Repair Maintenance Of Desert Coolers And Single Phase Voltage Stablizers, Cooling Summer Appliances ( Ac S ) And Connected Items Of Bathinda Zone -A Under Ge ( U ) Bathinda., bathinda-Punjab

Military Engineer Services-MES has published Repair Maintenance Of Desert Coolers And Single Phase Voltage Stablizers, Cooling Summer Appliances ( Ac S ) And Connected Items Of Bathinda Zone -A Under Ge ( U ) Bathinda.. Submission Date for this Tender is 02-05-2022. Air Conditioner Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

31706573
Corrigendum : Repair Maintenance Of Desert Coolers And Single Phase Voltage Stablizers, Cooling Summer Appliances ( Ac S ) And Connected Items Of Bathinda Zone -A Under Ge ( U ) Bathinda.
Open Tender
Indian
Punjab
bathinda
02-05-2022

Tender Details

Repair Maintenance Of Desert Coolers And Single Phase Voltage Stablizers, Cooling Summer Appliances ( Ac S ) And Connected Items Of Bathinda Zone -A Under Ge ( U ) Bathinda.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Apr-2022 Corrigendum No 01 BOQ 25-04-2022
2 25-Apr-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-05-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-

BOQ Items

Name of Work: Repair maintenance of Desert Coolers and Single Phase Voltage Stablizers, Cooling Summer Appliances (AC s) and Connected itemsof BathindaZone -AUnder GE (U) Bathinda.
Sl. No. Item Description
1Taking down carefully Window Type / Split Type / Cassate Type Air Conditioner 1.50 / 2.00 Ton capacity, from its location and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with vami clean solution and other areas by soapsolution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying the blowing air, andplacing in same positionWindow Type / Split Type / Cassate Type Air Conditioner conditioner all as specified and directed by Engr-in-Charge. Note Contractor will appoint 01 Technician and 01 helper to this Ref section for day to day complaint attending and servicing and cost of the same included in this item and nothing will be paid extra on this account
2Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 1.5 Ton capacity of any make & type and Supply and Fixing NewRotary Compressorof air conditioner ofwindow Type / Split type 1.5 Ton capacity along with newfoundation rubber pads, nut and bolts including testing on full loadas directed by Engineer-in-Charegcomplete all as specified and directed by Engineer-in-Charge. Make : Hitachi / Tecumseh / GMCC.Note :- (i)The rate of newfoundation rubber pads, nut and bolts are inclusive in this item and nothing shall be paid extra on this account.(ii) Make ofRotary Compressor shall be approved by Engineer-in-Charge.(iii) The cost of charging the gas is also included in this item
3Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 2.0Ton capacity of any make & type and Supply and FixingNewRotary Compressorof air conditioner ofwindow Type / Split type 2.0 Ton capacity along with newfoundation rubber pads, nut and bolts including testing on full loadas directed by Engineer-in-Charegcomplete all as specified and directed by Engineer-in-Charge. Make : Hitachi / Tecumseh / GMCC.Note :-(i) The rate of newfoundation rubber pads, nut and bolts are inclusive in this item and nothing shall be paid extra on this account.(ii) Make ofRotary Compressor shall be approved by Engineer-in-Charge..(iii) The cost of charging the gas is also included in this item
4Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 1.5 Ton capacity of any make & type and Supply and Fixing NewReciprocatory Compressorof air conditioner ofwindow Type / Split type 1.5 Ton capacity along with newfoundation rubber pads, nut and bolts including testing on full loadas directed by Engineer-in-Charegcomplete all as specified and directed by Engineer-in-Charge. Make : Hitachi / Tecumseh / GMCC.Note :- (i)The rate of newfoundation rubber pads, nut and bolts are inclusive in this item and nothing shall be paid extra on this account.(ii) Make ofReciprocatory Compressor shall be approved by Engineer-in-Charge..(iii) The cost of charging the gas is also included in this item
5Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 2.0Ton capacity of any make & type and Supply and FixingNewReciprocatory Compressorof air conditioner ofwindow Type / Split type 2.0 Ton capacity along with newfoundation rubber pads, nut and bolts including testing on full loadas directed by Engineer-in-Charegcomplete all as specified and directed by Engineer-in-Charge. Make : Hitachi / Tecumseh / GMCC.Note :-(i) The rate of newfoundation rubber pads, nut and bolts are inclusive in this item and nothing shall be paid extra on this account.(ii) Make ofReciprocatory Compressor shall be approved by Engineer-in-Charge..(iii) The cost of charging the gas is also included in this item
6Taking downunserviceable Rotary Compressor 3 Phasefrom Cassate Type Air Conditioner 4.00 Ton capacity of any make & type and Supply and Fixing newRotary Compressor 4.00 Ton capacityof Cassate Type Air Conditioneralong with newfoundation rubber pads, nut and bolts including testing on full loadas directed by Engineer-in-Charegcomplete all as specified and directed by Engineer-in-Charge. Make :Daikin/Blue Star/ Voltas.Note :- (i)The rate of newfoundation rubber pads, nut and bolts are inclusive in this item and nothing shall be paid extra on this account.(ii) Make ofRotary Compressor shall be approved by Engineer-in-Charge..(iii) The cost of charging the gas is also included in this item
7Supply and Fixing in repair with New Fan motorof any size and any makefor cassate type Air Conditioner complete all as specified. Note:- (i) Make ofFan motorshall be approved by Engineer-in-Charge. Make and sample as approved by Engineer-in- Charge.
8Supply and Fixing in repairwith New Drain motor of any size and any makefor cassate type Air Conditioner complete all as specified.Note:- (i) Make ofdrain motorshall be approved by Engineer-in-Charge.Make and sample as approved by Engineer-in- Charge.
9Supply and Fixingin repair with NewFan motor suitable for Window Type/ Split type Air Conditionerof capacity 1.5 Ton / 2.0 Toncomplete all as specified.Note:- (i) Make ofFan motorshall be approved by Engineer-in-Charge.Make and sample as approved by Engineer-in- Charge.
10Supply and Fixing in repair with NewFan Blade Metalic (aluminium) suitable for Window Type/ SplitType Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as specified and as directed.Note:- (i) Make and sampleofFan Bladeshall be approved by Engineer-in-Charge.
11Supply and Fixing in repair with new Running Capacitor 55 mfd in Air Conditionerof any make and model complete all as specified and directed by Eng-in-Charge. Make : EPCOS / ASIAN / SIEMENS
12Supply and Fixing in repair with new Running Capacitor 45 mfd in Air Conditionerof any make and model complete all as specified and directed by Eng-in-Charge. Make : EPCOS / ASIAN / SIEMENS
13Supply and Fixing in repair withnew Running Capacitor 80-100 mfd in Air Conditionerof any make and model complete all as specified and directed by Eng-in-Charge. Make : EPCOS / ASIAN / SIEMENS
14Supply and Fixing in repair withnew Running capacitor of 6 mfdforfan motor of Air Conditioneer all as directed by Engineer-in-Charge. Make : EPCOS / ASIAN / SIEMENS
15Supply and Fixing in repairwith new Running capacitor of 2.5 mfdforfan motor of Air Conditioneer all as directed by Engineer-in-Charge. Make : EPCOS / ASIAN / SIEMENS
16Supply and Fixing in repair with new Thermostat Switch with knob suitable for Window Type Air Conditioner of any type and capacity complete all as directed by Engineer-in-charge.Note:- (i) Makeand sample ofThermostat switch with knob shall be approved by Engineer-in-Charge.
17Supply and Fixing in repair withnewPlastic Front Grill assembly complete suitable for any make window type 1.5 / 2.0 tone Air Conditioner complete all as approved and directed by Engineer-in-charge.Note:- (i) Makeand sample ofPlastic Front Grill assemblyshall be approved by Engineer-in-Charge.
18Supply and Fixing in repair with newEvaporator cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner capacity of1.5 Ton including brazing/welding etc. complete all as directed by Engineer-in-charge.Make and sample as approved by Engineer-in- Charge.
19Supply and Fixing in repair with new Evaporator cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner capacity of2.00 Ton including brazing/welding etc. complete all as directed by Engineer-in-charge.Make and sample as approved by Engineer-in- Charge.
20Supply and Fixing in repair with new Condenser coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split Type Air Conditioner 1.5 ton including brazing/ welding etc. complete all as directed by Engineer-in-charge.Make and sample as approved by Engineer-in- Charge.
21Supply and Fixing in repair withnew Condenser coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split Type Air Conditioner 2.0 ton including brazing/ welding etc. complete all as directed by Engineer-in-charge.Make and sample as approved by Engineer-in- Charge.
22Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split TypeAir Conditioner complete all as approved and directed by Engineer-in-charge.Note :- The rate ofMaterial and Labour for chargingof gas R-22 is included in this item and nothing shall be paid extra on this account.
23Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-410 upto the required pressure for 2.00 Ton /1.5 Ton Split Type/ Cassate Type Air Conditioner complete all as approved and directed by Engineer-in-charge.Note :- The rate ofMaterial and Labour for chargingof gas R-410is included in this item and nothing shall be paid extra on this account.
24Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-32 upto the required pressure for 1.5 Ton/ 2 .00 Ton Window / Split Type Air Conditioner complete all as specified and directed by Engineer-in-charge.Note :- The rate ofMaterial and Labour for chargingR-32 is included in this item and nothing shall be paid extra on this account.
25Supply and Fixing in repair withnewReverse valve (gun metal) for Window Type / Split TypeAir Conditioner of 1.5 Ton / 2.0 Ton including copper pipe and includinggas charging as required. All as specified and directed by Engneer-in-Charge.Make and sample as approved by Engineer-in- Charge.Note :- The rate of material and labour for charging gas in Reverse valve is included in this item and nothing shall be paid extra on this account.
26Supply and Fixing in repair with new PCB including Remote Control for remote sensing and operation suitable for Window Type/ Split Type Air Conditioner 1.5 Ton/ 2.0 Ton make as approved by Engineer-in-charge.Make :LG / Voltas / Blue Star / Hitachi
27Supply and Fixing in repair with new PCB including remote control for remote sensing and operation suitable for Cassate TypeAir Conditioner 2.00 Ton / 4.00 Ton make as approved by Engineer-in-charge.Make :Voltas / Daikin / Blue Star
28Supply and fixing in repair with new invertor PCB including remote control for remote sensing and operation suitable for window / split type (indoor and outdoor complete)air conditioner1.5/2.0 ton make as approved by Engineer-in-charge. Make : Daikin/Blue Star/Hitachi/voltas/diakin
29Supply and Fixing in repair with new indoor unit complete suitable for 1.5 Ton Split Type Air conditioner complete all as per manufacturer"s instructions and as directed by Engineer-in-ChargeMake :Hitachi(ryoku)/whirlpool/ carrier (Total line)
30Supply and Fixing in repair with new out doorunit complete suitable for 1.5 Ton split Type Air Conditionercomplete all as per manufacturer"s instructions and as directed by Engineer-in-Charge: Make :Hitachi (ryoku)/whirlpool/carrier(total line)
31Supply and Fixing Metal clad Earth plug 32 A 3 Pole, 230V Ac all as specified and directed.Make : As approved by Engineer-in-Charge. Make :- LEGRAND/SCHNIDER / ABBSIEMENS / HAVELLS
32Supply and FixingMetal clad Earth Socket 32 A 3P, 230V Ac all as specified and directed. Make :-LEGRAND / SCHNIDER/.ABB /SIEMENS /HAVELLS
33Providing labour only for attending complaints and removing of split type AC locating at ground floor / first floor /second floor/ third floor installed in Messes,offices/ Labs / MH at any locationof Bathinda cantt and placing at its original position after removingthecomplaintsall as specified and as directed by Engr-in-Charge.
34Taking out unserviceable Blower motor from the indoor unit split TypeAir Conditionerof any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required. All as specified and as directed by Engr-in-Charge.Make and sample as approved by Engineer-in- Charge.
35Supply& FixingPVCinsulated three core multi stranded copper conductor, 2.5 sq.mm, as in wiring including connecting up and testing including Taking down existing unserviceable wiring of any description and size all as specified and as directed by Engineer-in- charge .Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDUSTRIES LTD / PLAZA / PARAGON / HPL / RR KABEL LTD
36Shifting & Fixing only Air Conditioner, Window Type/ Split Type up to 2 TR from existing location to other location and installing, connecting up, commissioning and testing complete all as specified and as directed.
37M & L for Copper tube, 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, copper tube9mm diadischarge line drawn trough pipes / fixed to walls / laid on floor or roof all as specified and as directed. by Engineer-in- Charge .Make and sample as approved by Engineer-in- Charge. Note : Copper tube, 15 mm / 18 mm dia and copper tube 9mm diadischarge line -1.00 Running Metre bothcopper tubes shall be measured and paid in single lengthPer Running Metre.
38Supply and FixingMCB SP 32 A "C" curvecomplete all as specified .Make : Make : LARSEN & TUBRO/ SIEMENS/LEGRAND/SCHNEIDER/HAVELLS INDIA LTD/C & S ELECTRIC LIMITED (C & S)/ABB
39Supply and Fixing in replacementold unservicable chassis unit made out of MS sheet suitable for 1.5 Ton Window Type Air Conditinor with remote sensing system complete , duly spray paintedwith two coats of synthietic enamel paintcolour (shade of colour as approved by Engineer-in- Charge) , including heavy duty copper tubing and copper fins evaporator coil, condenser coil ,copper wounded fan motor and suitable front grill etc. complete all as directed by Engineer-in-charge. Make and sample as approved by Engineer-in- Charge.
40Disconnecting the electrical and water connections of desert cooler and taking down from its position installed at any floor of the building, opening the side pannels and remove the unserviceable/dirty wood wool pad/ khas khas pad, dismantled the front grill including piano type swiches, regulators, rotary switches, etc. Scratching out the old paint from inner and outer surfaces of cooler with sand emery paper complete and cleaning to make smooth surface for painting, painting the inner side of the body with two coats of anticorrosive black paint and outer surface with two coats of silver ash hammerton paint with spray gun machine including painting the air direction change grill and fixing the desert cooler and its parts complete as original and at original place including making water and electrical connection and testing etc complete all as specified and as directed by Engineer-in-Charge. Note :- (i)Wood wool pad / khas khas pad,PVC connection 45cm long and 15mm dia with PTMT nuts including PVC washer,PVC distributor three way , PVC Eblow , PVC flexible pipeshall be measured and paid under appropriate item of Schedule of BoQ as supply and fixing.(i) The rate ofnut, bolts, screws etcif required shall be measured and paidunder this item and nothing shall be paid extra on this account.
41Taking out the unserviceable fan motor from desert cooler of any make and type from AGE E/M (Refg) store yard and carry to local market, dismanting the fan motor complete, removing the copper/aluminium burnt winding, cleaning the stator and then rewinding the stator with super enamlled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class "B" varnish for insulation including painting thebody of fan Motor with two coats of synthetic enamel paint, reassembling the complete fan motor and re-fixing in the desert cooler at AGE E/M (Refg) store yard as per direction of AGE E/M (Refg) and testing complete all as directed by Engineer-in-Charge.Note :- (i) The rate ofMaterial and Labourof super enamlled copper winding wire , High grade material class "B" varnish is included in this item and nothing shall be paid extra on this account (ii) Ball bearing , shaft , gun metal bushif replaced shall be measured and paid separately under apprpriate items ofSchedule"A" BOQ as a supply onlyandthe rate of labour elementof fixing of these itemsis included in this item and nothing shall be paid extra on this account. (iii) The T & P/Vehicle will be arranged by the contractorat his own cost to carry fan motor for repairto local market and back and the costis included in this item and nothing shall be paid extra on this account. (iv)Sample and Make of super enamlled copper winding wireandvarnish high grade material and class "B" shall be approved by Engineer-in-Charge.
42Supply and fixingNew front grill complete heavy duty having minimum weight 3 Kgs made out of GI sheet including fixing plate complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineer-in-Charge.
43Supply and fixing repair new PVC connection 45cm long and 15mm dia with PTMT nuts including PVC washer complete all as specified and as directed by Engineer-in-Charge. Make and sample as approved by Engineer-in-Charge.
44Supply and fixingin repair newcapacitor 4 mfd complete all as specified and as directed by Engineer-in-Charge. Make Asian/Keil/Jyoti.
45Supply and fixingrepairPVC distributor three way superior quality complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineeer-in-Charge.
46Supply and fixing repair PVC Eblow superior quality suitable for desert cooler of any capacity complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineer-in-Charge.
47Supply and fixingrepair PVC flexible pipe superior quality heavy duty suitable for desert cooler of any capacity complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineer-in-Charge.
48Supply and fixing in repair withnewwater pump for desert coolers 230 Volts, 50 Hz speed not less then 1300 RPM including repair newof nut and bolts complete all as specified and as directed by Engineer-in-Charge. Make : Crompton greaves/GEC/Nelco/Khaitan
49Taking down usserviceable fan motor includingfan blade ,MS legs and rubber pads from the desert cooler including supply and fixing withNew fan motor of copper winding 1/6 HP single phase 230 V three speed including fan blade , MS legs (set of four) and rubber pads complete all as specified and as directed by Engineer-in-Charge.Make : Crompton greaves/GEC/Nelco/American universal/Khaitan/cool home
50Supply and fixing wood wool pads (Set of three) weight not less than 500gms superior quality complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineer-in-Charge.
51Supply and fixing in repair with new desert cooler body ofsize 27.5 inch x 27.5 inch x 33 inch made out of GI plain sheet of 20 SWG and side panels of 22 SWG without front grill but with and including nuts, bolts, and washer including painting the inner side of the body with two coats of anticorrosive black paint and outer surface with two coats of silver ash hammerton paint with spray gun machine complete all as specified and as directed by Engineer-in-Charge.
52Supply and fixing in repair newaluminium fan blade 21" dia suitable for desert cooler any make and any type all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineer-in-Charge.
53Supply and fixing in repair new ply wood board of size 8" x 4"12mm thich in cut sizes as required at site for desert cooler with and including support for fixing of ply wood including painting with one coat of pink primer and two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
54Supply and fixing in repairwith new piano switch, flush type 5 Amp, 240 Volts, single pole, one way complete all as specified and as directed by Engineer-in-Charge.Make : ANCHOR/ HAVELLS / SSK / LEGRAND / LEADER / MDS
55Supply and fixing in repair with new rotary switch with PVC knob single pole to operate cooler 5 Amp, 240 Volts, single phase including testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Make : ANCHOR/ HAVELLS / SSK / LEGRAND / LEADER / MDS
56Supply and fixing in repairwith new PVC float valves, high pressure, with polythene float and fly-nut (PTMT) complete,screwed for iron pipe of brass ferrule, suitable for 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge.Make - PRAYAG/ PARRYWARE / COMMANDER / LEADER / CERA
57Supply and fixing in repair new 3 pin, 5 Amp top plug, 240 Volts, single phase complete all as specified and as directed by Engineer-in-Charge.Make : ANCHOR/ HAVELLS / SSK / LEGRAND / LEADER / MDS
58Supply and fixing in repairwith new copper cable 3 core round of size 23/0.0076 ,3.00 Mtr long including making connection all as specified and as directed by Engineer-in-Charge.Make : Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDUSTRIES LTD / PLAZA / PARAGON / HPL / RR KABEL LTD
59Material and labour for cutting of burnt transformer of Voltage stablizer 4 KVA to 5 KVA capacity and rewinding the same with supper enamelled copper winding wire of the existing guage, including varnishing, providing all high grade material and class "B"varnish for insulationmaterial includingSuitable PCB , replacement of relay unit , volt metre,assembling and all incoming and out going connection of stablizer and testing upto entire satisfaction of Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Note:(i) The rate ofMaterial and Labourof super enamlled copper winding wire , High grade material class "B" varnish Suitable PCB , relay unit , volt metre is included in this item and nothing shall be paid extra on this account (ii) The T & P/Vehicle will be arranged by the contractorat his own cost to carryfor repairto local market and back and the costis included in this item and nothing shall be paid extra on this account.(iii) Sample and Make of super enamlled copper winding wireandvarnish high grade material and class "B" shall be approved by Engineer-in-Charge.
60Material and labour for cutting of burnt transformer of Voltage stablizer 2 KVA to 3 KVA capacity and rewinding the same with supper enamelled copper winding wire of the existing guage, including varnishing, providing all high grade material and class "B"varnish for insulationmaterial includingSuitable PCB , replacement of relay unit , volt metre,assembling and all incoming and out going connection of stablizer and testing upto entire satisfaction of Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Note:(i) The rate ofMaterial and Labourof super enamlled copper winding wire , High grade material class "B" varnish Suitable PCB , relay unit , volt metre is included in this item and nothing shall be paid extra on this account (ii) The T & P/Vehicle will be arranged by the contractorat his own cost to carryfor repairto local market and back and the costis included in this item and nothing shall be paid extra on this account.(iii) Sample and Make of super enamlled copper winding wireandvarnish high grade material and class "B" shall be approved by Engineer-in-Charge.
61Material and labour for cutting of burnt transformer of Voltage stablizer 0.5 KVA to 1.5 KVA capacity and rewinding the same with supper enamelled copper winding wire of the existing guage, including varnishing, providing all high grade material and class "B"varnish for insulationmaterial includingSuitable PCB , replacement of relay unit , volt metre,assembling and all incoming and out going connection of stablizer and testing upto entire satisfaction of Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Note:(i) The rate ofMaterial and Labourof super enamlled copper winding wire , High grade material class "B" varnish Suitable PCB , relay unit , volt metre is included in this item and nothing shall be paid extra on this account (ii) The T & P/Vehicle will be arranged by the contractorat his own cost to carryfor repairto local market and back and the costis included in this item and nothing shall be paid extra on this account.(iii) Sample and Make of super enamlled copper winding wireandvarnish high grade material and class "B" shall be approved by Engineer-in-Charge.
62Supply & fix in repair Sheet metal enclosure having provision for a two pin and earth plug and socket complete with one single pole MCB up to 32 Amps, 240 volt capacity and tested on completion complete all as specified by Engr-in-charge. Note: Cost of MCB and Two pin earth plug and socket will be paid under appropriate item of schedule Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDU
63Supply and fix in repairTK foam heat insulation tube of size 1/2inch x3/8 inch (inner dia x thickness)for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant type complete all as specified and directed by Engr-in-charge
64Supply and fix in repairTK foam heat insulation tube of size 1/2inch x3/8 inch (inner dia x thickness)for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant type complete all as specified and directed by Engr-in-charge
65Supply and fix in repair swing motor for indoor split AC/window AC of any make and capacity all as specified and directed by Engg-in-Charge.
66Supply and fix in repair blower for indoor split AC of any make and any capacity all as specified and directed by Engg-in-Charge.
67Supply and fix in repair indoor Split AC flexible drain pipe made of PVC of length not less than 5 meter and dia not less than 15mm all as specified and directed by Engg-in-Charge
68Supply and fix in repair outdoor unit AC stand including with nuts,bolts,rubber pads etc complete for mounting outdoor unit of split AC of any make and any capacity all as specified and directed by Engg-in-Charge
69M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian no metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing including taking down existing onecomplete all as specified and directed. (Note : 2 runs of 4 sqmm cable, 1 run of 2.5 sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run). Make : Polycab/Havells/HPL/Finolex/Anchor
70Supply, fixing in repairof 5.0 KVA capacity Voltage stabilizerfor automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 150V - 250V with output voltage stabilized at 230V with accuracy of (+) or (-) 2.5% complete.
71Supply and fix in repair dust proof/water proof protection cover of polyster materialfor indoor and outdoor unit complete set