Road Transport and Highways Government Departments Closing in 0 days TDR #31677239

Construction Of Bus Stand At Junagarh, Dist-Kalahandi.

Issued by Government Departments · junagarh, Odisha
Tender Value
1 Crore
Estimated cost
Bid Submission
11 Apr 2022
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
junagarh → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Bus Stand At Junagarh, Dist-Kalahandi.

BOQ

Name of Work:Construction of OSRTC Bus Stand at Junagarh,Dist-Kalahandi.
Sl. No. Item Description
1MAIN BUILDING
2Earth Work in hard soil or gravelly soil within 50m.Intial Lead and1.5m.Initial Lift including rough dressing and breaking clods to maximum 5cm.to 5cm. And Laying and Layers not exceeding 0.3m. In depth.
3Providing Anti-termite treatement to foundation trench and inside of floor including labour and materials etc, complete.
4Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
5Providing and Layingplaincement concrete 1: 4: 8 .( 1 cement: 4 sand : 8 stone Aggregate 40mm nominal size ) As levellingcourse infoundation and plinthetc. complete all depth and height.
6F.A brick masonary work in cement mortar (1:6) using F.A bricks of 23cm x 11cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN FOUNDATION & PLINTH
7F.A brick masonary work in cement mortar (1:6) using F.A bricks of 23cm x 11cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN SUPERSTRUCTURE.
8GROUND FLOOR
9FIRST FLOOR
10F.A brick masonary work in cement mortar (1:4) using F.A bricks of 23cm x 11cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN SUPERSTRUCTURE.
11GROUND FLOOR
12Providing and Laying reinforce cement concrete M-20 Grade20 mm nominal size HBG chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement) anddirection of Engineer-in-charge.
13GROUND FLOOR
14FIRST FLOOR
15Cutting, bending , binding and placing in position of uncoated HYSD bar reniforcement as per drawing for R.C.C work including the cost of binding wire, steel,labour and tools etc.
16GROUND FLOOR
17FIRST FLOOR
18Rigid & smooth centering and shuttering false,levelled works and dismantling , then after casting including cost of materials complete for plinth band and column footing.
19GROUND FLOOR
20Rigid and smooth centering and shuttering of RCC works including false worksof Lintels including removal of form work at all depth and heights.
21GROUND FLOOR
22Rigid and smooth centering and shuttering of RCC works including false works griders,beams,column including removal of form work at all depth and heights.
23GROUND FLOOR
24FIRST FLOOR
25Rigid and smooth centering and shuttering of RCC works including false works roof slabs,Landing, balconies, projecting sun shades and chajja etc including dismantling them after casting including cost of materials etc complete.
26GROUND FLOOR
27Rigid and smooth centering and shuttering of RCC works including false works of RCC walls and fins etc including removal of form work at all depth and heights.
28GROUND FLOOR
2916mm thick cement plaster in cement mortar 1:6 including necessary scaffolding curing etc. all complete at all depth and height.
30GROUND FLOOR
31FIRST FLOOR
326mm thick cement plaster in cement mortar 1:4 to RCC surfaces finished smooth including closed deep chiping and slurry treatment with necessary scaffolding, curring etc all complete.
33GROUND FLOOR
34FIRST FLOOR
3512mm cement plaster in cement mortar 1:6 including necessary scaffolding curing etc. All complete at all depth height for out side portion wall.
36GROUND FLOOR
37FIRST FLOOR
38Providing and applying priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc. complete.
39GROUND FLOOR
40FIRST FLOOR
41Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. (ASIAN (ULTIMA) / BURGER (Anti Dust) / and DULUX (Weather Shield).[NSWI]
42GROUND FLOOR
43FIRST FLOOR
44Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.(N.S.W.I)
45GROUND FLOOR
46Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application.(ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). [NSWI]
47GROUND FLOOR
48Supplying, fitting and fixing of M.S grills, M.S angles including cost of labour materials transportation etc.complete.
49GROUND FLOOR
50Enamel painting two coats with cost of all material, labour, T&P etc complete.
51GROUND FLOOR
52One coat of priming with approved primer over new wood work. with cost of all material, labour, T&P etc complete.
53GROUND FLOOR
54Supplying, Fitting & Fixing of 10 mm thick Digital glazed Vitrified Tile in floor of size 600mm x 600mm of approved shade laid on leveled CC Course with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filling joints with epoxy grout (2mm) of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-Charge. (Tiles must be SOMANY, KAJURIA, NITCO, VARMORA and RAK). Per Sqm.
55GROUND FLOOR
56Providing, Fixing & Fitting Anti-skid CERAMIC floor tiles of 9mm thick of size 300mm x 300mm laid over 25mm Cement mortar (1:1) laid in proper slope and filling joints with epoxy grout (2mm) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect as per the direction of the Engineer-in-charge. (SOMANY, KAJARIA, NITCO, VARMORA & RAK). Per Sqm.
57GROUND FLOOR
58Providing, Fixing & Fitting Ceramic glazed tiles on wall of size 300mmx450mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect as directed by the Engineer-in-charge. (SOMANY, KAJARIA, NITCO, VARMORA & RAK). Per Sqm.
59GROUND FLOOR
60Supplying, fitting and fixing of Industrial chequertileon 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing etc complete including cost of tile, material, labour T & P etc complete.
61GROUND FLOOR
62Drip course mould plaster 1:4 including necessary scaffolding curing etc complete at all depth and height as per direction of site in charge.
63GROUND FLOOR
64Supplying,fitting & fixing of 4\"dia U.P.V.C. rain waterpipe with necessary fittings and all complete.
65GROUND FLOOR
66Supplying,fitting and fixing of F.R.P. door with frame including cost of all materials labour T & P taxes etc ,complete.
67GROUND FLOOR
682.5 cm thick grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips on new work including cost of labour, material, T&P etc. all complete.
69GROUND FLOOR
70Providing ,Fitting and Fixing of khondalite tile in wall on 12mm thick cement plaster 1:3 jointed with neat cement slurry mixed with pigments to match the shade of the tile in all complete.
71GROUND FLOOR
72MARKET COMPLEX
73Earth Work in hard soil or gravelly soil within 50m.Intial Lead and1.5m.Initial Lift including rough dressing and breaking clods to maximum 5cm.to 5cm. And Laying and Layers not exceeding 0.3m. In depth.
74Providing Anti-termite treatement to foundation trench and inside of floor including labour and materials etc, complete.
75Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
76Providing and Layingplaincement concrete 1: 4: 8 .( 1 cement: 4 sand : 8 stone Aggregate 40mm nominal size ) As levellingcourse infoundation and plinthetc. complete all depth and height.
77F.A brick masonary work in cement mortar (1:6) using F.A bricks of 23cm x 11cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN FOUNDATION & PLINTH
78F.A brick masonary work in cement mortar (1:6) using F.A bricks of 23cm x 11cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN SUPERSTRUCTURE.
79GROUND FLOOR
80Providing and Laying reinforce cement concrete M-20 Grade20 mm nominal size HBG chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement) anddirection of Engineer-in-charge.
81GROUND FLOOR
82Cutting, bending , binding and placing in position of uncoated HYSD bar reniforcement as per drawing for R.C.C work including the cost of binding wire, steel,labour and tools etc.
83GROUND FLOOR
84Rigid & smooth centering and shuttering false,levelled works and dismantling , then after casting including cost of materials complete for plinth band and column footing.
85GROUND FLOOR
86Rigid and smooth centering and shuttering of RCC works including false worksof Lintels including removal of form work at all depth and heights.
87GROUND FLOOR
88Rigid and smooth centering and shuttering of RCC works including false works griders,beams,column including removal of form work at all depth and heights.
89GROUND FLOOR
90Rigid and smooth centering and shuttering of RCC works including false works roof slabs,Landing, balconies, projecting sun shades and chajja etc including dismantling them after casting including cost of materials etc complete.
91GROUND FLOOR
92Rigid and smooth centering and shuttering of RCC works including false works of RCC walls and fins etc including removal of form work at all depth and heights.
93GROUND FLOOR
9416mm thick cement plaster in cement mortar 1:6 including necessary scaffolding curing etc. all complete at all depth and height.
95GROUND FLOOR
966mm thick cement plaster in cement mortar 1:4 to RCC surfaces finished smooth including closed deep chiping and slurry treatment with necessary scaffolding, curring etc all complete.
97GROUND FLOOR
9812mm cement plaster in cement mortar 1:6 including necessary scaffolding curing etc. All complete at all depth height for out side portion wall.
99GROUND FLOOR
100Providing and applying priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc. complete.
101GROUND FLOOR
102Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. (ASIAN (ULTIMA) / BURGER (Anti Dust) / and DULUX (Weather Shield).[NSWI]
103GROUND FLOOR
104Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.(N.S.W.I)
105GROUND FLOOR
106Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application.(ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). [NSWI]
107GROUND FLOOR
108Supplying, fitting and fixing of M.S grills, M.S angles including cost of labour materials transportation etc.complete.
109GROUND FLOOR
110Enamel painting two coats with cost of all material, labour, T&P etc complete.
111GROUND FLOOR
112One coat of priming with approved primer over new wood work. with cost of all material, labour, T&P etc complete.
113GROUND FLOOR
114Supplying, Fitting & Fixing of 10 mm thick Digital glazed Vitrified Tile in floor of size 600mm x 600mm of approved shade laid on leveled CC Course with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filling joints with epoxy grout (2mm) of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-Charge. (Tiles must be SOMANY, KAJURIA, NITCO, VARMORA and RAK). Per Sqm.
115GROUND FLOOR
116Supplying, fitting and fixing of Industrial chequertileon 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing etc complete including cost of tile, material, labour T & P etc complete.
117GROUND FLOOR
118Drip course mould plaster 1:4 including necessary scaffolding curing etc complete at all depth and height as per direction of site in charge.
119GROUND FLOOR
120Supplying,fitting & fixing of 4\"dia U.P.V.C. rain waterpipe with necessary fittings and all complete.
121GROUND FLOOR
1222.5 cm thick grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips on new work including cost of labour, material, T&P etc. all complete.
123GROUND FLOOR
124SEPTIC TANK
125Earth Work in ordinary soilwithin 50m.Intial Lead and1.5m.Initial Lift including rough dressing and breaking clods to maximum 5cm.to 5cm. And Laying and Layers not exceeding 0.3m. In depth.
126GROUND FLOOR
127Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
128GROUND FLOOR
129Providing and Layingplaincement concrete 1: 4: 8 .( 1 cement: 4 sand : 8 stone Aggregate 40mm nominal size ) As levellingcourse infoundation and plinthetc. complete all depth and height.
130GROUND FLOOR
131F.A brick masonary work in cement mortar (1:6) using F.A bricks of 25cm x 12cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN FOUNDATION & PLINTH
132GROUND FLOOR
133F.A brick masonary work in cement mortar (1:4) using F.A bricks of 25cm x 12cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN FOUNDATION & PLINTH
134GROUND FLOOR
135Providing and Laying reinforce cement concrete M-20 Grade20 mm nominal size HBG chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement) anddirection of Engineer-in-charge.
136GROUND FLOOR
137Cutting, bending , binding and placing in position of uncoated HYSD bar reniforcement as per drawing for R.C.C work including the cost of binding wire, steel,labour and tools etc.
138GROUND FLOOR
139Rigid and smooth centering and shuttering of RCC works including false works roof slabs,Landing, balconies, projecting sun shades and chajja etc including dismantling them after casting including cost of materials etc complete.
140GROUND FLOOR
14116mm thick cement plaster in cement mortar 1:6 including necessary scaffolding curing etc. all complete at all depth and height.
142GROUND FLOOR
14325mm thick A.S.Flooring with cement concrete 1:2:4 including punning using 12mm.size hard granite chips with cost conveyance, royality, watering & curing etc. complete.
144GROUND FLOOR
14512mm thick cement plaster 1:4 overbrick work with cement punning for skirting.with cost conveyance, royality, watering & curing etc. complete.
146GROUND FLOOR
147Providing, fitting ,fixing of 4 cmsize K.B brick khoa with proper laying and compaction etc including cost ofall materials ,labour T& P etc complete.
148GROUND FLOOR
149INSPECTION CHAMBER
150Earth Work in ordinary soilwithin 50m.Intial Lead and1.5m.Initial Lift including rough dressing and breaking clods to maximum 5cm.to 5cm. And Laying and Layers not exceeding 0.3m. In depth.
151GROUND FLOOR
152Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
153GROUND FLOOR
154Providing and Layingplaincement concrete 1: 4: 8 .( 1 cement: 4 sand : 8 stone Aggregate 40mm nominal size ) As levellingcourse infoundation and plinthetc. complete all depth and height.
155GROUND FLOOR
156F.A brick masonary work in cement mortar (1:6) using F.A bricks of 25cm x 12cm x 8cm having crushing strength not less than 35kg per sqcm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete.IN FOUNDATION & PLINTH
157GROUND FLOOR
158Providing and Laying reinforce cement concrete M-20 Grade20 mm nominal size HBG chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement) anddirection of Engineer-in-charge.
159GROUND FLOOR
160Cutting, bending , binding and placing in position of uncoated HYSD bar reniforcement as per drawing for R.C.C work including the cost of binding wire, steel,labour and tools etc.
161GROUND FLOOR
162Rigid & smooth centering and shuttering false,levelled works and dismantling , then after casting including cost of materials complete for plinth band and column footing.
163GROUND FLOOR
16416mm thick cement plaster in cement mortar 1:6 including necessary scaffolding curing etc. all complete at all depth and height.
165GROUND FLOOR
16612mm thick cement plaster 1:4 overbrick work with cement punning for skirting.with cost conveyance, royality, watering & curing etc. complete.
167GROUND FLOOR
168SITE DEVELOPMENT(DISMENTALLING)
169Dismentalling of brick/stone masonary in cement motar including stacking theuseful materials for reuse and removing the debries with in 50 mtr lead.
170GROUND FLOOR
171Dismentaling of R.C.C. columns ,beams ,slab ,staircase,landing and lintels including stacking the useful materials for reuse within 50 mtr.lead.
172GROUND FLOOR
173AREA CONCRETING (CARRAIGE WAY)
174Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
175GROUND FLOOR
176Providing and Layingplaincement concrete 1: 4: 8 .( 1 cement: 4 sand : 8 stone Aggregate 40mm nominal size ) As levellingcourse infoundation and plinthetc. complete all depth and height.
177GROUND FLOOR
178Providing and Laying reinforce cement concrete M-20 Grade20 mm nominal size HBG chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement) anddirection of Engineer-in-charge.
179GROUND FLOOR
180Cutting, bending , binding and placing in position of uncoated HYSD bar reniforcement as per drawing for R.C.C work including the cost of binding wire, steel,labour and tools etc.
181GROUND FLOOR
182Rigid & smooth centering and shuttering false,levelled works and dismantling , then after casting including cost of materials complete for plinth band and column footing.
183GROUND FLOOR
184Filling bitumen and cement and jute fibre in expansion joints inclusive of cost of materials,bitumen and cement proportion ( 3:1) including cleaning before pouring 12 mm to 25 mm and 15 cm depth.
185GROUND FLOOR
186AREA PAVING
187Earth Work in ordinary soilwithin 50m.Intial Lead and1.5m.Initial Lift including rough dressing and breaking clods to maximum 5cm.to 5cm. And Laying and Layers not exceeding 0.3m. In depth.
188GROUND FLOOR
189Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
190GROUND FLOOR
191Providing and laying 80 mm thick Factory made cement concrete interlocking Paver block of M40 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge.
192GROUND FLOOR
193Providing and Layingat near ground level factory made kerb stone of M20 graded ( 450 x 300 x 150mm ) cement concrete in position to the required line,level and curveture,jointed with cement mortar 1:3 including making joints with or without groove(thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete etc. as per the direction of EIC.(Precast CC kerb stone shall be approved by EIC)
194GROUND FLOOR
195FURNITURE
196CABIN TABLE WITH DISCUSSION TIP SIZE : 2400X900X750MM HT, SIDE TABLE: 1500X450X750,Table Top: 25mm Thick pre laminate particle board with 2mm PVC edge lipping on all exposed edges. Support:25mm thick pre laminated gable ends. Wiremanagement: 400mm alluminium flip up with metal cable tray with vertical wire entry.Office desk
197Anatom Medium Back Chair, Mesh Back, With Headrest,Single lock Synchro Mechanism,Adjustable Lumber support, One Way Adjustable Arm(Height), Nylon Base-Executive Chair
198Supplying, fitting and fixing of Stainless steel seating benches etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect-Steel 4 seater waiting chair
199Providing & fixing of Wardrobe Sliding type of size (1800x600x2000) Kismo make : Maple.
200LAND SCAPING
201Surface dressing of the ground including removing Vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish lead upto 50m (at least 5m away from the dressed area). (Provisional)
202Supplying and stacking & speareding of good earth at site including royalty and carrage up to 5 KM (earth measured in stacks will be reduced by 20% for payment) 300mm th. (Provisional)
203Supplying and stacking sludge at site including royalty and carrage up to 5 KM (sludge measured in stacks will be reduced by 8% for payment). (Provisional)
204Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation, breaking clods and fine dressing the ground including all materials and labour complete as per direction of Engineer-In-Charge. (Provisional)
205Provision of soft surfaces such as grass lawns in between the open spaces. (Provisional)
206Planting of Ornamental spp (30\"x30\", 6\"x7\" Height Poly pack.) Digging pits removing all unserviceable materials and dumping outside the working area as shown by the engineer incharge .Supply and filling the same pits with good soil and well decomposed cow-dung manure mixture of ratio 4:1 and required quantites of fertilizer and pesticides and supply and planting with specified saplings as per the instruction of engineer in charge and taking up maintenance work like watring ,weeding apply of fertilizer, pesticides etc including cost of men, matrial , tools,tackles all complete.
207Slow growing ornamental species. (Provision)(i.e. Asoka (sarca asoka), Baula (mimussops elengii), Bottle brush (callistemin lanceolatum), Neem (azadirchta indica), Karanj (pangamea pinnata), Debdaru (polyalthia longifolia), Aonla (embelica officinalis), Sunari (cassia fistula) & Kanchan (bauhinia variegate)
208Shrub species (i-Local species).(Provision)(i.e. Mandar (hibiscus rosasinesis), Tagar (tabarnae montana coronaria) , Kaniar (thevetia spp), Karabira (nerium oleander)
209Creepers/ Climbers/ Ground covers.(Provision)(i.e. Jui(jasminum offcinale), Jai (jasminum pubescence), Madhumalati (quuisquilis indica)
210Supplying fitting fixing of UPVC (SCH-80) pipe including all cost. (Provision)
211i) 25 mm dia
212ii) 40 mm dia
213Fitting Fixing of PVC Ball Valve. (Provision)
214i) 25 mm dia
215i) 40 mm dia
216Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. (Provision)
21715mm dia CP Bib cock (Plaza/zigma/Amber/Delux Make) (Provision)
218RCC DRAIN
219Earth Work in ordinary soilwithin 50m.Intial Lead and1.5m.Initial Lift including rough dressing and breaking clods to maximum 5cm.to 5cm. And Laying and Layers not exceeding 0.3m. In depth.
220GROUND FLOOR
221Filling sand in foundation and plinth watering, ramming, consolidating and dressing labours tools,taxes etc all complete as per specification and direction of E.I.C.
222GROUND FLOOR
223Providing and Layingplaincement concrete 1: 4: 8 .( 1 cement: 4 sand : 8 stone Aggregate 40mm nominal size ) As levellingcourse infoundation and plinthetc. complete all depth and height.
224GROUND FLOOR
225Providing and Laying reinforce cement concrete M-20 Grade20 mm nominal size HBG chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement) anddirection of Engineer-in-charge.
226GROUND FLOOR
227Cutting, bending , binding and placing in position of uncoated HYSD bar reniforcement as per drawing for R.C.C work including the cost of binding wire, steel,labour and tools etc.
228GROUND FLOOR
229Rigid & smooth centering and shuttering false,levelled works and dismantling , then after casting including cost of materials complete for plinth band and column footing.
230GROUND FLOOR
2316mm thick cement plaster 1:4 overbrick work with cement punning for skirting.with cost conveyance, royality, watering & curing etc. complete.
232GROUND FLOOR
233INTERNAL P.H.
234Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.
23540 mm dia Pipe (CPVC)
23625 mm dia Pipe (CPVC)
23720mm dia Pipe (CPVC)
23815 mm dia Pipe (CPVC)
239Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification.
240250 mm thick wall (10\")
241Cutting hole in R.C.C floors and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof.
242Detail cost per I hole of size (15cmX15cmX25cm)
243Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete.
244Detail cost per 1 meter
245Providing and fixing wall face Unplasticised rigid PVC soil,waste and rain water pipes conforming to IS : 13295,TYPE-Aincluding jointing with seal ring confirming IS: 5382,leaving 10 mm gap for theramal expansion, including testing as per specification etc. complete.110mm dia. rigid UPVC Single socket SWR Pipes
246110mm dia. rigid UPVC Single socket SWR Pipes
247Providing and Laying in trenches UnplasticisedPVC pipes conforming to IS : 4985-2000 and specials of the following outside diameter for all classes, including jointing with supply of approved solvent cement by heat application method including testing as per specification etc. complete.110 mm dia. rigid UPVC Pipes,Class-3 (0.60 mpa).
248110 mm dia rigid UPVC pipe ,Class-3 (0.60 mpa)
249Providing and Laying in trenches UnplasticisedPVC pipes conforming to IS : 4985-2000 and specials of the following outside diameter for all classes, including jointing with supply of approved solvent cement by heat application method including testing as per specification etc. complete.160 mm dia. rigid UPVC Pipes,Class-3 (0.60 mpa).
250160 mm dia rigid UPVC pipe ,Class-3 (0.60 mpa)
251Fixingfloor traps of the following nominal diameter of outlet of self cleaning design withscrewed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification.
252110mm dia Inlet & Outlet floor traps PVC SWR type
253Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion .
254110 mm dia Single Junction with door PVC SWR type
255Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion .
256110 mm dia Plain Bend PVC SWR type
257Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion .
258110 mm dia Cowel PVC SWR type
259Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion .
260110 mm dia Bend with door PVC SWR type
261Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to JAQUAR MAKE of brand code CNS-WHT-553SN and of viteros china make seat cover fixing to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. ( With Seat and cover) (White Vitreous china wash down water closet E.W.C)
262Water closet European type W.C pan with seat cover (JAQUAR MAKE)
263Providing and fixing controlled flush, low level cistern made of vitreous china conforming toCNS-WHT-353 N / 353 S / 755 ( JAQUAR MAKE ) with all fittings and fixtures complete.
264Cistern 10 Ltr capacity , CNS-WHT-353N/353S/755 (JAQUAR MAKE)
265Fixing Wash Basins with hole for pillar taps conforming to IS 2556 : Part 4-2004/ JAQUAR MAKE with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. ( Vitreous china flat back Wash Basin 550 x 400 x 200 mm ( CNS-WHT-801- JAQUAR MAKE )
266Vitreous china flat back wash basin 550 x 400 x 200 mm (CNS-WHT-801-JAQUAR MAKE)
267Fixing of U.P.V.C Ball Valve of 25 mm diameter conforming to the following nominal sizes with wheel as per specification complete.(solvent welded with metal ball)as per the direction of EIC.
26825 mm dia U.P.V.C Ball Valve
269Fixing of U.P.V.C Ball Valve of 40 mm diameter conforming to the following nominal sizes with wheel as per specification complete.(solvent welded with metal ball)as per the direction of EIC.
27040 mm dia U.P.V.C Ball Valve
271Fixing of Brass Screw-down Two way Short Body Bib Cocks ( Taps ) polished bright conforming to ( JAQUAR MAKE ) with CP flange and CP extension piece ofthe following nominal sizes as per specificationcomplete. (Delux Head& highquality) ( CON-041KN-JAQUAR MAKE)
27215mm dia Two way Short body bib cock (CON-041KN-JAQUAR MAKE)
273Fixing of Brass Screw-down Long Body Bib Cocks ( Taps ) polished bright conforming to ( JAQUAR MAKE ) with CP flange and CP extension piece ofthe following nominal sizes as per specificationcomplete. (Delux Head& highquality)(CODE CON-107KN-JAQUAR MAKE)
27415mm dia Long body bib cock (CON-107KN-JAQUAR MAKE)
275Fixing of C.P Screw-down Angular Stop Cocks conforming to of the following nominal sizes as per specification complete. (Deluxe Head& high quality) (A.R-2013,SL NO-3.2.16)
27615mm dia C.P Angular cock
277Fixing of Brass C.P Screw-down Consealed Stop Cocks conforming to of the following nominal sizes as per specification complete. (Deluxe Head& high quality) (A.R-2013,SL NO-3.2.16)
27815mm dia C.P Consealed Stop Cock
279Fixing Chromium Plated BrassShower rose conforming to OHS-1985 (JAQUAR MAKE)including polishing all complete as per specification. (Deluxe Head & Heavy quality)
28015o mm dia 15 - 20 mm C.P Brass Shower rose(OHS-1985 - JAQUAR MAKE)
281Fixing Chromium Plated Arm of 15mm or 20 mm inlet conforming to (Shower arm casted 190 mm long light body round shape for wall mounted showers with flange ( SHA - 477 - JAQUAR MAKE )including polishing all complete as per specification.(Deluxe Head &Heavy quality)
28215 mm x 225 mm long CP Shower arm (SHA - 477 - JAQUAR MAKE)
283Fitting,Fixing of Health faucetconforming to ( Hand shower Health faucet ABS Body with 1.2 meter long PVC tube & wall hook (ALD-IVY-583 and ALD-BLK-583-JAQUAR MAKE)including polishing all complete as per specification.
284Health Faucet ( ALD-IVY- 583 & ALD-BLK-583-JAQUAR MAKE )
285Fixing Chromium Plated Soap dish holder complete with Chromium Plated brass brackets fixed to P.V.C plugs with Chromium Plated brass screwsas per specification.(JAQUAR MAKE,BRAND ACN-1131N)
286Soap dish holder(CAN-1131N-JAQUAR MAKE)
287Fixing standard sized CP Glass-Shelf with Chromium Plated brass brackets and guard rails complete, fixed to wooden plugs with Chromium Plated brass screws as per specification.(600 mm long glass shelf-JAQUAR MAKE,BRAND ACN-1171N)
288600x120 mm Glass shelf (ACN-1171N-JAQUAR )
289Fixing standard sized Towel rail of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.(Single Towel rail 600mm long)(ACN-1111NM-JAQUAR)(Heavy quality)
290CP Towel Rail ( ACN-1111 NM-JAQUAR )
291Fixing standard sized Chromium Plated brass towel ring of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.(Round Towl Ring with round Flange)(ACN-1121 BN-JAQUAR)
292CP Towel Ring (ACN-1121 BN-JAQUAR MAKE)
293Fixing 600 mm x 450 mm Bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification.(AR-2013,SL. NO.-3.4.26)
294Bevelled edge mirrior
295Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the E.I.C .
296Double Layer Cylinderical Vertical water storage tanks
297Supplying and installation of storage water cooler cum purifier on floor base having 3 syage advanced purification process (VU based both for cooling and purifying system).The storage tank capacity 80L,cooling capacity 60LPH,water flow rate 1.5 L,the body made up of ss304 and size 640X450X1350mm.MODEL-AG Green Pure Chill 80SS UV (HSN code-8418) (N.S.W.I)
298COOLER CUM PURIFIER
299EXTERNAL P.H.
300Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of ownrigs with its accessories, tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).
301a) Labour for drilling
302Cost of P.V.C (A S T M SCHEDULE-80)pipe 200 mm dia (ASTM D-1785) Make-Oriplast, Hariplast
303a)P.V.C ASTM (SCHEDULE-80) PIPES
304Lowering the 200mm dia size PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position,including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials,tools and plant etc.complete and keeping the top of the casing pipe threaded including plugging tubewells to prevent entry of foreign materials from above.
305a)Lowering of 200mm dia P.V.C casing pipes
306Cleaning and developing the 200mm dia tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge.
307a) By DTH/Rotary Rig
308Submersible Pump Set with the cost of Motor
3091.5HP Single phase(32 Mtr. Head) Model (GP121507)
310Control Panel Board (C&S)
311Upto 3HP Single Phase
312HDPE Pipes 32/40 mm ( High Density PVC pipes inner dia 32mm, outer dia 40mm, 6Kg/ Cm Sqr. With IS specification
313a) Detail cost per 1 meter
314Steel Rope with PVC coated 6mm
315a) Detail cost per 1 meter
316Finolex/L&T/BCH Cable 4 Sq. mm( 3core copper wire flat cablePVC insulation)
317a) Detail cost per 1 meter
318Accessories like Nipple, Bore cover,MS clamp, Nut Bolt,Stainless steel nipple, Short piece, GI bend, Socket etc. complete.
319a) Detail cost per 1 Set
320Installation Charges including transportation
321a) Charge per 1 Set
322INTERNAL ELECTRIFICATION
323LT CABLE-Supply and laying of 1100 V grade, (XLPE/PVC) insulatedaluminium conductor, armouredpower cable as per specifications.The cables shall be laid in cable trenches or buried directly underground or on cable trays. The cost of the cable trays or ladders, excavation and back filling of trenches will be measured separate. The unit cost of the cable shall include clamps, fasteners, saddles, tags etc. as required for proper instllation.
3244C x 16 Sqmm, Al. cable
3254C x 6 Sqmm, Cu. cable
3263C x 6 Sqmm, Cu. cable
327END TERMINATION-Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
3284 x 16 sq.mm
3294 x 6 sq.mm(CU)
3303 x 6 sq.mm
331DISTRIBUTION BOARDS-Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.
3324WAY 7 SEGMENTTPNMCB DB. CONSIST OG 63A TPN MCBas a Incomer , 40A DB RCCB as a sub incomer (3 Nos) and also 12 Nos Sp MCb as a outgoing.for LDB + PDB
3338WAY (2+ 6) SPN DOUBLE DOOR
334PERFORATED TYPE CABLE TRAY-Supply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 2 mm. Support sizes similar to ladder type trays
335Size of Cable Tray :150 mm x 50 mm
336FITTINGD & FIXTURE-Supply Installation, testing and commissioning of thefollowing lighting luminaires including all necessary accessories like electronic driver, holder, control gear, fixing accessories, down rod, chain suspender, supporting arrangements, clamps, as per the site requirments.
337Supply , installationtesting and commissioning of 20Watts LED tube wall mounted/Surface typelight fitting with all accessories as required.
338Supply , installationtesting and commissioning of 10Watts LED surface mounted type light fitting with all accessories.
339Supply , installationtesting and commissioning of 10Watts wall mounted LED bulb with all accessories as required.
340Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan of Havells velocity/CROMPTRON JURA Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge .(With fan Regulator)
341Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers (Make-Havells/almonard/cromptron makeor any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
342SOCKETS
343Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 6 /16 A modular socket outlet and 16 A modular switch, connections etc. as required.
344Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 6A modular socket outlet and 6 A modular switch, connections etc. as required.
345Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1nos of 6 pin 16A modular socket outlet controlled by 1no of 16 A modular switch, connections etc. as required.-(UPS)
346CIRCUIT WIRING
3472 Runs of 2.5 sqmm multi strand FRLS insulated copper conductor wire in 25 mm dia FRLS PVC conduit along with 1 Run of 1.5 sq.mm multi strand FRLS insulated copper earth wire with all necessary accessories as required.(lighting & small power)
3482 Runs of 4 sqmm multi strand FRLS insulated copper conductor wire in 25 mm dia FRLS PVC conduit along with 1 Run of 2.5 sq.mm multi strand FRLS insulated copper earth wire with all necessary accessories as required.(Raw Power)
349POINT WIRING
350Point wiring of light, using 1100 volt grade, 2 Runs of 1.5 sqmm multi strand FRLS insulated copper conductor wire along with 1 Run of 1.5 sq.mm multi strand FRLS insulated copper earth wire, drawn in 19/20mm dia,2mm thick rigid FRLS PVC conduit in a concealed /open conduit system.The wiring shall be complete with all conduit and wiring accessories like deep junction boxes, collars, tees, bends, elbows, MS boxes, GI pull wires,clamps, spacers, screws, etc.The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screwsearthing ofall points using third core of the cable,DB to switch control will be measured as circuit wiring.The switch boxes shall be flush mounted in brick wall.The point wiring shall be as per specification. Group B
351Two light/fan/ex.fpoint controlled by one 6A switch or first light/fan/exf/cb point or group control.modular GROUP-b
352Three light/fan/ex.fpoint controlled by one 6A switch or first light/fan/exf/cb point or group control.modular GROUP-B
353PVC PIPES
354Supplying and fixing of 20mm FRLS PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
355Supplying and fixing of 25mm FRLSPVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
356UPS & INVERTER
357Supply and Installation of 2KVAUPS with suitable batteries for 90 Mins battery backup
358MISCELLENOUS ITEMS
359Rubber matISI approved 2m x 1m
360First aid kit( At Electrical Room)
361SERVICE CHARGES
362Arranging the required details from - duely making the formalities and arranging service of the installation with the projected charges and arranging required approval from the required government Electrical Inspectorate and permission for the energising the HT installation works. Also this item should include charges towards arranging temporary power supply for construction and making payments, monthly bills and renewal/upgrading temporary power supply.
363EXTERNAL ELECTRIFICATION
364LT CABLE-Supply and laying of 1100 V grade, (XLPE/PVC) insulatedaluminium conductor, armouredpower cable as per specifications.The cables shall be laid in cable trenches or buried directly underground or on cable trays. The cost of the cable trays or ladders, excavation and back filling of trenches will be measured separate. The unit cost of the cable shall include clamps, fasteners, saddles, tags etc. as required for proper instllation.
3653.5C x 70 Sqmm, Al. cable
366END TERMINATION-Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
3673.5C x 70 sq.mm
368EARTHING
369Supply, erection and testing of GI Plate earth electrode as per IS 3043 standards complete with 3 mtrs long, 40mm dia. GI pipe, 600 x 600 x 6mm size GI plate and 1 run of 40 x 6mm GI flat upto test link from plate earth electrode, watering funnel and necessary bolt & nuts. Complete with excavation and construction of 450mm x 450mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm cast iron / RCC cover with frame. The earth electrode shall be filled with the alternate layer of charcoal and salt. (For body Earthing)
370Supplying and laying 46 mm x 6 mm G.I earth strip ISI marked on surface or in recess for connection etc as required.
371Providing and fixing 8 SWG G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required
372FITTINGS & FIXTURE
373Supply Installation, testing and commissioning of thefollowing lighting luminaires including all necessary accessories like electronic driver, holder, control gear, fixing accessories, down rod, chain suspender, supporting arrangements, clamps, as per the site requirments.
374Supply & installation of 80W LED Streetlight Luminaire with a nominal system lumen output of 8000 lumens and a minimum system efficacy of 100 lm/W. System wattage should not exceed 72W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5700K and CRI of 70. Driver of the luminaire shall have PF>0.95. Product should be able to withstand surge protection up to 10 KV. The luminaire housing should be made of LM6 high pressure die cast Aluminium & toughened glass front cover. Product should be IP66 rated. Similar to Wipro make Skyline Neo \"LR07-981-XXX-57-XX\"(OR) EQUIVALENT MAKE.
375Supply & installation of 9.0mtr height Octagonal poles with Mat Finish with foundation bolt and nut etc with smart pack terminal Box (Mounting inside the base compartment of power. The cost is inclusive of 5Mtrs 8SWG wire. Make :BAJAJ / VALMART/WIPRO/UTKARSH/CG
3761.5 mtrs Single cross Arm bracketsuitable to the above pole
377MISCELLENOUS ITEMS
378Supply and installation of HT/LT Danger board as required by the CEA/ CEIG authorities.
379Supply and fixing of HT/LT cable route indicator (cast iron) made out of MS flat and angle iron
380Shock treatment chart laminated( At Electrical room and LMR)
381Providing and laying of 600mm (L) x 600mm (W) x 600mm (D)Inspection Chamberwith pre cast Cover and all necessary accessories as required
382Providing and laying of RCC Hume pipe(NP2) for Communication cables. Cost to include RCC collar and necessary civil works like jointing of hume pipes with mortar as required.(Excavation & Back filling cost not included) - For Communication & Earthing-200 mm Dia RCC Hume pipe
383SINAGE
384Providing and fixingof signage made out of stainless steel (SS304 grade) letters of size 300X300 of depth 50 (N.S.W.I)
385Digital display board (Logo) of round size-4\"-0\" dia.
386PA SYSTEM
38730W HORN ABS ELLIPTICAL-Maximum power 45 W,Rated power (PHC) 30 W,Power tapping 30 / 15 / 7.5 / 3.75 W,Sound pressure levelat rated power / 1 W(1 kHz, 1 m)-115 / 100 dB (SPL),Sound pressure levelat rated power / 1 W(1 kHz, 4 m)-100 / 86 dB (SPL),Effective frequency range(- 10 dB)-212 Hz to 20 kHz, ABS material, two-way system for high-quality speech and music,reproduction, water and dust protected IP66, EN54-24 certified, light gray RAL 7035
38815 Watt Cabinet Speaker ,Description Premium-sound Cabinet Loudspeaker,Maximum power 22.5 W,Rated power (PHC) 15 W,Power tapping 15/7.5/3.75/1.9 W,Sound pressure level at rated power / 1 W (1 kHz, 1 m)-99/87 dB (SPL),Effective frequency range (-10 dB) 95 Hz to 20 kHz,Opening angle at 1 kHz / 4 kHz(-6 dB)-184° / 112° (hor.), 170° / 35°(ver.),Rated input voltage 11/70/100 V,Rated impedance 8/326/667 ohm
38960 Watt 4 microphone / line inputs, plus music source input,Announcement only output, 3-wire volume override,, 2-tone chime Frequency response (line) - 80Hz to 18kHz (+1/-3dB @ -10 dB ref. rated output), Distortion - <1% at rated output power, 1kHz, Loudspeaker direct out put - 100V, 4Ohm, Input Voltage - 230VAC +10% at 50/60Hz or 24VDC
390480W BOOSTER AMPLIFIER FOR POWER EXPANSION Frequency response - 60Hz to 18kHz(+1/-3dB at -10 dB ref. rated output, Distortion - <1% at rated output power, 1kHz, S?N (flat at max Volume) - >90dB, Loudspeaker direct output - 100V, 70V, 8/4 Ohm, Input Voltage - 230VAC +10% at 50/60Hz or 24VDC
391Microphone features a large press to talk call button for uease of use and the flexible gooseneck enables the microphone to be positioned as required. A green LED confidence light illuminates to let you know the mic is in use,PTT-key for calls for activation,Momentary or toggle,Green LED, indicating microphone active,Stable metal base design with fixed 2 m cable and lockable Euro style connector,Phantom powered by amplifier
3929U Mounting Rack
3932Core 1.0sqmm Loudspeaker Cable
394Cabling of the Loudspeaker Cables as per site condition
395Installation of speaker, amplifier, testing and commissioning of the system
396FIRE FIGHTING
397FIRE EXTINGUISHERS-(make-Fire Tipsintime/Fire Shield)Providing and Fixing carbon dioxide type Fire Extinguisher -a) 4.5 kg. capacity
398Providing and fixing ABC fire extinguisher fixed with bolts, nuts and washers complete in all respects.a) 6 kg. capacity
399EXIT SIGNAGE With Evacution System-SITC of Self illuminated Autoglo exit Signs- Fire Exit with one side arrow size.300x150mm.

AI Tender Summary

OUR REF NO 31677239
AUTHORITY Government Departments
TENDER VALUE 1 Crore
LAST DATE 11-04-2022
Authority
Authority Name Orissa State Road Transport Corporation
Work Description Construction Of Bus Stand At Junagarh, Dist-Kalahandi.
Basic Detail
Tender No 111/GM/28/OSRTC/2021-22
Bidding Type Tender
Location
City junagarh
State Odisha
Key Dates
Publish Date 31 Mar 2022
Submission Date 11 Apr 2022
Open Date 12 Apr 2022
Finance
Tender Value 1 Crore
Tender Fee 11800
EMD 1 Lakhs
Exemption Not Available
Document List
3aa06f9c-0c3e-4a6b-a92a-cee10f89270c.html
BOQ_395076.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 31, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 11, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 12, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3aa06f9c-0c3e-4a6b-a92a-cee10f89270c.html

xls

BOQ_395076.xls

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender