Supply Installation Testing And Commissioning Of Transformer Substation Supply Installation Testing And Commissioning Of Transformer Substation 250 Kva And Dg Set 125 Kva At Gharsana, Raisingnagar And Head Office Rswc Jaipur. , Transformersubstations -2, gharsana-Rajasthan

Rajasthan State Warehousing Corporation-RSWC has published Supply Installation Testing And Commissioning Of Transformer Substation Supply Installation Testing And Commissioning Of Transformer Substation 250 Kva And Dg Set 125 Kva At Gharsana, Raisingnagar And Head Office Rswc Jaipur. , Transformersubstations -2. Submission Date for this Tender is 20-04-2022. Footwears Tenders in gharsana Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

31681104
Corrigendum : Supply Installation Testing And Commissioning Of Transformer Substation Supply Installation Testing And Commissioning Of Transformer Substation 250 Kva And Dg Set 125 Kva At Gharsana, Raisingnagar And Head Office Rswc Jaipur. , Transformersubstations -2
Open Tender
Indian
Rajasthan
gharsana
20-04-2022

Tender Details

Supply Installation Testing And Commissioning Of Transformer Substation Supply Installation Testing And Commissioning Of Transformer Substation 250 Kva And Dg Set 125 Kva At Gharsana, Raisingnagar And Head Office Rswc Jaipur. , Transformersubstations -250 Kva , S I T C Of Star Aluminium Wound Distribution Of Following Rating 11 / 0.433Kv Delta-Star Connected, Vector Group Dyn 11, Onan Cooled & As Per Bee Star Level- 2 & Bis Approved As Per Is 2026- 1977 & Lossesas Defined As Per Is 1180 Part I 2014. Including Standardaccessories Like Conservator, Silica Gel Breather, Radiator, Fins, Ht Cable Box & Lt Cable Boxes, Temperature Rise In Winding / Oil 35-40 Degree C Upto 200 Kva & 40-45 Degree C For Above 200 Kva, Isi Marked Drain Valve, Dial Type Temperature Gauge, First Filling Of Transformer Oil As Per Is :335-1953, Epoxy Based Paint, Including Carrying Of Pre-Commission Testing & Charging Of Transformer Complete In All Respect .Nabl Accredeated / Cpri / Erda Lab Testing Reports With Oem Certificate Must Submitted To Engineer In Charge .Transformer Must Be Tested From Ctl Test Lab Of Discom ( If Reqd. ) Before Charging Of Transformer & Complete Installaion Must Be Certified From Electrical Inspectorate Office As Per Indian Electricity Rule, Ctl Testing Charges & Inspection Charges Shall Be Reimbursed By The Department To The Contractor As Per Actual Expenditure. All Asperpreapprovedbyengineerincharge. Foradditionaltechnical Parameters Of Products / Work , Referannexure A Attached. 250 Kva With Off -Ltc ( +5% To - 10% @ 2.5% ) , Supply , Installation, Testing And Comissioning Of 11Kv, 630 A, 25 Ka / 1 Sec, Sf6 / Vcb Indoor Type Panel Ht Board, Free Standing Motor Operated & Withdrawaltypefabricatedfrom2mmthickcrcasheetsteel, With Ammeter, Voltmeter, Pf Meter, Kwh Meter, Mdi Meter, Selector Switches As Required, Crt-Ct Of Required Ratio ( 15Va ; Cl-1.0 / 0.5 ) Pt ( 11 Kv / 110V / V3 ) , Fuses , Ip42 Protection, 4 / 8 / 10 / 12-Window Annunciation Panel , Ac / Dc Control Voltage 24 / 48 / 110 / 230V , Led Indication Lamps , S / C, O / C & E / F Protection ( Idmt ) Relays Alarm & Trip Contacts For Transformer Protection ( Highoiltemperature, Buchholzprotection, Highwindingtemperature ) , Power Pack 2 X 12 V, Etc Complete In All Respect Ready To Use ( Rtu ) , Oem Must Have Bis Certificate And&Shall Have Submitnabl / Cpri / Erda Lab Type Test Reportsbefore Execution Complete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work. , Supply , Installation, Testing And Comissioning Of Factory Made11 Kv, 630 A, 20Ka / 3 Sec, Out Door Extensible Type Ip54 For Panel & Ip67 For Main Circuits Ring Main Unit ( Rmu ) Iec 62271-200In Suitable Rcc Foundation With 2 No. Load Break Switch & 1 No. Vcb / Sf6 Circuitbreaker With Over Load, Earth Fault, Short Circuit Relay, Copper Bus Bar, Bus Support And Insulation Marerial Epoxy Resin, Ring Core Protection & Metering Ct, Auxiliary Relay For Wti, Oti , Bucholz Alarm & Trip Along With Annuciator Panel, Master Trip Relay, Mechanical On / Off / Earth Indication, Voltage Presence Indicator, Shunt Trip Coil, 24 V Dc Power Pack, Digital Multi Function Meter, With Bus Pt Panel With 3 Nos Single Phase Voltage Transformers Of The Ratio 11Kv / V3 / 110 V / V3, 25 Va, Class 1.0 With Ht Fuses In The Primary And Mcb On The Secondary Side, Voltmeter With Selector Switch, R Y B Phase Indication, Anti Reflex Operating Handle, Right Angle Boots Etc. Oem Must Have Bis Certificate And&Shall Have Submitnabl / Cpri / Erdalab Tpye Test Reportsbefore Execution As Requiredcompleteinallrespect.Allasperpreapprovedbyengineerin Charge. Foradditionaltechnicalparametersofproducts / Work , Refer Annexure A Attached . , Supply, Installation, Testing Andcomissioning Of1 No.Vcb / Sf6 Circuit Breaker Coupled With Existing Extensible Type Rmuwith Over Load, Earth Fault, Short Circuit Relay, Copper Bus Bar, Ring Core Protection Ct 2.5 Va, 10P10 As Per Transformer Rating, Mechanical On / Off / Earth Indication, Voltage Presence Indicator, Anti Reflex Operating Handle, Right Angle Boots Etc. As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. Foradditionaltechnicalparametersofproducts / Work , Refer Annexure A Attached. , Supplyandfixingofiso / Biscertifiedmadeaccessoriesof Transformer Above 500 Kva Rating I.E. Winding Temperature Indicator ( Wti ) , Oil Temperature Indicator ( Oti ) , Magnetic Oil Level Gauge ( Mog ) , Bucholz Relay With Alarm & Trip Contacts & Marshalling Box Including Making Connection & Testing Etc As Required Complete In All Respect. Appropriate Oem Test Reports Of All Items Shall Be Submitted.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Referannexure A Attached. , Supply&Installationofd.P.Structurewithairbreakswitchhaving Following Specifications:- All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Dp : Double Pole Structure On 2 No Ismb 150 X 100 Mm, 10 Mtr High Using 7 No Ms Channel Each Of Size 100 Mm X 50 Mm X 2500 Mm Complete In All Respect With Nuts, Springs Washers, Clamps As Required. Go:Off Load Type Gang Operated 3-Pole Vertical Flute Type Switch Suitable For 11Kv ; 400A , 3-Ø, Central Post Rotating Double Break Isolator Complete With Ms Hardware , Copper Moving & Fixed Contact , Assembly Of 9 Nos Pin Insulator, Gi Pipe Of Suitable Length For Operation. Do: 3Nos Vertical / Horizontal Mounted 11Kv Horn Gap Fuse Set / Drop Out 11Kv Barrel Fuses Mounted On 6No Pin Insulators.La:3Piecenonlinearresistortype.Lightingarrestorofapprovedmake Suitable For 3 Wire, 11Kv Overheadline With Rated Voltage Of 9Kvrms & Nominal Discharge Current Rating Of 5 Ka & Complete With Galvanized Clamping Arrangement Gi Bolts, Nuts, Washer Etc As Required. Jumpers: 3 No 11Kv Acsr Conductors Mounted On Pin Type Insularors As Required.6.General:Thegoshallbeoperatedbyhandoperatedliver Properly Earthed With Provision For Locking Mounted At 3’ , Dg Set ( 160 Kva ) , Supply , Installation, Testing And Comissioning Of Silent Dg Set ( As Per Latest Cpcb Emission Norms ) Having Specifications As Per A, B, C, D, E, F, G, H , A.1500 Rpm Diesel Engine Conform To Bs:649 / 5514 Of Suitable Bhp Engine Shall Have Residential Silencer ( Isolated From Main Dg Chamber ) , Up To 3 M Exhaust Piping ( With Insulation & Cladding ) As Required . , B.Ac Brush Less Spdp Alternator Conform To Bs 5000 ( Part 99 ) Or Is 4722.-2001 . Alternator Shall Be Self Regulated With Standard Alternator Protection ( Over Voltage , Over Speed & Under Voltage, Under Speed Warning & Shutdown ) .Engine&Alternatormountedonacommonbaseframe& Coupled Through A Flexible Coupling Or Close Coupled , C. Standard Canopy With Weatherproof, Powder Coated Accoustic Enclosure For Dg Set For Sound Attenuation Fabricated From 1.6 Mm Crca Sheet Steel ( Structure ) With Side Wall Fabricated From 1.6 Mm Crca Sheet & Filled With Glass Wool ( 96Kg / M3 ) / Foam. As Per Is 8183 The Doors Of 28 / 40 / 50 / 85 Mm Thick As Per Rating And Fabricated From 1.6Mm Crca Sheet Packed With Accoustic Material, All Doors / Opening Are Sealed With Neoprene / Epdn Gaskets. The Enclosure Has Built In Fuel Tank, With Protection And Tripping Of Dg Set Against Temperature Of More Than 50 Degree Centigrade , D. Electronic / Mechanical Governor, Manual & Electric Start , Batteries With Battry Charger, Engine Instruments Panel, Avm Pads All Controls For Operation Of Dg Set Are From Outside The Enclosure With Dg Control Panel Having Microprocessor Based Genset Monitoring & Control System, Mccb / Acb Of Suitable Rating, Ammeter, Voltmeter, Pf Meter, Frequency Meter, Kwh Meter, Digital Fuel Display Meter, Ind.Lamps Etc. Mounted Inside Enclosure , Visible And Accessible From Outside. The Enclosure Should Be Suitable For Following Capacity Dg Sets And Alternator. Noise Level Shall Be Less Than 75 Db At A Distance Of 1 Mtrs. Duly Certified By Authorised Agency Etc. Complete In All Respect Of Following Capacity : , E. ( A ) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 40Mm And Not Less Then 20Mm Pu Foam Upto Rating 100 Kva. ( B ) .Accoustic Glass Wool Wall Thickness Should Not Be Less Then 65Mm And Not Less Then Foam Upto Rating 250 Kva. ( C ) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 100Mm For Rating Above 250 Kva. , F. First Filling Of The Fuel Tank Shall Be Done By Contractor And The Prevailing Fuel Cost At That Time Shall Be Reimbursed To The Contactor By Department. , G. Servicing Of The Dg Set ( As Per Oem Guidelines ) During The Dlp Period Shall Be Done By Contractor Including All Consumables, Actual Charges Shall Be Reimbursed To The Contractor By Department / Client Complete In All Respect. , H.Oem Must Have Bis Certificate And&Shall Have Submitnabl / Cpri / Erda / Cpcb Standards Approved Lab Typetest Reportsbefore Execution As Requiredcompleteinallrespect.Allasperpreapprovedbyengineerincharge. Foradditionaltechnicalparametersofproducts / Annexure A Attached. , Radiator Cooled & Turbo Charged / Ac 160 Kva At 0.8 Pf 415V 50Hz 3-? , Dg Set ( 160 Kva ) , Supply , Installation, Testing And Comissioning Ofauto Main Failure ( Amf ) Panel Fabricated From Crca Sheet Steel 2 Mmthick , Powder Coated Finish , Engine Start & Stopcommands, Control Relays , Ammeter & Voltmeterwith Selector Switches, Control & 2 Nos 4 Pole Power Contactors With 2 No. Of Required Size 4 Pole Mccb, Timers, Electronic Hooter , Visual & Alarm Indication For Faults, Ups, Operator Interface Panel Complete In All Respect Suitable For Following Capacity Dg Sets. Oem Must Have Bis Certificate And& Shall Have Submitnabl / Cpri / Erda Lab Type Test Reports Before Execution As Required Complete In All Respect.All As Per Pre Approved By Engineer In Charge. Foradditionaltechnicalparamet .Plc Based 160 To 200 Kva , Providing & Laying Xlpe Insulated As Per Is:7098 / Ii / 85 H.T.Cable As Per Pwd Specification For Electrical Works For Working Voltage 33 K.V. ( E ) In Existing Rcc / Hume / Stoneware / Pvcpipe / Openduct / Cabletrenchwith Filling Of Excavated Earth In Trench, On Existing Cable Trays Or On Surface Etc.Including Making Necessary Connection, Testing Etc.As Required Of Size As Per Points ( A ) , ( B ) , ( C ) Mentioned Below:- ( A ) Material :- H4- Gradealuminium Conductor Of Purity >99.6 %& As Peris:1554 P-I / Is :7098 P - I ( B ) Conductorshallhaveelectrolyticaluminium Confirming To Is 8130, Is 3975-1999For Armouring Of Cables , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities Forcables .All Above As Per Pre Approved By Engineer In Charge.For Additional Technical Parametersofproducts / Work , Refer Annexure A Attached. 3 Core 300.0 Sq.Mm , Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit As Per Pwd Specification For Electrical Works Suitable For 11 Kv / 33 Kv Cable With Required Components, Prepration Of Cable Ends. Type Test Report Should Be As Per Is13573:2011 Which Covered All Sequence For Table 2 For Termination Kit And Table 3 For Streightthrough Joint Inclusive Thermal & Dynamic Short Circuit Test, Humidity Test, Soil Fog Test. Crosslinking Shall Be Done Out Side Factory With E- Beam / Peroxide Technology. Extrusion Process Shall Be In House Oem Within Same Vicinity. Oem Test Lab Should Be As Per Iso 9001:2015 & 14001 : 2015 & Reports Submitted To Engineer In Charge Including Testing Etc. As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached . 11 Kv End Termination Kit Outdoor Type 3 Core 240 / 300Sq.Mm , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured / Armouredaluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Worksin Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench, On Existing Cable Trays Or On Surface Etc.Including Making Necessary Connection, Testing Etc. As Required Of Size Andas Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Gradealuminium Conductor Of Purity >99.6 %& As Peris:1554 P-I / Is :7098 P - I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures . ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities Forcables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted. Allaboveasperpreapprovedby Engineerincharge. Foradditionaltechnicalparameters Of Products / Work Attached . Refer Annexure A , 185.0 Sq. Mm 3.5 Core Armoured Cable , 50.0 Sq. Mm 3.5 Core Unarmoured Cable , Additiomn:-H-Scheduleinstallation Cost With Other Necessary Fitting / Accessories Including Pedestal / Foundation, Gi / Copper Earthing & Stripsetc. Required Forsmooth Operation / Functioning For The Transformer Anddg Set. , Less:-Rebate For Buy Back And Taking Away The Old Working 100Kva Transformer From Site ( Head Office, Jaipur )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Apr-2022 Corrigendum for Single Envelop Other 20-04-2022

Key Value

Document Fees
INR 2360 /-
EMD
INR 247560.0 /-
Tender Value
INR 1.23 Crore /-

BOQ Items

Name of Work: Supply Installation testing & Commissioning ofTransformer Substation(250 KVA) & DG Set (125 KVA) atGharsana, Raisingnagar & HeadOffice RSWC JAIPUR.
Sl. No. Item Description
1TRANSFORMERSUBSTATIONS -250 KVA
2S I T C of star Aluminium wound distribution of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026- 1977 & lossesas defined as per IS 1180 part I 2014. including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All asperpreapprovedbyEngineerincharge. Foradditionaltechnical parameters of products/ work , referAnnexure "A" attached. 250 KVA with Off -LTC (+5% to - 10% @ 2.5%)
3Supply , Installation, Testing and Comissioning of 11KV, 630 A, 25 kA / 1 Sec, SF6 / VCB Indoor type panel HT board, free standing motor operated & withdrawaltypefabricatedfrom2mmthickCRCAsheetsteel,With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio ( 15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/v3) , Fuses , IP42 Protection, 4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection ( Highoiltemperature,Buchholzprotection,highwindingtemperature), power pack 2 x 12 V,etc complete in all respect Ready To Use(RTU),OEM Must have BIS certificate and&shall have submitNABL / CPRI / ERDA lab type test reportsbefore execution complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work.
4Supply , Installation, Testing and Comissioning of factory made11 KV, 630 A, 20kA / 3 sec, Out door Extensible type IP54 for panel & IP67 for main circuits Ring main unit (RMU) IEC 62271-200in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuitbreaker with over load, Earth fault, short circuit relay, copper bus bar, bus support and insulation marerial epoxy resin,ring core protection & metering CT, Auxiliary relay for WTI, OTI ,Bucholz alarm & trip along with annuciator panel, master trip relay, mechanical ON / OFF /Earth indication, Voltage presence indicator, Shunt trip coil, 24 V DC power pack, Digital multi function meter, with Bus PT panel with 3 Nos single phase voltage transformers of the ratio 11kV/v3 / 110 V/v3, 25 VA, Class 1.0 with HT fuses in the primary and MCB on the secondary side, Voltmeter with selector switch, R Y B phase indication, Anti reflex operating handle, right angle boots etc. OEM Must have BIS certificate and&shall have submitNABL / CPRI / ERDAlab tpye test reportsbefore execution as requiredcompleteinallrespect.AllasperpreapprovedbyEngineerin charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure "A" attached .
5Supply,Installation,Testing andComissioning of1 no.VCB/SF6 circuit breaker coupled with existing extensible type RMUwith over load, Earth fault, short circuit relay, copper bus bar, Ring core protection CT 2.5 VA, 10P10 as per transformer rating, mechanical ON / OFF /Earth indication, Voltage presence indicator, Anti reflex operating handle, right angle boots etc. as required complete in all respect. All as per pre approved by Engineer in charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure "A" attached.
6SupplyandFixingofISO/BIScertifiedmadeaccessoriesof Transformer above 500 KVA Rating i.e. Winding temperature indicator (WTI ), Oil temperature indicator ( OTI ) , Magnetic Oil level Gauge ( MOG), Bucholz relay with Alarm & trip Contacts & Marshalling Box including making connection & testing etc as required complete in all respect. Appropriate OEM test reports of all items shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work,referAnnexure "A" attached.
7Supply&InstallationofD.P.StructureWithAIRBREAKSWITCHhaving following specifications:- All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . DP : Double pole structure on 2 no ISMB 150 x 100 mm,10 mtr high using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator, GI pipe of suitable length for operation. DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators.LA:3piecenonlinearresistortype.lightingarrestorofapprovedmake suitable for 3 wire, 11kv Overheadline with rated voltage of 9kvrms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required.6.GENERAL:Thegoshallbeoperatedbyhandoperatedliver properly earthed with provision for locking mounted at 3’
8DG SET (160 KVA)
9Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H
10A.1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .
11B.AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine&AlternatormountedonacommonbaseFrame& coupled through a flexible coupling or close coupled
12C. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, with protection and tripping of DG set against temperature of more than 50 degree centigrade
13D. Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter,Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :
14E. (A)Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (B).Accoustic glass wool wall thickness should not be less then 65mm and not less then foam upto rating 250 KVA.(C)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA.
15F. First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.
16G. Servicing of the DG set (as per OEM guidelines) during the DLP period shall be done by contractor including all consumables,actual charges shall be reimbursed to the contractor by department/client complete in all respect.
17H.OEM Must have BIS certificate and&shall have submitNABL / CPRI / ERDA/ CPCB standards approved lab typetest reportsbefore execution as requiredcompleteinallrespect.AllasperpreapprovedbyEngineerincharge. Foradditionaltechnicalparametersofproducts/ Annexure "A" attached.
18Radiator Cooled & Turbo Charged /AC 160 KVA at 0.8 pf 415V 50Hz 3-?
19DG SET (160 KVA)
20Supply , Installation, Testing and Comissioning ofAuto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets. OEM Must have BIS certificate and& shall have submitNABL / CPRI / ERDA lab type test reports before execution as required complete in all respect.All as per pre approved by Engineer in charge. Foradditionaltechnicalparamet .PLC based 160 to 200 KVA
21Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 33 K.V.(E) in existing RCC / Hume / Stoneware/PVCpipe/openduct/cabletrenchwith filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc.as required of size as per points (a), (b), (c)mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminium confirming to IS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables .All above as per pre approved by Engineer in charge.For additional technical parametersofproducts/ work , refer Annexure "A" attached. 3 core 300.0 Sq.mm
22Providing & making heat shrinkable type indoor/outdoor/straight through terminations/joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached . 11 KV End Termination Kit Outdoor type 3 core 240/300Sq.mm
23Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminium cable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume/ Stoneware/ PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted. Allaboveasperpreapprovedby Engineerincharge. Foradditionaltechnicalparameters of products/ work attached . refer Annexure "A"
24185.0 Sq. mm 3.5 core Armoured Cable
2550.0 Sq. mm 3.5 core Unarmoured Cable
26ADDITIOMN:-H-SCHEDULEInstallation Cost with other necessary fitting/accessories including pedestal / foundation, GI/Copper earthing & Stripsetc. required forsmooth operation/ functioning for the Transformer andDG set.
27LESS:-Rebate for buy back and taking away the old working 100KVA Transformer from site (Head Office, Jaipur)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail