coats of Exterior Acrylic paint of approved make and of approved colour to the plastered surfaces including cleaning, prepairing the plaster surface ,applying primer coat as per manufacturer\"s specifications, , scaffolding if necessary, etc.complete.
57Doors & Windows Works
58Providing and fixing best quality superior Indian teak wood frame for doors, windows and ventilators including all moulding, rebating, jointing, hold fasts of MS flats of minimum size 20 x 3 mm, having length of 225 mm for doors & 150 mm for windows and finishing with 3 coats of French polish or one coat of primer and synthetic enamel paint in two coats as directed etc. complete.
59Providing & fixing 35mm thk. Phenol bonded Flush door finish with 1.5mm thk. Laminate on both sides as per approved pattern. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall include all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, latches, wooden teakwood louvers etc. as required.
60Providing and fixing anodised aluminium louvered windows & ventilators with mosquito net, conforming to IS:1948- 1991& 1949-1991 with windows frame made of standard Z section with minimum 4 mm. thick (as specified by the manufacturer) frosted/white sheet glass as specified by department, including aluminum stays, specially designed louvered hinges (design to be got approved from the Dept.) locking arrangement and other necessary fixtures and fastenings, glass fixing clips as approved by the Department etc. complete including finishing, cleaning, polishing the aluminium frame with petrol and/or other agents as specified by the manufacturer etc. complete. a) Aluminum section used
61Providing and fixing anodised aluminium louvered windows & ventilators with mosquito net, conforming to IS:1948- 1991& 1949-1991 with windows frame made of standard Z section with minimum 4 mm. thick (as specified by the manufacturer) frosted/white sheet glass as specified by department, including aluminum stays, specially designed louvered hinges (design to be got approved from the Dept.) locking arrangement and other necessary fixtures and fastenings, glass fixing clips as approved by the Department etc. complete including finishing, cleaning, polishing the aluminium frame with petrol and/or other agents as specified by the manufacturer etc. complete. b) 4 mm frosted glass used.
62Providing and fixing anodized (anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodising must be scaleted by keeping the anodized section in boiling de-anodized water for a period of one hour) aluminium sliding type windows conforming to IS:1948, 1961 (all shutters sliding) with hollow bottom section & standard two / three / four track frame section all round (top, bottom and sides) with shutter frame made up of standard handle section standard interlocking section and standard top and bottom section with glass with nylon guides, gliders glass fixing PVC weather strips, PVC weep holes etc complete with approved type of locking arrangement, handles and other fixtures including fixing, cleaning polishing the aluminium section with petrol and / or other agents as specified by the manufacturers etc. complete. (The rate shall be inclusive of silicon Sealant / Neoprene gasket). a) 4 mm thick tinted
63Providing and fixing anodized (anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodising must be scaleted by keeping the anodized section in boiling de-anodized water for a period of one hour) aluminium sliding type windows conforming to IS:1948, 1961 (all shutters sliding) with hollow bottom section & standard two / three / four track frame section all round (top, bottom and sides) with shutter frame made up of standard handle section standard interlocking section and standard top and bottom section with glass with nylon guides, gliders glass fixing PVC weather strips, PVC weep holes etc complete with approved type of locking arrangement, handles and other fixtures including fixing, cleaning polishing the aluminium section with petrol and / or other agents as specified by the manufacturers etc. complete. (The rate shall be inclusive of silicon Sealant / Neoprene gasket). a) clear glass
64False Ceiling Works
65Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceilinsection and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm or both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting.
66Electrical Works.
67Supplying and erecting UPVC reinforced flexible conduit 50 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
68Supplying and erecting UPVC reinforced flexible conduit 25 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
69Point wiring in for light/fan/bell in 20 mm Metal/PVC conduit as required with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
70Secondary point wiring for additional light/ bell point, concealed type in min 20 mm metal/PVC conduit as required with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
71Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/ BW
72Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/ BW
73Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 modules duly erected.
74Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 modules complete duly connected
75Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected.
76Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
77Supplying and erecting ISI mark modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
78Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
79Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
80Supplying & erecting LED 20W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
81Supplying and erecting corridor/passage light fitting (2 feet) including 9W LED lamp, comprises of extruded channel in plastic silver grey colour & with same plastic end cap on provided PVC block / wooden board.
82Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
83Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
84Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF
85Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF
86Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
87Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
88Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
89Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB
90Supplying, erecting & terminating XLPE armoured cable 3 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
91Solar Panel System Works for 20 KW.
92Providing, Supplying, Installing Solar roof of Polycrystalline 325 wpIp67/ IEC61215-61730 Class A Fire Rated Modules with aluminium T profile, PU SealeantSausages,Self Drilling Hex Head Screw etc complete as per direction of Engineer in charge.
93Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
94Providing, supplying Solar Inverter of 20 KV 3 Ph, 440 V String inverter as per direction of Engineer in charge.
95Balance of System- (BOS) - a) 1C x 4sq.mm, Double Insulated Copper cable with all required accessories like MC & FMC , Cable ties, connectors etcb) DCJB\"s or DCDB - JB\"s 2 Nos( 10IN & 10OUT-50KW)c) AC Cable AL Armored - 3.5C x 50Sq.mm , AL Ar. Cable- 50KW ( Inverter to Existing) & 3.5C x 25 Sq.mm , AL Ar. Cable- 20KW ( Inverter to Existing)d) AC Distribution Panel Board - IP-54 rated enclosures with all switchgears, 100A ,4P MCCB- 50Kw and 63 A,4P MCB-40Kwpe) Cable Tray - Cable tray of Suitable sizes and type with all acessories and required supports.f) Earthing - 17.2 mm Thick 3 meters Long Cu Bonded with Carbon Compound, Conventional Model- Type IV (1 meter Copper rod with Sikes and 3 Meters height GI Pipe), Each set Per Inverter, Fixing the Solar Panel on Roof GridFixing the Solar Panel on Roof Grid.g) Civil Works & Water proofing works which required to complete the works.
96Installation, Testing, Commissioning & Miscllaneous Safety Equipmentsa) Approvals & Liasioning - Net Meters & CEIG (Initial and Final Approval)b) Installation & Commissioning - Module Interconnection, Connections of ACDB, Fire Extinguishers, Sand buckets, Danger Boards, Radium Sticker for marking, Rubber mat for LT, HT panel, inverter., Foam type 9 Ltr , Portable type, First aid box, Safety instruction charts, Transportation

AI Tender Summary

OUR REF NO 31755973
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-04-2022
Authority
Authority Name Maharashtra Pollution Control Borad
Work Description Repair And Renovation Of Mpcb Staff Quarters At Nerul And Belapur Navi Mumbai
Basic Detail
Tender No MPCB/EE/01/2022-23
Bidding Type Tender
Location
City belapur
State Maharashtra
Key Dates
Publish Date 07 Apr 2022
Submission Date 21 Apr 2022
Open Date 22 Apr 2022
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 4.45 Lakhs
Exemption Not Available
Document List
238b7f35-0dc5-41cb-81b7-069e20b023f6.html
BOQ_1355564.xls
RFPNEW.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 21, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 22, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

238b7f35-0dc5-41cb-81b7-069e20b023f6.html

xls

BOQ_1355564.xls

pdf

RFPNEW.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender