Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #31744879

Supplying Installation Testing Commissioning Of Evolution One Plus Spectrophotometer Double Beam Uv Visible Spectrophotometer Cdlu Sirsa Supplying Installation Testing Commissioning Of Evolution One Plus Spectrophotometer Double Beam Uv Visible Spectropho

Issued by Boards / Undertakings / PSU · sirsa, Haryana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Apr 2022
0 days left
EMD
17000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sirsa → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supplying Installation Testing Commissioning Of Evolution One Plus Spectrophotometer Double Beam Uv Visible Spectrophotometer Cdlu Sirsa Supplying Installation Testing Commissioning Of Evolution One Plus Spectrophotometer Double Beam Uv Visible Spectrophotometer Cdlu Sirsa , Evolution One Plus Spectrophotometer Double Beam Uv-Visible Spectrophotometer • Microprocessor Based Uv-Vis With Variable Bandwidth For Challenging Double-Beam Geometry For Precision Measurements. • Precision Monochromator Should Be There For Fast Scanning Data Collection And Wavelength Accuracy. System Must Also Have Feature For Application Focused Beam Geometry Option For Microcell Or Fiber Optic Probe Or Better. • Wide Accessory Selection Should Be Available With Various Temperature Control Options, Sample Changers, Sippers And Solid Sampling Devices Complete Our Analysis Should Be Available With Uv-Vis Spectrophotometer. • Spectral Bandwidth: Variable At Least Two Selection Available. • Light Source: Xenon Flash Lamp With Minimum 5 Years Of Lamp Life. • Detector: Dual Silicon Photodiodes / Pmt Or Better. • Scan Ordinate Modes: =Absorbance, % Transmittance, % Reflectance. • Range: 190 To 1100 Nm Or Better • Wavelength Accuracy: ± 0.5 Nm Or Better And Wavelength Precision Of 0.05 Nm / Min Or Better. • Scanning Speed: < 1 To 6000 Nm / Min, Variable Or Better And Slew Speed Of Atleast 30000 Nm / Min Or Better. • Data Intervals: 10, 5, 2, 1.0, 0.5, 0.2, 0.1 Nm Or Better. • Photometric Range: > 3.5 A Or Better • Photometric Accuracy 1A: ±0.004 A, 2A: ±0.08 A Or Better. • Noise: < 0.00015A Or Better. • Stray Light Kcl, 198 Nm: =1% T, Nai, 220 Nm: =0.05% T, Nano2, 340 Nm:<0.05%T. • Quartz Cell – 10Mm – 2 Pair. • Baseline Flatness Of 0.001 A Or Better. • Optional System Should Have An Option With Peltier Controlled At Least Seven Cell Changer For Temp Studies, Kinetics Etc. Should Operate From At Least 5 To 100 C With 0.5 To 10 Degree C Ramp Rate. • System Should Have Option To Upgrade With Solid Sampling Accessory, Integrating Sphere With Minimum Of 60 Mm Sphere, • System Must Be Quoted With Film Holder To Holder Film Or Thin Samples. • Training & Installation At Our Site Should Be Done Free Of Cost. • Warranty At Least 2 Years Or More. • System Should Be Ce & Iso Certified Installation Accessories Like Branded Pc, Compatible ) , 1 Kva Ups With 30 Mins Back Up Along With Latest Windows Based Os S / W Should Be Offered.

BOQ

Name of Work: Supplying/Installation/Testing/ Commissioning of Evolution One Plus Spectrophotometer-Double Beam UV-Visible Spectrophotometer, CDLU, Sirsa
Sl. No. Item Description
1Evolution One Plus Spectrophotometer Double Beam UV-Visible Spectrophotometer• Microprocessor based UV-VIS with variable bandwidth for challenging Double-beam geometry for precision measurements.• Precision monochromator should be there for fast scanning data collection and wavelength accuracy. System must also have feature for application focused beam geometry option for microcell or fiber optic probe or better.• Wide accessory selection should be available with various temperature control options, sample changers, sippers and solid sampling devices complete our analysis should be available with UV-VIS spectrophotometer.• Spectral Bandwidth: variable at least two selection available.• Light Source: Xenon flash lamp with minimum 5 years of lamp life.• Detector: Dual Silicon Photodiodes/PMT or better.• Scan Ordinate Modes: =Absorbance, % Transmittance, % Reflectance.• Range: 190 to 1100 nm or better • Wavelength Accuracy: ± 0.5 nm or better and Wavelength Precision of 0.05 nm/min or better.• Scanning Speed: < 1 to 6000 nm/min, variable or better and Slew Speed of atleast 30000 nm/min or better. • Data Intervals: 10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm or better.• Photometric Range: > 3.5 A or better • Photometric Accuracy 1A: ±0.004 A, 2A: ±0.08 A or better.• Noise: < 0.00015A or better. • Stray light KCl, 198 nm: =1% T, NaI, 220 nm: =0.05% T, NaNO2,340 nm:<0.05%T.• Quartz Cell – 10mm – 2 pair. • Baseline flatness of 0.001 A or better.• Optional System should have an option with peltier controlled at least seven cell changer for temp studies, kinetics etc. Should operate from at least 5 to 100 C with 0.5 to 10 degree C ramp rate. • System should have option to upgrade with solid sampling accessory, Integrating sphere with minimum of 60 mm sphere,• System must be quoted with film holder to holder film or thin samples.• Training & Installation at our site should be done free of cost.• Warranty at least 2 years or more.• System should be CE & ISO CertifiedInstallation accessories like Branded PC, compatible), 1 KVA UPS with 30 mins back up along with latest Windows based OS s/w should be offered.

AI Tender Summary

OUR REF NO 31744879
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 27-04-2022
Authority
Authority Name Chaudhary Devi Lal University
Work Description Supplying Installation Testing Commissioning Of Evolution One Plus Spectrophotometer Double Beam Uv Visible Spectrophotometer Cdlu Sirsa Supplying Installation Testing Commissioning Of Evolution One Plus Spectrophotometer Double Beam Uv Visible Spectrophotometer Cdlu Sirsa , Evolution One Plus Spectrophotometer Double Beam Uv-Visible Spectrophotometer • Microprocessor Based Uv-Vis With Variable Bandwidth For Challenging Double-Beam Geometry For Precision Measurements. • Precision Monochromator Should Be There For Fast Scanning Data Collection And Wavelength Accuracy. System Must Also Have Feature For Application Focused Beam Geometry Option For Microcell Or Fiber Optic Probe Or Better. • Wide Accessory Selection Should Be Available With Various Temperature Control Options, Sample Changers, Sippers And Solid Sampling Devices Complete Our Analysis Should Be Available With Uv-Vis Spectrophotometer. • Spectral Bandwidth: Variable At Least Two Selection Available. • Light Source: Xenon Flash Lamp With Minimum 5 Years Of Lamp Life. • Detector: Dual Silicon Photodiodes / Pmt Or Better. • Scan Ordinate Modes: =Absorbance, % Transmittance, % Reflectance. • Range: 190 To 1100 Nm Or Better • Wavelength Accuracy: ± 0.5 Nm Or Better And Wavelength Precision Of 0.05 Nm / Min Or Better. • Scanning Speed: < 1 To 6000 Nm / Min, Variable Or Better And Slew Speed Of Atleast 30000 Nm / Min Or Better. • Data Intervals: 10, 5, 2, 1.0, 0.5, 0.2, 0.1 Nm Or Better. • Photometric Range: > 3.5 A Or Better • Photometric Accuracy 1A: ±0.004 A, 2A: ±0.08 A Or Better. • Noise: < 0.00015A Or Better. • Stray Light Kcl, 198 Nm: =1% T, Nai, 220 Nm: =0.05% T, Nano2, 340 Nm:<0.05%T. • Quartz Cell – 10Mm – 2 Pair. • Baseline Flatness Of 0.001 A Or Better. • Optional System Should Have An Option With Peltier Controlled At Least Seven Cell Changer For Temp Studies, Kinetics Etc. Should Operate From At Least 5 To 100 C With 0.5 To 10 Degree C Ramp Rate. • System Should Have Option To Upgrade With Solid Sampling Accessory, Integrating Sphere With Minimum Of 60 Mm Sphere, • System Must Be Quoted With Film Holder To Holder Film Or Thin Samples. • Training & Installation At Our Site Should Be Done Free Of Cost. • Warranty At Least 2 Years Or More. • System Should Be Ce & Iso Certified Installation Accessories Like Branded Pc, Compatible ) , 1 Kva Ups With 30 Mins Back Up Along With Latest Windows Based Os S / W Should Be Offered.
Basic Detail
Tender No GB 1/2
Bidding Type Tender
Location
City sirsa
State Haryana
Key Dates
Publish Date 06 Apr 2022
Submission Date 27 Apr 2022
Open Date 28 Apr 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 17000
Exemption Not Available
Document List
9fd30be8-fe00-4391-a665-403e972debce.html
BOQ_283316.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 06, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 28, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9fd30be8-fe00-4391-a665-403e972debce.html

xls

BOQ_283316.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail