Public Administrative Department Local Bodies Closing in 0 days TDR #31566975

Providing Of Fixing Of Hall Room Toilet In New General Choupal At Beholi Road Mc Samalkha Providing Of Fixing Of Hall Room Toilet In New General Choupal At Beholi Road Mc Samalkha

Issued by Local Bodies · samalkha, Haryana
Tender Value
76.05 Lakhs
Estimated cost
Bid Submission
05 Apr 2022
0 days left
EMD
1.52 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
samalkha → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Of Fixing Of Hall Room Toilet In New General Choupal At Beholi Road Mc Samalkha Providing Of Fixing Of Hall Room Toilet In New General Choupal At Beholi Road Mc Samalkha

BOQ

Name of Work: Providing of fixing of Hall Room Toilet in New General Choupal at Beholi Road MC Samalkha
Sl. No. Item Description
19.18-Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3
27.47.1-Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in :- Cement mortar 1:4 (1 cement : 4 coarse sand)
37.22.1-Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :- Cement mortar 1:4 (1 cement : 4 coarse sand)
47.20.1-Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in :-Cement mortar 1:4 (1 cement : 4 coarse sand)
56.9.1-Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size)50 mm thickDetails of cost for 10 sqmMATERIAL:-Cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (z
66.33.3-J. STEEL REINFORCEMENTSteel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Cold twisted barsMATERIAL:- (B0041+CA011+LS004)LABOUR:- (LB003+LB008+LS004)
76.1.6-1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)Details of cost for 1 cumMATERIAL:- (B0017+B0019+CA012+CA008+B0036+CA009+B0029CA015)LABOUR:- (LB032+LB008+LB002+PM001+PM009+LS004)
833.9.3-Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia
99.58.5.2-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expa
109.57.2-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
1133.14-Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
1228.39-Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of 2 coats of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brush able. Apply the paste on surface with brush. Leave the surface for drying for at least 4 - 6 hours to getelastomeric membrane. After this application, make one more layer of rough cementitious membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed.
1323.8.10.5-Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.8 Modules
1423.8.10.4-Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.4 Modules
1523.6.6.4-Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.MS pipe of 40 mm dia.
1623.3.5.3-Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group C
177.20.2-Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in :- Cement Mortar 1:6 (1 cement : 6 coarse sand).
184.16.1.3-Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mmDetails of cost for 60m length of a pipe of an average dia. say 450mm. Slope assumed 1 in 200.Earth work and filling- Minimum depth of trench 0.75+0.45= 1.20m, Average depth = (1.50+1.20)/2
1923.3.1.3-COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group C
2022.98.1-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :-25 mm nominal bore
2122.86.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge :-Concealed work, including cutting chases and making good the walls etc. :-20 mm nominal outer dia Pipes
2222.84-Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
234.14.1-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out
2422.81.1-Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :-100 mm dia
2522.3.1-Providing and fixing white vitreous chinaware wash basin including making all connections but excluding the cost of fittings :-Flat back wash basin of size 630x450 mm
269.57.3-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.150 mm diameter
279.58.5.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expa
2823.8.12-Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etcincluding fixing with brass screws and washers.
2922.24.1-Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :-W.C. pan with ISI marked white solid plastic seat and lid
306.14.1-1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)Details of cost for 1 cumMATERIAL:- (B0019+B0021+CA008+B0036+CA009+B0029+CA015)LABOUR:- (LB032+LB008+LB002+PM001+PM009+LS004)
319.14.1-Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished n
324.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as di
336.16-Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the
3433.6.1.1-TUBEWELLS :-Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. All types of soil300 mm dia
3523.8.11.7-Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.step type Fan Regulator 2 modules 300 watt
3623.8.10.6-Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.12 Modules
376.15.1-Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of
386.1.1-1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)Details of cost for 1 cumMATERIAL:-(B0019+B0021+CA008+B0036+CA009+B0029+CA015)LABOUR:- (LB032+LB008+LB002+PM001+PM009+LS004)
3913.21.1-Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with P
4010.50.1-Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of c
4121.84.1-M. MASONRY CHAMBERS :- Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design :- Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping
4210.1-Providing and laying of base course of floors consisting of 100 mm thickcement1:8:16and100mmsandor stone filling.
4310.63.1-Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar
4422.106.1-Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. :-15 mm nominal bore
4510.7-Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4
4611.57-Providing & laying average 6mm thick POP Coatingon walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge.
4722.86.3-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge :-Concealed work, including cutting chases and making good the walls etc. :-25 mm nominal outer dia Pipes
4822.86.4-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge :-Concealed work, including cutting chases and making good the walls etc. :-32 mm nominal outer dia Pipes
4922.98.2-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :-20 mm nominal bore
5022.98.5-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :-50 mm nominal bore
5132.43.1-Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m Kas per ASTM 518:1991,in true horizontal level suspended on inter-locking metal powder coatedT-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black),comprising ofmain-Trunners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-Tof size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge :- With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
5222.50.1.2.1-Providing and fixingpartitions for different type of urinals.:-Vitreous Chinaware Partition plate:-Large size 835mm x 355 mm:-White
5322.98.3-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :-32 mm nominal bore.
5422.209-Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
5523.3.6.2-Wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.1 run of Size 2.50 Sqmm(1.1.80mm)
5622.211-Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
5711.5.3-12 mm cement plaster of mix :- 1:4 (1 cement: 4 fine sand)
5823.8.10.1-Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.1 & 2 Modules including combined plate for Telephone and data
5921.87.1.1-Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thickcement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge :- Single road gully chamberSize: 610mm x 457mm x 800mm
6022.100.3-Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : -25 mm nominal bore
6122.15-Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
6222.16-Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint
6333.12-Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
6423.8.4-Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
6523.8.11.10-Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.Blanking plate
6633.17.3-Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
6723.8.10.2-Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.3 Modules
6833.15-Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
6933.13-Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
7022.17.1-Providing and fixing 40mm i/d chromium plated trap with chromium plated pipe to wall with walflange completed for use with sinks:-With Bottle Trap (Indian make)
7123.8.11.5-Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.15 amp 6 pin Socket
7223.8.11.3-Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.15 amp 1 way switch
7323.3.5.2-Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B
7423.3.6.1-Wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.1 run of Size 1.50 Sqmm(1/1.40mm)
7523.8.10.3-Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.4 Modules
7623.6.6.1-Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.MS Pipe of 20 mm dia.
7723.3.4.3-Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group C
7823.3.4.1-Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group A
7923.3.4.2-Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group B
8023.22.6.2-Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.DP RCCB 30ma sensitivity , 40 A
8123.22.5.1-Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:-6 amp. to 32 amp Single Pole
8222.98.4-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :-40 mm nominal bore
8322.212.1.2-Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. :-C.P Brass :-Two Way
8422.109-Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
8522.10.1.1-Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :-Kitchen sink with drain board :-510x1040 mm bowl depth 250 mm
8620.62.1-Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge :- 200 mm i/d
8723.3.5.1-Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group A
8817.22.2-Water Bound Macadam Grading I with screening Type \"A\":- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled stee
8912.98.2-Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete ::-250x16 mm
9011.68.1-Applying priming coat :-With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
9111.5.4-12 mm cement plaster of mix :- 1:6 (1 cement: 6 fine sand)
9223.3.1.2-COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group B
9322.86.1-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge :-Concealed work, including cutting chases and making good the walls etc. :-15 mm nominal outer dia Pipes
9422.26.5-Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :-Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern
9522.214-Providing and fixing in position best Indian make C.P. brass Tumbler cum Tooth Brash holder fixed in with rawl plugs with C.P. brass screws and complete including cutting and making good the walls etc.
9623.3.1.1-COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group A
9723.22.4.3-Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.SPN DBDouble Door 12 way ( 2 incoming and 10 outgoing)
9822.107.1-Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. :-15 mm nominal bore
9923.22.4.2-Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.SPN DBDouble Door 8 way ( 2 incoming and 6 outgoing)
10022.181-LOFT AND TERRACE WATER TANKSProviding and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
10121.94.4-Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described initem No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge :- 250mm i/d
10211.71.1-Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade :- Two or more coats on new work
10311.65.1-Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. :- Two or more coats on new work
10410.59-Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm
10521.84.3-M. MASONRY CHAMBERS :- Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design :- Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab)Note: Normally inspection chambers of 450 mm x 450mm and 450mm x 600 mm should be constructed. In very exceptional cases where connections cannot be accommodated in 450 mm X 600 mm size inspection chamber of 600 mm x 900 mm be adopted.
10613.41-Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bo
10713.21.2-Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanized sheet (Base steel as per IS 513) with zinc of 120 gm/sqm steel sheet pre coated (as per approved colour) with P
10812.36.1-Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face ven
10912.20.2-Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568, for doors, windows and clerestory win
11011.95.1-Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
11111.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : :- 1:4 (1 cement: 4 fine sand)
11211.58-Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour char
11310.51-Providing and fixing granite stone in all shades 15mm to 18 mm thickin skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry
11421.90.4.1-Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surfacewhererequired, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge :- On 200 mm internal diameter pipe sewer :- for 1.80 meters depth below ground level
11521.102.1.2-Providing , lowering, laying, aligning, cutting (cut surface to be finished uniformly), jointing with coupling and EPDM rubber rings marked with IS: 5382 and testing, AC pressure sewerage and drainage pipes manufactured with Mazza process as per IS 6908:1991 and specials into trenches for all levels/depths including carriage, loading/ unloading, stacking, handling, rehandling etc. complete in all respects to the satisfaction of the Engineer in charge (Rates are inclusive of couplers, EPDM rubber rings and specials but exclusive of excavation and refilling) :-Class I (Ultimate load capacity 60KN/sqm) :- 150mm i/d
11621.102.1.1-Providing , lowering, laying, aligning, cutting (cut surface to be finished uniformly), jointing with coupling and EPDM rubber rings marked with IS: 5382 and testing, AC pressure sewerage and drainage pipes manufactured with Mazza process as per IS 6908:1991 and specials into trenches for all levels/depths including carriage, loading/ unloading, stacking, handling, rehandling etc. complete in all respects to the satisfaction of the Engineer in charge (Rates are inclusive of couplers, EPDM rubber rings and specials but exclusive of excavation and refilling) :-Class I (Ultimate load capacity 60KN/sqm) :- 100mm i/d
11717.5.3-Compacting Original Ground:- Compaction of Earthwork:-Compaction of & preparation of sub grade including loosening, levelling of earth 225 mmm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with r
11813.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.:-In gratings, frames, guard bar, ladder, railings, brackets,
11911.14-15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
12010.77-Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006)
121Add Contigency

AI Tender Summary

OUR REF NO 31566975
AUTHORITY Local Bodies
TENDER VALUE 76.05 Lakhs
LAST DATE 05-04-2022
Authority
Authority Name Municipal Corporation
Work Description Providing Of Fixing Of Hall Room Toilet In New General Choupal At Beholi Road Mc Samalkha Providing Of Fixing Of Hall Room Toilet In New General Choupal At Beholi Road Mc Samalkha
Basic Detail
Tender No 1/22.03.22
Bidding Type Tender
Location
City samalkha
State Haryana
Key Dates
Publish Date 22 Mar 2022
Submission Date 05 Apr 2022
Open Date 06 Apr 2022
Finance
Tender Value 76.05 Lakhs
Tender Fee 5000
EMD 1.52 Lakhs
Exemption Not Available
Document List
BOQ_280917.xls
Tendernotice_1.pdf
7272d5a7-f443-40d1-bee0-46e763a9df5e.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 22, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 05, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 06, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_280917.xls

pdf

Tendernotice_1.pdf

html

7272d5a7-f443-40d1-bee0-46e763a9df5e.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders