Underground Cable Laying Works For Electricity Supply Network At Permanent Colony Of Kameng Hydro Power Station, Neepco, Kimi, Arunachal Pradesh Part A Excavation Of Cable Trenches And Refilling The Trenches. Part B Laying Of 3.5Cx300 Sq. Mm And 3.5Cx5, kameng-Arunachal Pradesh

North Eastern Electric Power Corporation Limited-NEEPCO has published Underground Cable Laying Works For Electricity Supply Network At Permanent Colony Of Kameng Hydro Power Station, Neepco, Kimi, Arunachal Pradesh Part A Excavation Of Cable Trenches And Refilling The Trenches. Part B Laying Of 3.5Cx300 Sq. Mm And 3.5Cx5. Submission Date for this Tender is 25-04-2022. Cable Laying Tenders in kameng Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31625302
Underground Cable Laying Works For Electricity Supply Network At Permanent Colony Of Kameng Hydro Power Station, Neepco, Kimi, Arunachal Pradesh Part A Excavation Of Cable Trenches And Refilling The Trenches. Part B Laying Of 3.5Cx300 Sq. Mm And 3.5Cx5
Open Tender
Indian
Arunachal Pradesh
kameng
25-04-2022

Tender Details

Underground Cable Laying Works For Electricity Supply Network At Permanent Colony Of Kameng Hydro Power Station, Neepco, Kimi, Arunachal Pradesh Part A Excavation Of Cable Trenches And Refilling The Trenches. Part B Laying Of 3.5Cx300 Sq. Mm And 3.5Cx50 Sq. Mm Armoured Pvc Insulated And Pvc Sheathed Or Xlpe Power Cable Of 1.1 Kv Grade Including Sand Cushioning, Protective Covering And Suppl

Key Value

Document Fees
INR 1000 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Underground Cable Laying and associated excavation of Cable trenches at Permanent Colony, Kimi
Sl. No. Item Description
1Excavation for following Cable trenches excluding sand cushioning and protective covering but refilling the trench as required for cable size 3.5CX300 sq.mm. Trenches shall not be less than 750 ~ 800 mm deep & 300 mm wide for single and multiple LV service connection cables, and the trench width shall be increased where more than two LV feeder or service connection cables are laid together, clearance should be provided in proportion and site conditions as per IS specification. (Drawings enclosed)
2Cable trench lengthfor 10 no. of Cables
3Cable trench length for 9 no. of Cables
4Cable trench length for 8 no. of Cables
5Cable trench length for 7 no. of Cables
6Cable trench length for 6 no. of Cables
7Cable trench length for 5 no. of Cables
8Cable trench length for 4 no. of Cables
9Cable trench length for 3 no. of Cables
10Cable trench length for 2 no. of Cables
11Cable trench length for 1 no. of Cables
12Excavation for following Cable trenches excluding sand cushioning and protective covering and refilling the trench as required for cable size 3.5CX50 sq.mm. Trenches shall not be less than 7500 ~ 800 mm deep & 300 mm wide for single and multiple LV service connection cables, and the trench width shall be increased where more than two LV feeder or service connection cables are laid together clearance should be provided in proportion and site conditions as per IS specification. (Drawings enclosed)
13Cable trench lengthfor 05 no. of Cables
14Cable trench length for 04 no. of Cables
15Cable trench length for 03 no. of Cables
16Cable trench length for 02 no. of Cables
17Cable trench length for 01 no. of Cables
18Cable trench type-I for 10 no. of Cables Laying of Ten (10) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 60 meter approx) 3.5CX300 Sq. mm
19Cable trench type-II for 09 no. of Cables Laying of Nine (09) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 52 meter approx) 3.5CX300 Sq. mm
20Cable trench type-III for 08 no. of Cables Laying of Eight (08) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 68 meter approx) 3.5CX300 Sq. mm
21Cable trench type-IV for 07 no. of Cables Laying of Seven (07) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 120 meter approx) 3.5CX300 Sq. mm
22Cable trench type-V for 06 no. of Cables Laying of Six (06) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 60 meter approx) 3.5CX300 Sq. mm
23Cable trench type-VI for 05 no. of Cables Laying of Five (05) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 70 meter approx) 3.5CX300 Sq. mm
24Cable trench type-VII for 04 no. of Cables Laying of Four (04) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. 3.5CX300 Sq. mm
25Cable trench type-VIII for 03 no. of Cables Laying of Three (03) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 114 meter approx) 3.5CX300 Sq. mm
26Cable trench type-IX for 02 no. of Cables Laying of Two (02) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 56 meter approx) 3.5CX300 Sq. mm
27Cable trench type-X for 01 no. of Cables Laying of one (01) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 466 meter approx) 3.5CX300 Sq. mm
28Cable trench type-I-A for 05 no. of Cables Laying of Five (05) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 3 meter approx) 3.5CX50 sq. mm
29Cable trench type-II-A for 04 no. of Cables Laying of Four (04) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 52 meter approx) 3.5CX50 sq. mm
30Cable trench type-III-A for 03 no. of Cables Laying of one (01) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 126 meter approx) 3.5CX50 sq. mm
31Cable trench type-IV-A for 02 no. of Cables Laying of Two (02) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 357 meter approx) 3.5CX50 sq. mm
32Cable trench type-V-A for 01 no. of Cables Laying of one (01) no. PVC insulated and PVC sheathed /XLPE Power Cable of 1.1 kV grade of following size direct in the existing excavated cable trench including sand cushioning, protective covering etc as required. (Length of each cable 1528 meter approx) 3.5CX50 sq. mm
33Cable Laying type-I-B Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 3.5CX50 sq. mm(Clamped with 40X3 mm MS flat clamp)
34Cable Laying type-I-B Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 3.5CX 300 sq. mm(Clamped with 25X3 mm MS flat clamp)
35Cable Laying type-II-B Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5CX50 sq. mm
36Cable Laying type-II-B Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5CX 300 sq. mm
37Miscellaneous
38Making Cable joint with straight through cable joint of following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (jointing kit will be provided by NEEPCO) 3.5C X 50 sq.mm
39Making Cable joint with straight through cable joint of following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (jointing kit will be provided by NEEPCO) 3.5C x 300 sq.mm
40Supply and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription (DANGER 440 V) in Red colour there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
41EARTHING
42Supply & commissioning of Earthing with G.I. earth pipe 4.5-metre-long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
43Supply and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut-bolt & spring washer spaced at 50 mm)
44Demolishing cement concrete 1:3:6 or richer including refilling with the excavated materials after fixing the pipe for cable entry.
45Laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required 40 mm dia metre
46Laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required 100 mm dia metre
47Providing 15mm thick cement plaster of mix 1:4 (1 cement: 4 fine sand) at all levels.
48Transportation of Cable Drums from central store area to cable laying locations(approx. 200 Mtr) & making all necessary arrangement of hydraulic drum pedestals with suitable provisions of braking the drum and warming of cables, if required, before laying to protect insulation & protective covering, cable stocking with pulling eye should be used for pulling of cables.
49Suitable fabrication of 600 mm wide G.I. Cable tray (Provided) as per site requirement for crossing over drains & water stream along the culvert with G.I. Pipe (Provided) supports with 40 mm G.I. saddles including Nuts & Bolts as per requirements.
50Supply of materials by the Contractor
511.5" or 40 mm Dia Medium Duty B-Class GI Pipe
521.5" or 40 mm Dia Heavy Duty C-Class GI Pipe
534" or 100 mm Dia Heavy Duty C-Class GI Pipe
54GI saddle clamp for 40 mm GI Pipe
55Screws and PVC fastener
56Freight Charges of the above supplied materials
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail