Annual Rate Contract For Repairs And Maintenance Of 33 / 11Kv Receiving Stations Falling Under The Jurisdiction Of Sub Transmission Division-Ii, Rajbagh, Srinagar For The Year 2022-23 Or Till Next Rate Contract Annual Rate Contract For Repairs And Maint
Tender Overview
Project Description
Annual Rate Contract For Repairs And Maintenance Of 33 / 11Kv Receiving Stations Falling Under The Jurisdiction Of Sub Transmission Division-Ii, Rajbagh, Srinagar For The Year 2022-23 Or Till Next Rate Contract Annual Rate Contract For Repairs And Maintenance Of 33 / 11Kv Receiving Stations Falling Under The Jurisdiction Of Sub Transmission Division-Ii, Rajbagh, Srinagar For The Year 2022-23 Or Till Next Rate Contract
BOQ
| Sl. No. | Item Description |
| 1 | Dismantalling of 11KV VCB Panel |
| 2 | Dismantalling of 33KV C&R Panel |
| 3 | Dismantalling of 33KV VCB / MOCB |
| 4 | Installation,testing and commissioningof 11KV VCB Panel complete(material to be provided by the department) |
| 5 | Installation,testing and commissioningof 33KV C&R Panel complete(material to be provided by the department) |
| 6 | Installation,testing and commissioningof 33KV VCB complete(material to be provided by the department) |
| 7 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Alsthommake |
| 8 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Easun Reyroll Make |
| 9 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Vijay Make |
| 10 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Sudhir Make |
| 11 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Electric FieldMake |
| 12 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Crompton GreevesMake |
| 13 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Allind Make |
| 14 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Pascal Make |
| 15 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of L&T Make |
| 16 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of ABB Make |
| 17 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of S&S Make |
| 18 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of BHEL Make |
| 19 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Beeco Lawrie Make |
| 20 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Stelmec Make |
| 21 | Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Southern Make |
| 22 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Alsthommake |
| 23 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Easun Reyroll Make |
| 24 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Vijay Make |
| 25 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Sudhir Make |
| 26 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Electric FieldMake |
| 27 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Crompton GreevesMake |
| 28 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Allind Make |
| 29 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Pascal Make |
| 30 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of L&T Make |
| 31 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of ABB Make |
| 32 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of S&S Make |
| 33 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of BHEL Make |
| 34 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Beeco Lawrie Make |
| 35 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Stelmec Make |
| 36 | Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCBPanels of Southern Make |
| 37 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Alsthommake |
| 38 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Easun Reyroll Make |
| 39 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Vijay Make |
| 40 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Sudhir Make |
| 41 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Crompton Greeves Make |
| 42 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Electric FieldMake |
| 43 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Allind Make |
| 44 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Pascal Make |
| 45 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of L&T Make |
| 46 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of ABB Make |
| 47 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of S&S Make |
| 48 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of BHEL Make |
| 49 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Beeco Lawrie Make |
| 50 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Stelmec Make |
| 51 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Southern Make |
| 52 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Alsthommake |
| 53 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Easun Reyroll Make |
| 54 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Vijay Make |
| 55 | Installation, testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Sudhir Make |
| 56 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Crompton Greeves Make |
| 57 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Electric FieldMake |
| 58 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Allind Make |
| 59 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Pascal Make |
| 60 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of L&T Make |
| 61 | Installation, testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of ABB Make |
| 62 | Installation, testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of S&S Make |
| 63 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of BHEL Make |
| 64 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Beeco Lawrie Make |
| 65 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Stelmec Make |
| 66 | Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Southern Make |
| 67 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Alsthom make |
| 68 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Easun Reyroll Make |
| 69 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Vijay Make |
| 70 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Sudhir Make |
| 71 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Electric Field Make |
| 72 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Crompton Greeves Make |
| 73 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Allind Make |
| 74 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Pascal Make |
| 75 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of L&T Make |
| 76 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of ABB Make |
| 77 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of S&S Make |
| 78 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of BHEL Make |
| 79 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Beeco Lawrie Make |
| 80 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Stelmec Make |
| 81 | Providing and fixing offresh male contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Southern Make |
| 82 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Alsthom make |
| 83 | Providing and fixing offresh femalecontact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Easun Reyroll Make |
| 84 | Providing and fixing offreshfemalecontact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Vijay Make |
| 85 | Providing and fixing offreshfemalecontact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Sudhir Make |
| 86 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Electric Field Make |
| 87 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Crompton Greeves Make |
| 88 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Allind Make |
| 89 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Pascal Make |
| 90 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of L&T Make |
| 91 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of ABB Make |
| 92 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of S&S Make |
| 93 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of BHEL Make |
| 94 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Beeco Lawrie Make |
| 95 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Stelmec Make |
| 96 | Providing and fixing offresh female contact setfor following 11KV VCB by way of Replacement of Damaged/Burnt Outmale contact setof same composition,type,make and class already installed in 11KV VCB panel of Southern Make |
| 97 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAlsthom Make |
| 98 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsEasun Reyroll Make |
| 99 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsVijay Make |
| 100 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSudhir Make |
| 101 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsElectric Field Make |
| 102 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsCrompton Greeves Make |
| 103 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAllind Make |
| 104 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsPascal Make |
| 105 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsL&T Make |
| 106 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsABB Make |
| 107 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsS&SMake |
| 108 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBHEL Make |
| 109 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBeeco Lawrie Make |
| 110 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsStelmec Make |
| 111 | Supply,installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSouthern Make |
| 112 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAlsthom Make |
| 113 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsEasun Reyroll Make |
| 114 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsVijay Make |
| 115 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSudhir Make |
| 116 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsElectric Field Make |
| 117 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsCrompton Greeves Make |
| 118 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAllind Make |
| 119 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsPascal Make |
| 120 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsL&T Make |
| 121 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsABB Make |
| 122 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsS&SMake |
| 123 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBHEL Make |
| 124 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBeeco Lawrie Make |
| 125 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsStelmec Make |
| 126 | Installation,testing and commissioning of11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSouthern Make |
| 127 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAlsthom Make |
| 128 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsEasun Reyroll Make |
| 129 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsVijay Make |
| 130 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSudhir Make |
| 131 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsElectric Field Make |
| 132 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsCrompton Greeves Make |
| 133 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAllind Make |
| 134 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsPascal Make |
| 135 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsL&T Make |
| 136 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsABB Make |
| 137 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsS&S Make |
| 138 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBHEL Make |
| 139 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBeeco Lawrie Make |
| 140 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsStelmec Make |
| 141 | Supply,installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSouthern Make |
| 142 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAlsthom Make |
| 143 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsEasun Reyroll Make |
| 144 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsVijay Make |
| 145 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSudhir Make |
| 146 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsElectric Field Make |
| 147 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsCrompton Greeves Make |
| 148 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsAllind Make |
| 149 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsPascal Make |
| 150 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsL&T Make |
| 151 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsABB Make |
| 152 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsS&S Make |
| 153 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBHEL Make |
| 154 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsBeeco Lawrie Make |
| 155 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsStelmec Make |
| 156 | Installation,testing and commissioning of11 KVBush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KVBush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panelsSouthern Make |
| 157 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Alsthom make |
| 158 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel ofEasun Reyroll Make |
| 159 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Vijay Make |
| 160 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Sudhir Make |
| 161 | Supply, Installation, testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Electric Field Make |
| 162 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Crompton Greeves Make |
| 163 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Allind Make |
| 164 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Pascal Make |
| 165 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof L&T Make |
| 166 | Supply, Installation,testingand commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof ABB Make |
| 167 | Supply, Installation,testingand commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of S&S Make |
| 168 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of BHEL Make |
| 169 | Supply, Installation,testingand commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 170 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Stelmec Make |
| 171 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Southern Make |
| 172 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Alsthom make |
| 173 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Easun Reyroll Make |
| 174 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Vijay Make |
| 175 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Sudhir Make |
| 176 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Electric Field Make |
| 177 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Crompton Greeves Make |
| 178 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Allind Make |
| 179 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel (MATERIAL TO BE PROVIDED BY DEPARTMENT) of Pascal Make |
| 180 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof L&T Make |
| 181 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof ABB Make |
| 182 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof S&S Make |
| 183 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof BHEL Make |
| 184 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Beeco Lawrie Make |
| 185 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Stelmec Make |
| 186 | Installation,testing and commissioning of11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Southern Make |
| 187 | Providing & fixing of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A, 33KV Isolator) with fresh one complete. |
| 188 | Fixing of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete. |
| 189 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Alsthommake |
| 190 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make |
| 191 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make |
| 192 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make |
| 193 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make |
| 194 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make |
| 195 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Allind Make |
| 196 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make |
| 197 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of L&T Make |
| 198 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of ABB Make |
| 199 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of S&S Make |
| 200 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make |
| 201 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 202 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make |
| 203 | Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Southern Make |
| 204 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Alsthommake |
| 205 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make |
| 206 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make |
| 207 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make |
| 208 | Installation,testing, commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make |
| 209 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make |
| 210 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Allind Make |
| 211 | Installation,testing, commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make |
| 212 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of L&T Make |
| 213 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of ABB Make |
| 214 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of S&S Make |
| 215 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make |
| 216 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 217 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make |
| 218 | Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt OutTripping coil of same composition, type, make already installed in 11kV VCB panel of Southern Make |
| 219 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel ofAlsthommake |
| 220 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make |
| 221 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make |
| 222 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make |
| 223 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make |
| 224 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make |
| 225 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Allind Make |
| 226 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make |
| 227 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of L&T Make |
| 228 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of ABB Make |
| 229 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of S&S Make |
| 230 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make |
| 231 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 232 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make |
| 233 | Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Southern Make |
| 234 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel ofAlsthommake |
| 235 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make |
| 236 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make |
| 237 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make |
| 238 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make |
| 239 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make |
| 240 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Allind Make |
| 241 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make |
| 242 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of L&T Make |
| 243 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of ABB Make |
| 244 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of S&S Make |
| 245 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make |
| 246 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 247 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make |
| 248 | Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt OutClosing coil of same composition, type, make already installed in 11kV VCB panel of Southern Make |
| 249 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Alsthommake |
| 250 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Easun Reyroll Make |
| 251 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Vijay Make |
| 252 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Sudhir Make |
| 253 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Electric Field Make |
| 254 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Crompton Greeves Make |
| 255 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Allind Make |
| 256 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Pascal Make |
| 257 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of L&T Make |
| 258 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of ABB Make |
| 259 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of S&S Make |
| 260 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of BHEL Make |
| 261 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 262 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Stelmec Make |
| 263 | Supply, Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Southern Make |
| 264 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Alsthommake |
| 265 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Easun Reyroll Make |
| 266 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Vijay Make |
| 267 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Sudhir Make |
| 268 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Electric Field Make |
| 269 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Crompton Greeves Make |
| 270 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Allind Make |
| 271 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Pascal Make |
| 272 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of L&T Make |
| 273 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of ABB Make |
| 274 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of S&S Make |
| 275 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of BHEL Make |
| 276 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make |
| 277 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Stelmec Make |
| 278 | Installation,testing and commissioning of11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Southern Make |
| 279 | Providing and fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps) |
| 280 | Fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps) |
| 281 | Providing and fixing of 33KV Post Insulatorsby way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) |
| 282 | Fixing of 33KV Post Insulatorsby way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) |
| 283 | Providing and fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type) |
| 284 | Fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type) |
| 285 | Providing and fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damagedoneconfirming to IS:2099 standards (porceline type) |
| 286 | Fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damagedoneconfirming to IS:2099 standards (porceline type) |
| 287 | Providing and fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) |
| 288 | Fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) |
| 289 | Supply,installation,testing and commissioning of 33KV C.T(3-core)confirming to IEC:185 and IS:2705 (part-1 to 4) standardsof ratio 300-150/5-5-5A/ 250-125/5-5-5A)outdoor type |
| 290 | Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be provided by the department) outdoor type |
| 291 | Supply, installation,testing and commissioning of33KV P.Tof (110V/v3) confirming to IS:3156 (part-I to Part-III) outdoor type |
| 292 | Fixing,installation,testing and commissioning of fresh 33KV PT (110V/v3)confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type |
| 293 | Providing and fixingof 33KV isolator 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards with earthing blade |
| 294 | Providing and fixingof 33KV isolator 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards without earthing blade |
| 295 | Fixing,installation,testing and commissioning of fresh 33KV isolators 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade) |
| 296 | Providing, Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. |
| 297 | Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. (material to be supplied by the department) |
| 298 | Providing,Installation,Testing and commissioning of 11KV G.OSet 600 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one |
| 299 | Installation,Testing and commissioning of 11KV G.OSet 800 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V)(material to be supplied by the department) |
| 300 | Providing, fixing, installation, testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards with earthing blade |
| 301 | Providing, fixing, installation, testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards without earthing blade |
| 302 | Installation,Testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards (with earthing blade/without earthing blade )(material to be supplied by the department) |
| 303 | Providing, Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. |
| 304 | Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damagedoneheavy duty 600amps. (material to be supplied by the department) |
| 305 | Providing and fixing of 33KV Drop out setwith porcelaine insulatorby way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 306 | Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department) |
| 307 | Providing, Installation,Testing and commissioning of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 308 | Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department) |
| 309 | Oil Toping in 33/11 KV Power Transfromersand 33KV MOCB\"s (Transformer oil to be supplied by the department) |
| 310 | Providing,installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers |
| 311 | Installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers |
| 312 | Providing,installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers |
| 313 | Installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers |
| 314 | Providing and fixing of Bush Rods suitable for 33/11KVPower Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one33KV side |
| 315 | Fixing of Bush Rods suitable for 33/11KVPower Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one33KV side |
| 316 | Providing and fixing of Bush Rods suitable for 33/11KVPower Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one11KV side |
| 317 | Fixing of Bush Rods suitable for 33/11KVPower Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one11KV side |
| 318 | Supply ,installation,testing and commissioning of 30V,200 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make |
| 319 | Installation,testing and commissioning of 30V,200 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make |
| 320 | Supply,installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA |
| 321 | Installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA |
| 322 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 323 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 324 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 325 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 326 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 327 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 328 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 329 | Laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 330 | Laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 331 | Laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 332 | Laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 333 | Laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 334 | Laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 335 | Laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 336 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 337 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 338 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 339 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^²1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 340 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 341 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 342 | Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 343 | Laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 344 | Laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 345 | Laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 346 | Laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^²1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 347 | Laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 348 | Laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 349 | Laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make) |
| 350 | Supply,laying,Testing,commissioning of 2Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 351 | Supply,laying,Testing,commissioning of 4Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 352 | Supply,laying,Testing,commissioning of 6Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 353 | Supply,laying,Testing,commissioning of 8Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 354 | Supply,laying,Testing,commissioning of 12Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 355 | Laying,Testing,commissioning of 2Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 356 | Laying,Testing,commissioning of 4Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 357 | Laying,Testing,commissioning of 6Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 358 | Laying,Testing,commissioning of 8Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 359 | Laying,Testing,commissioning of 12Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make ) |
| 360 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV630mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 361 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 400mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 362 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) suitable for |
| 363 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 364 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 365 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 366 | Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV120mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 367 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 368 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe 400mm^²,3-core Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 369 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 370 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 371 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV185mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 372 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 373 | Installation,testing,commissioning of 11KV ,3 core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 374 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 630mm^²,3-coreXlpe Power Cable |
| 375 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 400mm^²,3-coreXlpe Power Cable |
| 376 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 300mm^²,3-core Xlpe Power Cable |
| 377 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 240mm^²,3-coreXlpe Power Cable |
| 378 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 185mm^²,3-coreXlpe Power Cable |
| 379 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 150mm^²,3-coreXlpe Power Cable |
| 380 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 120mm^²,3-coreXlpe Power Cable |
| 381 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 630mm^²,3-coreXlpe Power Cable |
| 382 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 400mm^²,3-coreXlpe Power Cable |
| 383 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 300mm^²,3-core Xlpe Power Cable |
| 384 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 240mm^²,3-coreXlpe Power Cable |
| 385 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 185mm^²,3-coreXlpe Power Cable |
| 386 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 150mm^²,3-coreXlpe Power Cable |
| 387 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 120mm^²,3-coreXlpe Power Cable |
| 388 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 389 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 400mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 390 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 391 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 392 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 393 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 394 | Supply,installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 395 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 396 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 400mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 397 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 398 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 399 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 400 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 401 | Installation,testing,commissioning of 11KV , 1core heat shrinkablestraight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993with latest ammendments if any (3M or RAYCHEM make) |
| 402 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 630mm^²,1-core Xlpe Power Cable |
| 403 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 400mm^²,1-core Xlpe Power Cable |
| 404 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 300mm^²,1-core Xlpe Power Cable |
| 405 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 240mm^²,1-core Xlpe Power Cable |
| 406 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 185mm^²,1-core Xlpe Power Cable |
| 407 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 150mm^²,1-core Xlpe Power Cable |
| 408 | Supply, Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 120mm^²,1-core Xlpe Power Cable |
| 409 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 630mm^²,1-core Xlpe Power Cable |
| 410 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 400mm^²,1-core Xlpe Power Cable |
| 411 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 300mm^²,1-core Xlpe Power Cable |
| 412 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 240mm^²,1-core Xlpe Power Cable |
| 413 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 185mm^²,1-core Xlpe Power Cable |
| 414 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 150mm^²,1-core Xlpe Power Cable |
| 415 | Installation,Testing and commissioning of 11KV cable terminationkits (Indoor/ outdoor Type)3M or Raychem suitable for 120mm^²,1-core Xlpe Power Cable |
| 416 | Loading of 10 MVA Power Transformer to the sub station bed / platformi/c manual dragging, rotation etc (if any required) (Complete Job) |
| 417 | Loading of 6.3 MVA Power Transformer to the sub station bed / platformi/c manual dragging, rotation etc (if any required) (Complete Job) |
| 418 | Loading of 5MVA Power Transformer to the sub station bed / platformi/c manual dragging, rotation etc (if any required) (Complete Job) |
| 419 | Unloading of 10 MVA Power Transformer fromthe sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job) |
| 420 | Unloading of 6.3 MVA Power Transformer fromthe sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job) |
| 421 | Unloading of 5 MVA Power Transformer fromthe sub station bed / platformi/c manual dragging, rotation etc (if any required) (Complete Job) |
| 422 | Carriage of 10 MVA Power Transformer upto 5km |
| 423 | Carriage of 6.3 MVA Power Transformer upto 5km |
| 424 | Carriage of 5 MVA Power Transformer upto 5km |
| 425 | Carriageof Power Transformer (10/6.3/5 MVA) beyond 5km upto 10km |
| 426 | Carriageof Power Transformer (10/6.3/5 MVA) beyond 10km upto 20km |
| 427 | Carriageof Power Transformer (10/6.3/5 MVA) beyond 20km |
| 428 | Unloading of material which are to be handled with care like 33KV CT / 33KV PT etcincluding manual carriage from dumping site upto proper stacking |
| 429 | Loading of of material which are to be handled with care like 33KV CT / 33KV PTetc including manual carriagestacking site upto loading |
| 430 | Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc upto first 100mtr lead |
| 431 | Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc For every additional 50mtr or part there off |
| 432 | Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking |
| 433 | Loading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriagestacking site upto loading |
| 434 | Supply ,installation,testing and commissioning of copper Bus Bar (2ftx10mm) |
| 435 | Installation,testing and commissioning of copper Bus Bar (2ftx10mm) |
| 436 | Installation, testing & commissioningof 10 MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job |
| 437 | Installation, testing & commissioningof 6.3MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job |
| 438 | Installation, testing & commissioningof 5MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job |
| 439 | Complete Dismantelling of 10MVA Power Transformer (including assembly viz fixing of bushes, radiators, fans etc) |
| 440 | Complete Dismantelling of 6.3MVA Power Transformer (including assembly viz fixing of bushes, radiators, fans etc) |
| 441 | Complete Dismantelling of 5MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans etc) |
| 442 | Repairing of Re-Setting Links of 11 KV VCB Panel |
| 443 | Repairing of operating shaft of 11 KV VCB Panel |
| 444 | Repairing of Shower Contact of 11 KV VCB Panel |
| 445 | Repairing of Isolating Sockets of 11 KV VCB Panel |
| 446 | Repairing of High Tension Spring of 11 KV VCB Panel |
| 447 | Repairing of Tripping Shaft of 11 KV VCB Panel |
| 448 | Repairing of Rollers of 11 KV VCB Panel |
| 449 | Repairing of Latch Assembly of 11 KV VCB Panel |
| 450 | Repairing of Gear Assembly of 11 KV VCB Panel |
| 451 | Repairing of Tripping Mechanism of 11 KV VCB Panel |
| 452 | Repairing of Spring Charge Motor Assembly of 11 KV VCB Panel |
| 453 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Alsthommake |
| 454 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Easun Reyroll Make |
| 455 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Vijay Make |
| 456 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Sudhir Make |
| 457 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Electric Field Make |
| 458 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Crompton Greeves Make |
| 459 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Allind Make |
| 460 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Pascal Make |
| 461 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of L&T Make |
| 462 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of ABB Make |
| 463 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of S&S Make |
| 464 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of BHEL Make |
| 465 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Beeco Lawrie Make |
| 466 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Stelmec Make |
| 467 | Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Southern Make |
| 468 | Replacement of Re-Setting Links of 11 KV VCB Panel |
| 469 | Replacement of operating shaft of 11 KV VCB Panel |
| 470 | Replacement of Shower Contact of 11 KV VCB Panel |
| 471 | Replacement of Isolating Sockets of 11 KV VCB Panel |
| 472 | Replacement of High Tension Spring of 11 KV VCB Panel |
| 473 | Replacement of Tripping Shaft of 11 KV VCB Panel |
| 474 | Replacement of Rollers of 11 KV VCB Panel |
| 475 | Replacement of Latch Assembly of 11 KV VCB Panel |
| 476 | Replacement of Gear Assembly of 11 KV VCB Panel |
| 477 | Replacement of Tripping Mechanism of 11 KV VCB Panel |
| 478 | Replacement of Spring Charge Motor Assembly of 11 KV VCB Panel |
| 479 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Alsthommake |
| 480 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Easun Reyroll Make |
| 481 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Vijay Make |
| 482 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Sudhir Make |
| 483 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Electric Field Make |
| 484 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Crompton Greeves Make |
| 485 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Allind Make |
| 486 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Pascal Make |
| 487 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of L&T Make |
| 488 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of ABB Make |
| 489 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of S&S Make |
| 490 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of BHEL Make |
| 491 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Beeco Lawrie Make |
| 492 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Stelmec Make |
| 493 | Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Southern Make |
| 494 | Deco Spray Painting |
| 495 | Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Voltmeter 11KV/110V |
| 496 | Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Ammeter |
| 497 | Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Selector Switch- 16Amps |
| 498 | Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- LED panel Indicators |
| 499 | Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Push Button |
| 500 | Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- HRC fuse with Base -16 Amps |
| 501 | Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Voltmeter 11KV/110V |
| 502 | Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Ammeter |
| 503 | Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Selector Switch- 16Amps |
| 504 | Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- LED panel Indicators |
| 505 | Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Push Button |
| 506 | Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- HRC fuse with Base -16 Amps |
| 507 | Panel Control re-wiringwith 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc |
| 508 | Supply,installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 509 | Installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 510 | Supply,installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 511 | Installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 512 | Supply,installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 513 | Installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 514 | Supply,installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 515 | Installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel. |
| 516 | Supply,installation,testing and commissioning of Numerical/Digital Relayby way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts |
| 517 | Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provieded by the department) |
| 518 | Providing and fixing of Arcing interrupting chamberssuitable for33 KVVCB panels of different makes by way of replacement of damaged one |
| 519 | Fixing of Arcing interrupting chamberssuitable for33 KVVCB panels of different makes by way of replacement of damaged one |
| 520 | Supply,installation,testing and commissioning ofmaster trip relay 24-50 V by way of Replacement of Damaged/Burnt of ,type,make and class already installed in 11KV VCB panel |
| 521 | Installation,testing and commissioning ofmaster trip relay 24-50 V by way of Replacement of Damaged/Burnt of same type,make and class already installed in 11KV VCB panel |
| 522 | Supply,installation,testing and commissioning ofYard lights by way of Replacement of Damaged/Burnt of type already installed |
| 523 | Installation,testing and commissioning ofYard lights by way of Replacement of Damaged/Burnt of type already installed |
| 524 | Note: The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender