}

Laying Of Additional D.I. ( K7 ) Pipe With Specials Of 100 Mm Dia, 300 Mm Dia An 200 Mm Dia, Including Supply And Installation Of Valves With Construction Of Valve Chambers And Temporary Road Restoration With Ancillary Works For Distribution Lin, bhatpara-West Bengal

Urban Local Bodies has published Laying Of Additional D.I. ( K7 ) Pipe With Specials Of 100 Mm Dia, 300 Mm Dia An 200 Mm Dia, Including Supply And Installation Of Valves With Construction Of Valve Chambers And Temporary Road Restoration With Ancillary Works For Distribution Lin. Submission Date for this Tender is 03-05-2022. Pipe Laying Tenders in bhatpara West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

31742298
Corrigendum : Laying Of Additional D.I. ( K7 ) Pipe With Specials Of 100 Mm Dia, 300 Mm Dia An 200 Mm Dia, Including Supply And Installation Of Valves With Construction Of Valve Chambers And Temporary Road Restoration With Ancillary Works For Distribution Lin
Tender
Indian
West Bengal
Bhatpara
03-05-2022

Tender Details

Laying Of Additional D.I. ( K7 ) Pipe With Specials Of 100 Mm Dia, 300 Mm Dia An 200 Mm Dia, Including Supply And Installation Of Valves With Construction Of Valve Chambers And Temporary Road Restoration With Ancillary Works For Distribution Line In Wa , Excavation Of Trial Pit ( 3.0 M X 1.0 M X ( Upto ) 3.0 M ) For Fixing Of Pumping Main, Washout Line Raking Every Detection Against Damage Of S.W. Pipe Line Electrical Cable Etc. As Underground Obstruction Including 37.5 Mm Timber Shuttering, Earth Cutting, Dewatering, Barricading And Back Filling Etc. As Per Direction Of E-I-C. , Picking Up And Removing Old Bituminous Layer Or Sand Sealing Coat From Old Black Topped Surface And Cleaning The Exposed Surface By Scraping And Stacking The Material As Directed. A ) By Manual Means: ( I ) From 50 Mm To 100 Mm Thick. , Labour For Picking Up Existing Metalled Road Surface To A Specifiedaverage Depth Including Screening And Stacking The Pavement Materials.A ) For Average Depth Above 40 Mm But Not Exceeding 75 Mm By Manual Meansi ) Stone Metal Surface , B ) For Average Depth Above 40 Mm But Not Exceeding 75 Mm By Manual Means: I ) Bricks / Jhama Metal Surface , Dismantling All Type Of Plain Cement Concrete Works, Stacking Serviceable Materials At Site And Removing Rubbish As Directed With In A Lead Of 75 M In Ground Floor Including Roof. , Labour For Taking Out Old Solingedging Including Removing Debris. ( A ) Single Flat Soling. , Earth Work In Excavation In Foundation Trenches Or Drains In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spils Within A Lead Of 75M. As Directed.The Item Includes Necessary Trimming The Sides Of Trenches Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.A ) Depth Of Excavation Not Exceeding 1500 Mm. , Hire And Labour Charges For Shoring Work ( Including Necessary Close Plank Walling, Framing, Eucalyptus / Jhou Bulla Piling, Strutting Etc. ) Complete As Per Direction Of The Engineer-In Charge For Foundation Excavation. ( Vertical Surface Area In Contact With Supported Earth Is To Be Measured. ) ( This Item Should Be Executed On Specific Direction Of The Engineer-In-Charge. ) ( A ) Depthup To 1.50 M. Below G.L. , Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm. As Directed And Consolidating The Same By Thorough Saturation With Water Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On Measurement Of Finished Quantity ) . , Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level And Filling Joints With Powdered Earth Or Local Sand. , Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. ( I ) Pakur Variety. , Brick Work With 1St Class Brick In Cement Mortar ( 1:6 ) A ) In Foundation & Plinth. , Hire And Labour Charges For Shuttering With Centering And Nece­Ssary Staging Upto 4 M. Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs, Beams & Co­Lumns, Lintels Curved Or Stra­Ight Including Fitting Fixing And Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) A ) 25 Mm To 30 Mm Shuttering Without Staging In Foundation. , Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. ( I ) Pakur Variety. , Reinforcement For Reinforced Concrete Work Inall Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundation, And Upto Roof Of Ground Floor / Upto 4 M ( I ) Tor Steel / Mild Steel, Ii. Jsw / Jspl / Shyam / Srmb / Bmasl / Elecrosteel / Ssl , Plaster ( To Wall, Floor, Ceiling Etc. ) With Sand And Cement Mor­Tar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course Scaffolding Staging Where Necessary ( Ground Floor ) [ Excluding Cost Of Chipping Of Concrete Surface ) A ) With 1:4 Cement Mortar. Ii ) 20 Mm Thick Plaster. , Neat Cement Punning About 1.5 Mm. Thick In Wall, Dado, Window, Sills, Floor Etc.Note:Cement 0.152 Cu.M Per 100 Sq.M. , Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) ( A ) With Earth Obtained From Excavation Of Foundation. , Lowering Any Type Of Ductile Iron ( Di ) Pipes & Specials And Laying Along Trench At Any Depth As Per Speclfication And Direction Of The Engineer-Incharge, ( Laying Over Ground. The Rates Shall Be, Reduced By 10% And The Rates So Reduced Shall Be Inclusive Of Cost Of All Sorts Of Holding Arrangements ] ( Diameter In Mm ) A ) 100Mm Dia. , B ) 150Mm Dia. , C ) 200Mm Dia. , Rubber Gasket Joints To C.L. / D.L. Pipes And Specials All Complete To Makes The Joint Water Tight As Required Hydraulic Pressure As Per Specification And Direction Of The Engineer-In-Charge. [ Cost Of Rubber. Gasket Of Approved Make Induding Supply To Any Point Within The Kolkata Municipal Area Shall Be Paid Separately. ] A ) 100Mm Dia. , B ) 150Mm Dia. , C ) 200Mm Dia. , Cutting Of C.L / D.I Pipes For Fitting With Pipes And-Or Specials Of Similar Or Dissimilar Materials At The Time Of Laying Without Damaging Any Part Of The Required Length Including Taking Out Of The Broken Pieces From The Trench And Restacking The Same At The Specified Location As Per Direction Of The Engineer-In-Charge. A ) 100Mm Dia. , B ) 150Mm Dia. , C ) 200Mm Dia. , Chamfering The Spigot End Of C.L. / D, L. Pipes For Fitting With The Socket Of C.I. / D.I Pipes And / Or Specials In Tyton Jointed Water Mains Or Other Wise Using Electric Grinder As Per Specification And Direction Of The Engineer-In-Charge.A ) 100Mm Dia. , B ) 150Mm Dia. , C ) 200Mm Dia. , Flange Joint To C.L. / D.L / Ms. Pipes And Specials Including Supply Of Rubber Gasket. Nuts. Bolts. Washers Etc. Of Best Quality To Make The Joint Watertight At Required Hydraulic Pressure All Complete As Per Specification & Direction Of The Engineer-In-Charge. A ) 80Mm Dia. , B ) 100Mm Dia. , C ) 150Mm Dia. , D ) 200Mm Dia. , All Types Of Ductile Iron ( D.I ) Specials ( Viz. Bend. Tee. Taper. Tail Piece Etc ) , Size Conforming To I.S. Specification No. 9523 / 2000 With Cement Mortar Lining ( Inside ) And Bituminous Coating ( Outside ) . ( 25% Of Payment Will Be Held Up Till Successful Hydraulic Testing ) A ) All Socket Tee100 Mm To 300 Mm Dia. , B ) Doubled Socketed Bend100 Mm To 300 Mm Dia. , Supply Of Single / Double Bit Sbr Gasket Suitable For Jointing Ci / Di Pressure Pipes, Conforming To Is : 5382 : 1985 [ Popularly Known As ‘Tyton Gasket ] A ) 100Mm Dia. , B ) 150Mm Dia. , C ) 200Mm Dia. , Carriage Of Ci / Dl / Erwms / Ac Pipes Including Loading Into Truck At The Lifting Point, Unloading At Destination And Stacking Properly In Godown Or Yard Etc. As Directed ( Including Carriage By Head Load Upto 30 Metres At Each Of The Two Points. The Rate Covers All The Above Operations, Actual Transport All Complete ) ( A ) 100 Mm Dia.Upto5 Km. , Per Km Beyond 5 Km To 10 Km. , Per Km Beyond 10 Km To 20 Km. , ( B ) 150 Mm Dia. Upto5 Km. , Per Km Beyond 5 Km To 10 Km. , Per Km Beyond 10 Km To 20 Km. , ( C ) 200 Mm Dia.Upto5 Km. , Per Km Beyond 5 Km To 10 Km. , Per Km Beyond 10 Km To 20 Km. , Sypply Of E.R.W.M.S. ( Electrical Resistant Welded M.S. ) Black Pipe Of Isi Mark As Per Relevent Is Specification ( Heavy Quality ) Having Wall Thickness Not Less Than 5 Mm. [ N.B.: The Rates For Supply Of Tata Make Pipe Will Be Arrived At By Adding 20% Of The Corresponding Rates ] ( A ) 80 Mm Dia. [ Basic Price = Rs. 697 / - Per M. ] , ( B ) 100 Mm Dia. [ Basic Price = Rs. 871 / - Per M. ] , ( C ) 150 Mm Dia. [ Basic Price = Rs. 1, 268 / - Per M. ] , Sypply Of E.R.W.M.S. ( Electrical Resistant Welded M.S. ) Black Pipe Of Isi Mark As Per Relevent Is Specification ( Heavy Quality ) Having Wall Thickness Not Less Than 5 Mm. [ N.B.: The Rates For Supply Of Tata Make Pipe Will Be Arrived At By Adding 20% Of The Corresponding Rates ] ( A ) 200 Mm Dia. [ Basic Price = Rs. 697 / - Per M. ] , Supply Of M.S. Flange ( Slipper Type ) As Per Is-6392 Table 17 Thickness 12Mm. 80Mm , 100Mm , 150Mm , 200Mm , Supply Of M.S. Flange ( Slipper Type ) As Per Is-6392 Table 20 Thickness 12Mm. 80Mm , 100Mm , 150Mm , 200Mm , Derusting, Scraping, Brushing And Cleaning ( To The Extent Of Exposing The Original Surface ) The Outer Surface Of Manufactured M.S. Pipes And Specials. Applying First Coat Of Synthetic Primer Type-B As Per Is : 15337 : 2003 Of Approved Make Over It And Wrapping The Same With Coal Tar Based Insulating Tape 2 Mm Thick As Per Is : 15337 : 2003 Of Approved Make And Applying The Second Coat Of Synthetic Primer Type - B ( As Specified Above ) Over The First Layer Of Insulating Tape And Wrapping The Same With Second Layer Of 2 Mm Thick Coal Tar Based Insulating Tape ( As Specified Above ) In Staggered Pattern ( Including Overlapping At Ends ) By Torching Etc. As Per Manufacturers Specification And As Per Direction Of Elc. Each Layer Of Protective Wrapping Shall Be Tested With Holiday Detector At Contractors Cost And The Contractor Shall Repair All Holidays To The Satisfaction Of Elc At No Extra Cost ( Payment Will Be Made On Finished Area Of Work ) . , Gas Cutting Of M.S. Pipes And / Or M.S. Plates Of Different Thickness All Complete As Per Specification And Direction Of The Engineer-In- Charge.Thikness In Mm 5Mm To 8Mm Thick Plate. , Field Welding Of M.S. Plate By Means Of Electric Arc Welding As Per Relevent Is Specification Using Standard Electrodes Including Edge Preparation And Charges Of Deployment Of Electric Generator Set With Fuel, Lubricant, And All Other Tools And Plants All Complete As Per Specification And Direction Of Engineer-In-Charge. [ Engineer-In-Charge Shall Approve The Electrodes For Arc Welding Before Use ] Throat Thickness In Mm 8Mm , Cast Iron Double Flanged Manually Operated Sluice Valves Generally Conforming To Is 14846 : 2000, Having Four Faces And Spindle Nut Of Gunmetal. Inside Screw Non- Rising Type Quality Gunmetal / Aisi 410 Spindle: Seat Tested To 10Kg / Cm² And Body Tested To 15Kg / Cm², Flanges Flat Faced And Drilled To 1.S.: 1538 : 1993. Painted Black All Over With Asphalt Base Paint. Valves Tested By Closed End Method. Nb Diameter In Mm 100 , 150Mm , 200Mm , Cast Iron Kinetic Double Orifice Type Air Release Valve Having Small Orifice Elastic Ball Resting On Gun Metal Orifice Nipple Large Orifice Vulcanite Ball Seating On Moduled Seat Ring, Valve With Built-In-Kinetic Features, Isolating Sluice Valve Mounted In Horizontal Position And Operated By A Metre Wheel Gearing:Inlet Faced And Drilled To Is 1538 Table 4 & 6. Valve Suitable For Maximum Working Pressure Of 10 Kg / Cm2. Nb Diameter In Mm 80 , 100Mm , 150Mm , Supplying. Fitting And Fixing Air Valve Splash Plate Useing 24 Mm Thick Ms Plate ) According To Necessary Site Measurement As Per Direction Of Eic. , Lowering, Fitting And Fixing Of All Types Of Valves In Proper Position And Alignment Using Chain Pully Block Or Crane ( For Diameter Above 250 Mm ) By Providing Temporary Support, As Required, Gaskets, Nuts & Bolts Etc. All Cornplete As Per Specification And Direction Of The Engineer-In- Charge. [ The Rate Includes Cost Of Flange Joints ] Diameter In Mm 100 , 150Mm , 200Mm , Hydraulically Testing Of C.L. / D.I / A.C Pipe Lines In Sections, Under A Head Of Water Not Less Than 60M { 6Kg / Cm². Pressure ) Or Above As Per Specific Requirements By Filling The Main With Supply Of Water Including Supply Of All Specials And Equipments Like Pump Sets, Gauges, End Caps Blank Flange Etc. All Complete As Per Specification And Direction Of The Engineer-In-Charge. [ After Successful Completion Of Test. Removal Of Ancillary Specials. Equipments. Plugging Arrangements And Disposal Of Water Shall Be Made At No Extra Cost ] Diameter In Mm100 , 150Mm , 200Mm , Shifting House Connection Or Stand Post Connection From Existing Main To New Main After Excavation Through Any Kind Of Soil And Road Materials Up To Required Depth. Dismantling Existing Ferrule With All Fittings. Plugging Hole Of Old Main With G.I. Plug. Drilling And Tapping The New Main. Refixing The Ferrule On The New Main With Serviceable Old G.I Pipes And Other Specials ( New G.L. Pipes And Other Specials. If Required To Be Installed Shall Be Paid Extra ) And Back Filling The Trench With Excavated Materials All Complete As Per Specification And Direction Of The Engineer- In-Charge. , Dewatering By Pumps Including All Leads, Lifts And Making All Arrangements Of Disposal. Where Continuous Flow Of Water From A Source Other Than Natural Or Ground Water Is Encountered In Case Of Emergency Maintenance Works Related To Leakage. Breakage And Making Wet Connections. [ Note ;- In Case Of Any Other Situation Demanding Such Emergency Dewatering. Use Of This Item Is To Be Approved By The Superintending Engineer / Tender Accepting Authority. This Item Shall Be Executed On The Specific Direction Duly Supported By Proper Clarification Of The E.I.C. Who Will Be Satisfied In Absolute Discretion That Such Work Has Not Been Necessitated Due To Any Natural Source Of Water Or Any Fault Of The Contractor ] , Disinfection Of Water Main By Filling With Water Containing Bleaching Powder Of Sufficient Quantity Capable Of Maintaining A Residual Chlorine Concentration Of 10Mg / L Within The Main After A Detention Period Of Two Hours And Flushing The Same With Fresh Water All Complete As Per Specification And Direction Of The Engineer-In- Charge. [ After Successful Completion Of The Process, Disposal Of Water And Bacteriological Testing Of Sample Of Flushed Out Water From The Mains Should Be Made At No Extra Cost ] Diameter In Mm100 , 150Mm , 200Mm , Supplying, Fitting And Fixing G.I. Pipes Of Tata Make With All Necessary Accessories, Specials Viz. Socket, Bend, Tee, Union, Cross, Elbo, Nipple, Longscrew, Reducing Socket, Reducing Tee, Short Piece Etc. Fitted With Holder Bats Clamps, Including Cutting Pipes, Making Threads, Fitting, Fixing Etc. Complete In All Respect Including Cost Of All Necessary Fittings As Required, Jointing Materials And Two Coats Of Painting With Approved Paint In Any Position Above Ground. ( Payment Will Be Made On The Centre Line Measurements Of Total Pipe Line Including All Specials. No Separate Payment Will Be Made For Accesories, Specials. Payment For Painting Will Be Made Seperately ) ( I ) 15 Mm Dia. Medium Quality , ( Ii ) 20 Mm Dia. Medium Quality , Add 12% Gst , L.W.Cess 1%

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 28-04-2022 Date Extended Date 03-05-2022

Key Value

Document Fees
Refer document
Tender Value
INR 44.96 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail