Construction Of Water Supply Scheme At Motegaon G.P- Tah- Chimur
Tender Value
77.94 Lakhs
Estimated cost
Bid Submission
07 Apr 2022
0 days left
EMD
78000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
chimur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Water Supply Scheme At Motegaon G.P- Tah- Chimur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Apr-2022 | ggd | Date | 07-Apr-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Sub work No. 1 :-SUPPLY WELL 5 M DIA & 15 M DEEP Item No.1 :- Excavation for in general in Hard material comparising of soft rock, hard rock manjra rockin wet or dry condition for head works ie. Intake well connecting main jack well pump house supply well etc. for lift 1.50 M and lead of 150 M including barricating guarding disposing off surplus excavated stuff with radius of 0.50 km as directed by engineer in charge. LIFT 12 to 13.5 M |
| 2 | LIFT 13.5 to 15 M |
| 3 | Item No.2 :- Providing & laying in situ,followinggrade of trap/ granite/ quartzite/ gneiss metalfor foundation and bedding including dewatering,form work, compacting and curing, finishing etc. complete. M-15 Grade PCC1:2:4 Lift 7.50 TO 9 FOR MISC WORK FIXING LADDER |
| 4 | Item No. 3 :- Providing and casting in situ C.C. of trap / granite / quartzite / gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer in charge including normal dewatering, plywood formwork, bully / steel prop-ups, compaction, finishing the formed surfaces with CM (1:3) of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only). Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted. (Excluding M.S. or Tor reinforcement) For RCC M-200 grade slabs / landings / vertical walls / waist slabs / steps for staircase.. RCC M 200 FOR WALL Lift 0.0 to 5.00 m AboveGL, Steining wall Increse HT of wellfor saftey of Animal |
| 5 | Item No. 4: - Providing and fixing in position for steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns canopies, stair cases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and shedules including cutting, bending, hooking the bars, binding with wires, or tack welding and supporting as required etc. complete(including cost of binding wire).@ 80 kg/cum of concrete. Lift 0.0 to 5.00 m |
| 6 | Item No.5 :- Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A |
| 7 | Item No.6 :- Providing and fixing mild steel grill work for windows/ventilators of 20 Kg./Sqm. as per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. ON WHOLE AREA OF SUPPLY WELL COVERED BY GRILL |
| 8 | Item No.5 :- Providing and fabricating structural steel work in single stanchions composed of R.S.J. channel, etc. with caps, bases, mild steel plastes angles, anchor bolts etc. as per detailed design and drawing or as directed including cutting, fabriction, hoisting, hoisting, errecting, fixing in position, making reveted/bolted/welded connection and one coat of anticorrosive paint, and over it two coats of oil painting etc. complete. ISMB 250x 125 mm Add 20% for hoisting arrangement |
| 9 | Item No.6 :- Providing, constructingHorizantal Bore as per GSDA certificate and as per of Engineer in charge, till the completion of work as directed by the Engineer in charge. |
| 10 | Item No. 7. Providing and fixing M.S. ladder 0.50 m wide consisting of 75 mm x 10 mm M.S. flats stringer and steps of 16 mm diameter bars in double row about 25 cm c/c including all fixtures cutting holes, welding, anchoring and applying three coats of anti corrosive paint etc. complete as directed by Engineer Incharge. M. S LADDER GL TO FLOOR SLAB |
| 11 | SUB WORK NO.02:-Pumping MachineryItem No.1 Providing erecting and giving test ofSubmersible Pumpsets conforming to is 8034 and motor conforming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene impeller. Motor suitable for working on 415 V + 10% .3 Ph., 50 Hz. A.C. supply Cable guard, thrust carbon/fibre beaning to accept entire hydraulic thrust, waterproof winding shall be Provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design antithrust stream lined non return valve shall be Provided with the pum. Suitable suction strainer shall also be provided. 3 core single / double run copper conductor submersuble type flat cable 3m and 2 pairs of erection clamps shall be provided along with the pump rates per pump upto 20 stages are as below. Submesible pump set 150 mm dia ( with Bronze? Stainless steel (CF8M) upto 8 stages 10 B.H.P.min head -54MQ 26096 Lit/hr |
| 12 | Item No. 2 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.I.G.-4 with contractor rating 16 amp. |
| 13 | Item No. 3 Supplying and erecting plain copper conductor PVC insulated flexible cable as per IS 694/1990 of following grade upto 1100 volts. CB 1-3 core - 4 sq mm PVC cable switch room is on left bank of river at a dist 200 m from supply well |
| 14 | Item No. 4 Providing and fixing of steel clamp fabricated from M.S. flat 65 mm x 6 mm 1 m length including nut bolts and washers. M.S. Clamp. |
| 15 | Item No. 5 Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. completeas per IS-1239/2004. 50 mm dia. G.I. Heavy Class. |
| 16 | Medium 25 mm dia pipe for casing of cable over Nalla |
| 17 | Item No. 6 Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge 50 mm dia. G.I. Heavy Class. |
| 18 | Medium 25 mm dia pipe for casing of cable over Nalla |
| 19 | Item No. 7 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) Sluice valve 50 mm dia. |
| 20 | Non Return valve - 50 mm dia. |
| 21 | Item No. 8 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) Sluice valve 50 mm dia. |
| 22 | Non Return valve - 50 mm dia. |
| 23 | Item No. 9 Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB32 A/40-4Pole, 3 Phase. |
| 24 | Item No.10 Supplying and erecting cupboard for enclosing switchgears or for any other purpose made from selected marine plywood planks 19 mm thick duly varnished/ painted from inside and from outside with brass hinges and locking arrangement with suitable lock with keys in duplicate. Cupboard shall be duly grouted with suitable size of iron work in wall at the bottom. (Size of cupboard shall be specified in the estimate) |
| 25 | Item No.11 L.T. current transformer with wound/bar primary 10/5 Amp, ratio with 15 VA burden erected in provided M.S. box duly secured with inslulting materials and connected to the meter. L.T. Transformer |
| 26 | Item No. 12 Providing and erecting main switch or ISI mark - Amp. |
| 27 | Item No. 13 Providing and fixing frame work for pannel board near well with ISMC 100x50 and ISA 35x35x6 mm etc.complete. M.S.Frame pannel board |
| 28 | Item No. 14 Supplying and erecting PVC pipe \"B\" class 25 mm to 40 mm for eneclosing PVC cable.PVC cable. |
| 29 | Item No. 15 Supplying and erecting galvanised cast iron earth plate 60x60x0.6 cm buried in specifically prepared earth pit 1:5 m below ground level with 30 kg Charcoal and Salt in alternatre layers necessary length of double G.I. Earth wire 8 SWG connected to plate with cadmijm plate G.I. nut bolts 12 mm dia. with bituminous compound and run through 12 mm dia .G.I. pipe 3 m long remaining portion of G.I. wire from surface of earth to switch gear in PVC ippe upto accessible height duly sealed at both ends by bituminous compound complete connected to the nearest switch gear with end socket as per direction and duly tested by earth tester and recording the results.Earth Plate. |
| 30 | Item no 16 Supplying and erecting \"B\" class G.I. Bend in position with necessary material.PW1-5 50 mm dia G.I. Bend |
| 31 | PW 2-5 G.I. Tee 50 mm dia. |
| 32 | Item No. 17 Making trenches of suitable width and 0.7 m deep and laying provided L.T. cable and refilling the same with screened sand bed of 0.2 m thick to embedded the cable and bricks placed on both sides length wise and top width wise all over the run and refilling the excavated earth without shone or hard material and making the surface proper with 0.15 m crown on the top. pressure gauge 100 mm dia. |
| 33 | Item No. 18 Providing and errecting voltmeter A.C. 50 Cycles / Sec. With 0 to 500 v. range flush type errected on provided M.S. 60 and errected withnecesssary PVC wireVoltmeter 144 x 144 Sq. mm. |
| 34 | Item No. 19 Providing and errecting ammeter A.C. 50 0/5 450 v. or suitable range flush type complete errected in provided M.S. box connected to supply . Ammeter 96 x 96 Sqmm. |
| 35 | Item no 20 Supplying and errecting set of 3 pilot lamp all back light with colour glasses with monitor lamp 230 volt / 250 volt errected on provided M.S. box with pannel type fuses and connected with PVC wire. |
| 36 | Item No. 21 Supplying and errecting triple pole Iron clad/metal clad switch and fuse 415/500 v. of suitable rating as below or approved make errected on original frame. I)Incoming ICTPN-32 Amp/ |
| 37 | ii)out going ICTP-16 Amp. |
| 38 | iii)For lighting ICDP-16 Amp. |
| 39 | Item No. 22 Providing and fixing M.S.E.B.kitkat set etc. complete |
| 40 | Item No. 23 Operation of pumping machinary through mobile network system |
| 41 | SUB WORK NO.03:-Rising MainItem No. 1. \"preparing the bed for the foundation and excluding back filling complete. |
| 42 | Item No. 2. Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 43 | Item No. 3. Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 44 | \"Item No. 4. Providing and supplying in standard lengths Polyethelene Pipes, conforming to latest version ofIS 4984: 2016,14151 ; 12786; 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint, excluding coupler / specials, including transportation and freight charges inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GOI & GOM in all respect etc. complete. \"140 mmHDPE6 kg/sqcm PE - 100 |
| 45 | Item No. 5 \"Lowering laying and jointing HDPE /MDPE pipes in proper positionincluding all specials by Compression fitting / Electrofusionjointing procedure including hydraulic testing as per relevent IS Code complete with all materials for jointing procedures like Electrofusion machine, Electric mirror/ heater / But fusion welding machine with hydraulic jack, top laoding clamp etc pump and accessories for hydraulic testing and all labours as directe by engineer incharge as per IS - 7634 Part II. \"140 mmHDPE6 kg/sqcm PE - 100 |
| 46 | Item No. 6. \"Providing ISI mark GI. pipe of following class and dia.including all statutory duties & taxes such as GST levied by GOI & GOM in all respect,inspection charges, transportation to stores, etc. complete as per IS-1239/2004. \"One coupler shall be provided with each full length of pipe cost of which is included in rates below. \"150 mm GI Pipe Medium FOR Nalla crossing |
| 47 | Item No. 7. Providing double flange sluice valve confirming for IS-2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all taxes transportation etc. complete.80 MM Scour Valve |
| 48 | Item No. 8. Providing and supplying Air Valves as per IS-14845 and MJP’s standard specifications double orifice type combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including all taxes such as GST leivied by GOI and GOM in all respect railway freight, inspection charges, unloding from railway wagons, loading into truck, transportation upto departmental stores / site, unloding and stacking etc. complete. 50 mm Doubleball flanged TYPE PN 1 |
| 49 | Item No. 9. Hydraulic testing of H. D. P. E./M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. \"140 mmHDPE6 kg/sqcm PE - 100 |
| 50 | Item No. 10. Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour etc. complete either underground or in vertical position, as directed by Engineer-in-charge. \"150 mm GI Pipe Medium FOR Nalla crossing |
| 51 | \"Item No. 11. Lowering, laying and jointing in position followingC.I.D/F Reflex valves, Butterfly valves and Sluicevalves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 80 MM |
| 52 | Item No.12. Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves). 50 mm Doubleball flanged TYPE PN 1 |
| 53 | Item No. 13. Providing and fixing position air valve shaft including providing and fixing G.I. Medium Class or 6 mm thick M.S. pipe shaft 2.70 M. long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air vlave tee including encasing\"of vertical shaft on PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fxong of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee. Etc. complete. As per type designed and as directed by Engineer - In - charge . Upto 150 |
| 54 | Item No. 14. Filling in plinth and floors / trencheswith approved excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction complete. |
| 55 | Item No. 15. Proiding & supplying of electro fusion HDPE Specials in accordance with BS EN12201:Part-3 suitable for drinking water with in black blue colour manufactured from compounded PE100 virgin polymer and compitable with PE 100virgin polymer and compitable with PE 80 /PE100 pipes,in pressure rating SDR11 with min PN 12.5 rated for water application and shall be inclusive of all cost such as testing,inspection charges,transportation upto store,transit insurance,loading unloding,stacking excluding GST le ied by GOI & GOM in all respect. etc complete. 10% of cost Pipe |
| 56 | Item No. 16. Providing and constructing B.B.masonary valve chamber with 15 cm 1;3;6proportion PCC bedding excluding excavation Bb masonary in CM 1;5 PROPORTION PRECAST rcc frame and cover etc complete as directed by engr in chargesize .60x.45x1.20 m for scour valve |
| 57 | Item No. 17. Providing and laying in situ following grades of C.C. of trap/granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing, etc. complete. |
| 58 | SUB WORK NO.04:-RCC ESR OFCAPACITY40000LITERS,STAGING HT.1 2M & BEARING CAPACITY 10 TItem No :- 1 Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for ESR having Capacity upto 500 Cum. and not more than 6 m c/c for ESRs having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder out side, stainless steel Ladder in container, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. piperailing around walk way and top slab, providing spiral staire case from ground level to roof level,M.S.grill gate of 2 mtr.height with locking arrangement of approved design. B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of Acrylie emulsion with silicon additives paint to the structure including roof slab epoxy painting to internal surface & anti termite treatment for underground parts of the structure. and giving satisfactory water tightness test as per I.S. code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge.ESR 40,000 liters12 M staging Ht |
| 59 | Item No :- 2 Providing and supplying ISI standard welded CI double flanged pipe including all taxes (central & local) railway freight, insurance, unloading from railway wagon, loading into truck transport to store / site, unloading, stacking etc. complete as directed by Engineer -in- cahrge. (for 2.75 m bare pipe) 150 mm dia C I D/F pipefor Inlet, out let ,Over Flow & Washout ,Bye Pass Arrangment |
| 60 | Item No :- 3Providing double flange sluice valve confirming for IS-2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all taxes transportation etc complete. 150 mm dia PN 1. For,Wash Out, & ByePass |
| 61 | 150 mm diafor out let |
| 62 | Item No :- 4Providing and supplying ISI standared c. I.Flanged specials &fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M. S. nut bolts coated or otherwise protected from rusting and suitable for D.I.pipes including cost of labour ,materials, and transportation to stores / site, loading and unloadingincluding all such as GST levied by GOI & GOM in all respect, complete as per IS-9523. 80 to 300 mm dia. |
| 63 | Item N0 :-5Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S.Angles ( 50mm x 50mm x 6mm) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 cm fastening the wire and painting the M.S.Angles with one coat of red lead primer and two coats of paintingetc.complete. |
| 64 | Item No.:- 6 Providing and fixing Wicket gate 2.5 M wide for compound with 40 mm dia G.I. pipe, approved grill work, RCC M-150 side pillars of 25 cm x 40 cm x 2.5 M height, its foundation, finishing, painting, etc. complete. |
| 65 | SUB WORK NO.05:-Distribution System Item No. 1. Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling, by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means.Cement Road |
| 66 | Item No. 2. Excavation for foundation / pipe trenches in earth soils of all types, Sand,gravel and soft murumincluding removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 67 | Item No. 3. Excavation for foundation / pipe trenches in WBM IN hard murum and boulder WBM roadincluding removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 68 | Item No. 4. \"Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).\"140mmPVC 4 kg/sqcm |
| 69 | 110mmPVC 4 kg/sqcm |
| 70 | 90mmPVC 4 kg/sqcm |
| 71 | 75mmPVC 4 kg/sqcm |
| 72 | \"Item No. 5 Providing PVCspecails complete \"10% of cost pipe |
| 73 | \"Item No. 6. Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete (with cement solvent joint / ring fit joint). \"140mmPVC 4 kg/sqcm |
| 74 | 110mmPVC 4 kg/sqcm |
| 75 | 90mmPVC 4 kg/sqcm |
| 76 | 75mmPVC 4 kg/sqcm |
| 77 | Item No. 7. \"Hydrulic testing of PVC pipe line to specified pressure including cost of all materials and laboue and water for testing for specified length including cuttig, placing end cap making arrangment for filling safe water using resiprocating types pump which should be able to provide specified test pressure gauges and other necessary equipments,labour, operation charges, etc. required for testing. the rate under this item shall also include cost of retesting, if necessary and reinstating to original position. \"140mmPVC 4 kg/sqcm |
| 78 | 110mmPVC 4 kg/sqcm |
| 79 | 90mmPVC 4 kg/sqcm |
| 80 | 75mmPVC 4 kg/sqcm |
| 81 | Item No. 8. Providing double flange sluice valve confirming for IS-2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all taxes transportation etc. complete.\"80 mm dia PN 1. |
| 82 | 150 mm dia PN 1. |
| 83 | Item No. 9. Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) \"80 mm dia PN 1. |
| 84 | 150 mm dia PN 1. |
| 85 | Item No.10. \"Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 100 mm x 225 mm (20 kg) |
| 86 | Item No. 11. Filling in plinth and floors / trencheswith approved excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction complete. |
| 87 | Item No. 12. Providing and laying in situ following grades of C.C. of trap/granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing, etc. complete. In PCC M-150 |
| 88 | Item No. 13. Provding and constructing RCC CATTEL TROUGH as per drawing and design as per directed by engineer |
| 89 | SUB WORK NO.06:-MISCELLANEOUS WORKSItem No 1:- Commisioning running and maintaining the scheme to quantites, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP/ Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge.Note:Required chemicals to be supplied by Department free of cost and electricity bill will also be paid by the Depertment. For single village without WTP one Months |
| 90 | SUB WORK NO.07:-Tap Connection Item No.:- 1 Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in A) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe For MDPE/UPVC Pipe Service Connection on Disribution mainA) With Road Crossing |
| 91 | B) WithoutRoad Crossing |
AI Tender Summary
Tender Timeline
Apr 01, 2022
11:30 IST
Tender Published
Tender notice published.
Completed
Apr 07, 2022
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedApr 07, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedApr 08, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender