Tidel Park Ltd-TPL has published Tender For Supply, Installation, Testing And Commissioning Of Passenger And Goods Lift For The Proposed Construction Of Aerohub - Advanced Computing Design Engineering Centre (Acdec) For Aerospace And Defence Industries At Vallam Vadagal, Tender For Suppl. Submission Date for this Tender is 29-04-2022. Passenger Lift Tenders in kancheepuram Tamil Nadu. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Apr-2022 | Submission date Extension | Date | 29-04-2022 |
Sl. No. | Item Description |
1 | IMPORTANT NOTE : Bidder shall Quote their rates based on the Bill of Quantities read together with Technical Specifications, Particular Specifications,and Special conditions in Technical Specifications . |
2 | Main Building : PASSENGER LIFTS WITH DESTINATION CONTROL SYSTEM ( WITH MACHINE ROOM) - Option I |
3 | Design , manufacture, supply, installation, testing and commissioning of 1360Kgs capacity lift withMachine room type Lifts design conforming to latest lift act and modern lift with microprocesor includingAC-Gearless VVVF controller in the existing lift well / shaft having minimum speed of min1.60 m/sec with a total travel of 41.30m (approx) (Basement , Ground plus Eight upper floors, servicing 10 stops and 10Landings for Mainbuilding of Aerohub ) on same side door opening with / withoutattendent operation and with all necessary safety features and in accordance with Lift Service particulars of General / Technical Specification, Special Conditions etc. "The lift shall be of excellent quality and shall have Micro stroke push buttons, intelligent group of simplex controls, floor announcement system, Gearless machine and other features as per detailed specifications attached.The lift car shall have car operating control panels in automatic mode (with or without attendant) and from one panel in attendant mode. |
4 | The lift equipment will be installed in the machine room directly above the lift well as shown indrawings. All the lift equipments, i/c car, car doors self-levelling devices, control devices, indicators, landing doors, indicators, buffer ropes safety devices i/c all wiring connection, interconnection and all connected equipments shall be as per specifications.The work also includes all structural items in machine room and above the lift well like RCC block, & MS girders required for lift insallations & providing miscellaneous items like supports for guide rails, overhead gears, scaffoldings, sill projections, facia inside the lift well, minor building works like making sockets, holes etc.i/c making good the damages. The rate shall include approval andobtaining completion certificate from the electrical / lift inspectorate ofLocal Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. |
5 | TOTAL AMOUNT-Passenger Liftswith DCS (All 6 Liftsshall be a Car Group ) |
6 | Option II |
7 | Specification same as above but for Design , manufacture, supply, installation, testing and commissioning of 1360Kgs capacity lifts withMachine Room Less Elevators. |
8 | Main Building : GOODS LIFTS ( WITH MACHINE ROOM) - Option I |
9 | Design, manufacture, supply installation at site, testing, commissioningof Goods lift 1500 kg load capacity Machine Room Type Lifts, synchronizing motor -Gearless VVVF controller in the existing lift well / shaft having minimum speed of 1 m/sec with a total travel of 41.30mtrs (Approx).Basement, Ground plusEight upper floors, servicing 10 stops and 10 landings on same side with simplex group with/without attendant operations and with all necessary safety features and in accordance with Lift service particulars, General/ Technical specifications, Special conditions etc. |
10 | The lift shall be of excellent quality and shall have Micro stroke push buttons, intelligent group controls of four lifts/six lifts (as required), floor announcement system, Gearless and other features as per detailed specifications attached.The lift car shall have two parallel car operating control panels in automatic mode (with or without attendant) and from one panel in attendant mode. |
11 | The lift equipment will be installed in the machine room directly above the lift well as shown indrawings.All the lift equipments, including car, car doors self-levelling devices, control devices, indicators, landing doors, indicators, buffer ropes safety devices i/c all wiring connection, interconnection and all connected equipments shall be as per specifications and drawings. |
12 | The rate shall include approval andobtaining completion certificate from the electrical / lift inspectorate ofLocal Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. |
13 | TOTAL AMOUNT for Goods Lifts |
14 | Option II |
15 | Main BuildingGoods Lifts: Specification same as above but for Design , manufacture, supply, installation, testing and commissioning of 1500 Kgs capacity lifts withMachine Room Less Elevators. |
16 | Substation & Chiller PlantBuilding( Goods lift - Machine room less) Design, manufacture, supply installation at site, testing, commissioningGoods lift 1500 kg load capacity Machine Room less Lift, synchronizing motor -Gearless VVVF controller in the existing lift well / shaft having minimum speed of 1 m/sec with a total travel of 13.70mtrs (Approx) as shown in the drawing.Ground to terrace floor servicing 3 stops and 3 landings on same side with simplex group with/without attendant operations and with all necessary safety features and in accordance with Lift service particulars, General/ Technical specifications, Special conditions etc. |
17 | The lift shall be of excellent quality and shall have Micro stroke push buttons, intelligent group controls of four lifts/six lifts (as required), floor announcement system, Gearless and other features as per detailed specifications attached.The lift car shall have two parallel car operating control panels in automatic mode (with or without attendant) and from one panel in attendant mode. |
18 | The lift machine/equipment will be installed in the lift shaft as shown indrawings. All the lift equipments, including car, car doors self-levelling devices, control devices, indicators, landing doors, indicators, buffer ropes safety devices i/c all wiring connection, interconnection and all connected equipments shall be as per specifications and drawings. |
19 | The rate shall include approval andobtaining completion certificate from the electrical / lift inspectorate ofLocal Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift. |
20 | Bidders should give options for lift car Interiors. The final design selection shall be as per Owner"s requirement. |