Military Engineer Services-MES has published 8601 / Bkt / E8 Repair / Maintenance Of Summer Cooling Appliances With Allied Works At Af Stn Bkt. Submission Date for this Tender is 28-04-2022. Air Conditioner Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Apr-2022 | CORRIGENDUM | Other | 21-04-2022 |
2 | 21-Apr-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-04-2022 |
Sl. No. | Item Description |
1 | Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for window type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge |
2 | All as per Item No 1 here in before but for split AC 1.5 Ton Capacity |
3 | All as per Item No 1 here in before but for split AC 2.0 Ton Capacity |
4 | All as per Item No 1 here in before but for Water cooler |
5 | All as per Item No 1 here in before but for Refrigerator Note for Item No 1 to 5 :-(i)Unit rate include transportation to site of work & back as applicable(ii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor |
6 | S&F Indoor blower motor of Split type AC 1.5 Ton capacity existing make with supper enameled copper winding fixing and testing on load including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge |
7 | All as per Item No 8 here in before but for split AC 2.0 Ton Capacity |
8 | All as per Item No 8 here in before but for Water cooler any capacity |
9 | S&F Blower motor of window type room air conditioner 1.5 Ton capacity existing make with supper enameled copper winding fixing and testing on load including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge |
10 | All as per Item No 9 above here-in-before but out door unit split type AC capacity 1.5 TR |
11 | All as per Item No 9 above here-in-before but out door unit split type ACcapacity 2.0 TR |
12 | All as per Item No 9 above here-in-before but Water cooler |
13 | All as per Item No 9 above here-in-before but Desert coolerMake :AUE/Universal/Khatain/Bajaj |
14 | Re-winding of blower motor of desert cooler any capacity any make with supper enameled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, fixing and testing on load complete all as specified and directed by Engineer-in-Charge |
15 | S&F Starting capacitor 80-100 mfd for window/Split type room air conditioner 1.5/2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge Make :Epcos/Havells /Usha/ Tipcon |
16 | All as per Item No 15 here-in-before but 4 mfd |
17 | All as per Item No 15 here-in-before but 6 mfd |
18 | S&F Running capacitor 10 mfd for water cooler including taking out the old unserviceable capacitor complete all as specified and didfrected by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon |
19 | All as per Item No 18 here-in-before but 20 mfd |
20 | All as per Item No 18 here-in-before but 36 mfd |
21 | All as per Item No 18 here-in-before but 45 mfd |
22 | All as per Item No 18 here-in-before but 50+6 mfd |
23 | All as per Item No 18 here-in-before but 55+6 mfd |
24 | S&FStarting relay for 1.5 Ton window type AC including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge Make :Renutrol/indfoss |
25 | All as per Item No 24 here-in-before but for split type AC |
26 | All as per Item No 24 here-in-before but for water cooler |
27 | All as per Item No 24 here-in-before but for Refrigerator |
28 | Thermostatic switches for any capacity for window/split type AC including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-ChargeMake:Renutrol/Indfoss |
29 | All as per Item No 28 here-in-before but for water cooler |
30 | All as per Item No 28 here-in-before but for Refrigerator |
31 | S&F MS front bottom panel of water cooler duly spray painted to match with the existing water cooler including dismantling/taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge |
32 | S&F Chromium plated drip tray assembly of water cooler complete with elbow including dismantling/taking out the old unserviceable drip tray complete all as specified and directed by Engineer-in-Charge |
33 | S&F Hose pipe 20 mm dia synthetic PVC rubber corrugated of standard length for wadter cooler complete with two clamps (worm gear type) one on each side including dismantling the old unserviceable hose pipe complete all as specified and directed by Engineer-in-Charge |
34 | S&F 20 mm dia PVC pipe cotton bralded for water cooler connection complete all as specified and directed by Engineer-in-Charge |
35 | S&F15 mm dia PVC (heavy duty) pipe for desert cooler complete all as specified and directed by Engineer-in-Charge |
36 | S&F20 mm dia MS clamp (worm gear type) for PVC pipe including dismantling the old unserviceable clamp complete all as specified and directed by Engineer-in-Charge |
37 | Replace/in repair Circuit board PCB of Split Type AC complete for 1.5/2.0 TR Split type A/C and complete testing as per directed |
38 | Repair and maintenance of Circuit board PCB complete for 1.5/2.0 TR Split type A/C and complete testing as per directed |
39 | S&F Indoor unit of split type AC capacity 1.5 TR including evaporator coil ,blower ,blower motor,controling circuit of AC complete all as specified and directed by Engr-in Charge. Make- LG,Carrier ,Daikin ,Samsung |
40 | All as per Item No 39 here-in-before but for Capacity 2.0 TR |
41 | S&F Blower fan blade complete for desert cooler all as specified and directed by Engineer-in-Charge Make : AUE/Universal/Khaitan/Bajaj |
42 | S&FCable PVC insulated sheathed 3 core copper conductor size 40/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge |
43 | S&F Push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler including dismantling the old unserviceable push cock complete all as specified and directed by Engineer-in-Charge |
44 | Maintenance, servicing cleaning of window type room air conditioner 1.5 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load.Replacement of spare or gas shall be measured and paid separely under respective item |
45 | Maintenance, servicing cleaning of split type air conditioner 1.5/2 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load.Replacement of spare or gas shall be measured and paid separely under respective item |
46 | Maintenance, servicing & repair of refrigerator any capacity any make model cleaning the various components i. e Chill tray, Shelves, Freezer door, Door Gasket,Door Lock,Blub Holder & bulb and Food tray and replacemnt of minor spare parts complete all as specified and directed by Engineer-in-Charge |
47 | Maintenance, servicing & repair of Deep freezer any capacity any make model cleaningcomplete all as specified and directed by Engineer-in-Charge |
48 | S&F Defrost timer for domestic refrigerator including dismantling the old unserviceable timer all as sample and directed by Engineer-in-Charge Make : Samsung/Godrej/Whirpool |
49 | Allas per Item No 48 here-in-before but Bimetal relay |
50 | Allas per Item No 48 here-in-before but Defrost heater |
51 | Allas per Item No 48 here-in-before but Fan motor assy alongwith fan blade |
52 | Allas per Item No 48 here-in-before but over load proection for refrigerator |
53 | Allas per Item No 48 here-in-before but PTC relay |
54 | S&FCondenser line filter for window/split AC complete all as specified and directed by Engineer-in-Charge |
55 | S&FCondenser line filter for Refrigeratorcomplete all as specified and directed by Engineer-in-Charge |
56 | S&FCondenser line filter for Water coolercomplete all as specified and directed by Engineer-in-Charge |
57 | Maintenance & servicing of water cooler any capacity and any make at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condensor motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis, connecting & testing on load for performance all as directed by Engineer-In-Charge Note:Spareshall be measured and paid separately |
58 | Spray painting to water cooler 40/80 Ltrs & 120/150 Ltrs with one coat of synthetic enamel paint (colour as per original shade) including writing of SM No over the body with white/black paint all as per specified and directed by Engineer-in-Charge |
59 | Taking out the existing rusted/worn out base plate of water cooler 40/80 ltrs & 120/150 Ltrs capacity by disconnecting the compressor, condenser motor, providing new MS base plate including welding work and straightening of base plate & re-fixing the compressor, condensor & condenser motor making all connection, charging gas and testing on load all as specified and directed by Engineer-in-Charge |
60 | S&FGrill of window type room air conditioner 1.5 ton capacity suitable for any make & model as existing at site including dismantling old grill complete all as specified and directed by Engineer-in-Charge |
61 | Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparations surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and oiling the pump & motor complete all as specified and directed by Engineer-in-Charge |
62 | Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5 Ton capacity and providing the new condensing unit of exsting size model in place including welding, brazing etc and tdesting on load all as specified and directed by Engineer-in-Charge |
63 | All as per item No 65 here-in-before but evaporator coil |
64 | All as per item No 65 here-in-before but water cooler |
65 | Replace air filter suitable for window type AC 1.5 Ton capacity all as per sample and directed by Engineer-in-Charge |
66 | All as per Item No 65 here-in-before but for split type AC |
67 | Supply &fix Submersible pump for desert cooler (in replacement) for lifting water upto 1.2 meter head. Make : Champian/Crompton Graves/Meghdoot/Usha. |
68 | S&FWood wool pad set suitable for desert cooler heavyy duty including dismantling the old unserviceable wood wool pad set all as directed by Engineer-in-Charge |
69 | Re-winding of main transformer of voltage stabilizer capacity 5 KVA with super enameled copper winding wire of suitable gauge including making connection by soldering and testing complefte all as directed by Engineer-in-Charge |
70 | All as per Item No 69 here-in-before but 4 KVA |
71 | Relay for voltage stabilizer 240 volts all as per sample and required at site including dismantling the old unserviceable relay |
72 | Volt meter 0-300 volts fixed as in repair |
73 | Amps meter 0-30 Amp fixed as in repair |
74 | S& F Timer circuit for voltage stabilizer including dismantling the old unserviceable timer circuit all as per sample and required at site complete all as specified and directed by Engineer-in-Charge |
75 | S&F Connector porcelain type for voltage stabilizer including dismantling the old unserviceable porcelain complete all as specified and directed by Engineer-in-Charge |
76 | S&F Float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge |
77 | S&F15 mm dia PVC connection to water coolers 450 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge |
78 | S&FSheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make Havells/MDS/Legrand |
79 | Taking down unserviceable split AC and re-fixed to its original position after repairing including welding and brazing of copper pipe including charging of gascomplete testing all as specified and directed by Engineer-in-Charge |
80 | Supply and fixing of Copper Pipe size 5/8"( with sleeves)including welding brazing of copper pipe |
81 | Supply and fixing of Copper Pipe size 1/4"( with sleeves)including welding brazing of copper pipe |
82 | Supply and fixing of Copper Pipe size 1/2"( with sleeves)including welding brazing of copper pipe |
83 | Supply and fixing of Copper Pipe size 3/8"( with sleeves)including welding brazing of copper pipe |
84 | S&F insulation for cooper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split AC complete all as specified and directed by Engr-In-Charge. |
85 | Supply and fixing of selector switch combination of 4 switches(for low,med,high & pump on/off) for desert Cooler as per sample complete with connection all as specified and directed |
86 | Supply and fixing of Blower assembly for split type AC any capacity |
87 | Supply and fixing of condenser fan suitable for Window type AC any capacity |
88 | Supply and fixing of condenser Fan Suitable for Split Type AC any capacity |
89 | Supply and fixing of Top Plug3 pin 220 Volt 5 Amp Make :- Anchor/Plaza/Havells |
90 | Supply and fixing of Top Plug3 pin 220 Volt 15 Amp Make :- Anchor/Plaza/Havells |
91 | S&F Industrial protected socket with cap and chain 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells |
92 | S&F Industrial protected plug top 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells |
93 | Supply and fix blower for split AC 1.5 Ton capacity for indoor unit |
94 | Supply and fix blower for split AC 2 Ton capacity for indoor unit |
95 | M&L for repair to remote circuit complete with remote device for 1.5/2 TR window/split type AC and complete testing as per directed |
96 | S&F in repair MCB protected socket combination including MCB of capacity 25 amps withsteel sheet/plastic enclosure with plug topAC 230 V complete all as specified and directed |
97 | S&F in repairMCBsingle pole, 20 to 32Amps, 240 Volts 50 HZ,"C" series 10 KA breaking capacity complete all as directed. |
98 | S&F Cable PVC insulated sheathed 3 core copper conductor size 70/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge |
99 | S&F Cable PVC insulated sheathed 3 core copper conductor size 110/0.0076mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge |
100 | S& F contactor single phase single pole 25 A ,220 Volt,50 Htz suitable for split AC out door unit complete testing all as specified and directed by Engineer-in-Charge |
101 | M&L for charging of refrigerant gas (R-22 /32/ 134 (a) / 410 c ) in split/window type AC after detecting leakage test with CO2 gaswith provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge. |
102 | All as per item no. 101 here in before but for water cooler |
103 | All as per item no. 101 here in before but for refrigerator |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy