Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #31523887

Internal Electrification Work Of The Proposed Two Storied Cfc Building At Leather Good Park In Clc, Bantala, South 24 Pargana.

Issued by Local Bodies · bantala, West Bengal
Tender Value
14.96 Lakhs
Estimated cost
Bid Submission
01 Apr 2022
0 days left
EMD
29950
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bantala → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Internal Electrification Work Of The Proposed Two Storied Cfc Building At Leather Good Park In Clc, Bantala, South 24 Pargana.

BOQ

Name of Work:Internal electrification work of the proposed two storied ‘ CFC Building’ at Leather good park in CLC, Bantala, South 24 Pargana.
Sl. No. Item Description
1Supply and fixing of LT panel comprising with 630 A ACB incomer , different type outgoing feeder including 3 nos lighting load feeder along with star delata or DOL starter as per technical specification and direction of EIC.
2Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x100mmx65mm inspection box,making earthing attachment, painting the MS box and mending good the damages to original finish .Average run 8 meter .
3Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish.
4On Board
5Average run 4.5 mtr
6Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required.
72 x 1.5 sqmm X 1.5 sqmm ECC
82 x 2.5 sqmm X 1.5 sqmm ECC
92 x 4 sqmm X 2.5 sqmm ECC
102 x 6 sqmm X 4 sqmm ECC
11Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite /Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
12175 mm X 100 mm X 65 mm.
13150 mm X 100 mm X 65 mm.
14Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
15Supply & Fixing 240 V, 16/20 A plug socket (Brandapproved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
16Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
17Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending gooddamages to building works.
18on board
19Average rubn 3 mtr
20Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
214 module
226 module
2312 Module
24Supply & Fixing 240 V 16 A modular type switch (Brand approved by EIC)on GI Modular type switch board having top cover plate and making necessary connections as required.
25Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
26Supply & Fixing Modular type RJ45 sitable for CAT6 cable (Brand approved by EIC) on existing PVC board and top cover plate on wall and making necessary connections as required.
27Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) on existing GI Modular board having top cover plate and making necessary connections as required.
28Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
29Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
30Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
31Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
3223 cm (9 inch)
33Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
34Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary conection.
35Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C-Curve) in SSenclosure fixed on wall and cecessary conection.
36Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (12way).........
37Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.
38Supplying and fixing of 240/415 V MCB , TP 63 A,of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
39Supplying and fixing of 240/415 V MCB , SP 6-32 A,of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
40Supplying and fixing double door Horizontal TPN MCB Distribution board (8 way) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
41Incomer FP isolator 40 A make Legrand
42Outgoing TP MCB 63 Amake legrand
43Outgoing SPMCB 6-32 Amake legrand
44Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
45Incomer DP isolator 32 a vmake legrand
46Outgoing SP MCB 6-32 A , make -Legrand
47Supply of AL armoured cable of following size
483.5 core 95 sqmm
493.5 core 35 sqmm
50Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
51Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting.
52Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
53Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. size 200 X 50 X 1.25 mm (18SWG).
54Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
55upto 50 sqmm
56from 70 sqmm to 150 sqmm.
57Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
584 core 6 sqmm
593.5 core 35sqmm
603.5 core 95 sqmm
61Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
624 core 6 sqmm
633.5 core 35sqmm
643.5 core 95 sqmm
65Excavation of soil for installation of Earth Electrode and filling & ramming.(for soft soil)
66Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(By TATA GI )
67Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
68Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
69Added cess @ 1 %

AI Tender Summary

OUR REF NO 31523887
AUTHORITY Local Bodies
TENDER VALUE 14.96 Lakhs
LAST DATE 01-04-2022
Authority
Authority Name Kolkata Metropolitan Development Authority
Work Description Internal Electrification Work Of The Proposed Two Storied Cfc Building At Leather Good Park In Clc, Bantala, South 24 Pargana.
Basic Detail
Tender No E(E/M)/JNNURM-I/KMDA /2W-06/04
Bidding Type Tender
Location
City bantala
State West Bengal
Key Dates
Publish Date 17 Mar 2022
Submission Date 01 Apr 2022
Open Date 04 Apr 2022
Finance
Tender Value 14.96 Lakhs
Tender Fee Ref. Documents
EMD 29950
Exemption Not Available
Document List
a2e33be5-d882-4b9c-960c-7d5821253b2f.html
BOQ_722047.xls
Docs6.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 17, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 01, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 04, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a2e33be5-d882-4b9c-960c-7d5821253b2f.html

xls

BOQ_722047.xls

pdf

Docs6.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders