| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | STEEL WORK : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 4 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 5 | CEMENT CONCRETE WORK : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 11 | SHUTTERING & FORMWORK :Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 12 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 13 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | Suspended floors, roofs, landings, balconies and accessplatform |
| 15 | Stairs, (excluding landings) except spiral-staircases |
| 16 | PRE CONSTRUCTION ANTI - TERMITE TREATMENT :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 17 | BRICK WORK :Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 19 | WOOD WORK :Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood - 35 mm thick shutters |
| 21 | PVC DOOR FRAME :Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer\"s specification and direction of engineerin-charge. |
| 22 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos ofplastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 23 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 24 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 25 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) |
| 26 | TILES WORKS : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1000x1000 mm |
| 28 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 29 | PLASTERING WORKS : 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 30 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 31 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 32 | GRILL WORKS :Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 33 | PLINTH PROTECTION :Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth. |
| 34 | PAINTING :With ready mixed pink or Grey primer of approved brandand manufacture on wood work (hard and soft wood |
| 35 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 36 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 37 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 38 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 39 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 40 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 41 | DOOR WINDOW FITTINGS : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300mm x 16mm |
| 42 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300mm x 10mm |
| 43 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm |
| 44 | Providing and fixing PTMT Butt hinges with necessary screws etc. complete.75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rodweighing not less than 34 gms |
| 45 | Construction of Officeof Forest Guest House (1st. Floor).STEEL WORK : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 47 | CEMENT CONCRETE WORK : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 48 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 49 | SHUTTERING & FORMWORK : Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers andcantilevers |
| 50 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 51 | Suspended floors, roofs, landings, balconies and accessplatform |
| 52 | Stairs, (excluding landings) except spiral-staircases |
| 53 | BRICK WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 54 | WOOD WORK : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 55 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood35 mm thick shutters |
| 56 | PVC DOOR FRAME :Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing theframe with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer\"s specification and direction of engineerin-charge. |
| 57 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 58 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion less than 12.50 kg/sqm) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 59 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 60 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) |
| 61 | TILES WORKS : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1000x1000 mm |
| 62 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 63 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 64 | PLASTERING WORKS :12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 65 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 66 | 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 67 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including preparation of surface, excluding grading, compete. |
| 68 | GRILL WORKS :Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding. |
| 69 | PAINTING : With ready mixed pink or Grey primer of approved brandand manufacture on wood work (hard and soft wood) |
| 70 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 71 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 72 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 73 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 74 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 75 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 76 | DOOR WINDOW FITTINGS : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300mm x 16mm |
| 77 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300mm x 10mm |
| 78 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm |
| 79 | Providing and fixing PTMT Butt hinges with necessary screws etc. complete.75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rodweighing not less than 34 gms |
| 80 | Boundary Wall Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 81 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 82 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 83 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 84 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 85 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 86 | Lintels, beams, plinth beams, girders, bressumers and |
| 87 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 88 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 89 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)20 mm cement plaster of mix : |
| 90 | 1:4 (1 cement: 4 fine sand) |
| 91 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia 4 mm |
| 92 | Septic Tank Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 93 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 94 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 95 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 96 | Foundations, footings, bases of columns, etc. for mass concrete - Suspended floors, roofs, landings, balconies and access platform |
| 97 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 98 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 99 | 15 mm cement plaster on the rough side of single or half brick wall of mix :(1 cement: 4 fine sand) |
| 100 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick |
| 101 | Sanitary Installation & Water Supply worksProviding and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar tapswith elbow including operated levers |
| 102 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar tapswith elbow including operated levers |
| 103 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 225 mm |
| 104 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe40 mm dia |
| 105 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 106 | Providing and fixing toilet paper holder :Vitreous china |
| 107 | Providing and fixing soil, waste and vent pipes : 100 mm diaSand cast iron S&S pipe as per IS: 1729 |
| 108 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outletSand cast iron S&S as per IS: 3989 |
| 109 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :100 mm dia |
| 110 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 111 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour |
| 112 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gmsProviding and fixing brass bib cock of approved quality : 20 mm nominal bor |
| 113 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bor |
| 114 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm dia nominal outer dia pipes |
| 115 | 20 mm dia nominal outer dia pipes |
| 116 | 25 mm dia nominal outer dia pipes |
| 117 | 32 mm dia nominal outer dia pipes |
| 118 | 40 mm dia nominal outer dia pipes |
| 119 | 50 mm dia nominal outer dia pipes |
| 120 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etcInternal work - Exposed on wall15 mm dia nominal bore |
| 121 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.Internal work - Exposed on wall 20 mm dia nominal bore |
| 122 | 32 mm dia nominal bore metre |
| 123 | 40 mm dia nominal bore |
| 124 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :20 to 40 mm nominal bore |
| 125 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)20 mm nominal bore |
| 126 | 32 mm nominal bore |
| 127 | 40 mm nominal bore |
| 128 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :15 mm nominal bore |
| 129 | 20 mm nominal bore |
| 130 | 25 mm nominal bore |
| 131 | Providing and fixing gun metal non- return valve of approved quality (screwed end) :40 mm nominal bore Horizontal |
| 132 | Vertical |
| 133 | Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length15 mm nominal bore |
| 134 | 20 mm nominal bore |
| 135 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 136 | Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :Up to 6 metres depth |
| 137 | Beyond 6 m and up to 12 m depth |
| 138 | Beyond 12 m and up to 18 m depth |
| 139 | Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality. |
| 140 | Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories. |
| 141 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :50 mm nominal bore |
| 142 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:150 x 100 mm size P typeWith common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 143 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 144 | Reducing Socket, bend, tee, etc. |
| 145 | Filling available excavated earth(excluding rock) in trenches, plinth, sides of foundations etc. in layers not excluding 20 cm in depth, consolidating each deposited layer by ramming and watering upto 50 m and lift upto 1.5 m |
| 146 | Wiring for light point /fan point! exhaust fan point / call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single corecable in surface/ recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm. Copper conductor single core cable etc. as required. Group A |
| 147 | Group B |
| 148 | Group C |
| 149 | Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 x 2.5. sq. mm + 1 x 2.5 sq. mm earth wire |
| 150 | 2x 4 sq. mm+ 1 x 4 sq. mm earth wire |
| 151 | 2 x 6 sq. mm + 1 x 6sq. mm earth wire |
| 152 | 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
| 153 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of plenolic laminated sheet cover in including painting etc. as required.150mmx 75 mm x 60 mm deep |
| 154 | 200 mm x 125mm x 60 mmdeep |
| 155 | 200 mmx 150mm x 60 mm deep |
| 156 | 200 mm x 150 mm x 75 mm deep |
| 157 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 A switch |
| 158 | 15/16A switch |
| 159 | 3 pin 5/6 socket outlet |
| 160 | 6 pin 15/16A socket outlet |
| 161 | Bell push |
| 162 | Supplying and fixing following sizes of mediumclass PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 163 | 25 mm |
| 164 | 32 mm |
| 165 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 166 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 167 | 3 Module |
| 168 | 12 Module |
| 169 | Supplying and fixing metal box of 150mmx 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front Each including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 170 | Supplying and fixing matal box of 180mmx 100mmx 60 mm deep (nominal size) on surface or in-recess with·suitable size of phenolic lall1in!ltedsheet cover in frontincluding providing and fixing 6 pin 5/6& 15/16A socket outlet and 15116A piano type switch, connections, painting etc. as required. |
| 171 | Supplying and fixing brass batten / angle holder including connection etc. as required |
| 172 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 ern) with 1.5sq. mm FRLS PVC insulated, copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the fan etc. as required. |
| 173 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with lSI market HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N |
| 174 | 63 A TP&N |
| 175 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 A, 25 KA, TPMCCB |
| 176 | Supplying and fixing following way,single pole and neutral, shee steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)8 way Double door |
| 177 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPNMCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 178 | Supplying and fixing 5 A to 32 A rating, 240/415 V, I0 KA,_\"C\" curve, miniature-circuitbreaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 179 | Double pole |
| 180 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissionif!getc. as required.40 A |
| 181 | 63 A |
| 182 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB 18 DB complete with connections, testing and commissioning etc. as required.63 A |
| 183 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (ReeB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 184 | 63 A |
| 185 | Supplying and fixing 20A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP,MeB, in sheet steel enclosure,on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. |
| 186 | Earthing with G.I. earth pipe 4.5 metre long, 40 mmdia including accessories, and providing masonry enclosure with cover platehaving locking arrangement and watering pipeetc. with charcoal/coke and salt as required. |
| 187 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering Set pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 188 | Supplying-ana laying 25 mmx 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with G.I.nut, bolt, spring,washer etc. as required. (Jointing shall Dedone by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
| 189 | Providing and laying earth connection from earth electrode with 4.00 mmdia copper wire in 15mmdia G.l. pipe from earthelectrode including connection with copper thimble excavation and re-filling as required. |
| 190 | Providing and fixing of lightning conductor finial, made of 25 mmdia 300 mm long, G.I. tube, having single prong at top, with85mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 191 | Providing and fixing G.l. tape 20 mm x 3 mmthick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 192 | Fixing of copper/ G.I. tape 20 mmx 3 mmthick on parapet or surface of wall for lightning conductor complete as required. (For Horizontal run) |
| 193 | Laying of one number PVC insulated and PVC sheathed / XL power cable of 1.1 KV grade of following size direct in grol including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq.mm |
| 194 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, phosphatised powder painted cubical outdoor type floor mounting compartmentalize panel board of size 0.80M (B) X 0.90M (H) X 0.40M (D) made of 16 SWG(1.66 mm) thick C.R. sheet and 35 mmx 35 x 5 mm size angle-having4 nos. Legs at the bottom.The panel board is to be erected in 1:3:6PCC foundation including brick soling/grouting etc. complete neatly wiring done with provision for one No. 250A 4 Pole MCCBas incomer and outgoing as specified Each and directed by the deptt. Confirmingto IP 43 protection comprising of the following electrical items:1.30mmx 5 mrn 4 strip copper Bus-Bar 0.5 Length each.2.Poilt Lamp with integral ckt LED I 10-230V (Red, Yellow & Blue) = 3 Nos.(Incoming& Outgoing Swuitch Gear of reqd. Rating will be measured and paid separately). |
| 195 | Supplying with including fitting fixing of ceiling fan etc. as directed by theDeptt. |
| 196 | Supplying with including fitting fixing of LED Tube light etc. as directed by the Deptt. |
| 197 | Supplying with including fittingfixing of LED Bulb 12 Watt. etc. as directed by the Deptt.LED/Home lighting solution |
| 198 | Supplying with including fitting fixing of Exhaust Fan etc. As directed by theDeptt. |
| 199 | Supplying and fixing of 3 H.P. 3 Phase 100well A-Class insulation withmstar delta starter control & switch gearTexmo/Crompton Greaves/CIR/V-Guard equivalent make) fully automatic citation with all accessories complete. |
| 200 | Supplying including testing and commissioning of Air cooled D.O. set coupled complied with current CPCB - II emission norms suitable attenuator of220/4I5V, AC, 1/3Ph. 08 Pf. mounted on (I) M.S. fabricated KOEL Green by air/Skan ) D.G. (15 KVA 1ph Air cooled with rtd Panel silent Fiesel generator set). |
| 201 | Supplying of following size PVCIXLPE insulated and PVC sheathed 1.1 KV grade. Solid Aluminium conductor up to 10 Sq. mm , Balance standed conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq.mm, balance Aluminium strip, 36 Galvanised-wire-for-cablesup to 2 x 10 sq.mm 4 x 6 sq. mm & balance all Galvanised steel strip) extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (part-I) 1988 armoured U.G. cable as specified and Directed by the deptt. (HavellslRR Kabel or equivalent make as approved by this Deptt.35 sq.mm4 Core Armoured U.G. Cable Mescab make.) |
| 202 | Supplying with fitting & fixing of 12 watt. With hybrid switch Solar All in one street Light with built in mono Crystalline Panel, Lithium iron Battery (LiFeP04) MPPT Charge controller and PIR Sensor with Colour temp. 6000-6500K. Including Connection etc. as required and as directed by the deptt. Complete. |
| 203 | Supplying fitting fixing of electric storage water heater (Geyser) of AOS Jaquar make including necessary connection etc. as required complete and directed by the Department |
| 204 | CI Earth pipe 1.8m Inner 100mm,outer dia 110 mmwith perforated holes of 15mmdia at 30 CM interval along length of the pipe |
| 205 | Phase 4 wire Net Whole Current Tri- vector meter, 3x240V, 10-60A |
| 206 | 3 Ph 4 wire ICS, DLMS, 3X240V, 40- 200A, Class1.0.Thread throught energy metarfor distribution transformer metering (Category. A&C) |
| 207 | 11 KV 400A, GOAB Switch Cum Hom type Fuse Set |
| 208 | LT HRC Fuse for MCCB 400A along with housing unit |
| 209 | 11/0.4KV 25KVA DTR Aluminium Wound BIS Level-2 |
| 210 | 11KV 1C X 50 Sq MM AAAC Covered 45 Conductor |
| 211 | Disc Insulator (Porcelam)70KN (B&S Type) |
| 212 | Pin Insulator (Polymer) 5 KN (F &P 24 mm) |
| 213 | GI Channel Cross Arm (100x50x62200mm) |
| 214 | GI Channel (150 x 75x6)mm |
| 215 | HT Stay Set |
| 216 | 11 KV 10KALightning Arrestor (Station Type, Class 2) |
| 217 | PSC Pole 9.75m |
| 218 | ACSR \"RACCON\" Conductor. |
| 219 | 11 KV DO Fuse Set 200A Assembly |
| 220 | Payment to be paid to the APDCL Authority for Load security. |
| 221 | Work Contigency - 3 % of the Civil works (Approx value Rs. 19123970/-) |