| 1 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out soft/loose soil complete all specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and directed. |
| 3 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all specified and directed. |
| 4 | Supply and spreading locally available River Sand for covering and cushioning of UG Cable in trenches complete all as specified. |
| 5 | Supply and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified. |
| 6 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified. |
| 7 | All as per item Serial No 06 but for 70 sqmm 3.5 core |
| 8 | All as per item Serial No 06 but for 50 sqmm 3.5 core |
| 9 | All as per item Serial No 06 but for 25 sqmm 4 core |
| 10 | All as per item Serial No 06 but for10 sqmm 2 core |
| 11 | Supply, laying, jointing and testing Tubes, \"light grade\" galvanised,with all fittings and fixed complete to walls or laid under road for passing cables complete of size 40mm all as specified and directed. |
| 12 | Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for supporting of CI/GI pipes, header etc all as specified and directed by Engineer-in-Charge. |
| 13 | Supply and fixing thermoplastic polycarbonate IP65 (in accordance with IEC 60529) panels having ASTA type test certificate according to IEC 60439-2 tested at CPRI, made of high quality Polycarbonate (PC - GFS) shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane (PUR). All left or right side enclosures should have pre-moulded knockouts for side cable entry or for future extension. The panel board manufacturer shall have CPRI certification for similar panels in accordance with IEC60439-2.For better safety enclosure should withstand glow wire test at 960 Deg C in accordance with IEC 60 695-2-11 UL subject 94, should be flame retardant and self-extinguishing in nature. Degree of protection against mechanical load IK 08 (5 Joule) in accordance with EN IEC 62262, Rated insulation voltage should be 690V AC as per IEC 60664.The feeder pillar panels shall be fully wired as per latest electrical standards ready to use at site of size 1050W X 1800H X 255D MM and shall be with Floor mounting frame and canopy suitable for outdoor use. With 200A rated copper bus bar at 1.6A per Sqmm current density for 3 phase and neutral in accordance with IEC 61439-2. including taking down the old existing panel and necessary earth work and testing complete Comprising of the following:- |
| 14 | (i) INCOMING:-(a) MCCB 4 Pole 200 Amps, 35 KA Breaking capacity - 01 No(b) Multifunctioning meter (Next Gen) - 01 No (c) RYB Indication lamps - 01 Set (ii) OUTGOING :- (a) MCCB 4 Pole 100 Amps, 25 KA Breaking capacity - 03 Nos (b) MCCB 4 Pole 63 Amps, 25 KA Breaking capacity - 02 Nos (c) MCB SPN 50 Amps, 240 Volts, 10 KA Breaking capacity - 01 No(d) MCB SPN 6 Amps, 240 Volts, 10 KA Breaking capacity - 01 No |
| 15 | All as per Serial No 13 but of Size 1650W X 1800H X 255D mm and copper bus bar rated for 400A comprising of the following :-(i) INCOMING: (a) MCCB 4 Pole 315 Amps, 35 KA Breaking capacity - 01 No (b) Multifunctioning meter (Next Gen) - 01 No(c) RYB Indication lamps - 01 Set (ii) OUTGOING:- (a) MCCB 4 Pole 100 Amps, 25 KA Breaking capacity - 02 Nos (b) MCCB 4 Pole 63 Amps, 25 KA Breaking capacity - 03 Nos(c) MCB SPN 40 Amps, 240 Volts, 10 KA Breaking capacity - 02 No (d) MCB TPN 32 Amps, 415 Volts, 10 KA Breaking capacity - 05 No(e) MCB SPN 16 Amps, 240 Volts, 10 KA Breaking capacity - 02 No |
| 16 | All as per Serial No 13 but of size 600W X 1050H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING:- (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :-(a) MCCB 4 Pole 63 Amps, 25 KA Breaking capacity - 01 No(b) MCB SPN 16 Amps, 240 Volts, 10 KA Breaking capacity - 11 No |
| 17 | All as per Serial No 13 but of size 900W X 750H X 214D MM and copper bus bar rated for 150A comprising of the following :- (i) INCOMING: (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole 63 Amps, 25 KA Breaking capacity - 02 No(b) MCB SPN 16 Amps, 240 Volts, 10 KA Breaking capacity - 10 No |
| 18 | All as per Serial No 13 but of size 600W X 750H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING : (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :-(a) MCB TPN 32 Amps, 25 KA Breaking capacity - 03 Nos(b) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 05 Nos |
| 19 | All as per Serial No 13 but of size 600W X 750H X 214D MM and copper bus bar rated for 150A comprising of the following :- (i) INCOMING: (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :-(a) MCB SPN 32 Amps, 25 KA Breaking capacity - 03 Nos(b) MCB SPN 16 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos |
| 20 | All as per Serial No 13 but of size 600W X 750H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING :(a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :-(a) MCB SPN 40 Amps, 25 KA Breaking capacity - 01 No (b) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 02 Nos(c) MCB SPN 16 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos |
| 21 | All as per Serial No 13 but of size 600W X 900H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING : (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole 63 Amps, 25 KA Breaking capacity - 03 Nos (b) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 04 Nos(c) MCB SPN 63 Amps, 240 Volts, 10 KA Breaking capacity - 01 No |
| 22 | All as per Serial No 13 but of size 600W X 900H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING:- (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole 63 Amps, 25 KA Breaking capacity - 01 No(b) MCB TPN 32 Amps, 415 Volts, 10 KA Breaking capacity - 01 No(c) MCB SPN 63 Amps, 240 Volts, 10 KA Breaking capacity - 01 No(d) MCB SPN 40 Amps, 240 Volts, 10 KA Breaking capacity - 01 No(e) MCB SPN 10 Amps, 240 Volts, 10 KA Breaking capacity - 02 No |
| 23 | All as per Serial No 13 but of size 1350W X 1800H X 255D MM and copper bus bar rated for 630A comprising of the following :- (i) INCOMING:(a) MCCB 4 Pole 630 Amps, 50 KA Breaking capacity - 01 No(b)Multifunctioning meter (Next Gen) - 01 No (c) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole,400 Amps, 50 KA Breaking capacity - 03 Nos |
| 24 | All as per Serial No 13 but of size 1500W X 1350H X 255D MM and copper bus bar rated for 250A comprising of the following :-(i) INCOMING:-(a) MCCB 4 Pole 250 Amps, 50 KA Breaking capacity - 01 No(b) Multifunctioning meter (Next Gen) - 01 No (c) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole,100 Amps, 35 KA Breaking capacity - 04 Nos(b) APFC Control with 03 Nos 7.5 KVAR Power capacitors -01 Set |
| 25 | All as per Serial No 13 but of size 900W X 1200H X 214D MM and copper bus bar rated for 200A comprising of the following :- (i) INCOMING:- (a) MCCB 4 Pole 200 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 25 KA Breaking capacity - 03 Nos (b) MCB TPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 05 Nos |
| 26 | All as per Serial No 13 but of size 900W X 1200H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING: (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :-(a) MCCB 4 Pole, 63 Amps, 25 KA Breaking capacity - 02 Nos (b) MCB SPN 50 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos(c) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 06 Nos |
| 27 | All as per Serl No 13 but of size 900W X 1050H X 214D MM and copper bus bar rated for 150A comprising of the following :- (i) INCOMING:-(a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set (d) RYB Indication lamps - 01 Set (ii) OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 25 KA Breaking capacity - 03 Nos (b) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 07 Nos |
| 28 | All as per Serial No 13 but of size 900W X 1200H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING:- (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 25 KA Breaking capacity - 03 Nos (b) MCB SPN 50 Amps, 240 Volts, 10 KA Breaking capacity - 08 Nos |
| 29 | All as per Serial No 13 but of size 900W X 1200H X 214D MM and copper bus bar rated for 150A comprising of the following :- (i) INCOMING: (a) MCCB 4 Pole 125 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole, 100 Amps, 25 KA Breaking capacity - 01 No (b) MCB TPN 50 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos(c) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 02 Nos |
| 30 | All as per Serial No 13 but of size 900W X 1050H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING:- (a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 25 KA Breaking capacity - 03 Nos (b) MCB SPN 40 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos(c) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos |
| 31 | All as per Serial No 13 but of size 900W X 750H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING:- (a) MCCB 4 Pole 125 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCCB 4 Pole, 100 Amps, 25 KA Breaking capacity - 01 No (b) MCB TPN 32 Amps, 415 Volts, 10 KA Breaking capacity - 01 No(c) MCB SPN 32 Amps, 240 Volts, 10 KA Breaking capacity - 03 Nos |
| 32 | All as per Serial No 13 but indoor type of size 900W X 750H X 214D MM and copper bus bar rated for 150A comprising of the following :- (i) INCOMING : (a) On load changeover switch 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(c) RYB Indication lamps - 01 Set(d)Multifunctioning meter (Next Gen) - 01 No(ii) OUTGOING :- (a) Fully automatic star delta starter (including MPCB, Overload protection, Single Phasing Protection & Phase sequence corrector) 20 HP Cap - 02 Nos (b) Fully automatic star delta starter (including MPCB, Overload protection, Single Phasing Protection & Phase sequence corrector) 10 HP Cap - 01 No (c) Starter DOL 0.25 HP (Including Contactor and Overload Relay) - 03 Nos (d) MCB SPN 40 Amps, 240 Volts, 10 KA Breaking capacity - 02 Nos |
| 33 | All as per Serial No 13 but of size 600W X 1050H X 214D MM and copper bus bar rated for 150A comprising of the following :-(i) INCOMING:-(a) MCCB 4 Pole 100 Amps, 35 KA Breaking capacity - 01 No(b) Voltmeter with selector switch - 01 Set(c) Ammeter with selector switch - 01 Set(d) RYB Indication lamps - 01 Set(ii) OUTGOING :- (a) MCB SPN 63 Amps, 240 Volts, 10 KA Breaking capacity - 08 Nos Note for item No 13 to 32 :- (a) All MCCBs shall be rated for 415 volts and shall have adjustable thermal magnetic release setting.(b) Rate quoted shall be including all materials such as MCCBs, MCBs, Multifuntioning meter, Volt meter, Ammeter, Indicating lamps, Star delta starters, Cable glands etc.(c) All cable lugs used shall be of copper. |
| 34 | Material & Labour for Earthing complete with Galvanised MS earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size 32 x 6 mm thick, soldered and riveted to earth plate. Earth strip will be protected by using 40mm dia bore GI pipe light grade. The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metres etc complete all as shown in electrical plate No. 3 of SSR Part-I 2009,connected to earthing test point all as specified or indicated including testing on completion. |
| 35 | Supply and Fix On load change over switch 63A, 4 pole, 415 Volt, 50 Hz with metal enclosure made out of 3.15 mm thick powder coated sheet metal enclosure of suitable size including fixing arrangement with lux and Cable gland etc, complete all as specified and directed. |
| 36 | Amount of Credit Schedule shall be deducted to arrive the Contract Sum. |