Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur, thrissur-Kerala

Kerala Agro Industries Corporation Limited-KAIC has published Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur. Submission Date for this Tender is 20-04-2022. Electrification Work Tenders in thrissur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

31742488
Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur
Open Tender
Indian
Kerala
thrissur
20-04-2022

Tender Details

Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur Kiifb- Electrification Of Banana And Honey Park Buildings At Kannara Thrissur

Key Value

Document Fees
INR 5900 /-
EMD
INR 50000.0 /-
Tender Value
INR 1.05 Crore /-

BOQ Items

Work Name : KIIFB- Electrificationof Banana and Honey Park at Kannara, Thrissur
Sl. No. Item Description
1WIRING
21.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
31.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
41.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
51.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
61.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
71.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
81.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
91.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
101.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
111.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
121.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excludingmodular plate as required.
131.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
141.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
151.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
161.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
171.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
181.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
19MCB"s & DB"s
202.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
212.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
22od102728/2021_2022 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>8 way (4 + 24), Double door<br><br>
23od102729/2021_2022 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>4 way (4 + 12), Double door<br><br>
24od102730/2021_2022 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>6 way (4 + 18), Double door<br>
25od102731/2021_2022 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>4 way (4 + 12), Double door<br>
26od102732/2021_2022 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)<br>12 way (4 + 36), Double door<br>
272.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
282.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
292.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required.
302.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
312.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
32od102733/2021_2022 : Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.<br>
33MV & HT CABLE LAYING
347.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
357.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
367.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm
377.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
387.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
397.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
407.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
417.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
427.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
437.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
447.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.
45HT CABLE LAYING
468.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
478.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
488.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
49MV & HT CABLESEND TERMINATION
509.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
519.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
529.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
539.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
549.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
559.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
569.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
579.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
589.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
59od102744/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>4cx6 sq mm<br><br>
60od102745/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>4cx4sq mm<br><br>
61od102748/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>2cx4 sq mm<br>
62od102749/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>12Cx2.5 Sqmm Control cable<br>
63LT CABLE SUPPLY
64od103678/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 12x2.5sq.mm Cu Control Cable<br><br>
65od103743/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2x4sq.mm Al Cable<br><br>
66od103746/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.4x4sq.mm Al Cable<br>
67od103748/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.4x16sq.mm Al Cable<br>
68od103747/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.4x6sq.mm Al Cable<br>
69od103749/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.4cx25sq.mm Al Cable<br>
70od103750/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx35sq.mm Al Cable<br>
71od103751/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx50sq.mm Al Cable<br>
72od103752/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx70sq.mm Al Cable<br>
73od103753/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx95sq.mm Al Cable<br>
74od103755/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx150sq.mm Al Cable<br>
75od103756/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx185sq.mm Al Cable<br>
76CABLE TRAY
77od103757/2021_2022 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall begalvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>100 mm width X 60mm Height<br>
78od103759/2021_2022 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall begalvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>150 mm width X 60mm Height<br>
79od103761/2021_2022 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall begalvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>200 mm width X 60mm Height<br>
80od103762/2021_2022 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall begalvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>300 mm width X 60mm Height<br>
81od103763/2021_2022 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall begalvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>400 mm width X 60mm Height<br>
82od103764/2021_2022 : Supply and fixing of Perforated Cable tray with all accessories including horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall begalvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a maximum safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. <br>500 mm width X 60mm Height<br>
83HT SECTION
84od103767/2021_2022 : "Supply, erection, testing and commissioning ofdust and vermin proof, floor mounted, free standing cubicle type, communicable type 11kV Metal Enclosed Outdoor Extensible at one end, Compact Ring Main Unit add-on made out of robotically welded stainless steeltank of IP67 class of protection fully compartmentalized complete with hinged and earthedfrontdoors interlocked with the earth switch. The switch-gear should have the minimum degree of protection (in accordance with IEC 60529) <br>- IP 67 for the tank with high voltage components <br>- IP 54 for the front covers of the mechanism <br>- IP54 for the cable connection covers"<br>The unit consisting of 11kV, 630A, 20 kA, Motor operated, Compact, Outdoor with O/C & EF self powered Relays, Extensible at both side, Non drawout type, CVC + (Fixed type motor operated Vacuum Circuit Breaker (VL) outgoing). Rate shall be inclusive of pre-commissioning test - providing all accessories and requirements for successful pre-commissioning of unit, as instructed by engineer in charge/consultant and in accordance with all relevant standards and requirements.<br>
85od103769/2021_2022 : METERING CUBICLE WITH TOD METER <br>Supply, erection, testing and commissioning of dust and vermin proof, floor mounted free standing cubicle type 11kV outdoor metering panel box, fully compartmentalised complete with hinged and earthed front doors interlocked with earth switch with 3 phase 4 way 110V (L-L), 5A, class: 0.2 S, TOD meter with RS485 port, of Electricity board approved make including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities,providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant. Also the panels unit shall comprise of 3 Nos CT's of 10VA burden, and class Cl: 0.2 S and ratio depending on contract demand including fixed type PT of ratio 11kV/110V, 25VA, Cl: 0.2 (1 No.) and seal off bushings, space heater with thermostat including 400A Aluminium busbars with support insulators and all other accessories as required for complete installation as required and instructed by engineer in charge/consultant. <br>
86HT CABLE SUPPLY
87od103772/2021_2022 : Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. <br>3 C x 300 Sq.mm XLPE Cable<br>
88HT CABLE END TERMINATIONS
89od103773/2021_2022 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.<br>3C x 300 sq.mm.<br>
90od103777/2021_2022 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.<br>3C x 300 sq.mm.<br>
91UNITISED SUBSTATION - 250 kVA 11kV/433V Cast Resin (Dry type)
92od103778/2021_2022 : Supply, installation, testing & commissioning of 250 kVA 11kV/433V indoor cast resin dry type transformer (copper double wound) including 11kV, 630A, 26.3 kA, Load Break Switch, HT HRC Fuse, Seal off Bushing, Al Bus Bar with support insulatiors, wiring, erthing etc. at primary side having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with tapping +5% to -10% in steps of 2.5% by tap links, changeable on offcircuit by tap links provided, include separate winding temperature indicator for each phase andcore in the Transformer. Transformer should have cable end box on HV side suitable for 3CX300 sq.mm XLPE cable and suitable end box on LV side for connecting 2R X 3.5C X 185 Sqmm Al Cable, with all accessories, complete as required as per State electricity board, ECBC, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/1985 with latest amendment etc complete. Foudation for TXR shall be done by other agency.<br>
93DIESEL GENERATORS
94od103793/2021_2022 : Installation, testing and commissioning of 3phase, 415V, 0.8pf 50hz. radiator cooled DG set of the rating 200 kVA Diesel Generating Set.<br>
95od103795/2021_2022 : EXHAUST PIPES<br>Supply, erection, commissioning of additional length ofexhaust pipes for following DG sets with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps angle, channel, I section, necessary nut and bolt and all required accessories including cutting, hoisting, fixing in position and applying 2 coats of primer and 2 coats of enamel paint of approved quality etc as required in the steel works etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.For 200 kVA DG Set<br><br>
96AUTO POWER FACTOR CORRECTION
97od103797/2021_2022 : APFC PANEL<br>Supply erection, testing and commissioning of 14 SWG freestanding indoor cubicle, type testedautomatic power factor control panel of rating 80 kVAr with 7% harmonic reactor with tuned capacitors using capacitor swtiching. By using Microprocessor based relay operated controller with minimum 7 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching. 200A, 25kA 4P MCCB withhigh rupturing capacity and in built overload and short circuit releases as per specificationsas incomer, housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes in steps of 7 (20 kVAr X 1), (15 kVAr X 2), (10 kVAr X 2) & (5 kVAr x 2) required rating of capacitor shall be directly connected to the main bus for no load compensation with the co-ordination of transformer manufacturer specification. <br>"The capacitors shall be with U.L listed pressure sesitive interrupter, inside hermctically sealed metal cans. with terminal bushings to withstand 10 KV AC to ground with treated terminals and capacitor cells shall be provided with discharge resistors to reduce residual voltage <50V within one min of de-energisation. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCB shall be used for individual stage control. <br>Metering :Digital Multi Function Meter(DMFM) , Push Button, R Y B Indication with control fuse -1Set, Automanual selector switch- 1No, Forced cooling using fans, APFC relay - 1 no. including all connections and interconnections, all accesories as required for complete installation as instructed by engineer in charge."<br>
98LT PANELS
99od103799/2021_2022 : MAIN PANEL<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV Main panel boardmade out of 14 SWG thick CRCAsheet(7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should include Pluggable type surge arrester Class B & Class C / Class 1 & Class 2 as per IEC 61643 (IP 20) with potential free contact, completely assembledenclosure & provision for inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage - 230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV (N to E). Operating temp -40º to +85ºC. Response time <100nano secincluding necessary MCCB for protection of same. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.<br>Incomers<br>EB Incomer 1 - 400A 36kA FP Microprocessor based MCCB having isolation duty and E/F relay with CT at neutral earthing conductor + 400A FP Contactor - 1 Set.<br>DG Incomer 1 - 320A 36 kA FP Microprocessor based MCCB Standby low set E/F relay with CT at neutral earthing conductor + 320A FP Contactor - 1 Set.<br>400A 415V, 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage,Current, Frequency, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts, Phase angle, THD, Neutral current, Max Demand (with RTC),Events (high-low) with time stamp,Individual Harmonics upto 31st, Meter with Ethernet port - 2 Sets.<br>Supply, erection, testing & commisioning of AMF for DG set, including necessary SMPS, AUX contactor or Relay, Relay Module, DIN Rail, Selector Switch, Push Button, Terminal, Indication lamp, Legs, End plate, Stopper, 1.5 Ferule, Screw, Neutral link, 2.5 Sqmm wire,1.5Sqmm wire, Cable tie, Tie mount and all other accesories and componets as required for complete installationand as instructed by engineer in charge/consultant.<br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Class B & Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC Fuse for back-up protection - 1 No.<br>Outgoings<br>200A 25kA TP Microprocessor BasedMCCB- 1 No.<br>125A 25kA TP Microprocessor BasedMCCB- 1 No.<br>125A 25kA FP Termal MagneticBasedMCCB + 125 A Fuse unit + Three phase LT TOD meter with necessary CT and PT units etc including connections and interconnections with all accessories required for complete installation. - 1 Set<br>100A 25kA TP Microprocessor BasedMCCB- 3 Nos.<br>80A 25kA TP Microprocessor BasedMCCB- 1 No.<br>63A 25kA TP Microprocessor Based MCCB - 5 Nos.<br>200 A TP Isolator - 1 No<br>Supply, Installation, testing and commisioning<br>
100od103800/2021_2022 : BANANA MCC<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 14 SWG thick CRCAsheet(7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should includepluggable type surge arrester in suitable enclosure Class B+C / Class 1+2as per IEC 61643 (IP 20)with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 100 A, 25kA FP Thermal Magnetic BasedMCCB- 1 No.<br>100A 433V, 50kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh<br>Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>32A, TP+NL, MCB - 2 Nos.<br>25A, TP+NL, MCB - 1 No.<br>16A, TP+NL, MCB - 1 No.<br>10A, TP+NL, MCB - 5 Nos.<br>6A, TP+NL, MCB - 7 Nos.<br>Supply, Installation, testing and commisioning<br>
101od103803/2021_2022 : CHIPS MCC<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 14 SWG thick CRCAsheet(7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should includepluggable type surge arrester in suitable enclosure Class B+C / Class 1+2as per IEC 61643 (IP 20)with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 100 A, 25kA FP Thermal Magnetic BasedMCCB- 1 No.<br>100A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh<br>Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoings<br>32A, TP+NL, MCB - 1 Nos.<br>25A, TP+NL, MCB - 3 Nos.<br>16A, TP+NL, MCB - 3 Nos.<br>10A, TP+NL, MCB - 3 Nos.<br>6A, TP+NL, MCB - 5 Nos.<br>Supply, Installation, testing and commisioning<br>
102od103804/2021_2022 : WINE MCC<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted)as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV common Service panel board made out of 14 SWG thick CRCAsheet (7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should includepluggable type surge arrester in suitable enclosure Class B+C / Class 1+2as per IEC 61643 (IP 20)with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth, Nominal discharge current - 30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 80 A, 25kA FP Thermal Magnetic BasedMCCB- 1 No.<br>80A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement.<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1 Set.<br>Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 Set.<br>Outgoings<br>25A, TP+NL, MCB - 2 Nos.<br>16A, TP+NL, MCB - 6 Nos.<br>10A, TP+NL, MCB - 4 Nos.<br>6A, TP+NL, MCB - 2 Nos.<br>Supply, Installation, testing and commisioning<br>
103od103814/2021_2022 : HONEY PARK (HP) - MSB<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted/wall mounted, front operated MV panel boardmade out of 16 SWG thick CRCAsheet(7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br> This panel should includepluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2as per IEC 61643 (IP 20)with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 125 A, 25kA FP Thermal Magnetic BasedMCCB- 1 No.<br>125A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set<br>Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing<br>63A 16kA TP Thermal Magnetic BasedMCCB- 4 Nos.<br>40A 16kA TP Thermal Magnetic BasedMCCB- 2 Nos.<br>Supply, Installation, testing and commisioning<br>
104od103819/2021_2022 : HONEY MCC - 1<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 16 SWG thick CRCAsheet(7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should includepluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2as per IEC 61643 (IP 20)with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 63 A, 16kA FP Thermal Magnetic BasedMCCB- 1 No.<br>63A, 415V, 25 kA best conductivity Al TPN bus barwith SMC supports, heat shrinkable sleeves etc complete as required. <br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set<br>Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing<br>32A, TP+NL, MCB - 2 Nos.<br>25A, TP+NL, MCB - 2 Nos.<br>16A, TP+NL, MCB - 1 No.<br>10A, TP+NL, MCB - 4 Nos.<br>Supply, Installation, testing and commissioning<br>
105od103820/2021_2022 : HONEY MCC - 2<br>Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel boardmade out of 16 SWG thick CRCAsheet(7 tank treatment) fully compartmentalised complete with hinged and earthedfrontdoors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.<br>This panel should includepluggable type surge arrester in suitable enclosure Class B+C/ Class 1+2as per IEC 61643 (IP 20)with potential free contact, thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - 21 kA (10/350µ sec) for Line to Neutral & 25 kA(10/350µ sec) for Neutral to Earth,Nominal discharge current-30 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 150 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth. Voltage protection level 1300V (L to N) & 1200V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed.<br>Incomer - 63 A, 16kA FP Thermal Magnetic BasedMCCB- 1 No.<br>63A, 415V, 25 kA best conductivity Al TPN bus barwith SMC supports, heat shrinkable sleeves etc complete as required. <br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set<br>Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing<br>32A, TP+NL, MCB - 1 No.<br>25A, TP+NL, MCB - 1 No.<br>16A, TP+NL, MCB - 6 Nos.<br>10A, TP+NL, MCB - 3 Nos.<br>Supply, Installation, testing and commissioning<br>
106LIGHT & FAN FIXTURES- INTERIOR
107od103827/2021_2022 : Supply of Integral, SMD LED, IP40, 40W Surface Mounted LED Batten with System efficacy of more than 100 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum five years. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Similar to Wipro Model No. LL24-541-XXX-57-XX or equivalent.<br>
108od103828/2021_2022 : Supply of Integral, SMD LED, IP40, 20 W Surface Mounted LED Batten with System efficacy of more than 100 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum five years. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than or equal 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Si,ilar to Wipro Model No. LL24-251XXX-57-XX or equivalent<br>
109od103829/2021_2022 : Supply of Integral, SMD 1x4 LED, IP 20, 36W LED Surfacemounted fixture with System efficacy of more than 100lm/W and system lumen output 3600lm.  Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia / Cree / Bridgelux / Lumileds should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Complying to SELV < 60V DC standards. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Similar to Wipro Model No.CRCO13S036HP57GL1 or Equivalent.<br>
110od103834/2021_2022 : Supply of LED HIGHBAY 60 Deg Beam Angle, 160W (+/-10%) High efficient Suspesned TypeLED Highbay wAluminium Die cast Housing, polycarbonateHigh transmittivity IP . CRI>70, IP65 & IK08 rated , Ambient temp-0 to 45DegC, CCT - 5700K, LED Life of 100,000 hrs @ L70B50 Driver efficiency>85%, THD<=10%, Powerfactor>=0.95, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage operated Potted driver with Input voltage range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 21600 Lumens (135 Lm per watt System efficacy). Similar to Wipro Radial UNO LED 160W 60W Deg Beam Angle : LH21-262-060-57-XX or equivalent.<br>
111od103835/2021_2022 : Supply of LED HIGHBAY 60 Deg Beam Angle, 120W (+/-10%) High efficient Suspesned TypeLED Highbay wAluminium Die cast Housing, polycarbonateHigh transmittivity IP . CRI>70, IP65 & IK08 rated , Ambient temp-0 to 45DegC, CCT - 5700K, LED Life of 100,000 hrs @ L70B50 Driver efficiency>85%, THD<=10%, Powerfactor>=0.95, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage operated Potted driver with Input voltage range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 16200 Lumens (135 Lm per watt System efficacy). Similar to Wipro Radial UNO LED 120W 60W Deg Beam Angle : LH21-192-060-57-XX or equivalent.<br>
112od103837/2021_2022 : Supply of LED HIGHBAY 60 Deg Beam Angle, 100W (+/-10%) High efficient Suspesned TypeLED Highbay wAluminium Die cast Housing, polycarbonateHigh transmittivity IP . CRI>70, IP65 & IK08 rated , Ambient temp-0 to 45DegC, CCT - 5700K, LED Life of 100,000 hrs @ L70B50 Driver efficiency>85%, THD<=10%, Powerfactor>=0.95, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage operated Potted driver with Input voltage range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 13500 Lumens ( 135 Lm per watt System efficacy). Similar to Wipro Radial UNO LED 100W 60W Deg Beam Angle : LH21-162-060-57-XX or equivalent.<br>
113od103838/2021_2022 : Supply of LED HIGHBAY 60 Deg Beam Angle, 80W (+/-10%) High efficient Suspesned TypeLED Highbay wAluminium Die cast Housing, polycarbonateHigh transmittivity IP . CRI>70, IP65 & IK08 rated , Ambient temp-0 to 45DegC, CCT - 5700K, LED Life of 100,000 hrs @ L70B50 Driver efficiency>85%, THD<=10%, Powerfactor>=0.95, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage operated Potted driver with Input voltage range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 10800 Lumens ( 135 Lm per watt System efficacy). Similar to Wipro Radial UNO LED 80W 60W Deg Beam Angle : LH21-122-060-57-XX or equivalent.<br>
114od103839/2021_2022 : Supply of LED DOWNLIGHT: 18W (+/-2W) High efficient Surface mounted LED round downlighter withwhite powder coated polycarbonate Surface Housing with pressure die cast aluminium heat Sink. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<=10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminaire lumen ≥ 1800 lm. (100 lm/W). Si,ilar to Wipro make Cat Ref : LD06-221-XXX-57SMG1 or equivalent.<br>
115od103840/2021_2022 : Supply of LED DOWNLIGHT: 12W (+/-2W) High efficient Surface mounted LED round downlighter withwhite powder coated polycarbonate Surface Housing with pressure die cast aluminium heat SinkHigh transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<=10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminaire lumen ≥ 1200 lm. (100 lm/W). Similar to Wipro make, Cat Ref : LD06-151-XXX-57SMG1 or equivalent.<br>
116od103841/2021_2022 : Supply of LED DOWNLIGHT: 9W (+/-2W) High efficient Surface mounted LED round downlighter withwhite powder coatedpolycarbonate Surface Housing with pressure die cast aluminium heat Sink. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<=10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminaire lumen ≥ 900 lm. (100 lm/W). Similar to Wipro make, Cat Ref: LD06-111-XXX-57SMG1 or equivalent.<br>
117od103843/2021_2022 : Supply of LED DOWNLIGHT: 6W (+/-2W) High efficient Surface mounted LED round downlighter withwhite powder coated, polycarbonate Surface Housing with pressure die cast aluminium heat Sink. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<=12%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminaire lumen ≥ 600 lm. (100 lm/W). Similar to Wipro make, Cat Ref: LD06-670-XXX-57SMG1 or equivalent.<br>
118EXTERIOR LIGHT FIXTURES
119od103847/2021_2022 : Supply, fixing, testing and commissioning of 5 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate diamentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. <br>The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 45 W LED fixture (Similar to Wipro make : LR02-501-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole, foundation etc. required as per the specification.<br>
120od103848/2021_2022 : Supply, fixing, testing and commissioning of 3 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate diamentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. <br>The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 25 W LED fixture (Similar to Wipro make : LR02-501-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole, foundation etc. required as per the specification.<br>
121FAN FIXTURES
122od103849/2021_2022 : Supplying of ceiling fan of 1200mm sweep, energy efficient 5 Star rated, BLDC motor, High Speed, high power factor above 0.95 includingthe down rod of standard length (upto30 cm). Similar to Efficiencia Neo (BLDC 26 W) or equivalent.<br>
123od103850/2021_2022 : Supply, installation, testing and commissioning of wall fan of 450 mm sweep silver black, 1400 RPM, Oscillation degree 60, 110 Cu.Mtr/Min Air delivery. Fan with pull cords for speed regulation & wide oscillation control. Aerodynamically designed blades for high air efficiency. Similar to Havells V3 or equivalent.<br>
124od103851/2021_2022 : Supply, installation, testing and commissioning of Exhaust fan of 150mm sweep, 2000 RPM, 275 Cu.Mtr/Min Air delivery. Similar to Havells Make VENTIL AIR HUSH or equivalent.<br>
125MISCELLANEOUS
126od104942/2021_2022 : PVC FLEXIBLE CONDUIT<br>Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>25mm dia <br>
127od104943/2021_2022 : PVC FLEXIBLE CONDUIT<br>Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>20mm dia <br>
128od104945/2021_2022 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity currentin the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as requiredand instructed by engineer in charge/consultant..<br>25A 100mA DP RCBO<br>
129od104946/2021_2022 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity currentin the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as requiredand instructed by engineer in charge/consultant..<br>32A 100mA DP RCBO<br>
130od104947/2021_2022 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity currentin the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as requiredand instructed by engineer in charge/consultant..<br>40A 100mA FP RCBO<br>
131od104948/2021_2022 : RCBO<br>Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity currentin the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as requiredand instructed by engineer in charge/consultant..<br>25A 30mA FP RCBO<br>
132od104950/2021_2022 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>63 Amp 25kA FP MCCB with Thermal - Magnetic Release<br>
133od104951/2021_2022 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, type MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>80 Amp 25kA FP MCCB with Thermal - Magnetic Release<br>
134od104952/2021_2022 : Computer Point<br>Wiring for computer point using 2 Nos 6A plug points controlled by 2 Nos independent 6A switches using 1.5 sq.mm FRLS PVC insulated coppersingle core stranded wireand earthing using using 1.5 Sqmm FRLS PVC insulated coppersingle core stranded wire, green colour continuous run thorough conduit as per IS, earthing etc in surface/ recessed medium class PVC conduit including all accessorizes as required for complete installation and as directed by engineer in charge and making good all damages made for installation. Cost inclusive of sockets, switches, suitable cover plate and base plate and suitable size GI box with all accessories required for complete installation etc. Circuit main shall be measured separately<br>
135od104953/2021_2022 : Isolator With Enclosure<br>Supply and fixing of following FP 415V, MCB / MCCB isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>6-25A FP MCB Isolator with enclosure<br>
136od104955/2021_2022 : Isolator With Enclosure<br>Supply and fixing of following FP 415V, MCB / MCCB isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>32A FP MCB Isolator with enclosure<br>
137od104956/2021_2022 : Isolator With Enclosure<br>Supply and fixing of following FP 415V, MCB / MCCB isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>40A FP MCB Isolator with enclosure<br>
138od104957/2021_2022 : Isolator With Enclosure<br>Supply and fixing of following FP 415V, MCB / MCCB isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.<br>63A FP MCCB Isolator with enclosure<br>
139od104958/2021_2022 : MCB<br>Supply, installation, testing and commisioning of following rating SP/TP C curve MCB, 16kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. <br>40A TP MCB<br>
140LIGHTNING & EARTHING PROTECTION
141od104961/2021_2022 : LIGHTNING PROTECTION<br>Supply, installation and tesing of2 meter air terminal with accessories: Providing and fixing Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod 2 meter rod: Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) 101 VL 2000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked.<br>
142od104962/2021_2022 : Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications (Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotetial bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. Can be used outdoor also. Screw and crossbar made of VA. Capable of carring lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accesories as required for complete installation as instructed by engineer in charge.<br>
143od104967/2021_2022 : Supply and laying hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from earth electrode directly in ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including cross connectors and all accesories as required for complete installation as instructed by engineer in charge.<br>
144od104969/2021_2022 : Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessories as required.<br>
145od104973/2021_2022 : Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.<br>
146od104983/2021_2022 : Supply, installation and testing of maintenance free Earthing system as per IS 2309 ,IEC 62305 part3, IEC 60364, IEC 62561 part 2, IS 3043, UL 467 & UL 96 standards.Earthing System comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length (1m (219 20 CU) x 3 nos), having a diameter of 20mm with copper coating thickness of 250 microns with self-coupling bore and pegarrangement (without the need for external coupler) with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA.For obtaining desired length, the number of rods shall be increased and is provided with Universal Clamp (2730 20 VA) made of SS 304 for clamping the cable/flat conductor to the rod. Impact point (219 20 IP) on the bottom rod for easy insertion. Earth enhancing mineral compound (ECS PB 12.5) is used for improving the soil conductivity. <br>Earth enhancing mineral compound shall be so designed and constructed that in normal use their performance is reliable and without danger to persons and the surroundings. The material shall be mineral inert to sub soil and shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low resistivity. It shall not be corrosive to the earth electrode itself. The material should have a resistivity less than 0.2 Ohm meter. It should be free from hazardous substances The mineral compound is required to have minimum 12.5 Kg of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 190mm with a weight bearing capacity of 5KN, including all accesories as required for complete installation as instructed by engineer in charge.<br>
147od104993/2021_2022 : Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia withfunnel having20G GI wire mesh etc. The CI cover frame/ chamber shall beof 1000mm x 500mm x 600mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. (Value of earth resistance should be less than 1 ohm )<br>
148od104994/2021_2022 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant.<br>25x3 Cu strips tinned at the joints<br>
149od104996/2021_2022 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant.<br>25x6 Cu strips tinned at the joints<br>
150od105015/2021_2022 : Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as requiredfor complete installation as instructed by engineer in charge/consultant.<br>25x3 Cu strips tinned at the joints<br>
151od105016/2021_2022 : Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as requiredfor complete installation as instructed by engineer in charge/consultant.<br>Copper wire No.8 SWG <br>
152SAFETY EQUIPMENTS
153od105036/2021_2022 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.<br>
154od105039/2021_2022 : Supply and providing2/3 mm thick sythetic type and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969.<br>
155od105040/2021_2022 : Supply and providing First Aid Box.<br>
156od105042/2021_2022 : Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc.<br>
157od105043/2021_2022 : Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.<br>
158od105044/2021_2022 : Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.<br>
159od105048/2021_2022 : Supply and providing12 mmthick and 1 m wide electrical grade chequered type rubber mat to withstand 11 kV dielectric strength conforming to IS 5429/1969 <br>
160od105049/2021_2022 : Supply of 1 pair 11 KV rubber hand gloves of approved make.<br>
161od105050/2021_2022 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and goldor , duly painted over a coat of primer. Cost inclusive of providing 3 Nos of fire buckes and MS stand frame.<br>
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail