Public Administrative Department Local Bodies Closing in 0 days TDR #31714728

Construction Of Re-Circulatory Aqua Culture System Including Aquaponics Culture At Bihpuria And Barbali Gp

Issued by Local Bodies · bihpuria, Assam
Tender Value
1.08 Crore
Estimated cost
Bid Submission
09 Apr 2022
0 days left
EMD
2.16 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bihpuria → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Re-Circulatory Aqua Culture System Including Aquaponics Culture At Bihpuria And Barbali Gp

BOQ

Name of Work: CONSTRUCTION OF RE-CIRCULATORY AQUACULTURE SYSTEM AT BARBALI AND BIHPURIA GP INCLUDING AQUAPONICS
Sl. No. Item Description
1CONSTRUCTION OF RAS CIRCULATORY MASONRY WITH PLINTH AT BORBALI GP
2Eartthwork in excavation for foundation trenchs of walls , retaining walls, footings of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling dresssing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified.A) up to a depth of 2.00 m below the existing ground level. b) in hard/dense soil plinth wall
3Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:5
4Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may be necesssary . C) with river sand or slit by truck carriage including loadibng and unloading.
5Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor.
6Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on float soling circullar tank bottom.
7RCC 1:1.5:3 in super structure Providing and layong plain reinforced cement concrete works, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work by using machine mixure . A) in substructure up to plinth level Foundation , footing, columns with base tie and plinth beam pile cap base slab, retaining walls, walls of septick tank, inspaction pit and the like and other works not less than 100mm thick up to plinth level without using admixture, plasticiser m20 grade concrete or prop 1:1.5:3 RCC work at circular floor
8Brick work incent morter with 1st class brick including racking out joints and curing complete as directed. Ii) In superstucture above plinth level up to 1st floor level. In proportion 1:5 brick work in walls
9Supplying fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. Work /RB Walling including straightening , cleaning , cutting and bending to proper shaps and length as per details , supplying and binding with 20G annealed blck wire and pleacing in position with proper blocks, supports, chairs spacers etc. complete. other ISI approved TMT reinforcement bar.
10Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
11Applying epoxy coating waterproffing the tanks. Applying one coat of epoxy coating techoxy of choksey chemicals followed by two coats of polyurethane waterprof coating techcoat 61P at an interval of 12 hours each for waterproofing of external walls, roofs, terraces, chajjas etc. as specified & dierected by the Department complete. area as per above.
12INSTALLATION OF PLUMBING NETWORK
13Supplying fitting and fixing Pipe with all necessary fittings in exposed or in trenches including tranching and refilling the same etc. Complete as directed. B. uPVC pipe fittings(Using uPVC high preasure pipe) using SUPREME/PRINCE/SFMC/FUSION brand pipe
14Supplying fitting and fixing PVC pipes of 6kg/cm2 or other ISI approved including joining, fitting and fixing with clamps etc as necessary complete at all levels including below G.L as directedand specified. A. In exposed surface or in trenches. II. 110mm dia. 110mm dia pvc pipes from bottom centre of circullarpools and cornel type drain pipe carrying containment water to mechanical filter through pump/garvity flow.
15160mm dia PVC pipes connecting above 8 pipes with the drum filter
1650mm dia pvc at bottom of MBBR for areation
17Provission of valve to control the bottom central outlet of each tank 110mm dia ball valve uPVC heavy duty
18INSTALLATION OF DRUM FILTER TANK AND DRUM FILLTER
19Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2mm below the existing ground level with hard soil.
20Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on flat soling
21Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
22Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
23Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
24Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
25Cost of Drum Filter SS with all accessories etc.
26INSTALLATION OF BIO FILTER (MBBR) TANK( INNER SIZE 5MX2MXDEPTH 2M)
27Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation
28Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) br
29Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
30Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
31Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
32Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
33Cost of Bio Filter Media balls
34INSTALLATION OF UV TREATMENT TANK(SIZE 1.5MX2.0MXDEPTH 0.7M)
35Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation
36Providingsoling in foundation and under floor wityh stone/best quality picked jhama brics, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materils and if necessary dewatering, complete. Brick soling
37Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
38Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
39Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
40Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
41Cost of UV machine 330W
42SUMP[ FOR STORAGE OF STERILISED WATER AND INSTALLATION OF PREATURE/AXIAL PUMPS AND SUMP(SIZE 2MX5.0XDEPTH 2M)
43Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2.00m below the existing ground level.
44providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
45Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
46Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
47Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
48Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
49Supply & Installation of one 3000LPM axail pumps to pump filtered water to tanks with all fittings.
50Installation of one 3HP root blower(central air blower) with all necessary piping works etc. Supply air to eight circular tanks and MBBR bottom.
51INSTALLATION OF ELECTRICAL WORKS
52Wiring for light/fan/ call bell point with 2x1.5sqmm PVC insulted single core unsheathed industrial cable FR conforming to IS-694: 1990 with flexible bright anneled electrolycticcopper conductor for voltage grade up to 110 volts with flat 19mm ISI marked casing N capping in surface system, including 6AMP flush type switch bell push GI/ MS switch boardhalf connel on wall with phanolic laminated sheet cover, celing rose etc. completed as directed and specified by the deptt.
53Wiring for drawing sub main line with PVC insulted single core unsheatheled industrial cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surfance flatt ISI marked cassing n capping system includdingh earth continiuty. with 2x 6 sqmm + earth continuty with 1x4sqmm cable in flat 25mm ISI marked casing n capping system
54Wiring for 5/6 inch 16 AMPS power plugg point with 4 sqmm PVC insulted single core unshetheled industrial cablke FR conforming to IS-694:1990 with flexible bright annealed electrolyctic copper conducvtor for voltage grade up to 1100volts with flat 19mm ISi marked cassing n capping in surfence system, including providing and fixing 5/6 pin 16 AMPS flush type shocket outlet and 16 AMPS flush type switch , GI, MS switch board with phenolic laminated sheet cover earth continuty with 2.5sqmm cable to the 3rd pin of the socket as required complete. long point up to 10.00 m length.
55Supply and installatioon & commissiong of readymade maintanence free CPRI approved chemical earthing system with 80mm dia. 2.00 m lenghth corrsion free dual pipe technology GI CHEMRODE ELECTRODE complete with RESLOW grounding minearals including excavation of earth pit in rtghe construction brick earth chember including plastering both inner & ouetr surface of brick wall as specified and directed by the department
56supplying fixing ICTP and n ling man switch ewire able fuses of 500 volte grade including drilling boards/iron framesand fixing with bolts and nuts connection as approved by the Deptt. complete as required
57supplying with fitting and fixing sheet steel, phosphatised, powder painted single door surface amounting MCB enclouse incorporated with bas-bar, neutral link earth bar and din rail etc fitted on wall with grounting nuts & bolts as reqd. Comp[lete with making necessary connection as approved specified and directed by the deptt.
58Strip[ite lumineries complete with VPIT copper ballast/ electronoic ballast and decorative end cap and 1x36/40 watt fluorescent tube model-DSG114LDBCROMGOLD/DSG11114LBDN CROM GOLD NEW / DSG1314EB CG GOLD?DSG 1414EB PLANET GOLD with super saver/ super brite lamp or equivilent PHILIPS/Wipro?BAJAJ/HEAVELS make
59CONSTRUCTION OF SHED OVER THE RAS
60Providing fitting hoisting and fixing of roof trusses including Purlins fabricated using MS Circullar hollow section conforming to relevent IS code as per approved design and drawings including providing MS cleats base plates, bolts and nuts and one coal of red oxide Zinc chormate primer and two coats of approved enamel paints complete including fittingnecessary
61PCC embedding for ms tube post for holding roof truss plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps,walls,brick works etc. As directed and specified including dewatering if necessary and curing complete in prop[ cement 3 sand 6 coarse aggregarte by volume
62Providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed
63Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin etc.
64ESTIMATE OF CONSTRUCTION OF OFFICE
65Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation
66Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
67Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
68ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm
69Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed in substucture in proportion 1:5
701st class brick nogged wall in cement including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level
71Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
72Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
73ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm
74supplying fitting and fixing cemented gnil as ventilator
75Providing undresssed wood work in roof truss raftarrs purlins tie and the like including hoisting and fixing in position with necessary spikes nalls including MS strapa, seconed class timber.
76Providing wooden in frame of doors, windows, clerestory windows and other similar works wrought framed and fixed in position in contact with CC bank massory walls including supplying fitting with ms flat hold last as per design and embeded in cement concrete block in prop 1:2:4 and with two coated of kincade oiling to the timber . 2nd class timber .
77Providing fiting and 1st class local wood battened framed and braced door shutters including oxidizied ms butt hings 6nos with necessary wood screws
78Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin et
79providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed
80Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may
81Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor.
82Miscelelaneous including sanitation and unforseen expenditure etc.
83Aquaponics culture
84Contingency including signboard
85CONSTRUCTION OF RAS CIRCULATORY MASONRY WITH PLINTH AT BIHPURIA GP
86Eartthwork in excavation for foundation trenchs of walls , retaining walls, footings of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling dresssing watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified.A) up to a depth of 2.00 m below the existing ground level. b) in hard/dense soil plinth wall
87Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:5
88Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may be necesssary . C) with river sand or slit by truck carriage including loadibng and unloading.
89Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor.
90Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on float soling circullar tank bottom.
91RCC 1:1.5:3 in super structure Providing and layong plain reinforced cement concrete works, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work by using machine mixure . A) in substructure up to plinth level Foundation , footing, columns with base tie and plinth beam pile cap base slab, retaining walls, walls of septick tank, inspaction pit and the like and other works not less than 100mm thick up to plinth level without using admixture, plasticiser m20 grade concrete or prop 1:1.5:3 RCC work at circular floor
92Brick work incent morter with 1st class brick including racking out joints and curing complete as directed. Ii) In superstucture above plinth level up to 1st floor level. In proportion 1:5 brick work in walls
93Supplying fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. Work /RB Walling including straightening , cleaning , cutting and bending to proper shaps and length as per details , supplying and binding with 20G annealed blck wire and pleacing in position with proper blocks, supports, chairs spacers etc. complete. other ISI approved TMT reinforcement bar.
94Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
95Applying epoxy coating waterproffing the tanks. Applying one coat of epoxy coating techoxy of choksey chemicals followed by two coats of polyurethane waterprof coating techcoat 61P at an interval of 12 hours each for waterproofing of external walls, roofs, terraces, chajjas etc. as specified & dierected by the Department complete. area as per above.
96INSTALLATION OF PLUMBING NETWORK
97Supplying fitting and fixing Pipe with all necessary fittings in exposed or in trenches including tranching and refilling the same etc. Complete as directed. B. uPVC pipe fittings(Using uPVC high preasure pipe) using SUPREME/PRINCE/SFMC/FUSION brand pipe
98Supplying fitting and fixing PVC pipes of 6kg/cm2 or other ISI approved including joining, fitting and fixing with clamps etc as necessary complete at all levels including below G.L as directedand specified. A. In exposed surface or in trenches. II. 110mm dia. 110mm dia pvc pipes from bottom centre of circullarpools and cornel type drain pipe carrying containment water to mechanical filter through pump/garvity flow.
99160mm dia PVC pipes connecting above 8 pipes with the drum filter
10050mm dia pvc at bottom of MBBR for areation
101Provission of valve to control the bottom central outlet of each tank 110mm dia ball valve uPVC heavy duty
102INSTALLATION OF DRUM FILTER TANK AND DRUM FILLTER
103Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2mm below the existing ground level with hard soil.
104Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) brick on flat soling
105Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
106Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
107Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
108Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
109Cost of Drum Filter SS with all accessories etc.
110INSTALLATION OF BIO FILTER (MBBR) TANK( INNER SIZE 5MX2MXDEPTH 2M)
111Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation
112Providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. A) br
113Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
114Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
115Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
116Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
117Cost of Bio Filter Media balls
118INSTALLATION OF UV TREATMENT TANK(SIZE 1.5MX2.0MXDEPTH 0.7M)
119Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation
120Providingsoling in foundation and under floor wityh stone/best quality picked jhama brics, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materils and if necessary dewatering, complete. Brick soling
121Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
122Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
123Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
124Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
125Cost of UV machine 330W
126SUMP[ FOR STORAGE OF STERILISED WATER AND INSTALLATION OF PREATURE/AXIAL PUMPS AND SUMP(SIZE 2MX5.0XDEPTH 2M)
127Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessary as directed and specified. upto a depth of 2.00m below the existing ground level.
128providing soling in foundation and under floor with stone / best quality picked jhama brick sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
129Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
130Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
131Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. 1) In Sub Structure upto plinth level including dewatering if necessary. C) in proportion 1:4
132Cement plaster skirting with cement morter in prop 1:3 finished with a floating coat of neat cement including rounding of juctions with floor. 15mm thick.
133Supply & Installation of one 3000LPM axail pumps to pump filtered water to tanks with all fittings.
134Installation of one 3HP root blower(central air blower) with all necessary piping works etc. Supply air to eight circular tanks and MBBR bottom.
135INSTALLATION OF ELECTRICAL WORKS
136Wiring for light/fan/ call bell point with 2x1.5sqmm PVC insulted single core unsheathed industrial cable FR conforming to IS-694: 1990 with flexible bright anneled electrolycticcopper conductor for voltage grade up to 110 volts with flat 19mm ISI marked casing N capping in surface system, including 6AMP flush type switch bell push GI/ MS switch boardhalf connel on wall with phanolic laminated sheet cover, celing rose etc. completed as directed and specified by the deptt.
137Wiring for drawing sub main line with PVC insulted single core unsheatheled industrial cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surfance flatt ISI marked cassing n capping system includdingh earth continiuty. with 2x 6 sqmm + earth continuty with 1x4sqmm cable in flat 25mm ISI marked casing n capping system
138Wiring for 5/6 inch 16 AMPS power plugg point with 4 sqmm PVC insulted single core unshetheled industrial cablke FR conforming to IS-694:1990 with flexible bright annealed electrolyctic copper conducvtor for voltage grade up to 1100volts with flat 19mm ISi marked cassing n capping in surfence system, including providing and fixing 5/6 pin 16 AMPS flush type shocket outlet and 16 AMPS flush type switch , GI, MS switch board with phenolic laminated sheet cover earth continuty with 2.5sqmm cable to the 3rd pin of the socket as required complete. long point up to 10.00 m length.
139Supply and installatioon & commissiong of readymade maintanence free CPRI approved chemical earthing system with 80mm dia. 2.00 m lenghth corrsion free dual pipe technology GI CHEMRODE ELECTRODE complete with RESLOW grounding minearals including excavation of earth pit in rtghe construction brick earth chember including plastering both inner & ouetr surface of brick wall as specified and directed by the department
140supplying fixing ICTP and n ling man switch ewire able fuses of 500 volte grade including drilling boards/iron framesand fixing with bolts and nuts connection as approved by the Deptt. complete as required
141supplying with fitting and fixing sheet steel, phosphatised, powder painted single door surface amounting MCB enclouse incorporated with bas-bar, neutral link earth bar and din rail etc fitted on wall with grounting nuts & bolts as reqd. Comp[lete with making necessary connection as approved specified and directed by the deptt.
142Strip[ite lumineries complete with VPIT copper ballast/ electronoic ballast and decorative end cap and 1x36/40 watt fluorescent tube model-DSG114LDBCROMGOLD/DSG11114LBDN CROM GOLD NEW / DSG1314EB CG GOLD?DSG 1414EB PLANET GOLD with super saver/ super brite lamp or equivilent PHILIPS/Wipro?BAJAJ/HEAVELS make
143CONSTRUCTION OF SHED OVER THE RAS
144Providing fitting hoisting and fixing of roof trusses including Purlins fabricated using MS Circullar hollow section conforming to relevent IS code as per approved design and drawings including providing MS cleats base plates, bolts and nuts and one coal of red oxide Zinc chormate primer and two coats of approved enamel paints complete including fittingnecessary
145PCC embedding for ms tube post for holding roof truss plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps,walls,brick works etc. As directed and specified including dewatering if necessary and curing complete in prop[ cement 3 sand 6 coarse aggregarte by volume
146Providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed
147Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin etc.
148ESTIMATE OF CONSTRUCTION OF OFFICE
149Earthwork in Excavation for foundation trenches of walls, retaining walls, footing of column, steps, septic tank etc. Including refilling the quantity as necessary after completion of work, breaking clods in return filling, dressing watterimg and raming etc. and removal of surplus earth with all lead and lifts as directed and specified in the folowing classification of soils including bailing out water where necessaryas directed and specified.up to depth of 2m below the existing ground level. use hard/dense soil. Earth work in excavation
150Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
151Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
152ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm
153Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed in substucture in proportion 1:5
1541st class brick nogged wall in cement including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level
155Providing and laying plain /reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary and cuering complete but excluding cost of form work and reinforcedmebmt for reinforce cemment works for using mixer machine in substructure up to plinth level foundation , footing , columns with base tie and plinth beam pile cap base slab retaing walls of septic rtank inspection pit and the like and other works not less than 100mm thick up to plinth level. without using admixure plaster m.20 grade concrete or proop. 1:1.5:3 footing RCC 1:1.5:3 in sub structurre floor.
156Supplyingfitting and fixing in position reinforcement bars conforming to relevent IS code for RCC work/RB Walling including straightnening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annclled black wire and placing in position with proper blockls supports chairs, spacers etc. complete
157ISI approved mild steel reinforcement dat construction of tie beam ms rod 6mm
158supplying fitting and fixing cemented gnil as ventilator
159Providing undresssed wood work in roof truss raftarrs purlins tie and the like including hoisting and fixing in position with necessary spikes nalls including MS strapa, seconed class timber.
160Providing wooden in frame of doors, windows, clerestory windows and other similar works wrought framed and fixed in position in contact with CC bank massory walls including supplying fitting with ms flat hold last as per design and embeded in cement concrete block in prop 1:2:4 and with two coated of kincade oiling to the timber . 2nd class timber .
161Providing fiting and 1st class local wood battened framed and braced door shutters including oxidizied ms butt hings 6nos with necessary wood screws
162Providing corrugated galvanised iron sheet roofing of TATA shaktee/ Shail including fitting and fixing necessary galvanised J or L hooks and nuts 8mm dia with bitumen washer 25mm diax3mm thick limpet washer comoplete excluding cost of roof truss purlin et
163providing galved iron ridging of TATA shakti/ Sail including supplying and fixing necessary galved screws washers etc. Com,plete as directed
164Earth filling in plinth in the layers not more than 150mm tyhick including necessary carriage, watering, ramming etc. Complete as directed and specifiedd including payment of land compansation, forest royality, sales tax and other duties and taxes as may
165Brick on flat floor with 1st class brick and grouted with cement morter in prop 1:4 including 15mm thick cement plastering in proportion 1:2 finishing with a floating coat of neat cement finish using cement [email protected] kg per Sqr metere of floor.
166Miscelelaneous including sanitation and unforseen expenditure etc.
167Aquaponics culture
168Contingency including signboard

AI Tender Summary

OUR REF NO 31714728
AUTHORITY Local Bodies
TENDER VALUE 1.08 Crore
LAST DATE 09-04-2022
Authority
Authority Name Zilla Parishad
Work Description Construction Of Re-Circulatory Aqua Culture System Including Aquaponics Culture At Bihpuria And Barbali Gp
Basic Detail
Tender No ZPLRURBAN004ETENDBIH2020Pt774 dtd 1/4/22
Bidding Type Tender
Location
City bihpuria
State Assam
Key Dates
Publish Date 04 Apr 2022
Submission Date 09 Apr 2022
Open Date 11 Apr 2022
Finance
Tender Value 1.08 Crore
Tender Fee 1000
EMD 2.16 Lakhs
Exemption Not Available
Document List
ca61e804-aa1c-4273-9fdc-7f74738fbc5f.html
BidDocumentRAS.pdf
BOQ_38571.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 04, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 09, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 11, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

ca61e804-aa1c-4273-9fdc-7f74738fbc5f.html

pdf

BidDocumentRAS.pdf

xls

BOQ_38571.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders