Tender For Laboratory Items ( Part-1 ) - Beta-Hcg, Ca-125, Qcv ( Instrument ) Qcv ( Instrument ) , Ck-Mb, Cortisol, D-Dimer Exc. Ii, Dengue Ns1 / Igm / Igg, F Psa, Ferrittin, Fsh, Ft3, Ft4, Ige, Lh, Nt-Pro Bnb-Ii, Psa, T3, T4, Tpsa, Troponin I, Tsh, Vi
Tender Overview
Project Description
Tender For Laboratory Items ( Part-1 ) - Beta-Hcg, Ca-125, Qcv ( Instrument ) Qcv ( Instrument ) , Ck-Mb, Cortisol, D-Dimer Exc. Ii, Dengue Ns1 / Igm / Igg, F Psa, Ferrittin, Fsh, Ft3, Ft4, Ige, Lh, Nt-Pro Bnb-Ii, Psa, T3, T4, Tpsa, Troponin I, Tsh, Vitamin-D, Acculyte Reagent, Arterial Blood Collection Syringe Ca+Lh-80 Iu 3Ml, Multilevel Src For Opti Cca Ts2, Optt-Cca Cassettes , ( E-Ca ) Abg, For Opti Cca Ts2, Bottle Gas For Opti Cca Ts2, Thb Calibraator For Opti Cca Ts2, Printer Roll For Opti Cca Ts2, Hba1c Kit For Qua-Lab Analyser, Albumine Estimation Kit, Alanine Transaminase Estimation Kit ( Sgpt / Alt ) , Ifcc, Without Pyridoxal Phosphate Method, Alknie Phosphatase Estimation Kit, Base On Alp-Amp Method., Amylase Estimation Kit, Cnp-G3 Kinetic Method Cnp-G3 Kinetic Method Cnp-G3 Kinetic Method Cnp-G3 Kinetic Method Cnp-G3 Kinetic Method, Aspirate Transaminase Estimation Kit ( Sgot / Ast ) , Base On Ifcc, Without Pyridoxal Phosphate Method, Auto-Wash Solution, Concentrated Auto Wash Solution For Use Erba Em 360 Auto Analyzer., Bilirubin Direct Estimation Kit, Base On Diazo, Walter & Gerarde Method, Bilirubin Total Estimation Kit, Base On Diazo, Walter & Gerarde Method, Calcium Esstimation Kit Base On Arsenazo Iii Method, End-Pointcalcium Esstimation Kit Base On Arsenazo Iii Method, End-Pointcalcium Esstimation Kit Base On Arsenazo Iii Method, End-Pointcalcium Esstimation Kit Base On Arsenazo Iii Method, End-Point, Cholesterol Estimation Kit, Chod-Pap Method, Base On Cholesterol Esterase, Cholesterol Oxidase And Peroxidase, Endpoint, Ck-Mb Estimation Kit, Immunoinhibation Base On Method Creatine Kinase Mb Isoenzyme Estimation Kit, Kinetic, With N-Acetyl-Cysteine, Adp, Hexokinase, G6pd, Nadp, Ck-Nac Estimation Kit Base On Creatine Kinase Nac Isoenzyme Estimation Kit, Kinetic, With N-Acetyl-Cysteine, Adp, Hexokinase, G6pd, Nadpck-Nac Estimation Kit Base On Creatine Kinase Nac Isoenzyme Estimation Kit, Kinetic, With N-Acetyl-Cysteine, Adp, Hexokinase, G6pd, Nadpck-Nac Estimation Kit Base On Creatine Kinase Nac Isoenzyme Estimation Kit, Kinetic, With N-Acetyl-Cysteine, Adp, Hexokinase, G6pd, Nadpck-Nac Estimation Kit Base On Creatine Kinase Nac Isoenzyme Estimation Kit, Kinetic, With N-Acetyl-Cysteine, Adp, Hexokinase, G6pd, Nadp, Creatinine Enzymatic Estimation Kit, Enzymatic Method Enzymatic Method Enzymatic Method Enzymatic Method, Creatinineestimation Kit , Base On Alkaline Picrate. Fixed Time Methodbase On Alkaline Picrate. Fixed Time Methodbase On Alkaline Picrate. Fixed Time Methodbase On Alkaline Picrate. Fixed Time Method, Crp Estimation Kit , With Calibrator Base On Antigen Antibody Reaction End Point Method, Direct Hdl Cholesterol Estimation Kit, Base On Direct Enzymatic Immunoinhibition Method. , Modified Polivinyle Sulfonic Acid & Pegme, Direct Ldl Cholesterol Estimation Kit Table Ready Use R1 & R2 Reagents With Calibrator. Direct Enzymatic Method. .Ldl Cholesterol Estimation Kit Table Ready Use R1 & R2 Reagents With Calibrator. Direct Enzymatic Method. .Ldl Cholesterol Estimation Kit Table Ready Use R1 & R2 Reagents With Calibrator. Direct Enzymatic Method. ., Fe ( Iron ) Estimation Kit With Calibrator, Iron+Uibc Is Binding Is Tibc, Ferrittin Estimation Kit, Measurement Of Antigen / Latex Method, Glusoce Estimation Kit, Based On Hexokinase And G6pd Enzymes, End-Point Method, Glucose Estimation Kit, Glucose Estimation Kit Based On God And Pap Enzymatic Methodglucose Estimation Kit Based On God And Pap Enzymatic Methodglucose Estimation Kit Based, On God And Pap Enzymatic Method, Hba1c Estimation Kit With Calibrator, Particle Enhanced Immunoturbidometry Test, Hba1c Is Determine Directly Without Masure Total Hemoglobin., Pm Kit For Em -360, Ldh Estimation Kit, Method Of Henry Etal To Use Pyruvare And Recomanadate By Dgkch Ifcc Uv - Kinetic Method., Lipase Estimation Kit, Enzymatic -Colorimetric Method., Micro Protein Estimation Kit, Single Reagents. Colorimetric End Point, Multi Calibrator For Clinical Chemistry., Phosphourus Estimation Kit, Quality Control Of Human Sera ( High Range ) Quality Control Of Human Sera ( High Range ) For Clinical Chemistry, Quality Control Of Human-Sera ( Normal Range ) Quality Control Of Human-Sera ( Normal Range ) For Clinical Chemistry, Sample Cup For Em-360 Transasia Instrument, Total Protein Estimation Kit , Biuret Method, Endpoint, Trigyceride Estimation Kit, Gpo Method, Base On Lipoprotein Lipase, Glycerol Kinase, Glycerol-3-Phosphase Oxidase, Peroxidase Endpoint, Uibc Estimation Kit, Tibc–Iron Binding Is Uibc, Urea Estimation Kit, Urease-Gldh Method , Fixed Time Method, , Uric Acid Estimation Kit Uricase Pod Method, , M Kit For Aqua D.I. Plant, M 53 D Dialuent, M 53 Lh Lyse, M53 Lh Leo 1, M53 Lh Leo 2, M53 Probe Cleanser, M-53 Hematology Human Control ( Normal, High, & Low ) , M-53 Hematology Calibrator, Abx Minidil, Abx Minoclair, Abx Minilysebio, Abx Miniclean, Hematology Human Control ( Normal, High, & Low ) , Hematology Calibrator, Sheath For Spincell 5 Series, Detergent For Spincell 5 Series, Dialuent For Spincell 5 Series, Lyse Reagent For Spincell 5 Series, Cleaning Solution, Hematology Human Control ( Normal, High, & Low ) , Hematology Calibrator, Reticulocyte Reagent ( Vacutainer ) For Spincell 5 Series, Bd Bactec Standard / 10 Aerobic / F Culture Vials ( Plastic ) , Bd Bactec Peds Plus / F Culture Vials ( Plastic ) , Acetone Powder, Acid Phosphates Estimation Kit, Alanine Transaminase Kit ( Sgpt / Alt ) , , Albumine Estimation Kit, Alkanie Phosphatase Kit, Amylase Estimation Kit, Aspirate Transaminase Kit ( Sgot / Ast ) Method €“Modified Ifcc Uv Kinetic Linearity U / L Precise Sensitivity- 2 U / L Incubation Time 1 ( Delay ) +2 Or 3 Min At 37, Bilirubin Direct And Total Single Reagent Estimation Kit Method €“ Jendrassik Method Linearity Up To 25 Mg / Dl Precise Sensitivity- 0.10 Mg / Dl, Bilirubin Direct And Total Single Reagent Estimation Kit Method €“ Modified Bergh & Muller Method Single ( Mono ) Reagent For Total Bilirubin Estimation And Single ( Mono ) Reagent For Direct Bilirubin Estimation Linearity 20 Mg / Dl Precise Sensitivity- 0.10 Mg / Dl Reagent Use Without Need For Manual Mixing Of Reagents And Without Change In Reagent And Sample Proportions., Calcium Kit Estimation Kit Method Arsenazo Iii Mono Vial Reagent Pack Linearity Up To 15 Mg / Dl Precise Sensitivity- 1 Mg / Dl Incubation Time 1 To 2 Min At 20 To 37, Cholesterol ( Total ) Kit Method €“ Chod-Pap Enzymatic End Point Linearity 700 Mg / Dl Precise Sensitivity-3 Mg / Dl Incubation Time 5 Min At 37, Cholinesterase Kit Linearity U / L Precise Sensitivity- 0.04 Ku / Lprecise Sensitivity- 0.04 Ku / Lprecise Sensitivity- 0.04 Ku / Lprecise Sensitivity- 0.04 Ku / Lprecise Sensitivity- 0.04 Ku / L Liquid Stable Reagents Enzymatic - Kinetic Method. Dtnb , Butyryl Thiocholine Substrate Linearity ≫ 6000 U / L Compatible With Miura & Metrolab Fully Auto + Semi Auto Analysers. About 50 Ml. Packs., Ck-Mb Kit Method €“ Ifcc Uv Kinetic ( Dgkc ) Linearity Up To 1000 U / L Precise Sensitivity- 2 U / L Incubation Time 5 ( Delay ) + 5 Min At 37Centigrade Or 10 Min Rt, Ck-Nac Method €“ Ifcc Uv Kinetic ( Dgkc ) Linearity Up To 1000 U / L Precise Sensitivity- 1 U / L Incubation Time 3 / 5 ( Delay ) + 5 Min At 37Centigrade, Control ( Human ) For Ise Electrolyte Na, K, Cl, Control ( Human ) - Quality Control Human Sera For Clinical Chemistry ( High Range ) , Control ( Human ) - Quality Control Human Sera For Clinical Chemistry ( Normal Range ) , Control ( Human ) Of Ferrittin, Control ( Human ) Of T3, Control ( Human ) Of T4, Control ( Human ) Of Tsh, Creatinine Kit Single Reagent Kit , Not Required To Mix Method €“ Jaffe Modified Enzymatic Fix Time Kinetic Method €“ Jaffe Modified Enzymatic Fix Time Kinetic Linearity 25 Mg / Dl Precise Sensitivity-1 Mg / Dl No Interference With Bilirubin Up To 6 Mg / Dl, Creatinine Kit Method €“ Jaffe Enzymatic Fix Time Kinetic Method €“ Jaffe Enzymatic Fix Time Kinetic Single ( Mono ) Reagent For Estimation , And Ready To Use. Reagent Use Without Need For Manual Mixing Of Reagents And Without Change In Reagent And Sample Proportions.Reagent Use Without Need For Manual Mixing Of Reagents And Without Change In Reagent And Sample Proportions. Linearity 25 Mg / Dl Precise Sensitivity-1 Mg / Dl No Interference With Bilirubin Up To 6 Mg / Dl, De-Ionized Water With Conductivity Less Than 1 Micro Seamens With Centicuner. Nccls Type Ii Or Better, Direct Ldl Cholesterol Kit With Calibrator. Method €“ Direct Method Linearity 650 Iu / L Precise Sensitivity - 2 Mg / Dl, Ditrect Hdl Cholesterol Method €“ Direct Method Linearity Precise Sensitivity- 10 Mg / Dl L Incubation Time & Read Time In 3 Min., Elisa For Vitamin B12 Method €“ Elisa Analytical Sensitivity: 70.13 Pg / Ml At 2Sd Accuracy: Correlation Coefficient 0.9506 With A Reference Method, Elisa For Vitmin D Method €“ Elisa Analytical Sensitivity: 1.140 Ng / Ml At 2Sd, Elisa Kit For Ferrittin Method €“ Elisa Sensitivity: Detects Ferritin Levels As Low As 0.06 Ng / Ml At 2Sd Accuracy: R= 0.997 Against Reference Elisa By An External Lab, Elisa Kit For Thyroid Gland Stimulation Hormone Method-Elisa Linearity Precise Sensitivity 4 Pg / Mlprecise Sensitivity 4 Pg / Ml Sensitivity: Detects Tsh Levels As Low As0.035&Micro;Iu / Ml Specificity: No Cross Reactivity Detected With Related Hormones: Fsh, Lh And Hcg Linearity: 1:128 Dilution On 36 Iiu / Ml Sample, Elisa Kit For Free Thyroid Gland Tri- Iodothypomine.Elisa Kit For Free Thyroid Gland Tri- Iodothypomine. Method €“ Elisa Sensitivity: 0.98 Pg / Ml Accuracy: R=0.91, Elisa Kit For Free Thyroid Gland Tetra-Iodothypomineelisa Kit For Free Thyroid Gland Tetra-Iodothypomine Method €“ Elisa Sensitivity: 0.20Ng / Ml Accuracy: R=0.94, Elisa Kit For Thyroid Gland Tri- Iodothypomine.Elisa Kit For Thyroid Gland Tri- Iodothypomine. Method €“ Elisa Analytical Sensitivity: 173 Ng / Ml At 2-Sd Accuracy: Correlation Coefficient 0.99 With A Reference Method, Elisa Kit For Thyroid Gland Tetra-Iodothypomine Method Elisa Analytical Sensitivity: 176 &Micro;G / Dl At 2-Sd Accuracy: Correlation Coefficient 0.98 With A Reference Method, Ferrittin Single ( Mono ) Test Method €“ Latex Immuno Turbidometry Linearity Ug / L Precise Sensitivity- 5 U / L, Flow Cell Clean Solution, Fouchet’S Reagent, Glucose Kit Method €“ God-Pap Enzymatic Linearity 600 Mg / Dl Incubation Time 10- Min At 37 Or 15 Min At Rt, Hemocysteine Estimation Kits Method €“ Enzymatic Cycling Fix Time Kinetic Method Linearity Method €“ Enzymatic Cycling Fix Time Kinetic Method Linearity &Micro;Mol / L. &Micro;Mol / L. Precise Sensitivity:- 1 &Micro;Mol / L.Precise Sensitivity:- 1 &Micro;Mol / L. Reagents. R1, R2, R3. Enzymatic Uv Kinetic 340 Nm Method. Calibrators Must Be Supplied With Kit Having Reconsituted Open Bottle Stability Of 30 Days., Ldh Kits Method €“ Ifcc Linearity U / L Precise Sensitivity- 10 Iu / L Incubation Time 1 ( Delay ) +2 Or 3 Min At 37, Lipase Kit With Calibrator. Method €“ Methyl Resorufin Fix Time Linearity 250 Iu / L Incubation Time 1 ( Delay ) +1 Min. Read Tim At 37, Multi Calibrator ( Human ) , Natural Detergent For Lab-Ware, Rothras Powder, Ketonbody Detection, Total Protein Method €“ Biuret- End Pointmethod €“ Biuret- End Point Linearity Up To 12 Gm / Dl Precise Sensitivity -0.6 Gm / Dl, Triglyceride Kit Method €“God-Pod Enzymatic, Based On Lipoprotein Lipase, Glycerol Kinase, Glycerol-3-Phosphase Oxidase, Peroxidase End-Point Method €“God-Pod Enzymatic, Based On Lipoprotein Lipase, Glycerol Kinase, Glycerol-3-Phosphase Oxidase, Peroxidase End-Point Linearity 1000 Mg / Dl Precise Sensitivity 5 Mg / Dl Incubation Time 5- Min At 37 Or 15 Min At Rt Or 15 Min At Rt, Troponin I Card, Urea-Gldh Kit Method €“Gldh Uv Enzymatic Fix Time Kinetic Method €“Gldh Uv Enzymatic Fix Time Kinetic Linearity 300 Mg / Dl Precise Sensitivity-2 Mg / Dl Incubation Time 30 Second ( Delay ) +1 Min At 37, Uric Acid Kit Method €“ Uricase-Pod Linearity Mg / Dl Precise Sensitivity- 2 Mg / Dl Incubation Time 5 Min At 37 Or 10 Min On Rt, Uristrips For Glucose & Albumine, Uristrips For Glucose & Ketone Bodies, Anti Sera - H, Anti A1 Grouping Sera, Anti Ab, Anti Sera €“A 10 Ml Igg & Igm, Bovine Albumin, Coombs Sera ( Anti Human Globulin ) , Copper Sulphate Powder, Forhead Thermometer, Glucose Powder, Glucose Powder 200Gm, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, High Sensitivity Thermal Paper Rolls, Hiv Elisa 4Th Generation, Hiv Rapid Kit 4Th Generation, Micropore Tape, Micropore Tape, Micropore Tape, Normal Saline, Single Blood Bag Cpda, Temp. Chart For Blood Bank Refrigeratore Pempol, Thermal Printer Roll 110 Mm, Thermal Printer Roll 110 Mm, Tourniquet Belt, Tourniquit Bag With Cuff All Size, Tourniquit Bag With Cuff All Size, Anti B Blood Gr.Serum ( Monoclonal ) , 0.1 N Hcl, A.P.T.T., A.P.T.T., Acetone, Acetone Powder, Anti A Blood Grouping Serum ( Monoclonal ) , Anti Rh ( D ) Serum Human, Barium Chloride Powder, Barium Cloride Solution, Basic Fuschin Powder, Blood Collection Tube Edta Vaccute, Blood Collection Tube Edta K2 Non Vaccute, Blood Collection Tube Edta K3 Non Vaccute, Capillary Box, Capillary Box, Cidar Wood Oil, -, Citrate Blood Collection Tube, Concentrated Hcl, Control For Drabkin’S Solution 10 Ml, Coplin Jar, Coverslip Glass, Coverslip Long Glass, Dpx Bottle, Dpx Bottle, Drabkins Reagent, Esr Stand, Esr Tube Disposable, Esr Tube Glass, Esr Tube Glass, Falcipaum Detection Kit - Phrp Antigen - For Detection Falciparum, Field Stain A, Field Stain B, Filer Paper ( Whatsman ) , Fouchets Reagent, Glass Rode, Glass Rode, Glass Slide, Hb Pipette 20 Mm, Hb Pipette 20 Mm, Hb Square Tube, Hb Square Tube, Hemoglobin Pipette, Hemoglobin Pipette, Hemoglobin Tube, Hemoglobin Tube, Hydrochloric Acid 35 % Pure, Keto Strip, Malaria Card Test, Methanol, Microscope Lamp, Microscope Lamp, Nacl Powder, Natural Detergent For Lab-Ware, P.C.V. Tube, P.C.V. Tube, Potassium Dioxalate Powder, Ppottasium Dichromate Powder, Pt, Pt, Rapid H & E Stain, Reagent Strips For Estimating Albumin & Glucose In Urine, Reticulocyte Stain, Slide Cleaning Solution, Slide Cleaning Solution, Slide Storage Wooden Box, Slide Storage Wooden Box, Sodium Citrate Solution, Stain - Malarial Parasite Staining Kit, Urine Collection Bag, Urine Container, Urine Container Disposible, Urine Port Plastic, Uristrip For 10 Parameter, Xylene, Kit For Detection Of Hiv I & Ii Antibodies In Human Sera / Plasma-Simple Test Method, Agar Agar Powder, Albert Stain A, Albert Stain A, Antibiotic Disc - Amoxycillin + Clavulinic Acid ( 30=20 / 10 Micrograms ) , Antibiotic Disc - Cefaclor ( 30 Micrograms ) , Antibiotic Disc - Cefepime ( 30 Micrograms ) , Antibiotic Disc - Cefexime ( 5 Micrograms ) , Antibiotic Disc - Cefoxitin ( 30 Micrograms ) , Antibiotic Disc - Chloramphenicol ( 30 Micrograms ) , Antibiotic Disc - Lmipenem ( 10 Microgram ) , Antibiotic Disc - Ofloxacin ( 5 Microgram ) , Antibiotic Disc - Penicillin G ( 10 Units ) , Antibiotic Disc - Piperacillin ( 100 Micrograms ) , Antibiotic Disc - Piperacillin + Tazobactum ( 100 / 10 Micrograms ) , Antibiotic Disc - Tcarcillin + Clavulanic Acid ( 75 / 10 Micrograms ) , Antibiotic Disc - Ticarcillin ( 75 Micrograms ) , Antibiotic Disc - Vancomycin ( 30 M Icrograms ) , Antibiotic Disc Amoxycillin 20 Mcg And Clavulanic Acid 10Mcg, Antibiotic Disc- Azithromicin ( 15 M Crograms ) , Antibiotic Disc -Aztreonam 30 Mocrograms, Antibiotic Disc- Cefeperazone +Sulbactam ( 75 / 10 Micrograms ) , Antibiotic Disc -Cefepime + Tazobactum ( 30 / 10 Micrograms ) , Antibiotic Disc -Cefoperazone ( 75Micrograms ) , Antibiotic Disc Cefotaxime30 Mcg & Cefotaxime Clavulanic Acid 30 / 10Mcg, Antibiotic Disc -Cefpodoxime ( 10 Micgrams ) , Antibiotic Disc -Ceftazidime ( 30 Micrograms ) , Antibiotic Disc -Ceftazimide +Clavula Acid ( 30 / 10 Micrograms ) , Antibiotic Disc -Ceftizoxime ( 30 Micrograms ) , Antibiotic Disc- Ceftriaxone ( 30 Micrograms ) , Antibiotic Disc -Ceftriaxone + Sulbactam ( 30 / 15 Micrograms ) , Antibiotic Disc -Ceftriaxone +Tazobactum ( 30 / 10 Micrograms ) , Antibiotic Disc- Meropenem ( 10 Microgram ) , Antibiotic Disc -Norfloxacin ( 10 Microgram ) , Antibiotic Disc Piperacillin & Tazobactum Disc ( 100Mcg / 10Mcg ) , Antibiotic Disc- Polymixin B ( 300 Units ) , Antibiotic Disc_Tobramycin ( 10 Micrograms, Antibiotic Disc-Amikacin ( 30 Micrograms ) , Antibiotic Disc-Amoxycillin ( 5 Micrograms ) , Antibiotic Disc-Ampicillin ( 10 Micrograms ) , Antibiotic Disc-Ampicillin + Sulbacium ( 10 / 10 Micrograms ) , Antibiotic Disc-Cefotaxime ( 30 Micrograms ) , Antibiotic Disc-Cefuroxime ( 30 Micrograms ) , Antibiotic Disc-Cephalexin ( 30 Micrograms ) , Antibiotic Disc-Ciprofloxacin ( 5 Microgram ) , Antibiotic Disc-Clindam Ycin ( 2 Micrograms ) , Antibiotic Disc-Cotrimexazole ( Micrograms ) , Antibiotic Disc-Cotrimexazole ( Micrograms ) , Antibiotic Disc-Cotrimexazole ( Micrograms ) , Antibiotic Disc-Doxycyline ( 30 Microgram ) , Antibiotic Disc-Erythromycin ( 15 Microgram ) , Antibiotic Disc-Gentamicin ( 10 Microgram ) , Antibiotic Disc-Levofloxacin ( 5Microgram ) , Antibiotic Disc-Linezolid ( 30 Microgram ) , Antibiotic Disc-Nilidixic Acid ( Micrograms ) , Antibiotic Disc-Nilidixic Acid ( Micrograms ) , Antibiotic Disc-Nilidixic Acid ( Micrograms ) , Antibiotic Disc-Nitrofuraintoin ( Micrograms ) , Antibiotic Disc-Nitrofuraintoin ( Micrograms ) , Antibiotic Disc-Nitrofuraintoin ( Micrograms ) , Antibiotic Disc-Tetracycline ( 30 Micrograms ) , Antibiotic Disc-Tiecoplanin ( 30 Micrograms ) , Antibiotic Ring For Gram Negative Organism, Antibiotic Ring For Gram Positive Organism, Antibiotic Ring For Urinary Organism, Antibiotic Tetracycline Disc, Antisera-Salmonella 02 Antiserum, Antisera-Satmoneila 04 Antiserum, Antisera-Satmoneila 09Antiserum, Arobic Culture Vials Adult, Arobic Culture Vials Pediatric, Aso, Autoclavable Bottle For Culure, Autoclavable Bottle For Culure, Autoclavable Bottle For Culure, Autoclavable Bottle For Culure, Autoclavable Bottle For Culure, Autoclavable Bottle For Culure, Autoclavable Bottle For Media Preparation, Autoclavable Bottle For Media Preparation, Autoclave Label, Autoclave Label, Bile Esculine Agar, Blood Collection Tube Plain Non Vaccute, Blood Collection Tube Plain Vaccute, Chiller Rack ( 96 Hole ) , Concentrated H2so4, Controls For Chikungunya Elisa, Controls For Dengue Igm Elisa, Controls For Dengue Ns1 Elisa, Controls For Hepatitis A Igm Elisa, Controls For Hepatitis E Igm Elisa, Controls For Measles Igm Elisa, Cooked Meat Pieces, Crp, Crp, Disposable Petri Dish ( 100 Mm ) , Disposable Petri Dish ( 110 Mm ) , Disposable Petri Dish ( 110 Mm ) , Disposable Petri Dish ( 90 Mm ) , Disposable Sterile Container
BOQ
| Sl. No. | Item Title | Specification |
| 1 | BETA-HCG | Must be Single test kit available. Must be MLE bar coded on reagent kit. MLE Barcode read and Compatible with Vidas immunoassay analyzer of of BIOMÉRIEUX company. Where required TV1 must be > = the value indicatedon the kit label. kit supply with control/calibrator as per Vidas compitable. when required kit established (set) in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization.Must be Single test kit available. Must be MLE bar coded on reagent kit. MLE Barcode read and Compatible with Vidas immunoassay analyzer of of BIOMÉRIEUX company. Where required TV1 must be > = the value indicatedon the kit label. kit supply with control/calibrator as per Vidas compitable. when required kit established (set) in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. |
| 2 | CA-125 | As per above specification |
| 3 | QCV (Instrument)QCV (Instrument) | As per above specification |
| 4 | CK-MB | As per above specification |
| 5 | Cortisol | As per above specification |
| 6 | D-Dimer Exc. II | As per above specification |
| 7 | Dengue Ns1/IgM/IgG | As per above specification |
| 8 | F PSA | As per above specification |
| 9 | Ferrittin | As per above specification |
| 10 | FSH | As per above specification |
| 11 | FT3 | As per above specification |
| 12 | FT4 | As per above specification |
| 13 | IgE | As per above specification |
| 14 | LH | As per above specification |
| 15 | NT-PRO BNB-II | As per above specification |
| 16 | PSA | As per above specification |
| 17 | T3 | As per above specification |
| 18 | T4 | As per above specification |
| 19 | TPSA | As per above specification |
| 20 | TROPONIN I | As per above specification |
| 21 | TSH | As per above specification |
| 22 | VITAMIN-D | As per above specification |
| 23 | Acculyte Reagent | When required Calibration standard solution, Refill solution ,condition solution, De-proteinzer supply free of cost with kit .For compatible with ISE Base Electrolyte Analyser (3 Parameter) Model AFT-300. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. |
| 24 | Arterial blood collection syringe Ca+LH-80 iu 3ml | Syringe with screw cap. Compatible with OPTI CCA TS2 ABG instrument Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied. |
| 25 | Multilevel SRC for OPTI CCA TS2 | Compatible with OPTI CCA TS2 ABG instrument Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied. Supplier attached currently valid certificate of company authorization. |
| 26 | OPTT-CCA Cassettes ,(E-CA) ABG, for OPTI CCA TS2 | As per above |
| 27 | Bottle Gas for OPTI CCA TS2 | As per above |
| 28 | tHb calibraator for OPTI CCA TS2 | As per above |
| 29 | Printer Roll for OPTI CCA TS2 | As per above |
| 30 | HbA1C Kit for QUA-LAB analyser | Compatible with QUA-LAB analyser of EKF Dignostic compan,Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied,Supplier attached currently valid certificate of company authorization. |
| 31 | ALBUMINE ESTIMATION KIT | -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -Supplier must set parameter in EM-360 ,when we require to established new parameter.-authorization. -Supplier attached currently valid certificate of company authorization. -Supplier attached currently valid certificate of company authorization. -With tender attach Commercial Kit insert (literature) of the brand to be supplied. -Attached Kit literature shell be considered authentic legal document for verification of specifications. -If asked, renderer must show sealed commercially supplied kit for verification of specifications. -If asked, renderer must provide, free of charge, sealed commercially supplied kit for checking performance. -Kit literature must specify composition of reagents sufficient to check its conformance to accepted scientific literature. -All reagents must be in ready to use liquid form. -Expiry of reagents at 2-8 ‘C must be >=6 months from date of receipt. Kit protocol |
| 32 | ALANINE TRANSAMINASE ESTIMATION KIT (SGPT/ALT),IFCC,without Pyridoxal Phosphate method | As per above |
| 33 | ALKNIE PHOSPHATASE ESTIMATION KIT,base on ALP-AMP METHOD. | As per above |
| 34 | AMYLASE ESTIMATION KIT, CNP-G3 Kinetic method CNP-G3 Kinetic method CNP-G3 Kinetic method CNP-G3 Kinetic method CNP-G3 Kinetic method | As per above |
| 35 | ASPIRATE TRANSAMINASE ESTIMATION KIT (SGOT / AST ),Base on IFCC,without Pyridoxal Phosphate method | As per above |
| 36 | AUTO-WASH SOLUTION,Concentrated auto wash solution for use Erba Em 360 auto analyzer. | As per above |
| 37 | BILIRUBIN DIRECT ESTIMATION KIT,Base on DIAZO,Walter & Gerarde method | As per above |
| 38 | BILIRUBIN TOTAL ESTIMATION KIT,Base on DIAZO,Walter & Gerarde method | As per above |
| 39 | CALCIUM ESSTIMATION KIT BASE ON Arsenazo III method, End-PointCALCIUM ESSTIMATION KIT BASE ON Arsenazo III method, End-PointCALCIUM ESSTIMATION KIT BASE ON Arsenazo III method, End-PointCALCIUM ESSTIMATION KIT BASE ON Arsenazo III method, End-Point | As per above |
| 40 | CHOLESTEROL ESTIMATION KIT,CHOD-PAP method,Base on cholesterol esterase, cholesterol oxidase and peroxidase, EndPoint | As per above |
| 41 | CK-MB ESTIMATION KIT,IMMUNOINHIBATION base on method Creatine Kinase MB isoenzyme estimation kit, Kinetic, with N-acetyl-cysteine, ADP, Hexokinase, G6PD, NADP | As per above |
| 42 | CK-NAC ESTIMATION KIT base on Creatine Kinase NAC isoenzyme estimation kit, Kinetic, with N-acetyl-cysteine, ADP, Hexokinase, G6PD, NADPCK-NAC ESTIMATION KIT base on Creatine Kinase NAC isoenzyme estimation kit, Kinetic, with N-acetyl-cysteine, ADP, Hexokinase, G6PD, NADPCK-NAC ESTIMATION KIT base on Creatine Kinase NAC isoenzyme estimation kit, Kinetic, with N-acetyl-cysteine, ADP, Hexokinase, G6PD, NADPCK-NAC ESTIMATION KIT base on Creatine Kinase NAC isoenzyme estimation kit, Kinetic, with N-acetyl-cysteine, ADP, Hexokinase, G6PD, NADP | As per above |
| 43 | CREATININE ENZYMATIC estimation kit, Enzymatic Method Enzymatic Method Enzymatic Method Enzymatic Method | As per above |
| 44 | CREATININEESTIMATION KIT ,Base on Alkaline Picrate. Fixed Time MethodBase on Alkaline Picrate. Fixed Time MethodBase on Alkaline Picrate. Fixed Time MethodBase on Alkaline Picrate. Fixed Time Method | As per above |
| 45 | CRP ESTIMATION KIT ,with calibrator base on Antigen Antibody reaction end point method | As per above |
| 46 | DIRECT HDL CHOLESTEROL ESTIMATION KIT,Base on Direct Enzymatic Immunoinhibition Method. ,modified polivinyle sulfonic acid & PEGME | As per above |
| 47 | DIRECT LDL CHOLESTEROL ESTIMATION KIT table Ready use R1 & R2 Reagents with calibrator. Direct Enzymatic Method. .LDL CHOLESTEROL ESTIMATION KIT table Ready use R1 & R2 Reagents with calibrator. Direct Enzymatic Method. .LDL CHOLESTEROL ESTIMATION KIT table Ready use R1 & R2 Reagents with calibrator. Direct Enzymatic Method. . | As per above |
| 48 | FE(IRON) ESTIMATION KIT with calibrator,IRON+UIBC is binding is TIBC | As per above |
| 49 | FERRITTIN ESTIMATION KIT,Measurement of Antigen/latex method | As per above |
| 50 | GLUSOCE ESTIMATION KIT,based on Hexokinase and G6PD enzymes, End-Point Method | As per above |
| 51 | GLUCOSE ESTIMATION KIT,Glucose Estimation Kit based on GOD and PAP enzymatic MethodGlucose Estimation Kit based on GOD and PAP enzymatic MethodGlucose Estimation Kit based,on GOD and PAP enzymatic Method | As per above |
| 52 | HBA1C ESTIMATION KIT with calibrator,Particle enhanced Immunoturbidometry test, HbA1c is determine directly without masure total hemoglobin. | As per above |
| 53 | PM kit for EM -360 | As per above |
| 54 | LDH ESTIMATION KIT,Method of Henry etal to use Pyruvare and Recomanadate by DGKCH IFCC UV - Kinetic Method. | As per above |
| 55 | LIPASE ESTIMATION KIT,Enzymatic -Colorimetric Method. | As per above |
| 56 | MICRO PROTEIN ESTIMATION KIT,Single Reagents. Colorimetric End Point | As per above |
| 57 | MULTI CALIBRATOR for Clinical chemistry. | Attached Literature must show target values for Glucose, Urea, Creatinine, Cholesterol, Triglycerides, Total Protein and Albumin, Ca2+, Uric acid, Total Bilirubin, Direct Bilirubin, ALT, ALP, Amylase and GGT,Na+, K+. Package literature must certify that it is made from human blood free from common infectious agents.Package literature must certify that it is made from human blood free from common infectious agents.Material must be in lyophilised form with single vial <=5 ml size on reconstitution. Pack size must be quoted against price and must be mentioned in kit literature. Band name must be quoted against price and must be mentioned in kit literature. While supplying the QC material, required cold chain must be observed Other specification As per Annaxure No.5 Item no.1 |
| 58 | PHOSPHOURUS ESTIMATION KIT | -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -Supplier must set parameter in EM-360 ,when we require to established new parameter.-authorization. -Supplier attached currently valid certificate of company authorization. -Supplier attached currently valid certificate of company authorization. -With tender attach Commercial Kit insert (literature) of the brand to be supplied. -Attached Kit literature shell be considered authentic legal document for verification of specifications. -If asked, renderer must show sealed commercially supplied kit for verification of specifications. -If asked, renderer must provide, free of charge, sealed commercially supplied kit for checking performance. -Kit literature must specify composition of reagents sufficient to check its conformance to accepted scientific literature. -All reagents must be in ready to use liquid form. -Expiry of reagents at 2-8 ‘C must be >=6 months from date of receipt. Kit protocol |
| 59 | QUALITY CONTROL of HUMAN SERA (High Range)QUALITY CONTROL of HUMAN SERA (High Range) for clinical chemistry | Attached Literature must show target values for Glucose, Urea, Creatinine, Cholesterol, Triglycerides, Total Protein and Albumin, Ca2+, Uric acid, Total Bilirubin, Direct Bilirubin, ALT, ALP, Amylase and GGT,Na+, K+. Package literature must certify that it is made from human blood free from common infectious agents.Package literature must certify that it is made from human blood free from common infectious agents.Material must be in lyophilised form with single vial <=5 ml size on reconstitution. Pack size must be quoted against price and must be mentioned in kit literature. Band name must be quoted against price and must be mentioned in kit literature. While supplying the QC material, required cold chain must be observed Other specification As per Annaxure No.5 Item no.1 |
| 60 | QUALITY CONTROL of HUMAN-SERA (Normal Range)QUALITY CONTROL of HUMAN-SERA (Normal Range)for clinical chemistry | As per above |
| 61 | Sample cup for EM-360 transasia instrument | - |
| 62 | TOTAL PROTEIN ESTIMATION KIT ,Biuret Method, EndPoint | -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -System pack for EM 360 Biochemistry fully auto analyzer ,Reagent must with barcode and read in RF ID with compatible in EM-360 of Transasia. Reagent bottle must fit in to EM-360 reagent tray.(as per company diameter). -Supplier must set parameter in EM-360 ,when we require to established new parameter.-authorization. -Supplier attached currently valid certificate of company authorization. -Supplier attached currently valid certificate of company authorization. -With tender attach Commercial Kit insert (literature) of the brand to be supplied. -Attached Kit literature shell be considered authentic legal document for verification of specifications. -If asked, renderer must show sealed commercially supplied kit for verification of specifications. -If asked, renderer must provide, free of charge, sealed commercially supplied kit for checking performance. -Kit literature must specify composition of reagents sufficient to check its conformance to accepted scientific literature. -All reagents must be in ready to use liquid form. -Expiry of reagents at 2-8 ‘C must be >=6 months from date of receipt. Kit protocol |
| 63 | TRIGYCERIDE ESTIMATION KIT,GPO METHOD,Base on lipoprotein lipase, glycerol kinase, glycerol-3-phosphase oxidase, peroxidase EndPoint | As per above |
| 64 | UIBC ESTIMATION KIT,TIBC–IRON binding is UIBC | As per above |
| 65 | UREA ESTIMATION KIT,UREASE-GLDH METHOD ,Fixed Time Method, | As per above |
| 66 | URIC ACID ESTIMATION KIT URICASE POD method, | As per above |
| 67 | M Kit for AQUA D.I. Plant | - |
| 68 | M 53 d dialuent | Must be bar coded on reagent kit. Barcode read and Compatible with mindray 5 part cell counter (hematology analyzer) model no BC 5300 company mindray . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. |
| 69 | M 53 LH LYSE | As per above |
| 70 | M53 LH LEO 1 | As per above |
| 71 | M53 LH LEO 2 | As per above |
| 72 | M53 PROBE CLEANSER | As per above |
| 73 | M-53 Hematology human control(normal, high,& low) | As per above |
| 74 | M-53 Hematology calibrator | (1)AS per Annexure No.06 Item No. 01 (2)Supplier must provide service to calibrate the instrument when required instrument calibration. |
| 75 | ABX MINIDIL | Must be bar coded on reagent kit. Barcode read and Compatible with horiba 3 part cell counter (hematology analyzer) model no ABX micros ES 60 company horiba . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. Buffered isotonic solution for the determination of blood cell counting and the measurement of hematocrit on blood cell counter. Ready to use, for invitro diagnostic use. |
| 76 | ABX MINOCLAIR | Must be bar coded on reagent kit. Barcode read and Compatible with horiba 3 part cell counter (hematology analyzer) model no ABX micros ES 60 company horiba . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. CHEMICAL SOLUTION FOR THE CLEANING OFHORIBA BLOOD CELL COUNTERS. . Ready to use, for invitro diagnostic use. |
| 77 | ABX MINILYSEBIO | Must be bar coded on reagent kit. Barcode read and Compatible with horiba 3 part cell counter (hematology analyzer) model no ABX micros ES 60 company horiba . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. Crythrocyte lysing reagent for white blood cell counting and Hb determination on horiba blood cell counters. Ready to use |
| 78 | Abx miniclean | Must be bar coded on reagent kit. Barcode read and Compatible with horiba 3 part cell counter (hematology analyzer) model no ABX micros ES 60 5300 company horiba . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization.enzymatic slolution with proleolytic action for the cleaning of horiba medical blood cell counters ready to usefor invitro diagnostic use |
| 79 | Hematology human control(normal, high,& low) | Compatible with horiba 3 part cell counter (hematology analyzer) model no ABX micros ES 60 company horiba . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. |
| 80 | Hematology calibrator | (1) Compatible with horiba 3 part cell counter (hematology analyzer) model no ABX micros ES 60 company horiba . when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. (2)Supplier must provide service to calibrate the instrument when required instrument calibration. |
| 81 | SHEATH FOR SPINCELL 5 SERIES | Must be bar coded on reagent kit. Barcode read and Compatible with spincell 5, 5 part cell counter (hematology analyzer) model no. spincell 5 compact company spinreact. Must provide 1x RF activation card when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. Must be stable for 24 months.at 2 to 40 celcious tempareture |
| 82 | DETERGENT FOR SPINCELL 5 SERIES | As per above |
| 83 | DIALUENT FOR SPINCELL 5 SERIES | As per above |
| 84 | LYSE REAGENT FOR SPINCELL 5 SERIES | As per above |
| 85 | CLEANING SOLUTION | As per above |
| 86 | Hematology human control(normal, high,& low) | As per above |
| 87 | Hematology calibrator | (1)AS per Annexure No.08 Item No. 01 (2)Supplier must provide service to calibrate the instrument when required instrument calibration. |
| 88 | Reticulocyte reagent(vacutainer) for spincell 5 series | Compatible with spincell 5, 5 part cell counter (hematology analyzer) model no. spincell 5 compact company spinreact. when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. Must be stable for 24 months.at 15 to 30 celcious tempareture – |
| 89 | BD BACTEC STANDARD /10 AEROBIC/F CULTURE VIALS (PLASTIC) | Must be bar coded on reagent kit. Barcode read and Compatible with BD Automated blood culture instrument, model no. bactec FX 40, company BD (BACTON DICKINSON). when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. Must be stable for 24 months.at 2 to 40 celcious tempareture |
| 90 | BD BACTEC PEDS PLUS/F CULTURE VIALS (PLASTIC) | Must be bar coded on reagent kit. Barcode read and Compatible with BD Automated blood culture instrument, model no. bactec FX 40, company BD (BACTON DICKINSON). when required kit establisher in instrument supplier must be do it. Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied Supplier attached currently valid certificate of company authorization. Must be stable for 24 months.at 2 to 40 celcious tempareture |
| 91 | ACETONE POWDER | Reagents For Detection Of Acetone In Urin & Plasma Sensitivety – 10mg/100ml, AR / GR / Excellar Quality with All Assay Details. |
| 92 | Acid Phosphates estimation kit | 1-Compatible with Fully Auto + Semi Auto Analysers. About 25-50 ml preferable Pack size. 2 - Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied.2 - Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied. 3-Supplier attached currently valid certificate of company authorization. 3-Supplier attached currently valid certificate of company authorization. 4-With tender attach Commercial Kit insert (literature) of the brand to be supplied. 5-Attached Kit literature shell be considered authentic legal document for verification of specifications. 6-If asked, renderer must show sealed commercially supplied kit for verification of specifications. 7-If asked, renderer must provide, free of charge, sealed commercially supplied kit for checking performance. 8-Kit literature must specify composition of reagents sufficient to check its conformance to accepted scientific literature. 9-All reagents must be in ready to use liquid form and stable up to expiry. 10-Expiry of reagents at 2-8 ‘C must be >=6 months from date of receipt. 11-Kit protocol mentioned in kit literature must be configurable for use with fully automated/ semi automated chemistry analysers available in (Clinical Biochemistry) Laboratory, without need for manual mixing of reagents and without change in reagent and sample proportions. 12-Band name must be quoted against price and must be mentioned in kit literature. 13-Performance data must be available in kit literature and must meet international criteria for satisfactory performance and sufficient to prevent need for local validation of method. 14-Data on common interferences must be mentioned in the kit literature in sufficient details to prevent need for local validation of method. 15-While supplying the kit, required cold chain must be observed |
| 93 | Alanine Transaminase kit (SGPT/ALT), | Other specification As per above,,Method – Modified IFCC UV kinetic,Linearity ,u/l,Precise sensitivity- 4 u/l,Incubation time 1 (delay)+2 or 3 Min at 37,Precise sensitivity- 0.3 gm/dl |
| 94 | ALBUMINE estimation kit | Linearity up to 6 gm/dl,Method – BCG,Other specification As per Above |
| 95 | Alkanie Phosphatase kit | Precise sensitivity- 5 iu/l,Method – IFCC, ,Linearity up to 700 u/l,Precise sensitivity- 2 u/l, Other specificationAs per above |
| 96 | Amylase estimation kit | Linearity ,Method-*CNPG3-(Glucose Oligosaccharide) kinetic ,Other specification As per above |
| 97 | Aspirate Transaminase kit (SGOT / AST ) Method –Modified IFCC UV kinetic Linearity u/l Precise sensitivity- 2 u/l Incubation time 1 (delay)+2 or 3 Min at 37 | Other specification As per above,,Method – Modified IFCC UV kinetic,Linearity ,u/l,Precise sensitivity- 4 u/l,Incubation time 1 (delay)+2 or 3 Min at 37,Precise sensitivity- 0.3 gm/dl |
| 98 | Bilirubin Direct and Total Single Reagent estimation kit Method – Jendrassik method Linearity up to 25 mg/dl Precise sensitivity- 0.10 mg/dl | Other specification As perabove |
| 99 | Bilirubin Direct and Total Single Reagent estimation kit Method – Modified Bergh & Muller Method Single (MONO) Reagent for Total bilirubin estimation and Single (MONO) Reagent for Direct bilirubin estimation Linearity 20 mg/dl Precise sensitivity- 0.10 mg/dl Reagent use without need for manual mixing of reagents and without change in reagent and sample proportions. | Other specification As perabove |
| 100 | Calcium kit estimation kit Method Arsenazo III Mono vial reagent pack Linearity up to 15 mg/dl Precise sensitivity- 1 mg/dl Incubation time 1 to 2 Min at 20 to 37 | Other specification As perabove |
| 101 | Cholesterol (Total) Kit Method – CHOD-PAP enzymatic End Point Linearity 700 mg/dl Precise sensitivity-3 mg/dl Incubation time 5 Min at 37 | Other specification As perabove |
| 102 | Cholinesterase kit Linearity u/l Precise sensitivity- 0.04 kU/LPrecise sensitivity- 0.04 kU/LPrecise sensitivity- 0.04 kU/LPrecise sensitivity- 0.04 kU/LPrecise sensitivity- 0.04 kU/L Liquid Stable Reagents Enzymatic - Kinetic Method. DTNB , Butyryl thiocholine substrate Linearity > 6000 U / L Compatible with Miura & Metrolab Fully Auto + Semi Auto Analysers. About 50 ml. Packs. | Other specification As perabove |
| 103 | CK-MB Kit Method – IFCC UV kinetic (DGKC ) Linearity up to 1000 u/l Precise sensitivity- 2 u/l Incubation time 5 (delay)+ 5 Min at 37centigrade or 10 min RT | Other specification As perabove |
| 104 | CK-NAC Method – IFCC UV kinetic (DGKC ) Linearity up to 1000 u/l Precise sensitivity- 1 u/l Incubation time 3/5 (delay)+ 5 Min at 37centigrade | Other specification As perabove |
| 105 | Control (Human) for ISE electrolyte NA,K,Cl | As per Above |
| 106 | CONTROL (Human)- Quality control human sera for clinical chemistry (High Range) | 1) Attached Literature must show target values for Glucose, Urea, Creatinine, Cholesterol, Triglycerides, Total Protein and Albumin, Ca2+, Uric acid, Total Bilirubin, Direct Bilirubin, ALT, ALP, Amylase and GGT,Na+, K+. Package literature must certify that it is made from human blood free from common infectious agents. Material must be in lyophilised form with single vial <=5 ml size on reconstitution. Pack size must be quoted against price and must be mentioned in kit literature. Band name must be quoted against price and must be mentioned in kit literature. While supplying the QC material, required cold chain must be observed 2) Other specification As per Annaxure No.10 Item no.2 |
| 107 | CONTROL (Human)- Quality control human sera for clinical chemistry (Normal Range) | as per above |
| 108 | Control (Human) of Ferrittin | as per above |
| 109 | Control (Human) of T3 | as per above |
| 110 | Control (Human) of T4 | as per above |
| 111 | Control (Human) of TSH | as per above |
| 112 | CREATININE Kit Single Reagent Kit , Not required to mix Method – JAFFE modified enzymatic fix time kinetic Method – JAFFE modified enzymatic fix time kinetic Linearity 25 mg/dl Precise sensitivity-1 mg/dl No interference with Bilirubin up to 6 mg/dl | 1-Compatible with Fully Auto + Semi Auto Analysers. About 25-50 ml preferable Pack size. 2 - Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied.2 - Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied. 3-Supplier attached currently valid certificate of company authorization. 3-Supplier attached currently valid certificate of company authorization. 4-With tender attach Commercial Kit insert (literature) of the brand to be supplied. 5-Attached Kit literature shell be considered authentic legal document for verification of specifications. 6-If asked, renderer must show sealed commercially supplied kit for verification of specifications. 7-If asked, renderer must provide, free of charge, sealed commercially supplied kit for checking performance. 8-Kit literature must specify composition of reagents sufficient to check its conformance to accepted scientific literature. 9-All reagents must be in ready to use liquid form and stable up to expiry. 10-Expiry of reagents at 2-8 ‘C must be >=6 months from date of receipt. 11-Kit protocol mentioned in kit literature must be configurable for use with fully automated/ semi automated chemistry analysers available in (Clinical Biochemistry) Laboratory, without need for manual mixing of reagents and without change in reagent and sample proportions. 12-Band name must be quoted against price and must be mentioned in kit literature. 13-Performance data must be available in kit literature and must meet international criteria for satisfactory performance and sufficient to prevent need for local validation of method. 14-Data on common interferences must be mentioned in the kit literature in sufficient details to prevent need for local validation of method. 15-While supplying the kit, required cold chain must be observed |
| 113 | CREATININE Kit Method – JAFFE enzymatic fix time kinetic Method – JAFFE enzymatic fix time kinetic Single (MONO) Reagent for estimation , and ready to use. Reagent use without need for manual mixing of reagents and without change in reagent and sample proportions.Reagent use without need for manual mixing of reagents and without change in reagent and sample proportions. Linearity 25 mg/dl Precise sensitivity-1 mg/dl No interference with Bilirubin up to 6 mg/dl | Other specification As perabove |
| 114 | De-ionized Water With Conductivity less than 1 micro seamens with centicuner. NCCLS type ii or better | Other specification As perabove |
| 115 | Direct LDL cholesterol kit With calibrator. Method – Direct method Linearity 650 iu/ l Precise sensitivity - 2 mg/dl | Other specification As perabove |
| 116 | Ditrect HDL cholesterol Method – Direct Method Linearity Precise sensitivity- 10 mg/dl l Incubation time & read time in 3 Min. | Other specification As perabove |
| 117 | Elisa for Vitamin B12 Method – Elisa Analytical Sensitivity: 70.13 pg/mL at 2SD Accuracy: correlation coefficient 0.9506 with a reference method | 1) 1) Intra-assay Precision: CV = 6.% Inter-assay Precision: CV = 10% Pre-coated 96 micro-well plate Standard With Calibrator as per required in assay Assay Diluent concentrate Stabilizing Agent Enzyme Reagent,Biotin Reagent Neutralizing Buffer,Releasing Agent Wash Buffer ( Concentrate),TMB Substrate,Stop Solution,Adhesive Plate Covers 2) Other specification As per Annaxure No.10 Item no.2 |
| 118 | Elisa for Vitmin D Method – ELISA Analytical Sensitivity: 1.140 ng/mL at 2SD | 1) Other specification As per Above |
| 119 | Elisa kit for Ferrittin Method – ELISA Sensitivity: Detects ferritin levels as low as 0.06 ng/mL at 2SD Accuracy: r= 0.997 against reference ELISA by an external lab | 1) Other specification As per Above |
| 120 | Elisa kit for Thyroid gland stimulation hormone Method-Elisa Linearity Precise sensitivity 4 pg/mLPrecise sensitivity 4 pg/mL Sensitivity: Detects TSH levels as low as0.035µIU/mL Specificity: No cross reactivity detected with related hormones: FSH, LH and hCG Linearity: 1:128 dilution on 36 IIU/mL sample | 1) Other specification As per Above |
| 121 | Elisa kit for Free Thyroid gland Tri- iodothypomine.Elisa kit for Free Thyroid gland Tri- iodothypomine. Method – ELISA Sensitivity: 0.98 pg/mL Accuracy: r=0.91 | 1) Other specification As per Above |
| 122 | Elisa kit for Free Thyroid gland Tetra-iodothypomineElisa kit for Free Thyroid gland Tetra-iodothypomine Method – Elisa Sensitivity: 0.20ng/mL Accuracy: r=0.94 | 1) Other specification As per Above |
| 123 | Elisa kit for Thyroid gland Tri- iodothypomine.Elisa kit for Thyroid gland Tri- iodothypomine. Method – ELISA Analytical Sensitivity: 173 ng/mL at 2-SD Accuracy: correlation coefficient 0.99 with a reference method | 1) Other specification As per Above |
| 124 | Elisa kit for Thyroid gland Tetra-iodothypomine Method ELISA Analytical Sensitivity:Â 176 µg/dL at 2-SD Accuracy:Â correlation coefficient 0.98 with a reference method | 1) Other specification As per Annaxure No.10 Item no.27-(1) and (2) |
| 125 | Ferrittin single (mono) Test Method – Latex Immuno Turbidometry Linearity ug/l Precise sensitivity- 5 u/l | 1) Compatible with semiauto analyser for Transasia chem-7 ,Microlab,Robonic and Fully auto analyser EM-360.base 2) Other specification As per above Item no.2 |
| 126 | Flow cell clean solution | 1)Compatible with semiauto analyser for Transasia chem-7 ,Microlab,Robonic 2) Other specification As per Above |
| 127 | Fouchet’s reagent | AR / GR / Excellar Quality with All Assay Details. Other specification As per Above |
| 128 | Glucose kit Method – GOD-PAP enzymatic Linearity 600 mg/dl Incubation time 10- Min at 37 or 15 min at RT | 1-Compatible with Fully Auto + Semi Auto Analysers. About 25-50 ml preferable Pack size. 2 - Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied.2 - Attach currently latest valid ISO 13485 certificate for the place of manufacture of brand to be supplied. 3-Supplier attached currently valid certificate of company authorization. 3-Supplier attached currently valid certificate of company authorization. 4-With tender attach Commercial Kit insert (literature) of the brand to be supplied. 5-Attached Kit literature shell be considered authentic legal document for verification of specifications. 6-If asked, renderer must show sealed commercially supplied kit for verification of specifications. 7-If asked, renderer must provide, free of charge, sealed commercially supplied kit for checking performance. 8-Kit literature must specify composition of reagents sufficient to check its conformance to accepted scientific literature. 9-All reagents must be in ready to use liquid form and stable up to expiry. 10-Expiry of reagents at 2-8 ‘C must be >=6 months from date of receipt. 11-Kit protocol mentioned in kit literature must be configurable for use with fully automated/ semi automated chemistry analysers available in (Clinical Biochemistry) Laboratory, without need for manual mixing of reagents and without change in reagent and sample proportions. 12-Band name must be quoted against price and must be mentioned in kit literature. 13-Performance data must be available in kit literature and must meet international criteria for satisfactory performance and sufficient to prevent need for local validation of method. 14-Data on common interferences must be mentioned in the kit literature in sufficient details to prevent need for local validation of method. 15-While supplying the kit, required cold chain must be observed |
| 129 | Hemocysteine estimation kits Method – Enzymatic cycling fix time kinetic method Linearity Method – Enzymatic cycling fix time kinetic method Linearity µmol/L. µmol/L. Precise sensitivity:- 1 µmol/L.Precise sensitivity:- 1 µmol/L. Reagents. R1, R2, R3. Enzymatic UV Kinetic 340 nm Method. Calibrators must be supplied with Kit having reconsituted open bottle stability of 30 days. | as per above |
| 130 | LDH Kits Method – IFCC Linearity u/l Precise sensitivity- 10 iu/l Incubation time 1 (delay)+2 or 3 Min at 37 | as per above |
| 131 | Lipase kit With calibrator. Method – Methyl Resorufin fix time Linearity 250 iu/ l Incubation time 1 (delay)+1 Min. read tim at 37 | As per above |
| 132 | Multi Calibrator (HUMAN) | 1) Attached Literature must show calibration values for Glucose, Urea, Creatinine, Cholesterol, Triglycerides, Total Protein and Albumin, Ca2+, Uric acid, Total Bilirubin, Direct Bilirubin, ALT, ALP, Amylase and GGT,Na+,K+. Attached Literature must show that, wherever applicable, calibration values are traceable to accepted international primary reference materials. Package literature must certify that it is made from human blood free from common infectious agents. Calibrator must be in lyophilised form with single vial <=5 ml size on reconstitution. Pack size must be quoted against price and must be mentioned in kit literature. Band name must be quoted against price and must be mentioned in kit literature. While supplying the calibrator, required cold chain must be observed 2) Other specification As per Annaxure No.10Item no.2 |
| 133 | Natural detergent for lab-ware | 1) Neutral Ph, Lab Ware Washing Solution 2) Other specification As per Annaxure No.10 Item no.2 |
| 134 | Rothras powder | AR / GR / Excellar Quality with All Assay Details. |
| 135 | ketonbody detection | Other specification As per Annaxure No.10 Item no.2 |
| 136 | TOTAL PROTEIN Method – BIURET- End PointMethod – BIURET- End Point Linearity up to 12 gm/dl Precise sensitivity -0.6 gm/dl | 1) Attached Literature must show calibration values for Glucose, Urea, Creatinine, Cholesterol, Triglycerides, Total Protein and Albumin, Ca2+, Uric acid, Total Bilirubin, Direct Bilirubin, ALT, ALP, Amylase and GGT,Na+,K+. Attached Literature must show that, wherever applicable, calibration values are traceable to accepted international primary reference materials. Package literature must certify that it is made from human blood free from common infectious agents. Calibrator must be in lyophilised form with single vial <=5 ml size on reconstitution. Pack size must be quoted against price and must be mentioned in kit literature. Band name must be quoted against price and must be mentioned in kit literature. While supplying the calibrator, required cold chain must be observed 2) Other specification As per Annaxure No.10Item no.2 |
| 137 | Triglyceride Kit Method –GOD-POD Enzymatic, based on lipoprotein lipase, glycerol kinase, glycerol-3-phosphase oxidase, peroxidase End-Point Method –GOD-POD Enzymatic, based on lipoprotein lipase, glycerol kinase, glycerol-3-phosphase oxidase, peroxidase End-Point Linearity 1000 mg/dl Precise sensitivity 5 mg/dl Incubation time 5- Min at 37 or 15 min at RT or 15 min at RT | as per above |
| 138 | TROPONIN I card | as per above |
| 139 | UREA-GLDH Kit Method –GLDH UV enzymatic fix time kinetic Method –GLDH UV enzymatic fix time kinetic Linearity 300 mg/dl Precise sensitivity-2 mg/dl Incubation time 30 second (delay) +1 Min at 37 | as per above |
| 140 | URIC ACID Kit Method – URICASE-POD Linearity mg/dl Precise sensitivity- 2 mg/dl Incubation time 5 Min at 37 or 10 Min on RT | as per above |
| 141 | Uristrips for glucose & Albumine | 1) Urinalysis Reagent Strip is a fast, qualitative and semi-quantitative, dip-and-read test for the detection of Glucose, Albumine,It is intended for in vitro diagnostic use only. Test results are interpreted by direct comparison to the color blocks printed on the canister label.acid), 2) Other specification As per Annaxure No.10 Item no.2 1) Reagent Strips Or Urin Analysis Reagent Strips Disposble Plastic Strips With Attached Reagent Area For Urinary Glucose & Ketones |
| 142 | Uristrips for glucose & Ketone bodies | Urinalysis Reagent Strip is a fast, qualitative and semi-quantitative, dip-and-read test for the detection of Glucose, , Ketone (Acetoacetic acid),Ketone (Acetoacetic ,It is intended for in vitro diagnostic use only. Test results are interpreted by direct comparison to the color blocks printed on the canister label.acid), 2) Other specification As per Annaxure No.10 Item no.2 |
| 143 | ANTI SERA - H | Ready To Use Stable Reagents Lectin Ulex Europafus Lectin For Slide And Tube Tests. Ready To Use For Recognisation H Antogen For Human Red Cells Specificity 100% |
| 144 | ANTI A1 GROUPING SERA | READY TO USE STABLE REAGENTS ANTI A1 LECTIN DOUCHOS BIFLORUS LECTIN FOR SLIDE AND TUBE TESTS READY TO USE CALLIBRATATE TO DEFFERENTIATE MOST A1 RED CELLS FROM A2 RED CELLS SPECIFICITY 100% |
| 145 | ANTI AB | READY TO USE FOR INVITRO DETECTION AND IDENTIFICATION OF HUMAN ABO GROUP BY DIRECT AGGLUTINATION SPECIFICITY 100% |
| 146 | Anti sera –A 10 ml IgG & IgM | Monoclonal Blood Grouping Antibodies For Slide & Tube Test Igg + Igm 100 % Sensitive & 100 Specific Titer With Known Cell Should Be 256 |
| 147 | BOVINE ALBUMIN | 22% SOLUTION IN VITRO DETECTION OF INCOMPLETE ANTIBODY |
| 148 | COOMBS SERA(ANTI HUMAN GLOBULIN) | ANTI HUMAN SERUM POLY SPECIFIC SERUM IN VITRO DIAGNOSTIC SERUM FOR PERFOMING DIRECT & INDIRECT ANTIGLOBULIN TEST |
| 149 | Copper sulphate powder | 100 Gm |
| 150 | Forhead Thermometer | - |
| 151 | Glucose powder | Dehydrated Powder |
| 152 | Glucose powder 200gm | 1 Nos. |
| 153 | High sensitivity Thermal Paper Rolls | for Robonic elisa redear |
| 154 | High sensitivity Thermal Paper Rolls | for Microlab Elisa reader |
| 155 | High sensitivity Thermal Paper Rolls | for Microlab Elisa reader |
| 156 | High sensitivity Thermal Paper Rolls | for Microlab Elisa reader |
| 157 | High sensitivity Thermal Paper Rolls | for Chem 7 trangesasia Semi Auto Analyserr |
| 158 | High sensitivity Thermal Paper Rolls | for Robonic Elisa redear |
| 159 | High sensitivity Thermal Paper Rolls | for Chem 7 trangesasia Semi Auto Analyserr |
| 160 | High sensitivity Thermal Paper Rolls | for Robonic Elisa redear |
| 161 | HIV ELISA 4TH GENERATION | ENZYME IMMUNOASSAY FOR THE QUALITATIVE DETERMINATION HIV P24 AG & ANTIBODY TO HIV TYPE-I AND HIV TYPE II IN SERUM OR PLASMA 4TH GENERATION SENSITIVITY 100% SPECIFIC MORE THAN 99.5% WITH INTERNAL CONTROLS |
| 162 | HIV RAPID KIT 4TH GENERATION | READY TO USE STABLE REAGENT 4TH GENERATION IMMUNCHROMATOGRAPHY ASSAY SOLID PHASE COATED HIV 1 & HIV 2 RECOMBINANT AND SYNTHETIC PEPTIDE ANTIGEN AND ANTIBODY TO HIV 1 P24 IN SERUM OR PLASMA WITH INTERNAL CONTROLS SPECIFICITY – MORE THAN OR EQUAL TO 99% SENSITIVITY 100% |
| 163 | Micropore Tape | Size: 1 " |
| 164 | Micropore Tape | Size: 1.5 " |
| 165 | Micropore Tape | Size: 2 " |
| 166 | Normal saline | Use Of Laboratory Testing |
| 167 | Single Blood Bag CPDA | Â 350 ml Must provide sterility certificate |
| 168 | Temp. Chart for Blood Bank refrigeratore Pempol | - |
| 169 | Thermal Printer Roll 110 mm | aluminium |
| 170 | Thermal Printer Roll 110 mm | aluminium |
| 171 | Tourniquet belt | - |
| 172 | Tourniquit Bag With Cuff All Size | standard |
| 173 | Tourniquit Bag With Cuff All Size | standard |
| 174 | Anti B Blood Gr.Serum (Monoclonal) | Unit of 5 ml bulb |
| 175 | 0.1 N HCL | READY TO USE FOR HEMOGLOBIN ESTIMATION BY SAHLIS METHOD STABLE AR/GR/SXCELLAR QUALITY WITH ALL ASSAY DETAILS |
| 176 | A.P.T.T. | READY TO USE STABLE REAGENTS METHOD – MECHANICAL/MANUAL CLOT DETECTION SYSTEMS DIAGNOS APTT REAGENT CALCIUM CHLORIDE (0.02 MOL/L) TSC SOLUTION |
| 177 | A.P.T.T. | Suitable For Fourclot Co-Agulation Analyzer With Internal Control |
| 178 | Acetone | Liquid |
| 179 | ACETONE POWDER | REAGENTS FOR DETECTION OF ACETONE IN URIN & PLASMA SENSITIVETY – 10MG/100ML |
| 180 | Anti A Blood Grouping Serum (Monoclonal) | Unit of 5 ml bulb |
| 181 | Anti RH (D) Serum Human | Unit of 5 ml bulb |
| 182 | Barium chloride powder | 10% SOLUTION AR/GR/EXCELLAR QUALITY WITH ALL ASSAY DETAILS |
| 183 | BARIUM CLORIDE SOLUTION | 10% SOLUTION AR/GR/EXCELLAR QUALITY WITH ALL ASSAY DETAILS |
| 184 | Basic fuschin powder | Dehydrated Powder |
| 185 | Blood Collection Tube EDTA Vaccute | collection tube with (K2/K3 EDTA) K2/K3 EDTA. volume 4-5 ml |
| 186 | Blood Collection Tube EDTA K2 Non Vaccute | collection tube with (K2/K3 EDTA) K2 EDTA. volume 4-5 ml |
| 187 | Blood Collection Tube EDTA K3 Non Vaccute | collection tube with (K2/K3 EDTA) K3 EDTA. volume 4-5 ml |
| 188 | Capillary box | standard |
| 189 | Capillary box | standard |
| 190 | CIDAR WOOD OIL | READY TO USE STABLE, ANALYTICAL REAGENT FOR MICROSCOPY |
| 191 | - | AR/GR/SXCELLAR QUALITY WITH ALL ASSAY DETAILS |
| 192 | Citrate blood collection Tube | tubes for collection of blood for APTT estimation. Required quantity of citrate must be added. Total volume of blood draw 2 ml. |
| 193 | Concentrated HCl | 100% Concentrated |
| 194 | Control for DRABKIN’S solution 10 ml | - |
| 195 | Coplin jar | standard |
| 196 | Coverslip Glass | 22 X 22 mm 10 Gms |
| 197 | Coverslip Long Glass | 22 X 50 mm |
| 198 | DPX bottle | standard |
| 199 | DPX bottle | standard |
| 200 | DRABKINS REAGENT | FOR HEMOGLOBIN ESTIMATION READY TO USE WITH STANDARD FOR CYNMEATHHEMOGLOBIN METHOD |
| 201 | ESR Stand | standard |
| 202 | ESR tube Disposable | Disposable with marking pack 100 tube |
| 203 | ESR TUBE Glass | gratuated |
| 204 | ESR TUBE Glass | gratuated |
| 205 | Falcipaum detection Kit - pHRP antigen - for detection Falciparum | - |
| 206 | FIELD STAIN A | READY TO USE PERIPHERAL STAIN |
| 207 | FIELD STAIN B | READY TO USE PERIPHERAL STAIN |
| 208 | Filer paper (whatsman) | - |
| 209 | FOUCHETS REAGENT | REAGENTS FOR THE DETCTION OF THE BILE PIGMENT IN URINE BY FOUCHETS TECHNIQUE. DIAGNOSTIK REAGENTS |
| 210 | Glass Rode | - |
| 211 | Glass Rode | - |
| 212 | Glass Slide | standard |
| 213 | HB Pipette 20 mm | - |
| 214 | HB Pipette 20 mm | - |
| 215 | Hb square Tube | sahlis |
| 216 | HB Square Tube | - |
| 217 | Hemoglobin pipette | sahlis |
| 218 | Hemoglobin pipette | sahlis |
| 219 | Hemoglobin tube | sahlis square tube |
| 220 | Hemoglobin tube | sahlis square tube |
| 221 | Hydrochloric Acid 35 % pure | AR / GR / Excellar Quality with All Assay Details. |
| 222 | KETO STRIP | REAGENT STRIPS FOR URIN ANALYSIS REAGENT STRIPS DISPOSBLE PLASTIC STRIPS WITH ATTACHED REAGENT AREA FOR URINARY GLUCOSE & KETONES |
| 223 | MALARIA CARD TEST | FOR THE DETECTION OF P.VIVAX AND P.FALCIPARUM ANTIGEN DETECTION KIT BASED ON THE PRINCIPLE OF CHROMATOGRAPHY. |
| 224 | METHANOL | READY TO USE LABORATORY REAGENT |
| 225 | Microscope lamp | suitable for all microscope |
| 226 | Microscope lamp | suitable for all microscope |
| 227 | NaCl powder | Dehydrated Powder |
| 228 | Natural detergent for lab-ware | Neutral Ph, Lab Ware Washing Solution |
| 229 | P.C.V. Tube | standard |
| 230 | P.C.V. Tube | standard |
| 231 | POTASSIUM DIOXALATE POWDER | Di. Potassium Oxakate Monohydrate K2c2o4 * H2o >= 98.5% Molecular Weight – 184.24 Gm/Mol Heavy Metals <= 0.005% (As Pb) |
| 232 | Ppottasium dichromate powder | Dehydrated Powder READY TO USE STABLE REAGENT METHOD – MECHANICAL CLOT DETECTION SYSTEMS DIAGNOS THROMBO REAGNET TSC SOLUTION (3.2%) |
| 233 | PT | - |
| 234 | PT | Suitable For Fourclot Co-Agulation Analyzer With Internal Control |
| 235 | RAPID H & E STAIN | Reagents Stable And Ready To Use Rapid H & E Stain With H & E Nueclear Stain, Eosin, Propanol, Xylene, Dpx Mountant, Wash Buffer |
| 236 | Reagent Strips for estimating Albumin & Glucose in Urine | URINE ANALYSIS STRIP FOR FAST QUALITATIVE AND SEMI QUANTITATIVE,DIP AND READ TEST FOR THE DETECTION OF GLUCOSE, ALBUMIN. |
| 237 | RETICULOCYTE STAIN | Reagent Stable Ready To Use Brilliant Cresyl Blue Reagent Ar/Gr Grade/Excellar Quality With All Assay Details |
| 238 | Slide cleaning Solution | - |
| 239 | Slide cleaning Solution | - |
| 240 | Slide storage wooden box | Neutral PH |
| 241 | Slide storage wooden box | Neutral PH |
| 242 | SODIUM CITRATE SOLUTION | SODIUM CITRATE 3.8% W/V FOR ESR ESTIMATION AR/GR GRADE/EXCELLAR QUALITY WITH ALL ASSAY DETAILS |
| 243 | Stain - Malarial parasite staining kit | - |
| 244 | Urine Collection Bag | - |
| 245 | Urine container | - |
| 246 | Urine container Disposible | plastic, Reuseble, Non sterile |
| 247 | Urine Port Plastic | plastic |
| 248 | URISTRIP FOR 10 PARAMETER | 10 PARAMETER URINANALYSIS REAGENT STRIP, QUALITATIVE AND SEMI QUANTITATIVE, DIP AND READ TEST FOR THE DETECTION OF GLUCOSE,BILIRUBIN,KETONE,SPECIFIC GRAVITY,BLOOD,Ph,PROTEIN,UROBILINOGEN,NITRITEAND LEUCOCYTES IN URINE, FOR INVITRO DIAGNOSTIC USE |
| 249 | XYLENE | Ar/Gr Grade/Excellar Quality With All Assay Details |
| 250 | Kit for Detection of HIV I & II Antibodies in Human Sera/plasma-Simple Test method | 1 test unit |
| 251 | Agar agar powder | Dehydrated Powder |
| 252 | Albert stain A | 100Ml Bottle |
| 253 | Albert stain A | 100Ml Bottle |
| 254 | Antibiotic Disc - Amoxycillin + clavulinic acid (30=20 /10 micrograms) | - |
| 255 | Antibiotic Disc - Cefaclor (30 micrograms ) | - |
| 256 | Antibiotic Disc - cefepime (30 micrograms ) | - |
| 257 | Antibiotic Disc - cefexime (5 micrograms ) | - |
| 258 | Antibiotic Disc - Cefoxitin(30 micrograms) | - |
| 259 | Antibiotic Disc - Chloramphenicol (30 micrograms) | - |
| 260 | Antibiotic Disc - lmipenem (10 microgram) | - |
| 261 | Antibiotic Disc - Ofloxacin (5 microgram) | - |
| 262 | Antibiotic Disc - penicillin G (10 units) | - |
| 263 | Antibiotic Disc - piperacillin ( 100 micrograms) | - |
| 264 | Antibiotic Disc - piperacillin + Tazobactum (100/10 micrograms ) | - |
| 265 | Antibiotic disc - tcarcillin + clavulanic acid (75/10 micrograms ) | - |
| 266 | Antibiotic Disc - Ticarcillin (75 micrograms ) | - |
| 267 | Antibiotic Disc - Vancomycin (30 m icrograms) | - |
| 268 | Antibiotic Disc amoxycillin 20 mcg and clavulanic acid 10mcg | - |
| 269 | Antibiotic Disc- Azithromicin (15 m crograms ) | - |
| 270 | Antibiotic Disc -Aztreonam 30 mocrograms | - |
| 271 | Antibiotic Disc- Cefeperazone +sulbactam (75/10 micrograms ) | - |
| 272 | Antibiotic Disc -cefepime + Tazobactum (30/10 micrograms ) | - |
| 273 | Antibiotic Disc -cefoperazone (75micrograms ) | - |
| 274 | Antibiotic Disc cefotaxime30 mcg & cefotaxime clavulanic acid 30/10mcg | - |
| 275 | Antibiotic Disc -Cefpodoxime (10 micgrams ) | - |
| 276 | Antibiotic Disc -Ceftazidime (30 micrograms ) | - |
| 277 | Antibiotic Disc -Ceftazimide +clavula acid (30/10 micrograms ) | - |
| 278 | Antibiotic Disc -Ceftizoxime (30 micrograms ) | - |
| 279 | Antibiotic Disc- ceftriaxone (30 micrograms ) | - |
| 280 | Antibiotic Disc -ceftriaxone + sulbactam (30/15 micrograms ) | - |
| 281 | Antibiotic Disc -Ceftriaxone +Tazobactum (30/10 micrograms ) | - |
| 282 | Antibiotic Disc- Meropenem (10 microgram) | - |
| 283 | Antibiotic Disc -Norfloxacin (10 microgram) | - |
| 284 | Antibiotic Disc piperacillin & tazobactum disc (100mcg/10mcg) | - |
| 285 | Antibiotic Disc- polymixin B (300 Units ) | - |
| 286 | Antibiotic Disc_Tobramycin (10 micrograms | - |
| 287 | Antibiotic Disc-Amikacin(30 micrograms) | - |
| 288 | Antibiotic Disc-Amoxycillin (5 micrograms) | - |
| 289 | Antibiotic Disc-Ampicillin (10 micrograms ) | - |
| 290 | Antibiotic Disc-Ampicillin + sulbacium (10/10 micrograms ) | - |
| 291 | Antibiotic Disc-Cefotaxime (30 micrograms) | - |
| 292 | Antibiotic Disc-Cefuroxime (30 micrograms) | - |
| 293 | Antibiotic Disc-Cephalexin (30 micrograms) | - |
| 294 | Antibiotic Disc-Ciprofloxacin (5 microgram) | - |
| 295 | Antibiotic Disc-Clindam ycin (2 micrograms) | - |
| 296 | Antibiotic Disc-Cotrimexazole ( micrograms) | - |
| 297 | Antibiotic Disc-Cotrimexazole ( micrograms) | - |
| 298 | Antibiotic Disc-Cotrimexazole ( micrograms) | - |
| 299 | Antibiotic Disc-Doxycyline (30 microgram) | - |
| 300 | Antibiotic Disc-Erythromycin (15 microgram) | - |
| 301 | Antibiotic Disc-Gentamicin (10 microgram) | - |
| 302 | Antibiotic Disc-Levofloxacin (5microgram) | - |
| 303 | Antibiotic Disc-Linezolid (30 microgram) | - |
| 304 | Antibiotic Disc-Nilidixic Acid ( micrograms) | - |
| 305 | Antibiotic Disc-Nilidixic Acid ( micrograms) | - |
| 306 | Antibiotic Disc-Nilidixic Acid ( micrograms) | - |
| 307 | Antibiotic Disc-Nitrofuraintoin ( micrograms) | - |
| 308 | Antibiotic Disc-Nitrofuraintoin ( micrograms) | - |
| 309 | Antibiotic Disc-Nitrofuraintoin ( micrograms) | - |
| 310 | Antibiotic Disc-Tetracycline (30 micrograms) | - |
| 311 | Antibiotic Disc-Tiecoplanin (30 micrograms) | - |
| 312 | Antibiotic ring for gram negative organism | Multiple Antibiotic Disc Ring For Gram Negative Bacteria |
| 313 | Antibiotic ring for gram positive organism | Multiple Antibiotic Disc Ring For Gram Positive Bacteria |
| 314 | Antibiotic ring for urinary organism | Multiple Antibiotic Disc Ring For Urinary Bacteria |
| 315 | Antibiotic tetracycline disc | Strength 10Mcg |
| 316 | Antisera-Salmonella 02 antiserum | - |
| 317 | Antisera-satmoneila 04 Antiserum | - |
| 318 | Antisera-satmoneila 09Antiserum | - |
| 319 | Arobic Culture Vials Adult | - |
| 320 | Arobic Culture Vials Pediatric | - |
| 321 | ASO | LATEX AGGLUTINATION METHOD FOR THE QUALITATIVE AND SEMI-QUANTITATIVE DETERMINATION OF ASO IN SERUM,WITH INTERNAL CONTROLS,HIGHLY,STABLE REAGENTS SENSITIVE AND HIGHLY SPECIFIC |
| 322 | Autoclavable bottle for culure | 20 ml capacity borosilated glass with screw caped |
| 323 | Autoclavable bottle for culure | 50 ml capacity borosilated glass with screw caped |
| 324 | Autoclavable bottle for culure | 100 ml capacity borosilated glass with screw caped |
| 325 | Autoclavable bottle for culure | 20 ml capacity borosilated glass with screw caped |
| 326 | Autoclavable bottle for culure | 50 ml capacity borosilated glass with screw caped |
| 327 | Autoclavable bottle for culure | 100 ml capacity borosilated glass with screw caped |
| 328 | Autoclavable bottle for media preparation | 1 litre capacity borosilated glass |
| 329 | Autoclavable bottle for media preparation | 1 litre capacity borosilated glass |
| 330 | Autoclave label | - |
| 331 | Autoclave label | - |
| 332 | Bile esculine agar | Ready To Use Powder |
| 333 | Blood Collection Tube Plain Non Vaccute | For Serum. With clot activator. Total volume of blood draw 4 ml. |
| 334 | Blood Collection Tube Plain Vaccute | For Serum. With clot activator. Total volume of blood draw 4 ml. |
| 335 | Chiller Rack (96 Hole) | - |
| 336 | Concentrated H2SO4 | 100% Concentrated |
| 337 | Controls for chikungunya ELISA | Positive And Negative Controls |
| 338 | Controls for dengue IgM ELISA | Positive And Negative Controls |
| 339 | Controls for dengue NS1 ELISA | Positive And Negative Controls |
| 340 | Controls for hepatitis A IgM ELISA | Positive And Negative Controls |
| 341 | Controls for hepatitis E IgM ELISA | Positive And Negative Controls |
| 342 | Controls for measles IgM ELISA | Positive And Negative Controls |
| 343 | Cooked meat pieces | Bullock Heart Muscle Pieces |
| 344 | CRP | QUANTITATIVE LATEX ENHANCED IMMUNOTURBIDIMETRIC TEST FOR THE QUANTITATIVE MEASURMENT OF CRP IN HUMAN SERUM OR PLASMA HIGHLY SENSITIVE AND HIGHLY SPECIFIC STABLE REAGENTS WITH CALIBRATOR |
| 345 | CRP | > LATEX SLIDE TEST FOR DETERMINATION OF CRP IN SERUM WITH INTERNAL CONTROL STABLE REAGENTS HIGHLY SPECIFIC AND WITH HIGH SENSITIVITY |
| 346 | Disposable petri dish (100 mm) | - |
| 347 | Disposable petri dish (110 mm) | - |
| 348 | Disposable petri dish (110 mm) | - |
| 349 | Disposable petri dish (90 mm) | - |
| 350 | Disposable sterile container | 60 ml capacity |