Construction Of Samudayik Bhawan, Kitchen, Sitting Bench, Hexagon Shade, Paver Block, Electrification Work And Renovation Of Well, Chabutras And Extension Of Boundary Wall With Concertina Wire At Lilori Mandir Gangapur, Daludih. Dist.-Dhanbad Construction
Tender Overview
Project Description
Construction Of Samudayik Bhawan, Kitchen, Sitting Bench, Hexagon Shade, Paver Block, Electrification Work And Renovation Of Well, Chabutras And Extension Of Boundary Wall With Concertina Wire At Lilori Mandir Gangapur, Daludih. Dist.-Dhanbad Construction Of Samudayik Bhawan, Kitchen, Sitting Bench, Hexagon Shade, Paver Block, Electrification Work And Renovation Of Well, Chabutras And Extension Of Boundary Wall With Concertina Wire At Lilori Mandir Gangapur, Daludih. Dist.-Dhanbad
BOQ
| Sl. No. | Item Description |
| 1 | E/W in excavation in foundation trenches in ordinary and hard soil ( vide classification of soil Item – A and B ) and disposal of excavated earth clearance to distebce up to 50 M including all lifts with leveling, removing the trenches removing roots of trees shrubs all complete as per specification and direction of E/I. ( 5.1.1+5.1.2) |
| 2 | E/W in excavation in foundation trenches in all kinds of soil ( vide classification of soil Item – A) and disposal of excavated earth as obtined to a distance up to 50 M including all lifts, levelling , ramming the foundation trenches, removing roots of trees, shurbsall complete as per approved design, building specification and direction of E/I. ( 5.1.1 ) |
| 3 | Providing Coarse Clean sand in filling in foundation trenches or in plinth including removing and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per specification and direction of E/I.(Mode of measurement compacted volume). (5.1.10) |
| 4 | Providing designation 75- B, Brick Flat Soling joints filled with local sand including cost of watering, taxes and royalty all complete as per building specification and direction of E/I (5.6.3) |
| 5 | Providing and laying in position cement concrete (1:2:4) of specified grade exccluding the cost of centering and shuttering - all work upto plinth level(1:2:4)(1 cement 2 coarse sand zone-iii ): 4 ggraded stone aggregate 20 mm nominal size) (5.3.1.2) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering , shuttering,finishing and reinforcement -all work upto plinth level.1:1.5:3 (1 cement 1.5 coarse sand zone-iii ): 3 graded stone aggregate 20 mm nominal size) (Stone aggregate 20 mm nominal size)(5.3.9.1) |
| 7 | Reinforced cement concrete work in walls (any thickness),including attached pillasters , buttresses , plinth and string coarses , fillets , columns ,pillars ,abutments ,posts and struts etc above plinth level upto floor five level,excluding cost of centering ,shuttering finishing and reinforcement 1:1.5:3 (1 cement 1.5 coarse sand zone-iii ): 3 graded stone aggregate 20 mm nominal size) (Stone aggregate 20 mm nominal size) (5.3.10) |
| 8 | Providing designation 75- B, Brick work in C.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick motor joint, cost of screening materials rakingout joints 15 mm depth, curring, taxes and royalty all complete as per building specification and direction of E/I (5.2.6) |
| 9 | Reinforced cement concrete work in beam\"s suspended floor\"s roof\"s having slop upto 15\"\" landing, balconies, shelves chajja, lintels & bands,plain window sills, stair cases and spiral stair cases above plinth level upto floor five level ,excludingthe cost ofcentering ,shuttering finishing and reinforcement, with1:1.5:3 (1 cement 1.5 coarse sand zone-iii ): 3 graded stone aggregate 20 mm nominal size) (Stone aggregate 20 mm nominal size) (5.3.11) |
| 10 | Providing 50 mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cico or any other approved water proofing compound and placing in position, striking, curring taxes and royalty all complete as per building specification and direction of E/I (5.3.5) |
| 11 | Providing designation 75- B, Brick work in C.M (1:6) in Super structure and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick motor joint, cost of screening materials rakingout joints 15 mm depth, curring, taxes and royalty all complete as per building specification and direction of E/I (5.2.14) |
| 12 | Providing 19 mm thick water proof cement plaster (1:3) withclean coarse sand of F.M. 1.5 with 5% cisco or any other approved water proofing compund including screening curring, with all leads and lifts of water, scaffoldingtaxes and royalty all complete Job as per buildingSpecification and direction of E/I. (5.7.15) |
| 13 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water scafolding taxes and royaltyall complete as per building specition and direction of E/I(5.7.6) |
| 14 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specition and direction of E/I(5.7.3) |
| 15 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead 50 M and lift of 1.5 M all complete as building specification and direction of E/I (mode of measurement compacted volume) (5.1.7) |
| 16 | Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water scaffolding and 1.5 mm cement punning including curing carriage of water with all leads and lifts taxes and royalty all complete as per building specition and direction of E/I(5.7.1 + 5.7.11) |
| 17 | providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips with two layersbottom layer 19 mm thick (2:2:4)with 12 mm to 6 mm size graded stone chips and top layer 6 mm thick (1:2) with 6 mm down stone chips in patents including cost of curring, finishing the sudace smooth by rubbing with carborandum stone taxes and royalty with all complete as per building specification and direction of E/I (5.6.7) |
| 18 | Providing Tor Steel reinforcement of following dia bars as per approved design and drawing excluding carriage of bars to work side, cutting, bending and binding with annealed wire with cost of wire, removel of rust placing the rods in position all complete as per building specification and direction of E/I(5.5.4 & 5.5.5)(a) 8 mm dia Rods |
| 19 | (b) 10 mm diaRods |
| 20 | (c) 12 mm dia Rod |
| 21 | Providing and supplying white cement based putty of average thickness 1.00 mm etc. as required(D.S.R.13.80) |
| 22 | Providing two coat oil bond distemper of approved shade and make over a coat of cement primer over new surface - do - do - E/I (5.8.15) |
| 23 | Supplying, fitting and fixing M.S. Gril made of 20 x 6 cmm M.S. rail as per approved design and drawing, properly febricated with joints continuous fillt welded and finished smooth, carriage of grill to work site hoisting as perbuilding specition and direction of E/I(5.5.12) |
| 24 | Supplying fiting and fixing 20 guage G.C.I. sheet gate filed on M.S. angle frame of size 60 x 60 x 60 mm including cost of febrication providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required sixze applying a priming red lead paint over steel work taxes all complete as per diawing specification and direction E/I (5.5.29) |
| 25 | Providing two coats ofpainting with ready mixed paintof approved shade and make over steel surface including cleaning the surface thoroughly scaffolding and taxes all complete as perbuilding specition and direction of E/I(5.8.43) |
| 26 | Finishing wall with premium Acrylic smooth exterior paints with silicon additives of required shade :New work(Two or more coats applied @1.43 ltr/10 sqm over and including priming coat of exteror primer [email protected] kg/10 sqm)(D.S.R.13.47.1) |
| 27 | Centering & Shuttering including struting, propping etc. and removal of form for (i)foundation ,footings,bases of columns ,etc for mass concrete (5.3.17.1) |
| 28 | (ii) Lintel ,beam,plinth beam,girder,bressumers& cantilevers: (5.3.17.5) |
| 29 | (iii) weather shed,chajja,cordels etc including edges(5.3.17.19) |
| 30 | (iv) Suspended floors,roofs,landings,balconies and access platform : (5.3.17.3) |
| 31 | (v)Eges of slabs & breaks in floors & walls(5.3.17.16) |
| 32 | (v)Columns,pillars,piers,abutments,post and struts (5.3.17.6) |
| 33 | Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curring with all lead and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.14) |
| 34 | Providing 50 mm thick cement concrete flooring (1:2:4)with 20 mm to 6 mm size graded stone chipsfinished with flooring coat of neat cement in panelsall complete as per drawing spefification and direction of E/I. (5.6.9) |
| 35 | Supplying, fiting and fixing fan hook of 16 mm dia MS bar 1 m long bent to require size and sape, placed in position and fluid in the R.C.C. Slab Beem at the time of casting all complete as per building specification and direction of E/I.(5.5.13) |
| 36 | Providing two coat oil bond distemper of approved shade and make over a coat of cement primer over new surface including repairing plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I(5.8.18) |
| 37 | Providing & laying flamed finish granite stone flooring in required design and pattern linear as well curvillinear portion of the building all complete as per architectural drawing 18 mm hole stone slab over 20M (av) thickness base and direction of E/I. (5.6.22) |
| 38 | Providing Rough cost plaster in 2 layers the bottoms layer being 12 mm thick in cement mortar (1:3) and top layer finished with gravel, pebbles or crushed stone as per specified cement mortar (1:3) all complete as per building specification and direction of E/I(5.7.17) |
| 39 | Making 6 x 6mm grooves in plasters surface over walls tritely horizontalor vertical as per specification and direction of E/I. (5.7.21) |
| 40 | Providing and laying vitrified floor tiles in different size (thickness to be specified by the manufacturer) with water absorption less then 0.08%and conforming to IS:15622 of approved make ,in all colours and shades,laid on 20 mmthick cement mortar1:4(1 cement :4 coarse sand),jointing with grey cement [email protected] kg/sqm including grouting the joint with white cement and matching pigments etc.,complete -Sizeof tiles 600 x 600 mm(D.S.R. 11.41.2) |
| 41 | Providing and laying 6 mm thick white glazed tiles in walls over 12 mm ,cement mortar(1:3) and jointed with grey cement slurryflush pointed with white cement including rubbing ,polishing and cost of curing taxes and royalty all complete as per building and specification and direction of E/I With \"A\" grade white 15 x 15 cm Tiles(5.6.23.1) |
| 42 | Providing & applying white cement based putty of average thickness 1 mm ,of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete . (D.S.R.13.80) |
| 43 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction , of approved size , design& shape , laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand ,filling the joints with line sand etc. all complete as per the direction of engineer- in-charge.(D.S.R.16.68) |
| 44 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm depth watering and disposal of unserviceable materials with all leadsall complete as per building specition and direction of E/I(5.10.7) |
| 45 | Providing 12 mm Cement Plaster (1:4) with clean coarse sand of F.M 1.5 including screening,curing with all leads and lifts of water , scaffolding taxes and royalty all complete as per buildingspecification and direction of E/I (5.7.2) |
| 46 | Providing Ordinary labour enged for dewatering, rope, ballah, ghirni for cleaning of well dirty material all complete as perbuilding specition and direction of E/I |
| 47 | Dismantling plain cement or lime concrete workincludingstacking serviceble materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I (5.10.2) |
| 48 | Dismantling pucca brick or lime work including stacking serviceble materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I (5.10.1) |
| 49 | Supplying of vertical post 150 x 150 x 12 (Gr - A) (Supply)(B.C.D.P - 2) |
| 50 | Drilling 6 mm dia wholes M.S. angle iron for fixing of staples etc. as per building specification and direction of E/I. (5.5.23) |
| 51 | Labour for febricating erecting, hoisting and fixing in position structural steel work in R.S. joists, channel, angle, tee, flat, plate, latice member, built of compound section in column ,girder,stair case,or truss including cost of gusset plate,holding down bolts,anchor plates at all heights and depth , bolting ,welding(machining wherever necessary )with applying a priming coat of red lead paint all complete as per approved drawing , building specification and direction of E/I (5.5.28) |
| 52 | Providing and fixing concertina coil fancing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m) having 50 nos. rounds per 6 metre length iron \"Y\" shaped placed 2.4 m ro 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. earbed wire tied to angle iron, all complete job as per building specition and direction of E/I (D.S.R. 16.53) |
| 53 | Supplying fitting and fixing M.S. Grill gate with M.S. grils made of 20 x 6 mm M.S. flats or 16 mm M.S. square bars fitted on 20 x 25 x 6 mm M.S. angle frame - do - do - all complete as per building specification and direction of E/I (when steel is not supplied by the Deptt.) (5.5.30) |
| 54 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed with 2 mm thick PVC conduit, with modular type switch, modular plate, suitable size of GI box & earthing the point with 1.5 Sq.mm FR PVC insulated opper conductor single core cable etc as required.(J.S.R.1.3.3) Group -C. |
| 55 | Twin Control Point Wiring in PVC Conduit, with Modular type Switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box & earthing the point with 1.5 Sq.mm FR PVC insulated opper conductor single core cable etc as required. (J.S.R.1.4) |
| 56 | Power plug wiring in PVC conduit (2 x 4 sq.mm.):- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. (J.S.R1.5) |
| 57 | S/F light plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.(J.S.R.1.31) |
| 58 | S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.(J.S.R. 1.32) |
| 59 | Supply & fixing 25A SPN MCB Industrial Socket Outlet: Supply and fixing of 25A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 25 amps \"C\" series, SP MCCB, in sheet steel enclosure, on surface or in recess withchained metal cover for socket out let and complete with connections, testing and commissioning etc as required. (For split / window AC points).(J.S.R.2.18) |
| 60 | Circuit/Sub-main wiring in PVC Conduit:-Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.(J.S.R.1.7) (a) 2 x 1.5 Sqmm + 1 x 1.5 sqmm earth wire (for single separate 6A) (Circuit shall be taken from nearest switch board) (J.S.R. 1.7.1) |
| 61 | (b)2 x 2.5 Sqmm + 1 x 2.5 sq mm earth wire (for switch board circuit and 3 Nos. 6A sockets for LAN).(J.S.R.1.7.2) |
| 62 | (c)2 x 6.0 Sq.mm + 1 x 6.0 Sq.mm earth wire. (for 20A SP Industrial Scoket) ( J.S.R.1.7.4) |
| 63 | (d)4 x 10 Sq. mm + 2 x 10 Sq.mm earth wire. (to be used for TPN Normal DB Sub-Main). (J.S.R.1.7.11) |
| 64 | S/F Modular blanking plate:- Supplying and fixing of the existing modular plate and switch box excluding modular plate etc, as required. (J.S.R.1.26) |
| 65 | S/F TP MCB DB: Supplying and fixing following way, three pole and neutral sheetMCB distribution board, 415 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder paintedincluding earthing etc. as required ( But without MCB/RCCB/ ISOLATOR). (a)4 Way (4 + 12), Double Door (Horizontal Type).(J.S.R.2.9.4) |
| 66 | S/F \"C\" series MCB: Supplying and fixing 240 volts, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.(a)6/32A Single Pole (J.S.R.2.12.1) |
| 67 | (b)40A DP (J.S.R.2.12.9) |
| 68 | S/F Modular type electronic fan regulator: Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. (J.S.R.1.25) |
| 69 | S/F Ceiling Rose: Supplying andfixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. (J.S.R. 1.33) |
| 70 | S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. (J.S.R.1.34) |
| 71 | Erection of incandececent light fitting :- Erection of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS amps per fitting, complete with all accessories including connectionetc as required. (J.S.R.1.35) |
| 72 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. (J.S.R.1.41) |
| 73 | ITC fluorescent fitting with down rods:- Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.(J.S.R.1.42) |
| 74 | ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required. (J.S.R.1.44) |
| 75 | Numbering of fan / fittings:- Numbering of ceiling fan/ exhaust fan / fluorescent fittings as required. (J.S.R.1.47) |
| 76 | ITC exhaust fan upto 450 mm. sweep:- Installation of exhaust fan upto 450 mm in the existing opening, including making good the damage, connection, testing, commissioningetc. as required. (J.S.R. 1.48) |
| 77 | S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections butexcluding modular plate etc as required.(a)5/6 Amps one way switch (500 x 3-1500)(J.S.R.1.24.1) |
| 78 | (b)5/6 amps 3 pin socket out let (500 x 3 = 1500) J.S.R.1.24.4) |
| 79 | Supplying of following fans & Light fittings with high frequency, electronic Ballast with THD<10 % starter, control gears, lamps holder, power factor 0.99 for fluorscent lamp & 0.95 for CFL forimprovement, etc. as called for, including chasing of walls, grouting of fitting and making good of the same as required, complete with providing of all necessary hardares like raw plugs, hangers, support plates etc. and flexible wires as required for fixing. (a)Supply15 W led light in existing batten/angle holder. (Make :- Philips / Bajaj /Wipro).(S.O.R. M-856, P - 48) |
| 80 | Supply of recess mounted downlighter with 15W LED lamp with all accessories as per the standard Catalogue Items. (Make- Bajaj BZSLO 15W NW /Philips-DN192B LED9S-6500 PSU WH/Wipro-LD71-151-XXX-50-XX). (J.S.R. 9.3.3) |
| 81 | Supply of 1200mm Sweep, double ball-bearing, 2 canopy ceiling fanincluding connection with 1.5 sq mm copper wire, down rod all accessories as required. Make :- Bajaj 250104 / CromptonWW HE-WOR / Havells Velocity.(J.S.R.9.4.2) |
| 82 | Supply of AC 230/250 Volts, 50Hz, 300mm sweep/900 rpm ExhaustHeavy Duty Fans (Double Ball) including providing nuts- bolts, mounting frame and other required accessories etc. Make- Havells-Turbo Force / Bajaj-70069 / Crompton Greaves EXHD300-4-1 (S.O.R. Sl. 2104, P - 54) |
| 83 | Earthing with G.I. earth pipe 4.5 mtr. Key & 40 mm dia thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But without charcoal or coke and salt) (J.S.R.3.6) |
| 84 | S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as required.(J.S.R.3.7) |
| 85 | M.V. cable laying upto 25 sq. mm in ground laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KVgrade of size not exceeding 25 sq. mm but not exceeding 120 sq. mm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required. (J.S.R. 5.1) |
| 86 | Carriage of Material : (a) Cement+ Steel (Lead 20 Km.) Surface road |
| 87 | (b) Sand (Lead 30 Km.) Surface road |
| 88 | (c) Chips (Lead 20 Km.) Surface road |
| 89 | (d) Brick (Lead 01 Km. Kachha and 07 Km Surface road) |
| 90 | (d) Paver Block (Lead 01 Km. Kachha and 07 Km Surface road) |
| 91 | Goods & Service Tax (G.S.T.) - |
| 92 | Labour Cess - |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender