Maintenance Of Internal Electrification, Light Fittings / Fixtures / Accessories At Omqs, Smqs And Otm Billets At Outer And Inner Pockets Of Domestic Area Of 32 Wing Under Age E / M, Ge ( Af ) No 2 Jodhpur, jodhpur-Rajasthan

Military Engineer Services-MES has published Maintenance Of Internal Electrification, Light Fittings / Fixtures / Accessories At Omqs, Smqs And Otm Billets At Outer And Inner Pockets Of Domestic Area Of 32 Wing Under Age E / M, Ge ( Af ) No 2 Jodhpur. Submission Date for this Tender is 02-05-2022. Electrification Work Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

31741344
Corrigendum : Maintenance Of Internal Electrification, Light Fittings / Fixtures / Accessories At Omqs, Smqs And Otm Billets At Outer And Inner Pockets Of Domestic Area Of 32 Wing Under Age E / M, Ge ( Af ) No 2 Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
02-05-2022

Tender Details

Maintenance Of Internal Electrification, Light Fittings / Fixtures / Accessories At Omqs, Smqs And Otm Billets At Outer And Inner Pockets Of Domestic Area Of 32 Wing Under Age E / M, Ge ( Af ) No 2 Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Apr-2022 Revised_BoQ BOQ 25-04-2022
2 25-Apr-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-05-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work:Maintenance of internal electrification, light fittings/fixtures/accessories at OMQs, SMQs and OTM Billets at outer and inner pockets of domestic area of 32 Wing under AGE E/M of GE(AF) No.02 Jodhpur
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,.
2M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : -
3(a)One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
4(b)One light point controlled by two No’s 5 Amps switch two way
5(c)One 3 pin 5 Amp switch & socket outlet on same board with other switches.
6(d)One 3 pin 5 Amp switch & socket outlet on Independent board.
7(e)One bell point controlled by one switch 5 Amps bell push.
8All same as per item ser No 2 here-in-above but wiring using 2.5 sq mm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independent board.
9S&F(in repairs) Switch piano, flush type, single pole, one way, 6 Amp.
10S&F(in repairs) Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
11S&F(in repairs) Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
12S&F(in repairs) Ceiling rose surface Bakelite 65x50mm three terminal.
13S&F(in repairs) Lamp holder insulated PVC/Polycarbonate/ Bakelite body, fixed on PVC round or square box using necessary screw & gutty complete allas specified.
14S&F(in repairs) Stepped type electronic fan regulator, socket size, flush type 230V AC.
15S&F(in repairs) Stepped type electronic fan regulator, switch size, flush type 230V AC.
16S&F(in repairs) electronic Bell Bulbul music, 230 volt, single phase.
17S&F(in repairs) switch modular single pole one way 6 Amps 230 volt 1 module.
18S&F(in repairs) switch modular single pole two way 6 Amps 230 volt 1 module.
19S&F(in repairs) bell push, Modular type, 6 Amps, 2 Module
20S&F(in repairs) switch modular single pole one way 16 Amps 230 volt 1 module.
21S&F(in repairs) Socket modular 6 Amp 2/3 pin combined two module.
22S&F(in repairs) Socket modular 6&16 Amp 2/3 pin combined two module.
23S&F(in repairs) electronic fan regulator modular stepped type 120 watt, two module.
24S&F(in repairs) modular white or Ivory cover plate with frame 1 module
25S&F(in repairs) modular white or Ivory cover plate with frame 2 module
26S&F(in repairs) modular white or Ivory cover plate with frame 3 module
27S&F(in repairs) modular white or Ivory cover plate with frame 4 module
28S&F(in repairs) modular white or Ivory cover plate with frame 6 module
29S&F(in repairs) modular white or Ivory cover plate with frame 8 module
30S&F(in repairs) modular white or Ivory cover plate with frame 12 module
31Supply and fix in repairs fan capacitor 2.5 Mfd suitable for 1200mm sweep ceiling fan,
32Supply and fix in repairs 3 Pin Plug Top 16 Amps, 240 volt insulated bakelite body(Ivory/White)
33Fixing only LED light fitting any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Note :Serviceable light fittings or new light fitting will be issued by department free for fixing only with proper issue vouchers at AGE E/M Store yard.
34Fixing only Electric energy kWH meter Single phase/three phase 10 to 60 Amps, including making connection of incoming and outgoing wiring circuits using single core PVC insulated copper multistranded cable of size 6.0 sq mm and necessary lugs, including submission of kWH reading details of old unserviceable taken down meter and new installed meter to AGE E/M all as specified and directed. Note :Serviceable meters or New electric Meters will be issued free for fixing only with proper issue vouchers at AGE E/M store yard.
35Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unscrewing from position, dismantling blades and removing fan and blade to E/M Store yard all as directed and specified.
36Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Serviceable fan/new fans will be supplied by department free for fixing only with proper issue vouchers with proper issue vouchers at AGE E/M store yard.
37Fixing only exhaust fan 300/450mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 No’s 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Serviceable fan/new fans will be supplied by department free for fixing only with proper issue vouchers at AGE E/M store yard
38Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
39M&L for MCB SPN 32Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
40M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
41M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
42Supply and replace Sheet metal enclosure SPN DBs, 2 way without bus bar completeincluding taking out old all as specified and directed.
43Supply and fix in repairs metal clad, 2 Pin+Earth Plug Top 16 Amps, 240 volt.
44Taking down carefully unserviceable storage type water heaters (Geysers) 25/50 Ltr Capacity and shifting the same to for repairs works or shifting to MES E/M store yard for safe custody all as directed.
45Installation only Electric Storage type water heater (Geysers) 25/50 Ltr capacity with standard fixing accessories including suitable size wall fastener bolts & Nuts, gutties etc complete all as specified and directed. NOTE: Serviceable/new geysers will be supplied by department free for fixing only with proper issue vouchers at AGE E/M store yard.
46M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 450mm long complete all as directed
47M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 750mm longcomplete all as directed
48M&L for replacement of thread type B-17 base LED lamps Warm light 3 to 6 watt of decorative light fittings at VIP guest rooms of Officers Mess complete all as directed
49M&L for replacement of unserviceable LED driver suitable for 2 feet x 2 feet recessed/surface mounting type LED light fittings as per make of existing light fittings complete all as directed.
50Taking out existing unserviceable switch board plates any type, dismantling switches casually, stacking at site for use of serviceable switches and supply and fixing new 3mm thick Masonite laminated sheet top cover fixed on 6/8 inch x 10 inch MS box and brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with1.5 sq mm single core copper multistranded cable all as directed at site by Engineer-in-charge. Note :New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items. Note :New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items.
51All as per item ser No 45 here-in-before but new 3mm thick Masonite laminated sheet top cover white or ivory fixed on 6/8 inch x 4 inch MS box. complete all as directed
52All as per item ser No 45 here-in-before but new 3mm thick Masonite laminated sheet top cover white or ivory fixed on 4 inch x 4 inch MS box. complete all as directed
53Note for Item No 9.0 to 47.0 :- (a)The contractor will deploy sufficient resources for completion of day to day complaint within 24 Hrs from the time of reporting.Any delay beyond above mentioned time limit suitable penalties as mentioned in relevant clause of Contract. Or otherwise R s 150 per non complain attending will be recovered from thir due amount .Weakly report of complain received and attend by the contractor will be deposit by the contractor in GE’S OFFICE for record and payment purpose. (b)A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consultation with Engr-in-Charge or JE detailed by him. (c)The contractor will make suitable arrangement for emergent complaints and will notify JE/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard. (d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e)The quoted rated deems to be inclusive of transportation, T&P and other expenses required for the resource deployment at the complaint site around scattered at AF Station Jodhpur. (f) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically by Engr-in-charge or JE detailed by him to streamline complaints disposal system. Record of Complain received and attend be submitted duly signed by eng-in charge and users, for allowing payment in each RAR\BILL .
54Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion completeincluding taking out old all as directed.
55Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion completeincluding taking out old all as directed.
56Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion completeincluding taking out old all as directed.
57Supply and replace Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs and including provision for fixing TPN MCB as incomer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification completeincluding taking out old all as specified all as specified and directed. Note : MCB SP/SPN/TPN will measured and paid separately under relevant item.
58Supply and replace distribution boardTPN DB with protection IP-43 and provision for fixing 100A MCCB, 16kA 3/4 pole as incomer and SP/TP MCB as outgoing 6 way fixed flush or in wall surface and making good damaged surface of wall to match with its existing specification including taking out old MCB DB. Note : MCCB will measured and paid separately under relevant item.
59Taking down carefully light fitting any type from surface/recessed/wall mounting type stacking at site for re-use or shifting unserviceable lights to store for taking credit all as directed and specified.
60Supply and fixing (in repairs) compact commercial LED Tube light batten suitable for T8 LED tube rod, batten fixed using 2 Nos round or square box PVC heavy duty, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed and specified.
61Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases ofsuitable size complete all as directed and specified.
62S&F LED light fitting 1 x 10W bulkhead luminaires including LED light driver perfect interior and exterior application connecting up with three core flexible copper conductor cable of suitable size complete all as directed and specified
63Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light (Day cool/warm light) complete with drivers, holders, LED lamp suitable for roof ceiling (cut-out size 80mm and surface dia 115mm approx.) including connecting up with three core flexible copper conductor cable of suitable size complete all as directed and specified.
64Supply and fixing round/square shape 10 watt 220 volts AC Surface mounting type with high efficiency PMMA diffuser soft glare free light(day cool/warm light) complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed and specified
65S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED,complete pre-wired, incl suitable bracket for fixing light on wall or any indicated location all as specified and as directed by Engr - in Charge
66M&L for taking out old unserviceable lovers shutters of exhaust fans from external face of walls from double/triple storey buildings and providing aluminium wire mesh (3 to 4 mm mesh) with Aluminium frame (Gauge thickness not less than 1.2mm) including necessary fixing accessories (likeclamps, screws, washers, gutties etc) to prevent entry of birds/insects through opening of exhaust fans on walls. Approximate size of frame to be provided at site is 400mm x 400mm for 300mm dia openings holes and 600mm x 600mm for 450mm dia openings holes. Note : Necessary T&P such as ladders, safety belts, drilling equipment’s for fixing Wire mesh at heights of double/triple storey building shall be arranged by the contractor and cost for the same deems to be included in quoted rates.
67S&F ceiling fan of 1200 mm sweep, induction motor type, BEE approved, single phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 M fd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable from ceiling rose or connector to fan including marking of MES numbercomplete all as specified.NOTE: The length of suspension rod shall be as per site requirement.
68S&F Exhaust fan 300 mm sweep, metal body, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified.
69S&F Exhaust fan 450 mm sweep, metal body, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified.
70Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm all as directed and specified
71Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm all as directed and specified
72Supply & connect PVC flat twin core cable, black sheathed, stranded aluminium conductor 4.0 Sq mm complete all as specified and directed.
73Supply & connect PVC flat twin core cable, black sheathed, stranded aluminium conductor 6.0 Sq mm complete all as specified and directed.
74Supply & connect PVC flat twin core cable, black sheathed, stranded aluminium conductor 10.0 Sq mm complete all as specified and directed.
75M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulatedflexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc) including taking down old unserviceablesub main wiring complete all as specified for following sizes of wires :-. (Note : GI saddle shall be used to fix PVC conduit and distance between two saddle shall not be exceed 1.2 mtr)
76(a)Two runs of 2.5 Sq.mm main cable along with one run of single core 2.5 Sq.mm for continuous earth wire
77(b)Two runs of 4.0 Sq.mm main cable along with one run of single core 4.0 Sq.mm for continuous earth wire
78(c) Two runs of 6.0 Sq.mm main cable along with one run of single core 6.0 Sq.mm for continuous earth wire
79(d)Two runs of 10.0 Sq.mm main cable along with one run of single core 10.0 Sq.mm for continuous earth wire