Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-04-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-04-2022 |
| 2 | 13-04-2022 | AMENDMENT TO NIT COST AND MISC AMD | Other | 18-04-2022 |
| Sl. No. | Item Description |
| 1 | Taking down carefully existing storage type geyser 25/50 ltr capacity and disconnection of inlet and outlet water connection taking out all accessories inside the body removing nut bolt from base plate assembly cleaning of inside of stainless steel/copper tank with the help of brush, checking any leakage testing of each unserviceable parts/spairs for its functioning and replacement of unserviceable parts, re fixing the same after cleaning and making proper functioning to maintain proper water temperature, complete all as specified and directed by Engineer-in-Charge.Note: (i) The accessories/spare parts which are required to be replaced shall be measured and paid for separately as \"Supply only\" under respective items of BOQ. |
| 2 | Taking out leakage storage type water heater 25/50 ltr cap dismantling and taking out the inner tank, find out the leakage point brazing the leakage point and replacement of glass wool insulations using glass wool and refixing the same after testing all as directed by Engr-in-Charge. |
| 3 | Supply only heating element of capacity 2 KW including rubber washer, bolts, clamps etc for geysers of 50 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge.Make : Dasspass/Theta/Elcon |
| 4 | Supply only heating element of capacity 1.5 KW including rubber washer, bolts, clamps etc for geysers of 25 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge.Make : Dasspass/Theta/Elcon |
| 5 | Supply only non return valve brass chromium plated 15mm bore horizontal/vertical type suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge.Note : The quoted rate shall deemed to include opening of existing GI fitting and cutting & threading of existing pipe line, if required for fixing new NRV. |
| 6 | Supply only pressure release valve (spring controlled) brass chromium plated for geysers of 25/50 ltr capacity of any make and type complete all as specified and as directed by Engineer-in-charge. |
| 7 | Supply only Hot water outlet brass chromium plated connection 12mm bore 45cm long with chromium plated adopter and washer at both ends of required size complete all as specified and as directed by Engineer-in-charge. |
| 8 | Supply only heavy duty inlet PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified and as directed by Engineer-in-charge.Make : Prayag, Polytuf, Jindal |
| 9 | Supply only base plate assembly consisting of inlet and outlet CP brass pipe, thermostatic, CP brass pipe, drain plug, pressure release valve spring controlled and rubber gasket, bolts, washers etc as per existing pattern suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge. |
| 10 | Supply only indicator lamp round/rectangular type as per existing suitable for 25/50 ltr capacity geysers working on 230 volt AC supply complete all as specified and as directed by Engineer-in-charge.Make:- Siemens / L&T / C & S / AE |
| 11 | Supply only thermostatic cutout (ISI marked) suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge.Make : Dasspass/Theta/Elcon |
| 12 | Supply only thermostatic switch (ISI marked) of range 0°C to 80°C suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge.Make : Dasspass/Theta/Elcon |
| 13 | Supply only outer shell duly spray painted as per existing size and shape made of 20 gauge MS sheet suitable for 25/50 ltr capacity geyser of any make including rubber ring and screws complete all as specified and as directed by Engineer-in-charge. |
| 14 | M&L for preparing surfaces of geyser of capacity of 25/50 Ltrs, making dust free, scratching rust and old paint wherever required with sand paper and wire brush and spray painting with one coat of red oxide & one coat of synthetic enamelled paint of approved shade to ) complete all as specified and directed by Engr-in-charge.Make of Paint :- ASIAN / NEROLAC / SHALIMAR / BERGER |
| 15 | Supply only copper tank of 25/50 ltr capacity geysers as per existing size and shape complete all as specified and as directed by Engineer-in-charge.Make :- Jindal / Bir / Leader |
| 16 | Supply only fusible safety brass plug as per existing suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge. |
| 17 | S&F in repair 15mm bore stop valve fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge.Make : Zoloto / Prayag / SEIKO / NETA/ GEM |
| 18 | WINDOW TYPE AC OF CAPACITY 1.5 TR OF MAKE CARRIER / VIDEOCON / VOLTAS /LGM&L for periodical services of Window type AC complete with dismantling internal and external units into components, cleaning of components fanc motor, housing, filters etc. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain/condensate pipe, connecting up and testing to make the unit fully working condition complete all as specified and directed by Engineer-in-ChargeNote: Equipment shall be serviced once in six months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 19 | Dismantling/taking out defective compressor unit from window type AC and S&F same model new one company sealed compressor reciporcating type of 1.5 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete with connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including soldering of copper pipes, replacement of capillary tube and dryer filter, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge Make :- KIRLOSKAR /CARRIER/TECUMESHNote :- This item shall not include the capillary tube, cost of gas and gas charging which shall be measured and paid for separately under respective items of BOQ. |
| 20 | S&F in replacement of air filter made out of Jute/PVC complete all as specified and directed by Engr-in-charge |
| 21 | S&F in replacement of overload protector including terminal cover and clips suitable for 1.5 TR capacity AC complete all as specified and directed by Engr-in-charge Make :- INDFOS/SHRIRAM/ RANUTRAL. |
| 22 | S&F in replacement of starting relay assembly including clips and terminal cover suitable for 1.5 TR capacity AC complete all as specified and directed by Engr-in-chargeMake :- INDFOS/SHRIRAM/RANUTRAL. |
| 23 | S&F in replacement of starting capacitor 100/120 MFD including thimble for connection complete all as specified and directed by Engr-in-charge Make : HAVELLS / HPL /DUCATI / EPCOS/ NEPTUNE |
| 24 | S&F in replacement of running capacitor 36/45 MFD including thimble for connection complete all as specified and directed by Engr-in-charge.Make : HAVELLS / HPL /DUCATI / EPCOS/ NEPTUNE |
| 25 | S&F in replacement of thermostat switch including knob plate and screws etc complete all as specified and directed by Engr-in-charge MAKE-RANUTRAL/INDOFOSS/HONEYWELL. |
| 26 | S&F in replacement of motorDouble shaft 1HP to 1.5HP Single phase, 3 speed, 230 volts including necessary fittings, capacitor, testing and commissioning complete all as specified and directed by Engr-in-charge.Make :- CROMPTON / AUE |
| 27 | S&F in replacement of wiring kit comprising of copper conductor cables for connections of assembly complete all as specified and directed by Engr-in-charge |
| 28 | S&F in replacement of selector switch 20 Ampswith screws and knobs complete all as specified and directed by Engr-in-chargeMAKE - ANCHOR/AGI / BENTEX |
| 29 | S&F in replacement of cooling coil comprising of copper pipes of heavy grade of adequate size including necessary mild steel CP screws, brazing and connecting with existing system complete all as specified and directed by Engr-in-charge |
| 30 | S&F in replacement of condenser as per sample made out of copper tubes of heavy grade of adequate size including material and labour for replacement of mild steel CP screws, nuts/bolts, brazing and connecting with existing system complete all as specified and directed by Engr-in-charge |
| 31 | S&F in replacement of air flow control front grill made out of PVC heavy duty including fixing screws for AC complete all as specified and directed by Engr-in-charge. Make :- CARRIER/VOLTAS/ NEPOLIAN / VIDEOCON |
| 32 | S&F in replacement of air flow and exhaust blower including tightening screws made out of PVC aluminum complete all as specified and directed by Engr-in-charge |
| 33 | S&F in repair base frame with body coverhaving all fitting / fixtures to accommodate all accessories made out of 1.25 mm thick mild steel plain sheet duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-chargeMake of AC :- CARRIER / VOLTAS / VIDEOCON / WHIRLPOOLMake of Paint:- NEROLAC / ASIAN / SHALIMAR / BERGER |
| 34 | S&F in replacement of fan motor for window type ACas specified and directed by Engr-in-charge. |
| 35 | S&F in replacement of capillary tube for window type AC including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 36 | WATER COOLER OF 40/80 LITRES, 120 Ltrs & 150 Ltrs CAPACITY OF MAKE VOLTAS / USHA/ BLUE STARM&L for periodical repairs and maintenance of water cooler of cooling capacity upto 40/120 ltrs/hrs and storage capacity upto 80/120 Ltrs complet with disconnecting the water connection, inserting dead plug, dismalting the fan motor, fan blades, condensor etc. Checking up and rectification of wiring and connections, replacement of necessary parts accessories, cleaning of the cold water tank, piping, refrigerant lines, realligment of the fan coil unit and replacement of drain pipe, connecting to water supply lineNote: Equipment shall be serviced once in six months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 37 | Opening up and disconnecting the defective unserviceable sealed compressor unit of water cooler storage type 40 ltr/hrs and supply and fixing new compressor obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge Make :-LG /KIRLOSKAR /WHIRLPOOL Note :- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items. |
| 38 | All as per item no -37 here in before but for water cooler of 120/150 Ltrs cap. |
| 39 | S&F in replacement of relay suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge. Make- RANUTRAL / SHRIRAM / INDFOS / USHA. |
| 40 | S&F in replacement of starting capacitor 40/60/80 MFD complete all as specified and directed by Engr-in-charge.Make : HAVELLS / HPL /DUCATI / EPCOS/ NEPTUNE |
| 41 | S&F in replacement of running capacitor 6 MFD complete all as specified and directed by Engr-in-charge Make : HAVELLS / HPL /DUCATI / EPCOS/ NEPTUNE |
| 42 | Taking down and dismantling blower motor of water cooler and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement ofgun metal bushes, shaft, clamps includingtesting and commissioning complete all as specified and directed by Engr-in-charge. |
| 43 | S&F in replacement of fan blade of blower motor made out of aluminum alloy fixed with mild steel chromium plated screw etc complete all as specified and directed by Engr-in-charge. |
| 44 | S&F in replacement of 15 mm bore push type water tap brass chromium plated complete all as specified and directed by Engr-in-charge. Make :- JONSON / PARKO / KINGSTON / GEM SANITATION APPLIANCES |
| 45 | S&F in replacement of PVC flexiblehose pipe, 32mm dia as in connections fixed at one end of waste water trapwith clamp and other end left free to open at appropriate distance complete all as specified and directed by Engr-in-charge. |
| 46 | S&F in replacement of blower motor of capacity (1/32HP) including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge.Make- CROMPTON/AUE/GE |
| 47 | S&F in replacement of condenser made out of copper tubes of heavy grade of adequate size including necessary screws, brazing to existing gas pipes & testing complete all as specified and directed by Engr-in-charge. Make -CROMPTON/ USHA/ AUE/GE |
| 48 | M&L for preparing surfaces of water cooler, making dust free, scratching rust and old paint wherever required with sand paper and wire brush and spray painting with one coat of red oxide & one coat of synthetic enamelled paint of approved shade to water cooler of capacity 40/80 litre of size150 cm x 65 cm x 50 cm (approximate) complete all as specified and directed by Engr-in-charge.Make of Paint :- ASIAN / NEROLAC / SHALIMAR / BERGER |
| 49 | All as per srl item No 48 here-in-before but to water cooler of capacity 120 ltrs complete all as specified and directed by Engr-in-charge. |
| 50 | S&F in replacement of thermostat switch suitable for water cooler of any capacity including knob, plate and screws complete all as specified and directed by Engr-in-charge.Make- SHRI RAM/ INDFOS/WHIRLPOOL/VOLTAS. |
| 51 | S&F in replacement of capillary tube for water cooler of any capacityincluding brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 52 | S&F in replacement of waste water drain tray for water cooler of any capacityincluding pvc clamp necessary screw and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 53 | REFRIGERATOR OF CAPACITY 165/180/190/310/320 LTR. MAKE :– HAIR / VIDEOCON / KELVINATOR / LGM&L for periodical Services of Refrigerator of any capacities complete with dismantling internal and external units into components, cleaning of components fan motor, blower, housing, filters etc. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, realligment of the fan coil unit and replacement of drain/ condensate pipe, connecting and testing, to make the unit fully working condition complete all as directed by Engineer-in-Charge.Note: Equipment shall be serviced once in six months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 54 | Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 165 ltr/180/190 ltr and supply and fixing new compressor obtained from the factory outlet/ authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge. Make :- KIRLOSKAR /CARRIER /WHIRLPOOL/LG Note:- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items. |
| 55 | Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 310/320 ltr and supply and fixing new compressor obtained from the factory outlet/ authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge. Make :- KIRLOSKAR /CARRIER /WHIRLPOOL/LGNote:- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items . |
| 56 | S&F in replacement of relay assembly suitable for 165/180/190/310/320 litre capacity refrigerator including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.Make- RANUTRAL/INDFOS/WHIRLPOOL/VOLTAS |
| 57 | S&F in replacement of thermostat switch suitable for refrigerator capacity 165/180/190/310/320 litre including knob, plate and screws complete all as specified and directed by Engr-in-charge.Make- SHRI RAM/ INDFOS/WHIRLPOOL/VOLTAS. |
| 58 | S&F in replacement of condenser suitable for 165/180 litre capacity refrigerator made out of mild steel powder coatedtubes of heavy grade of adequate size including necessary mild steel clamps and mild steel CP screws, brazing and connecting to existing gas system complete all as specified and directed by Engr-in-charge. |
| 59 | All as item No 58 here-in-before but of capacity 310/320 litre Refrigerator |
| 60 | S&F in replacement of door gasket magnetic type suitable for refrigerator of capacity 165/180/190/310/320 litreincluding strip cover and mild steel CP screws complete all as specified and directed by Engr-in-charge. |
| 61 | S&F in replacement OLP 43/33 suitable for refrigerator 165/180/190/310/320 ltr complete all as specified and directed by Engr-in-charge. |
| 62 | Supply only in replacement of chiller tray of PVC suitable for refrigerator 165/180/190/310/320 litre capacity as per existing pattern complete all as specified and directed by Engr-in-charge. |
| 63 | Supply only in replacement of PVC vegetable tray suitable for Refrigerator of capacity 165/180/190/310/320 litre as per existingpattern complete all as specified and directed by Engr-in-charge. |
| 64 | S&F in replacement of evaporator / freezer cabinet complete with freezer door made out of aluminum tubes of adequate sizefor refrigerator of capacity 165/180 litre including making connection with old system complete all as specified and directed by Engr-in-charge. |
| 65 | All as per srl item No 64 here-in-before but refrigerator of capacity 310/320 litre. |
| 66 | S&F Screw type bulb AC 230 Volt suitable for refrigerator of capacity 165/180/190/310/320 Lrs complete all as specified and directed by Engr-in-charge. |
| 67 | S&F in replacement of capillary tube for refrigerator of capacity 165/180/190/310/320 Lrsincluding brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 68 | S&F in replacement of door push button for refrigerator of capacity 165/180/190/310/320 Lrs complete all as specified and directed by Engr-in-charge. |
| 69 | S&F in replacement of filter dyer for refrigerator of capacity 165/180/190/310/320 Lrs complete all as specified and directed by Engr-in-charge. |
| 70 | DEEP FREEZER MAKE VOLTAS/BLUE STAR/ARCIM&L for periodical Services of Deep Freezer of any capacities complete with dismantling internal and external units into components, cleaning of components fan motor, blower, housing, filters etc. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, realligment of the fan coil unit and replacement of drain/ condensate pipe, connecting and testing, to make the unit fully working condition complete all as directed by Engineer-in-Charge.Note: Equipment shall be serviced once in six months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 71 | Opening and Disconnecting the defective unserviceable sealed compressor unit of deep freezer of any make and type, AC 230 volts single phase of any capacityand supply and fixing new compressor obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete all as specified and directed by Engr-in-charge.Make : Volts / Kirloskar / TecumeshNote :- This item shall not include cost of gas and gas charging which shall be measured and paid forseparately under respective item. |
| 72 | S&F in replacement of relay assembly suitable for deep freeze including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.MAKE: INDFOS / VOLTAS. |
| 73 | S&F in replacement of thermostat switch suitable for deep freezeincluding knob, plate and screws complete all as specified and directed by Engr-in-charge.MAKE : WHIRLPOOL / VOLTAS / INDFOS. |
| 74 | S&F in replacement of door gasket magnetic type suitable for deep freezeincluding strip cover and mild steel CP screws complete all as specified and directed by Engr-in-charge. |
| 75 | S&F in replacement of OLP suitable for deep freezecomplete all as specified and directed by Engr-in-charge. |
| 76 | S&F as per sample type bulb AC 230 volt suitable for deep freezer all as specified and directed by Engr-in-Charge. |
| 77 | S&F in replacement of blower motor for deep frezeer of existing type and capacity including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge.Make- CROMPTON/AUE/GE |
| 78 | SPLIT TYPE AC CAPACITY 2/1.5 TR MAKE :- CARRIER / VOLTAS / VIDEOCON / LG / HITACHI / DAIKAIN / WHIRLPOOLM&L for periodical services of Split type AC capacity 2/1.5 ton complete with dismantling internal and external units into components, cleaning of components fanc motor, housing, filters etc. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain/condensate pipe, connecting up and testing to make the unit fully working condition complete all as specified and directed by Engineer-in-ChargeNote: Equipment shall be serviced once in six months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 79 | Dismantling/taking out defective compressor unit and supply and fixing new one company sealed compressor rotary type of 1.5 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete including connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge.MakeTECUMSEH / KIRLOSKAR / CARRIER Note :- This item shall not include cost of gas and gas charging which shall be measured and paid forseparately under respective items . |
| 80 | Dismantling/taking out defective compressor unit and supply and fixing new one company sealed compressor reciprocatingtype of 2 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme alongwith test certificate and with one year guarantee card complete including connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge.MakeTECUMSEH / KIRLOSKAR / CARRIER Note :- This item shall not include cost of gas and gas charging which shall be measured and paid forseparately under respective items . |
| 81 | All as per srl item No.80 but of capacity 1.5 Ton Spilt type AC . |
| 82 | S&F in replacement of air filter made out of Jute/PVC suitable for split type AC complete all as specified and directed by Engr-in-charge. |
| 83 | S&F in replacement of running capacitor 36+4,36+6,45+4, 45+6, 55+4, 55+6 MFD complete all as specified and directed by Engr-in-charge.Make : HAVELLS / HPL /DUCATI / EPCOS / NEPTUNE |
| 84 | S&F in replacement of capacitor 4 MFD complete all as specified and directed by Engr-in-charge.Make : HAVELLS / HPL /DUCATI / EPCOS / NEPTUNE |
| 85 | S&F in replacement of starting relay complete all as specified and directed by Engr-in-charge.Make RANUTRAL / INDFOS / SRIRAM |
| 86 | S&F of Printed Circuit Board plate for Split type AC of any make and type, of capacity 2TR/1.5 TRcomplete all as specified and directed. |
| 87 | S&F of swing assembly motor as per existing model/make for split type AC 1.5/2TR unit, including rubber bush complete all as specified and directed. |
| 88 | S&F in replacement of blower motor (Evaporator motor) for Split type AC of any make and type including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge.Make- CROMPTON/AUE/GE |
| 89 | S&F of condenser coil for 2/1.5 TR capacity Spilt type AC including welding/ brazing of pipe line, charging of refrigerantgas and testing of leakage as required including taking out existing one complete all as specified. |
| 90 | S&F in replacement cooling coil for 2/1.5 TR capacity splittype AC including welding/ brazing of pipe line, charging of refrigerantgas and testing of leakage as required including taking out existing one complete all as specified. |
| 91 | S&F in replacement insulation (closed cell elastomeric insulation in tubing) over copper tubing wherever required using approved material as per manufacturers recommendation complete all as specified and directed. |
| 92 | S&F in replacement of thermostat for 2/1.5 TR capacity splittype AC including knob, plate and screws complete all as specified and directed by Engr-in-charge.MAKE : WHIRLPOOL / VOLTAS / INDFOS. |
| 93 | S&F in replacement of Indoor blower motor for Split type AC of any make and type including material and labour for replacement of mild steel clamps, rubber rings complete all as specified and directed by Engr-in-charge. |
| 94 | Supply only in replacement Remote control for Split AC of any make and any capacity or as per sample complete all as specified and directed by Engr-in-charge. |
| 95 | S&F in replacement of capillary tube for Spilttype AC including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 96 | S&F in replacement copper suction pipe line of suitable size (outer dia not less than 1/2\"\" (12.7 mm)) and gauge as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engineer-in-Charge. |
| 97 | S&F in replacement copper discharge pipe line of suitable size (outer dia not less than 1/4\"\" (6.35 mm)) and gauge as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engineer-in-Charge. |
| 98 | S&F in replacement of housing (outer cover) for Split type AC as per sample. |
| 99 | S&F in replacement of Indoor cabinet for split type AC of any make and any capacity or as per sample. |
| 100 | S&F in replacement of Outdoor cabinet for split type AC of any make and any capacity or as per sample. |
| 101 | S&F in replacement of out door unit wall mount stand of Split AC 1.5/2 ton or as per sample for fixing of equipment on wall. |
| 102 | M&L charging of Refrigerents/Top up to Split AC/ Window AC up to maintain reqd temperature as per site condition complete all as specified and directed. |
| 103 | M&L charging of Refrigerentsto Water cooler/ Refrigerator/ Deep freezer up to maintain reqd temperature as per site condition complete all as specified and directed. |
| 104 | Removing the worn out old painted from surface of split unit external, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting all as specified and directed by Engineer-in-Charge. |
| 105 | M&L for cutting and taking out the rusted/damaged portion of the sheet metal of AC/WATER COOLER /DEEP FREEZER /REFRIGERATOR of any capacity and providing new sheet of exiting gauge including welding/brazing as required and painting with two coat of red oxide primer all as specified and directed by Engineer-in-Charge. |
| 106 | Supply in replacement of glass wool for any type of Water cooler /Deep freezer /Refrigerator/ Gyeser with rubber gasket packing with nut bolts etc all as directed byEngineer-in-charge. |
| 107 | Supply and fix in replacement of wall mounting type AC timer havingDelay Time Facility, Auto & manual switch ,Suitable for window ,splits type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals all as specified and directed by Engineer-in-Charge. |
| 108 | S&F in replacment of3 way backlite connector of capacity 20Amps all as specified and directed by Engineer-in-Charge. |
| 109 | S&F in replacement MCB 6-32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :-Legrand/L&T/ Havells / Schneider |
| 110 | S&F in replacement ofsheet metal plug & socket DB, SP, with a two pin and earth plug with socket,230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :-Legrand / Havells / L&T / SchneiderMake of MCB :-Legrand / Havells / L&T / Schneider |
| 111 | S&F in replacement of PVC sheathed cable 3 core copper conductor of size 70/.0076mm, flexible for making connection of window/ Spilt type AC complete all as specified and directed by Engr-in-charge.Make :- Havells / RR Cable/ NICCO / L &T / Finolex |
| 112 | S&F in replacement of PVC sheathed, cable 3 core with copper conductor of size 40/0.0076 flexible complete all as specified and directed by Engr-in-charge.Make- Havells / RR Cable/ NICCO / L &T / Finolex |
| 113 | S&F in replacement of plug top 3 pin 5 Amps heavy duty for refrigerator/water cooler complete all as specified and directed by Engr-in-charge.Make :- LEADER / HAVELLS / LEGRAND |
| 114 | S&F in replacement of plug top 3 pin 15 amps heavy duty for Geyser & Air Conditioner complete all as specified and directed by Engr-in-charge.Make :- LEADER / HAVELLS / LEGRAND |
| 115 | Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surface conduit as directed |
| 116 | M&L for point wiring complete with 6 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 volts drawn in and including concealed non metalic PVC rigid conduit (ISI Marked) medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes terminated in existing sunken boxes including cutting chases in walls for conduits and making good disturbed surfaces of wall in CM 1:3 for mounting switches, sockets, fan regulator, covered with including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 2.5 Sqmm PVC insulated solidcopper conductor wire as earth continuity to common earth and connecting to earth dolly for power point on independent board complete all as specified and directed by Engineer-in-Charge.Make of cable :- Havells, Finolex, Gloster & L&TMake of conduit :- Supreme, Prince, Kalinga |
| 117 | AMC for ,servicing ,maintanence,repairing completeforPackage type Air conditioning plant of capacity 5.5 TR condensing unit ,Model :-DPA661R1 ,Make Blue starand kept it in 100% serviceable condition at all times with temperature/ humidity control (temperature24 degree +/- 2 degre with RH 55% +/- 5%) inEquiptment roomatAF station Thane Site \"P\" .The following scope of work including the above work. (No of units-2 nos, 1 nos running one stand by)(i)Testing,Checking ,servicing the indoor and out door units,Fresh air duct and return air ducts, all the filter, dumper, grill, electric control panel, Intelligent Microprocessor controller complete.(ii)Checking and serviceable all controlling equiptment, Push button , ON -OFF switch , Selector switch on PLC Panels for various mode of operation.. (iii)checking all the connection of cables end termination for any damge or Loose connection . (iv) Checking of compressour ,condensing coil, Solenoid valves ,auto control switch, Automation system. (v) Checkingthe pressure of Condensing gas and if required charging the gas. (vi) Checking of allinsulating material and repair/replace .(vii) ChekcingFresh air /Return duct,dumper,Grill, repair/maintanence/Replace if needed.(viii) Chekinginstallation of equiptmentand repair if found unserviceable. Note: (a)Spares for repair including Gas will be measured and paid seperatly in respectively items.(b)Serviceing to be done every month, if additional vist required the saame will be born by contractor in his own cost. |
| 118 | Supply and fixing in replacement ofPCB circit for intelligent cooling ambient sensor suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star. |
| 119 | Supply and fixing in replacement of thermostate suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star. |
| 120 | Supply and fixing in replacement of Propeller type PVC blade for condenser blower suitable for 5.5 AC plantall as specified and directed by Engineer-in-Charge.Make Blue star. |
| 121 | Supply and fixing in replacement of Non Woven Polyster Midea Enclosed by HDPE mesh Filter suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star. |
| 122 | M and Lfor dismantling the indoor and outdoor units of Air conditioner Window/Split type completely, reinstalled in new location ,including connection commissioning, necessary post achorage bolts complete all as directed as specified by Engineer-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail