Supply Testing Commissioning And Installation Of Tools Equipments And Machineries At Govt. Industrial Training Institute Salboni- Solar Photovoltaic Power Plant ( 12 Kw ) Pv Module Type- Polycrystalline / Monocrystalline, No. Of Pv Cells Per Module-72 Cells, Total Number Of Pv Modules-28-32 Nos, Max.Power, Pmp@Stc- 300 / 330 / 375Wp, Max.Power Tolerance ( % ) - Complied, Max.Power Voltage ( Vmp ) - 36.5 V, Max.Power Current ( Imp ) @Stc- 8.22 A, Open Circuit Voltage, Voc@Stc- 45 V, Short Circuit Current, Isc@Stc-8.89 A, Nominal Voltage-24V, Nominal Wattage- 300Wp, Temp.Coefficient Of Voc-0.3104, Fill Factor-Complied, Temp.Coefficient Of Voc ( % / C ) -0.3104, Temp.Coefficient Of Pmp ( % / C ) -0.3948, Temperature Co-Efficient Of Isc% / °C ) -0.0687, Normal Operating Cell-46+ / - 2, Temperature ( Noct ) ( °C ) - 46+ / - 2, Operating Temperature ( °C ) -40 To 80, Max Temperature Rise Of Solar Cells Under Severe Working Conditions Over Max. Ambient Temp.-10 To 15Deg, Module Is Suitable To Operate At 500 Ambient Temp-Yes, Cell Efficiency-16%-19%, Module Efficiency-15.46%-15.63%, Temp.Coefficient Of Voc ( % / C ) -0.3104, Maximum System Voltage-36.5V Vmp, No. Of By-Pass Diodes-3 Nos, Mounting Arrangement For Solar Module, Clamp Type, Solar Module Frame-Anodizedaluminium, Material-Tempered & Low Iron Glass, Finish-Ethylene Vinyl Acetate, Types Of Sections Used- Aluminium / Mssections, Module Dimensions ( 1960 X 990 X 42 ) Mm, Pv Panel Weight ( Kg ) -20.5-22.5Kg, Module Life ( Minimum ) -25Years, Pv Array Area ( Sqm ) -64Sqm Approximate, Guaranteed Output Confirm- Yes, Total Plan Foot Area ( Sqm ) - 120Sqm, Control Area ( Sqm ) -120Sqm, String Monitoring Unit-Built In Pcu / Inverter 5 Years Amc Required. 2 Solar Photovoltaic Inverter 3 Kva Hybrid Solar Inverter; 1 Rating 5Kva 2 Nominal Ac Power 5Kw, 3 Nominal Ac Voltage 230V 4 Nominal Ac Current 17-21A, 5 Frequency Range 50Hz ± 0.5% 6 Ac Voltage Range 230 ( -20% +12.5% ) , 7 Power Factor ( + And - ) 0.8-0.9 Lag To Unity 8 Total Harmonic Distortion Less Than 3-5% 9 Protections Ac Over & Under / Voltage Over &Under / Frequency Over Protection / Battery Over & Under Voltage / O / P Overload / O / P Short Circuit / Battery Reverse Polarity / Pv Reverse Polarity / Pv Surge Protection / Pv Over Voltage / Battery Current Limit / Galvanic Isolation / Zero Export & Import 10 Max Pv Input Power 5-5.5Kw, 11 Maximum Dc Voltage 250V 12 Minimum Dc Voltage 150V, 13 Charger Controller Typemppt 14 Mppt Voltage Range 130V-190V, 15 Maximum Dc Current 42-45A 16 Maximum Efficiency 94-96%, 17 Max. Open Circuit320-350 V 18 Wavetrue Sine Wave, 19 Minimum Battery Required 120-150Ah 20 Output Frequency 50 Hz, 21 Voltage Regulation + / - 2.5-5% 22 Frequency Regulation+ / - 0.5 Hz, 23 Power Factor 0.99 24 Overloadupto 120-150 % 30 Sec, 25 Changeover Time < 15-20Msec 26 Phase 1 / 3 Phase, 27 Dc Voltage Ripple <3-5% 28 Ambient Temperature Range -10-0- 56°C 29 Humidity ( Non Condensing ) 0-95%, Non Condensing 30 Degree Of Protection Ip 20-21 31 Standards / Approval Of Pcu Iec 61683, Iec 60068 32 Communication Interface Rs232 / Rs485. Mpipr Ofi Bus / Telephone Modem / Wifi Ethernet Based ( Rj 45 ) / Rs 232 / Rms With Gprs, 33 Enclosure Environment Rating Ip 20-21, 34 Safety And Emc Iec 62116 35 Type Of Batterylead Acid Tubular / Vrla / Lmla 5 Years Amc Required. 3 Battery Battery Type- Lmla / Vrla, Voltage-12 / 24 V, Ah Capacity- 65 / 100 / 150Ah, Container -Battery Rack, Cover- Polypropylene Copolymer ( Ppcp ) , Terminals- M, Electrolyte, Self Discharge-≤5% ( As Per Is13369 ≤10% ) In 28Days, Life Expectancy- 5 Years, Approval-Yes, Service Life-Minimum 5 Years, Ah Efficiency- Above 90%, Charge Efficiency- Above 80%, Maximum Depth Of Discharge ( Dod ) -0.9 5 Years Amc Required. 4 Clampmeter 0 - 100 A ( Digital Type ) . 5 Multimeter Dc 200Mv -1000V, 0 – 10A & Ac 200Mv- 750V , 0-10A, Resistance 0-20 Mω And3 1 / 2 Digit. 6 Earth Tester Analog - 500 V. 7 Spirit Level / Water Level Standardquality 8 Pyranometer Standardquality 5 Years Amc Required 9 Drill Machine Heavy Duty Rotary Type Hammer Drill Machine 10 Spanner D.E. Metric Spanner Double Ended, 6 - 32 Mm. 11 Pliers Combination Plier Insulated, 200 Mm. 12 Screwdriver Set Of 5 13 Torque Wrench ( Standard / Ratchet Type ) , 14 To 68 Nm. 14 Wire Stripper 150 Mm 15 Measuring Tape 5 Meter 16 Line Dori Standardquality 17 Vernier Calliper Vernier Caliper, 150 Mm. 18 Plumb Bob Standardquality 19 Safety Helmet Standardquality 20 Safety Hand-Gloves Standardquality 21 Safety Goggles Standardquality 22 Safety Harness Standardquality 23 Reflective Jacket Standardquality 24 Cnc Simulator 1. Ready For Use Without Setup & Easy To Carry, 2. Milling And Lathe System Switchable On One Simulator, 3. Milling System: Servo 3 Axes, Spindle 1 Axis, 4. Lathes System: Servo 2 Axes, Spindle 1 Axis 5. Manual Guide I Installed For Easy Programming 6. Equipped With E-Stop Switch, Manual Pulse Generator, Feed Override, And Universal Power Unit 7. Possibility To Connect To A Computer Network