Repair Of Main Gate At Diet Nanakpura, Motibagh-Ii, New Delhi During 2021-22. ( Sh- Balance Work ) Repair Of Main Gate At Diet Nanakpura, Motibagh-Ii, New Delhi During 2021-22. ( Sh- Balance Work )
Tender Value
1.59 Lakhs
Estimated cost
Bid Submission
30 Mar 2022
0 days left
EMD
3180
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
safdarjung → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Of Main Gate At Diet Nanakpura, Motibagh-Ii, New Delhi During 2021-22. ( Sh- Balance Work ) Repair Of Main Gate At Diet Nanakpura, Motibagh-Ii, New Delhi During 2021-22. ( Sh- Balance Work )
BOQ
| Sl. No. | Item Description |
| 1 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 2 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 3 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 4 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 5 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 6 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 8 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in- charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage |
| 9 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type orof approved makeincluding tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 50mm average thickness |
| 10 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 11 | Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge. Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument. 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 12 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \"L\" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge. |
| 13 | Providing & applying Single pack component, solvent- free, cold applied Polyurethane modified, elastomeric liquid applied waterproofing membrane- Home Shield PU Roofkoat with excellent UV resistant capacity, Non-toxic with high SRI Index, eco friendly, low VOC & complies with the requirement as laid out in ASTMD 6083-97a, It can be applied on cementious substrates, brick & stone. Bituminous Coatings, metal, wooden substrates, paint/ coatings with application of two coats without dilution along with a self Priming Coat – 50% dilution with water. Surface should be cleaned properly with required tools & crack repairing by cement mortar mixed with latex for waterproofing allocation. Apply PU Roofkoat in 3 coats ( 1st priming coat @ 0.2 kg/Sqm and 2nd & 3rd coat @ 0.4 kg/Sqm of each coat) for complete waterproofing with Interval of 4 hours between every coat of PU Roofkoat. The material shall meet the requirement as specified in ASTM D2370-98 of elongation at break of film> 350% with geotextile fleece=50% approxThe work shall be carried out as per specification & the direction of the Engineer-in-charge. The product performance shall carry guaranteed for 10 year against any leakage.For Horizontal Surface ( With Geotextile Fleece) two coat without dilution & 1 self priming Coat 50% dilution with water @ 1.0 kg/Sqm |
| 14 | Add CPWD Cost [email protected]%(On DSR Items) |
| 15 | Deduct PWD Cost [email protected]%(On DSR Items) |
AI Tender Summary
Tender Timeline
Mar 23, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMar 30, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 30, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender