| 1 | Wiring points for light with 1.5 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along withthe reinforcementbefore concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copperconductorcable as earth continuity wire and Modulartype switch & ceiling rose / angle / batten holder on 3 mm thick phenolic Laminated backalite sheet etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No. 138C + 187A) |
| 2 | Same as item No.(1) but for two way Light Points.P.W.D.S.O.R. 2016 S.I. No. 139 ( C ) +187 A |
| 3 | Same as item No.(1) but for fanandlight duty exhaust fan.P.W.D.S.O.R. 2016 S.I. No. 140 (C ) + 187 A |
| 4 | Same as item No.(1) but for5 Amp plug point with Modulartype switch and socket etc.P.W.D.S.O.R. 2016 S.I. No.141 (C ) + 187 (C ) |
| 5 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No.1307 (C ) |
| 6 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No.221 (C ) |
| 7 | Supply and wiring of submain 2 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with Two number 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.P.W.D.S.O.R. 2018 S.I. No.291 (G ) |
| 8 | Supply and wiring of submain 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with Two number 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.P.W.D.S.O.R. 2018 S.I. No.278 (C ) |
| 9 | S/F of hexagonal fan box with hexagonal side of approx 80 mm in length fabricated from 16SWG M.S. sheet incorporating 10 mm dia, M.S. round bar duly bent for supporting fan hanger dully painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., Required for proper completion of the work. P.W.D.S.O.R. 2018 S.I. No.1149 |
| 10 | Supply & fixing ofLED Tube Light with battern suitable for up to 1 x 22 watt LED Tube light complete including tube etc on surface complete in all respect P.W.D. S.O.R. 2018 S.I. No.1413 |
| 11 | Supply & fixing ofLED Tube Light with battern suitable for up to 2 x 22 watt LED Tube light complete including tube etc on surface complete in all respect P.W.D. S.O.R. 2018 S.I. No.1414 |
| 12 | Add for fixingoftubefitting aspendentwithtwonumber 19 mmdia 16gaugerigidsteelconduitdoublechecknuts: spring loaded flanges or M.S. hookfabricated from 25 mm x 3mmflatirondulygroutedintheceilingupto 3.5 height of ceiling including painting with synthetic enamel Paint along with supply of all materials , labour T & Petc. required for proper completion of work .P.W.D.S.O.R. 2018 S.I. No.1143 |
| 13 | S/F of 9 Watt LED bulb |
| 14 | Making hole in the wall for exhaust fan and finishing properly completeinallrespects.P.W.D.S.O.R. 2018 S.I. No.1121 |
| 15 | Supply and fixing ofElectronic FanRegulator 120-280 VISI marked, on the existingswitch board including making connections,requiredmaterial,labourT&Petc.for proper completion of work to the satisfaction of Engineer Inchargeof work. P.W.D.S.O.R. 2018S.I. No.1203 (A) |
| 16 | S/F of 3mmthickbakelitesheetcover round /hexagonal Type for fan box complete with all material ,labour ,T&P as per direction of E/I |
| 17 | S/Fof 3mmthick Al. sheet junction box cover,Complete with all material labour ,T&P As per direction of E/I |
| 18 | Supply and fixing of flush / surface mountingTPN distribution board without MCBcomplete in all respects as directed at site by E / IP.W.D.S.O.R. 2018 |
| 19 | 4 way T.P.N. (S.I. No.1026ACat C) |
| 20 | Supply and fixing of6 Amp. To 32 Amp. MCB (10 K A ) .P.W.D.S.O.R. 2018 S.I. No.1002 Cat B |
| 21 | Suppy and Fixing of 4 pole MCB 10 KAP.W.D.S.O.R. 2018 |
| 22 | 40 Amp.(S.I. No.1020 Cat A |
| 23 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material Labour T&Petc required for proper completion of work. P.W.D.S.O.R. 2018 S.I. No.1139 A |
| 24 | Supplyand burring of safe Earthing ElectrodeT – 19 (Hot Dip Galvanized) Length 3000 mm outer pipe 50 mm inner pipe 25 , terminal Dia 12 mm outer G.I. pipe of 16 swg and inner G.I. pipeof 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover and masonry housing P.W.D.S.O.R. 2018 S.I. No.725 B |
| 25 | Supplying & Laying of 25mm x 3 mm G.I. Strip for earth Electrode directly in the ground as required complete in all respects. P.W.D.S.O.R. 2018 S.I. No.716 |
| 26 | S / F of 100 mm dia G.I.pipe \"B\" class for cable completed with supports.by 3 Nos.clamp made for 20x30 mm MS flat and suitable size of nut,bolt & Washer required for proper completion of work as per direction of E/I D.S.R. 2018Item Code No. 14.13.3 |
| 27 | Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulater standard down rod, blades including connection etc. complete as required as per direction of E/I Make :- Bajaj, Crompton or Equivalent |
| 28 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. as per direction of E/I Make :- Bajaj, Crompton or Equivalent |
| 29 | S / F of Change over switch on angle iron frame ,including the cost of labour T & P painting and other material required for proper completion of the work as per direction & satisfation of E / I 100 Amp.foure pole on 40 mm x 40 mm x 6 mm angle iron frame P.W.D.S.O.R.2018 S.I.No. 378 |
| 30 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc.complete in all respects.The instrument chamber shall be separated and shall comprise of flush type ammeter ,voltmerer ,selector switches for ammeter and voltmeter ,instrument fuse ,current transormer etc. |
| 31 | The board shall have suitable capacity electroytic aluminium busbars as per IS 8623 istulate with heat shrink sleving and mounted on non hygroscopic supports such as CMC / DMC support with deteachable side covers and shall besuitable for extension on the sides The switches shall becomplete with suitable cable end boxex ,reverse entery boxex in case of pedestaal type ,cable sockets compression glands and including lamp on incoming etc. |
| 32 | The Job includes the grounting of the board as per direction of E/I. All outgoing switches of 100 amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm / 2 mm cubicle type switch board shall be ofcat A B & B - II and pedestal type for cat -B and C only.PWD SOR 2018 S.I. No. 801 B |
| 33 | Wall Mounted Panel 1,2,3,4 Incoming 100 Amp T.P.N 1 No.100 Amp. Al. Busbar of suitable lenthoutgoing 63 Amp TPN 3 Nos.63 Amp TPN 2 Nos. Spare |
| 34 | Supply & laying ofaluminium conductor PVCinsulatedarmoured served sheathed cables 1100 Volts grateata depthofbelowground level over a cushion of 75mm. below groundlevel over a cushion of 75mm. thicksand alround and protected with burnt bricks on sides and on top.On surface the cable run shallbefixedonM.S. clamps etc. ofsuitablesizeorasdirectedby the Engineer-incharge, complete in all respects. The armouringof the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018S.I. 501 |
| 35 | 10 Sq.mm 2 Core |
| 36 | 16 Sq.mm 4 Core |
| 37 | 240 Sq.mm 3 ½ core |
| 38 | Supply & Fixing of Bress nickle plated compression gland for PVC insulated and around served sheathed underground cable including rubber ring etc complete in all respect PWD SOR 2018S.I. 503 |
| 39 | 10 Sq.mm 2 Core |
| 40 | 16 Sq.mm 4 Core |
| 41 | 240 Sq.mm 3 ½ core |
| 42 | Supply & fixing of plain or pin type copper tin plated cable socket (lug)to the cable leads,insulated with tapeand making connection etc.complete in all respectas per direction of E/I PWD SOR 2018S.I. 504 |
| 43 | 10Sq. mm |
| 44 | 16 Sq. mm |
| 45 | 120 Sq. mm |
| 46 | 240 Sq. mm |
| 47 | supply and fixing of 32 A. 240 V D.P. Metal rewireable type switch fuse unit on M.D.F.E. / teak wood board complete in all respect P.W.D.S.O.R. 2016 S.I. No.305 B |
| 48 | Supply and fixing of flush / surface mounting4 ways SPN distribution board with additinal metal door withought M.C.B. Complete in all respects.as directed at site by E / IP.W.D.S.O.R. 2016 S.I. No. 1022 Cat A |
| 49 | Supply and Fixing of 6 to 32 Amp.D.P. MCB 10 KA(Legrand / Lexice) P.W.D.S.O.R. 2016 S.I. No. 1009 Cat C |
| 50 | Supplying & fixing of 1 No.8 SWG G.I. Wire in 15 mm dia for earthing laid ingroundor in wall duly concealed including the cost of cement sand labour T&P other material required for proper completion of the work as directed as site(P.W.D. S.O.R. 2016 S.I. No 721 |
| 51 | Wiring points for call bell with1.5 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and Modulartype Bell Push or 2 pin socketetc. complete in all respects.P.W.D.S.O.R. 2018 S.I. No.142 (C ) |
| 52 | Supply and Fixing of Sheet Steel enclouser surface / Flush Mounting Fitted with 20 Amp.2 pin and Earth metal clad scraping earth plug and socket complete in all respect P.W.D. S.O.R. 2018 S.I. No. 1031 Cat B |
| 53 | Supply and Fixing of Sheet Steel enclouser for SP/DP MCB with nutral linc and earth terminalP.W.D. S.O.R. 2018 S.I. No. 1032 Cat B |
| 54 | Supply and fixing of flush / surface mounting12 ways SPN distribution board with additinal metal door withought M.C.B. Complete in all respects.as directed at site by E / IP.W.D.S.O.R. 2018 S.I. No. 1025 ( Cat B) |
| 55 | Supply, Installation, Testing & Commissioning of MS Pipe confirming to IS 1239 B Class medium duty with painting, fitting and necessary support. |
| 56 | 25mm dia |
| 57 | 80mm dia |
| 58 | 100 mm dia |
| 59 | Supply, Installation, Testing & Commissioning of M.S.ERW Pipe confirming to IS:1239,medium class with wrapping & coating . Cost includes digging of trench and back filling. |
| 60 | 80mm dia |
| 61 | 100 mm dia |
| 62 | Providing ISI marked stainless steel fire hydrant valve 80 mm inlet, single outlet with control and fitted with 63 mm dia instantaneous female coupling complete with blank cap and chain. |
| 63 | Providing and fixing63 mm dia 15 M long rubberized fabric lined hose including SS male and female instantaneous type coupling, machine wound with wire complete in all respects hose to IS:636 type II and coupling to IS:903-1975 with ISI certification. |
| 64 | Providing and fixing standard short size SS branch pipe with nozzle of 16 mm NB outlet with standard instantaneous type 63 mm dia coupling. |
| 65 | Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. Sheet with single or double glazed front door (with 4 mm thick glass) and locking arrangement, painted fire red with enamelled paint \"FIRE HOSE\" written on front including necessary supports approximate size. |
| 66 | 600 x 400 x 300 mm deep |
| 67 | Providing and fixingfirst aid fire hose reel wall mounting swing type fitted with 30 M x 20 mm dia high pressure RUBBER hose ISI marked SS nozzle with shut off valve and isolation valve. (IS:444). |
| 68 | Supply, installation, testing and commissioning ofButterfly Valve standard lever operated type bearing IS: 13095 Mark, with required flanges, nuts, bolts etc. complete. |
| 69 | 80mm dia |
| 70 | Supply, installation, testing and commissioning ofNon Return Valve,wafer swing check type with companion flanges, nuts, bolts etc. complete in all respect. |
| 71 | 100 mm dia |
| 72 | Supply, installation, testing and commissioning of Pressue Switch. |
| 73 | 100 mm dia |
| 74 | Providing and fixing dial type pressure gauge with isolation cock. |
| 75 | Dia 100 mm calibration |
| 76 | S/I/T/C of 25 mm dia Air Release valve |
| 77 | Providing and fixing heavy dutyarmoured cables including necessary supportclamps at ceiling level and connection lugs complete in all respects. |
| 78 | Power cable aluminium 4 core 6 sq. mm |
| 79 | Providing and fixing ABC powder type fire extinguisher ISI marked: 6 kg capacity. |
| 80 | Supply, installation, Testing & Commissioning of electrical motor driven fire pump with provision of a panel for automatic operation. |
| 81 | Head: 35 meter |
| 82 | Supply, installation, testing and commisioning of 4-zone fire alarm panel. |
| 83 | Providing , fixing of LMT speaker cum hooter in ABS body |
| 84 | Providing and fixing of MCP of approved Make. |
| 85 | Supply and laying 2X1.5 sqmm copper conductor FRPVC insulated armouredcable |
| 86 | Deep TubewellTransportation of RIG Machine Including its erection at drilling point, dismentalling after Drilling. The work also includes water supply arrangement for drilling |
| 87 | Drilling with D.C./RC. Rig machine |
| 88 | 675mm dia bore from G.L. to 50 Mtr Below Ground Level including Reaming of bore with back washing. |
| 89 | 450mm dia bore Reaming of bore with back washing. |
| 90 | Beyond 50 mtr. To 100 mtr. BGL |
| 91 | Beyond 100 mtr. To 120 mtr. BGL |
| 92 | Supply & providing Bentonite powder if required while drilling of bore hole. |
| 93 | Providing and fixing of required tubewell accessories such as M.S. reducer, Bailplug well Cap Rings and M.S. Clamp for supporting Pipe Assembly complete in all respect as per releven IS. |
| 94 | Tubewell Logging of Bore by Electrical Logger. |
| 95 | Rate of tubewell liner assembly (ERW pipe) |
| 96 | Housing Pipe 200mm dia. 6mm thick. |
| 97 | Blind Pipe 150mm dia. 5.4 mm thick. |
| 98 | sloted Pipe 150mm dia. 5.4 mm thick |
| 99 | Supply and filling of Pea gravel of 1.5 to 4.5 mm size surrounding the tubewell. |
| 100 | Development of tubewell by air compressor of 250 PSI, Capacity. |
| 101 | Development of tubewell by O.P. Unit and Bore hole pump should be 200 LPM to Depress the water level by 10 Mts. Or as approved by E/I. So as to get average yield of 1500 LPM of More at 6 Mts. Depression making water reasonable sand free as per I.S. 2800. |
| 102 | submersible pump set. |
| 103 | Switch Gear |
| 104 | Main piping and valves |
| 105 | Pressure & Depth gauge |
| 106 | Lifting tackle |
| 107 | Special tools and spanners |
| 108 | Installation |
| 109 | commissioning |
| 110 | Painting |
| 111 | Testing |
| 112 | Supply of Aquas make electronic Chlorinator of 6LPH capacity complete accessories and 100 Ltr, PVC solution tank. |
| 113 | Installation charges (1/2\" socket fixed in pipe line to provide by the department, out side Lucknow |
| 114 | Supply and erection of 9.00 Mtrs. Long S.T. pole confiring to the I.S.S. No IS2678-1960, IS 1343-1960 and 456-1965 with 1/6th over all length of pole grouted with 1:4:8 cement concrete (1 cement, 4 finesand and 8 OBB of 40 mm nominal size ) including plinthing with 2 mm nominal size stone grit 10 cm below the G.L. and 30 cm above the G.L. and plastering with 1:4 cement sand mortar painting and numbering of pole and making strip with enamel paint complete with all materials, labour and T&P etc. and also including the cartage of pole to site of work (As per specification No- 1.1 to 1.5.4)P.W.D.S.O.R.2018 S.I.No.613 |
| 115 | 410 SP-32, 9.00 Mtrs long |
| 116 | S/F of M.S. clamp for L.T. insulator suitable for S.T. pole made of 50x 6mm M.S. flat making necessary holes suitable for bolts, nut and washer duly painted with approved paint including the cost of material, labour and T&P etc. Required for proper completion of work. (As per specification No 1.2 to 1.5.4) |
| 117 | 410 SP-32, 9.00 Mtrs long |
| 118 | S/F of earth clampsuitable for following types of supports- (As per specification No 24) |
| 119 | 410 SP-32, 9.00 Mtrs long |
| 120 | S/F of G.I. shackle strips of 355 x 40 x 4 mm size including holes for shackle insulator\"s pins and bolts nuts etc including the cost of material, labour and T&P required for proper completion of work.(As per specification No-6) |
| 121 | S/F of shackle insulator 100 x 115 mm size with M.S. Bolt nut and washer etc. complete with all material,labour and T&P required for proper completion of work.(As per specification No-7) |
| 122 | Supplying stringing and sagging over head L.t. lines with A.C.S.R. conductors like Dog, Raccoon, Rabbit or weasel confiring to the relevant I.S. specification of S.T. poles/P.C.C. poles/Rails/Joist, service brackets including the cost of all material, labour T&P required for proper completion of work.(As per specification No-13 to 13.3) P.W.D.S.O.R.2018 S.I.No.627 |
| 123 | Rabbit |
| 124 | Weasel |
| 125 | Supply and erection of overhead lines with 6SWG G.I. wire on S.T. pole required for earth wire with binding etc. including the cost of allmaterial, labour and T&P required for proper completion of work as pe direction of E/IP.W.D.S.O.R.2018 S.I.No.628 |
| 126 | Supply and fixing of hexagonal guard of6 SWG G.I. wire with binding including the cost of allmaterial, labour and T&P required for proper completion of work as pe direction of E/I.(As per specification No-14) |
| 127 | Supply and erection of stay set atleast 3.5 mters away from the supports or as per actual site requirement complete with G.I. 16mmx1.8Meters long stayrod 152x152x6mm G.I. anchor plate, thimble, stay clamps stay insulator 75x125 mm and 7/10 SWG, G.S. stay wire duly grouted in 1:4:8 cement concrete ( 1 cement, 4 fine sand and 8 OBB 40 mm nominal size) includingcost of allmaterial, labour and T&P required for proper completion of work as pe direction of E/I.(As per specification No-9 |
| 128 | Making suitable earthing of S.T. pole with 2.5 Mtrs Long 20 mm dia M.S. rod with 7/16 SWG, G.S. wire in 15 mm dia 2.0 Mtrs Long G.I. pipe duly clamped with three No clamps and binding on poles including cost of all material,labour and T&P required for proper completion of work.(As per specification No-12) |
| 129 | Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole. Lighting arrestor and transformer. The rates include the cost of all material, labour and T&P etc. required for proper completion of work as per specification and direction of E/I. |
| 130 | S/F of following type of G.I. pipe \"B\" calss for cable clamped with supports by 3 Nos clamp made of 20x3 mm MS flat and suitable size of nut, bolt and wadher required for proper completion of work as per direction of E/I. |
| 131 | 80 mm dia (6.98Kg/M) |
| 132 | Supply & fixing ofLEDstreet lightfittinghaving powder coated die cast Aluminnium body and Diffuser with driver set suitable or 52 watt to 72 watt conforming to IP 65 and above protection complete in all respect PWD sor 2018 S.I. No. 1422 |
| 133 | S/F of 63 amp.415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on Angle Iron FramePWD SOR 2018 S.I. No. 316 Cat - B |
| 134 | S F of 2 x 4 sq. mm weather proof twine core Al. cable |
| 135 | Supply & laying ofaluminium conductor PVCinsulatedarmoured served sheathed cables 1100 Volts grateata depthofbelowground level over a cushion of 75mm. below groundlevel over a cushion of 75mm. thicksand alround and protected with burnt bricks on sides and on top.On surface the cable run shallbefixedonM.S. clamps etc. ofsuitablesizeorasdirectedby the Engineer-incharge, complete in all respects. The armouringof the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018S.I. 501 |
| 136 | 240 Sq.mm 3 ½ core |