Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #31657117

Repair / Replacement Of Street / Security / Perimeter Lights And Allied Works At Technical And Domestic Area Of 19 Wg Af Stn Under Ge ( Af ) Borjhar

Issued by Statutory Bodies & Commissions/Committees · borjhar, Assam
Tender Value
25 Lakhs
Estimated cost
Bid Submission
05 May 2022
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
borjhar → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair / Replacement Of Street / Security / Perimeter Lights And Allied Works At Technical And Domestic Area Of 19 Wg Af Stn Under Ge ( Af ) Borjhar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Apr-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-Apr-2022
2 23-Apr-2022 Date Corrigendum Date 05-May-2022

BOQ

Name of Work: REPAIR/REPLACEMENT OF STREE/SECURITY/PERIMETER LIGHTS LIGHTS AND ALLIED WORKS AT TECHNICAL AND DOMESTIC AREA OF 19 WG AF STN UNDER GE (AF) BORJHAR
Sl. No. Item Description
1Excavating in trenches not exceeding 1.5m wide and not exceeding1.5m in depth/width for laying under ground cable/foundations and getting out in soft/loose soil complete all as specified and as directed. Note: During excavation, no mechanical excavator is permitted to use at site,
2Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
3Removing of surplus excavating material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
4M&L for sand cushioning for protection of LT under ground cable with screen wash sand and punning to proper required cover complete all as specified and as directed.
5M&L brick protection with old size sub class ‘B’brick for PVC under ground cable protection in trench with width equal to length of brick, laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable complete all as specified and as directed.
6Laying only old brick for PVC under ground cable protection in trenches with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable complete all as specified and as directed.Note : Old serviceable retrived during taking out bricks shall re-use.
7M&L excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for making foundation or any other works in hard/dense soil including removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the staring point complete all as specified and as directed.
8M&L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, etc complete all as specified and as directed.
9M&L forPCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in foundation or any other works complete all as specified and as directed. Note: Form work if so required for PCC works are deemed to be inclusive with quoted rate.
10M&L for rendering 10mm thick in CM (1:6) on fair faces of brick works or concrete surfaces complete all as specified and as directed.
11M&L for dismantling of ACSR or AAC conductors of any sizes or types etc. complete, setting aside for taking credit complete all as specified and asdirected.
12M&L for dismantling of cross arms of M.S.channels or angle sections, etc. complete and depositing to MES Store Yard for re-use the serviceable steel sections complete all as specified and as directed.
13M&L for dismantling of insulators of any type and sizes and depositing to MES Store Yard for re-use the serviceable insulators complete all as specified and as directed.
14M&L for dismantling of earth wire or copper conductor, service feeder or distributor span of any type and sizes and depositing to MES Store Yard for re-use the serviceable conductors complete all as specified and as directed.
15M&L for taking out of old bricks of any sizes or types for replacement of old unserviceable cable with new bricks complete all as specified and as directed.
16M&L for taking out of old unserviceable cable of any sizes or types for replacement with new cable complete all as specified and as directed.
17M&L for relaying of heavy duty LT under ground cable of any sizes and types in pipe/trench /cable duct/fixed on wall by proper size shaped GI clamps with nuts, bolts, etc. and making good the disturbed surfaces by cement mortar/paint to match with the existing surface complete all as specified and as directed.
18M&L for connection to Feeder Pillar Box, DB or any other indicatated location by heavy duty round wire armoured LT under ground cable of size 120 Sq.mm, 3.5 Core, 1100 volt grade, HR PVC insulated, HR PVC inner and outer sheathed, multi stranded aluminium cable conforms to IS 7098 (Part-I) 1988 with latest ammendments inpipe/trench/cable duct/fixed on wall by proper size shaped GI clamps with nuts, bolts, etc. and making good the disturbed surfaces by cement mortar/paint to match with the existing surfaces complete all as specified and as directed.
19All as per Serial item No. 18 here-in-before butcable of size 95 Sq.mm, 3.5 Core, 1100 volt grade.
20All as per Serial item No. 18 here-in-before butcable of size 70 Sq.mm, 3.5 Core, 1100 volt grade.
21All as per Serial item No. 18 here-in-before butcable of size 35 Sq.mm, 3.5 Core, 1100 volt grade.
22All as per Serial item No. 18 here-in-before butcable of size 25 Sq.mm, 3.5 Core, 1100 volt grade.
23All as per Serial item No. 18 here-in-before butcable of size 16 Sq.mm, 4 Core, 1100 volt grade.
24All as per Serial item No. 18 here-in-before butcable of size 10 Sq.mm, 4 Core, 1100 volt grade.
25All as per Serial item No. 18 here-in-before butcable of size 10 Sq.mm, 2 Core, 1100 volt grade.
26Supply and use of corrosion inhibiting compound during fixing the cable end in aluminium reducer terminals or any other specified location complete all as specified and as directed.
27M&L for boring of holes under road, pavement, hard standing, etc. by trenchless technology using ultra sounding techinque and necessary machine for insertion of pipes, suitable for 50mm to 80mm dia GI pipes complete all as specified and as directed.
28M&L for 80mm bore GI pipe, light grade, with all fittings, laid in trenches/wall/pole through MS flat iron of size 25x3mm, including nuts, bolts & washers, etc. of proper sizes for cable protection complete all as specified and as directed.
29All as per Serial item No. 28 here-in-before but 50mm bore.
30All as per Serial item No. 28 here-in-before but 40mm bore
31Taking down old unserviceable/corroded LT feeder pillar box/busbar chamber/DBs of any size or type after disconnection of all electrical connections complete for replacement with new one complete all as specified and as directed.
32Supply, install, testing and commissioning of LT AMF panel for 100 KVA DG Set, IP-54 type, outdoor type, made out of 2mm thick CRCA sheet supported and fixed on structural frame, factory made duly fixed on the groundby PCC foundation in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate). The panel box shall have enamelled danger notice plate of 1.6mm thick, duly painted with two coats of synthetic enamel paint over and including one coat of red oxide primer (internally & externally) on the surface. The panel box is cubicle shaped, roof canopy type, with special type of heavy duty stainless steel door hinges and totally enclosed dust proof and vermin prooffront and back opening with locking arrangements including necessary control circuit connection and necessary cable connection by lugs and glands including provision accommodate battery separately complete all as specified and directed with the provision/comprising of the following electrical equipments/items:-Make : Greaves Cotton/KOEL/Siemens/L&T/ Scheider/ Cummins/Kirloskar Green authorised manufacturer and necessary documents must be submitted prior approval of drawings
33Notes : (i) Contractor shall be checked DG Set before submission of bid, any other spares for both engine and alternator required for functioning of DG AMF panel are deemed to be include in the quoted rate.(ii) Any other accessories such as connectors, printed ferrules, slives, gromet, neoprene gaskets, PVC chanel, DIN rail, etc. which are not mentioned are to be demmed included in quoted rate.(iii) Contractor shall submit drawing of AMF panel, power/control circuit diagram in laminated paper in duplicate after necessary of manufactures/authorised manufacturer.AMF panel shall comprises of :-(i) Microprocessor based control and annunciator Unit or Genset Controller Unit for auto orv manual starting of DG Set and to enemerate alarm to protect the generator against out of range voltage, out of range frequency, over load, low oil pressure, high temperature, low battery voltage including necessary control circuit connection/probe connection from DG Set to control panel - 01 No. Make : Koel/Deep Sea
34(ii) Relay Card 6 CH 12 volt DC - 01 Set(iii) ECD Card - 01 No(iv) LED indicating Lamp (as required) Make : L&T/Siemens/Scheider(v) Three position/two position selector switches (as required) Make : L&T/Kaycee/Siemens(vi) Current transformer (200/5, 5VA, Cl-1) Make : AE/L&T/BHEL/Oblum(vii) Surge Protection Device - 01 No. Make : L&T/BHEL/Oblum/BCH(viii) LED Ammeter (3 phase, 0 -200 Amp) -01 No Make : L&T/Siemens/Scheneider(ix) Hooter - 01 No (x)Battery Chargers Unit - 01 No (xi) Remote Monitoring Unit - 01 No(xii) Fuses with Fuse base (As required)(xiii) Control/Power Cables - FRLS Type, Copper, 1100 volt (As required, sizes as per requirement but not less than 2.5 sqmm)
35(xiv) MCB SP (DC) (As required) Make : L&T/ Havells/Legrand/Indo Asian (xv) MCCB 160 Amps 415 volts (Vertically Placed), 4 pole - 02 NosMake: Legrand/Havells/L&T/Scheider (xvi) Power Contactor 3 phase 160 A, 415 V, 4P - 02 NosMake: ABB/Schneider/L&T/Legrand/Indo AsianNotes : (i) Contractors shall check the DG Set before submission of bid, any other spares for both engine and alternator side required for functioning of DG AMF panel are deemed to be included in the quoted rate. (ii) Any other accessories such as connectors, printed ferrules, slives, gromet, neoprene gasket, PVC channel, DIN rail etc which are not mentioned above are deemed to be included in this rate. (iii) Manufacturer should submit drawing of panel, power/ control circuit diagram in laminated paper in duplicate after necessary approval of the same from competent authority before procurement action from manufacturer.
36Supply, installation, testing, commissioning of LT feeder pillar box, IP-54 typeof suitable sizes (leg of the feeder pillar should not be less than 600mm length) out door type made out of 3.15mm thick CRCA sheet supported and fixed on structural frame, factory made duly fixed on the ground byfoundation of PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) of size 700mm x 300mm x 600mm on the adjacent pairs of leg and rendering the same. The feeder pillar box shall consists of enamelled danger notice plate of 1.6mm thick, duly painted with two coats of synthetic enamel paint over and including one coat of red oxide primer (internally & externally) on the surface. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty stainless steel door hingesand totally enclosed dust proof and vermin prooffront and back opening with locking arrangements and arrangement of fixing padlock on the front door with one no 7 levers Pad Lock (Type Nav-Tal, 6 levers, 3 Keys of make Make- Godrej) complete all as specified and as directed with provision/accommodation of the following electrical items :-
37Make/manufactured from CPRI type tested manufacturer i.e L&T/ Indo Asian/Unitec/Milestone/ C&S Electric Ltd/ Advance/Scheideror (A) INDICATING DEVICES : Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 04 No (B) INCOMING/ OUT GOING :(i) Aluminium bus bar 4 strips (covered with PVC insulated sleeves) 600 Amps capacity, including connection etc complete – 01 Set(ii) MCCB 250 Amps 415 Volts, Adjustable Thermal Magnetic Trip Unit, Ics = 100%Icu,4 pole, 25 kA breaking capacity with spreader sets = 01 Nos.Make : ABB/ Schneider/ Legrand/L&T (Incoming to FP Box from one source)(iii) MCCB 250 Amps 415 Volts, Adjustable Thermal Magnetic Trip Unit, Ics=100%Icu,4 pole, 25KA breaking capacity with spreader sets = 01 Nos.Make : ABB/Schneider/Legrand/L&T (Incoming to FP from another sources)Note- The connection between the MCCB and bus bar should be done by aluminium bar or cable of suitable rating with nut, bolts & washer.
38(C)OUT GOING :(i) Open execution type onload changeover switch 250 Amps, 415 Volts, 50 Hz = 02 NosMake : ABB/ Legrand/ Siemens/ L&T(ii) MCCB 100 Amps 415 Volts, Adjustable Thermal Magnetic Trip Unit, Ics = 100%Icu,4 pole, 25 kA breaking capacity with spreader sets = 04 Nos. Make : ABB/Schneider/Legrand/L&T (Incoming to FP Box from one source) Notes : (i) All cables in the feeder pillar box should be properly glanded and thimbled. (ii) Cost of cable Lugs or thimbles for connections of UG cable are deemed to be included in this rate.
39M&L for fixing the aluminium terminal in cable end (through corrosion inhibiting compound) of cable size 95 sq.mm complete all as specified and as directed. Note: Corrosion inhibiting compound which shall be used during crimping of terminal shall be measured and paid separately.
40All as per Serial item No. 33 here-in-before cable size 70 sq.mm
41All as per Serial item No. 33 here-in-before but cable size 50 sq.mm
42All as per Serial item No. 33 here-in-before but cable size 35 sq.mm.
43All as per Serial item No. 33 here-in-before but cable size 25 sq.mm.
44All as per Serial item No. 33 here-in-before but cable size 16 sq.mm.
45All as per Serial item No. 33 here-in-before but cable size 10 sq.mm.
46M&L for fixing the cable junction boxes of size 225 x 295 x 122mm with terminals for 35 sq.mm, 3.5 core, 1100 volt cable, IP 66/69, weather proof, outdoor installation type with threaded cable glands and pole mounting brackets, etc. complete all as specified and as directed.
47M&L for fixing the cable junction boxes of size 205 x 255 x 112mm with terminals for 10 - 25 sq.mm, 4.0/3.5 core, 1100 volt cable, IP 66/69, weather proof, outdoor installation type with threaded cable glands and pole mounting brackets, etc complete all as specified and as directed.
48M&L for making two nos hole (one at top portion of the pole and one at bottom portion of the pole) for throughing 1.5 sq.mm, 3 single core, 1100 volt cable with in steel tubular swaged pole of type SP 31/ 55 through drill or other required T&P complete all as specified and as directed.
49M&L for 3 single core PVC insulated multi stranded copper conductorcable 1.5 sq.mm 1100 volt unarmoured for connection from loop /junction box to street lights/security lights,etc. complete all as specified and as directed.
50M&L for triming the tree branches of girth 10 to 20cm, falling/touching the HT/LT overhead line in various area ofAF Station Borjhar with skilled labours and cutting tools and disposed the branches to a distance not exceeding 50m from starting point complete all as specified and as directed.
51All as per Serial item No. 44 here-in-before but girth 20 to 30cm
52M&L for painting of RCC pole, 7.5m approx above ground level with two coats of sky blue anti algal or fungal paint (second coat of paint to be carried out one day later after the first coat), over a coat of primer on plaster/cement surfaces of 2m from the ground level and two coats of white colour anti algal or fungal paint (second coat of paint to be carried out one day later afterthe first coat) over and including one coat primer on plaster/ cement surfaces of any description including preparation of old painted surfaces and steel bracket to be painted with two coats of aluminium paint (second coat of paint to be carried out one day later afterthe first coat), over and incuding one coat of red oxide primer complete all as specified and as directed.
53M&L for painting of steel tubular swaged poles, 7.5m approx above ground level including brackets, clamps, etc. with two coats of sky blue enamel paint (second coat of paint to be carried out one day later after the first coat) over and including one coat of red oxide primer on steel surfaces of 2m from the ground level and two coats of aluminium paint (second coat of paint to be carried out one day later after the first coat) over and including one coat of red oxide primer on steel surfaces of any description including preparation of old painted surfaces complete all as specified and as directed.
54M&L for painting of steel tubular swaged swan neck poles, 7.5m approx above ground level including brackets, clamps, etc. with two coats of sky blue enamel paint (second coat of paint to be carried out one day later after the first coat) over and including one coat of red oxide primer on steel surfaces of 2m from the ground level and two coats of aluminium paint (second coat of paint to be carried out one day later after the first coat) over and including one coat of red oxide primer on steel surfaces of any description including preparation of old painted surfaces complete all as specified and as directed.
55M&L for painting of steel tubular swaged pole, 10.5m approx above ground level including angles, clamps, etc. with two coats of sky blue enamel paint (second coat of paint to be carried out one day later afterthe first coat), over and including one coat of red oxide primer on steel surfaces of 2m from the ground level and two coats of aluminium paint (second coat of paint to be carried out one day later after the first coat) over and including one coat of red oxide primer on steel surfaces of any description including preparation of old painted surfaces complete all as specified and as directed.
56M&L for cable jointing kit for 1.1 KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/XLPE armoured aluminium conductor cable of size 70 - 120 sq.mm complete all as specified and as directed.
57All as per Serial item No. 51 here-in-before but for cable size 25-50 sq.mm.
58M&L for GI pipes of size 15mm bore, light gradewith all fittings, laid in trenches/wall/pole through and including MS flat iron of size 25 x 3mm, by means of nuts, bolts and washers (as required) of proper sizes for protection of cables complete all as specified and as directed.
59M&L for hot dip galvanised (as perBS EN ISO 1461 1991) brackets of 40mm dia, medium grade, 1.5m long for fixing LED type street light luminaires, fixing it to pole through MS clamps, nuts, bolts, washers, etc. including taking down old unserviceable one complete all as specified and as directed. Notes: Any welding works related to bracket should be carried out at the factory premises of the manufacturers
60M&L for taking down & refixingLED street/ flood light luminaries after replacement of unserviceable LED outdoor driver with new one of any type or capacity or any other specified works complete all as specified and as directed. Note:- Driver will be measured and paid separately in relevant items
61Supply only LED outdoor drivers for 120 W, 230 volt LED outdoor street light luminaires complete all as specified and as directed.Note: Manufacturer of unserviceable LED luminaires are Surya Roshni Ltd, Bajaj and Havells
62Supply only LED outdoor drivers for 90 W, 230 volt LED outdoor street light luminaires complete all as specified and as directed.Note: Manufacturer of unserviceable LED luminaires are Surya Roshni Ltd, Bajaj and Havells
63Supply only LED outdoor drivers for 60 W, 230 volt LED outdoor street light luminaires complete all as specified and as directed.Note: Manufacturer of unserviceable LED luminaires are Surya Roshni Ltd, Bajaj and Havells
64Supply only LED outdoor drivers for 160 W, 230 volt LED outdoor floodlight luminaires complete all as specified and as directed.Note: Manufacturer of unserviceable LED luminaires are Surya Roshni Ltd, Bajaj and Havells
65Supply only LED outdoor drivers for 120 W, 230 volt LED outdoor floodlight luminaires complete all as specified and as directed.Note: Manufacturer of unserviceable LED luminaires are Surya Roshni Ltd, Bajaj and Havells
66Excavating in trenches not exceeding 1.5m wide and not exceeding1.5m in depth/width for planting of steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & screws including getting out in hard dense/rock complete all as specified and as directed.
67Add for each additional 1.5m or part thereof in depth beyond the first 1.5m and getting out in hard dense or rock complete all as specified and as directed.
68M&L for disconnection of electric supply anddemolition of existing PCC foundation of poles, taking down old steel tubular swaged pole or RCC pole of 9m long and re-installation and commisioning of the pole within 2.0 Km radius of existing location complete all as specified and as directed. Note: PCC works for foundation will be measured and paid separately.
69M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) for planting of poles, foundations, etc. including necessary formwork complete all as specified and as directed.
70M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for planting of poles,foundations, etc. including necessary formwork including rendering 10mm thick in cement mortar (1:6) on fair faces of concrete surfaces above ground level complete all as specified and as directed.
71S&F power contactor 200 amp, 415 volt, 4P on the existing panel complete all as specified and as directed. Make : ABB/Schneider/L&T/Legrand/Indo Asian
72S&F LED street light luminaries with aesthetically designed IP-66, pressure die cast aluminium housing and toughned flat glass with wattage 90 W ± 5%, 230V, 50 Hz, current < 0.414, power factor > 0.95, Ithd <10%, system efficacy 100 lumen/W, with lumen maintenance 50000 Hrs @ L70 for LED, LED should be LM 80 certified, peanut lens for batwing 135/ 85° light distribution with surge protection kV including taking out old unserviceable one complete all as specified and as directed. Make : Philips, Type BRP 410 LED CW 066 NR PC S1 PSU GR XT / Orient, Type LSFS-090-C / Havells, ENDURAPEARL PLUS SL90W LED 757PASYTOPCASTHO

AI Tender Summary

OUR REF NO 31657117
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 05-05-2022
Authority
Authority Name Military Engineer Services
Work Description Repair / Replacement Of Street / Security / Perimeter Lights And Allied Works At Technical And Domestic Area Of 19 Wg Af Stn Under Ge ( Af ) Borjhar
Basic Detail
Tender No 8281/BOR/E8
Bidding Type Tender
Location
City borjhar
State Assam
Key Dates
Publish Date 23 Apr 2022
Submission Date 05 May 2022
Open Date 07 May 2022
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
Tendernotice_1.pdf
30e148f9-4a12-4ef4-854d-12aa87d172cb.html
8281Tender.pdf
BOQ_576511.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 23, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 25, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 05, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 05, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 07, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

30e148f9-4a12-4ef4-854d-12aa87d172cb.html

pdf

8281Tender.pdf

xls

BOQ_576511.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders