Construction Of 09 ( Nine ) Nos Small Bore Deep Tube Well Including Extension Of Pipeline, Fhtc With Post And Platform As Per Aap 2020-21, 2021-22 And 2022-23 Under Jjm Under Dws Sub Division Teliamura ( Gr-Vi ) ( 2Nd Call ) . Construction Of 09 ( N
Tender Overview
Project Description
Construction Of 09 ( Nine ) Nos Small Bore Deep Tube Well Including Extension Of Pipeline, Fhtc With Post And Platform As Per Aap 2020-21, 2021-22 And 2022-23 Under Jjm Under Dws Sub Division Teliamura ( Gr-Vi ) ( 2Nd Call ) . Construction Of 09 ( Nine ) Nos Small Bore Deep Tube Well Including Extension Of Pipeline, Fhtc With Post And Platform As Per Aap 2020-21, 2021-22 And 2022-23 Under Jjm Under Dws Sub Division Teliamura ( Gr-Vi ) ( 2Nd Call ) .
BOQ
| Sl. No. | Item Description |
| 1 | Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at various suitable levels, preservation of samples in polythene bags / sample boxes and disposal of excess soil or mud, including the cost for water etc. as required to maintain the pilot hole properly as per specification and direction of the Engineer - in - charge.a) 100 mm dia |
| 2 | Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means, disposal of excess soil or mud, including the cost for water etc. as required to maintain the bore hole properly as per specification and direction of the Engineer - in - charge.i) From 100 mm dia pilot hole to 300 mm bore hole |
| 3 | Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per specification and direction of the Engineer - in - charge. |
| 4 | Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge.A) \"CM\" Casing pipe |
| 5 | i) 150mm dia |
| 6 | ii) 100 mm dia |
| 7 | B) \"RS\" pipe,i) 100 mmdia, |
| 8 | Providing and fixing of UPVC reducer suitable for UPVC \"CM\" casing or \"CS\" casing or \"RS\" pipes as per specification and direction of the Engineer - in - charge. (i) 150x100 mm dia |
| 9 | Providing and fixing of UPVC end cap / well cap suitable for UPVC \"CM\" casing or \"CS\" casing or \"RS\" pipes as per specification and direction of the Engineer - in - charge. (i) 100 mm dia |
| 10 | Providing and shrouding of the deep tube well assembly with washed pea gravels ( 2.0 - 4.75 mm effective size ) as per specification ( IS : 4097) and direction of the Engineer - in - charge.A. with contractor\"s rig(i) Per gravels obtained from Durgapur, West Bengal |
| 11 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- a) All work upto plinth level: 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brickaggregate of 20 mm nominal size) |
| 12 | Providing and laying in positioncement concrete specified gradeexcluding the cost of centring, shuttering, - a) All work upto plinth level: 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brickaggregate of 20 mm nominal size) |
| 13 | Centering shuttering including struttings, propping etc. and removal of form work for:i) Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.i) Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | 12 mm cement plaster of mixi) Cement mortar 1:4 (1 cement : 4 fine sand) |
| 16 | Neat cement punning |
| 17 | Providing and fixing of housing clamp ( made with 12 mm thick MS sheet ) along with well cap (made with 10 mm thick MS sheet ) with necessary arrangements for SBDTW as per specification and direction of the Engineer - in - charge.iii) 150 mm dia |
| 18 | Supplying and fitting fixing of single phase motor set 2HP, head (as per requirement),160 to 220 V, 50hz At Various location in/c. trail run as per specification and direction of the Engineer-in-charge. |
| 19 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. |
| 20 | Providing and fixing C.I. non-return valveofapproved quality as perof CPWD specification and direction of the Engineer - in - charge. i) 50mm dia |
| 21 | Labour cost of lowering of 2HP/3HP submersible pump with motor in/c column pipe assembly & transportation charges from workshop/office to site in/c testing |
| 22 | Supplying and fitting fixing of panel box of MS sheet with locking arrangement suitable for arrangement of all electrical accessories inside the box including service connection within 50.00 mtr length from I.T line with roof for rain water protection and 4 (four) Nos. stant by R.C.C work in all respect as per direction of the Engineer-in-charge. |
| 23 | Supplying and fitting fixing of single phase motor starter panel unit 3.0 HP / 2.0 HP capacity comprise with 2 pole unit conductor, over load rely, capacitors, volt meter, amp meter of BCH/L&T make with necessary copper wire etc. complete as per direction of the Engineer-in-charge |
| 24 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-incharge.I) 32 amps |
| 25 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge. i) 2.50 sq mm |
| 26 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in -charge.A. For UPVC pipes in new worka. In all kinds of soili) For pipes not exceeding 90 mm dia. |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 28 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 29 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of theEngineer - in - charge. A) External Worki) 15 mmdia. nominalbore |
| 30 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in - charge (cost of earth work and fittings will be paid separately). |
| 31 | (i) 15 mm dia |
| 32 | (ii) 20 mm dia |
| 33 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 34 | ii) 50 mm OD |
| 35 | i) 40 mm OD |
| 36 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 37 | i) 15mm dia |
| 38 | ii) 20 mm dia |
| 39 | iii) 40 mm dia |
| 40 | iv) 50 mm dia |
| 41 | Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge |
| 42 | i) 15x15x15x mm dia |
| 43 | v) 40x40x40 mm dia |
| 44 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 45 | i) 40x15 mm dia |
| 46 | i) 20x15 mm dia |
| 47 | ii) 40x50 mm dia |
| 48 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. |
| 49 | i) 15 mm dia. |
| 50 | iii) 20 mm dia. |
| 51 | v) 40 mm dia. |
| 52 | Providing and fixing of G.I. socket as per CPWD specification and direction of the Engineer-in-charge. |
| 53 | i) 15 mm dia. |
| 54 | v) 40 mm dia. |
| 55 | Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. completeas perCPWD specification and direction of the Engineer - in - charge. |
| 56 | ii) 40 mm dia. |
| 57 | Providing and fixing G.I. Nipple of medium class as perCPWD specification and direction of the Engineer - in - charge. |
| 58 | 15 mmdia75 mm long |
| 59 | i) 15 mmdia150 mm long |
| 60 | Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge. |
| 61 | 10 mm nominal bore |
| 62 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge. |
| 63 | 15 mm dia PVC /plastic bib cock |
| 64 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cementconforming to IS : 14182 including testing of joints complete as perCPWD specification and direction of the Engineer - in - charge. |
| 65 | i) 40 mm dia |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender