Construction Of Re-Circulatory Aqua Culture System Including Aquaponics Culture At Bihpuria And Barbali Gp
Tender Value
1.08 Crore
Estimated cost
Bid Submission
09 Apr 2022
0 days left
EMD
2.16 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
bihpuria → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Re-Circulatory Aqua Culture System Including Aquaponics Culture At Bihpuria And Barbali Gp
BOQ
| Sl. No. | Item Description |
| 1 | CONSTRUCTION OF RAS CIRCULATORY MASONRY WITH PLINTH AT BORBALI GP |
| 2 | Eartthwork in excavation for foundation trenchs of walls , retaining walls, footings of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling dresssing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified.A) up to a depth of 2.00 m below the existing ground level. b) in hard/dense soil plinth wall |
| 3 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:5 |
| 4 | Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may be necesssary . C) with river sand or slit by truck carriage including loadibng and unloading. |
| 5 | Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor. |
| 6 | Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on float soling circullar tank bottom. |
| 7 | RCC 1:1.5:3 in super structure Providing and layong plain reinforced cement concrete works, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work by using machine mixure . A) in substructure up to plinth level Foundation , footing, columns with base tie and plinth beam pile cap base slab, retaining walls, walls of septick tank, inspaction pit and the like and other works not less than 100mm thick up to plinth level without using admixture, plasticiser m20 grade concrete or prop 1:1.5:3 RCC work at circular floor |
| 8 | Brick work incent morter with 1st class brick including racking out joints and curing complete as directed. Ii) In superstucture above plinth level up to 1st floor level. In proportion 1:5 brick work in walls |
| 9 | Supplying fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. Work /RB Walling including straightening , cleaning , cutting and bending to proper shaps and length as per details , supplying and binding with 20G annealed blck wire and pleacing in position with proper blocks, supports, chairs spacers etc. complete. other ISI approved TMT reinforcement bar. |
| 10 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 11 | Applying epoxy coating waterproffing the tanks. Applying one coat of epoxy coating techoxy of choksey chemicals followed by two coats of polyurethane waterprof coating techcoat 61P at an interval of 12 hours each for waterproofing of external walls, roofs, terraces, chajjas etc. as specified & dierected by the Department complete. area as per above. |
| 12 | INSTALLATION OF PLUMBING NETWORK |
| 13 | Supplying fitting and fixing Pipe with all necessary fittings in exposed or in trenches including tranching and refilling the same etc. Complete as directed. B. uPVC pipe fittings(Using uPVC high preasure pipe) using SUPREME/PRINCE/SFMC/FUSION brand pipe |
| 14 | Supplying fitting and fixing PVC pipes of 6kg/cm2 or other ISI approved including joining, fitting and fixing with clamps etc as necessary complete at all levels including below G.L as directedand specified. A. In exposed surface or in trenches. II. 110mm dia. 110mm dia pvc pipes from bottom centre of circullarpools and cornel type drain pipe carrying containment water to mechanical filter through pump/garvity flow. |
| 15 | 160mm dia PVC pipes connecting above 8 pipes with the drum filter |
| 16 | 50mm dia pvc at bottom of MBBR for areation |
| 17 | Provission of valve to control the bottom central outlet of each tank 110mm dia ball valve uPVC heavy duty |
| 18 | INSTALLATION OF DRUM FILTER TANK AND DRUM FILLTER |
| 19 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2mm below the existing ground level with hard soil. |
| 20 | Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on flat soling |
| 21 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 22 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 23 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 24 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 25 | Cost of Drum Filter SS with all accessories etc. |
| 26 | INSTALLATION OF BIO FILTER (MBBR) TANK( INNER SIZE 5MX2MXDEPTH 2M) |
| 27 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation |
| 28 | Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) br |
| 29 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 30 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 31 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 32 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 33 | Cost of Bio Filter Media balls |
| 34 | INSTALLATION OF UV TREATMENT TANK(SIZE 1.5MX2.0MXDEPTH 0.7M) |
| 35 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation |
| 36 | Providingsoling in foundation and under floor wityh stone/best quality picked jhama brics, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materils and if necessary dewatering, complete. Brick soling |
| 37 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 38 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 39 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 40 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 41 | Cost of UV machine 330W |
| 42 | SUMP[ FOR STORAGE OF STERILISED WATER AND INSTALLATION OF PREATURE/AXIAL PUMPS AND SUMP(SIZE 2MX5.0XDEPTH 2M) |
| 43 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2.00m below the existing ground level. |
| 44 | providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. |
| 45 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 46 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 47 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 48 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 49 | Supply & Installation of one 3000LPM axail pumps to pump filtered water to tanks with all fittings. |
| 50 | Installation of one 3HP root blower(central air blower) with all necessary piping works etc. Supply air to eight circular tanks and MBBR bottom. |
| 51 | INSTALLATION OF ELECTRICAL WORKS |
| 52 | Wiring for light/fan/ call bell point with 2x1.5sqmm PVC insulted single core unsheathed industrial cable FR conforming to IS-694: 1990 with flexible bright anneled electrolycticcopper conductor for voltage grade up to 110 volts with flat 19mm ISI marked casing N capping in surface system, including 6AMP flush type switch bell push GI/ MS switch boardhalf connel on wall with phanolic laminated sheet cover, celing rose etc. completed as directed and specified by the deptt. |
| 53 | Wiring for drawing sub main line with PVC insulted single core unsheatheled industrial cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surfance flatt ISI marked cassing n capping system includdingh earth continiuty. with 2x 6 sqmm + earth continuty with 1x4sqmm cable in flat 25mm ISI marked casing n capping system |
| 54 | Wiring for 5/6 inch 16 AMPS power plugg point with 4 sqmm PVC insulted single core unshetheled industrial cablke FR conforming to IS-694:1990 with flexible bright annealed electrolyctic copper conducvtor for voltage grade up to 1100volts with flat 19mm ISi marked cassing n capping in surfence system, including providing and fixing 5/6 pin 16 AMPS flush type shocket outlet and 16 AMPS flush type switch , GI, MS switch board with phenolic laminated sheet cover earth continuty with 2.5sqmm cable to the 3rd pin of the socket as required complete. long point up to 10.00 m length. |
| 55 | Supply and installatioon & commissiong of readymade maintanence free CPRI approved chemical earthing system with 80mm dia. 2.00 m lenghth corrsion free dual pipe technology GI CHEMRODE ELECTRODE complete with RESLOW grounding minearals including excavation of earth pit in rtghe construction brick earth chember including plastering both inner & ouetr surface of brick wall as specified and directed by the department |
| 56 | supplying fixing ICTP and n ling man switch ewire able fuses of 500 volte grade including drilling boards/iron framesand fixing with bolts and nuts connection as approved by the Deptt. complete as required |
| 57 | supplying with fitting and fixing sheet steel, phosphatised, powder painted single door surface amounting MCB enclouse incorporated with bas-bar, neutral link earth bar and din rail etc fitted on wall with grounting nuts & bolts as reqd. Comp[lete with making necessary connection as approved specified and directed by the deptt. |
| 58 | Strip[ite lumineries complete with VPIT copper ballast/ electronoic ballast and decorative end cap and 1x36/40 watt fluorescent tube model-DSG114LDBCROMGOLD/DSG11114LBDN CROM GOLD NEW / DSG1314EB CG GOLD?DSG 1414EB PLANET GOLD with super saver/ super brite lamp or equivilent PHILIPS/Wipro?BAJAJ/HEAVELS make |
| 59 | CONSTRUCTION OF SHED OVER THE RAS |
| 60 | Providing fitting hoisting and fixing of roof trusses including Purlins fabricated using MS Circullar hollow section conforming to relevent IS code as per approved design and drawings including providing MS cleats base plates, bolts and nuts and one coal of red oxide Zinc chormate primer and two coats of approved enamel paints complete including fittingnecessary |
| 61 | PCC embedding for ms tube post for holding roof truss plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps,walls,brick works etc. As directed and specified including dewatering if necessary and curing complete in prop[ cement 3 sand 6 coarse aggregarte by volume |
| 62 | Providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed |
| 63 | Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin etc. |
| 64 | ESTIMATE OF CONSTRUCTION OF OFFICE |
| 65 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation |
| 66 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 67 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 68 | ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm |
| 69 | Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed in substucture in proportion 1:5 |
| 70 | 1st class brick nogged wall in cement including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level |
| 71 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 72 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 73 | ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm |
| 74 | supplying fitting and fixing cemented gnil as ventilator |
| 75 | Providing undresssed wood work in roof truss raftarrs purlins tie and the like including hoisting and fixing in position with necessary spikes nalls including MS strapa, seconed class timber. |
| 76 | Providing wooden in frame of doors, windows, clerestory windows and other similar works wrought framed and fixed in position in contact with CC bank massory walls including supplying fitting with ms flat hold last as per design and embeded in cement concrete block in prop 1:2:4 and with two coated of kincade oiling to the timber . 2nd class timber . |
| 77 | Providing fiting and 1st class local wood battened framed and braced door shutters including oxidizied ms butt hings 6nos with necessary wood screws |
| 78 | Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin et |
| 79 | providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed |
| 80 | Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may |
| 81 | Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor. |
| 82 | Miscelelaneous including sanitation and unforseen expenditure etc. |
| 83 | Aquaponics culture |
| 84 | Contingency including signboard |
| 85 | CONSTRUCTION OF RAS CIRCULATORY MASONRY WITH PLINTH AT BIHPURIA GP |
| 86 | Eartthwork in excavation for foundation trenchs of walls , retaining walls, footings of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling dresssing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified.A) up to a depth of 2.00 m below the existing ground level. b) in hard/dense soil plinth wall |
| 87 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:5 |
| 88 | Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may be necesssary . C) with river sand or slit by truck carriage including loadibng and unloading. |
| 89 | Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor. |
| 90 | Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on float soling circullar tank bottom. |
| 91 | RCC 1:1.5:3 in super structure Providing and layong plain reinforced cement concrete works, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work by using machine mixure . A) in substructure up to plinth level Foundation , footing, columns with base tie and plinth beam pile cap base slab, retaining walls, walls of septick tank, inspaction pit and the like and other works not less than 100mm thick up to plinth level without using admixture, plasticiser m20 grade concrete or prop 1:1.5:3 RCC work at circular floor |
| 92 | Brick work incent morter with 1st class brick including racking out joints and curing complete as directed. Ii) In superstucture above plinth level up to 1st floor level. In proportion 1:5 brick work in walls |
| 93 | Supplying fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. Work /RB Walling including straightening , cleaning , cutting and bending to proper shaps and length as per details , supplying and binding with 20G annealed blck wire and pleacing in position with proper blocks, supports, chairs spacers etc. complete. other ISI approved TMT reinforcement bar. |
| 94 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 95 | Applying epoxy coating waterproffing the tanks. Applying one coat of epoxy coating techoxy of choksey chemicals followed by two coats of polyurethane waterprof coating techcoat 61P at an interval of 12 hours each for waterproofing of external walls, roofs, terraces, chajjas etc. as specified & dierected by the Department complete. area as per above. |
| 96 | INSTALLATION OF PLUMBING NETWORK |
| 97 | Supplying fitting and fixing Pipe with all necessary fittings in exposed or in trenches including tranching and refilling the same etc. Complete as directed. B. uPVC pipe fittings(Using uPVC high preasure pipe) using SUPREME/PRINCE/SFMC/FUSION brand pipe |
| 98 | Supplying fitting and fixing PVC pipes of 6kg/cm2 or other ISI approved including joining, fitting and fixing with clamps etc as necessary complete at all levels including below G.L as directedand specified. A. In exposed surface or in trenches. II. 110mm dia. 110mm dia pvc pipes from bottom centre of circullarpools and cornel type drain pipe carrying containment water to mechanical filter through pump/garvity flow. |
| 99 | 160mm dia PVC pipes connecting above 8 pipes with the drum filter |
| 100 | 50mm dia pvc at bottom of MBBR for areation |
| 101 | Provission of valve to control the bottom central outlet of each tank 110mm dia ball valve uPVC heavy duty |
| 102 | INSTALLATION OF DRUM FILTER TANK AND DRUM FILLTER |
| 103 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2mm below the existing ground level with hard soil. |
| 104 | Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on flat soling |
| 105 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 106 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 107 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 108 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 109 | Cost of Drum Filter SS with all accessories etc. |
| 110 | INSTALLATION OF BIO FILTER (MBBR) TANK( INNER SIZE 5MX2MXDEPTH 2M) |
| 111 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation |
| 112 | Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) br |
| 113 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 114 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 115 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 116 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 117 | Cost of Bio Filter Media balls |
| 118 | INSTALLATION OF UV TREATMENT TANK(SIZE 1.5MX2.0MXDEPTH 0.7M) |
| 119 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation |
| 120 | Providingsoling in foundation and under floor wityh stone/best quality picked jhama brics, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materils and if necessary dewatering, complete. Brick soling |
| 121 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 122 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 123 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 124 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 125 | Cost of UV machine 330W |
| 126 | SUMP[ FOR STORAGE OF STERILISED WATER AND INSTALLATION OF PREATURE/AXIAL PUMPS AND SUMP(SIZE 2MX5.0XDEPTH 2M) |
| 127 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2.00m below the existing ground level. |
| 128 | providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. |
| 129 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 130 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 131 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4 |
| 132 | Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick. |
| 133 | Supply & Installation of one 3000LPM axail pumps to pump filtered water to tanks with all fittings. |
| 134 | Installation of one 3HP root blower(central air blower) with all necessary piping works etc. Supply air to eight circular tanks and MBBR bottom. |
| 135 | INSTALLATION OF ELECTRICAL WORKS |
| 136 | Wiring for light/fan/ call bell point with 2x1.5sqmm PVC insulted single core unsheathed industrial cable FR conforming to IS-694: 1990 with flexible bright anneled electrolycticcopper conductor for voltage grade up to 110 volts with flat 19mm ISI marked casing N capping in surface system, including 6AMP flush type switch bell push GI/ MS switch boardhalf connel on wall with phanolic laminated sheet cover, celing rose etc. completed as directed and specified by the deptt. |
| 137 | Wiring for drawing sub main line with PVC insulted single core unsheatheled industrial cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surfance flatt ISI marked cassing n capping system includdingh earth continiuty. with 2x 6 sqmm + earth continuty with 1x4sqmm cable in flat 25mm ISI marked casing n capping system |
| 138 | Wiring for 5/6 inch 16 AMPS power plugg point with 4 sqmm PVC insulted single core unshetheled industrial cablke FR conforming to IS-694:1990 with flexible bright annealed electrolyctic copper conducvtor for voltage grade up to 1100volts with flat 19mm ISi marked cassing n capping in surfence system, including providing and fixing 5/6 pin 16 AMPS flush type shocket outlet and 16 AMPS flush type switch , GI, MS switch board with phenolic laminated sheet cover earth continuty with 2.5sqmm cable to the 3rd pin of the socket as required complete. long point up to 10.00 m length. |
| 139 | Supply and installatioon & commissiong of readymade maintanence free CPRI approved chemical earthing system with 80mm dia. 2.00 m lenghth corrsion free dual pipe technology GI CHEMRODE ELECTRODE complete with RESLOW grounding minearals including excavation of earth pit in rtghe construction brick earth chember including plastering both inner & ouetr surface of brick wall as specified and directed by the department |
| 140 | supplying fixing ICTP and n ling man switch ewire able fuses of 500 volte grade including drilling boards/iron framesand fixing with bolts and nuts connection as approved by the Deptt. complete as required |
| 141 | supplying with fitting and fixing sheet steel, phosphatised, powder painted single door surface amounting MCB enclouse incorporated with bas-bar, neutral link earth bar and din rail etc fitted on wall with grounting nuts & bolts as reqd. Comp[lete with making necessary connection as approved specified and directed by the deptt. |
| 142 | Strip[ite lumineries complete with VPIT copper ballast/ electronoic ballast and decorative end cap and 1x36/40 watt fluorescent tube model-DSG114LDBCROMGOLD/DSG11114LBDN CROM GOLD NEW / DSG1314EB CG GOLD?DSG 1414EB PLANET GOLD with super saver/ super brite lamp or equivilent PHILIPS/Wipro?BAJAJ/HEAVELS make |
| 143 | CONSTRUCTION OF SHED OVER THE RAS |
| 144 | Providing fitting hoisting and fixing of roof trusses including Purlins fabricated using MS Circullar hollow section conforming to relevent IS code as per approved design and drawings including providing MS cleats base plates, bolts and nuts and one coal of red oxide Zinc chormate primer and two coats of approved enamel paints complete including fittingnecessary |
| 145 | PCC embedding for ms tube post for holding roof truss plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps,walls,brick works etc. As directed and specified including dewatering if necessary and curing complete in prop[ cement 3 sand 6 coarse aggregarte by volume |
| 146 | Providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed |
| 147 | Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin etc. |
| 148 | ESTIMATE OF CONSTRUCTION OF OFFICE |
| 149 | Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation |
| 150 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 151 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 152 | ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm |
| 153 | Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed in substucture in proportion 1:5 |
| 154 | 1st class brick nogged wall in cement including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level |
| 155 | Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor. |
| 156 | Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete |
| 157 | ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm |
| 158 | supplying fitting and fixing cemented gnil as ventilator |
| 159 | Providing undresssed wood work in roof truss raftarrs purlins tie and the like including hoisting and fixing in position with necessary spikes nalls including MS strapa, seconed class timber. |
| 160 | Providing wooden in frame of doors, windows, clerestory windows and other similar works wrought framed and fixed in position in contact with CC bank massory walls including supplying fitting with ms flat hold last as per design and embeded in cement concrete block in prop 1:2:4 and with two coated of kincade oiling to the timber . 2nd class timber . |
| 161 | Providing fiting and 1st class local wood battened framed and braced door shutters including oxidizied ms butt hings 6nos with necessary wood screws |
| 162 | Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin et |
| 163 | providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed |
| 164 | Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may |
| 165 | Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor. |
| 166 | Miscelelaneous including sanitation and unforseen expenditure etc. |
| 167 | Aquaponics culture |
| 168 | Contingency including signboard |
AI Tender Summary
Tender Timeline
Apr 04, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedApr 09, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedApr 11, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender