Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine For 3 Yrs Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine F, kalamasserry-Kerala

Kerala Industrial Infrastructure Development Corporation-KINFRA has published Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine For 3 Yrs Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine F. Submission Date for this Tender is 31-03-2022. Water Supply Project Tenders in kalamasserry Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

31514649
Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine For 3 Yrs Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine F
Open Tender
Indian
Kerala
kalamasserry
31-03-2022

Tender Details

Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine For 3 Yrs Operation Maintenance And Upkeep Of The 6 Mld Water Supply Scheme And Associated Electro Mechanical Equipment And Routine For 3 Yrs

Key Value

Document Fees
INR 2950 /-
EMD
INR 50000.0 /-
Tender Value
INR 90.93 Lakhs /-

BOQ Items

Name of Work: Operation, maintenance and Upkeep of the 6 MLD Water Supply Scheme & Associated Electromechanical equipment and Routine and Preventive Maintenance of DG sets, pumps & motors and water distribution network of KINFRA Hi-Tech Park, Kalamassery for a period of3 years.
Sl. No. Item Description
1Engaging qualified, experienced Plant operator (WTP) 1each /shift (Male)-(Total - 1 shift per day)
2First Year
3Second Year
4Thrid Year
5Engaging qualified, experienced Pump Operator – for Intake well site– 1 each/ shift (Men)- 1 shift/day
6First Year
7Second Year
8Thrid Year
9Engaging qualified, experienced Helpers (male) – for WTP 1 each / shift (Men)- 3shifts perday
10First Year
11Second Year
12Thrid Year
13Sweepersforsweeping andcleaningoffloors,walls, roofsetcofWTP. (Half day)
14First Year
15Second Year
16Thrid Year
17Engaging qualified, experienced Chemist (WTP - Hi-Tech)
18First Year
19Second Year
20Thrid Year
21Engaging qualified, experienced Pipeline Fitter for Intake well site & WTP (Men)
22First Year
23Second Year
24Thrid Year
25Engaging qualified experienced Electrician for electrical repair works (Men)
26First Year
27Second Year
28Thrid Year
29Engaging qualified, experienced Plumber/ Fitter - forO & M activities at Hi-Tech, WSS (Men)
30First Year
31Second Year
32Thrid Year
33EngagingMen labourers as and when required for work such as dewatering trenches manually , cleaning water weeds in water bodies infront of intakes etc,and Miscellaneousworkas per the directions of KINFRA Hi-Tech Park.
34First Year
35Second Year
36Thrid Year
37Lifting and carefully removing RCC / heavy duty CI cover slabs of manhole chambers for sluice valves, air valves, scour valves etc. of the pipelines removing the silt deposit, if any,includingcleaning the body of the valves chamber etc. and replacing the RCC cover slabs after the work carefully without any damage including seating the slabs in cm 1:5 to lines and levels etc.
38First Year
39Second Year
40Thrid Year
41Earth work excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm or on plan) , including dressing of sides and ramming of bottoms, lift upto 1.5m , including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of soil
42First Year
43Second Year
44Thrid Year
45Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
46First Year
47Second Year
48Thrid Year
49Filling with contractors own gravelly soil /sandincluding loading, unloading, and stacking for measurements and filling in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50First Year
51Second Year
52Thrid Year
53Cutting tarred surface of the road and disposal of debris as per direction of KINFRA Hi-Tech Park
54First Year
55Second Year
56Thrid Year
57CuttingDI pipes perpendicular to the axis of the pipe in trenches using DI pipe cutters wherever required without causing damages to the pipe for 350mm DI
58First Year
59Second Year
60Thrid Year
61CuttingDI pipes perpendicular to the axis of the pipe in trenches using DI pipe cutters wherever required without causing damages to the pipe for 300mm DI
62First Year
63Second Year
64Thrid Year
65CuttingDI pipes perpendicular to the axis of the pipe in trenches using DI pipe cutters wherever required without causing damages to the pipe for250 mm DI
66First Year
67Second Year
68Thrid Year
69CuttingDI pipes perpendicular to the axis of the pipe in trenches using DI pipe cutters wherever required without causing damages to the pipe for 200mm DI
70First Year
71Second Year
72Thrid Year
73CuttingDI pipes perpendicular to the axis of the pipe in trenches using DI pipe cutters wherever required without causing damages to the pipe for 150mm DI
74First Year
75Second Year
76Thrid Year
77Dismantling the damagedD.I./ C.I pipes after taking out the pipes manually/ mechanical means breaking lead caulked joints / removing and stacking rubber rings as the case may be of pipes and specials at site within 50 m lead as per the direction of engineer in chargefor 350mm DI
78First Year
79Second Year
80Thrid Year
81Dismantling the damagedD.I./ C.I pipes after taking out the pipes manually/ mechanical means breaking lead caulked joints / removing and stacking rubber rings as the case may be of pipes and specials at site within 50 m lead as per the direction of engineer in chargefor 300mm DI
82First Year
83Second Year
84Thrid Year
85Dismantling the damagedD.I./ C.I pipes after taking out the pipes manually/ mechanical means breaking lead caulked joints / removing and stacking rubber rings as the case may be of pipes and specials at site within 50 m lead as per the direction of engineer in chargefor 250 mm DI
86First Year
87Second Year
88Thrid Year
89Dismantling the damagedD.I./ C.I pipes after taking out the pipes manually/ mechanical means breaking lead caulked joints / removing and stacking rubber rings as the case may be of pipes and specials at site within 50 m lead as per the direction of engineer in chargefor 200mm DI
90First Year
91Second Year
92Thrid Year
93Dismantling the damagedD.I./ C.I pipes after taking out the pipes manually/ mechanical means breaking lead caulked joints / removing and stacking rubber rings as the case may be of pipes and specials at site within 50 m lead as per the direction of engineer in chargefor 150mm DI
94First Year
95Second Year
96Thrid Year
97Laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 (excluding cost of pipe) for 350mm DI
98First Year
99Second Year
100Thrid Year
101Laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 (excluding cost of pipe) for 300mm DI
102First Year
103Second Year
104Thrid Year
105Laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 (excluding cost of pipe) for 250 mm DI
106First Year
107Second Year
108Thrid Year
109Laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 (excluding cost of pipe)for 200mm DI
110First Year
111Second Year
112Thrid Year
113Laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 (excluding cost of pipe))for 150mm DI
114First Year
115Second Year
116Thrid Year
117provindingjoints to CentrfuifugallyDI pipes including testing of jointsby Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead and jointing materialsfor 350mm DI
118First Year
119Second Year
120Thrid Year
121provindingjoints to CentrfuifugallyDI pipes including testing of jointsby Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead and jointing materials) for 300mm DI
122First Year
123Second Year
124Thrid Year
125provindingjoints to CentrfuifugallyDI pipes including testing of jointsby Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead and jointing materials)for 250 mm DI
126First Year
127Second Year
128Thrid Year
129provindingjoints to CentrfuifugallyDI pipes including testing of jointsby Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead and jointing materials)for 200mm DI
130First Year
131Second Year
132Thrid Year
133provindingjoints to CentrfuifugallyDI pipes including testing of jointsby Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead and jointing materials)for 150mm DI
134First Year
135Second Year
136Thrid Year
137Providing flanged joints toC.I./ D.I. pipes and specials, including testing of joints excluding cost of jointing materials for 350mm DI
138First Year
139Second Year
140Thrid Year
141Providing flanged joints toC.I./ D.I. pipes and specials, including testing of joints excluding cost of jointing materialsfor 300mm DI
142First Year
143Second Year
144Thrid Year
145Providing flanged joints toC.I./ D.I. pipes and specials, including testing of joints excluding cost of jointing materials for 250 mm DI
146First Year
147Second Year
148Thrid Year
149Providing flanged joints toC.I./ D.I. pipes and specials, including testing of joints excluding cost of jointing materials for 200mm DI
150First Year
151Second Year
152Thrid Year
153Providing flanged joints toC.I./ D.I. pipes and specials, including testing of joints excluding cost of jointing materials for 150mm DI
154First Year
155Second Year
156Thrid Year
157Providing push on joints to DI pipes including testing of joints using rubber rings for 350mm DI
158First Year
159Second Year
160Thrid Year
161Providing push on joints to DI pipes including testing of joints using rubber rings for 300mm DI
162First Year
163Second Year
164Thrid Year
165Providing push on joints to DI pipes including testing of joints using rubber rings for 250 mm DI
166First Year
167Second Year
168Thrid Year
169Providing push on joints to DI pipes including testing of joints using rubber rings for 200mm DI
170First Year
171Second Year
172Thrid Year
173Providing push on joints to DI pipes including testing of joints using rubber rings for 150mm DI
174First Year
175Second Year
176Thrid Year
177ProvidingMechnical Joint using Drum Collar for 350mm- 200mm D.I. pipes and specials, including testing of joints excluding cost ofDrum Collar jointing materials:
178First Year
179Second Year
180Thrid Year
181Dismantling the existing sluice valvesfrom the pipeline by cutting and removing the rusted nuts and bolts, disassembling the valve using necessary chain pulley block, taking out the spindle, shutter etc., cleaning the shutter, shutter groove with sharp chisel and Emrine cloth, applying grease and removing old packing etc and resetting and assembling the valve with new packing leather and gland packing rope, nuts and bolts including servicing, greasing and resetting the valve in the pipeline.
182First Year
183Second Year
184Thrid Year
185Dismantling the existing foot valveof motor/pumps upto 49 HP, taking it out from the tank using necessary chain pulley block, and rectifing leakages including replacement of flaps and resetting the valveand relaying into the tank
186First Year
187Second Year
188Thrid Year
189Rectification of leakages/breakage in 200 mm - 150mm PVC pipelinesby exposing the pipeline, cutting and dismantling the damaged pipe, laying and jointing new pipe bit using CID joint/coupling, solvent cement after making socket at both the ends of pipe if necessary etc, including protecting the sides of the trenches, bailing out water, controlling the valves, testing the pipe line, back filling etc as per the direction of Engineer - in - charge,excluding earthwork excavation and filling which will be paid seperately.(Material Cost not include)
190First Year
191Second Year
192Thrid Year
193Rectification of leakages/breakage in 150 mm - 110 mm PVC pipelinesby exposing the pipeline, cutting and dismantling the damaged pipe, laying and jointing new pipe bit using CID joint/coupling, solvent cement after making socket at both the ends of pipe if necessary etc, including protecting the sides of the trenches, bailing outwater, controlling the valves, testing the pipe line, back filling etc as per the direction of Engineer - in - charge,excluding earthwork excavation and filling which will be paid seperately.(Material Cost not include)
194First Year
195Second Year
196Thrid Year
197Rectification of leakages in 110 mm - 40mm PVC pipelines by exposing the pipeline, cutting and dismantling the damaged pipe, laying and jointing new pipe bit using CID joint/coupling, solvent cement after making socket at both the ends of pipe if necessary etc, including protecting the sides of the trenches, bailing outwater, controlling the valves, testing the pipe line, back filling etc as per the direction of Engineer - in - charge,excluding earthwork excavation and filling which will be paid seperately.(Material Cost not include)
198First Year
199Second Year
200Thrid Year
201Loading heavy dismantled parts of components, pipes and specials and other materials etc. carefully into lorries and transporting the sameaupto 5 km distance and unloading and stacking the materials at the destination including hire to lorry, wire rope, pully etc.
202First Year
203Second Year
204Thrid Year
205Loading heavy dismantled parts of components, pipes and specials and other materials etc. carefully into lorries and transporting the sameabove 5 km distance upto 10km and unloading and stacking the materials at the destination including hire to lorry, wire rope, pully etc.
206First Year
207Second Year
208Thrid Year
209Loading heavy dismantled parts of components, pipes and specials and other materials etc. carefully into lorries and transporting the sameabove 10km distance upto 20km and unloading and stacking the materials at the destination including hire to lorry, wire rope, pully etc.
210First Year
211Second Year
212Thrid Year
213Loading heavy dismantled parts of components, pipes and specials and other materials etc. carefully into lorries and transporting the sameabovebeyond 20km distanceand unloading and stacking the materials at the destination including hire to lorry, wire rope, pully etc.
214First Year
215Second Year
216Thrid Year
217Empty Chlorine cylinder to TCC and refilling chlorine cylinder (18 km) including loading & unloading , stacking at both ends. ( upto 3 cylinders in one load)
218First Year
219Second Year
220Thrid Year
221Dismantling carefully motor of 75 HP vertical turbine pump set from the stool without damaging the motor by detaching cable connection, earthing, couplers etc… and taking out from the pump house using necessary chain pulley blocks and refixing the same after reparing (Repair Cost not Included)
222First Year
223Second Year
224Thrid Year
225Dismantlingcarefully motor of 75 HP vertical turbine pump set from the stooland store in the pump housewithout damaging the motor by detaching cable connection, earthing, couplers etc and Dismantling carefully the 75 HPV T pump, without damaging the same by detaching the column pipe, driving shaft, spider bushes, impellers, bearing / bushes etc... and taking out from the pump house using necessary chain pulley blocks and refixing the same after reparing.(Repair Cost not Included)
226First Year
227Second Year
228Thrid Year
229Dismantling carefully the motor of various capacityfrom25HP upto /or 60 HP from the bed of pump set / blowers by detaching cable connections, couplers, foundation bolts etc... complete without damages to the same and taken out from pump house using necessary chain pulley blocks and refixing the sameafter reparing
230First Year
231Second Year
232Thrid Year
233Dismantling carefully the motor of various capacityfrom5 HP upto 24HP from the bed of pump set / blowers by detaching cable connections, couplers, foundation bolts etc... complete without damages to the same and taken out from pump house using necessary chain pulley blocks and refixing the sameafter reparing
234First Year
235Second Year
236Thrid Year
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail