Tender For Advanced Stereo Zoom Microscope With Camera And Software Go Through Tender Notice. , Advanced Stereo Zoom Microscope With Photo Capturing Facility Specification : * Optics : Apochromatically Corrected Parallel Stereo Optics System With Maximu
Tender Overview
Project Description
Tender For Advanced Stereo Zoom Microscope With Camera And Software Go Through Tender Notice. , Advanced Stereo Zoom Microscope With Photo Capturing Facility Specification : * Optics : Apochromatically Corrected Parallel Stereo Optics System With Maximum Possible Resolution 1000 Lp / Mm * Zoom Range : 20 : 1 Or Better With Selectable Electronic Zoom Magnifications Range 0.47X – 15X With Motorized Focus. * Eyepiece : Plan Grade 10X Wider Field Of Eyepiece With Minimum Of 23Mm Fov * Magnification Range : 4.7X To 150X Or Better @ 10X Eyepiece With 1X Objective Lens. * Objective Lenses : Objective Plan Apochromatic Grade - 1.0X Fwd 60 Mm And 0.63X Fwd 81 Mm * Binocular Photo Tube: Motorized Phototube With 100% Light For Camera Or 100% Light For Eye * Double Iris Diaphragm : To Increase Depth Of Field To View Three Dimensional Objects. * Real Time Digital Display & Screen Controls: For Magnifications, Resolution, Depth Of Field And Object Field Of View Of The System. * Base: Transillumination, 90 White-Light Led Transmitted Light, Brightness Knob, And 3 Position Turret For: 1. Bright Field Plus And Oblique-Light Contrast By Shiftable Diaphragm 2. Homogenous Bright Field. 3. All-Side Dark Field, Also Unilateral By Movable Diaphragm; Incl. Glass Plate, Df Insert Diaphragm, * Light Source With Gooseneck And Ringlight: Cold Led Light Guide Having Up To 600Lm Light Flux, Ca. 6200K Color Temperature, Control Of Intensity And 6 Memory Cells By Turn-Push Knob. Min. 50, 000 Operating Hours .Gooseneck And Ring Light Have To Be Provided * Nosepeice : Coded ( Readable Through Pc ) Multiple Objective Turret To Hold 3 Objective Lenses: * High Resolution Scientific Digital Camera : Scientific Grade High Sensitivity Digital Camera With Usb 3 & Usb 2 Cables To Enable Direct Fast Interfacing With Pc. * Live Image Resolution : Minimum 5.0 Million Pixels On Pc Monitor & 12 Bit Color Depth. Selectable Frame Transfer Rate With Max. Resolution =35 Frames / Sec. Or Better. Pixel Size 3.45 X 3.45 ?M. Chip Size Equivalent To 2 / 3”. Dynamic Range >4500 : 1. Integration Time : 0.1 Ms To 4 Sec. Or Better. Temperature Stability @25°C For Ambient Temperatures Between 18°C And 30°C. Full Well Capacity : = Approx. 10, 000 E. Live R-G-B Spectral Intensity Display Or Optimum Control Of Camera. * Basic Image Analysis Software :. Image Acquisition And Processing Under Windows 10 X64. User Interface Configurable, Control Of The Microscope Systems And Components - Module Measurement - Module Multi Channel - Module Panorama – Module Extended Focus – Module Z- Stack. * Microscope, Camera & Software : All Should Be From Same Manufacturer
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Apr-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-Apr-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Advanced Stereo zoom Microscope with photo capturing facility Specification :* Optics : Apochromatically corrected parallel stereo optics system with Maximum PossibleResolution 1000 LP/mm* Zoom range : 20 : 1 or better with selectable Electronic Zoom Magnifications Range 0.47x – 15xwith motorized focus.* Eyepiece : Plan grade 10x wider field of eyepiece with minimum of 23mm FOV* Magnification range : 4.7x to 150x or better @ 10x eyepiece with 1x objective lens.* Objective lenses : Objective Plan Apochromatic grade - 1.0x FWD 60 mm and 0.63x FWD 81 mm* Binocular Photo Tube: Motorized phototube with 100% light for camera or 100% light for eye* Double iris diaphragm : To increase depth of field to view three dimensional objects.* Real time digital display & screen controls: For magnifications, resolution, depth of field and objectfield of view of the system.* Base: Transillumination, 90 white-light LED transmitted light, brightness knob, and 3 positionturret for: 1. Bright Field plus and oblique-light contrast by shiftable diaphragm 2. homogenousbright field. 3. all-side dark field, also unilateral by movable diaphragm; incl. glass plate, DF insertdiaphragm,* Light Source with gooseneck and ringlight: Cold LED Light guide having up to 600lm light flux, ca.6200K color temperature, control of intensity and 6 memory cells by turn-push knob. min. 50,000operating hours .Gooseneck and ring light have to be provided* Nosepeice : Coded (Readable through PC) Multiple Objective turret to hold 3 objective lenses:* High Resolution Scientific Digital Camera : Scientific grade high sensitivity digital camera withUSB 3 & USB 2 cables to enable direct fast interfacing with PC.* Live image resolution : Minimum 5.0 million pixels on PC monitor & 12 bit color depth. Selectableframe transfer rate with Max. Resolution =35 frames/sec. or better. Pixel size 3.45 x 3.45 µm. Chipsize equivalent to 2/3”. Dynamic Range >4500 : 1. Integration Time : 0.1 ms to 4 sec. or better.Temperature stability @25°C for ambient temperatures between 18°C and 30°C. Full well capacity := Approx. 10,000 e. Live R-G-B Spectral Intensity display or optimum control of camera.* Basic Image Analysis software :. Image acquisition and processing under Windows 10 x64. Userinterface configurable, control of the microscope systems and components - Module Measurement- Module Multi Channel - Module Panorama – Module Extended focus – Module Z- Stack.* Microscope, Camera & Software : All should be from same manufacturer |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender