Development Works In Elcot Approach Road Development Works In Elcot Approach Road
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Apr 2022
0 days left
EMD
45000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Development Works In Elcot Approach Road Development Works In Elcot Approach Road
BOQ
| Sl. No. | Item Description |
| 1 | Removing and clearing away the existing concrete block laid in road divider wall and stacking as per instructions of TPCL officials. (Debris materials will be transported and dumped in Coimbatore corporation designated area and the quoted rate includes removing and transporting of debrisoutside the campus) |
| 2 | Earth work open excavation in all soils and sub -soils and to full depth as may be directed and depositing the excavated earth with a lead of 10 mts within the compound in places shown by the TPCL officers and clearing and levelling the site ,etc., complete complying with standard specification. |
| 3 | Supplying & filling in foundation, etc., with filling river sand / Msand in layers of not more than 10 cm thick well-watered, rammed and consolidated etc., complete complying with standard specification and as directed by the TPCL officials. |
| 4 | Plain cement concrete 1:5:10 (One Cement ,Five sand and Ten hard broken stone jelly) using 40 mm guage hard broken granite stone jelly for foundation laid in layers of not more than 10 cm thick well rammed, consolidated and curing etc., complete complying with standard specification. |
| 5 | Masonry Work in cement mortar 1:5 (One cement and five sand ) using Fly Ash bricks of size 230 x110 x70 mm -virtually the bricks shall be sound compact and uniform in shape free from visible cracks warpage flaws and organic matter ,the bricks shall be solid with frog on one of its bearing side. class designation not less than 35 kg.sq cm an average compressive strength in CM 1:5 (one cement and Five -including neat finishing ,curing etc., complete complying with standard specification |
| 6 | Plastering with Cement mortar 1 : 5 ( one cement and five sand ) 12 mm thick in foudation complying with standard specifications. |
| 7 | Supplying & fixing the following dia of G.I Pipes (A -class) as per ISI specification (above divider wall) in Centre Median and packing of vertical pipe at every 3 m interval by cement concrete 1: 2: 4 mix (Size of Cement concrete packing -230 x 150 x150 mm) in front of Tidel Park as per instructions of TPCL officials. |
| 8 | a) GI - A class pipe -Top Line and Verticals at 3.00 Metre c/c - 40 mm dia |
| 9 | b) GI- A class Pipe - Bottom Line - 25 mm dia |
| 10 | Supplying and filling RED EARTH for centre median with in layers, well-watered, rammed and consolidated complying with standard specification etc., complete including stacking for Pre-Measurements.In between road divider wall etc., |
| 11 | Supplying and filling EARTH for centre median with in layers, well-watered, rammed and consolidated complying with standard specification etc., complete including stacking for Pre-Measurements.In between road divider wall etc., |
| 12 | Supplying and paintingthe kerb walls with two coats of cement paints over one coat of cement primer as instructed byTPCL officers including preparation of surface curing etc., complete in all walls complying with standard specifications (The colour and shade of the cement paint shall be got approved by the TPCL officials) |
| 13 | Painting of new iron workswith two coats of best approved first quality and colour of synthetic enamel paint 2 coat over the red oxide priming 2 coat in allincluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the TPCL Engineer before use on works.) |
| 14 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading andsupplying & fixingnecessary PVC specials using PVC adhesives including necessary earth work excavations , etc., to complete complying with standard specifications.The PVC pipes and specials shall be got approved by TPCL before use on works. |
| 15 | a) In the Development works in Elcot approach Road portion |
| 16 | i) 75 mm dia |
| 17 | ii)40 mm dia |
| 18 | ii)25 mm dia |
| 19 | b) For connectionto Main line From TPCL to Centre median |
| 20 | i) 75 mm dia |
| 21 | Supplying and fixing in position first quality and approved variety of PVC Ball Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications .The valves to be used on work shall be got approved by the TPCL before use on work. |
| 22 | a) 75 mm dia |
| 23 | c)40 mm dia |
| 24 | Fittings |
| 25 | Landscaping work |
| 26 | Plumeria/ Mara arali 4\" |
| 27 | Mahogany tree 4\" ht. |
| 28 | Ixora - 4 colours |
| 29 | Boganvilla4 colours |
| 30 | Farm yard manure |
| 31 | Neem cake |
| 32 | Labour for garden creation |
| 33 | Clearing of bushes in CMC compound wall and near railway line (Lumpsum) |
AI Tender Summary
Tender Timeline
Mar 28, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedApr 18, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedApr 19, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender